vistaHD user manual
Contents
1. The FP 9 and the FP 10 have identical manual control systems The FP 10 is simply a desktop version of the FP 9 The BT 2 is as are all genetics modules controlled using a set of MENUS Each of these menus contains up to 3 parameters that are adjusted using the rotary digipots The Menus define all of the adjustable operational parameters in the BT 2 Pressing the rotary digipots brings the parameter to its default value if it has one Device selection is done using the device select switches which when pressed will offer the name of the device in the LCD Window Modules can be acquired and then de acquired using the set up switch For a full description of the operation philosophy of the geNETics system refer to the geNETics User Guide section Operation of the flexiPanel A full list of the Menus and their functions are given in section 3 of this chapter 3 2 Automation Control of the BT 2 Automation of the geNETics products is achieved via an RS422 port This port is marked RS422 on the rear of a flexiBox For the port to work a flexiPanel MUST be connected locally on the front of the flexiBox Automation control of the BT 2 can be done using two protocol methods e geNETics Automation Protocol e PresTX Automation Protocol Genetics protocol is described in detail in the GeNETics User Guide section titled Automation Protocol on the geNETics Platform The menu list in section 3 of this chapter contains the
2. el Function This will activate the Time code trigger The trigger will activate at Trig 1 timecode and de activate at Trig 2 timecode O OFF No trigger can occur 1 GO Triggers are enabled 2 Done 1 Trigger 1 is assumed past and so Trig 2 will de activate only This may be read by automation to ensure trigger 1 has occurred When this button is pressed to Green The Three line display in the window indicates the two eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com minutes 86 Trigger 1 Activate Seconds and frames 87 Back Level A 0323 Level B 0359 Level A 0359 Level B 024 or 29 for 525 N A options which can be changed by adjusting the two rotary digipots A and B A determines the Hours at which the trigger will activate B determines the Minutes at which the trigger will activate When this button is pressed to Green The Three line display in the window indicates the two options which can be changed by adjusting the two rotary digipots A and B A determines the Seconds at which the trigger will activate B determines the Frames at which the trigger will activate Pressing this button will take the user back to the utils menu Menu 88 91 Time code
3. Menu Num Heading Automation Function 104 MEM4 1 Recall Pressing this will recall Memory number 4 105 MEM5 1 Recall Pressing this will recall Memory number 5 106 MEM6 1 Recall Pressing this will recall Memory number 6 107 BACK none Go To the Util Menus Menus 108 111 Save memory 133 menus NEXT PREV to navigate Menu Num Heading Automation Function 108 SAVE 1 Save Pressing this will Save Memory MEM1 number 1 109 SAVE 1 Save Pressing this will Save Memory MEM2 number 2 110 SAVE 1 Save Pressing this will Save Memory MEM3 number 3 111 BACK none Go To the Util Menus Menus 112 115 Save memory 4 gt 6 menus NEXT PREV to navigate ps eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menu Num Heading Automation Function 112 SAVE 1 Save Pressing this will Save Memory MEM4 number 4 113 SAVE 1 Save Pressing this will Save Memory MEM5 number 5 114 SAVE 1 Save ee this will Save Memory MEM6 number 6 115 BACK none Go To the Util Menus Menus 116 119 Software version menu PREV to navigate _ Menu Num Heading Automation Function 116 Info none Information 117 Info none Information 118 none none Software Vers
4. Output 1b GPO1b Isolated Relay closure Activates remote start lan lk a i e 13 General Purpose Input 1 GPI1 Pull to Ground to activate on screen display 9 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 14 Not Used 15 Not Used 16 Not Used 17 Not Used 18 Not Used 19 Not Used 20 Not Used 21 Time Code Input LTC Balanced Time Code Input LTC Balanced 23 Not Used 24 Not Used 2 4 Connecting Panels to the BT 2 The BT 2 may be operated using a FP 9 Flexipanel locally mounted For a more operational environment the BT 2 may be supplied with a desk mounting FP 10 unit For detailed information on connecting remote panels refer to the section Connection of Remote Panels to a flexiBox in the geNETics Hardware Installation Guide Below is shown a typical system consisting of an BT 2 in a flexiBox controlled by a remote FP 9 IO eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com eyeheight Connect Pins 1 2 4 7 9 from chassis to panels 1 1 Use twisted pair AES Digital Audio cable for pins 2 and 7 Pins 1 4 9 carry power 0 5 Amp 13V
