Home
Intel Server System SR2625UR
Contents
1. Pin Signal Name Pin Signal Name 1 V_ IO RED_CONN_FP 26 Ground 2 V_IO GREEN_CONN_FP 27 Ground 3 V_ IO BLUE CONN_FP 28 Ground 4 V_IO HSYNC_BUFF_FP 29 Ground 5 V_IO VSYNC_BUFF_FP 30 Ground 6 N C 31 FP_THERM_SENSOR 7 N C 32 NC 8 N C 33 N C 9 N C 34 NC 10 N C 35 N C 11 FP_NMI_BTN_N 36 Ground 12 LED_NIC1_ACT_N 37 LED_NIC1_LINK_N 13 KEY 38 N C 14 FP_ID BTN_N 39 SMB_SEN_3VSB_CLK 15 Ground 40 SMB_SEN_3VSB_DAT 16 RST EP EIN N 41 LED NIC2 ACT N 17 NC 42 LED NIC2_ UNK N 18 FP_PWR_BTN_N 43 LED_FP_ID_N 19 SMB_IPMB_5VSB_CLK 44 Ground 20 SMB_IPMB_5VSB_DAT 45 LED_HDD_3V3_A 21 LED FP_PWR_N 46 FP_FLT_LED 5VSB 22 FP_PWR_LED_5VSB 47 LED_FP_SYS FLT2 N 23 RST_PWRGD_PS 48 LED_FP_SYS FLT1_N 24 LED_HDD_ACT_N 49 P5V 25 P5V_STBY 50 P5V_STBY 52 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS System Board Interconnects Table 40 SAS SATA Hard Drive Connector Pin outs J1B1 J2B1 J1B2 J2B2 J3B1 J4B1 J3B2 J4B2 Pin Signal Description SI Ground S2 SAS _TX_DP 0 4 S3 SAS TN DN 0 4 S4 Ground S5 SAS RX_DN 0 4 S6 SAS RX_DP 0 4 S7 Ground S8 Not Used S9 Not Used S10 Not Used 11 Not Used 12 Not Used 13 Not Used 14 Not Used P1 Not Used P2 Not Used P3 Not Used
2. Configuration 1 System integrated with an active SAS SATA midplane a redundant fan module and a 5 slot PCI Express riser SR2625URLX SR2625URLXT Configuration 2 System integrated with a passive midplane a non redundant fan module and a 3 slot PCI Express riser SR2625URBRP This chapter provides a high level overview of the system features Greater detail for each major system component or feature is provided in the following chapters Table 1 System Feature Set Feature Description Peripheral Interfaces External connections DB 15 video connector back RJ 45 serial Port A connector Two Ru 45 10 100 1000 Mb network connections Four USB 2 0 connectors back One USB 2 0 connector front Internal connections One USB 2x5 pin header which supports two USB 2 0 ports One low profile USB 2x5 pin header to support low profile USB Solid State drives One DH 10 Serial Port B header Six Serial ATA SATA Il connectors Two I O module connectors One RMM3 GCM4 connector to support optional Intel Remote Management Module 3 SATA Software 5 Activation Key connector One SSI EEB compliant front panel header One SSI EEB compliant 24 pin main power connector One SSI compliant 8 pin CPU power connector One SSI compliant auxiliary power connector Video On board ServerEngines LLC Pilot H Controller Integrated 2D Video Controller 32 MB DDR2 Memory LAN Two 10 100 100
3. PCI Riser Cards and Assembly Intel Server System SR2625UR TPS ROUND PAD ON SECONDARY SIDE NO COMPONENT ON SECONDARY SIDE 58 75 2 3131 7 50 19 1 976 53 75 2 116 42 19 1 661 40 03 1 576 32 03 1 261 MOI AAA AE 0 00 0 000 AX COMPONENT HEIGHT ON SECONDARY SIDE IS 3 80MW 0 0001 1 961 39 80 1 5611 0 00 49 80 123 91 4 679 134 67 5 302 Figure 47 2U PCI Express Passive Riser Secondary Side PRIMARY SIDE D8 26 0 325 GROUND PAD ON BOTH SIDES 6 00 0 235 53 50 10 138 8 26 0 325 NO COMPONENT NO TRACE ON SECONDARY SIDE ax R2 00 ES Se DETAIL A 10 079 SCALE 5 000 5 E O COMPONENT SEE DETAIL A 2 2 ON PRIMARY SIDE 10 16 10 4001 A R1 00 0 039 TYP 14 55 12 9351 AR 11 27 f 2x DR EREI 2x 66 00 2 5981 E 50 95 2 0061 NO COMPONENT ON PRIMARY SIDE 28 22 01 111 22 51 0 886 22 00 0 866 17 00 0 6691 5 2 50 S 0 098 i eet OA III 5 60 9 2201 lied ll ACUC ALL I COI HIN 3 50 0 138 0 00 0 0001 Da 1 90 0 075 Ab 1 57 0 0621 nan 1 90 0 075 0 50w10 0201 45 133 m EN m EH m m EZ 3 S S sas 2 g 23 amp 32 2 2 23 9 gt 2 s ee 3 he eas s e a e e e ES her 2 33 2 z8 S 2 22 gt 2 S BIR a aa e S das a ERS E gt ZS 25 2 0 Figure 48 2U Butterfly PCI X PCI Express Active Riser Primary Side 86 Enterprise Platforms and Services Division Intel ord
4. SAS SATA_1 HDD CONN SAS SATA_2 HDD CONN SAS SATA_3 HDD CONN SAS SATA_4 HDD CONN Y SAS SATA_S HDD CONN SAS SATA_6 HDD CONN SAS SATA_7 HDD CONN IPMB_SVSB_12C FLASH ROM LED FAULT HDD PRESENT SGPIO INTERFACE 64P CONN X 2 FROM MIDPLANE gt e USB TO SATA BRIDGE POWER SUPPLIER CONNECTOR 3 5 TAPE POWER CONNECTOR 4P LCP CONN S P CONTROL TO CONTROL PANEL BR PANEL CONN D gt 1X1 P USB CONN TO CONTROL PANEL BR D gt i 13P SATA SLIMLINE TO SLIM ODD DEVICE gt CONN USC RST Figure 37 SAS SATA Backplane Functional Block Diagram Revision 1 2 Intel order number E46130 005 65 Peripheral and Hard Drive Subsystem Intel Server System SR2625UR TPS 6 5 2 1 Enclosure Management Controller The backplane utilizes the features of the Vitesse VSC410 to implement several enclosure management functions The chip provides in band SAF TE and SES management and utilizes the following four I C interfaces 1 IC bus 0 is connected to an EEPROM which stores configuration and FRU data 2 C bus 1 is connected to an LM75 temperature sensor 3 DC bus 2 is connected to an IPMB bus from the server board 4 TC bus 3 is connected to an active midplane SAS controller 6 5 2 2 Hard Drive Activity and Fault LEDs The backplanes support an activity fault LED for each of the hard drive connector
5. CI 71 PET ESB_RX_DP_C2 72 GND 73 14 GND 74 GND no 76 PET_ ESB_RX_DP_C1 77 GND 81__PE1_ESB_AX_DP_CO 82 GND 89 9 GND GND GND 2 GND 3 8 E IN Je awo 38 NIC2_ACT_LED_N 98 FP PWR BTN N 39 LED STATUS GREEN BUF R1 99 FPD SWL 40 GND 100 GND 41 4 5 6 D 7 _ESB_ 8 _ESB_ ICI NAS IN 2 3 _ESB_ 4 _ESB_ 5 D 6 BIN 7 7 i 47 V IO BLUE CONN ER 107 FP_PWR_LED 3VSB 4 V_IO GREEN_CONN_FP 108 FP_ID LED R1_N 4 8 113 FAN_PWM_CPUI 4 el 5 6 Es 7 115 _FAN_PWM_CPU2 PCI_FAN_TACH10 116 PCI_FAN_TACH9 5 FAN_TACH8 117 FAN_TACH7 5 5 FAN_PWM3 114 GND 5 5 Revision 1 2 41 Intel order number E46130 005 System Board Interconnects Intel Server System SR2625UR TPS Pin Signal Name Pin Signal Name 58 FAN_TACH6 118 FAN_TACH5 59 FAN_TACH4_H7 119 FAN_TACH3_H7 60 FAN_TACH2_H7 120 FAN_TACH1_H7 Table 27 Midplane Fan Header Pin outs J2B1 FAN_1 J2B3 FAN_3 J7B1 FAN_5 4 P12V 7 GND FAN_PRSNTS_N 10_LED_FANS J2B2 FAN_2 J3B1 FAN_4 1 FAN_TACH6 1 FAN_TACH8 1 UNUSED 2 FAN PWM _CPU1 2 FAN PWM CPU2 FAN_PWM3 5 J7B2 FAN_6 P12V 3 P12V 3 P12V 4 2 P12V P12V 4 P12V 5 5 GND 5 GN 3 1 ED A 5 FAN_TACH2_H7 FAN_TACH4_H7 6 7 8 42 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Revision 1 2 P Table 28 Midplane Power Connector Pin out Pin Signal Description GND P3V3 P12V 7 wv w vs
6. O e LED mm Oio A Figure 40 Control Panel LEDs TP02112 The following table identifies each LED and describes its functionality Table 44 Control Panel LED Functions LED Color State Description NIC1 NIC2 On NIC Link WW Green B Activity Blink NIC Activity Bi w Greet On Legacy power on ACPI S0 state ower Sleep TH on standby power Blink Sleep ACPI S1 state Off Off Power off ACPI S4 or S5 state On Running normal operation Green 7 g i 5 E Blink Degraded ystem Status 7 on standby power Amber On j Critical or non recoverable condition Blink Non critical condition Off Off POST System Stop j B Green Random blink Provides an indicator for disk activity Disk Activity 3 7 Ge Off Off No hard disk activity SEI Blue On Identify active via command or button System Identification aes Off Off No Identification Notes 1 Blink rate is 1 Hz at 50 duty cycle 2 The amber status takes precedence over the green status When the amber LED is on or blinking the green LED is off 3 Off when the system is powered off S4 S5 or in a sleep state S1 4 The power LED sleep indication is maintained on standby by the chipset If the system is powered down without going through the BIOS the LED state that is in effect at the time of power off is restored when the system is powered on until the BIOS clears it If the system is not p
7. Product Overview Intel Server System SR2625UR TPS Table 5 Major Board Components Description Description A 280 pin Intel Adaptive Riser Card Slot Q Fan Board Connector Intel Server Chassis B POST Code LEDs R 2x4 Power Connector C Intel RMM3 Header S Main Power Connector D Processor 1 T Power Supply SMBus Connector E Back Panel I O U Fan Header F ID LED V USB Header G System Status LED Ww Intel Z U130 Value Solid State Driver Header H Fan Header X Fan Header Fan Header Y LCP IPMB Header J Processor 1 DIMM Slots Z OEM IPMB Header K Processor 2 DIMM Slots AA SGPIO Header L Processor 2 BB SATA Connectors M Fan Header CC I O Module Mezzanine Connector 2 N Fan Header DD I O Module Mezzanine Connector 1 O Bridge Board Connector Intel Server Chassis EE Serial Port B Header P Front Panel Connector A B C D S n E 9 ooooooo n H OO 0 G F E K AF002717 A Low profile PCle Add in Card Slots l NIC 2 B Full height PCI Add in Card Slots J NIC 1 C Upper Power Supply Module Fans K USB 6 D Upper Power Receptacle L USB5 E Lower Power Receptacle M DB 9 Serial B Connector F Lower Power Supply Module Fans N Video G Intel UO Expansion Module Optional O RJ 45 Serial A Connector H
8. 8 N C 33 N C 9 N C 34 N C 10 N C 35 N C 11 FP_NMI_BTN_N 36 Ground 12 LED_NIC1 ACT N 37 LED_NIC1_LINK_N 13 KEY 38 N C 14 IER ID BTN N 39 SMB_SEN_3VSB_CLK 15 Ground 40 SMB_SEN_3VSB_DAT 16 RST ER DINN 41 LED _NIC2 ACT_N 17 NC 42 LED _NIC2 UNK N 18 FP_PWR_BTN_N 43 LED_FP_ID_N 19 SMB_IPMB_5VSB_CLK 44 Ground 20 SMB_IPMB 5VSB_DAT 45 LED HDD 3V3 A 21 LED FP_PWR_N 46 FP_FLT LED 5VSB 22 FP_PWR_LED_5VSB 47 LED_FP_SYS_FLT2_N 23 RST_PWRGD_PS 48 LED_FP_SYS_FLT1_N 24 LED_HDD_ACT_N 49 P5V 25 P5V_STBY 50 P5V_STBY Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Intel Local Control Panel Table 54 Internal USB Header 6 Im GND a om s P usso 7 Revision 1 2 81 Intel order number E46130 005 PCI Riser Cards and Assembly Intel Server System SR2625UR TPS 9 PCI Riser Cards and Assembly The system supports different riser card options depending on the add in card configuration desired The riser assembly for the system is tool less Standoffs on the bracket allow the riser card to slide onto the assembly where a latching mechanism secures the riser in place Holding down the latch releases the riser for easy removal Figure 44 2U Riser Assembly 82 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS PCI Riser Cards and Assembly When re inserting the riser assembly into t
9. Intel order number E46130 005 Cooling Subsystem Intel Server System SR2625UR TPS 4 1 Non redundant Fan Module AF003107 Figure 15 Non redundant Fan Module This option provides the primary airflow for system configurations that do not require redundant cooling Table 20 Non redundant Cooling Zones System Fan 1 CPU2 Primary cooling for CPU 2 and Memory 1 System Fan 2 CPU1 Primary cooling for hard drives 4 and 5 CPU 1 memory 2 and the low profile PCI cards System Fan 3 PCI Primary cooling for hard drives 2 and 3 full height PCI cards and the Intel 5520 Chipset IOH Power Supply Power Primary cooling for hard drives O and 1 and the Fans 2 fans per Supply power supply module s module 30 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Cooling Subsystem The system fan module is designed for ease of use and supports several management features that can be utilized by the Integrated Baseboard Management Controller The fan module houses two different fan sizes System fans 1 and 2 use an 80 mm fan System fan 3 uses a 60 mm fan Each fan is designed for tool less insertion to or removal from the fan module housing For instructions on installing or removing a fan module see the Inte Server System SR2600UR SR2625UR Service Guide Note The fans are NOT hot swappable The system must be turned off in order to replace a failed fan Each fan wit
10. KS _INUSE TL GND og e og Te Standard Control Panel If a monitor is connected to the control panel video connector the rear video port on the server board is disabled and the control panel video is enabled The video source is the same for both connectors and is switched between the two with the rear video having priority over the control panel This provides easy front access to the server Revision 1 2 Intel order number E46130 005 73 Standard Control Panel Intel Server System SR2625UR TPS 7 4 Internal Control Panel Interconnect All control panel signals are routed through two cables as described above Both cables need to be plugged into the backplane after inserting the front panel Standard Control Panel PCB lt AF002786 Figure 41 Standard Control Panel PCB 74 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Standard Control Panel The following table defines the pin out for the 50 pin connector Revision 1 2 Table 49 50 pin Control Panel Connector J2B1 Signal Name Signal Name 1 VIO RED_CONN_FP 26 Ground 2 VIO GREEN_CONN_FP 27 Ground 3 V_IO BLUE CONN FP 28 Ground 4 VIO HSYNC_BUFF FP 29 Ground 5
11. P4 Ground P5 Ground P6 P3V3 P7 P5V P8 P5V P9 P5V P10 Ground P11 LED _SAS ACT_L 0 4 P12 Ground P13 P12V P14 P12V P15 P12V PTHO Ground PTY1 Ground 53 Revision 1 2 Intel order number E46130 005 Peripheral and Hard Drive Subsystem Intel Server System SR2625UR TPS 6 Peripheral and Hard Drive Subsystem The system can be configured to support several different hard drive and peripheral configurations The peripheral hard drive subsystem consists of a drive bay supporting a slimline optical drive hard drives and a flex bay a midplane and a hot swap backplane This chapter describes the details for each subsystem component o00000 o00000 OOOOOO0O OOOOOO00O AF002782 Flex Bay Tape Drive or two fixed 2 5 inch Hard Drives Optional System Control Panel Slimline SATA Optical Drive Bay 2 5 inch Hard Drive Bays 8 Dom gt Figure 27 Flex bay for 3 5 inch Tape Drive or Two 2 5 inch HDDs Front View 6 1 Slimline Drive Bay The system provides a slimline drive bay that is designed to support a single slimline SATA optical drive For a list of support
12. The function of each control button is listed in the following table 68 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Standard Control Panel O OQ CS S O O U TP02111 Figure 39 Control Panel Buttons Table 43 Control Button and Intrusion Switch Functions A Power Toggles the system power on off This button also functions as a Sleep Sleep Button Button if enabled by an ACPI compliant operating system ID Button Toggles the front panel ID LED and the server board ID LED on off The server board ID LED is visible through the rear of the system and allows for server identification and location when working behind a rack of servers Reset Button Reboots and initializes the system NMI Button When the NMI button is pressed with a paper clip or pin it puts the server in a halt state for diagnostic purposes and allows the issuance of a non maskable interrupt After issuing the interrupt a memory download can be performed to determine the cause of the problem 7 2 Control Panel LED Indicators The control panel houses six LEDs to display the system s operating state The LEDs are visible with or without the front bezel Revision 1 2 69 Intel order number E46130 005 Standard Control Panel Intel Server System SR2625UR TPS Power and Hard Drive Sleep LED Activity LED NIC1 and NIC2 System Activity LEDs E LED S HE HE D Q
13. 2 Intel order number E46130 005 49 System Board Interconnects Intel Server System SR2625UR TPS Table 37 PCI Express X4 Slot Connector from Midplane J4N1 Pin 4 Signal Name Pin Signal Name A1 SGPIO_DATAO B1 SGPIO_CLOCK A2 SGPIO_DATA1 B2 Ground A3 Ground B3 SAS6_RX_DN A4 Ground B4 SAS6_RX_DP A5 SAS7_RX_DN B5 Ground A6 SAS7_RX_DP B6 Ground A7 Ground B7 SAS6_TX_DN A8 Ground B8 SAS6_TX_DP A9 SAS7_TX_DP B9 Ground A10 SAS7_TX_DN B10 Ground A11 Ground B11 SGPIO_LOAD A12 SMB_PB1_5VSB_DAT B12 SMB_IPMB_5VSB_DAT A13 SMB_PB1_5VSB_CLK B13 SMB_IPMB_5VSB_CLK A14 USB_OC1_N B14 Ground A15 Ground B15 USB_P2P A16 Ground B16 USB _P2N A17 USB_P1P B17 Ground A18 USB_P1N B18 Ground A19 Ground B19 USB_OC2_N A20 LED_NIC1_ACT_L B20 LED HDD ACT RL A21 LED_NIC1_LINK_R_L B21 PV_HDD_LED 3V_A A22 FP_THERM_SENSOR B22 ER ID SW L A23 LED_NIC2_LINK_R_L B23 RST_FP_BTN_L A24 LED_NIC2_ACT_L B24 FP_PWR_BTN_L A25 Ground B25 FP_NMI_BTN_L A26 V_IO BLUE_CONN_FP B26 FP_PWR_LED_5VSB A27 V_IO_ GREEN_CONN_FP B27 LED EP DW RL A28 V_IO_RED_CONN_FP B28 LED FP_LID RL A29 Ground B29 Ground A30 V_IO_HSYNC_BUFF_FP_L B30 LED _FP_SYS FLT1_RL A31 V_IO VSYNC_BUFF_FP_L B31 LED FP_SYS FLT2 RL A32 Ground B32 FP_FLT_LED_5VSB 50 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Sys
14. AG Line Dropouts CUP EE 26 Revision 1 2 Intel order number E46130 005 Table of Contents Intel Server System SR2625UR TPS 3 8 4 AC Line 5 VSB Holdup E 26 3 8 5 dill n EE 26 3 9 Protection Cile u S sas kk ya ya ka lek ii bek ek n ee RR k HAA 26 3 9 1 Over current Protection OCP amianto 26 3 9 2 Over voltage Protection OVP resaltadas 27 3 93 Over temperature Protection OT 27 3 10 DG OUIDUT Specific ON scroll 28 3 10 1 Output Power Currents serge ches olaaa kk k ke kk KK see 28 3 10 2 Standby Output Standby Mode kek kk kk k k kk KA 28 3 11 Power Supply Status LED AEN 28 4 Cooling SUD SON as 29 4 1 Non redundant Fan Module asii Edge 30 4 2 Redundant System Fan Module kk 33 4 3 ele de 35 4 3 1 Power Supply ZOMG rana a is 35 4 3 2 A E 35 4 3 3 CPU Memory Low profile PCI Zone EEN 36 4 4 Drive Bay POpUlatiOn tucan de 37 4 5 Memory Slot Population DEE 37 4 6 Sata ADOS PP e toa 38 5 System Board Interconnects ii Eed 39 5 1 elei uan iia 39 5 2 Bridge BOO WEE 46 5 3 Hot swap SAS SATA Backplane hE Ek kek kk Kek K kk k ke 47 6 Peripheral and Hard Drive Subsystem oooommnccccnnnncccccnnnnnncnnnnnncnnnnnnnn E kak keka nera 54 6 1 Slimline Drive EE 54 6 2 Hard Drive EE 55 6 2 1 Hot swap Drive TEE 55 6 3 Optional Tape Drive or Additional Hard Drives Flex Bay 57 6 4 Midplane Optlons is 58 6 4 1 Passive le Tel tots tad dere Guoue EPan ES 58 6 42 Active Midplane with SAS SAS RAID Gupport
15. Currents The following table defines power and current ratings for this 750 W continuous 860 W pk power supply in 1 0 or 1 1 redundant configuration The combined output power of both outputs does not exceed the rated output power The power supply must meet both static and dynamic voltage regulation requirements for the minimum loading conditions Also the power supply is able to supply the listed peak currents and power for a minimum of 10 seconds Outputs are not required to be peak loaded simultaneously Table 18 Output Power and Current Ratings IN ANNAN TT Te TT 70 0 A 12 seconds 5 0A 0 5 seconds minimum minimum turn on maximum ar RR V x 70A5840Wek EVGA 25 WA 3 10 2 Standby Output Standby Mode The 5 VSB output is present when an AC input greater than the power supply turn on AC voltage is applied Applying an external 5 25 V to 5 VSB does not cause the power supply to shut down or exceed operating limits When the external voltage is removed the voltage returns to the power supplies operating voltage without exceeding the dynamic voltage limits 3 11 Power Supply Status LED Each power supply module has a single bi color LED to indicate power supply status The LED operation is defined in the following table Table 19 LED Indicators Power Supply Condition Bi Color LED No AC power to all power supplies Off No AC power to this PSU only for 1 1 configuration or Power supply critical event causing a s
