Home

Owner`s Booklet - Alliance International Co.,Ltd

image

Contents

1. 32 Blood Glucose Meter tcscecsceeseeeeececeeeneneeeeeen 32 Lancing device oa 32 DAMY o ogueen on oceusieuenosseeeseucn 33 Meter Operational Status CheckMg os 33 A 34 Chapter 6 Safety and Disposal cocine 35 Chapter 7 Screen Message and Troubleshooting _ 36 Message Description and Proceeding Solution __ 36 Troubleshooting 40 Standard Kit Contents Supplies and Accessories Standard Kit of 0ARE Blood Glucose Meter 9 oo ete DL S QARE Blood Glucose Meter x 1 CR2032 3V Battery x 1 Lancing Device x 1 Lancet x 10 CODE CARD x 1 Draw In Glucose Test Strip x 10 Wallet x 1 User s Manual x 1 Quick Reference Guide x 1 10 Diary for Self Monitoring x 1 11 Control Solution Normal x 1 Supplies and Accessories Need to be purchased separately Cea aS Draw In Glucose Test Strip 50 pcs 25 2vials Lancing device Lancets Battery CR2032 3V Control Solution 2 levels Normal and High 2x2ml Note The above supplies and accessories are available in Alliance International Co Ltd or your local distributor Specification of QARE Blood Glucose Meter 1 Dimensions 94 5mm x 56mm x 27 5mm Weight 56g with battery Power Source CR2032 3V lithium coin battery x 1 Battery Life about 500 times or last 10 months without using Display Large LCD Memory 360 results with time and date Automatic power on Electrode inserting detection Sample size luL CON
2. 5 NARE Blood Glucose Monitoring System Owner s Booklet Easy Use Dear i QARE Blood Glucose Monitoring System Owner Thank you for choosing QARE Glucose Monitoring System The QARE Blood Glucose Monitoring System is easy comfortable and convenient to operate also it helps you monitor blood sugar every day This Owner s Booklet will help you understand your QARE Blood Glucose Monitoring System It also provides you with services tools and information helping you to manage your monitoring system and blood sugar To start testing quickly you can also refer to the Quick Start Guide If you have any questions please contact Alliance International Co Ltd Customer Service Center toll free at 1 866 400 3336 or visit www alliance intl com tw Assistance is available 24 hours a day 7 days a week You can also contact your local agent for assistance Again thanks for choosing QARE Blood Glucose Monitoring System INTRODUCTION Welcome to use QARE Blood Glucose Monitoring System DARE Blood Glucose Meter utilizes the latest amperometric biosensor technology to measure blood glucose level In order to keep your meter in good working condition please follow the correct operation procedures in the Owner s Booklet Read this Owner s Booklet carefully and completely before testing your blood glucose To verify the accuracy of any glucose meter or test strip the control solution can be
3. Coding the Meter 1 With the meter off insert the code card into the test strip slot Please make sure the number on the code card matches the code on your display 2 When you insert a test strip see Running a Blood Glucose Test the meter will turn on automatically and show the strip code number Please make sure the code number on the meter screen matches the code on the test strip vial AN Caution 1 Each box of test strip contains one CODE CARD designed specially with one code number REMEMBER to change the CODE CARD every time you open a new box of test strip 2 DO NOT insert different brands or models of CODE CARD or strip which cannot turn on and function the meter Chapter 2 Control Testing Blood Glucose Control Solution 2 Levels To ensure that the glucose meter is operating correctly and obtaining accurate results it 1s recommended to test with a control solution At room temperature Control Solution test results should fall within the expected range printed on the test strip vial label If your values are outside of the range repeat the quality control by using a new test strip If the second result is still outside of the control range please call the service line or national distributor Accurate results also depend upon the meter being properly coded to match the code number printed on each test strip vial label Use of controls for two levels is also recommended in the following conditions
4. For practice purpose to the first time users when using a new glucose meter or a new vial of test strips 1 All levels of control solution should be run with each new lot of test strips 2 Whenever the test strips are exposed to the temperatures above 40 C 104 F or below 14 C 57 2 F After inappropriate operating the equipment When your blood glucose result appears doubtful 5 When your diabetic therapy is changed J Caution Do not use expired control solution The expiration date is printed on each container Upon opening the control solution the date of opening should be noted The control solution can be used for 3 months after initial opening and can be stored at room temperature al Verifying Strip Accuracy Using Control Solution Before measuring your blood glucose level you will need the following materials Your QARE Blood Glucose Meter Fresh QARE Draw In Test Strip Fresh Control Solution CODE CARD Lancing device and Lancets ASE OF gt 1 Place the vial of the test strip in an upright position Take a new test strip from the vial and close the vial lid immediately 2 Insert the test strip into the meter strip slot and open the Control Solution 3 Squeeze a drop of control solution on a clean plastic surface and close the control dla solution vial ll 4 Apply the drop to the application zone of the test strip The solution is automatically drawn in and an audible signal is hear