5. danger area This Switches on and off the currently selected area Pressing the Red switch next to this one and adjusting the rotary digipots with the lighted green LED s chooses the Selected area When this button is pressed to Green The Three line display in the window indicates the three options which can be changed by adjusting the three rotary digipots A B and C A determines the basic Function e Selects Safe Action option e Selects Safe Caption option e Selects Digital Edge option Selects the An Edge option eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Digipot B 4 3 16 9 16p4 3 16p149 43p16 9 0 gt 4 Variable 2 Digipot C Thin Thick Shade Black 0 gt 3 Variable 3 B Determines the Screen Format Standard 4 3 Screen Standard 16 9 Screen 16 9 Shoot to protect 4 3 16 9 Shoot to protect 14 9 e 4 3 Shoot to protect 16 9 Not available in 525 C Determines the Style of Indicate e Thin White lines are used e Thick White lines are used e Shade is used for danger area e Black is used for danger area Menu 84 87 Time code external trigger Press NEXT button for TRIG 2 Menu Num 84 85 Heading Time code trigger activation Trigger 1 Activate Hours and Automation 032
6. data information for the protocol PresTX Automation Protocol is used only for the PresTX Presentation Mixer and channel branding system In this case an AU 2 Automation card is also required Refer to the PresTX Product manual On most flexiBoxes later than 1 10 02 the RS422 port has been replaced by a D Bus Port The D Bus port is for High Speed data transfer and is not used for serial control In order to achieve serial control of any products on an I Bus network Eyeheight Ltd have developed a RS232 gt bus converter dongle DG 9 which enables greater flexibility of products on the I Bus network whilst using the same protocols as the RS422 port Please refer to the User guide for the DG 9 eyeheight dongle and set up software le eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 3 3 Operational Menus for the BT 2 Menu 00 03 Top level controls Menu Num 0 Heading Set Up System On Screen Display Format Utilities View the Timecode on the LCD display Automation N A N A N A N A Function Pressing this will take you to further set up mode options menu 60 Pressing this button will take you to further on screen display options menu 44 Pressing this button will take you to system extras such as the safe area generator and
7. external trigger Press PREV button for TRIG 1 Menu Num Heading 88 none 89 Trigger 2 De activate Hours and minutes Automation N A Level A 0323 2e2 Function When this button is pressed to Green The Three line display in the window indicates the two options which can be changed by adjusting the two rotary digipots A and B A determines the Hours at which the trigger will de activate eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 90 91 Trigger 1 De activate Seconds and frames Back Level B 0359 Level A 0359 Level B 0424 or 29 for 525 N A Menu 92 95 Time code view Menu Num 92 93 94 Heading Current TC hours and VITC LTC indication Current TC hours and VITC LTC indication Current TC hours and VITC LTC indication Automation 0323 read only 0359 read only 0359 read only 23 B determines the Minutes at which the trigger will de activate When this button is pressed to Green The Three line display in the window indicates the two options which can be changed by adjusting the two rotary digipots A and B A determines the Seconds at which the trigger will de activate B determines the Frames at which the trigger
8. the timecode trigger facility menu 76 Pressing this button will cause the display to show the current timecode NOTE MENUS FROM 0543 ARE NOW HIDDEN THIS HAS BEEN DONE FOR AUTOMATION TO REMAIN COMATIBLE WITH VERSIONS OF SOFTWARE FROM 2 5 AND BELOW THE MENUS WILL STILL EXIST FOR AUTOMATION PURPOSES BUT ARE NO LONGER DOCUMENTED Menu 44 47 On Screen display control 13 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menu Num Heading Automation Function 44 On Screen N A display position Pressing this button will Take you to the on screen display positioning menus menu 48 45 On Screen N A display size 46 On Screen N A display colour Pressing this button will Take you to the on screen display character size menus menu 52 Pressing this button will Take you to the on screen display character colour menus menu 56 47 BACK N A Pressing this button will take the user back to the main top menu Menu 48 51 On screen display position control 14 Menu Num Heading Automation Function 48 Horizontal ARE In Horizontal Luma Pixels Position of 0 Start at LHS burnt in 719 Line at R