16. Disclaimer citada 2 25 Prod ct OVERVIOW oi iio aida 3 2 1 1 PIOCOSSOM SUD DOM sonal 5 2 2 SYSTEM OVEMVIOW 2zr p e eo eMAAM MAMA MA AM RTR Ra aa 7 2 3 System REEL EE 7 2 4 System Gompohe nS eta li 8 2 5 Hard Drive and Peripheral Bays u Ek kk kK KK KAKA KA 9 2 6 System Board Re d EE 10 2 7 Front Bezel Features ck ll da dll ea Aana EEEE ki kulek P kv kebk eken eke eias 14 2 8 Rack and Cabinet Mounting Options EEL kk kk kk KH 15 2 9 Trusted Platform Module TPM Supported only on SR2625URLXT 15 2 9 1 OVEIVIGW Ss ele See EENS EE 15 29 2 o TPM s c rity BIOS erradicar 16 3 POWER Subsystem io iia 19 3 1 Mechanical OVNIS TEE 19 3 2 Single Power Supply Module Populatton kk kek 21 3 3 Handle and Retention Mechani SIm u EEE kK KK KK 21 3 4 Hot swap SUpport EE 21 3 5 A A 22 3 6 AC Power Cord Specification Requirement oooocccccocccononcnoccnnnnanccnnnonancnnnnnnnnncnnnnns 22 3 7 O tp t Gable Mames 22 3 7 1 P1 Server Board Power Connector cccscccceeeesecceeeeeseeeeeeesseeeeeeeneeseeteesnnaees 23 3 7 2 P2 Processor Power Connector mericccersisiir laa race 23 3 7 3 P3 Power Signal ConnectOr ELiE Ek kk kek kk Kek de EE 24 3 7 4 P4 Backplane Power Connect 24 3 7 5 P5 Midplane Power OI eege a 24 3 8 AC Input Requirements E 25 3 8 1 ETICA EEN 25 3 8 2 AG Input Voltage opecifica ON a a 25 3 8 3
17. Ek ke 59 6 5 Hot swap SAS SATA Backplane AEN 62 6 5 1 SAS SATA Backplane LayoOUt EEEEE Eke kk kek K k kK K k kK A 62 6 5 2 SAS SATA Backplane Functional Architecture 65 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Table of Contents 6 6 Enclosure Management Cabling for Passive Midplane 67 T Standard Control Panel ius ae aaa dl nede Ee een 68 7 1 Control Panel Gian S e 68 7 2 Control PanellbEDINdiCato Sia eres cy cee ened Sepa anes 69 7 2 1 Power Sleep LE Dzayi ans nanan e a ia 71 7 2 2 System Stat s LED EE 71 7 2 3 Drive Activity LED osa o 72 7 2 4 System Be Enge en H nenen KA 72 7 3 Control Panel e E 73 7 4 Internal Control Panel Interconnect ANEN 74 8 intel Local Control Panel A inin A A AE at 76 8 1 LED ele EE 77 8 1 1 Power lso PEDO asta io des dilo SERENA td 78 8 1 2 System Status LED aia 78 8 1 3 Ree e BED EE 79 8 1 4 System ldentification LED pda ida 79 8 2 Intel Local Control Panel Interconnects ccccsesesssesssssseseseserscecesssseseateenscecesenes 80 9 PCI Riser Cards and Assembly ccccsesseeeeeeeseeeeeeseeeeeeeeeseeeeesesneeeeeesseeaeeeeenseeeeeeenesneees 82 9 1 Riser Gard Options en eree ts 84 9 2 PCI Riser Card Mechanical Drawings oooocccccnnnocccccccococccononanncn conan cnn nnnnnccnnnnnncnn 85 10 Environmental Specifications oomooccconnnnnncnnnnncccnccnna
18. Intel Remote Management Module 3 NIC Optional Figure 6 Back Panel Feature Overview 12 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Product Overview 2 dira LR O 209 H ap 99 E Eog ii O E M M M 10 M El Ii Ii O e AF002833 POST Code Diagnostic LEDs CPU 1 DIMM Fault LEDs B System Identificatio
19. Key enables the full intelligent SAS Hardware RAID solution The activation key plugs directly into a connector J1A10 on the midplane board With no RAID activation key installed only SAS Software RAID levels 0 1 and 10 are supported 6 4 2 4 2 Intel RAID Cache support To further enable support for hardware RAID the active midplane provides a 244 pin mini DIMM connector J8C1 supporting a single registered ECC non parity DDR2 400 MHz Mini DIMM to provide Intel RAID cache Supported mini DIMM capacities range from 128 MB to 1 GB Note For a list of Intel validated mini DIMMs use the Server Configurator Tool available at http serverconfiqurator intel com default aspx 6 4 2 4 3 Intel RAID Smart Battery Backup Module With an Intel RAID Smart Battery Backup module installed data loss is prevented when data is still present in the RAID Cache Module and power is unexpectedly lost Depending on the cache module capacity used the battery backup unit can provide 48 to 72 hours of battery backup power to allow data stored in the RAID cache to be processed A 2x10 connector J9A2 is used to attach the battery backup unit to the midplane For details see Revision 1 2 61 Intel order number E46130 005 Peripheral and Hard Drive Subsystem Intel Server System SR2625UR TPS Table 31 6 5 Hot swap SAS SATA Backplane The SR2625 system supports its own multifunctional SAS SATA backplane with the following features Vitesse VS
20. O O O xX X X X O Reserved for initialization module use PEIM OxE2h O O O xX X X O xX Initial memory found configured and installed correctly OxE3h O O O X X X O O Reserved for initialization module use PEIM Driver eXecution Environment DXE Core not accompanied by a beep code OxE4h O O O xX X O X X Entered EFI driver execution phase DXE OxE5h OOO X X O X O Started dispatching drivers OxE6h O O O X X O OD X Started connecting drivers DXE Drivers OxE7h O O O X JO O X O Waiting for user input OxE8h O O O X Jo X X X WChecking password OxE9h O O O X Jo X X Entering BIOS setup OxEAh O O O X Jo xX O xX Flash Update OxEEh O O O X JO O X Calling Int 19 One beep unless silent boot is enabled OxEFh O O o X Jo o o o Unrecoverable boot failure Runtime Phase EFI Operating System Boot Revision 1 2 105 Intel order number E46130 005 Appendix B POST Code Diagnostic LED Decoder Intel Server System SR2625UR TPS Diagnostic LED Decoder O On X Off Checkpoint Upper Nibble Lower Nibble Description MSB LSB 8h 4h 2h 1h 8h 4h 2h 1h LED 7 6 5 4 3 2 1 0 OxF2h O O O O X X o X Signal that the OS has switched to virtual memory mode OxF4h O O O O IX O X X Entering Sleep state OxF5h O O O o Jx O X 0 Exiting Sleep state OS has requested EFI to close boot services ExitBootServices Has OxF8h OOO O Jo X X X been called OS has switched to virtual address mode SetVirtualAddressMa
21. Pause 8521 Pause 8522 Pause 8523 Pause 8524 Pause 8525 Pause 8526 Pause 8527 Pause 8528 Pause 8529 Pause 852A Pause 8528 Pause 8520 Pause 852D Pause 852E Pause 852F Pause 8540 Pause 8541 Pause 8542 Pause 8543 Pause 8544 Pause 8545 Pause 8546 Pause 8547 Pause 8548 Pause 8549 Pause 854A Pause 8548 Pause 854C Pause 854D Pause 854E Pause 854F Pause 8560 Pause 8561 Pause 8562 Pause 8563 Pause 8564 Pause 108 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Appendix C POST Code Errors 8565 8566 8567 8565 8569 856A 856e 856C 856D 856E 856E 8580 8581 8582 8583 8584 8585 8586 8587 8585 8589 858A 8588 858G 858D Pause Revision 1 2 109 Intel order number E46130 005 Appendix C POST Code Errors Intel Server System SR2625UR TPS 92A9 92C6 9207 9208 9408 94C9 9506 95A6 95AT 95A8 9609 9641 9667 9687 96A7 96AB 96E7 OxA022 0xA027 0xA025 0x421 0xA500 Aen 0xA5A0 Aen POST Error Beep Codes The following table lists the POST error beep codes Prior to system video initialization the BIOS uses these beep codes to inform users on error conditions The beep code is followed by a user visible code on the POST Progress LEDs For complete details refer to the InteP S5500 S5520 Server Board Family BIOS External Product Specification Table 61 POST Error Beep Codes Memory error Lie OxEB OxED Se TET halted because
22. Pin out Signal Description P12V GND 4 GND e f Tono Pre VBAT RAID GND GND GND 18 BBU_BBE Table 32 Passive Midplane SATA SAS Connector Pin outs GND GND GND GND GND GND GND GND GND GND GND GND Revision 1 2 45 Intel order number E46130 005 System Board Interconnects Intel Server System SR2625UR TPS 5 2 Bridge Board The system utilizes a bridge board to route signals from the server board to the midplane board The bridge board carries signals for three USB ports SSI front panel control signals video various DC buses fan control signals and a PCI Express x4 bus for SAS controller function For details see Table 26 AF000037 Figure 24 Bridge Board 46 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS System Board Interconnects 5 3 Hot swap SAS SATA Backplane The hot swap backplane provides support for both SAS and SATA hard drives There are no hard drive cables that connect to the backplane All hard drive control signals are routed from the midplane board which plugs directly into the backplane AF002788 A SAS SATA hot swap Connectors B Slimline optical drive Connector Figure 25 2 5 inch Hot swap SAS SATA Backplane Front Side View Revision 1 2 47 Intel order number E46130 005 System Board Interconnects Intel Server System SR2625UR
23. TPS AF002789 A Conitrol Panel Connector D Power Connector 10 pin Front Panel USB Connector E Midplane Connectors C Power Connector for SATA Tape Drive or additional 2 5 inch drives Gi Figure 26 2 5 inch Hot swap SAS SATA Backplane Back Side View Table 33 2x4 SAS SATA Backplane Power Connector Pin out J8L1 Pin Signal Name 1 Ground Ground P5V P5V P12V P12V P5V_STBY P3V3 CO N 9 aj A Q N 48 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS System Board Interconnects Table 34 1x7 Tape Drive Option Power Connector Pin out J2N2 Pin Signal Name 1 P12V Ground Ground P5V SASS_PRSTNT_L LED_SASS_ACT_L N Om BY Q N P3V3 Table 35 Slimline Optical Drive Slot Connector J6C1 Pin Signal Name S1 GND S2 SATA_TXP S3 SATA_TXN S4 GND S5 SATA_RXN S6 SATA_RXP S7 GND KEY P1 N C P2 P5V P3 P5V P4 N C P5 GND P6 GND Table 36 I C Connector J2M2 located on the back side of the backplane Pin Signal Description 1 SMB_VSC_I2C_DATO GROUND SMB_VSC_l2C_CLKO 2 3 4 TP_l2C_CONN_P4 Revision 1
24. USBX3 PORT i gl 2 4 1 2 la 3 3 gt FAN TECH amp PWM jar 2 gt 0 O O O O O N LJ NA N en ez LED 3 a LEDS 120 PIN CONNECTOR Figure 34 Architecture Overview 6 4 2 2 x4 PCI Express Card Edge Interfaces Two x4 PCI Express card edges are used to connect the active midplane to the hot swap backplane The use of card edge connectors to the backplane eliminates all hard drive cabling 6 4 2 3 LSI LSISAS1078 ROC The LSI LSISAS1078 ROC supports transfer rates of up to 3 GB s on each SAS port It integrates a high speed DDR DDR2 SDRAM interface for Hardware RAID cache It utilizes a PCI Express interface to provide transmission and reception rates of up to 10 GB s over a x4 link from ICH10R through the bridge board 60 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Peripheral and Hard Drive Subsystem 6 4 2 4 Optional Hardware RAID Support The active midplane supports options to provide full hardware RAID support Options required to enable hardware RAID support include an Intel RAID Activation Key Product Order Code AXXRAKSAS2 and installation of a Mini DIMM for Intel RAID Cache support To protect from data loss during an unexpected power loss event an Intel RAID Smart Battery Backup module AXXRSBBU3 is also supported Hardware RAID levels supported include 0 1 5 6 10 50 and 60 6 4 2 4 1 Intel RAID Activation Key The Intel RAID Activation
25. V output to shut down or cause a shutdown of any of the three outputs on the PDB Any one of these shutdowns results in shutting down the entire power supply PDB combination If the power supply latches off due to a protection circuit tripping an AC cycle OFF for 15 seconds resets the power supply and the PDB 3 9 1 Over current Protection OCP Each DC DC converter output on the PDB has individual OCP protection circuits The power supply and power distribution board PS and PDB shut down and latch off after an over current condition occurs This latch is cleared by toggling the PSON signal or by an AC power interruption The over current limits are measured at the PDB harness connectors 26 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Power Subsystem The DC DC converters are not damaged from repeated power cycling in this condition The 12 V output from the power supply is divided on the PDB into four channels and each is limited to 240 VA of power Current sensors and limit circuits shut down the entire PS and PDB if the limit is exceeded The limits are listed in the following table Table 16 Over current Protection Limits 240 VA Protection 110 min 26 4 A min 150 max 36 A max 5 V 110 min 33 A min 150 max 45 A max 125 min 0 625 A min 400 max 2 0 A max 125 min 18 0 A min 112 5 min 18 0 min 3 9 2 Over voltage Protec
26. V_IO VSYNC_BUFF_FP 30 Ground 6 N C 31 FP_THERM_SENSOR 7 NIC 32 N C 8 N C 33 N C 9 N C 34 N C 10 N C 35 N C 11 FP_NMI_BTN_N 36 Ground 12 LED_NIC1_ACT_N 37 LED_NIC1_LINK_N 13 KEY 38 N C 14 FP_ID_BTN_N 39 SMB_SEN_3VSB_CLK 15 Ground 40 SMB_SEN_3VSB_DAT 16 RST_FP_BTN_N 41 LED NIC2 ACT_N 17 N C 42 LED NIC2_LINK_N 18 FP_PWR_BTN_N 43 LED ER IDN 19 SMB_IPMB_5VSB_CLK 44 Ground 20 SMB_IPMB_5VSB_DAT 45 LED HDD 3V3_A 21 LED FP_PWR_N 46 FP_FLT LED 5VSB 22 FP_PWR_LED_5VSB 47 LED FP_SYS FLT2 N 23 RST_PWRGD_PS 48 LED _FP_SYS_FLT1_N 24 LED HDD ACT_N 49 P5V 25 P5V_STBY 50 P5V_STBY Intel order number E46130 005 75 Intel Local Control Panel Intel Server System SR2625UR TPS 8 Intel Local Control Panel The Intel Local Control Panel utilizes a combination of control buttons LEDs and LCD display to provide system accessibility monitoring and control functions The pre assembled module slides into a slot on the front of the system and connects with cables to matching connectors on the backplane The Intel Local Control Panel module is designed so that it can be adjusted for use with or without an outer front bezel TP02113 Figure 42 Intel Local Control Panel Assembly Module The following diagram provides an overview of the control panel features B rmn pD l E r Week gie O l M L K J H G TP02099 A USB 1 1 Port l Sys
27. X O xX X X O xX Reading configuration data from memory SPD on DIMM 0x23h X X O xX X X O O Detecting presence of memory 0x24h X X O X X O xX X Programming timing parameters in the memory controller 0x25h X X O xX X O xX O Configuring memory parameters in the memory controller 0x26h X X O xX X O O X Optimizing memory controller settings Revision 1 2 103 Intel order number E46130 005 Appendix B POST Code Diagnostic LED Decoder Intel Server System SR2625UR TPS Diagnostic LED Decoder O On X Off Checkpoint Upper Nibble Lower Nibble D seripil ni MSB LSB 8h 4h 2h th 8h 4h 2h 1h LED 7 6 5 4 3 2 1 0 0x27h X X DM O O Initializing memory such as ECC init 0x28h X X O xX O xX X X Testing memory PCI Bus 0x50h X O xX O IX X X X Enumerating PCI busses 0x51h x O X O X X X Oo Allocating resources to PCI busses 0x52h x O X O XX X O X Hot Plug PCI controller initialization 0x53h x O X O X X O O Reserved for PCI bus 0x54h x O X O X O X X Reserved for PCI bus 0x55h x O X O X O X O Reserved for PCI bus Ox56h X O X O X O O X J Reserved for PCI bus 0x57h X O X Of X O O O J Reserved for PCI bus USB 0x58h x O X O JO X X X Resetting USB bus 0x59h x O X O Jo X X O Reserved for USB devices ATA ATAPI SATA Ox5Ah x O X O e XKX O xX Resetting SATA bus and all devices 0x5Bh X o X o IO X O O Reserved for ATA SMBUS 0x5Ch x O X O Jo O X X Resetting SMBUS 0x5Dh x O X O O O X O Rese
28. a fatal error related to the memory OxEE was detected The Integrated BMC may generate beep codes upon detection of failure conditions Beep codes are sounded each time the problem is discovered such as on each power up attempt but are not sounded continuously Codes that are common across all Intel server boards and systems that use same generation chipset are listed in the following table Each digit in the code is represented by a sequence of beeps whose count is equal to the digit For complete details 110 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Appendix C POST Code Errors refer to the Inte Server System Integrated Baseboard Management Controller Core External Product Specification Table 62 Integrated BMC Beep Codes Reason for Beep Associated Sensors Supported 1 5 2 1 No CPUs installed or first CPU socket is CPU Missing Sensor Yes empty 1 5 4 2 Power fault DC power unexpectedly lost Power unit power unit failure Yes power good dropout offset 1 5 4 4 Power control fault power good assertion Power unit soft power control Yes timeout failure offset Revision 1 2 111 Intel order number E46130 005 Glossary Intel Server System SR2625UR TPS Glossary ACA ACP ANS m m m JU DI a O TI iw Mean Time Between Failure Mean Time to Repair Mean Time 9 Fegar TT y O Redundant Array of Independent or Inexpe
29. displays The following message displays on the diagnostics screen and under the Quiet Boot logo screen Press lt F2 gt to enter setup When the Setup is entered the Main screen displays The BIOS Setup utility provides the Security screen to enable and set the user and administrative passwords and to lock out the front panel buttons so they cannot be used The Intel Server Board S5520URT provides TPM settings through the security screen To access this screen from the Main screen select the Security option Main Advanced Security Server Management Boot Options Boot Manager Administrator Password Status lt Installed Not Installed gt User Password Status lt Installed Not Installed gt Set Administrator Password 1234aBcD Set User Password 1234aBcD Front Panel Lockout Enabled Disabled lt Enabled amp Activated Enabled amp Deactivated Disabled amp TPM State Activated Disabled amp Deactivated gt TPM Administrative Control No Operation Turn On Turn Off Clear Ownership Figure 11 Setup Utility TPM Configuration Screen Revision 1 2 17 Intel order number E46130 005 Product Overview Intel Server System SR2625UR TPS Table 6 TSetup Utility Security Configuration Screen Fields Setup Item Options Help Text Comments TPM State Enabled and Activated Information only Enabled and Deactivated Shows the current TPM device state Disabled and Activated Disabled and Deactivat
30. error condition and responds as follows Logs the error into the system event log SEL Alerts the Integrated BMC of the configuration error with an IPMI command Does not disable the processor Displays 0194 Processor family mismatch detected message in the error manager Halts the system Processor cache not Fatal The BIOS detects the error condition and responds as follows identical Logs the error into the SEL Alerts the Integrated BMC of the configuration error with an IPMI command Does not disable the processor Displays 0192 Cache size mismatch detected message in the error manager Halts the system Processor frequency speed Major The BIOS detects the error condition and responds as follows not identical Adjusts all processor frequencies to lowest common denominator Continues to boot the system successfully If the frequencies for all processors cannot be adjusted to be the same then the BIOS Logs the error into the SEL Displays 0197 Processor speeds mismatched message in the error manager Halts the system Processor microcode Fatal The BIOS detects the error condition and responds as follows missing Logs the error into the SEL Alerts the Integrated BMC of the configuration error with an IPMI command Does not disable processor Displays 816x Processor 0x unable to apply microcode update message in the error manager Pauses the system for user intervention Processor
