1. No power Burnt fuse or power cord not connected Change fuse or power cord Little water inflow The water tube is blocked Clean the filter check line Mechanical arm moves toward right direction without moving vertical Vertical sensor is damaged Check the sensor if the sensor voltage is gt 0 1V please change If sensor voltage is lt 0 1V it s good Mechanical arm moves up but does not move toward right direction Sensor for the first bath is damaged Change the sensor Mechanical arm does not stop when the machine runs or when pressing left right arrow Alignment sensor is damaged Change the sensor Motion mechanism has loud noise and little power Electrical motor has problem Check the electrical motor and circuit board Mechanical arm moves up and down in a jerky motion The gear for mechanical arm has become damaged Check and change Mechanical arm cannot move side but the electrical motor is good The stainless steel wire for side to side movementis broken Change the stainless steel wire The dryer bath cannot heat The heating pipe or controlled silicon on the temperature controller board is damaged Check and change Words on screen appear blurred The circuit board behind screen is damaged Adjust 103 electric
2. Refer to the Technical Parameters for this information 7 Warranty amp Service Tanner Scientific warrants this product for a period of one year from the date of purchase provided that the customer complies with the rules of this manual Extended warranties are available Contact Tanner Scientific at 888 708 5233 for more information Tanner Scientific will not be responsible for the damage and other problems caused by abuse and misuse of the instrument Service Information If you require any service or parts during the warranty period please contact Tanner Scientific at 888 708 5233 or the sales agent who sold you the unit Prior to calling please have the instrument model and serial number ready Amendment Tanner Scientific reserves the right to change the technical parameters of any model for improving the function of our instruments Quality Guarantee e Tanner Scientific will ensure that every instrument sold has been strictly examined to ensure it meets our stringent quality and technical standards e Service terms are only provided for those who regularly use the instrument and operate the instrument according to its instructions Disposal of Unwanted Instruments Discarding the instrument and its parts should be done according to current laws or regulations Tanner Scientific TN6900 H amp E Slide Stainer 7 8 Troubleshooting H amp E Slide Stainer PROBLEMS CAUSES ELIMINATION
3. User Manual TN6900 H amp E Slide Stainer P47777 T e AN IN E R Read Priorto Operation apt Ds Always keep this manual near the unit scientific TANNER User Manual scientific TN6900 H amp E Slide Stainer 888 708 5233 Info TannerScientific com www TannerScientific com Contents 1 Sale AR O Page 2 2 Technical Parameters 2 3 Installation 3 4 Equipment Overview 3 5 Operation gas e rial 4 6 Cleaning amp Maintenance 7 7 Warranty Service 7 8 Troubleshooting 8 Tanner Scientific TN6900 H amp E Slide Stainer 1 1 Safety e Pay close attention to safety procedures if you are using flammable reagents e If the instrument is not in use for extended periods unplug and cover the unit e Place the instrumenton a stable flat work surface e Ensure the power socket is 3 prong grounding type e Use a dedicated socket for supplying power to avoid power fluctuations e The instrument should not be placed near any flammable or explosive objects e The instrument should only be serviced by factory trained technicians 2 Technical Parameters Processing Time of Each Station 0 secto 59 min The frequency of agitating during container stay can be programmed in a range of 0 6 minutes The duration of dripping after moving out from the container can be programmed in a range of 0 60 seconds Users Total of 10 users including 1 public user without password users 0
4. and our customers Refer to the name plate on the back of the unit for the serial number and manufacturing date of this instrument Distributed by Tanner Scientific 1073 Tallevast Rd Sarasota Florida 34243 888 708 5233 Info TannerScientific com www TannerScientific com TANNER scientific 1073 Tallevast Rd Sarasota Florida 34243 888 708 5233 Info TannerScientific com www TannerScientific com
5. resistance on the circuit board No words on screen The circuit board behind screen or LCD screen isn t functioning Check the voltage ofthe circuit LCD screen cannot work or is not sensitive LCD screen is damaged Change LCD screen 8 Tanner Scientific TN6900 H amp E Slide Stainer TANNER scientific Information The information notes and figures that appear in this user manual represent the present state of knowledge as we comprehend it Due to continuous improvements in technology and manufacturing techniques specifications manufacturing procedures may change For inaccurate statements drawings and technical illustrations in this user manual we exclude liability as far as permissible No liability is accepted for any monetary loss or consequential damage caused by or related to compliance with statements or other information in this user manual Tanner Scientific will update the manual as needed according to the latest technological developments This document is protected under copyright laws Any reproduction of illustrations or text requires prompt documented consent by Tanner Scientific Statements drawings illustrations and other information regarding contents or technical details of the present user manual are not to be considered as warranted characteristics of our products These are determined only by the contract provisions agreed between us