9. will de activate Pressing this button will take the user back to the utils menu Function This is the current Hours display of the input timecode This is the current Minutes display of the input timecode This is the current Seconds display of the input timecode eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 95 Back N A Pressing this button will take the user back to the top menu Menu 96 99 NOT USED Menu Num Heading Automation Function 96 Not used 97 Not used 98 Not used 99 Not used Menus 100 103 Memory 133 menus NEXT to navigate Menu Num Heading Automation Function 100 MEM1 1 Recall Pressing this will recall Memory number 1 User Names can be programmed in to the memories using a keyboard See geNETics User guide section Giving product Memories names Pressing this will recall Memory number 2 102 MEM3 1 Recall Pressing this will recall Memory number 3 103 BACK none Go To the Util Menus 101 MEM2 1 Recall DA eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menus 104 107 Memory 436 menus NEXT PREV to navigate
10. HS display 49 Vertical In vertical lines Position of N 28 Start at Line Top burnt in 28232 in 525 232 272 Line at Bottom display 50 N A none 51 Back N A Pressing this button will take the user back to the On screen menu options eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menu 52 55 On screen display character size control Menu Num Heading Automation 52 Horizontal 654i Size of burnt in display 53 Vertical ase Size of burnt in display 54 N A 55 Back N A Function Each unit adds an extra pair of luma pixels to the width of a chr pixel Each chr is 8 pixels wide Size0 16 luma chr width Size1 32 luma chr width Size2 48 luma chr width And so on up to 31 Each unit adds an extra pair of lines to the height of a pixel Each chr is 8 pixels high Size0 16 line chr height Size1 32 line chr height Size2 48 line chr height And so on up to 31 None Pressing this button will take the user back to the On screen menu options Menu 56 59 On screen display character colour control Menu Num Heading Automation 56 Text Colour of On a screen characters 5 Function eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Tele
11. ITC are switched OFF allowing the good input VITC to pass For this to occur the Reader MUST be set to AutoLTC See menu 66 Pressing this button will take the user back to the set up mode options Function Menu Num Heading 32 Info N A 33 Info N A 34 GPI Enable a 0 gt 1 Automation This enables the character on screen display to be switched on and off remotely using GPI 1 A eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 35 Back N A Menu 76 79 Clip control menu Ground on GPI 1 will switch the display off Pressing this button will take the user back to the set up mode Menu Num Heading Automation 76 Safe area N A generator 77 Time code N A external trigger 78 Memories N A 79 Back N A Function Pressing this will take you to the safe area generator control set up menus menu 80 Pressing this will take you to the TC trigger set off an external event set up menus menu 84 Pressing this will take you to the TC memories menu 100 Pressing this button will take the user back to the utils menu Menu 80 84 Safe Areas Press PREV button to exit Menu Num Heading Automation 80 Safe Area a 1 on off 0 gt 1 Variable 3 81 Area selected by menu 4 19 Function This Switches on and off the currently se
12. ITC conversion 4 different display modes with user selectable screen position size and user selectable character colour and background colour Integral Safe area generator with cursors for 4 3 14 9 and 16 9 formats Remote Character display on off using GPI Timecode Trigger feature enables timed remote control of a user device Reads 25 30 frame timecode with drop frame indication for 525 operation 8 User Memories 5 o N al Ss o N Figure 1 1 The BT 2 colour correction PCB 4 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Box Gen 1 Safe areas VITC ON SCREEN READER DISPLAY amp VITC INSERT Safe areas LTC Input LTC READER GPI INPUT AND GPI REMOTE START INTERFACE Figure 1 2 Block diagram of the BT 2 timecode reader This unit consists of 2 generic Box generators which perform the on screen Safe Area and safe caption generation This leads into a VITC Reader with programmable line selection The VITC reader does full hardware CRCC checking for validity If EITHER of the selected lines is valid the unit will assume that the VITC is valid Alternatively the LTC can be read The LTC reader is software based using a microcontroller and will read up to at least 8x normal speed and down to 1 5 speed The Timecode inform