5. affect the test results in the memory 5 After changing the battery you will have to reset time and date Please refer to Setting Year Time and Date Meter Operational Status Checking 1 Insert CODE CARD firmly into the test strip slot the code number will display on the screen 2 After removing the CODE CARD the upper left side of display will show the symbol Q This symbol means the function of the meter is fully operational 3 If the display DOES NOT show the symbol it means the blood glucose meter is DEFECTIVE and may cause wrong test results Please contact the Distributor P Suggestions Please carefully read this User s Manual of Blood Glucose Meter and Test Strip DO NOT change the diabetic therapy without consulting your physician If the test result is extremely different from your usual test results please contact your physician Please DO NOT expose the new test strips to the air for a long while DO store the test strip in the vial The test strips and the control solution should be used before the expiry date and should be stored in the normal room temperature Please DO NOT refrigerate it If the fresh blood sample has very high density of reducing substrate Vitamins C Uric Acid etc it will affect the value of test result The hematocrit of the blood sample is higher than 55 it will cause the value of the test result to be lower than the normal test
6. result value During the blood glucose test please ensure that the blood sample is fully filled all over the Blood Application Zone yellow square area of the test strip Insufficient blood sample or blood sample flows over the test strip instead of drawing will cause incorrect test results Chapter 6 A Safety and Disposal Glucose Meter 1 Please avoid operating Glucose Meter near devices of generating potential electromagnetic interferences 2 Do not dispose as household waste Dispose according to local regulations 3 Take out battery before disposing 4 Please recycle if possible Used strip lancet and pads 1 Used strips lancets and alcohol pads may be infectious if users have been infected with contagious diseases 2 It is important to treat the used materials as infectious or biologically hazardous wastes 3 Do not dispose as household waste Dispose according to local regulations Battery 1 Before using please ensure that the battery cover is closed 2 Use only approved battery type non approved battery may cause damage 3 Do not dispose as household waste Dispose according to local regulations 4 Do not dispose battery in fire 5 Please recycle if possible NN Caution When testing blood from multiple users disinfect the lancing device and surfaces in contact with blood after each use Dispose the test strips and lancets safely Chapter 7 Screen Message and Troubleshooting Message Descripti
7. 1 minute Remove the test strip and insert the strip in the strip slot again wait until the blood application symbols are shown on the display and draw in the blood sample for testing US cl D A C Eaz LWSEHSMS E a E E a a 1004 15 BSE opi
8. ARD is inserted the display will turn on automatically Each time the meter is on all the symbols should appear briefly Unit Symbol of Test Average of Test Result Memory Message Symbol 7 14 21 28 days Date i Hr Min Smile Symbol iZ IB DAYA BEB B g Meter Checking Status Temperature Message t f OM mmol L Symbol Code Message Code mg dL Out of temp range Blood Application 4 Battery Status A AAA E ey E ATA Test Strip Insertion Test Result Message Connecting or Changing the battery 1 Use your thumb to slide the 2 Slightly pull back the battery cover out of the buckle to loosen the meter battery 3 Place a new battery in a 4 Push the top of the battery 45 degree to the tray with until it is firmly positioned the side facing up The battery symbol cy on the screen means the battery is low and should be changed soon Setting Year Time and Date Setting the time and date is important if you use meter s memory or connect to your computer 1 With meter off press cy 2 Press wa power button to Set button the year will change the year until the flash desired year is displayed 3 Press cy again the month 4 Pres to change the will flash month until the desired month is displayed 2 08 gt 512 D6 5 Repeat step 3 and 4 to dL change day hour minute i and unit J Ht 6 Press od to finish set up and the meter will turn off automatically
