CHAPTER 1- SUMMARY OF USER`S COMMANDS

image

Contents

1. Function Procedure Quick arm ARM Arm by code ARM master code Stay Arm STAY Stay Arm by code STAY master code System disarm user code Bypass disarm duress code Free from siren user code Bypass un bypass zone 1 user code zone number Quick bypass un bypass zone zone Jat least 2 seconds Display trouble 1 3 Display time 1 4 Set change main code 1 5 master code 0 new code Set change a user code 5 master code 1 9 new code Set date 1 6 1 master code MM DD YY Set time 1 6 2 master code H H M M Auto arm time 6 3 master code H H M M Set follow me phone no 1 7 1 master code phone No 1 Set follow me phone no 2 7 2 master code phone No 2 Set follow me phone no 3 7 3 master code phone No 3 Set follow me phone no 4 7 4 master code phone No 4 On off buzzer 8 master code 1 On off door chime 8 master code 2 Audible kiss off 8 master code 3 Display memory 9 master code enevt number Test system 0 master code keypad panic alarm 1 2 at leadt 2 seconds keypad fire alarm 4 5 at least 2 seconds keypad special emergency 7 8 at least 2 seconds Escape ESC LCD Trouble Battery Low The Backup Battery Power is low AC Power AC Power is lost aroupie tere No Cloc
2. Hex date fast operation A STAY 1 B STAY 2 C STAY 3 D STAY 4 E STAY 5 F STAY 6 Locatio DER WA Report gt Description Num Digit Code 32 Zone 1 Alarm Reporting code 3 000 33 Zone 2 Alarm Reporting code 3 000 34 Zone 3 Alarm Reporting code 3 000 35 Zone 4 Alarm Reporting code 3 000 36 Zone 5 Alarm Reporting code 3 000 37 Zone 6 Alarm Reporting code 3 000 38 Zone 7 Alarm Reporting code 3 000 39 Zone 8 Alarm Reporting code 3 000 40 Keypad Fire Alarms Reporting code 3 000 41 Keypad Panic Reporting code 3 000 42 Keypad Special Emergency Reporting 3 000 code 43 Zone 1 Restore code 3 000 44 Zone 2 Restore code 3 000 45 Zone 3 Restore code 3 000 46 Zone 4 Restore code 3 000 47 Zone 5 Restore code 3 000 48 Zone 6 Restore code 3 000 49 Zone 7 Restore code 3 000 50 Zone 8 Restore code 3 000 51 Keypad Fire Restore code 3 000 52 Keypad Panic Restore Code 3 000 53 Keypad Special Emergency Restore 3 000 Code User 0 arm the Master Code a Quick Arm OR Keyswitch Arm 0 900 55 User 1 arm Reporting code 3 000 RP208CN User s and Installer s Manual Page 44 56 User 2 arm Reporting code 3 000 57 User 3 arm Reporting code 3 000 58 User 4 arm Reporting code 3 000 59 User 5 arm Reporting code 3 000 60 User 6 arm Reporting code 3 000 61 User 7 arm Reporting code 3 000 62 User 8 arm Reporti
3. UO is activated when any duress code is entered 14 AC Loss Follow Latched UO is activated due to a lack of power from the commercial AC UO is deactivated when the system is operating properly from commercial AC power 15 AC Loss Follow Pulse AC UO is activated for several seconds and then deactivates due to a lack of power from the commercial AC 16 Low Battery Follow Latched UO is activated due to low power from the backup battery UO1 is deactivated when the battery is in good condition 17 Low Battery Follow Pulse UO is activated for several seconds due to low power from the backup battery Zone 1 Alarm Follow Latched UO is immediately activated when an alarm occurs on Zone 1 RP208CN User 18 UO remains active latched for the duration of the alarm even after the system sounder times out UO is deactivated when Zone 1 goes into normal condition Zone 1 Alarm Follow Pulse 19 UO is immediately activated for several seconds pulse and then deactivates whenever Zone 1 goes into alarm 20 Zone 2 Alarm Follow Latched 21 Zone 2 Alarm Follow Pulse 22 Zone 3 Alarm Follow Latched 23 Zone 3 Alarm Follow Pulse 24 Zone 4 Alarm Follow Latched 25 Zone 4 Alarm Follow Pulse 26 Zone 5 Alarm Follow Latched 27 Zone 5 Alarm Follow Pulse 28 Zone 6 Alarm Follow Latched 29 Zone 6 Alarm Follow Pulse 30 Zone 7 Alarm Follow Latched 31
4. ROISCOK on the display which means all the zones are not triggered When Z1 Z2 Z3 Z4 Z5 Z6 Z7 or Z8 is are displayed on the display which means the zone is triggered Statue Explanation System Disarmed System Armed ROISCOK All the zones are secured and working normally Z1 Zone 1 was triggered An alarm has occurred on Zone1 Z2 Zone 2 was triggered An alarm has occurred on Zone2 Z8 Zone 8 was triggered An alarm has occurred on Zone8 3 ARM LED The ARM LED indicates whether or not the system is armed In armed condition the ARM LED is on in case of any violations there will be an alarm The ARM LED is flashing which means burglar fire or emergency alarm once has have occurred in the corresponding zone s The ARM LED is off when the system is disarmed Statue EXPLANATION When the system is armed in case of any emergency an alarm will occur The Siren will sound and system will also OG dial the follow me numbers and send alarm report to alarm center Off The system is disarmed Flashing Burglar fire and or has have once occurred RP208CN User s and Installer s Manual Page 5 4 READY LED The Ready LED indicates whether the system is working normally or not and also indicates whether system can be armed or not When disarm the LED will be on when arm the LED will be off STATUS EXPLANATION All the zones are working normally and then the syst
5. Un bypassing a Zone When an intrusion zone is bypassed the zone will not be armed when arming When disarming all the bypassed zones will be automatically un bypassed There are two methods of Bypassing Quick Bypassing It s defaulted that all the zones of RP208CN can be set as Quick Bypass Bypass a zone simply press the corresponding key for or above 2 seconds For example to bypass Zone 3 press digit 3 for 2 seconds then By Pass Z3 will be displayed on the LCD which means Zone 3 has been bypassed successfully Use the same way to un bypass the bypassed zone When Zone 3 is un bypassed Cancel BP Z3 will be displayed on the LCD Code Bypassing If RP208CN was programmed as code bypassing then press 1 Disarming Code Zone No to bypass the zone Use the same way to un bypass the zone 13 Escape Key ESC Keypad ESC is suitable for correction system operation 14 Emergency Keys RP208CN Keypad RP208KCL provides three emergency keys which can be RP208CN User s and Installer s Manual Page 12 pushed at anytime and the police fire department or medical assistance is required Emergency Alarm is defaulted as silence alarm Press 1 and 2 simultaneously and for at least two seconds will activate a Panic Alarm Press 4 and 5 simultaneously and for at least two seconds will activate a Fire Alarm Press 7 and 8 simultaneously and for at least two seconds will activate a Medical Emergency 15 E
6. s and Installer s Manual Page 23 8 Zone 3 Connector 18 Trouble Indicating Light 1 9 Zone 4 Connector 19 Trouble Indicating Light 2 10 Dial Switch 20 Touch Switch 21 Antenna Connector 1 6 9 are corresponding 1 4 receiver s channels should be connected 4 of the zones on RP208MB 2 The port 12v should connect to AUX on control panel the GND port to the COM 3 When using remote controller the port 3 should connect switch lock zone of RP208CN 4 In normal the dial 1 and 2 on the dial switch 10 should be set at the position ON Please refer to RP208EW4 User s Manual for more details RP208CN User s and Installer s Manual Page 24 vANOZ 3NOZ TINOZ LINOZ 398NOYL NWuYvIv HOLIMS Wai ATL AND EG sin nine w 9ZZ0 L007 zo c00 HOOSION 5 LoL TEL METAL TL DUL KTU DUL METAL a Fig 6 The Wireless Receiver Page 25 s Manual s and Installer RP208CN User CHAPTER 4 FUNCTION AND TECHNICAL DATA You can communicate your RP208CN 8 zones control pane through LCD Keypads RP208KCL Each RP208CN can match with 4 LCD keypads at most With the LCD Keypad s you can operate your system by arm disarm bypass emergency closing the siren inspecting trouble programming the system and so on The system status can be displayed by the LCD or and indicator light All of your system s detectors are wired to the control panel As such your s