31. lt Ba WB e e N BA Se a J N A Be lt Se NR Ba PA Z UN SST Ue ae N Pa LU y Dk A Le AF002740 Figure 19 CPU Air Duct with Air Baffle Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Cooling Subsystem 4 4 Drive Bay Population To maintain the proper air pressure within the system all hard drive bays must be populated with either a hard drive or drive blank AF002779 Figure 20 2 5 inch Drive Carrier with a Blank 4 5 Memory Slot Population To maintain proper airflow over the DIMMs and CPUs DIMMs or DIMM blanks must be populated The requirements are as follows One CPU installed All CPU 1 DIMM slots must either have a DIMM or DIMM blank installed You may leave the CPU 2 DIMM slots empty or store extra DIMM blanks in the blue DIMM slots Two CPUs installed All blue DIMM slots in CPU 1 and CPU 2 must either have a DIMM or DIMM blank installed You may store extra DIMM blanks in any unused CPU DIMM slots Figure 21 DIMM Blank Revision 1 2 37 Intel order number E46130 005 Cooling Subsystem Intel Server System SR2625UR TPS 4 6 Sata HDD Support Due to the rotational velocity and vibration impacts that fans have on hard drives fan redundancy is only supported when using SAS hard drives Additionally the maximum supported temperatures when using SATA drives have been affected as follows e At 1500 m 5000 ft the maxim
32. memory in the system or SPD bad so SE Tez e GR Z X no memory could he detected OxEAh OOO x lo x o x Channel Training Error DQ DQS training failed on a channel during memory channel initialization OxEBh OO O xX O xX O O Memory Test Error memory failed Hardware BIST OxEDh o o lo x o o x o n Error RDIMMs and UDIMMs cannot be mixed in the OxEEh O O O X JO O O X Mismatch Error more than 2 Quad Ranked DIMMS in a channel Memory Reference Code Progress Codes Not accompanied by a beep code 0xBOh O X O O X X X X Chipset Initialization Phase OxBth O X O O IX X X O Reset Phase 0xB2h O xX O O px X O xX DIMM Detection Phase OxB3h O xX O O x X O O Clock Initialization Phase 0xB4h O X O O X O X X SPD Data Collection Phase OxB6h O xX O O px O O X Rank Formation Phase 0xB8h O xX O O O xX X X Channel Training Phase OxB9h O X O O lO X X 0 Memory Test Phase OxBAh O xX O O O xX O xX Memory Map Creation Phase OxBBh O xX O O O xX O O BAG Initialization Phase OxBFh O X O O Jo O Oo OO IMRC Complete Host Processor 0x04h X X X X X O X X Early processor initialization where system BSP is selected 0x10h X X X O IX X X X Power on initialization of the host processor bootstrap processor 0x11h X X X O IX X X O Host processor cache initialization including AP 0x12h X X X O px X O xX Starting application processor initialization 0x13h X X X O px X O SMM initialization Chipset 0x21h X X O xX X X X O Initializing a chipset component Memory 0x22h X
33. of Conformity This product has been tested in accordance too and complies with the Low Voltage Directive 73 23 EEC and EMC Directive 89 336 EEC The product has been marked with the CE Mark to illustrate its compliance 11 5 4 VCCI Japan COME HPS SORA ARIAS VCCI DM KEK 7 52 A BIRNE BOT CORBERA SC BR xir 2 3l R Z32 k i00 SS C OB Ek EE R2 00d DERE 24X45 5R 112 n English translation of the notice above This is a Class A product based on the standard of the Voluntary Control Council for Interference VCCI from Information Technology Equipment If this is used near a radio or television receiver in a domestic environment it may cause radio interference Install and use the equipment according to the instruction manual 98 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Regulatory and Certification Information 11 5 5 BSMI Taiwan The BSMI Certification Marking and EMC warning is located on the outside rear area of the product ERAZ nak mi SA Me d sa ed m ea IBE N AK HE ER gt AE REZ WER JERE AMER 11 5 6 KCC Korea Following is the KCC certification information for Korea Zan 1 21212 J amp J Mi 2 ISHS 3 Red AL Bs e 4 SCH 5 MAY METI English translation of the notice above Type of Equipment Model Name On Certification and Product Certification No On KCC certificate Obtai
34. or midplane to enable fault LED control The cable is included with your integrated system or the backplane or midplane kit In Intel Server System SR2625URBRP the 3 pin white HBA CONN connector on the passive midplane should be used IMPORTANT No cable is required for fault LED control when using the on board SAS or SATA RAID controller No cable is required for fault LED control when using an active backplane or midplane In these configurations connecting a 3 pin IC cable to the backplane or midplane may cause unexpected system behavior Revision 1 2 67 Intel order number E46130 005 Standard Control Panel Intel Server System SR2625UR TPS 7 Standard Control Panel The standard control panel supports several push buttons status LEDs USB and video ports to centralize system control monitoring and accessibility within a common compact design The control panel assembly comes pre assembled and is modular in design The control panel assembly module slides into a slot on the front of the system and is then cabled to the backplane using a 50 pin flap cable for signaling and 10 pin flap cable for USB functions It is not hot swappable Control panels from previous server generations including SR2600 and SR1625 systems are not compatible with the SR2625 system AF002774 Figure 38 Standard Control Panel Assembly Module 7 1 Control Panel Buttons The standard control panel assembly houses several system control buttons
35. revolution for the 80 mm fan Four pulses per revolution for the 60 mm fan Detection if fan is installed in system LED in fan LED Anode Reserved unused by the redundant fan The system fans are hot pluggable and do not have any cable connections They mate directly to the fan module The system fan module plugs into headers on the midplane board as shown in the following figure S ra A FLL Qs EM 3 a EN E x BRR P7 SY W A lt Geer SS AF002994 Figure 18 Redundant Fan Header Assignments on Midplane 34 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Cooling Subsystem Table 25 Redundant Fan Header Assignment Fan ID Midplane Fan Header Name Fan 1 CPU1 Cooling FAN_1 Fan 2 CPU1 Cooling FAN_2 Fan 3 CPU2 Cooling FAN_3 Fan 4 CPU2 Cooling FAN_4 Fan 5 PCI Cooling FAN_5 Fan 6 PCI Cooling FAN_6 The system fan module is designed for ease of use and supports several management features that can be utilized by the Integrated Baseboard Management Controller The fan module houses two different fan sizes System fans 1 2 3 and 4 use an 80 mm fan System fans 5 and 6 use a 60 mm fan Each fan is designed for tool less insertion to or removal from the fan module and can be hot swapped in the event of failure Each fan within the module is equipped with a failure L
36. supply must operate within all specified limits over the input voltage range shown in the following table Table 15 AC Input Rating L eer e eet Aa Parameter Minimum Rated Maximum VAC VAC Current AC Current Line Voltage 85 VAC 4 75 VAC Frequency Im soon ere i sd Notes 1 Maximum input current at low input voltage range is measured at 90 VAC at maximum load 2 Maximum input current at high input voltage range is measured at 180 VAC at maximum load 3 This is not to be used for determining agency input current markings 4 Maximum rated input current is measured at 100 VAC and 200 VAC Harmonic distortion of up to 10 of the rated AC input voltage must not cause the power supply to go out of specified limits The power supply powers off at or below 75 VAC 5 VAC The power supply starts up at or above 85 VAC 4 VAC Application of an input voltage below 85 VAC does not cause damage to the power supply or blow a fuse Revision 1 2 25 Intel order number E46130 005 Power Subsystem Intel Server System SR2625UR TPS 3 8 3 AC Line Dropout Holdup An AC line dropout is defined to be when the AC input drops to 0 VAC at any phase of the AC line for any length of time During an AC dropout of one cycle or less the power supply must meet dynamic voltage regulation requirements over the rated load If the AC dropout lasts longer than one cycle the power supply should recover and meet all turn on requirement
37. 0 Intel 82575 PHYs with Intel UO Acceleration Technology Revision 1 2 3 Intel order number E46130 005 Product Overview Intel Server System SR2625UR TPS Feature Description Expansion Capabilities The following riser card options are available Three full height PCI Express slots passive Two full height PCI X slots with an on board PXH bridge chip and three PCI Express slots Five full height PCI Express slots Hard Drive Options Eight 2 5 inch hot swap SATA SAS hard drives Flex bay for or two additional fixed 2 5 inch hard drives or a 3 5 inch tape drive Peripherals Slimline bay for slimline SATA optical drive PCI riser card bracket Control Panel Standard control panel Intel Local Control Panel LEDs and displays With standard control panel NIC1 Activity NIC2 Activity Power Sleep System Status System Identification Hard Drive Activity Intel Light Guided diagnostics Fan Fault DIMM Fault CPU Fault 5V STBY System Status System Identification POST Code Diagnostics Power Supply Up to two 750 W power supply modules Security Trusted Platform Module Fans Intel Server System SR2625URBRP Non redundant fan option containing three system fans Two non redundant fans in power supply Intel Server System SR2625URLX SR2625URLXT Redundant fan option containing six system fans Two non r
38. 05 Regulatory and Certification Information Intel Server System SR2625UR TPS 11 1 2 11 1 3 Product EMC Compliance Class A Compliance FCC ICES 003 Emissions USA Canada Verification CISPR 22 Emissions International EN55022 Emissions Europe EN55024 Immunity Europe EN61000 3 2 Harmonics Europe EN61000 3 3 Voltage Flicker Europe CE EMC Directive 89 336 EEC Europe VCCI Emissions Japan AS NZS 3548 Emissions Australia New Zealand BSMI CNS13438 Emissions Taiwan GOST R 29216 91 Emissions Russia GOST R 50628 95 Immunity Russia Belarus Certification Belarus Ukraine Certification Ukraine KCC Certification EMI Korea GB 9254 CNCA Certification China GB 17625 Harmonics CNCA Certification China Product Ecology Compliance Intel has a system in place to restrict the use of banned substances in accordance with world wide regulatory requirements A Material Declaration Data Sheet is available for Intel products For more reference on material restrictions and compliance you can view Intel s Environmental Product Content Specification at http supplier intel com ehs environmental htm 92 Europe European Directive 2002 95 EC Restriction of Hazardous Substances ROHS Threshold limits and banned substances are noted below Quantity limit of 0 1 by mass 1000 PPM for Lead Mercury Hexavalent Chromium Polybrominated Biphenyls Diphenyl Ethers PBB PBDE Quantity limit o
39. 130 005 Intel Server System SR2625UR TPS Regulatory and Certification Information Regulatory Compliance Country Marking Battery Perchlorate California Perchlorate Material Special handling may apply See Warning Information www dtsc ca gov hazardouswaste perchlorate This notice is required by California Code of Regulations Title 22 Division 4 5 and Chapter 33 Best Management Practices for Perchlorate Materials This product may include a battery which contains Perchlorate material Safety Multiple Power Cord Marking Sasa This unit has more than one power supply cord To reduce the risk of electrical shock disconnect 2 two power supply cords before servicing Simplified Chinese HE AA D5R HIJN A Di A gt gt ATA 15z HIMET 2 SHAJA WEE Traditional Chinese ES Aah LIBS re o A TENETJA ENE 2 RE ARE gt German Dieses Ger te hat mehr als ein Stromkabel Um eine Gefahr des elektrischen Schlages zu verringern trennen sie beide 2 Stromkabeln bevor Instandhaltung Nordic Countries Connection to WARNING Proper Ground Apparaten skall anslutas till jordat uttag n r den ansluts till Outlet ett n tverk Laite on liitett v suojamaadoituskoskettimilla varustettuun pistorasiaan Connect only to a properly earth grounded outlet O 11 3 Rack Mount Installation Guidelines Anchor the equipment rack The equipment rack must be anchored to an unmovable support to prevent it from
40. 7 Intel order number E46130 005 PCI Riser Cards and Assembly Intel Server System SR2625UR TPS GROUND PAD ON SECONDARY SIDE NO COMPONENT ON SECONDARY SIDE AX COMPONENT HEIGHT ON SECONDARY SIDE IS 3 80NM 58 15 2 3131 53 75 2 116 1 369 MS A 63 11 3630 MAA AAA 0 00 0 000 Ca COMPONENT ON SECONDARY SIDE 0 00 0 000 123 91 4 879 134 67 5 302 147 84 5 8211 2x 42 85 1 687 2x 50 65 1 994 a N Figure 51 2U Butterfly PCI Express Active Riser Secondary Side 88 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Environmental Specifications 10 Environmental Specifications 10 1 System Level Environmental Limits The following table defines the system level operating and non operating environmental limits Table 56 System Environmental Limits Summary Non Operating 40 C to 70 C Temperature Acoustic noise Sound power 7 0 BA in an idle state at typical office ambient temperature 23 2 degrees C Trapezoidal 25 g velocity change 136 inches second 240 lbs to lt 80 lbs 15 KV except I O port 8 KV per Intel Environmental test specification System Cooling 2550 BTU hour Requirement in BTU Hr 10 2 Serviceability and Availability The system is designed to be serviced by qualified technical personnel only The desired Mean Time To Repair MTTR of the system is 30 minutes inc
41. Bi kk kek kk kk 75 Table 50 Control Panel LED Func Sernac ari 77 Table 51 SSI Power LED Operation LE kk kk kek kek kk kk K k kk KK KK KAK KK KAK KH 78 Table 52 Control Panel LED Operation E LEE atea 78 Table 53 50 pin Control Panel ConnectOrf li kk kk kk kk K KK kK KK KK 80 Table 54 Internal USB Header i Eke kk k kek kK kK nn nro k KK kk KK KA KK 81 Table 55 Riser e ee LEE 84 Table 56 System Environmental Limits SUMMALY oocoonccccccnononcncnonanncncnonnnancn cnn o nc kk kk kk 89 Table 57 Time Estimate for System Maintenance Procedures ii n 89 Table 58 POST Progress Code LED Example AAA 102 Table 59 Diagnostic LED POST Code Decoder AAA 103 Table 60 POST Error Messages and Handling kk kek 107 Table 61 POST Error Beep Codes ni dto td 110 Table 62 Integrated BMC Beep Codes AAA 111 x Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS List of Tables lt This page intentionally left blank gt Revision 1 2 xi Intel order number E46130 005 Intel Server System SR2625UR TPS Introduction 1 Introduction This Technical Product Specification TPS provides system specific information detailing the features functionality and high level architecture of the Intel Server System SR2625UR The Intel Server Board S5520UR S5520URT Technical Product Specification should also be refe
42. C410 enclosure management controller o External non volatile Flash ROM o Four fC interfaces o Compliance with SCSI Accessed Fault Tolerant Enclosures SAF TE specification o Compliance with Intelligent Platform Management Interface IPMI Eight 2 5 inch compatible hot swap hard drive connectors Power for an optional tape drive or two additional 2 5 inch SAS SATA hard drives Hard Drive Status and Fault LEDs for each hard drive connector Card edge connectors for most interconnects including o Midplane o Control Panel o Slimline SATA Optical Drive Temperature Sensor FRU EEPROM One 2x4 pin Power Connector 6 5 1 SAS SATA Backplane Layout The hot swap backplane installs on the back side of the hot swap drive bay inside the system Alignment features on the system and backplane assembly make for easy tool less installation For instructions on installing and removing the backplane see the Intel Server System SR2600UR SR2625UR Service Guide The following diagram shows the layout of components and connectors found on the board AF002788 A 13 pin SATA Optical Drive Connector B SATA Optical Drive Connector 62 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Peripheral and Hard Drive Subsystem Figure 35 Hot swap SAS SATA Backplane Front Side View Revision 1 2 63 Intel order number E46130 005 Peripheral and Hard Drive Subsyst
43. Control Panel 2 8 Rack and Cabinet Mounting Options The system is designed to support 19 inches wide by up to 30 inches deep server cabinets The system supports three rack mount options A fixed mount relay rack cabinet mount kit Product Order Code AXXBRACKETS which can be configured to mount the system into either a 2 post rack or 4 post cabinet A tool less full extracting slide rail kit Product Order Code AXXHERAIL2 designed to support an optional cable management arm Product Order Code AXXRACKCARM2 A basic slide rail kit Product Order Code AXXBASRAIL13 designed to mount the system into a standard 19 inches by up to 30 inches deep ElA 310D compatible server cabinet 2 9 Trusted Platform Module TPM Supported only on SR2625URLXT 2 9 1 Overview Trusted Platform Module TPM is a hardware based security device that addresses the growing concern on boot process integrity and offers better data protection TPM protects the system start up process by ensuring it is tamper free before releasing system control to the operating system A TPM device provides secured storage to store data such as security keys and passwords In addition a TPM device has encryption and hash functions The Intel Server System SR2625URLXT implements TPM as per TPM PC Client specifications revision 1 2 by the Trusted Computing Group TCG A TPM device is affixed to the motherboard of the server and is secured from external sof
44. ED In a fan fails server management illuminates the fault LED on the failing fan Each fan within the module is capable of supporting multiple speeds If the external ambient temperature of the system exceeds the value programmed into the thermal sensor data record SDR the Integrated BMC firmware increases the speed for all the fans within the fan module Each fan is responsible for cooling a specific zone of the system If the components in the zone begin to exceed a safe operating temperature as programmed by the SDR the Integrated BMC firmware increases the speed for the fans tied to that zone Each fan connector within the module supplies a tachometer signal that allows the Integrated BMC to monitor the status of each fan If one of the fans fails the remaining fans increase their rotation and attempt to maintain the thermal requirements of the system 4 3 Airflow Support To control airflow within the system the system uses an air baffle and a CPU air duct to isolate and direct airflow to three critical zones the power supply zone the full height PCI riser zone and the CPU memory low profile PCI riser zone 4 3 1 Power Supply Zone An air baffle is used to isolate the airflow of the main system board zones from the zone directly in front of the power supply As the power supply fans pull pre heated air through the power supply from inside the system the zone in front of it must remain as cool as possible by drawing air f