9. DARWH Measuring time 6 seconds 10 Sleep Mode Power consumption less than 20uA 11 Automatic power off After 1 minute without action 12 Temperature warning function 13 Operation Condition 14 C 40 C 57 2 F 104 F 14 Storage Transportation Condition 4 C 32 C 39 3 F 89 6 F lt 95 R H 15 Altitude Limit under 2610 meters 8562 ft 16 Measurement Unit mg dL or mmol L Applied Standards This product conforms to the provisions of the FDA 510 K and EC directive IVDD 98 79 EC The following standards apply to the design and or manufacturing of the product IEC 60601 1 Medical electrical equipment Part 1 General requirement for safety IEC60601 1 2 Medical electrical equipment Part 2 Collateral standard Electromagnetic compatibility requirements and test IEC 61010 1 Safety requirements for electrical equipment for measurement control and laboratory use Part 1 General requirement Specification of QARE Draw In Test Strip 1 Strip Size 35mm x 7mm x 0 35mm 2 Required Blood Sample 1uL 3 Hematocrit 30 55 4 Sample Type Fresh capillary whole blood 5 Test Range 20 600 mg dL 6 Operation Condition 14 C 40 C 57 2 F 104 F 7 Validity Can be used within 90 days after opening or within 18 months after the production date 8 Unit of Packaging 25 strips x 2 vials box 9 Storage Transportation Condition 4 C 32 C 39 3F 89 6 F lt 95 R H DO NOT REFRIGERAT
10. E A Caution Do not use any expired strips The strips are only used with QARE glucose meter 3 Do not use any blood that has been preserved e g by fluoride 4 It is not recommended to test the blood level to newborn baby 5 Taking high dose of vitamin C or having high level of uric acid may influence the blood glucose level which may cause inaccurate test results 6 Hematocrit above 55 may cause lower blood glucose level hematocrit lower than 30 may cause higher blood glucose N me 7 To protect the environment dispose of the used lancets and strips in appropriate collection sites according to national or local regulations Avoid other people touching the used lancets or test strips which may cause cross infection 8 Keep the test strip vial away from children the cap is a choking hazard In addition the cap may contain drying agents which can harm the body if swallowed or inhaled It may cause skin or eye irritation Chapter 1 Understanding Your New System Items may be sold separately Test Strip Slot Insert test strip here Display l Shows blood glucose results messages and the results stored in memory Function Button Press this button to enter to the Set Mode move between fields such as time date etc Power Button Press this button to enter or exit the Memory mode or change values in the Set mode Front View Data Slot Transfer date from the meter to a com
11. d for confirming that the test strip took in a sufficient quantity of control solution 5 The measurement appears within 6 seconds Compare it with the range printed on the strips vial Note If the result of your measurement falls within the range shown on the strip vial an accurate blood glucose reading is ensured If the test result falls outside the range the following may apply A The control solution is no longer fresh or the test strip is not sufficiently filled B Ensure the glucose meter is used under 14 C 40 C 57 2 F 104 F and the test strips and the control solution are stored under 4 C 32C 39 3 F 89 6 F lt 95 R H C Ensure the blood sample fully fills the reaction zone of the test strip see below If the above situations occur repeat the measurement at correct temperature utilizing fresh control solutions or a new piece of test strip See Warranty Policy Chapter 3 Testing Your Blood Glucose Preparing lancing device to get blood sample 2 Insert a lancet firmly 1 Twist and pull off the cap 1 Twist and pull ott the cap 3 Twist off the lancet s 4 Snap the cap back on protective cover and twist the cap back to the device Plunger EN 5 Twist the cap to set the 6 Pull the plunger until lancet depth Start at 2 it clicks Set aside to 3 For tougher skin until later in the test dial to a higher number A Caution To reduce the risk of i
12. e test strip Please use a new strip to test again Message Description Proceeding Solution i The glucose meter does Please refer to Coding the iZ 18 IEH not insert the CODE Meter and the use of correct CARD for coding CODE CARD The battery is out of Please change the battery to iZ iB IEH power avoid incorrect test results or else the glucose meter E h cannot be operated Troubleshooting After inserting the QARE DS A Draw In Blood Glucose Test Strip if your Glucose Meter does not display any message or start the test please check the following possible reasons and solutions If you still cannot solve the problem please call our help line at 1 866 400 3336 Reasons Solutions The battery is weak or no battery is Change to a new battery or installed install a battery The battery is installed in the wrong Ensure that the plus sign of direction the battery is facing upward Ensure to insert the introduction zone of the test strip firmly into the strip slot which is located on the top of the meter Then insert the test strip to the end of strip slot The test strip is inserted in wrong direction or is not inserted completely The glucose meter or the test strip is not working The battery is weak or no battery is installed After inserting the test strip and turning on the glucose meter the glucose meter turns off automatically and the glucose meter does not operate for