7. 35 BLK the port should connect to the black line on the keypad 36 RED the port should connect to the red line on the keypad RP208CN User s and Installer s Manual Page 18 D09 2 AG We OS tre seeeis eee 04 E OS OQ Fig 2 RP208MB RP208CN User s and Installer s Manual Page 19 ov AT WHY Idi AZI WEY TV YIdNYL 1739 ON XNW LZ WO9 ZZ Z WO9 FZ SZ WO9 9Z Z WOO 8Z NYO 134 418 138 F nr Fig 3 Connection Instruction Page 20 s Manual s and Installer RP208CN User Install Control Panel and Keypad The RP208CN control panel should install in the aridity near by AC power supply which can t be power off and connect the ground well and be easy to connect the phone line Use correct tool avoiding the damage toward the equipments The keypad is generally installed in the open side of the entry the height should be easy to user The Tamper Button on the back cover of the keypad can prevent the keypad from being broken or tore down turn on it and press it tightly to the wall while installing Please connect the 4 lines of the keypad with the main board respectively according to the red black yellow and green sequence Such as Fig 3 shows Connect the Telephone Line There are two twin ports of telephone lines on the mainboard The ports which mark LINE used for input PHONE for telephone Such as Fig 3 shows Connect the Standby Battery
8. Please provide a standby battery DC12V inside to panel in case of the AC power is cut off Two lines marked BAT link the battery with anode red and the cathode black respectively Such as Fig 3 shows Don t conjunction any power before connected all the lines well Connect Transformer The output of transformer should be AC16 5V connecting into the AC two ports on the mainboard When AC power is different please carefully choose a right transformer to be applicable to AC220V or perhaps AC110V Remember The red lines for the high voltage do not mix with blue which is the low voltage Don t power the system before the installation finished well Connect Siren The port BELL is used for connect siren Please watch for cathode and anode when connecting RP208CN User s and Installer s Manual Page 21 Connect Detector s As the Fig 3 shows the wiring work must be done without power 1 Used and unused zone should connect with 2 2k Q termination resistors When connecting detector please install termination resistors in the detector to ensure the system of self protection function 2 The two ports of ALARM one for COM port and another for alarm zone ports respectively on the mainboard 3 TAMPER ports of detector connected to tamper zone and COM When there are many detectors TAMPER port in series to access tamper zone and COM port 4 DC12V in the detector connect AUX and COM respectively Do not mix anode
9. Quick Arming and Code Arming By pressing it the system will be fully armed 4 Key STAY is for Quick Stay Arming and Code Stay Arming By pressing it to arm only part of the zone is armed Each zone can be set as interior Zone or external zone When use STAY for arming the external zone is armed while leaves the interior zone disarmed 5 Under the disarmed status press to enter user s function mode Reference to CHAPTER 1 SUMMARY of USER S COMMANDS 1 Setting Changing and Deleting User s Code The default Master Code of RP208CN is 1 2 3 4 Unless your alarm company has already changed it to suit your preference it s best to modify this code to one which is unique and personalized RP208CN can set 10 of Codes one is Master Code and another 9 are User s Codes To change the Master Code and or to set up User Coeds follow the steps Make sure the system is disarmed when setting the code The User s Codes are only for Arming and Disarming the system Functions of the Master Code Adding changing and deleting User s Code Setting Time Clock Operating and testing Setting the follow me numbers RP208CN User s and Installer s Manual Page 7 Setting Changing the master Codes Step Operation 1 The system must be disarmed the ARMED LED will be OFF Enter the User Functions Mode 5 2 Enter the current 4 digit Master Code For example Press 1 2 1 3 4 3 Press 0 Enter
10. Zone 7 Alarm Follow Pulse 32 Zone 8 Alarm Follow Latched s and Installer s Manual Page 38 33 Zone 8 Alarm Follow Pulse Communication Parameters Locations26 29 Locations 26 and 27 allow you to define the manner in which the RP208CN communicates with the Central Station when it reports alarms Restores troubles openings closings and tests Digital Communicator Controls Locations 26 Default 41 First digit determines the number or hexadecimal digit corresponding to the Dialing Method Duty Cycle Redial Time desired amp Second digit determines the number corresponding to the Attempts Answering Machine Use UL Installation Attempts Attempts sets the Number of times the control panel will redial the Central Station after failing to establish a successful communication Voice Module If enabled YES voice messages will be sent If NO then tones will be used to represent an active alarm Location 26 Dialer Controls 1 Digit ee Redial Central 1Digit Dialing Method Duty Cycle Station 1 Pulse 20 pps 67 33 After 30 seconds 2 Pulse 10 pps 67 33 After 30 seconds 3 Pulse 10 pps 61 39 After 30 seconds 4 default DTMF N A After 30 seconds Location 26 Dialer Controls 2Digit 2Digit Attempts Voice Module 0 8 No 1 default 3 No 8 3 Yes 9 8 Yes Ceniral Station Protocols Location 27 Default 00 To understand and modify the Code f
11. address the needs of many homes offices and small businesses Its operation is designed around microprocessor and EEPROM Electrically Erasable Programmable Read Only Memory technology which stores without the need for a source of power the system s operating program and its programmable parameters System programming may be performed from one or more LCD keypad s designed specifically for that Before Installation You shall read the all the subjects in manual deeply before installation to avoid unnecessary damage to the products Please use the tool correctly you should install the system first then power the systems Please make sure the systems are not powered when you handle the connection Otherwise this can make the system self protection the components burning or other problems The 2 2kQ resistors which dispensed with the systems should connect with the nearest location of the detector FAQ of Installation and Solution The RP208CN has self protection system and self check function The Keypad will make a sound to prompt the user to check up and Correction when RP208CN User s and Installer s Manual Page 16 systems are installed or set in error 1 Please check if the tamper button on the back of the keypad installed in the correct and under working conditions when keypad emit the continuous beep after system installation is complete and be powered 2 Please review the chapter 2 No 17 Trouble Display
12. and cathode 5 Please connect the port of UO when need Connect Voice Module As Fig 4 connecting voice module just need to insert it into the connector on the control panel 1 record recording button 2 play test record button 3 the eligible label including production serial number tester number production type and version number 4 recording microphone RP208CN User s and Installer s Manual Page 22 Fig 4 Voice Module Connect Remote Receiver When arm or disarm by a remote controller please programming a zone as swi tch lock zone And connect the remote receiver as following O O COIWGIGIGIG O enolvec 82 e2 k2 82 61 Kt p GND connect to the COM power negode of the mainboard VCC connect to the AUX power anode of the mainboard B2 connect to the port of Key switch Zone G2 connect to the common earth K2 set aside B2 set aside GI set aside K1 set aside Fig 5 Remote Receiver Connect Wireless Module The function and the port of RP208EW4 expansion wireless module 1 12VDC Power 11 Zone 1 Indicating Light 2 Set Aside 12 Zone 2 Indicating Light 3 Remote Armed 13 Zone 3 Indicating Light 4 Set Aside 14 Zone 4 Indicating Light 5 Trouble Output 15 Receive Data Indicating Light 6 Zone 1 Connector 16 Interfered 7 Zone 2 Connector 17 Setting Indicating Light RP208CN User