45. EE 112 Reference DOGUm S iia ad 114 vv JV Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS List of Figures List of Figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Figure 19 Figure 20 Figure 21 Figure 22 Figure 23 Figure 24 Figure 25 Figure 26 Figure 27 Figure 28 Figure 29 Figure 30 Figure 31 Figure 32 Top Down View Passive System SKU SR2625URBRP Ghown 7 Major System Components eiii elle 8 Front Panel Feature OVerview AEN 9 Intel Server Board SPPZOOUR eker keke keke keke ke keke kek k e A 10 Intel Server Board S5520UR Component ii kk kek keke 11 Back Panel Ee EE 12 Intel Light Guided Diagnostic LEDs Server Board 13 Optional Front Bez cid till eolica 14 Front Bezel Supporting Standard Control Panel 14 Front Bezel Supporting Intel Local Control Panel 15 Setup Utility TPM Configuration Screen ooococccnnnonccccnononnccnnanannnncnnanennnnnnanccnnnnnnos 17 Mechanical Drawing for Power Supply Module 19 Mechanical Drawing for Power Distribution Module AAA 20 Ree Blair 21 Non redundant Fan Module ias 30 Non redundant Fan Header Assignments on MidplaN AA 32 Fan Module Assembly 33 Redundant Fan Header Assignments on Midplane AAA 34 GPU Ai
46. Each module has a simple retention mechanism to hold the power module in place once it is inserted This mechanism withstands the specified platform mechanical shock and vibration requirements The tab on the retention mechanism is colored green to indicate it is a hot swap touch point The latch mechanism is designed to prevent insertion or removal of the module when the power cord is plugged in This aids the hot swapping procedure 3 4 Hot swap Support Hot swapping a power supply module is the process of extracting and re inserting a power supply module from an operating power system During this process the output voltages remain within specified limits Up to two power supply modules may be on a single AC line The power supply module can be hot swapped using the following procedure Extraction To remove the power supply unplug the power cord first and then remove the power module This can be done in standby mode or power on mode Insertion Insert the module first and then plug in the power cord If the system is powered off the system and the power supply will power on into standby mode or power on mode Revision 1 2 21 Intel order number E46130 005 Power Subsystem Intel Server System SR2625UR TPS 3 5 Airflow Each power supply module incorporates two non redundant 40 mm fans for self cooling and partial system cooling The fans provide at least 10 CFM airflow through the power supply when installed in the system and oper
47. FCC Marking Class A USA This device complies with Part 15 ofthe FCC Rules Operation of this device is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Manufactured by Intel Corporation EMC Marking Class A Canada CANADA ICES 003 CLASS A CANADA NMB 003 CLASSE A Revision 1 2 93 Intel order number E46130 005 Regulatory and Certification Information 94 Intel Server System SR2625UR TPS Regulatory Compliance VCCI Marking Class A BSMI Certification Number amp Class A Warning GOST R Marking KCC Mark Korean Communications Comission China Compulsory Certification Mark Belarus Safety Compliance Mark Waste of Electronic and Electrical Equipment Recycling Mark China Restriction of Hazardous Substance Environmental Friendly Use Period Mark China Recycling Mark Recycling Marks Country Japan Taiwan Russia Korea China Belarus Europe China China International Marking TMB 2 FA A TARR He CT OOD iS IE rr MHS 2 EKRAN EE ED ze BU 9 ZC n ETA C oc E d LEKT E ECKE R TL Z Ant E VCCLA EREHE da a AEREA A TETERA ART gt ERAS ESE SG lt al gt Ba LE y Corrugated Recycles Enterprise Platforms and Services Division Intel order number E46
48. Intel QuickPath Halt The BIOS detects the error condition and responds as follows Interconnect speeds not Logs the error into the system event log SEL ZENS Alerts the Integrated BMC of the configuration error with an IPMI command Does not disable the processor Displays 0195 Processor Front Side Bus speed mismatch detected message in the error manager Halts the system 6 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Product Overview 2 2 System Overview Figure 1 Top Down View Passive System SKU SR2625URBRP Shown 2 3 System Dimensions Table 3 System Dimensions SR2625 Supporting 2 5 in Drives Revision 1 2 7 Intel order number E46130 005 Product Overview Intel Server System SR2625UR TPS 2 4 System Components AF002781 Rack Handles H System Fan Assembly Air Baffles l Standard Control Panel Power Distribution Module Flex Bay Two additional 2 5 inch HDDs or Tape Optional Power Supply Modules Slimline Optical Drive Bay Riser Card Assembly CPU Air Duct G System Memory Note SAS SATA Backplane not shown Hard Drive Bays mmoj O 0 gt Z lt S Front Bezel Optional Figure 2 Major System Components 8 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Product Overview 2 5 Hard Drive and Per
49. Intel Server System SR2625UR Technical Product Specification Intel order number E46130 005 Revision 1 2 January 2010 inside Enterprise Platforms and Services Division Revision History Intel Server System SR2625UR TPS Revision History March 2009 Initial release October 2009 Updated section 7 3 Control Panel Connectors January 2010 1 2 Added security feature for SR2625URLXT Update Section 2 6 NIC Connectors Added Section 2 9 Trusted Platform Module Updated Section 6 4 2 Intel IT IR RAID Disclaimers Information in this document is provided in connection with Intel products No license express or implied by estoppel or otherwise to any intellectual property rights is granted by this document Except as provided in Intel s Terms and Conditions of Sale for such products Intel assumes no liability whatsoever and Intel disclaims any express or implied warranty relating to sale and or use of Intel products including liability or warranties relating to fitness for a particular purpose merchantability or infringement of any patent copyright or other intellectual property right Intel products are not intended for use in medical life saving or life sustaining applications Intel may make changes to specifications and product descriptions at any time without notice Designers must not rely on the absence or characteristics of any features or instructions marked reserved or undefined Intel rese
50. Main Power Connector Power Subsystem Intel order number E46130 005 Pin Signals 18 AWG Color Pin Signal 18 AWG Colors 1 3 3 VDC Orange 13 3 3 VDC Orange 2 3 3 VDC Orange a e ee Blue 3 COM GND Black 15 COM Black 4 5 VDC Red 16 PS ONS Green 5VRS Red 24 AWG 17 COM Black 5 COM Black 18 COM Black 6 5 VDC Red 19 COM Black 7 COM Black 20 Reserved 5V in ATX N C 8 PWR OK Gray 21 5 VDC Red 9 5 VSB Purple 22 5 VDC Red 10 12 V3 Yellow Blue 23 5 VDC Red 11 12 V3 Yellow Blue 24 COM Black 12 3 3 VDC Orange 3 7 2 P2 Processor Power Connector Connector housing 8 pin Molex 39 01 2085 or equivalent Contact Molex 45750 1112 or equivalent Table 10 P2 Processor Power Connector Pin Signal 16 AWG Colors Pin Signal 16 AWG Colors 1 COM Black 5 12 V1 Yellow 2 COM Black 6 12 V1 Yellow 3 COM Black 7 12 V2 Yellow Black 4 COM Black 8 12 V2 Yellow Black Revision 1 2 23 Power Subsystem Intel Server System SR2625UR TPS 3 7 3 P3 Power Signal Connector Connector housing 5 pin Molex 50 57 9705 or equivalent Contact Molex 16 02 0087 or equivalent Table 11 P3 Power Signal Connector PIN Signal 24 AWG Colors 1 PC Clock SCL White Green 2 C Data SDL White Yellow 3 SMBAlert White 4 ReturnS White Black 5 3 3RS White Orange 3 7 4 P4 Backplane Power Connector Connector ho
51. a TPM enabled operating system to verify system boot integrity Produces EFI and legacy interfaces to a TPM enabled operating system for using TPM Produces ACPI TPM device and methods to allow a TPM enabled operating system to send TPM administrative command requests to the BIOS Verifies operator physical presence Confirms and executes operating system TPM administrative command requests Provides BIOS Setup options to change TPM security states and to clear TPM ownership For additional details refer to the TCG PC Client Specific Implementation Specification the TCG PC Client Specific Physical Presence Interface Specification and the Microsoft BitLocker Requirement documents 2 9 2 1 Physical Presence Administrative operations to the TPM require TPM ownership or physical presence indication by the operator to confirm the execution of administrative operations The BIOS implements the operator presence indication by verifying the setup Administrator password A TPM administrative sequence invoked from the operating system proceeds as follows 1 User makes a TPM administrative request through the operating system s security software 2 The operating system requests the BIOS to execute the TPM administrative command through TPM ACPI methods and then resets the system 3 The BIOS verifies the physical presence and confirms the command with the operator 4 The BIOS executes TPM administrative command s inhibits BIOS Setu
52. aders on the midplane board as shown in the following figure A AF003109 Figure 16 Non redundant Fan Header Assignments on Midplane Table 22 Non redundant Fan Header Assignment Fan ID Midplane Fan Header Name Fan 1 CPU1 cooling FAN_2 Fan 2 CPU2 cooling FAN A Fan 3 PCI cooling FAN_5 32 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Cooling Subsystem 4 2 Redundant System Fan Module AF003108 Figure 17 Fan Module Assembly Table 23 Redundant Cooling Zones O eee Description of Greatest Cooling Influence Zone System Fan 1 amp 2 CPU2 Primary cooling for CPU 2 and Memory 1 System Fan 2 amp 3 CPU1 Primary cooling for hard drives 4 and 5 CPU 1 and memory 2 ee height PCI cards and Intel 5520 Chipset IOH Primary cooling for hard drives O and 1 and the fans per module Supply power supply module s Each 10 pin fan connector provides power and ground PWM control tachometer output a fan present detection signal and a fault LED signal allowing it to be monitored independently by server management software The following table provides the pin out and description for the connectors on each fan Revision 1 2 33 Intel order number E46130 005 Cooling Subsystem Intel Server System SR2625UR TPS Table 24 Redundant Fan Connector Pin Assingment Tachometer A Fan RPM sensor output Two pulses per
53. an and an 80 mm variable speed fan The system uses a variable fan speed control engine to provide adequate cooling for the system at various ambient temperature conditions under various server workloads and with the least amount of acoustic noise possible To minimize acoustics the fans operate at the lowest speed for any given condition The Integrated Baseboard Management Controller Integrated BMC on the Intel Server Board S5520UR is used for the variable fan speed control function The Integrated BMC monitors selective component temperatures the ambient temperature and each fan s RPM to determine the necessary airflow The Integrated BMC sets the fan speeds to the appropriate RPM to maintain proper cooling The Integrated BMC also logs errors into the System Event Log SEL when temperature sensors exceed their safe operating ranges or if any of the fans fail to operate at safe airflow speeds If a fan fails the Integrated BMC boosts the remaining fans to compensate for the lost airflow A system with redundant fans can continue to operate in this degraded condition while the non redundant system may not If the cooling is not sufficient under a failed fan condition the system eventually shuts down to protect its primary components from thermal damage Additionally this fan boost causes additional vibration in this system Some hard drives are very susceptible to vibration For additional details see Section 4 6 Revision 1 2 29
54. anannonnnnnnnonnnnnnno nono 45 Revision 2 Intel order number E46130 005 List of Tables Intel Server System SR2625UR TPS Table 33 2x4 SAS SATA Backplane Power Connector Pin out J8L1 48 Table 34 1x7 Tape Drive Option Power Connector Pin out J2N2 uE E 49 Table 35 Slimline Optical Drive Slot Connector UCI 49 Table 36 1 C Connector J2M2 located on the back side of the backplanel 49 Table 37 PCI Express X4 Slot Connector from Midplane J4N1 50 Table 38 PCI Express X4 Slot Connector from Midplane J6N1 51 Table 39 Control Panel Connector J2 N1 E apar aaa 52 Table 40 SAS SATA Hard Drive Connector Pin outs J1B1 J2B1 J1B2 J2B2 J3B1 J4B1 JS B2 E EE 53 Table 41 Hard Drive LED Function Definitions u EEE EKA 66 Table 42 Hard Drive Activity LED Functionality u Ek kk kk 66 Table 43 Control Button and Intrusion Switch FUNCTIONS E EE EEE kk 69 Table 44 Control Panel LED FURnCt OIS E EEEE clase lap Ek kk kk kK KK k kK KK kk KH 70 Table 45 SSI Power LED Operation vicioso ke kek ke ke kk KK xe kK SEENEN 71 Table 46 Control Panel LED Operation EE 71 Table 47 External USB Connectors J21 isaac Eege kk kk kk kK kk kk 73 Table 48 Video Connector J1D1 uE dada 73 Table 49 50 pin Control Panel Connector LID
55. applicable Green Solidon Ok System booted and ready Ok Degraded System degraded Including but not limited to Unable to use all of the installed memory more than one DIMM installed Correctable errors over a threshold of 10 and migrating to a spare DIMM memory sparing This indicates that the user no longer has spare DIMMs indicating a redundancy lost condition Corresponding DIMM LED should light up In a mirrored configuration when memory mirroring takes place and system loses memory redundancy This is not covered by the second bullet above Redundancy loss such as power supply or fan This does not apply to non redundant subsystems PCI Express link errors CPU failure disabled if there are two processors and one of them fails Fan alarm Fan failure Number of operational fans should be more than the minimum number needed to cool the system Non critical threshold crossed temperature and voltage 78 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Intel Local Control Panel Color State Criticality Amber Blink Non critical Non fatal alarm system is likely to fail Including but not limited to Critical voltage threshold crossed VRD hot asserted Minimum number of fans necessary to cool the system are not present or have failed In non sparing and non mirroring mode if the threshold of ten correctable errors is crossed within the wind
56. assive Midplane Board Revision 1 2 39 Intel order number E46130 005 System Board Interconnects Intel Server System SR2625UR TPS The system also supports an active SAS SAS RAID midplane This system board incorporates an LSI LSISAS1078 SAS controller onto the board For information about SAS SAS RAID support see Chapter 6 The following figure shows the location for each connector found on this board K AF002790 Optional RAID Cache Battery Backup Connection Power Connector Mini DIMM Connector Fan 6 Connector Fan 4 Connector Fan 3 Connector Fan 1 Connector Fan 2 Connector RAID Activation Key Connector Backplane Connector Fan 5 Connector mi m lololo gt r x z o Bridge Board Connector Figure 23 Active SAS SAS RAID Midplane Board The following tables define the connector pin outs for both midplane boards Table 26 120 pin Server Board to Midplane Bridge Board Connector Pin out Pin Signal Name Pin Signal Name GND 61 SMB SENSOR 3V3SB_CLK_BUF PE1_ESB_TX_DN3 62 SMB SENSOR 3V3SB_DAT_BUF PE1 ESB TX DP3 6 EM BRIDGE PRSNT N GND 64 G 3 PE_WAKE_N 65 PE1_ESB_RX_DN_C3 66 PET_ESB_AX_DP_C3 PE1 ESB TX DN2 67 GND PE1_ESB_TX_DP2 68 FAN_PRSNT6_N oy A N 9 ND GND 69 GND co 40 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS System Board Interconnects Pin Signal Name Pin Signal Name
57. ating at maximum fan speed The cooling air enters the power module from the PDB side pre heated air from the system 3 6 AC Power Cord Specification Requirements The AC power cord used must meet the specification requirements listed in the following table Table 7 AC Power Cord Specifications Cable Type SJT Wire Size 16 AWG Temperature Rating 105 C Amperage Rating 13A Voltage Rating 125 V 0 05840 004 0 2340 008 0 160 008 dur di H 3 7 Output Cable Harness The power distribution board provides a cable harness providing connectors to the various system boards The harness size connectors and pin outs are shown below Listed or recognized component appliance wiring material AVLV2 CN rated 105 minimum 300 VDC minimum is used for all output wiring Table 8 Power Harness Cable Definitions Length To No of mm Connector Pins SES 95 P1 2x12 Main Power Connector 90 angle 110 P2 2x4 Processor Power Connector 90 angle 100 P3 1x5 Server Board Signal Connector 150 P4 2x4 Backplane Power Connector 220 P5 2x5 Midplane Power Connector 22 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS 3 7 1 P1 Server Board Power Connector Connector housing 24 pin Molex Mini Fit Jr 39 01 2245 or equivalent Contact Molex Mini Fit HCS Female Crimp 44476 or equivalent Table 9 P1
58. cal Control Panel Overview c c cccesessssssssesesesesecscsssssesssesenscecetecscassesensees 76 Seet Deel siy 4425041 a laa 82 2U PCI Express Passive EE 83 2U PCI Express Passive Riser Primary Side EE ee 85 2U PCI Express Passive Riser Secondary Side EE 86 2U Butterfly PCI X PCI Express Active Riser Primary Side E UUU 86 2U Butterfly PCI X PCI Express Active Riser Secondary Gide 87 2U Butterfly PCI Express Active Riser Primary Side ccccconnnonoccccnnnoniccnncnnnnnnos 87 2U Butterfly PCI Express Active Riser Secondary Side o ooooonooocccccccccccccncannnnoos 88 Diagnostic LED Placement Diagram sesionar ars 102 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS List of Tables List of Tables Tabler1 SySstem Fealtre E 3 Table 2 Mixed Processor Configurations cocineta 6 Table 3 System DIMENSIONS saciar did di add ri KAK A KAR kK KAR 7 Table 4 Driv Overvie W5 a xanyk n e ati 9 Table 5 Major Board Components occitano kk kk kK k kK KK KA KK KA kK 12 Table 6 TSetup Utility Security Configuration Screen Fields k 18 Table 7 AC Power Cord Specifications EE 22 Table 8 Power Harness Cable Definitions EE kk kk kk kk 22 Table 9 P1 Main Power Connector units Eed 23 Table 10 P2 Processor Power COMECION cuco 23 Table 11 P3 Ee EIERE 24 Table 12 P4 Back
59. cessible environment The FRUSDR utility must be run to load the proper Sensor Data Records for the server system onto the server board Make sure the latest system software is loaded on the server This includes system BIOS FRUSDR Integrated BMC firmware and hot swap controller firmware The latest system software can be downloaded from http support intel com support motherboards server s5520ur Revision 1 2 101 Intel order number E46130 005 Appendix B POST Code Diagnostic LED Decoder Intel Server System SR2625UR TPS Appendix B POST Code Diagnostic LED Decoder During the system boot process the BIOS executes a number of platform configuration processes each of which is assigned a specific hex POST code number As each configuration routine is started the BIOS displays the POST code to the POST Code Diagnostic LEDs on the back edge of the server board To assist in troubleshooting a system hang during the POST process the Diagnostic LEDs can be used to identify the last POST process that was executed Each POST code is represented by eight amber Diagnostic LEDs The POST codes are divided into two nibbles an upper nibble and a lower nibble The upper nibble bits are represented by Diagnostic LEDs 4 5 6 7 The lower nibble bits are represented by Diagnostics LEDs 0 1 2 and 3 If the bit is set in the upper and lower nibbles the corresponding LED is lit If the bit is clear the corresponding LED is off The Diagn