13. e and Date that information is also stored and displayed with your test results Moreover the Healthy Life Meter can also check the average value of blood glucose results for the past 7 14 21 and 28 days The QARE meter will first display 7 14 21 and 28 days average values as follows 1 With the meter off press wy to turn on the meter 8 88 vaya d8 BB 2 08 12 06 M mmol L Code mg dL gt mg dL edd BUl Cha see cy O TDAYA ig 2 Press vw to display the 7 day average mg dL qn qm Example DAYA m 3 Press WO again to display the 14 day mg dL average By repeating this step you can check the average values of 21 and 28 days f qm Example 4 Press to continue to recall each test result with date and time The display will show the result number 01 first and then Blood Glucose Result Measuring Date and Time Repeat this step to check the following test results 2 18 108 2 18 1608 M mg dL 111 GA Lit y pa 5 To quit the memory recall keep pressing OY to turn off the glucose meter Notes 1 Once the memory is full 360 sets the latest result will cover the oldest one Chapter 5 Caring Cleaning and Maintenance Blood Glucose Meter Caring and Cleaning of Blood Glucose Meter is very easy Follow the instructions below and it will make sure your meter works properly 1 DO NOT disassemble the Blood Glucose Mete
14. ly blood on top surface of test strip When you hear a beep sound you have enough blood in the test strip 7 After finishing the test please use the protective cap to cover the needle eject the lancet and discard it Incorrect Blood Application The strip has insufficient blood in the strip which may result in an error message or inaccurate result Please discard the strip and insert a new test strip to measure again 1 Correct Blood Application The strip has enough blood in the test strip Ensure the blood application zone is fully filled and then remove your fingertip from the test strip Expected Blood Glucose Level Expected blood glucose levels for people without diabetes referenced from the American Diabetes Association Clinical Practice Recommendations 2004 Diabetes Care Vol 27 Supplement 1 P S9 Range mg dL Range mmol L Two hours after meals Less than 140 Less than 7 8 Note 1 If your blood glucose result is unusually high over 300mg dL the user should check the quality control If your blood glucose is under 50mg dL contact your healthcare provider immediately 2 If your blood result appears doubtful repeat the test procedure by using new test strips and running the quality control to ensure that the strip and meter are working properly If the control results are within the ranges on the vials retest your glucose level 3 If you open a new vial of te
15. nfection NEVER share your lancet with anyone 2 When checking the blood glucose level from different users remember to disinfect the lancet cap and the entire surface that has stained with blood after testing It is NOT appropriate to disinfect and reuse the lancet Please dispose the used strip and lancet safely and properly Running a Blood Glucose Test Before running your first test make sure you set up meter properly 1 Use warm water to wash your hands and dry them Then massage your fingertips gently It will be easier to get blood sample with less pain 2 Take one test strip from the vial and close the vial cap rapidly and tightly 3 Insert a test strip make sure the code on the meter matches the code on the test strip vial Notes 1 After taking out the test strip from the vial close the cover of the vial rapidly 2 If the temperature is lower than 14 C or higher than 40 C the LCD screen will display E t message 3 If the code number on the display does not match the code on the test strip vial please contact Alliance International Co Ltd or your local distributor 4 When you see the flashing blood drop hold the lancing device against the side of your fingertip and press the release button 5 Gently squeeze your finger to assist the flow of blood 6 This helps you get a blood drop Touch the drop to the tip of the yellow application zone of the test strip Do not app
16. of a Glucose Meter that has been damaged by accident or has been altered misused tampered with or abused in any way Alliance International Co Ltd will handle meters that show damage or abuse according to its Non Warranty Service Policy described below In no event shall Alliance International Co Ltd be liable to the purchaser or any other person for any incidental consequential or punitive damages arising from or in any ways connect with the purchase the operation of the glucose meter or its parts Non Warranty Service Policy The QARE Blood Glucose Meter Non Warranty Service Policy applies to meters where the above warranty has not become effective has become inapplicable or has expired Alliance International Co Ltd will repair or replace at its option meters returned to it for a service charge Replacement will be the same series or similar product Replacement or repaired meter will be warranted for a period of 90 days from the shipment under a limited warranty providing for replacement of parts and labor at no charge Warranty and Service Instructions All requests for return of the QARE Blood Glucose Meter under the above Warranty or Non Warranty Service Policy must be made to the Customer Service Center by calling 1 866 400 3336 Alliance International Co Ltd or local distributor Customer experiencing difficulties of operating meter should review troubleshooting or Error Message of this manual For m