13. bavedsades eiiasiantecen ans 14 19 Get Events from Event LOQQEN ssccccsceeceseeeeseeeseseseesesesentees 14 20 On Off Door CRIME Ua 15 CHAPTER 3 INSTALLATION s ssesesesseseseoseosesenseseneososesensoseneosesese 16 BEFORE INSTAULATION AA AA AAA AA AAA 16 FAQ OF INSTALLATION AND SOLUTION wwssanewnanamwanawunanuwananzwananzmanzaninanazanaznza 16 THE MAIN B0AR0 AA AAA KAWA AAA KANA AAA 17 RP208CN User s and Installer s Manual Page 1 INSTALL CONTROL PANEL AND KEYPAD 00ssececececeeseseececeeeseaueeeseeeeeeseaneneeeess 21 CONNEC RIE WELEPHONE WEINE 0 cccccececeececcececeeeceeeeaeeeceeeseeneeaeeeeeeeeeees 21 CONNECT THE STANDBY BATTERY 222 0 ccceeeeeeeeeeeaeceeeeeseceeeaeeeeeeesesenceeaeeeeeeetees 21 CONNECT TIRANSFORU E gt oe i ee ini iii 21 CONNECT EEN EE SEE 21 CONNECT DETE OSTORIUS 22 CONNECT VOICE MODULE orrrononnnnvrvvrnnnrnn nav nvnnnnnnr nar nvnnnnannnnnarnennnnnnenannnne 22 CONNECT WIRELESS MODULE cccccceecsecsncececeeeeeeseeeeeeceeeseeneeaeeeeeeeetees 23 PLEASE REFER TO RP208EW4 USER S MANUAL FOR MORE DETAIL S ii 24 CHAPTER 4 FUNCTION AND TECHNICAL DATA sseeeeeeeeee 26 MAIN FEATURES OF FIRZA C EEE 26 MAIN FEATURES OF RP208MB cceseeececeeeeeeeeeeeeeeeseaeeeseeaeeeseeeeeeeenateeeseaas 27 RESTORING FACTORY DEFAUT E 30 PROGRAM ELA EEEE 30 CR EO LOCATION DYA i sss see se ss seers 30 ENTIRE
14. press 1 To delete the User Code1 press 2 3 To delete the User Code1 press 3 The other Codes can be deleted in the same way 4 Enter the 5 If successful the keypad will emit a one second confirming tone The selected User Code is now deleted 2 Setting Date and Time Set date 6 1 MASTER CODE MM DD YY Month Date and Year should all be two digits Set time 6 2 MASTER CODE HH MM Use a 24 Hour format Hour and Minute should be two digits For example if you want to enter 16 28 August 18 2006 operate as 6 1 MASTER CODE 08 18 06 6 2 MASTER CODE 16 28 3 Displaying System Date and Time Press 4 to check the system time on LCD keypad And the format should be MM DD YY Hour Minute 4 Setting Follow me Number In case of an alarm event a phone call can be made to one or more predefined phone number There are three different tone types that represent burglary fire and special emergency alarms The Follow Me function can support four phone numbers for each system Make sure the numbers are all correct then enter Operate as Set Follow Me Phone NO 1 7 1 MASTER CODE Phone NO 1 Set Follow Me Phone NO 2 7 2 MASTER CODE Phone NO 2 Set Follow Me Phone NO 3 7 2 MASTER CODE Phone NO 3 Set Follow Me Phone NO 4 7 2 IMASTER CODE Phone NO 4 RP208CN User s and Instal
15. sec 650ms 1900Hz F 10 pulses sec 650ms 1900Hz PPS Kiss off ainn Inter Digit Code Format Name her Handshake V lidation Time Format Silent Dual Knight ADEMCO 10 1400Hz 650 OF round Slow Silent Dual Knight ADEMCO 10 1400Hz round 650 4F Slow Extended RP208CN User s and Installer s Manual Page 40 Radionics Dual DCI Franklin Slow 10 2300Hz round 650 if Silent Knight Fast 20 1400Hz Dual 650 OE round Silent Knight Fast Dual NG 20 1400Hz yee 650 4E Sescoa Franklin Dual Vertix DCI 20 2300Hz 650 56 round Extended Universal high speed 20 2300Hz Dual 390 12 gn Sp round Radionics 20 1400Hz Dual 390 02 round Radionics 20 2300Hz Dual 390 12 round Radionics Extended 20 1400Hz Dual 390 42 round Radionics Extended 20 2300Hz Dual 390 52 round Radionics 40 1400Hz Dual 390 00 round Radionics 40 2300Hz Dual 390 10 round Radionics Extended 40 1400Hz Dual 390 40 round Radionics Extended 40 2300Hz Dual 390 50 round Radionics 40 1400Hz Parity 390 20 Radionics 40 2300Hz Parity 390 30 Radionics Extended 40 1400Hz Parity 390 60 Radionics Extended 40 2300Hz Parity 390 70 CS Protocols Location 28 default 03 When selecting 01 the contact ID format all the reporting codes will be automatically applied to the locations of the reporting codes When selecting 03 the Pulsed Protocol the default for all the reported codes will be 00 and a
16. switching an external device on or off Once the Utility Output is activated the device will be connected between AUX 12V and ground OV This connection is capable of switching light loads of no more than 70mA When input different data in locate 22 UO will active in different way Digit Event and Result 00 Not Active default UO offers no response to any system activity UO 01 preparation Arm Follow Latch UO is activated when the system is armed The activation occurs 02 after the expiration of the exit delay period The UO remains active latched while the system is armed When disarming the system the UO deactivates Unlatches Arm Follow Pulse UO is activated when the system is armed The activation occurs after the expiration of the exit delay period The UO is activated for several seconds pulse after which is deactivated 03 Alarm Follow Latched UO is immediately activated when the system goes into any type of alarm i e intrusion fire keypad initiated panic UO remains active latched for the duration of the alarm even after the system s sounder times out UO is deactivated when the system is disarmed 04 Alarm Follow Pulse UO is immediately activated of several seconds and then deactivated whenever the system goes into any type of alarm i e intrusion fire keypad initiated panic 05 Panic Follow Latched UO is activated immediately when a PANIC alarm is trigg
17. the area code When done with your complete input press to store it Up to 20 digits can be entered to the location To delete an existing phone number just press the Key To delete an existing phone number simple press the key to enter or replace the phone number required to reach the primary Central Station include all access digits e g 0 to 9 and the area code When done with your complete entry press to store it Up to 20 digits can be entered to the phone number For your records enter the complete phone number above If required include the following special functions to achieve the effect listed in the table Location 03 the Second Central Station phone number Same as in Location 02 Location 04 Preparation Location 05 User s No Default 0000 PURPOSE to assign the system s Central Station Account Number Hexadecimal account numbers those using 0 through 9 and A through F are accepted by RP208CN Use the key combinations below to enter hexadecimal digits A through F Hex digit Press Hex digit Press Acct No RP208CN User s and Installer s Manual Page 32 A STAY 1 D STAY 4 B STAY 2 E STAY 5 C STAY 3 F STAY 6 0 will not send a digit to the central station to send 0 use A digit Location 06 Preparation Location 07 Preparation Installer C
18. when keypad notified a rhythmic beep beep beep In that case may including the following situation battery power shortages AC power off no set clock time and date the phone lines for communications or the line for alarm has a fault 3 Keypad will emit three sound beep beep beep when input the wrong operation 4 Please check whether the connect between the port ALARM on the detector and control panel is connected firm and connected the 2 2k ohm resistor correctly when the Siren alarmed under armed state 5 Please check whether the shell of detectors is installed correctly the tamper switch of detector is ready The connect between the port TAMPER on detector and control panel is connected firm and connected the 2 2k ohm resistor correctly when the Siren alarmed under disarmed state 6 Under disarmed state when the keypad display Z1 NOT READY it means the zone 1 is not ready The Main Board As Figure 2 the function of connection port as following 1 the port LINE for telephone line 2 the port PHONE for telephone set 3 Dialing LED Indicator 4 the jumper DEFAULT for restore factory defaults 5 the connector for the voice module 6 the type and version number 7 eligible label and production serial number 8 AUX safety for assistant power 0 5A 9 BELL safety for siren power 1A 10 BAT safety for standby power 2A 11 BAT the cathode of
19. 7 Zone 4 Settings 18 Zone 5 Settings 19 Zone 6 Settings 20 Zone 7 Settings 21 Zone 8 Settings 22 Utility Output 23 24 25 26 Dialer Controls 27 CS Protocols 1 28 CS Protocols 2 29 30 System Controls 31 Periodic Time Set 32 Zone 1 Alarm 33 Zone 2 Alarm 34 Zone 3 Alarm 35 Zone 4 Alarm RP208CN User s and Installer s Manual Page 49 RP208CN User 36 Zone 5 Alarm 37 Zone 6 Alarm 38 Zone 7 Alarm 39 Zone 8 Alarm 40 Kpd Panic Alarm 41 Kpd Fire Alarm 42 Kpd SP Alarm 43 Restore Code Zone 1 44 Restore Code Zone 2 45 Restore Code Zone 3 46 Restore Code Zone 4 47 Restore Code Zone 5 48 Restore Code Zone 6 49 Restore Code Zone 7 50 Restore Code Zone 8 51 Restore Kpd Fire 52 Restore Kpd Panic 53 Restore Kpd SP 54 User 0 Arm 55 User 1 Arm 56 User 2 Arm 57 User 3 Arm 58 User 4 Arm 59 User 5 Arm 60 User 6 Arm 61 User 7 Arm 62 User 8 Arm 63 User 9 Arm 64 User 0 disarm 65 User 1 disarm 66 User 2 disarm 67 User 3 disarm 68 User 4 disarm 69 User 5 disarm 70 User 6 disarm 71 User 7 disarm 72 User 8 disarm 73 User 9 disarm 74 Auto ARM 75 Forced arm 76 Stay Arm 77 Duress Disarm 78 Daily test Report 79 Rpt Code Low Bat 80 Rpt Code AC Loss 81 Rpt Code Fire Tb 82 Rpt Code Bell Loop s and Installer s Manual Pag