60. crossed No power good power fault Processor configuration error e g processor stepping mismatch 7 2 3 Drive Activity LED The drive activity LED on the front panel indicates drive activity from the on board hard disk controllers The Intel Server Board S5520UR also provides a header giving access to this LED for add in controllers 7 2 4 System Identification LED The blue system identification LED is used to help identify a system for servicing This is especially useful when the system is installed in a high density rack or cabinet that is populated with several similar systems The blue system ID LED can be illuminated using one of the following mechanisms By pressing the system ID button on the system control panel the ID LED displays a solid blue color until the button is pressed again By issuing the appropriate hex IPMI system identify value the ID LED either blinks blue for 15 seconds and turns off or blinks indefinitely until the appropriate hex IPMI system identify value is issued to turn it off 72 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS 7 3 Control Panel Connectors The control panel has two external I O connectors One USB port One VGA video port The following tables provide the pin outs for each connector Table 47 External USB Connectors J2D1 CI COLI Table 48 Video Connector J1D1 raz A vea reo i le jeo
61. ctors Product Order Code ASR26XXFHLPR Two low profile PCI Express connectors Note All PCI Express add in cards run at x8 speeds independent of population The PCI Express x16 connectors utilize a x8 electrical connection 84 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625U RTPS 9 2 PCI Riser Card Mechanical Drawings 5 5 00 0 197 D8 26 0 325 GROUND PAD ON BOTH SIDES 6 00 0 236 3 50 0 138 2X R2 00 DETAIL A 10 079 SCALE 5 000 SEE DETA 74 55 2 935 68 86 2 711 g 48 54 1 91 NO COMPONENT ON PRIMA 28 22 22 51 17 00 1 65 0 00 1 57 0 062 Ei 61 CIANFER 05010 0201 45 ER Figure 46 Revision 1 2 2X 67 00 2 6381 K 8 2 0 325 NO COMPONENT NO TRACE ep ON SECONDARY SIDE IL 4 170 55 5 7151 3x 2 50 0 098 IDE 193 55 7 620 PCI Riser Cards and Assembly O COMPONENT ON PRIMARY SIDE R1 00 0 039 TYP D Wy e GH ar 66 00 12 5981 1 90 0 075 1 90 0 075 e Ex A a s o onm o owo e gt o PORO S Do N e 2 vn up w e se n wen n e a e o n E o e wn s o n e BM o am Ki Ba e a gt lt gt gt lt Sn m Ze 2U PCI Express Passive Riser Primary Side Intel order number E46130 005 198 64 7 8211 210 00 8 268 22 00 0 866 3X 8 40 0 331 85
62. e Table 29 Midplane to Backplane Card Edge Connector 1 Pin out J7A1 HSBP 1 I F in Signal Name Ai RST PS PWRGD A2 A3 A4 SATA1 RX N A5 SATA1 RX P A6 A7 A8 TT SATA1_TX_P A9 SATA1_TX_N A10 A11 A12 USB2_ESB_OC_N A13 A14 A15 SATA3 RX N A16 SATA3 RX P A17 A18 A19 A20 SATA3 TX P A21 SATA3 TX N A22 A23 A24 SATA5 RX N A25 SATA5 RX P A26 A27 A28 SATA5 TX P A29 SATA5 TX N A30 GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND Pin Signal Name 7 2 B SATAO_TX_P Intel order number E46130 005 System Board Interconnects 43 System Board Interconnects Intel Server System SR2625UR TPS J7A1 HSBP 1 I F Pin Signal Name Pin Signal Name A31 B31 SATALTXN A32 P5V_STBY B32 GND Table 30 Midplane to Backplane Card Edge Connector 2 Pin out A B6 7 8 B9 2 4 S 5 A18 USBO_ESB_DN B18 GND A19 GND B19 USB1_ESB_OC_N A20 LED_NIC1_ACT_N B20 LED_HDD_ACTIVITY_N A22 FM_SIO_TEMP_SENSOR B22 FP_ID_SW_L A23 LED NG UNK N B23 BMC_RST_BTN_N A24 LED_NIC2_ACT_N B24 FP_PWR_BTN_N A16 GND B16 USB1_ESB_DN A17 USBO_ESB_DP B17 GND A25 GND B25 FP NMI BTN_N A26 V_BLUE_CONN_FP B26 FP_PWR_LED_3VSB A21 LED NC UNK N B21 LED HDD DNA 44 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS System Board Interconnects Table 31 Active Midplane SAS RAID Battery Backup Connector
63. ed A disabled TPM device will not execute commands that use TPM functions and TPM security operations will not be available An enabled and deactivated TPM is in the same state as a disabled TPM except setting of TPM ownership is allowed if not present already An enabled and activated TPM executes all commands that use TPM functions and TPM security operations will be available TPM No Operation No Operation No changes to current Administrative Turn On state Control Turn Off Turn On Enables and activates TPM Clear Ownership Turn Off Disables and deactivates TPM Clear Ownership Removes the TPM ownership authentication and returns the TPM to a factory default state Note The BIOS setting returns to No Operation on every boot cycle by default 18 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Power Subsystem 3 Power Subsystem The power subsystem of the system consists of an integrated Power Distribution Module PDM a power module enclosure and support for up to two 750 Watt power supply modules The power subsystem can be configured to support a single module in a 1 0 non redundant configuration or dual modules in a 1 1 redundant power configuration In a 1 1 configuration a single failed power module can be hot swapped with the system running Either configuration supports up to a maximum of 750 Watts of power This chapter provides technical d
64. ed drives use the Server Configurator Tool available at http serverconfigurator intel com default aspx The optical drive is mounted to a tool less assembly latch that allows for easy installation and attachment to the system Once it is inserted into the system the assembly locks into place It is not hot swappable For removal the system must be powered down the system top cover removed and the locking latch disengaged For additional details see the Intel Server System SR2600UR SR2625UR Service Guide 54 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Peripheral and Hard Drive Subsystem AF002777 Figure 28 Slimline Optical Drive Assembly for 2 5 inch drive System The SATA Optical drive plugs directly into the backplane using industry standard 13 pin SATA connector This SATA channel is routed from USB to SATA converter located on the backplane The optical drive is seen as a USB device in the system 6 2 Hard Drive Bays The system supports up to eight hot swap 2 5 inch SAS or SATA hard disk drives Hard drives are mounted to hot swap drive trays for easy insertion to or extraction from the drive bay Two additional fixed mount 2 5 inch drives are supported with an optional drive cage 6 2 1 Hot swap Drive Carriers Each hard drive must be mounted to a hot swap drive carrier making insertion and extraction of the drive from the system very simple Each drive carrie
65. edundant fans in power supply System Management On board ServerEngines LLC Pilot II Controller Integrated Baseboard Management Controller Integrated BMC IPMI 2 0 compliant Integrated Super I O on LPC interface Support for Intel System Management Software 3 1 The Trusted Platform Module is only availabe in SR2625URLXT Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Product Overview 2 1 1 Processor Support The server board supports the following processors One or two Intel Xeon Processors 5500 Series in FC LGA 1366 socket B package with 4 8 GT s 5 86 GT s or 6 4 GT s Intel QuickPath Interconnect Up to 95 W Thermal Design Power TDP processors having higher Thermal Design Power are not supported Previous generations of the Intel Xeon processors are not supported on the server board 2 1 1 1 Processor Population Rules Note Although the server board does support dual processor configurations consisting of different processors that meet the defined criteria below Intel does not perform validation testing of this configuation For optimal system performance in dual processor configurations Intel recommends that identical processors be installed When using a single processor configuration the processor must be installed into the processor socket labeled CPU1 A terminator is not required in the second processor socket when using a
66. el Local Control Panel 8 2 The Intel Local Control Panel module is cabled to matching connectors on the backplane When the pre assembled control panel module is installed into the system cables should be manually connected This section defines the pin out for each connector and header found on Intel Server System SR2625UR TPS Intel Local Control Panel Interconnects the control panel interface board 80 Signals from the backplane are routed to the control panel interface board through matching 50 pin connectors on the backplane and control panel interface board The 50 pin connectors are attached using a small 50 pin flat cable USB signals from the backplane connector are routed to the control panel interface board through matching 10 pin connectors on the backplane and control panel interface board The 10 pin connectors are attached using a small 10 pin round cable A 4 pin IPMI header not used A 4 pin NMI Temp Sensor header The following tables provide the pin outs for each connector Table 53 50 pin Control Panel Connector Pin Signal Name Pin Signal Name 1 V_IO_RED_CONN_FP 26 Ground 2 V_IO GREEN_CONN_FP 27 Ground 3 V_IO BLUE CONN_FP 28 Ground 4 V_IO HSYNC_BUFF_FP 29 Ground 5 V_IO VSYNC_BUFF_FP 30 Ground 6 N C 31 FP_THERM_SENSOR 7 N C 32 N C
67. em Intel Server System SR2625UR TPS AF002789 A 50 pin Control Panel Connector D Power Connector B 10 pin USB Connector for Control Panel E Midplane Connectors C Power Connector for Tape Drive or 2 5 inch fixed drives Figure 36 Hot swap SAS SATA Backplane Back Side View Notes To prevent the backplane from flexing when installing or removing hard drives from the drive bay make sure the midplane is securely fastened and the system top cover is in place Make sure all system boards peripherals and cables are detached from the backplane before removing the backplane from the system Failure to detach components from the backplane before removal may result in component damage 64 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS 6 5 2 Peripheral and Hard Drive Subsystem SAS SATA Backplane Functional Architecture The following figure shows the functional blocks of the SAS SATA backplane SPI_INTERFACE I2C CONN EEPROM GPIO I2C CONN E VSC_3V3_I2C_BUSO GPIO USC 3U3 12C BUST a EEPROM em j RECH LM7S em I2C CONN EEPROM gt LEVEL SHIFT SAS SATA_ HDD CONN
68. enced radio TV technician for help Revision 1 2 97 Intel order number E46130 005 Regulatory and Certification Information Intel Server System SR2625UR TPS Any changes or modifications not expressly approved by the grantee of this device could void the user s authority to operate the equipment The customer is responsible for ensuring compliance of the modified product Only peripherals computer input output devices terminals printers etc that comply with FCC Class A or B limits may be attached to this computer product Operation with noncompliant peripherals is likely to result in interference to radio and TV reception All cables used to connect to peripherals must be shielded and grounded Operation with cables connected to peripherals that are not shielded and grounded may result in interference to radio and TV reception 11 5 2 ICES 003 Canada Cet appareil num rique respecte les limites bruits radio lectriques applicables aux appareils num riques de Classe Aprescrites dans la norme sur le mat riel brouilleur Appareils Num riques NMB 003 dict e par le Ministre Canadian des Communications English translation of the notice above This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Canadian Department of Communications 11 5 3 Europe CE Declaration
69. er number E46130 005 Intel Server System SR2625UR TPS NO COMPONENT ON SECONDARY 0 PCI Riser Cards and Assembly ROUND PAD ON SECONDARY SIDE SIDE AX COMPONENT HEIGHT ON SECONDARY SIDE IS 3 80NM 168i 58 15 12 3131 hoe 53 75 12 116 7001 576 3691 2611 Sp Wun AI Weg 0 00 0 000 123 91 4 679 134 67 5 302 2X 50 65 1 994 Cat n 15 8211 2x 42 85 1 681 Figure 49 2U Butterfly PCI X PCI Express Active Riser Secondary Side D8 26 0 325 GROUND PAD ON BOTH SIDES SIDE 6 00 0 236 8 26 0 325 NO CONPONENT NO TRACE ON SECONDARY SIDE 2x R2 00 2 s DETAIL A 10 079 S SCALE 5 000 lt e lt H o COMPONENT SEE DETAIL A E 2 ON PRIMARY SIDE 10 16 10 4007 A sien 10 0391 TYP 14 55 2 935 AL 68 86 2 1111 loo ISA 5 ox 67 00 12 638 S rs 2X 66 00 2 5981 pm 48 54 1 9111 AE NO COMPONENT ON PRIMARY SIDE 28 22 CII El HIKIN 22 51 0 886 Bien 0 j ee exe p u pos fe 22 00 0 866 17 00 0 569 1 65 0 3011 3X 8 40 10 331 Ke Live II CA REN E Hy hc gt i 1 40 10 055 1 90 0 075 e 1 57 0 062 ou Our 1 90 0 075 0 5010 0201 45 te6 EH on nd mmm Ss Es 8 amp z SHE S S ss 3 2 S55 S 232 8 3 2 323 3 8 2 SS 5 a e EE E S S 332 8 ES 2 182 zs e AN ss e s sass g s PIN H RE o SS 2 SS 5 E r 3 Figure 50 2U Butterfly PCI Express Active Riser Primary Side Revision 1 2 8
70. etails on the operation of the power supply module and power subsystem For additional information refer to the Intel Server System SR2625 AC Power Supply Specification and the Intel Server System SR2625 Power Distribution Module Specification 3 1 Mechanical Overview The following figures display the Power Distribution Module and the Power Supply Module dimensions D 300 0405 Figure 12 Mechanical Drawing for Power Supply Module Revision 1 2 19 Intel order number E46130 005 Power Subsystem Intel Server System SR2625UR TPS Pce edge ENE Figure 13 Mechanical Drawing for Power Distribution Module 20 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Power Subsystem 3 2 Single Power Supply Module Population In single power module configurations server management firmware requires that the power supply module be populated in the top power module slot The non operating slot must have the power supply blank installed AF000023 Figure 14 Power Supply Blank Configuring a single power supply module in the bottom location causes the server management firmware and BIOS to generate a system error during POST and the error is reported to the System Event Log SEL 3 3 Handle and Retention Mechanism Each power supply module includes a handle for module insertion to or removal from the module enclosure
71. f 0 01 by mass 100 PPM for Cadmium California Code of Regulations Title 22 Division 4 5 Chapter 33 Best Management Practices for Perchlorate Materials China Restriction of Hazardous Substances China RoHS WEEE Directive Europe Packaging Directive Europe Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Regulatory and Certification Information 11 1 4 Certifications Registrations Declarations 11 2 NRTL Certification US Canada CE Declaration of Conformity CENELEC Europe FCC ICES 003 Class A Attestation USA Canada VCCI Certification Japan C Tick Declaration of Conformity Australia MED Declaration of Conformity New Zealand BSMI Certification Taiwan GOST R Certification Certification Russia Belarus Certification Certification Belarus KCC Certification Korea IRAM Certification Argentina CNCA CCC Certification China Ecology Declaration International China RoHS Environmental Friendly Use Period Packaging amp Product Recycling Marks Product Regulatory Compliance Markings This Intel Server Chassis product if provided with the following regulatory and safety markings In the event there is no room for a marking s on the chassis the information is provided here in this document Regulatory Compliance Country Marking cULus Listing Marks USA Canada AATERTE W GS Mark Germany D Op G9 WW B C
72. falling over when one or more servers are extended in front of the rack on slides You must also consider the weight of any other device installed in the rack A crush hazard exists should the rack tilt forward which could cause serious injury Safety Stand by power Temperature The temperature in which the server operates when installed in an equipment rack must not go below 5 C 41 F or rise above 40 C 104 F Extreme fluctuations in temperature can cause a variety of problems in your server Ventilation The equipment rack must provide sufficient airflow to the front of the server to maintain proper cooling The rack must also include ventilation sufficient to exhaust a maximum of 1023 BTU s British Thermal Units per hour for the server The rack selected and the ventilation provided must be suitable to the environment in which the server will be used Revision 1 2 95 Intel order number E46130 005 Regulatory and Certification Information Intel Server System SR2625UR TPS If AC power supplies are installed Mains AC power disconnection The AC power cord s is considered the mains disconnect for the server and must be readily accessible when installed If the individual server power cord s will not be readily accessible for discon
73. he system tabs on the back of the assembly should be aligned with slots on the back edge of the system The tabs fit into the slots securing the riser assembly to the system when the top cover is in place For additional information see the Inte Server System SR2600UR SR2625UR Service Guide Figure 45 2U PCI Express Passive Riser Revision 1 2 83 Intel order number E46130 005 PCI Riser Cards and Assembly Intel Server System SR2625UR TPS 9 1 Riser Card Options The Intel Server Board S5520UR has one riser slot capable of supporting riser cards for both 1U and 2U system configurations The riser slot J4E1 implements Intel Adaptive Slot Technology This 280 pin connector is capable of supporting riser cards that meet either the PCI X or PCI Express technology specifications Some risers can support both full height and low profile add in cards by using a butterfly configuration The following table identifies the card configurations and the connector types used Table 55 Riser Card Options Riser Card Option Slot Configuration 2U PCI Express Passive Riser Three full height PCI Express connectors Product Order Code ASR26XXFHR 2U Butterfly PCI Express PCI X Active Two full height PCI X 133 connectors Riser One full height PCI Express connector Product Order Code ASR26XXFHXR Two low profile PCI Express connectors 2U Butterfly PCI Express Active Riser Three full height PCI Express conne
74. hin the module is capable of supporting multiple speeds If the external ambient temperature of the system exceeds the value programmed into the thermal sensor data record SDR the Integrated BMC firmware increases the speed for all the fans within the fan module Each fan is responsible for cooling a specific zone of the system If the components in the zone begin to exceed a safe operating temperature as programmed by the SDR the Integrated BMC firmware increases the speed for the fans tied to that zone Each fan connector within the module supplies a tachometer signal that allows the Integrated BMC to monitor the status of each fan If one of the fans fails the remaining fans increase their rotation and attempt to maintain the thermal requirements of the system Each fan has an associated fault LED on the midplane located next to the fan header If a fan fails system management illuminates the fault LED for the failing fan Table 21 Non redundant Fan Connector Pin Assingment 5 Tachometer A Fan RPM sensor output Two pulse per revolution for the 80 mm fan Four pulses per revolution for the 60 mm fan 6 Return Return path to ground Return path to ground 8 FanPresence Reserved unused by the non redundant fan 9 LED Cathode Loopback signal to pin 10 LED Anode Loopback signal to pin 9 Revision 1 2 31 Intel order number E46130 005 Cooling Subsystem Intel Server System SR2625UR TPS The system fans plug into he