17. on and Proceeding Solution All the messages will be displayed by symbols or images on the display However when the incorrect operation cause the incorrect test results the glucose meter will not display any messages or symbols for the incorrectness If you still have questions please contact your local Distributor Message Description Proceeding Solution 8 8 Spava 38 88 Every time after starting If there are any symbols OM mmolL your glucose meter please that do not display Code mg dL ensure all the symbols show properly it could cause on the display briefly incorrect test result Please A Please compare it with contact local distributor Cha ma cy Symbols Introduction of the LCD Screen After inserting the CODE Ensure the code number 12 08 rey Si Ni CARD Chip display shall on the display and the Code show the code number and CODE CARD are the y n your measuring unit same Message Description Proceeding Solution i After pressing the be key the Screen shall display the Code Number and the symbol of waiting for test strip to be inserted Code Ou ic Make sure the code number on the screen and on the label of test strip vial are the same Insert the test strip and draw in the blood sample till you hear a beep sound and the test will start After drawing the blood sample into the test strip A iZ iB 24 the 6 second countdown shall star
18. ore information or inquiries please contact Alliance International Co Ltd or local distributor Be sure to fill out your warranty form and return it with your QARE Blood Glucose Meter to Alliance International Co Ltd or the local distributor Alliance International Co Ltd Customer Service No 54 Ying Tao Rd Yingge Dist New Taipei City 239 Taiwan Customer Service Line 1 866 400 3336 Our service is available 24 hours a day 7 days a week E mail service alliance intl com tw National Exclusive Distributor Gustomer Service SING and SYMBO Lot number For in vitro diagnostic use Catalogue number pH Consult instructions for use Temperature limitation MA Caution C f WEEE sis Fulfills the requirement of 98 79 EC FDA Fulfills the requirement of FDA 510 K CONTENT Introduction amp Indication For Use Warranty Contents Standard Kit Contents Supplies and Accessories Specification of QARE Blood Glucose Meter Specification of QARE Draw In Test Strip Chapter 1 Understanding Your New System Introduction of i QARE Draw In Test Strip Symbols Introduction of the LCD Screen Connecting or changing the Battery Setting Year Time and Date Coding the Meter Chapter 2 Control Testing Control Solution Chapter 3 Testing Your Blood Glucose Running a Blood Glucose Test Expected Blood Glucose Value Chapter 4 Using Your Meter Memory 30 Chapter 5 Care Cleaning and Maintenance
19. purchased from your local distributor INDICATION FOR USE The QARE DS A Blood Glucose Monitoring System is used with the QARE DS A Draw In Blood Glucose Test Strips and 2 level Controls for the measurement of glucose in whole blood Testing is done outside the body in vitro diagnostic use It is indicated for use at home over the counter OTC by person with diabetes or in clinical setting by health care professionals as an aid to monitor the effectiveness of diabetes control It is not intended for the diagnosis of or screening for diabetes mellitus and is not intended for use on neonates The frequent monitoring of blood glucose is an adjunct to the care of persons with diabetes WARRANTY 5 Year Warranty Alliance International Co Ltd warrants to the original purchaser of the meter that your QARE Blood Glucose Meter will be free from defects in materials and workmanship for 5 years from the date of purchase If the meter does not work properly because of the defect in material or workmanship during this 5 year period Alliance International Co Ltd will repair it or replace it with a new QARE Blood Glucose Meter The warranty of the repaired or replacement meter will expire on the date of the original warranty expiration or 90 days after the shipment of a replacement meter whichever period is longer This warranty applies only to the original purchaser of the meter This warranty does not apply to the performance