20. Delay Default 030 Location 12 is used to set the time of enter delay between 001 and 255 For example 030 means the delay time is 30 seconds When enter into the locale it won t alarm to disarm in the time of enter delay Location 13 Bell cutoff Time Default 03 Location 13 is used to set auto alarm time of the External Sounder before it shuts down automatically Enter the number of minutes between 01 and 90 Intrusion Zone Types and Zone Sounds Locations 14 21 Locations 14 through 21 are identical and are corresponding to Zone 1 through 8 respectively Each of these locations contains two digits The first digit is used to set the type of the zone the second digit is used to set the type of the sound Attention Each zone must be connected to an EOL 2 2KO resistance when installing even if the zone not in used 1 Digit Zone Type and comment of Zone 1 8 Not Used 0 All unused zones should be given this designation It is also used to disable a zone Enter Exit Delay 1 If violated a zone with this designation will not cause an intrusion alarm during the Entry and Exit Delay periods Instant Intrusion 2 Causes an immediate intrusion alarm if violated when the system is in arm state Entry Follower A zone s given this designation will cause an immediate intrusion 3 alarm when violated unless an Entry Exit zone was violated first if so an Entry Follower zone s will remai
21. INDEX CHAPTER 1 SUMMARY OF USER S COMMANDS ss seseseesesese 3 CHAPTER 2 ABOUT THE KEYPAD sssevevevevsensveesenevevsensveesenenssnessveessn nse 4 AIPAC LCD KEVEAD ere 4 ED INDICATION AND KS se 5 FUNCTION AND OPERATION i itis sets sss ses 7 1 Setting Changing and Deleting User s COde lt lt 7 2 Setting Date and TIMe w w wwswwmmmmmmmmemmm mmama 9 3 Displaying System Date and Time onrnnnrnnrnronenrrnnrrnrnrrnrnrrnnnrnrnernnn 9 4 Setting Follow me Number rnrnnnnnnrnrnenrnnnrrnrnrnrnrnnnnnrnvsnrnrrensrsrnesenn 9 5 Quek A e a E a a a E RE Ai 10 6 Coda ANTHAG WA e ensa e ae ENES 10 7 Bell Squawk on Arming sesseseeseeseseseeseceseeeseeenseceseeeeseseaeeeeseeeeeeees 10 8 DISarming BI Ba ieii 10 9 On Off Audible kisS OFf wwwwwwmwmmmmmmmmmmmimimimimi 11 10 Duress Disarming smrrrnrnrvnrnrrnvnvvnvnvnnnnrnvnrnrnrnnnsrsrnrrnrnenessrsrneseenenenn 11 11 Cutting off Sounder and Stop Auto dialing 11 12 Bypassing Un bypassing a ZONE wswwwwwwwmwwww 12 13 Escape Key JESCJ wswsssemmmmemammammnenimmammmwi mm 12 14 Emergeney KOYS ai wanawa aaa aa 12 15 Entry and Bidii iii 13 16 24 Hour Zone aroaro A E R R 13 17 Trouble DiSPIAY ccceccccsceseeseeseseseseseseeeeseeensceseseesceeseeseaeeesesentees 13 18 Zon FB avse ks ieee scda todas
22. PROSA eee eee ree 31 A PROGRAMMING TUTORIAL 0 ccceeeeeceeeenneeeeeeeeeeeeeeeeeesaeeeseeeaeeeenneeeeseneeeeseaas 31 General System Parameters Locations 00 07 32 Installer Code Location O8 10 eeceececcccsceseseseesesesetseseseeseeeseseaeaees 33 SYSTEM TIME LOCATIONS 14 15 i ii ts see KE AKAA SUA KAKA 33 INTRUSION ZONE TYPES AND ZONE SOUNDS LOCATIONS 14 21 s zsamaaaa 34 UTILITY OUTPUTS EVENT AND RESULT LOCATIONS22 DEFAULTOO 36 COMMUNICATION PARAMETERS LOCATIONS26 29 wwsamwanaamwaamamunamwnanaza 39 DIGITAL COMMUNICATOR CONTROLS LOCATIONS 26 DEFAULT 41 39 CENTRAL STATION PROTOCOLS LOCATION 27 DEFAULT OO wawa 39 CS PROTOCOLS LOCATION 28 DEFAULT O3 wawwwanaamamwnwanaawamamwanaawawa 41 RE ODICMMECT Ile Loose 31 43 COMMUNICATOR REPORTING CODES LOCATIONS 32 94 linee 43 REPORTING CODES FOR ALARM EVENTS sesesesesesesesesesemeeee 43 RP208CN CONTROL PANEL CONTACT ID REPORTING CODES 47 RP208CN User s and Installer s Manual Page 2 CHAPTER 1 SUMMARY of USER S COMMANDS The Summary of User s Commands offers installers and users a quick and convenient way to operate control panel All can be done under the state of disarm and so it doesn t need to enter programming statue For detailed information please go chapter 2
23. Zone Remote Zone etc Entry Exit Delay Zone A delay period was chosen during your system s installation to provide suitable time to allow for your entry and exit Exit Delay is the max time from pressing the ARM key to exit the zone Entry Delay is the max time from entering the zone to DISARM If the time exceeds the max time and the detector is triggered again then the system will alarm at once Instant Intrusion Zone When it is triggered the system will alarm instantly Panic Zone Used for panic button which is 24 Hours Zone Fire Zone Used for smoke detector and gas detector which is 24 Hours Zone Tamper Zone Used for connecting with the tamper connector of detector which is 24 Hours Zone Remote Zone Used for connecting with remote receiver which is 24 Hours Zone For user s convenience all RP208CN zones have been defaulted as following Zone 1 Entry Exit Delay Zone Zone 2 Instant Intrusion Zone Zone 3 Instant Intrusion Zone Zone 4 Panic Zone Zone 5 Fire Zone Zone 6 Tamper Zone Zone 7 Interior Zone Zone 8 Interior Zone 19 Get Events from Event Logger You can retrieve events located in the event Logger memory from LCD keypad up To 50 events including arm disarm alarm etc Events are presented from the Last entered to the first Registered The affairs serial number use for 2 data 01 50 Press 9 MASTER CODE EVENT No The keypad display format MM DD HH MM 2 affairs cod
24. ary Power 0 5A Fuse BELL Bell LS Power 1A Fuse BAT Battery Power 2A Dimension weight 80 167mm 0 17kg Keypads LCD Keypad Current consumption 90mA typical 130mA max Control panel connections 4 wire up to 1000M from panel Dimensions 110 130 25mm Weight 0 23kg RP208CN User s and Installer s Manual Page 29 CHAPTER 5 PROGRAMMING DIRECTION Restoring Factory Defaults Recover the default of the control panel before program 1 Connect the keypad and the control panel 2 Check if the line have linked correctly on all the other port 3 Turn off all the power 4 Short circuit the default of the main board of the control panel reference the pic2 in page 19 5 Reconnect the power AC or the standby battery 6 When you hear a brief sound beep cut J1 At this moment the default has been recovered already 7 Please check the signal light when you in program mode the light of READY is flicker at this time you can program Program Explain First confirm the Default jumper is off Keep in disconnection when programming Programming is a process of altering or setting the location data of the control panel RP208CN has 94 locations 01 94 for setting data and each data will correspond to a different function of the control panel The location are made up of 2 digital the data of location are made up of 1 digital 2 digital or many digital RP208CN has the adva
25. aster this operation subsequent programming should be easy Operation Action Comments Enter the Programming Enter the factory A long beep will sound 1 Mode default Installer confirming successful entry Code into Installer Programming 0206 LCD display ADD Access the Installer Press 0 8 ARM No confirming beep 2 Code stored in Location 08 Enter a unique Installer Enter 5 6 7 8 No confirming beep 3 Code for this tutorial we ll use 5 6 7 8 Store the data you Press Along beep will sound lhave entered confirming that data has 4 been properly stored if a wrong number of digits entered three error beep will sound after pressing Check the data stored The data display 5678 5 lin Location 08 on the LCD RP208CN User s and Installer s Manual Page 31 Go to another location Press the desired Press ARM along to go to 6 Iof your choice two digit location the next sequential location and ARM Exit programming Enter your Installer Along beep will confirm your 7 Code and press actions ARM Data In the Location General System Parameters Locations 00 07 Location 01 Preparation Default 00 Location 02 the First Central Station phone number Explain To input or alter the phone number is required to enter the location and input all digits include