75. hutdown failure fuse blown 1 1 only OCP OVP fan failed Power supply warning events where the power supply continues to 4 Hz Blink Amber operate high temp high power high current slow fan AC present Only 5 VSB on PS Off 1 Hz Blink Green Output ON and OK Green Amber The LED is visible on the rear panel of each installed power supply module 28 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Cooling Subsystem 4 Cooling Subsystem Several components and configuration requirements make up the cooling subsystem of the system These include the system fan module the power supply fans air baffles CPU air duct and drive bay population All are necessary to provide and regulate the airflow and air pressure needed to maintain the system s thermals when operating at or below maximum specified thermal limits For details see Table 56 on page 89 Two system fan assembly options are available for this system The first option is a non redundant three fan solution providing sufficient airflow to maintain internal system thermal requirements when the external ambient temperature remains within specified limits The second option is a redundant fan solution Three parallel sets of fans are arranged in series to provide redundant cooling in the event of a single fan failure Each cooling option utilizes two fan types a 60 mm variable speed f
76. ipheral Bays The system is designed to support several different hard drive and peripheral configurations The system includes a hot swap backplane capable of supporting either SAS or SATA drives The flex bay see letter B in the following figure can optionally be configured to support a 3 5 inch tape drive or two additional fixed 2 5 inch hard drives O0O0000 O00000 O00000 o00000 po poo oooO p000 AF002782 Flex Bay Tape Drive or two fixed 2 5 inch Hard Drives Optional System Control Panel Slimline Optical Drive Bay 2 5 inch Hard Drive Bays 8 oloimlz Figure 3 Front Panel Feature Overview Table 4 Drive Overview Active System Passive System Product Code SR2625URLX SR2625URLXT Product Code SR2625URBRP Slimline SATA Optical Drive Supported Supported SATA Drives Up to eight hot swap 2 5 inch Up to eight hot swap 2 5 inch drives plus two fixed 2 5 inch drives plus two fixed 2 5 inch drives with Flex Bay drives with Flex Bay Up to eight 2 5 inch drives Up to eight 2 5 inch drives Revision 1 2 9 Intel order number E46130 005 Product Overview Intel Server System SR2625UR TPS 2 6 System Board Overview Figure 4 Intel Server B
77. ive cage is installed in the default filler panel Product Order Code ASR2600FIXDRV The kit includes one cage supporting two fixed 2 5 inch drives four vibration isolators power and SAS SATA cables and all required hardware Note These 2 5 inch drives are not hot swappable and must be cabled to either the server board or an add in controller card To install a 3 5 inch tape drive the filler panel is removed and the optional tape drive kit is installed Product Order Codes ASR2500SATAPE or ADRTAPEKIT Both tape drive kits include tape drive mounting tray and necessary cables Note To remove the tape drive tray from the system a spring latch located inside the system on the back right side of the carrier must be released to allow the drive tray to slide free Do not attempt to pull out the drive tray without first releasing the spring latch Doing so may damage the plastic faceplate AF002784 Figure 31 Optional Tape Drive Front View Revision 1 2 57 Intel order number E46130 005 Peripheral and Hard Drive Subsystem Intel Server System SR2625UR TPS 6 4 Midplane Options The midplane is the interconnection between the serve
78. luding diagnosis of the system problem To meet this goal the system enclosure and hardware have been designed to minimize the MTTR The following table defines the maximum time needed by a trained field service technician to perform the listed system maintenance procedures after diagnosing the system and identifying the failed component Table 57 Time Estimate for System Maintenance Procedures Revision 1 2 89 Intel order number E46130 005 Environmental Specifications Intel Server System SR2625UR TPS 10 3 Replacing the Backup Battery The lithium battery on the server board powers the real time clock RTC for up to 10 years in the absence of power When the battery starts to weaken it loses voltage and the server settings stored in CMOS RAM in the RTC e g the date and time may be wrong Contact your customer service representative or dealer for a list of approved devices A WARNING Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by the equipment manufacturer Discard used batteries according to manufacturer s instructions A ADVARSEL Lithiumbatteri Eksplosionsfare ved fejlagtig handtering Udskiftning ma kun ske med batteri af samme fabrikat og type Lev r det brugte batteri tilbage til leverandgren A ADVARSEL Lithiumbatteri Eksplosjonsfare Ved utskifting benyttes kun batteri som anbefalt av apparatfabrikanten Brukt bat
79. n LED CPU 2 Fan Fault LED Status LED Memory 2 Fan Fault LED D Memory 1 Fan Fault LED EN CPU 2 DIMM Fault LEDs CPU 1 Fan Fault LED 5V Standby LED Figure 7 Intel Light Guided Diagnostic LEDs Server Board Revision 1 2 13 Intel order number E46130 005 Product Overview Intel Server System SR2625UR TPS 2 7 Front Bezel Features The optional front bezel is made of molded plastic and uses a snap on design When installed its design allows for maximum airflow to maintain system cooling requirements AF002783 Figure 8 Optional Front Bezel Separate front bezels are available to support systems that use either a standard control panel or the Intel Local Control Panel with LCD support When the standard control panel is used light pipes on the backside of the front bezel allow the system status LEDs to be monitored with the front bezel in the closed position The front bezel lock is provided to prevent unauthorized access to hard drives peripheral devices and the control panel TP02101 Figure 9 Front Bezel Supporting Standard Control Panel When the local control panel is used the control panel module can be adjusted to extend further out from the system face to allow the LCD panel to protrude from the front bezel 14 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Product Overview AF000054 Figure 10 Front Bezel Supporting Intel Local
80. n certificate from local Intel representative Name of Certification Recipient Intel Corporation Date of Manufacturer Refer to date code on product Manufacturer Nation Intel Corporation Refer to country of origin marked on product HU A IN Revision 1 2 99 Intel order number E46130 005 Regulatory and Certification Information Intel Server System SR2625UR TPS 11 6 Regulated Specified Components To maintain the UL listing and compliance to other regulatory certifications and or declarations the following regulated components must be used and conditions adhered to Interchanging or use of other component will void the UL listing and other product certifications and approvals Updated product information for configurations can be found on the Intel Server Builder Web site at the following URL http channel intel com go serverbuilder If you do not have access to Intel s Web address please contact your local Intel representative Server chassis base chassis is provided with power supply and fans UL listed Server board you must use an Intel server board UL recognized Add in boards must have a printed wiring board flammability rating of minimum UL94V 1 Add in boards containing external power connectors and or lithium batteries must be UL recognized or UL listed Any add in board containing modem telecommunication circuitry must be UL listed In addition the modem must have the appropriate telecommunicatio
81. nection then you are responsible for installing an AC power disconnect for the entire rack unit This main disconnect must be readily accessible and it must be labeled as controlling power to the entire rack not just to the server s Grounding the rack installation To avoid the potential for an electrical shock hazard you must include a third wire safety ground conductor with the rack installation If the server power cord is plugged into an AC outlet that is part of the rack then you must provide proper grounding for the rack itself If the server power cord is plugged into a wall AC outlet the safety ground conductor in the power cord provides proper grounding only for the server You must provide additional proper grounding for the rack and other devices installed in it Over current protection The server is designed for an AC line voltage source with up to 20 amperes of over current protection per cord feed If the power system for the equipment rack is installed on a branch circuit with more than 20 amperes of protection you must provide supplemental protection for the server H DC power supplies are installed Connection with a DC Direct Current source should only be performed by trained service personnel The server with DC input is to be installed in a Restricted Access Location in accordance with articles 110 16 110 17 and 110 18 of the National Electric Code ANSI NFPA 70 The DC source must be electrically isolated by double o
82. nnccnnnnn secre renacer 89 10 1 System Level Environmental Limits AEN 89 10 2 Serviceability and Availability cio e 89 10 3 Replacing the Backup Battery ccccceeeeeeseseeeeeeeeeeeeeeeeeseeeeeneeeeeeeeessenseneeeenes 90 11 Regulatory and Certification InformatiON onmmmccccnnnnnnnnnnnseccnnnnecnnnnnnccre nana enn 91 11 1 Product Regulatory Compliance AEN 91 11 1 1 Product Safety Elan ET 91 11 1 2 Product EMC Compliance Class A CGomphance ooooocccccnnnoccccnoccccccnnonancccnanancncnns 92 11 1 3 Product Ecology une LEE 92 11 1 4 Certifications Registrations Declarations EE 93 11 2 Product Regulatory Compliance Markings EE keke 93 11 3 Rack Mount Installation Guidelines nan rrc nana 95 11 4 Power Cord Usage Guidelines siii Re 97 11 5 Electromagnetic Compatibility Notices LEULL Eke n 97 11 5 1 FCC Verification Statement USA msc Ed dedekEEgNAA RE EEe RSC 97 Revisiont2 y Intel order number E46130 005 Table of Contents Intel Server System SR2625UR TPS 11 52 E E 98 11 5 3 Europe CE Declaration of Conformity AAA 98 11 54 VECINA 98 15 97 TN EC RE 99 11 5 6 ROCAS uri 99 11 6 Regulated Specified Components AEN 100 Appendix A Integration and Usage TipS cccoconnnnononicnccicononennnnnanancncnnnnnnnnnnaccnn cnn KAKA KAWA AR WA WAA 101 Appendix B POST Code Diagnostic LED Decoder oooccconnnccccnnnonccnonanccnenonannonennnnanrnennannns 102 Appendix C POST Code Errors 000 107 eil
83. ns safety and EMC approvals for the region in which it is sold Peripheral Storage Devices must be UL recognized or UL listed accessory and TUV or VDE licensed Maximum power rating of any one device or combination of devices cannot exceed manufacturer s specifications Total server configuration is not to exceed the maximum loading conditions of the power supply 100 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Appendix A Integration and Usage Tips Appendix A Integration and Usage Tips This section provides a list of useful information that is unique to the Intel Server System SR2625UR and should be kept in mind while integrating and configuring your Intel Server Board S5520UR Only low profile 1 2 in or 30 48 mm DIMMs can be used in the server system Processor fans are not supported and are not needed in the server system The system fan module and power supply fans provide the necessary cooling needed for the system Using a processor fan in this system may cause Intel System Management Software to incorrectly monitor the system fans The CPU air duct and air baffle must be used to maintain system thermals To maintain system thermals all hard drive bays must be populated with either a hard drive or drive blank System fans are not hot swappable Use of the screw found on the front edge of the top cover is required when the unit is installed in a user ac
84. nsive Disks U T O 112 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Glossary Universal Serial Bus VCCI Voluntary Control Council for Interference VRD Voltage Regulator Down VSB Voltage Standby Revision 1 2 113 Intel order number E46130 005 Reference Documents Intel Server System SR2625UR TPS Reference Documents See the following documents for additional information 114 Intel Server Board S5520UR Technical Product Specification Intel Server System SR2625UR AC Power Supply Module Specification Intel Server Board S5520UR Intel Server System SR2625UR Spares Parts List and Configuration Guide Intel Server System SR2600UR SR2625UR Service Guide Intel S5500 S5520 Server Board Family BIOS External Product Specification Intel Server System Integrated Baseboard Management Controller Core External Product Specification Enterprise Platforms and Services Division Intel order number E46130 005
85. oard S5520UR The following figure shows the board layout of the server board Each connector and major component is identified by a number or letter and a description is given below the figure 10 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Product Overview EE DD CC BB gt HCK ZS ee ND Revision 1 2 LL j F G li A Ao BBSS TEO en O O o __ mt l EE AE H O o j S R QPO N M AF002696 Figure 5 Intel Server Board S5520UR Components 11 Intel order number E46130 005
86. oprocessor used on this server board The final configuration of your end system product may require additional EMC compliance testing For more information please contact your local Intel Representative This is an FCC Class A device Integration of it into a Class B chassis does not result in a Class B device 11 1 Product Regulatory Compliance The server chassis product when correctly integrated per this document complies with the following safety and electromagnetic compatibility EMC regulations Intended Application This product was evaluated as Information Technology Equipment ITE which may be installed in offices schools computer rooms and similar commercial type locations The suitability of this product for other product categories and environments Such as medical industrial telecommunications NEBS residential alarm systems test equipment etc other than an ITE application may require further evaluation 11 1 1 Product Safety Compliance UL60950 CSA 60950 USA Canada EN60950 Europe e IEC60950 International CB Certificate amp Report IEC60950 report to include all country national deviations GS Certification Germany GOST R 50377 92 Certification Russia Belarus Certification Belarus Ukraine Certification Ukraine CE Low Voltage Directive 73 23 EEE Europe IRAM Certification Argentina GB4943 CNCA Certification China Revision 1 2 91 Intel order number E46130 0
87. ostic LED 7 is labeled as MSB and the Diagnostic LED 0 is labeled as LSB A Status LED B ID LED C Diagnostic LEDs Figure 52 Diagnostic LED Placement Diagram In the following example the BIOS sends a value of ACh to the diagnostic LED decoder The LEDs are decoded as follows Table 58 POST Progress Code LED Example Upper Nibble LEDs Lower Nibble LEDs MSB LSB LEDs LED 7 LED 6 LED 5 LED 4 LED 3 LED 2 LED 1 LED 0 8h 4h 2h th 8h 4h 2h 1h Status ON OFF ON OFF ON OFF ON OFF 1 0 1 0 1 1 0 0 Results Ah Ch Upper nibble bits 1010b Ah Lower nibble bits 1100b Ch the two are concatenated as ACh 102 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Appendix B POST Code Diagnostic LED Decoder Table 59 Diagnostic LED POST Code Decoder Diagnostic LED Decoder O On X Off Checkpoint Upper Nibble Lower Nibble Ge MSB LSB 8h 4h 2h th 8h 4h 2h 1h LED 7 6 5 4 3 2 1 0 Multi use code This POST Code is used in different contexts Seen at the start of Memory Reference Code MRC OxF2h o lo lo lo lx lx lo x Start of the very early platform initialization code Very late in POST it is the signal that the OS has switched to virtual memory mode Memory Error Codes Accompanied by a beep code OxE8h No Usable Memory Error No
88. ow Amber Solid on Critical non Fatal alarm system has failed or shut down recoverable Including but not limited to DIMM failure when there is one DIMM present no good memory present Run time memory uncorrectable error in non redundant mode IERR signal asserted Processor 1 missing Temperature e g CPU ThermTrip memory TempHi critical threshold crossed No power good power fault Processor configuration error e g processor stepping mismatch 8 1 3 Drive Activity LED The drive activity LED on the front panel indicates drive activity from the on board hard disk controllers The Intel Server Board S5520UR also provides a header giving access to this LED for add in controllers 8 1 4 System Identification LED The blue system identification LED is used to help identify a system for servicing This is especially useful when the system is installed in a high density rack or cabinet that is populated with several similar systems The blue system ID LED can be illuminated using one of the following mechanisms By pressing the system ID button on the system control panel the ID LED displays a solid blue color until the button is pressed again By issuing the appropriate hex IPMI system identify value the ID LED either blinks blue for 15 seconds and turns off or blinks indefinitely until the appropriate hex IPMI system identify value is issued to turn it off Revision 1 2 79 Intel order number E46130 005 Int
89. owered down normally it is possible that the Power LED is blinking while the system status LED is off This is due to a failure or configuration change that prevents the BIOS from running The current limiting resistors for the power LED the system fault LED and the NIC LEDs are located on the server board 70 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Standard Control Panel 7 2 1 Power Sleep LED Table 45 SSI Power LED Operation Non ACPI System power is off and the BIOS has not initialized the chipset Non ACPI System power is on but the BIOS has not yet initialized the chipset ACPI Mechanical is off and the operating system has not saved any context to the hard disk ACPI lt r Mechanical is off The operating system has saved context to the hard disk S3 S1 ACPI Slow blink DC power is still on The operating system has saved context and gone into a level of low power state ACPI Steady on System and the operating system are up and running Note Blink rate is 1Hz at 50 duty cycle 7 2 2 System Status LED Table 46 Control Panel LED Operation Not ready AC power off Green Blink Degraded System degraded Including but not limited to Unable to use all of the installed memory more than one DIMM installed Correctable errors over a threshold of 10 and migrating to a spare DIMM memory sparing This indicates that the user no longer ha