13. Use cable with a least a 1 amp rating for pins 1 4 9 Cable llength should not exceed 250m I Bus pins 2 amp 7 The I BUS Network requires terminating with 100 Ohms at each extreme end of the network Ensure that this is done either by an external 100 ohm resistor OR ONE Panel Product at each end has the termination set See the Genetics User Guide Under the sections Flexipanel Power I BUS Jumpers For the 4RU Panels see 4RU Panel FP 10 Jumpers for I BUS and 4RU Panel VP 10 SW 10 AP 10 Jumpers for I BUS Alternatively The termination can be set on a Product ie the MW 2 module Information about this is given in this manual Figure 2 2 I Bus Connections and Termination N B From 1 10 02 Eyeheight introduced a change in the flexiBox Chassis Most versions now have two 9 way connectors on the rear labelled I Bus and D Bus The I Bus connector is the same as the previously labelled Can B connector Although a maxiBox is shown in this diagram the same arrangement applies for a flexiBox chassis Il eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 3 Operation 3 1 Manual control of the BT 2 Manual Control of the BT 2 is done using one or more of the following control surfaces e The 1RU FP 9 Flexipanel e The FP10 Desk mounting Panel
14. ation from the VITC or the LTC can be displayed on the 24 chr on screen display The LTC is deemed to be invalid when the LTC reader cannot find a valid LTC header 24 short consecutive transitions The GPI input is used to remotely control the on screen display The remote start output can go on off at programmable timecode points Il Drop Frame indicator The Output on screen timecode reader will indicate drop frame timecode This is only applicable for 30 frame timecode The flag is indicated by a dot between the frames and the seconds instead of a colon l 2 Applications for the BT 2 Applications for the BT 2 include the following e Offline editing in vision time code stamping e General time code reading e Timecode activation of devices 5 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 1 3 Associated Equipment for the BT 2 The BT 2 is a module and requires both a chassis and a control surface to function 1 3 1 Chassis Types e flexiBox is a 1RU chassis The order code is FB 9 This will hold a maximum of 6 BT 2 Modules with Hot Swap redundant PSU option and Hot Swap BT 2 modules e maxiBox is an alternative low cost IRU chassis The order code is MX 9 This also will hold a maximum of 6 BT 2 modules but it has no redundant PSU option and the BT 2 u
15. em with a Flexipanel and that the flexiBox has at least one spare slot for the BT 2 card 2 2 Installing the BT 2 into a flexiBox To install the BT 2 into a flexiBox it is desirable but not necessary to power down the flexiBox Follow these instructions On the rear of the flexiBox are 6 slots for Products Remove any spare blanking plate There are 2 off M2 5 Screws which require unfastening for each blanking plate Slide the Product PCB into the spare slot and firmly push it home Use the two thumbscrews to fasten the unit in place Now refer to the GeNETics User Guide If your system consists of a single flexiBox with a single flexiPanel then refer to the section titled flexiPanel Auto Set up If your system is part of a network with more than one flexiPanel then refer to the section titled flexiPanel Manual Set up This will guide you through acquiring your product as a device on the flexiPanel 2 3 Connecting Video to an BT 2 The BT 2 connections are shown below 8 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com BT 2 Processor Card SDI In SDI Out Remote VITC BITC GP Start LITE Figure 2 1 Connections for a BT 2 module Bu Function of 25w D Type connector General Purpose Output 1a GPO1a Isolated Relay closure Activates remote start General Purpose