26. ation 1 External sounder continuous default Cause the external sounding device to annunciate steadily without breaks in the sound cadence the sound will continue until the sounder times out or the system is disarmed External sounder pulses 2 Cause the external sounding device to produce a pulsed of staggered annunciation this sound is usually recommended for fire alarm annunciation Keypad sounder Only 3 Cause the piezo sounder within the system s keypad s only to beep rapidly External sounder Keypad Sounder 4 Causes the external sounding device to annunciate continuously without breaks in the sound cadence causes the piezo sounder within the system s keypad s to beep rapidly External Sounder When Armed keypad Sounder When Disarmed 5 Related to 24H Zones When alarm during disarm the keypad s buzzer will be activated When alarm during armed system the external sounder will be activated RP208CN User s and Installer s Manual Page 35 Door Chime Assigned to an opening which when violated during the disarmed will cause the system s keypad s to beep once during an alarm the external sounding device will annunciate continuously without interruption When alarm occurs during armed system only the external sounder will be activated For example if the zone 1need to set to be entry exit delay zone and need the exterior alarm intermittent sound at the same time keypad buzzer sound wh
27. d and the Exit Delay expires 3 Minute Bypass Enabled If selected 3 Minute Bypass Enabled bypasses all zones automatically for 3 minutes when power is restored to an un powered system to prevent potential false alarms by allowing time for the stabilization of motion and or smoke detectors First digit determine the number or letter corresponding to the choices involving Quick Arm Quick Bypass Loudspeaker Bell Siren 0 Second digit determine the number or letter corresponding to the use of silent Panic Bell Squawk on Arming 3 Minute Bypass Location 30 System Controls 1 Digig 1 Digig Loudspeaker Bell Siren uae Quick Bypass 0 Bell Siren NO YES 1 default Bell Siren YES YES RP208CN User s and Installer s Manual Page 42 4 Bell Siren NO YES 5 Bell Siren YES YES 8 Loudspeaker YES NO Location 30 System Controls 2 Digit 2 Digit 3 Minute Bypass Pa Bell Squawk On Arm 0 Enabled NO NO 1 Enabled YES NO 2 Enabled NO YES 3 default Enabled YES YES 4 Disabled NO NO Periodic Test Time Location 31 If desired the RP208CN can send a daily test transmission to the Central Station to Verify the operation of the Unit s Digital Communicator Location 31 Periodic Test Time Default 0000 Sets a fixed daily time for sending an test transmission to the Central Station The chosen time is expressed in 24 Hour format follow
28. e Zone No or User No RP208CN User s and Installer s Manual Page 14 The affairs type is as follows 11 Zone Alarmed 10 Zone Restore 21 Keypad Panic Alarm 22 Keypad Fire Alarm 23 Keypad Medical Emergency 51 User Arm 50 User Disarm 53 Auto Arm Zone No or User No When the event is alarm or restoration the last digit of the event shows the Zone No When the event is disarm or arm the last digit of the event shows the User No 20 On Off Door Chime Assigned to an opening which when violated during the disarmed will cause the system s keypad s to beep once during an alarm the external sounding device will annunciate continuously without interruption When alarm occurs during armed system only the external sounder will be activated Enter 8 Master Code 2 to turn on off the door chime RP208CN User s and Installer s Manual Page 15 CHAPTER 3 INSTALLATION The Series of Control Panel Which is Designed and Produced by ROISCOK Integrate Perfect Function and Advanced Technology ROISCOK s Control Panels Use the Separated Control Keypads and Has Strong Ability to Prevent Destroy All Zones Are Programmable Have Built in Digital Communicator Flexible Connecting to Alarm Centre Compatible to All Popular Communication Format Attached Duress Code Consecutive Output With Easier Programming and More Elegant Shape Everywhere Shows the Products Luxury The RP208CN are intended to
29. e 50 83 Restore Code Low Bat 84 Restore Code AC Loss 85 Restore Code Fire Tbl 86 Restore Code Bell Loop 87 Zone 1 Bypass Restore 88 Zone 2 Bypass Restore 89 Zone 3 Bypass Restore 90 Zone 4 Bypass Restore 91 Zone 5 Bypass Restore 92 Zone 6 Bypass Restore 93 Zone 7 Bypass Restore 94 Zone 8 Bypass Restore Phone Phone2 RP208CN User s and Installer s Manual Page 51
30. em can be armed now Off 1 Someone is moving in the zone 2 The system is armed Flashing The system is under the programming status On 5 BYPASS LED The BYPASS LED Indicate that one or more of the system s intrusion zones have been bypassed for more information on bypassing 6 FIRE LED When fired the LED flashing rapidly 7 TAMPER LED When the detector s or the keypad is are tampered or destroyed a Tamper Code report will be sent and the LED will be flashing 8 System Arming ARM When ARM key is depressed all the zones are armed 9 Stay Home Arming STAY Home Arming or Stay Arming allows individuals to remain inside and move about the premises even after the system is armed Home Arming arms the perimeter detectors e g door and windows while leaving interior detectors e g motion detectors disarmed bypassed When STAY key is depressed the interior zones will not be armed 10 Exit Delete ESC Key ESC is suitable for correction system operation RP208CN User s and Installer s Manual Page 6 11 Digit Keys When programming key in 0 9 digits 12 Function Key When programming key to enter function mode and for confirmation Function and Operation Keys and Functions The Keys can support the following functions 1 Enter digit s for Arming Disarming Panic Alarm Programming etc 2 Enter user s function mode 3 Key ARM is for
31. en need to alarm then input 14 in location 14 If the 3 zone need to set to be active zone and need the exterior alarm intermittent alarm then input 32 in locate 16 The zone characteristic of default Zone 1 Entry Exit Delay Zone zone type is 11 Zone 2 Instant Intrusion Zone zone type is 21 Zone 3 Instant Intrusion Zone zone type is 21 Zone 4 Panic Zone zone type is 70 Zone 5 Fire Zone zone type is 52 Zone 6 Tamper Zone zone type is 61 Zone 7 Interior Zone zone type is 41 Zone 8 Interior Zone zone type is 41 Special Zones Suggestion a Zone 5 is reserved as a Fire Zone Supports Smoke Detectors and or Gas Detectors A fire zone cannot be disabled or bypassed For fire zone the recommended default zone sound is External sounder pulsed However it is possible to change the zone sound and type to any of the ones provided in the previous list Urgency zone alarm doesn t result the siren sound but calling to the CMS or follow me numbers Zone 6 on the RP208CN is reserved as a Tamper Zone This zone can be programmed to any zone type If the zone was programmed as Tamper in violation a Tamper Code report will be sent and the Tamper LED on the keypad will light up Utility Outputs Event and Result Locations22 Default 00 The RP208CN supports one open collector Utility Output derived between the RP208CN User s and Installer s Manual Page 36 UO ECL and AUX terminals which can be used for
32. ered by 06 a violation of a zone defined as Panic or by pressing the keypad s 1 and 2 keys simultaneously for two seconds UO is deactivated when the system is disarmed Panic Follow Pulse UO is activated for several seconds when a PANIC alarm is 07 triggered by a violation of a zone defined as Panic or by pressing the keypad s 1 and 2 keys simultaneously for two seconds Fire Keying Follow Latched UO is activated immediately when a Fire alarm is triggered by a 08 violation of zone 5 defined as Fire or by pressing the keypad s 4 and 5 keys simultaneously for two seconds UO is deactivated when the system is disarmed Fire Keying Follow Pulse 09 UO is activated when a Fire alarm is triggered by violation of zone 5 defined as Fire Or by pressing the keypad s 4 and 5 RP208CN User s and Installer s Manual Page 37 keypad s simultaneously for two seconds 10 Special Emergency Keying Follow Latched UO is activated immediately when pressing the keypad s 7 and 8 keys simultaneously for two seconds UO is deactivated when the system is disarmed 11 Special Emergency Keying Follow Pulsed UO is activated for several seconds when pressing the keypad s 7 and 8 keys simultaneously for two seconds 12 Duress Code Follow Pulse UO is activated for several seconds and then deactivates when any duress code is entered 13 Duress Code Follow Latched