90. p OxF9h O O O O Jo X X oO Has been called OxFAh o o o o b xo x GE requested the system to reset ResetSystem has been Pre EFI Initialization Module PEIM Recovery 0x30h X X O oO px X X X Crisis recovery has been initiated because of a user request 0x31h X X O O x X X O Crisis recovery has been initiated by software corrupt flash 0x34h X X O O x O xX X Loading crisis recovery capsule 0x35h X X O O px O xX O _ Handing off control to the crisis recovery capsule Ox3Fh X X O O Jo O O Oo Unable to complete crisis recovery capsule 106 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Appendix C POST Code Errors Appendix C POST Code Errors Whenever possible the BIOS outputs the current boot progress codes on the video screen Progress codes are 32 bit quantities plus optional data The 32 bit numbers include class subclass and operation information The class and subclass fields point to the type of hardware that is being initialized The operation field represents the specific initialization activity Based on the data bit availability to display progress codes a progress code can be customized to fit the data width The higher the data bit the higher the granularity of information that can be sent on the progress port The progress codes may be reported by the system BIOS or option ROMs The Response section in the following table is divided into three types No Pa
91. p entry and boots directly to the operating system which requested the TPM command s 2 9 2 2 TPM Security Setup Options The BIOS TPM Setup allows the operator to view the current TPM state and to carry out rudimentary TPM administrative operations Performing TPM administrative options through the BIOS setup requires TPM physical presence verification Using BIOS TPM Setup the operator can turn ON or OFF TPM functionality and clear the TPM ownership contents After the requested TPM BIOS Setup operation is carried out the option reverts to No Operation The BIOS TPM Setup also displays the current state of the TPM whether TPM is enabled or disabled and activated or deactivated Note that while using TPM a TPM enabled operating system or application may change the TPM state independent of the BIOS setup When an operating system modifies the TPM state the BIOS Setup displays the updated TPM state 16 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Product Overview The BIOS Setup TPM Clear option allows the operator to clear the TPM ownership key and allows the operator to take control of the system with TPM You use this option to clear security settings for a newly initialized system or to clear a system for which the TPM ownership security key was lost 2 9 2 3 Security Screen To enter the BIOS Setup press the F2 function key during boot time when the OEM or Intel logo
92. plane Power Connector mamita o ta 24 Table 13 P5 Midplane Power Connector ivi 24 Table 14 Efll le e EE 25 Tabl 15 AC Input Rating EEN 25 Table 16 Over current Protection Limits 240 VA Protection ccecceeeeeeeeeeeeeeeeeeeeeeeeteeeeees 27 Table 17 Over voltage Protection OVP Limite 27 Table 18 Output Power and Current Hatngs ENEE 28 Table 19 LED Indicators ee 28 Table 20 Non redundant Cooling Zones cortina 30 Table 21 Non redundant Fan Connector Pin Assingment oocccccccnocccccccnonoccncnnnnn cnn eke 31 Table 22 Non redundant Fan Header Assignment uiE EEE Ek 32 Table 23 Redundant Cooling Zones accio 33 Table 24 Redundant Fan Connector Pin Assingment cnn cnn nn cnn nnnnnccn 34 Table 25 Redundant Fan Header Assignmerntl Ek kK KK kK KRA 35 Table 26 120 pin Server Board to Midplane Bridge Board Connector Pin out 40 Table 27 Midplane Fan Header Pin outs h ll lllli kk kk k kk k kk kk kk kk KK KA KK KA KK KA 42 Table 28 Midplane Power Connector Pin OUt cccoonnnonoccccncnnnncccnnnnannnonnnnccnnnnnnnnnnonnnnnnnnnnnnnnnnnnnnos 43 Table 29 Midplane to Backplane Card Edge Connector 1 Pin out 43 Table 30 Midplane to Backplane Card Edge Connector 2 Pin OUt 44 Table 31 Active Midplane SAS RAID Battery Backup Connector Pin out 45 Table 32 Passive Midplane SATA SAS Connector Pin OUts cccocooococcccccccccn
93. r Duct with Air EE 36 2 5 inch Drive Carrier with a Blank EEN ke 37 BM ET geed Eed EEN 37 Passive Midplane Board 39 Active SAS SAS RAID Midplane Board 40 Bridge Brain iia da 46 2 5 inch Hot swap SAS SATA Backplane Front Side View 47 2 5 inch Hot swap SAS SATA Backplane Back Side View 48 Flex bay for 3 5 inch Tape Drive or Two 2 5 inch HDDs Front View 54 Slimline Optical Drive Assembly for 2 5 inch drive System U UUUEE U UL j 55 2 5 inch Hard Drive Tray Ale EE 56 Flex BAY sir ee e edd eeg 57 Optional Tape Drive Front View ENEE 57 Passive Midplane Board 58 Revision 1 2 vii Intel order number E46130 005 List of Figures Intel Server System SR2625UR TPS Figure 33 Figure 34 Figure 35 Figure 36 Figure 37 Figure 38 Figure 39 Figure 40 Figure 41 Figure 42 Figure 43 Figure 44 Figure 45 Figure 46 Figure 47 Figure 48 Figure 49 Figure 50 Figure 51 Figure 52 viii Active Midplane with SAS SAS RAID Gupport EEE kk kek kk 59 ew ee 60 Hot swap SAS SATA Backplane Front Side View 63 Hot swap SAS SATA Backplane Back Side View 64 SAS SATA Backplane Functional Block Diagram E E 65 Standard Control Panel Assembly Module 68 Control Panel BUONS cuarteles 69 Control Fame E DS l 3 ilk Neueste cia 70 Standard Control Panel EE 74 Intel Local Control Panel Assembly Module 76 Intel Lo
94. r board and both the hot swap backplane and control panel It is also used to determine which hard drive technology is to be supported Two different midplane options are available for this platform 1 a passive midplane capable of supporting SATA ports from the server board or SAS using ports from an add in card 2 an active SAS SAS RAID midplane that contains an on board SAS controller and requires no cabling This section describes the hard drive interface support of each of the midplane boards 6 4 1 Passive Midplane The passive midplane is used as an interconnect routing drive control signals from either the on board SATA ports of the server board or SAS SATA ports from an add in card to the hot swap backplane The hard drive controller signals are cabled to the midplane which then routes the signals to the hot swap backplane through two edge connectors that plug directly into it AF000047 A Power Connector F Fan 4 Connector B Fan 6 Connector G Fan 3 Connector C Fan 5 Connector H Fan 1 Connector D SAS SATA Connectors l Fan 2 Connector E Bridge Board Connector J Backplane Connector Figure 32 Passive Midplane Board 58 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Peripheral and Hard Drive Subsystem 6 4 2 Active Midplane with SAS SAS RAID Support The active midplane is used to provide SAS SAS RAID support It has an in
95. r has its own dual purpose latching mechanism which is used to both insert extract drives from the system and lock the carrier in place Each drive tray supports a light pipe that provides a drive status indicator The light pipe is located on the backplane and can be viewed from the front of the system Revision 1 2 55 Intel order number E46130 005 Peripheral and Hard Drive Subsystem 56 Intel Server System SR2625UR TPS AF002787 Hard Drive Hard Drive Connector Mounting Screw Side Rail m oo m gt Drive Carrier Figure 29 2 5 inch Hard Drive Tray Assembly Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Peripheral and Hard Drive Subsystem 6 3 Optional Tape Drive or Additional Hard Drives Flex Bay For system configurations that require either a Tape Drive or two additional fixed 2 5 inch drives a multi purpose drive bay is provided By default this drive bay is covered by one face plate The bay is located next to the control panel O0O0000 O00000 O00000 AF002732 Figure 30 Flex Bay To configure two additional fixed 2 5 inch hard drives a dr
96. r reinforced insulation from any hazardous AC source Main DC power disconnect You are responsible for installing a properly rated DC power disconnect for the server system This mains disconnect must be readily accessible and it must be labeled as controlling power to the server The circuit breaker of a centralized DC power system may be used as a disconnect device when easily accessible and should be rated no more than 10 amps Grounding the server To avoid the potential for an electrical shock hazard you must reliably connect an earth grounding conductor to the server The earth grounding conductor must be a minimum 18AWG connected to the earth ground stud s on the rear of the server The safety ground conductor should be connected to the chassis stud with a Listed closed two hole crimp terminal having 5 8 inch pitch The nuts on the chassis earth ground studs should be installed with a 10 in lbs torque The safety ground conductor provides proper grounding only for the server You must provide additional proper grounding for the rack and other devices installed in it Over current protection Over current protection circuit breakers must be provided as part of each host equipment rack and must be incorporated in the field wiring between the DC source and the server The branch circuit protection shall be rated minimum 75Vdc 10 A maximum per feed pair If the DC power system for the equipment rack is installed with more than 10 amperes of p
97. renced to obtain greater detail of functionality and architecture specific to the integrated server board but which are also supported on this server system In addition design level information for specific subsystems can be obtained by ordering the External Product Specifications EPS or External Design Specifications EDS for a given subsystem EPS and EDS documents are not publicly available They are only made available under NDA with Intel and must be ordered through your local Intel representative The Intel Server System SR2625UR may contain design defects or errors known as errata which may cause the product to deviate from published specifications Refer to the Intel Server Board S5520UR S5520URT Intel Server System SR2625UR Specification Update for published errata 1 1 Chapter Outline This document is divided into the following chapters Chapter 1 Introduction Chapter 2 Product Overview Chapter 3 Power Subsystem Chapter 4 Cooling Subsystem Chapter 5 System Board Interconnects Chapter 6 Peripheral and Hard Drive Support Chapter 7 Standard Control Panel Chapter 8 Intel Local Control Panel Chapter 9 PCI Riser Cards and Assembly Chapter 10 Environmental Specifications Chapter 11 Regulatory and Certification Information Appendix A Integration and Usage Tips Appendix B POST Code Diagnostic LED Decoder Appendix C Post Code Errors Glossary Reference Documen
98. resence of a fixed media device hard drive detection etc OxB3h O xX O IX X O O Enabling configuring a fixed media device Removable Media OxB8h O X O O Jo X X X Resetting removable media device OxB9h O X O O lO X X O Disabling removable media device OxBAh o x o o b xo x GE presence of a removable media device CDROM detection OxBCh O xX O O JO O xX X Enabling configuring a removable media device Boot Device Selection BDS OxDO O O X O IX X X X Trying to boot device selection 0 0xD1 O O X O IX X X O ITrying to boot device selection 1 0xD2 O O X O IX X O xX Trying to boot device selection 2 0xD3 OO X O X X 0 O Trying to boot device selection 3 0xD4 O O X O IX O xX X Trying to boot device selection 4 0xD5 O O X O Ix O X O Trying to boot device selection 5 0xD6 O O X O Ix O o X Trying to boot device selection 6 0xD7 O O X O XX O O frying to boot device selection 7 0xD8 OO X O JO X X X Tryingto boot device selection 8 0xD9 OO X O Jo X X O ITrying to boot device selection 9 OxDA OO X o Jo X O X Trying to boot device selection A 0xDB O O X o Jo X O O Trying to boot device selection B 0xDC o O X O Jo O XX Trying to boot device selection C 0xDD o O X O O O X O JITrying to boot device selection D OxDE o O X o Jo o o X ITrying to boot device selection E OxDF OO X O Jo O OD OD Trying to boot device selection F Pre EFI Initialization PEI Core OxE0h O O O X X X X X Started dispatching early initialization modules PEIM OxE1h
99. rom the leftmost drive bays only 4 3 2 Full height Riser Zone The full height riser zone is the area between the power supply assembly and the full height riser card of the riser assembly The airflow through this area is generated by system fan 3 of the fan module in a non redundant fan configuration In a redundant fan configuration the airflow for this zone is provided by system fans 5 and 6 Air is drawn from the drive bay area through the fan and pushed out of the system through ventilation holes on the back side of the system Revision 1 2 35 Intel order number E46130 005 Cooling Subsystem 4 3 3 Intel Server System SR2625UR TPS CPU Memory Low profile PCI Zone The CPU memory low profile PCI zone is the area between the low profile riser card of the riser assembly and the right system wall In a non redundant fan configuration the airflow for this zone is generated by system fans 1 and 2 of the fan module In a redundant fan configuration the airflow for this zone is provided by system fans 1 2 3 and 4 Air is drawn from the drive bay area through the fans directed through the CPU air duct and out through ventilation holes on both the back wall and rear side wall of the system The CPU air duct is used to direct airflow through the processor heatsinks and memory areas for both single and dual processor configurations 36 ef ES ed we gt e gt AAA e E SN Ss e A wS a os a je a di gt J
100. rotection you must provide supplemental protection for the server 96 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Regulatory and Certification Information 11 4 Power Cord Usage Guidelines WARNING Do not attempt to modify or use an AC power cord set that is not the exact type required You must use a power cord set that meets the following criteria Rating In the U S and Canada cords must be UL Underwriters Laboratories Inc Listed CSA Canadian Standards Organization Certified type SJT 18 3 AWG American Wire Gauge Outside of the U S and Canada cords must be flexible harmonized lt HAR gt or VDE Verband Deutscher Electrotechniker German Institute of Electrical Engineers certified cord with 3 x 0 75 mm conductors rated 250 VAC Volts Alternating Current Connector wall outlet end Cords must be terminated in grounding type male plug designed for use in your region The connector must have certification marks showing certification by an agency acceptable in your region and for U S must be Listed and rated 125 of overall current rating of the server Connector server end The connectors that plug into the AC receptacle on the server must be an approved IEC International Electrotechnical Commission 320 sheet C13 type female connector Cord length and flexibility Cords must be less than 4 5 meters 14 76 feet long 11 5 Electromagnetic Compa
101. rved for SMBUS Local Console 0x70h Xx o O O x X X X Resetting the video controller VGA 0x71h X o O oO x X X O Disabling the video controller VGA 0x72h Xx O O O x X O xX Enabling the video controller VGA Remote Console 0x78h x OO O JO X X X Resetting the console controller 0x79h x O O o Jo X X O JDisabling the console controller Ox7Ah X O O O IJO XxX O xX Enabling the console controller Keyboard only USB 0x90h O X X O X X X X Resetting the keyboard 0x91h O Xx X O IX X X O Disabling the keyboard 0x92h O Xx X O IX X O xX Detecting the presence of the keyboard 0x93h O X X O X X O Oo Enabling the keyboard 0x94h O X X O X O X X Clearing keyboard input buffer 0x95h O X X O Jx O X O Instructing keyboard controller to run Self Test PS2 only Mouse only USB 0x98h O X X O JO X X X Resetting the mouse 0x99h O X X O JO X X O Detecting the mouse Ox9Ah O X X O JO X O X Detecting the presence of mouse 0x9Bh O X X O JO X O O Enablingthe mouse Fixed Media OxBOh O xX O O X X X X Resetting fixed media device 0xB1h O xX O O X X X O Disabling fixed media device 104 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Appendix B POST Code Diagnostic LED Decoder Diagnostic LED Decoder O On X Off Checkpoint Upper Nibble Lower Nibble GE MSB LSB 8h 4h 2h 1h 8h 4h 2h 1h LED 7 6 5 4 3 2 1 0 0xB2 h lo X O O IN X ox JDetecting p
102. rves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them The Intel Server System SR2625UR may contain design defects or errors known as errata which may cause the product to deviate from published specifications Current characterized errata are available on request This document and the software described in it are furnished under license and may only be used or copied in accordance with the terms of the license The information in this manual is furnished for informational use only is subject to change without notice and should not be construed as a commitment by Intel Corporation Intel Corporation assumes no responsibility or liability for any errors or inaccuracies that may appear in this document or any software that may be provided in association with this document Except as permitted by such license no part of this document may be reproduced stored in a retrieval system or transmitted in any form or by any means without the express written consent of Intel Corporation Intel Pentium Itanium and Xeon are trademarks or registered trademarks of Intel Corporation Other brands and names may be claimed as the property of others Copyright Intel Corporation 2008 2010 ii Revision 1 2 Intel order number E46130 005 Intel Server System SR2625UR TPS Table of Contents Table of Contents T To TT RE 1 1 1 EE EE 1 1 2 Server Board Use
103. s The power supply must meet the AC dropout requirement over rated AC voltages frequencies and output loading conditions Any dropout of the AC line does not cause damage to the power supply 20 ms minimal when tested under the following conditions Maximum combined load 562 5 W 12 ms minimal when tested under the following conditions Maximum combined load 750 W 3 8 4 AC Line 5 VSB Holdup The 5 VSB output voltage should stay in regulation under its full load static or dynamic during an AC dropout of 70 ms minimal 5 VSB holdup time whether the power supply is in ON or OFF state PSON asserted or de asserted 3 8 5 AC Inrush AC line inrush current should not exceed 40 A peak for up to one quarter of the AC cycle after which the input current should be no more than the specified maximum input current The peak inrush current should be less than the ratings of its critical components including input fuse bulk rectifiers and surge limiting device The power supply must meet the inrush requirements for any rated AC voltage during turn on at any phase of AC voltage during a single cycle AC dropout condition as well as upon recovery after AC dropout of any duration and over the specified temperature range Top It is acceptable that AC line inrush current may reach up to 60 A peak for up to 1 millisecond 3 9 Protection Circuits Protection circuits inside the PDB and the power supply cause the power supply s main 12