20. puter Side View Battery Cover Slide out cover to change battery l l q Lanyard Hole A Back View n Code Card Cap with Comfort Dial Plunger Depth Selection 1 Release Button i y y EZ Cover Protective l dO L Ejector i gt l Reaction Zone Test Strip Lancet Introduction of Draw In Test Strip Reaction Zone gt M Introduction Zone Application Zone 1 Reaction Zone This is located in the middle of the test strip This area must be completely filled with blood sample 2 Application Zone This is located on the top side of the reaction zone When a drop of blood is applied to the reaction zone it will be rapidly drawn in 3 Introduction Zone On the test strip black bars are located in the bottom area and it must be inserted into the strip slot of the meter with the black bars facing up N Caution 1 Blood sample should not be applied to the Introduction Zone black bars 2 Avoid touching the reaction and application zones for long periods as moisture may affect the reaction and reading Symbols Introduction of the LCD Screen Display Symbols The blood glucose meter displays symbols to guide you through the test and to assist you to determine whether the test strip and display function are ready or not To check that all the display symbols are working press the power button or insert the test strip electrodes into the meter When a test strip or CODE C
21. r If there is any problem please contact the Distributor for assistance 2 Please carry or hold the Blood Glucose Meter carefully to avoid extreme shock or accidental drop down 3 The Blood Glucose meter should work or be used under the temperature environment between 14 C 40 C 57 2 F 104 F 4 DO NOT expose the Blood Glucose Meter and Test Trip to extreme hot temperature high humidity Kitchen or bathroom or direct sunlight 5 DO NOT use abrasive cleaners and never submerge the body of the blood Glucose Meter in water or other liquids For proper cleaning use a soft dry lint free cloth to clean the body of the Meter and lancing device Cleaning Your Lancing Device To clean your lancing device use a mild dishwashing liquid and a soft cloth DO NOT place the entire device under water At least once a week disinfect the cap after cleaning by placing it in 70 alcohol isopropyl for 10 minutes Rinse with water and allow the cap to air dry after disinfecting Battery 1 3V Lithium coin battery can support approximately 500 times of blood glucose test When the battery needs to be changed please use ONLY CR2032 3V Lithium coin battery or the same kind of 3V Lithium coin battery 2 When the LCD screen display the symbol 3 please change the battery immediately in order to avoid wrong test results 3 Steps of changing the battery please refer to Connecting or Changing the Battery 4 Changing the battery will not
22. st strips ensure the code on the vial matches the code on the meter If the code does not match calibrate with a new CODE CARD Once the code number on the meter is displayed insert the strip from the new vial into the meter Understanding Your Test Result The Blood Glucose Value is variable and will be affected by different elements For example 1 Measuring blood glucose level at different times in a day 2 Types of food you eat 3 Body condition 4 Insulin and medicines etc High Blood Glucose Value If the Blood Glucose Value is too high or you have symptoms such as thirst pyuria regurgitation vomiting dystopia somnolence belly ache please consult with your physician immediately Low Blood Glucose Value If the Blood Glucose Value is too low or you have the symptoms such as night sweat cold to shake palpitating headache dystopia dizzy tachycardia tinnitus paralysis of fingertip please consult with your physician immediately Unusual Test Results If your blood sugar result doesn t match the way you feel follow these steps 1 Run a control test 2 Repeat a blood glucose test If your blood glucose results still don t reflect the way you feel call your doctor immediately Chapter 4 Using Your Meter Memory Storing Test Result Your meter automatically stores up to 360 test results and you can review them at any time If you have set the time and date on the meter see Setting Year Tim
23. t After the countdown is finished the Ub rest result will display on the screen NONE Your blood glucose may be iZ iB IEH extremely low If it is lower than 20mg dL Iri LLI Ensure the test strip has drawn in sufficient blood sample to the blood application zone and test again with new strip If it is still displaying the LO symbol please consult with your physician ha iB i EPH Your blood glucose may be extremely high If it is higher than 600mg dL Hi Make a new test with new test strip again If it is still displaying the HI symbol please consult with your physician Message Description Proceeding Solution The Test Result will be After entering the Memory iZ 18 f amp e4 stored in the memory Mode press Lo Key M mg dL to recall saved Blood 00 Glucose Results with date and time The memory can record the latest 360 Blood Glucose Results Result for the past 7 14 21 and 28 days After entering the memory mode press wy key to see the average value of blood glucose result for the past 7 14 21 and 28days sequentially If the temperature is iZ iB ftey E E extremely high or low during the operation of the glucose meter Move to an area between 14 C 40 C 57 2 F 104 F wait 5 minutes and repeat the test The test strip is used or iZ iB ruda damaged E U Please DO NOT reuse th