33. g If selected Bell Squawk on Arming will produce a brief confirmation chirp from the system s external sounder s once the system is armed and the Exit Delay expires To cancel it refers to Location 30 in Chapter 5 8 Disarming RP208CN can set 10 Codes 4 digits one Master Code and 9 User Codes In arming status simply enter any code of the 10 codes to disarm RP208CN User s and Installer s Manual Page 10 Step Operation When enter the arming zone the keypad will beep one time 1 which means the system is in entry delay status The entry delay time is defaulted as 30 seconds Disarming an armed system Before the Entry Delay expires enter the four digits of your User Code Or it will alarm 2 NOTE If you make a mistake when entering your User Code the keypad will produce three short beeps and the LCD keypad will display error If so press ECS and re enter the above sequence correctly 9 On Off Audible kiss off When disarm the system LCD keypad will send out a long Beep at the end of the Delay time Press 8 User s Code 3 to on off the buzzer 10 Duress Disarming If you are ever coerced to disarm your system you can comply with the intruder s wishes while sending a silent duress alarm to the Central Station To do so you must use a special Duress Code Which when used will disarm the system in the regular manner while simultaneously transmitting a silent alarm t
34. ing examples 8 30 AM 0830 11 15AM 1115 4 30 PM 1630 If desired disable the test transmission capability by accepting or entering the default 0000 Note Failure to set the systems time clock will prevent the code from being sent to the Central Station Communicator Reporting Codes Locations 32 94 The reporting codes is a report when the system has something happened to give a report to the alarm center Different status will send different report Reporting Codes for Alarm Events To program the codes that will be transmitted by the RP208CN to the Central Station To prevent the corresponding event from being reported use a double zero 00 the default in the location Notes on Alarm Restores An RP208CN Restore Repot informs the Central Station that the external sounder s operation initially triggered by the respective alarm condition has RP208CN User s and Installer s Manual Page 43 either timed out or been silenced by the act of system disarming Be sure to check with Central Station personnel if restore are permitted and if so what codes are required Annotate When the communicate protocol is CID separated codes is the same as restore codes ABC input the last 3 digit OABC When the communicate protocol is4 2 the first 2 digit are separated reporting codes AB the last 2 digit are restore reporting codes CD total are 4 digit ABCD
35. k Clock have not been set No Communication The Communication is in trouble No Siren The Siren connection is in trouble RP208CN User s and Installer s Manual Page 3 CHAPTER 2 ABOUT THE KEYPAD RP208KCL LCD Keypad The RP208CN can support LCD Keypad Each control panel can work with four LCD Keypads at most Each keypad in your system reports its status by its LED lighted indicators and LCD display Through its keys you can enter commands to Arm and Disarm the system bypass intrusion zones report emergencies stop the siren checking the trouble programming the system and other handling 1 2 3 PROWER 4 5 6 ROISOK 7 8 10 12 11 Fig 1 Layout of the RP208KCL Keypad Instruction 1 Power 7 Tamper 2 LCD Display 8 Arm key press 3 Arm 9 Stay key press 4 Disarm 10 Buzzer 5 Bypass 11 Exit Delete key press 6 Fire 12 Digit and Function key press RP208CN User s and Installer s Manual Page 4 LED Indication and Keys 1 Power LED On The system is operating properly from commercial AC power its backup battery is in good condition Off The system is inoperative due to the lack of power from both commercial AC and backup battery 0 Flash Indicates a trouble condition 2 LCD Display The LCD Display on RP208KCL indicate the status of each of the system including zones Triggered Armed Disarmed system Trouble Time and other programming information If there is only
36. ler s Manual Page 9 5 Quick Arming RP208CN can be divided as interior zone and external zone by programming Zone 7 and Zone 8 are defaulted as interior zone Press ARM and all the zones will be armed Press STAY then external zone will all be armed while leaves the interior zones disarmed Step Operation Before you arm your system all of its zones must either be secured or bypassed The keypad s READY LED if lit indicates that all zones are secured If the READY LED is not lit one or more unsecured zone s will be display on the LCD Quick Arming and Code Arming 2 Quick Armed Armed the system just by press ARM amp Quick Stay Armed Stay Armed just press STAY Three short Beep from the keypad when there are some errors 3 x E in entering Then re operate it When arming the system there will be one confirmation sound 4 which means the exit delay begin now Then leave here before the exit delay time is over to avoid false alarm The exit delay time is defaulted as 30 seconds 6 Code Arming Your RP208CN offers two methods of arming Quick Arming and Code Arming It s defaulted as quick arm If the user requires code arm it should be set when programming in advance When RP208CN is set as code arm it can not support ARM and STAY for quick arming And it should be operated as ARM Master Code or STAY Master Code to arm or stay arm 7 Bell Squawk on Armin
37. n bypassed until the end of the Entry Delay period Interior Entry Delay Follower 4 If the system is armed to AWAY ARM mode this type of zone behaves like the Entry Follower described above If the system is armed to the STAY mode this type of zone will be bypassed RP208CN User s and Installer s Manual Page 34 Fire Zone Intended for smoke or other types of fire detectors If violation will cause an immediate fire alarm regardless of the system s 5 armed disarmed state Suggest Zone 5 can be programmed as a fire zone A fault in the wiring of any fire zone if supervised will cause a fire alarm manifested by a rapid flushing of the keypad s Fire LED Tamper Zone 6 If violation will cause an immediate tamper alarm regardless of the system s armed disarmed state Suggest Zone 6 on RP208CN to be a Tamper Zone Panic Zone 7 If violated an immediate panic alarm will be announced regardless of the system s armed disarmed state Key switch Zone Instant If desired for system arming and disarming an external SPST 8 spring loaded normally open momentary type key switch can be added The key switch permits an instant disarming of the system after tripping And when arming the system an exit delay will follow 2 Digit Zone sound and comments of Zone 1 8 Silent 0 A violation during the armed period will produce no sound The resulting alarm can still be reported to the Central St
38. ng code 3 000 63 User 9 arm Reporting code 3 000 User 0 disarm Reporting code 64 Key switch disarm 8 000 65 User 1 disarm Reporting code 3 000 66 User 2 disarm Reporting code 3 000 67 User 3 disarm Reporting code 3 000 68 User 4 disarm Reporting code 3 000 69 User 5 disarm Reporting code 3 000 70 User 6 disarm Reporting code 3 000 71 User 7 disarm Reporting code 3 000 72 User 8 disarm Reporting code 3 000 73 User 9 disarm Reporting code 3 000 74 Auto ARM report code 3 000 Forced arm when the system is 75 armed with a bypassed zone 3 000 Reporting code Stay arm when the system is armed 76 to the Stay At Home mode 3 000 Reporting code 77 Duress Disarm 3 000 78 Daily test Report Code sent everyday 3 000 at the time specified in Location 24 79 Low Battery Reporting code 3 000 80 Loss of AC Power for at least 15 min 3 000 Reporting code 81 Fire zone trouble Reporting code 3 000 82 Bell Loop Interrupted Reporting code 3 000 83 Low Battery restore Reporting code 3 000 84 Loss of AC Power restore Reporting 3 000 code 85 Fire zone trouble restore Reporting 3 000 code 86 Bell Loop Restored Reporting Code 000 87 Zone 1 Bypass Restore Reporting 4 ABCD code 88 Zone 2 Bypass Restore Reporting 4 ABCD code 89 Zone 3 Bypass Restore Reporting 4 ABCD code 90 sa 4 Bypass Restore Reporting 4 ABCD RP208CN User s and Installer s Manual Page 45 91 Zone 5 By