104. s The LED illuminates green for activity or amber for a drive fault The green activity LED is driven by the SAS SATA hard disk drive directly The amber fault LED is driven by the VSC410 management controller whenever a fault condition is detected When the drive is used in a RAID configuration the RAID controller has control over the fault LED and it may exhibit different behavior Table 41 Hard Drive LED Function Definitions Status LED The activity LED functionality is controlled directly by the hard drives This causes the LED to function differently between SAS and SATA drives The expected operation is outlined in the following table Table 42 Hard Drive Activity LED Functionality 66 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Peripheral and Hard Drive Subsystem 6 5 2 3 Optional Two 2 5 inch Hard Drives The SR2625 is capable of supporting two additional 2 5 inch non hot swap SAS SATA hard drives with the addition of an optionally installed drive cage and cables The 2 5 inch fixed drive assembly is installed in the default filler panel and consists of a hard drive cage all required mounting hardware and all required cabling 6 6 Enclosure Management Cabling for Passive Midplane When using a rack optimized system with a passive backplane or midplane and an add in RAID card you must install an additional 3 pin cable between the RAID card and the backplane
105. s spare DIMMs specifying a redundancy lost condition The corresponding DIMM LED should light up In a mirrored configuration when memory mirroring takes place and system loses memory redundancy This is not covered by the second bullet above Redundancy loss such as power supply or fan This does not apply to non redundant subsystems PCI Express link errors CPU failure disabled if there are two processors and one of them fails Fan alarm Fan failure Number of operational fans should be more than the minimum number needed to cool the system Non critical threshold crossed temperature and voltage Revision 1 2 71 Intel order number E46130 005 Standard Control Panel Intel Server System SR2625UR TPS Color State _Criticality Amber Blink Non critical Non fatal alarm system is likely to fail Including but not limited to Critical voltage threshold crossed VRD hot asserted Minimum number of fans to cool the system are not present or have failed In non sparing and non mirroring mode if the threshold of ten correctable errors is crossed within the window Amber Solid on Critical non Fatal alarm system has failed or shut down recoverable Including but not limited to DIMM failure when there is one DIMM present and no good memory is present Run time memory uncorrectable error in non redundant mode IERR signal asserted Processor 1 missing Temperature e g CPU ThermTrip memory TempHi critical threshold
106. single processor configuration When two processors are installed the following population rules apply Both processors must be of the same processor family Both processors must have the same front side bus speed Both processors must have the same cache size Processors with different speeds can be mixed in a system given the prior rules are met If this condition is detected all processor speeds are set to the lowest common denominator highest common speed and an error is reported Processor stepping within a common processor family can be mixed as long as it is listed in the processor specification updates published by Intel Corporation The following table describes mixed processor conditions and recommended actions for all Intel server boards and systems that use the Intel 5520 Chipset The errors fall into one of the following two categories Fatal If the system can boot it goes directly to the error manager regardless of whether the Post Error Pause setup option is enabled or disabled Major If the Post Error Pause setup option is enabled system goes directly to the error manager Otherwise the system continues to boot and no prompt is given for the error The error is logged to the error manager Revision 1 2 5 Intel order number E46130 005 Product Overview Intel Server System SR2625UR TPS Table 2 Mixed Processor Configurations Processor family not identical Fatal The BIOS detects the
107. tegrated LSI LSISAS1078 3 Gb s RAID On a Chip ROC device It provides support for up to eight SAS drives in this system By default this midplane option provides software RAID levels 0 1 and 10 and utilizes Intel T IR RAID With the installation of optional RAID enablement devices the midplane can support hardware RAID levels 0 1 5 6 10 50 and 60 The midplane attaches to the hot swap backplane by two card edge connectors which eliminates the need for any hard drive cables The following sub sections describe the board level SAS SAS RAID functionality K AF002790 RAID Battery Backup Unit Connector Power Connector Mini DIMM Connector Fan 6 Connector Fan 4 Connector Fan 3 Connector Fan 1 Connector Fan 2 Connector RAID Activation Key Connector Backplane Connector Fan 5 Connector m m ojoo gt r x o Bridge Board Connector Figure 33 Active Midplane with SAS SAS RAID Support Revision 1 2 59 Intel order number E46130 005 Peripheral and Hard Drive Subsystem Intel Server System SR2625UR TPS 6 4 2 1 Architectural Overview 244 PIN DDR2 667 MHZ MINI DIMM ft GOLD FINGER DDRII SDRAM BATTERY BACKUP SI 3 7 Y emm LSI SAS 1078 667 gt LE X4 P Bi A A 9 ra 9 V V 8 VIDEO SIGNALS 12C FP NIC LED POWER LED
108. tem Board Interconnects Table 38 PCI Express X4 Slot Connector from Midplane J6N1 Pin Signal Name Pin Signal Name Al RST_PWRGD_PS B1 Ground A2 Ground B2 SASO_RX_DN A3 Ground B3 SASO_RX_DP A4 SAS1_RX_DN B4 Ground A5 SAS1_RX_DP B5 Ground A6 Ground B6 SASO_TX_DN A7 Ground B7 SASO_TX_DP A8 SAS1_TX_DP B8 Ground AQ SAS1_TX_DN B9 Ground A10 Ground B10 USB_P3N A11 Ground B11 USB_P3P A12 USB_OC3_N B12 Ground A13 Ground B13 SAS2_RX_DN A14 Ground B14 SAS2_RX_DP A15 SAS3_RX_DN B15 Ground A16 SAS3_RX_DP B16 Not Used A17 Ground B17 SMB_SAS 3V3_SDA A18 Ground B18 Not Used A19 Ground B19 SMB_SAS 3V3_ SCL A20 SAS3_TX_DP B20 Not Used A21 SAS3_RT_DN B21 Ground A22 Ground B22 SAS2_TX_DP A23 Ground B23 SAS2_TX_DN A24 SAS5_RX_DN B24 Ground A25 SAS5_RX_DP B25 Ground A26 Ground B26 SAS4_RX_DN A27 Ground B27 SAS4_RX_DP A28 SAS5_TX_DP B28 Ground A29 SAS5_TX_DN B29 Ground A30 Ground B30 SAS4 TX_DP A31 Ground B31 SAS4_TX_DN A32 P5V_STBY B32 Ground Revision 1 2 51 Intel order number E46130 005 System Board Interconnects Intel Server System SR2625UR TPS Table 39 Control Panel Connector J2N1
109. tem Power Button B LCD Display J System Status LED C LCD Menu Control Button Up K NIC 2 Activity LED D LCD Menu Control Button Down L NIC 1 Activity LED E LCD Menu Control Button Previous Option M Hard Drive Activity LED F LCD Menu Control Button Enter N System Reset Button G IDLED O USB 1 1 Port H Power LED Figure 43 Intel Local Control Panel Overview 76 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS 8 1 LED Functionality Intel Local Control Panel The following table identifies each LED and describes its functionality Table 50 Control Panel LED Functions LED Color State Description NIC1 NIC2 Green On NIC Link Activity Green Blink NIC Activity E Si Green On Legacy power on ACPI SO state ower Sleep TA on standby power Blink Sleep ACPI S1 state Off Off Power off ACPI S4 or S5 state Green On Running normal operation E Blink Degraded ystem Status B GE on standby power Amber On Critical or non recoverable condition Blink Non critical condition Off Off POST system stop We Green Random blink Provides an indicator for disk activity Disk Activity 3 r or Off Off No hard disk activity ae Blue On Identify active via command or button System Identification Off Off No Identification Notes 1 Blink rate is 1 Hz at 50 d
110. teri returneres apparatleverandgren A VARNING Explosionsfara vid felaktigt batteribyte Anv nd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren Kassera anv nt batteri enligt fabrikantens instruktion A VAROITUS Paristo voi r j ht jos se on virheellisesti asennettu Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin H vit k ytetty paristo valmistajan ohjeiden mukaisesti 90 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Regulatory and Certification Information 11 Regulatory and Certification Information A WARNING To ensure regulatory compliance you must adhere to the assembly instructions in this document to ensure and maintain compliance with existing product certifications and approvals Use only the described regulated components specified in this document Use of other products components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region s in which the product is sold To help ensure EMC compliance with your local regional rules and regulations before computer integration make sure that the chassis power supply and other modules have passed EMC testing using a server board with a microprocessor from the same family or higher and operating at the same or higher speed as the micr
111. tibility Notices 11 5 1 FCC Verification Statement USA This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Intel Corporation 5200 N E Elam Young Parkway Hillsboro OR 97124 6497 1 800 628 8686 This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experi
112. tion OVP Each DC DC converter output on the PDB has individual OVP circuits built in and they are locally sensed The PS and PDB shut down and latch off after an over voltage condition occurs This latch is cleared by toggling the PSON signal or by an AC power interruption The over voltage limits are measured at the PDB harness connectors The voltage never exceeds the maximum levels when measured at the power pins of the output harness connector during any single point of fail The voltage never trips any lower than the minimum levels when measured at the power pins of the PDB connector Table 17 Over voltage Protection OVP Limits VSE AVII 3 9 3 Over temperature Protection OTP The power supply is protected against over temperature conditions caused by loss of fan cooling or excessive ambient temperature In an OTP condition the power supply shuts down When the power supply temperature drops to within specified limits the power supply restores power automatically while the 5 VSB remains constantly on The OTP trip level has a minimum of 4 C of ambient temperature hysteresis so that the power supply does not oscillate on and off due to a temperature recovery condition The power supply alerts the system of the OTP condition via the power supply FAIL signal and the PWR LED Revision 1 2 27 Intel order number E46130 005 Power Subsystem Intel Server System SR2625UR TPS 3 10 DC Output Specification 3 10 1 Output Power
113. ts Revision 1 2 1 Intel order number E46130 005 Introduction Intel Server System SR2625UR TPS 1 2 Server Board Use Disclaimer Intel Corporation server boards support add in peripherals and contain a number of high density VLSI and power delivery components that need adequate airflow to cool Intel ensures through its own system development and testing that when Intel server building blocks are used together the fully integrated system will meet the intended thermal requirements of these components It is the responsibility of the system integrator who chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of air flow required for their specific application and environmental conditions Intel Corporation cannot be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non operating limits 2 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Product Overview 2 Product Overview The Intel Server System SR2625 is a 2U server system that is designed to support the Intel Server Board S5520UR S5520URT The server board and the system have features that are designed to support the high density server market The system is integrated with an Intel Server Board S5520UR and is offered in two different system configurations
114. tware attacks and physical theft A pre boot environment such as the BIOS and operating system loader uses the TPM to collect and store unique measurements from multiple factors within the boot process to create a system fingerprint This unique fingerprint remains the same unless the pre boot environment is tampered with Therefore it is used to compare to future measurements to verify the integrity of the boot process After the BIOS complete the measurement of its boot process it hands off control to the operating system loader and in turn to the operating system If the operating system is TPM enabled it compares the BIOS TPM measurements to those of previous boots to make sure the system was not tampered with before continuing the operating system boot process Once the operating system is in operation it optionally uses TPM to provide additional system and data security for example Microsoft Vista supports Bitlocker drive encryption Revision 1 2 15 Intel order number E46130 005 Product Overview Intel Server System SR2625UR TPS 2 9 2 TPM security BIOS The BIOS TPM support conforms to the TPM PC Client Specific Implementation Specification for Conventional BIOS version 1 2 and to the TPM Interface specification version 1 2 The BIOS adheres to the Microsoft Vista BitLocker requirement The role of the BIOS for TPM security includes the following Measures and stores the boot process in the TPM microcontroller to allow
115. um ambient temperature is 25 C e At 300 m 1000 ft the maximum ambient temperature is 35 C 38 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS System Board Interconnects 5 System Board Interconnects System boards within the system include the midplane bridge board hot swap backplane and control panel This chapter describes the interconnect features of each and defines the pin outs for each connector Functional details of each system board are described in later chapters 5 1 Midplane The midplane is designed and used along with that of the bridge board and hot swap backplane to improve cable routing within the system The midplane is the key system board of the system It serves as the primary interface between the server board hot swap backplane and control panel Two midplanes are offered for this system a passive SATA SAS and an active SAS SAS RAID The passive midplane is a simple pass through from the backplane to the SATA connectors on the server board or SAS SATA connectors on an add in card The following figure shows the location for each connector found on the passive midplane board AF000047 A Power Connector F Fan 4 Connector B Fan 6 Connector G Fan 3 Connector C Fan 5 Connector H Fan 1 Connector D SAS SATA Connectors l Fan 2 Connector E Bridge Board Connector J Backplane Connector Figure 22 P
116. use The message is displayed on the screen during POST or in the Error Manager The system continues booting with a degraded state The user may want to replace the erroneous unit The setup POST error Pause setting does not have any effect with this error Pause The message is displayed on the Error Manager screen and an error is logged to the SEL The setup POST error Pause setting determines whether the system pauses to the Error Manager for this type of error where the user can take immediate corrective action or choose to continue booting Halt The message is displayed on the Error Manager screen an error is logged to the SEL and the system cannot boot unless the error is resolved The user needs to replace the faulty part and restart the system The setup POST error Pause setting does not have any effect with this error Table 60 POST Error Messages and Handling 0113 Fixed Media The SAS RAID firmware cannot run properly The user should attempt to Pause reflash the firmware Processor 01 internal error IERR on last boot Processor 02 internal error IERR on last boot Revision 1 2 107 Intel order number E46130 005 Appendix C POST Code Errors Intel Server System SR2625UR TPS 8121 Pause 8130 Pause 8131 Pause 8140 No Pause 8141 No Pause 8160 Pause 8161 Pause 8170 Pause 8171 Pause 8180 No Pause 8181 No Pause 8190 Pause 8198 Pause 8300 Pause 84F2 Pause 84F3 Pause 84F4 Pause 84FF No Pause 8500 Pause 8520
117. using 8 pin Molex Mini Fit Jr PN 39 01 2285 or equivalent Contact Molex Mini Fit HCS Female Crimp 44476 or equivalent Table 12 P4 Backplane Power Connector 18 AWG Colors 12 V4 Yellow Green 12 V4 Yellow Green 5 VSB Purple Orange 3 7 5 P5 Midplane Power Connector Connector housing 10 pin Molex Mini Fit Jr 48025 1000 or equivalent Contact Molex Mini Fit HCS Female Crimp 43030 0007 or equivalent Table 13 P5 Midplane Power Connector Pin Signal 20 AWG Colors Pin Signal 20 AWG Colors 1 COM Black 6 12V3 YellowBlue 2 12 V3 Yellow Blue a3 5V Red 8 12V3 Yellow Blue 4 33V Orange 9 12V3 Yellow Blue 5 Purple 24 Enterprise Platforms and Services Division Intel order number E46130 005 Intel Server System SR2625UR TPS Power Subsystem 3 8 AC Input Requirements The power supply module incorporates universal power input with active power factor correction which reduces line harmonics in accordance with the EN61000 3 2 and JEIDA MITI standards 3 8 1 Efficiency The following table provides the required minimum efficiency level at various loading conditions These are provided at three different load levels 100 50 and 20 Efficiency is tested only at 230 VAC Table 14 Efficiency Loading 100 of Maximum 50 of Maximum 20 of Maximum Recommended Efficiency 85 89 85 3 8 2 AC Input Voltage Specification The power
118. uty cycle 2 The amber status takes precedence over the green status When the amber LED is on or blinking the green LED is off 3 Off when the system is powered off S4 S5 or in a sleep state S1 4 The power LED sleep indication is maintained on standby by the chipset If the system is powered down without going through the BIOS the LED state that is in effect at the time of power off is restored when the system is powered on until the BIOS clears it If the system is not powered down normally it is possible that the Power LED is blinking while the system status LED is off This is due to a failure or configuration change that prevents the BIOS from running The current limiting resistors for the power LED the system fault LED and the NIC LEDs are located on the Intel Server Board S5520UR Revision 1 2 77 Intel order number E46130 005 Intel Local Control Panel Intel Server System SR2625UR TPS 8 1 1 Power Sleep LED Table 51 SSI Power LED Operation Non ACPI System power is off and the BIOS has not initialized the chipset Non ACPI System power is on but the BIOS has not yet initialized the chipset S S4 ACPI hard disk gone into a level of low power state ACPI Steady on System and the operating system are up and running Note Blink rate is 1Hz at 50 duty cycle is off is on to the hard disk E 8 1 2 System Status LED Table 52 Control Panel LED Operation Off Not Not ready AC power off
Download Pdf Manuals
Related Search
Related Contents
CBAT 12V-24V Double battery charger TS-W1ZOOPRO 其文扱説明書 USER`S MANUAL Profibus Option Card For Toshiba VF plus River Record Sheet User Guide ! WARNING - Napoleon Products VPCSA Series / VPCSB Series / VPCSE Series User`s Manual ioi Thermal 5322/5642 Fixed User and Installation Guide Copyright © All rights reserved.