16. eyeheight SDI LTC VITC time code reader user manual Table of Contents 1 System OVEINVIOW naeh ee ee 4 1 1 Drop Frame indicator 4444444440nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 5 12 ApplieatisnsT rtbeBT2 sesenee aE EEEa 5 1 3 Associated Equipment for the BT 2 222440ssssnnnnnsnnnnnnnnnnnnnnnnnnnn 6 1 3 1 Chassis Types seen 6 1 3 2 Control SUhaBe seta eisen 6 2 Installation ioniene een ea ters eine 8 2 1 Installation of the BT 2 Pproduet nein 8 2 2 Installing the BT 2 into TEM BOX anne ee 8 23 Connecting Video to an BiH oocniocacasssasansepeoceidenenananacinrncdapiauanadaaaiadonadeds 8 2 4 Connecting Panels to the BT 2 uuumessssssssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 10 3 Operation ee E E E 12 3 1 Manual control of the BI ae 12 3 2 Automation Control of the BT 2 22224444sssnnennnnnnnnnnnnnnnnnnnnnnnnnn nn 12 3 3 Operational Menus for the BT2 une 13 4 Technical AppendiX aus aHa 28 4 1 Technical Specification for the BT 2 22244sssnsnnnnnnnnnnnnnnnnnnnnnn 28 4 2 Jumpering the I BUS CAN BUS Termination 4nnn gt 28 2 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Table of Figures Figure 1 1 The BT 2 colour correction PCB 2 scsicesscasceessecuace
17. ion Information 119 BACK none Go To the Util Menus Menus 120 123 Power on memory menus PREV to navigate Menu Num Heading Automation Function 120 SetAs 1 Set Pressing this will set the current Pow On system set up as the Power on Memory memory default 121 Recall 1 Recall Pressing this will recall The Power on Pow On memory set up in the last menu Memory 122 Total 1 Reset Pressing this will cause a first Birthday Reset of the unit All current memories and settings will be lost 123 BACK none Go To the Util Menus P6 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 27 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 4 Technical Appendix 4 1 Technical Specification for the BT 2 SDI Input 1 270Mbit Serial Digital Video Inputs 75 Ohm Longitudinal Time Differential 6000hm 6dB gt 12dB Reads from 0 2 Code Input gt 8 speed timecode SDI Input Line At least 200 Meters of PSF1 3 Typically 275 Meters Length Number of Outputs 1 Output SDI 270 Mhz SDI Output Jitter The system will add less than 0 2UI to the input Jitter This is only guaranteed on i
18. its 0 VITC Read from VITC Only 1 LTC Read from LTC Only 2 Auto VITC Read from VITC unless the VITC is not valid then read from LTC 3 Auto LTC Read from LTC unless the LTC is not valid then read from VITC Pressing this button will take the user back to the set up mode options Menu Num Heading 68 Select VITC Line numbers Automation Digipot A 6 gt 23 Digipot B 6 gt 23 Function When this button is pressed to Green The Three line display in the window indicates the two options which can be changed by adjusting the two rotary digipots A and B Select VITC Line number 1 Select VITC Line number 2 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 69 LTC reader Offset 0 gt 4 70 VITC 032 Insert O off 1 on 2 Auto 71 Back N A Menu 72 75 GPI enable This will offset the reader by the amount below This is for LTC only 0 2 Fld 1 1 Fld 2 IS OFF 3 1 Fid 4 2 Fld This allows new VITC to be inserted which are driven by the LTC input code This effectively is an LTC to VITC converter OFF No new VITC is inserted ON New VITC are permanently inserted AUTO New VITC are inserted while valid LTC is present If no valid LTC is present and Valid VITC is present then the New inserted V
19. lected area Pressing the Red switch next to this one and adjusting the rotary digipots with the lighted green LED s chooses the Selected area When this button is pressed to Green The Three line display in the window indicates the three options which can be changed by eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 82 83 Safe Area 2 on off Area selected by menu 6 Digipot A S Action S Capt Dig Edge An Edge 0 gt 3 Variable 1 Digipot B 4 3 16 9 16p4 3 16p149 43p16 9 0 gt 4 Variable 2 Digipot C Thin Thick Shade Black 0 gt 3 Variable 3 On Off 0 gt 1 Variable 3 Digipot A S Action S Capt Dig Edge An Edge 0 gt 3 Variable 1 20 adjusting the three rotary digipots A B and C A Determines the basic Function e Selects Safe Action option e Selects Safe Caption option e Selects Digital Edge option e Selects the An Edge option B Determines the Screen Format e Standard 4 3 Screen e Standard 16 9 Screen e 16 9 Shoot to protect 4 3 e 16 9 Shoot to protect 14 9 e 4 3 Shoot to protect 16 9 N Not available in 525 C Determines the Style of Indicate e Thin White lines are used e Thick White lines are used e Shade is used for danger area e Black is used for