39. ntage of agility and compact in programming user only have to alter or set part or all the data of location Not all location need to be set and most of the location can only use the default data Connect the mainboard and the control panel use the RP208KCL keypad to program when the power is on Check Location Data Check location data need in the state of program mode LCD display the relative information after enter to the location which need to be checked but the Code won t display RP208CN User s and Installer s Manual Page 30 ENTRY EXIT Program According to the operation as below you can enter into or exit the program state check location data change the location data and so on 1 Enter into program mode pres master code 2 Enter into the appointed location enter 2 digital location No ARM At this time the LCD will display the data of this location but the Code will not display 3 Enter into the next location press ARM 4 Change location data change the location data press to affirm The keypad will make a long sound beep to show operating right beep beep beep short sound show operating wrong 5 Exit programming mode input the master code ARM A Programming Tutorial To get acquainted with some programming basics a short tutorial has been prepared It involves changing the Installer Code from the factory default of 0 2 0 6 to a sequence of you own choosing If you can m
40. ntry and Exit Delays Your security system must incorporate in and from the premises without causing inadvertent alarms A delay period was chosen during your system s installation to provide suitable time to allow for your entry and exit Entry Exit Delays can be set by programming and it s defaulted as 30 seconds To change the delay time refer to location 11 13 of Chapter 5 16 24 Hour Zone RP208CN can support several kinds of zones All other forms of protection including fire and 24 hour panic alarms Le police fire and medical are always ready to report alarms and do not need to be armed 17 Trouble Display When the keypad sends out three short beep regularly indicating that the system exists some troubles When get rid of the troubles the system will restore to normal status and stop beeping Troubles include Battery Low AC power No Clock No Communication No Siren etc Press 3 to search on the LCD The troubles displayed as follow LCD Trouble Battery Low The Backup Battery Power is low AC Power AC Power is lost T le Tabl rouble Table No Clock Clock have not been set No Communication The Communication is in trouble No Siren The Siren connection is in trouble RP208CN User s and Installer s Manual Page 13 18 Zone Features RP208CN has 8 programmable zones Each zone can be programmed as Entry Exit Delay Zone Instant Intrusion Zone Panic Zone Fire Zone Tamper
41. ny other code should be entered manually follow the CMS software Digit Format Name Inter digit Time Date Frequency 01 Contact ID NA NA 03 default 442 Location 29 Preparation System Controls Location 30 Default 13 RP208CN User s and Installer s Manual Page 41 Location 30 allows you to specify some additional parameters which determine how the control panel will operate The location contains two digits Comments on system controls Location 30 1 Digit Quick Arm Eliminates the need for entering a User Code when arming to the STAY or AWAY modes Simply pressing STAY or ARM will arm the system to the respective mode Loudspeaker Bell Siren Select Loudspeaker if the external sounder s NOT equipped with a built in sound driver doing so causes the panel to produce an oscillating frequency for the device select Bell Siren if the external sounder s is a bell or a buzzer or equipped with a built in electronic sound driver Quick Bypass Eliminates the need to enter a User Code when bypassing a zone Silent Panic If NO the panic alarm will be AUDIBLE at the External Sounder and visual on the keypad If YES the panic alarm will be INAUDIBLE at the External Sounder and invisible on the keypad and there will be no audible kiss off Bell Squawk On Arming If selected Bell Squawk on Arming will produce a brief confirmation chirp from the system s external sounder s once the system is arme
42. o the central station All 10 codes including one Master Code and 9 User Codes can activate the Duress disarming by adding 1 to The last digit of your user codes The Duress Code and the User code share the first 3 digits Example User code 1 2 3 4 duress code is 1 2 3 5 User code 5 6 7 8 duress code is 5 6 7 9 User code 7 8 9 0 duress code is 7 8 9 1 Note Under no circumstances must the Duress Code be used haphazardly or without reason Central Stations along with Police Departments treat Duress Codes very seriously and take immediate action 11 Cutting off Sounder and Stop Auto dialing If outside premises open an entry door the keypad s will beep indicating that the Entry Delay period has begun The entry delay is defaulted as 30 seconds RP208CN User s and Installer s Manual Page 11 Silencing an alarm in progress Observe the keypad If any of the following conditions is evident an alarm has occurred The ARM LED is flashing 71 22 23 are displayed on the LCD It s best to enter the premises only after police or a security company has investigated and you feel confident that the burglar is no longer on your premises Disarming an armed system Before the Entry expires enter the four digits of your User Code NOTE If you make a mistake when entering your User Code the keypad will produce three short beeps and the LCD keypad will display error If so press ECS and re enter the Code 12 Bypassing
43. ode Location 08 10 Location 08 Installer Code Default 0206 The installer code used by installer authorized to modify the system s parameters It is recommended to change the factory default Installer Code to one of your own choice It is made up by 4 digits Default 0206 Location 09 Installer Code Il Default 1206 Same as the Installer Code 1 but with a few limitations It can t modify the default code observe and modify the first installer s codes modify any phone number nor observe amp modify MS lock code Location 10 Master Code Default 1234 PUPROSE to establish the keypad code for the system s chief user the Master Code provides the following special privilege 1 Alter the master code and users code 2 Setting the clock 3 Checking the trouble and the events record or other operation 4 System testing 5 Set follow me phone number Note the Master Code cannot be seen by the installer through the keypad System Time Locations 11 13 Location 11 Exit Delay Default 030 Location 11 is used to set the time of exit delay which unit is second The time of delay is made up of 3 digits 1 second at least 255 second at most For example 030 means the delay time is 30 seconds When arm it won t alarm to leave the RP208CN User s and Installer s Manual Page 33 locale in the time of exit delay Location 12 Entry
44. ormat according to a specific central station see the following First digit determine the number corresponding to the desired combination of Kiss off Handshake Freq Message Validation Extended Non Extended Format RP208CN User s and Installer s Manual Page 39 0 Second digit determine the number or letter corresponding to the desired Combination of Dialing Rate Inter digit Time Date Frequency Location 27 CS Protocols 1 Digit Stan Kiss off Handshake Message 1 Digit Form Freg Validation O default Non Extended 1400Hz jr Round ompare 1 Non Extended 2300Hz Bena pine Compare 2 Non Extended 1400Hz Parity 3 Non Extended 2300Hz Parity WA Dual Round 4 Extended 7 1400Hz Compare 5 Extended 2300Hz Dual Round Compare 6 Extended 1400Hz Parity 7 Extended 2300Hz Parity Location 27 CS Protocols 2 Digit 2 Digit Date Rate Inter digit Time Date Frequency O default 40 pulses sec 390ms 1800Hz 1 33 pulses sec 390ms 1800Hz 2 20 pulses sec 390ms 1800Hz 3 10 pulses sec 390ms 1800Hz 4 40 pulses sec 650ms 1800Hz 5 33 pulses sec 650ms 1800Hz 6 20 pulses sec 650ms 1800Hz 7 10 pulses sec 650ms 1800Hz 8 40 pulses sec 390ms 1900Hz 9 33 pulses sec 390ms 1900Hz A 20 pulses sec 390ms 1900Hz B 10 pulses sec 390ms 1900Hz C 40 pulses sec 650ms 1900Hz D 33 pulses sec 650ms 1900Hz E 20 pulses