6. and 9 individual users who require a password users 1 9 Total Stations 15 The first bath is the dryer station the second bath is the rinsing station the rest ofthe baths are reagent stations Approximate Volume 350mL Specimen Capacity 24pcs Voltage AC110V Frequency 60Hz Power lt 400VA Dimensions 36 5 x 9 6 x 10 2 Weight 44lbs Fuse F3A 110VAC 2 Tanner Scientific TN6900 H amp E Slide Stainer 3 Installation e Ensure that the outer packaging is not seriously damaged If it is damaged do NOT open Contact Tanner Scientific at 888 708 5233 e Unpack the carton and remove all components including the instruction manual e Take out the instrument and place it on a stable platform e This machine should be stored in a clean and dry indoor place with relative humidity under 80 e Do NOT put the instrument in an explosive or flammable area e The instrument should be installed using only a 3 prong grounding type socket e The instrument should be placed under a vented fume hood e Ensure that there is a water connection and drain near the unit A faucet type connector is provided If using a direct connection just remove end and use secure clamp 4 Equipment Overview HOUSING SCREEN SLIDE BASKET DRYER BATH CLEANING BATH PLASTIC BATH Tanner Scientific TN6900 H amp E Slide Stainer 3 5 Operation Start Up e The instrument must always use the power cord s
7. ation number and then enter a 6 digit password into the second line 8 Re enter the same digits from the first line into the second line to confirm operator code and password Ec pestle Ci 9 If the user does NOT require a password press the Manual key to return back to the main menu 10 Press B to move the basket to left Press to move the basket to right 11 Press A to raise the basket Press W to drop the basket Manual Setting Program Run 12 Press Setting to enter into the setting interface 13 14 Press Faucet symbol to test the cleaning bath 15 Press Y A Y Y to adjust Year Press M A MY to adjust Month Press D A DV to adjust Date Press HA H Y to adjust Hour Press M A M to adjust Minute Press View Record to check Press Dryer symbol to test the dryer system 16 Press HELP to enter into Help menu if needed Manual Setting Program Run View Record Help Cleaning Dryer Tanner Scientific TN6900 H amp E Slide Stainer 5 17 8 9 Press PROGRAM to enter editing interface Press or Y to choose step Press TANK or TANK for bath Press MIN or MIN to set the time for container stay 21 Press SEC or SEC to set seconds for container stay Press STIR or STIR to set agitating time Press DROP or DROP to set drip time Press PROG or PROG for program Press ON key to page up Press UNDER key to page dow
8. n 1 1 A Ma 20 22 23 24 25 my i A lu EIE step tank min PL Tank Min Sec Stir Drop N Tank Min Sec Stir Drop 26 Press RUN key to enter into running interface 27 Press OK key after checking Manual Setting Program Run step tank min On lt Under gt Time total 06 30 28 When the instrument finishes one program the slide basket will stop above the bath for the last step and the machine will sound a buzzing alarm to indicate the program is now finished 29 Remove slide basket and turn off the instrument if finished Or press RUN to process another program Note Cover the cups with the lids once finished with work in order to avoid liquid vaporization Program uj STEP TANK i sec DROP STIR min NEXTSTEP TANK DIP min sec 6 Tanner Scientific TN6900 H amp E Slide Stainer 6 Cleaning amp Maintenance Cleaning e Before cleaning the instrument turn off the main power switch and pull outthe power cord e Acetone and xylene organic solvents should not be used to clean the surface of the instrument Use only common detergent and a soft cloth to keep unit clean e Spilled reagents on the surface or inside the unit can cause damage e Avoid allowing liquid to come in contact with the unit Changing a Fuse e Before replacing a fuse turn off the main power switch and pull out the power cord Replace the fuse with the same model and specifications
9. upplied e The instrument should use the water tube provided This can be connected directly to the main water pipe orto the sink faucet If connecting directly to a water supply a flow regulator is provided e Before connecting to the main power source please make sure that the power switch is in the O OFF position e When connecting the power please insert one end into the instrument and then insert the other end into the wall power plug e Before turning on the instrument please ensure that the water pipe has a good connection e The plastic water drain pipe must be lower than the water outlet in order to avoid water flowing back into the instrument Operation 1 Connect the instrument to the power outlet 2 Connect the water pipes to the stainer 3 Turn on the instrument 4 5 The machine will enter into the menu interface shown below automatically Remove all lids from the plastic baths and make sure the containers are straight and firmly placed into the slots The slide basket will move to the dryer bath and stop above the dryer bath Note Please hold the plastic bath when removing the lids to avoid the bath tipping Manual Setting Program Run 4 Tanner Scientific TN6900 H amp E Slide Stainer Interface After Self Testing 6 Select desired function Then press the middle key to enter into the password setting interface 7 Enter a figure from 1 to 9 in the first line to indicate the user s oper