20. nits must be factory fitted ais Figure 1 3 flexiBox with flexiPanel fitted 1 3 2 Control Surfaces e flexiPanel is a IRU control surface that fits on the Front of a 1RU flexiBox The order code is FP 9 A FlexiPanel can also be used in conjunction with a miniBox in this case the extra accessory Order code RR 9 will be required e FP 10 is a desk mounting control surface Order code FP 10 eyeheight 6 gt 0 Figure 1 4 FP 10 desktop modular panel 6 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com eyeheight Figure 1 5 FP 9 1RU modular panel 7 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 2 Installation 2 1 Installation of the BT 2 product If this unit is already pre installed in a flexiBox FB 9 or a maxiBox with either a local or a remote panel from the factory then refer to the Hardware Installation Guide which will be enclosed with the system If this unit is pre installed in a miniBox MB 9 then also refer to the Hardware Installation Guide which will be enclosed with the system If this unit has been ordered separately we assume here that you already have a flexiBox syst
21. phone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 57 Background To 0 Black Colour of 1 Blue On screen 2 Red characters 3 Purple 4 Green 5 Cyan 6 Yellow 7 White 58 None N A 59 ka N A Pressing this button will take the user back to the main menu Menu 60 63 System set up options Menu Num Heading Automation Function 60 Set up the None Pressing this will take you to the TC TC reader reader set up menus menu 64 61 Timecode None Pressing this will take you to the TC format format menus menu 68 options 62 Re set up None Pressing this will take you to the GPI enable menu menu 72 63 Back None Pressing this button will take the user back to the top menu Menu 64 67 TC reader options Menu Num Heading Automation Function 64 Enable the 0 No Display I6 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com burnt in display 65 Display mode of burnt in Timecode display 66 Reading Mode Menu 68 71 Timecode set up options Timecode 0 gt 2 0 gt 3 1 Chrs Displayed 2 Chrs Box Display 0 HH MM SS 1 HH MM SS FF 2 HH MM SS FF UU UU UU UU Notes Field Mark UU User B
22. seeeecceseeescuenacesceesieeeeeine 4 Figure 1 2 Block diagram of the BT 2 timecode reader sun44n nn 5 Figure 1 3 flexiBox with flexiPanel fitted uus24242444444BHnnnnnnn anne 6 Figure 1 4 FP 10 desktop modular panel uuussssssnnnnnnnnnnnnnnnnnnnnnnnnnn 6 Figure 1 5 FP 9 1RU modular panel 242444444000nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 7 Figure 2 1 Connections for a BT 2 module 422424444400Rnnnnnn nenn 9 Figure 2 2 I Bus Connections and Termination cccceeeeeeeeeeeeeeeeeeeeeeeeeeees 11 Figure 4 1 Location Of I Bus Termination Link 444444444nnnnnnnnn nennen 28 3 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com System Overview The BT 2 Burnt in Timecode unit extracts the Vertical Interval Timecode VITC or the Longitudinal Timecode LTC and displays this as ASCII Characters on the screen The main features of the BT 2 are as follows Reads Longitudinal and Vertical interval Timecode from an SDI Input Displays timecode on screen with a viewing option on the Flexipanel LCD displays LTC VITC Auto LTC and Auto VITC modes of operation Displays HH MM SS FF and user bits with field mark Re Inserts VITC driven by the LTC input LTC to V
23. ssue 2 or later cards Current Consumption lt 800mA at 5V Size 215mm by 100mm 4 2 Jumpering the I BUS CAN BUS Termination The I BUS Network is the control system under which all Products and Panels are networked together Under certain circumstances it is necessary to terminate the network This can be done on a Panel or a Product To terminate this product locate J6 on the BT 2 Processor Card supplied which is between U1 The large square chip and the Edge connector This is on the half of the card labelled CHP 100 Spartan2 Processor Jumper this with a 2mm link J6 19 0120 syvo02 12 gD a BEE 2 r g 3 a s 1 D PS aaa I ar Eke S a Figure 4 1 Location Of I Bus Termination Link 28 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com
Download Pdf Manuals
Related Search
Related Contents
AMP-amplifiers - user manual V1.0 Page 1 Page 2 ー ・ 道路走行・ ほ場の出入り ・ 車への横降しのときは Sony VGN-SZ680N/D Marketing Specifications Manual de Componentes y instalacion Landi ES Benutzerhandbuch für Polycom® HDX® Raum Tamron SP AF 28-75mm Di f2.8 (Canon AF) Alcatel-Lucent 500 DECT Handset Simmons Optics CV-4 User's Manual System 110/150 Manuale d`uso e manutenzione Manual para Caja Registradora modelo CR M Copyright © All rights reserved.