45. ow unsteady alarm 161 RP208CN User s and Installer s Manual Page 47 special function urgency key press alarm 100 urgency key press Restore 100 Fire zone alarm 110 Fire zone Restore 110 Fire key press alarm 115 Fire key press Restore 115 Medical treatment emergency 120 alarm Medical treatment emergency 120 Restore menace alarm 121 Menace Restore 121 Fault reporting AC fault 301 AC Restore 301 Battery power low 302 Battery power Restore 302 Warning sign fault 321 Warning sign Restore 321 Fire zone fault 373 Fire zone Restore 373 On off reporting User arm 6A 401 User unarm 6A 401 User 0 quick arm unarm 62 408 Force arm 63 574 periodic test 64 602 RP208CN User s and Installer s Manual Page 48 RP208CN Customer A Address Installer Programming Worksheet City State Zip Customer Phone No Date of Installation Central Station Account No Installer s Comments Comments Location Description Entry Remark 00 01 02 Phone No CS 1 03 Phone No CS 2 04 05 CS Account No 06 07 08 Installer Code 1 09 Installer Code 2 10 Master Code 11 Exit Delay 12 Entry Delay 13 Bell cutoff Time 14 Zone 1 Settings 15 Zone 2 Settings 16 Zone 3 Settings 1
46. pass Restore Reporting 4 ABCD code 92 Zone 6 Bypass Restore Reporting 4 ABCD code 93 Zone 7 Bypass Restore Reporting 4 ABCD code 94 ek 8 Bypass Restore Reporting 4 ABCD RP208CN User s and Installer s Manual Page 46 RP208CN Control Panel Contact ID reporting codes Event reporting Contact ID Zone alarm unarm Report code Entry exit alarm 134 Entry exit Restore 134 Panic alarm 130 Panic Restore 130 24 hours zone alarm 133 24 hours zone Restore 133 Tamper zone alarm 137 Tamper zone Restore 137 Smoke induce zone alarm Restore 111 Fire zone alarm Restore 112 Waterproof zone alarm Restore 113 High temperature zone alarm 114 High temperature zone Restore 114 Pipeline zone alarm Restore 116 Fire zone alarm Restore 117 Warning sound alarm 122 Warning sign alarm 123 Perimeter zone alarm Restore 131 Interior zone alarm Restore 132 Daytime nights zone alarm Restore 135 Open zone alarm Restore 136 System zone alarm Restore 140 Detector tamper zone alarm Restore 144 24 hours zone alarm Restore 151 gas fired alarm 151 gas fired alarm Restore 151 Low temperature zone alarm Restore 152 temperature dissipate alarm Restore 153 Liquid leak alarm 154 Liquid leak Restore 154 Oil leak alarm Restore 155 Gas leak alarm Restore 157 High temperature alarm Restore 158 temperature dissipate alarm Restore 159 Airfl
47. ter Code this Code Can Create Duress Code Automatically 9 User Codes Each Code Can Create Duress Code Automatically Periodic Test e Offer Testing Report to Alarm Center Automatically Every Day Peripheral Equipment RP208CN User s and Installer s Manual Page 27 Voice module Remote Control Using for Disarm Arm and Emergency 0 Wireless Receiver Events Record 50 Events Record can be saved Timing Function Auto Daily Arm Auto Daily Test report Windows Disarm Arm Report Monitor Function Trouble Data can be Displayed on Keypad and Also can be Transmitted to Central Station Battery in Low Power Siren Circuit in Trouble AC Supply in Trouble System Clock is Not Set Tamper Prevention 0 Fire Alarm Circuit Trouble UO Port UO port can be activated when the system is Alarm Arm or Disarm Welcome check the location 22 in Chapter 5 for details Charging of Standby Battery Main Board attaches charging circuit the Standby Battery can be charged via BAT port TECHNICAL DATA Main Board Input power 16 5VAC 25VA via transformer RP208CN User s and Installer s Manual Page 28 Back up Battery DC12V 4Ah or DC12V 7Ah Auxiliary Power 12VDC 400mA maximum Siren port output Programmable output 12VDC 750mA maximum Open collector Active pull down 70mA max Switch zone output 250mA Circuit Response Time 500mS Fuse AUX Auxili
48. the new 4 digit code selected will emit a one second 4 confirming tone The selected User Code is now in effect For example press 5 1 6 7 8 5 If successful the keypad will emit a confirming tone Beep The selected User Code is now in effect Setting Changing 1 9 User Codes At times it may be desirable to completely delete a User Code Note that it is impossible to delete the Master Code although it can be changed Step Operation The system must be disarmed Enter the User Functions Mode and choose Codes 5 Press 5 Enter the current 4 digit Master Code For example 5 J 6 7 8 To set delete the User Code 1 press 1 To set delete the User Code 2 press 2 To set delete the User Code 3 press 3 The other Codes can be set deleted in the same way Enter the new User Code For example 3 3 5 5 If successful the keypad will emit a confirming tone Beep The selected User Code is now in effect Deleting User s Codes At times it may be desirable to completely delete a User Code Note that it is impossible to delete the Master Code although it can be changed Step Operation 1 The system must be disarmed Enter the User Functions Mode and choose Codes 5 Press 5 2 Enter the current 4 digit Master Code 5 6 7 8 RP208CN User s and Installer s Manual Page 8 To delete the User Code1
49. the standby power RP208CN User s and Installer s Manual Page 17 12 BAT the anode of the standby power 13 14 AC low tension entry port for AC power AC16 5V 15 the port for ground 16 BELL connect to the anode of detector 17 BELL connect to cathode of detector 18 UO Utility Outputs 19 20 AUX connect to the anode of detector s DC12V 22 25 28 31 COM the communal port In general the port COM should connect to of the anode of detector S DC12V and one port of the ALARM and TAMPER 21 Z1 the port for zone 1 defaults as Entry Exit Delay Zone Connect to one port of ALARM on the detector 23 24 Z2 for zone 2 and Z3 for zone 3 Defaults as Instant Intrusion Zone 26 Z4 the port for zone 4 defaults as Panic Zone Suit for connect with a panic button 27 Z5 the port for zone 5 defaults as fire zone Suit for connect with a Gas Detector or a Smoke Detector 29 Z6 the port for zone 6 defaults as tamper zone The user should connect it with one of the port TAMPER on detector 30 32 Z7 the port for zone 7 and Z8 zone 8 both of them are default ed as Interior Zone When arm by STAY the Interior Zone won t be armed 33 GRN the port should connect to the green line on the keypad 34 YRL the port should connect to the yellow line on the keypad
50. ystem always knows the status of any protected door window hallway room or area The main board of RP208CN is RP208MB The main features of RP208CN include the RP208KCL and RP208MB Main Features Of RP208KCL LCD can display the functions of system 3 Keypad Emergency Zones Panic 1 2 Fire 4 5 Medical 7 8 Key press with Audible Feedback LCD Backlight System Status Display LED Indication Alarm Power Armed Bypass Ready Tamper Tamper is Supervised Disarm by Code 9 Disarm by Remote Controller Disarm By Duress Code 0 LCD Display Bypassing and Not ready Zones e Quick Arm Quick Arm by Code Quick Stay Arm Stay Arm by Code Bypass zone quickly Bypass zone by Code RP208CN User s and Installer s Manual Page 26 Main Features of RP208MB Zones 8 programmable zones on Main Board Special zones Zone 5 Fire Zone default Zone 6 tamper Zone default 11 types of Programmable Zones 7 types of Voice Formats 9 Zone Terminal NC NO Single End with Resistor 2 2KQ End Calling Function Disarm Arm Report can be set Siren Driver Built in Siren Driver 750mA Clock 9 Built in Digital Clock Siren Voice Output Siren Voice type is Programmable Current output 750mA max Built in Digital Communicator Attached Digital Communicator Compatible with Contact ID 442 4 Follow me Phone Numbers 0 2 Central Station Numbers Code 1 Installation Code 1 Mas