1. Digital Storage Oscilloscopes TDS2000C Series Datasheet Tektronix TDS 2024 ee M Poe 268 0r The TDS2000C Digital Storage Oscilloscope Series provides you with affordable performance in a compact design Packed with standard features including USB connectivity 16 automated measurements limit testing data logging and context sensitive help the TDS2000C Series oscilloscopes help you get more done in less time Key performance specifications 200 MHz 100 MHz 70 MHz 50 MHz bandwidth models 2 and 4 channel models Up to 2 GS s sample rate on all channels 2 5k point record length on all channels Advanced triggers including pulse width trigger and line selectable video trigger Key features 16 automated measurements and FFT analysis for simplified waveform analysis Built in waveform limit testing Automated extended data logging feature Autoset and signal auto ranging Built in context sensitive help Probe check wizard 11 language user interface 144mm 5 7 inch active TFT color display Small footprint and lightweight only 124 mm 4 9 inches deep and 2 kg 4 4 Ib USB 2 0 host port on the front panel for quick and easy data storage USB 2 0 device port on the rear panel for easy connection to a PC or for direct printing to a PictBridge compatible printer Includes National Instrument s LabVIEW SignalExpress TE Limited Edition and Tektronix OpenChoice Soft
2. Data Logging enables automatic saving of triggered waveforms CH1 1 00 TDS2000C Di gital Storage Oscilloscopes Conveniently use your USB flash drive to store screenshots and waveform data Easy PC connectivity Easily capture save and analyze measurement results by connecting to your PC with the rear panel USB device port and the included copy of OpenChoice PC Communications Software Simply pull screen images and waveform data into the stand alone desktop application or directly into Microsoft Word and Excel Alternatively if you prefer not to use your PC you can simply print your image directly to any PictBridge compatible printer Connect to your bench for intelligent debug Every TDS2000C Series oscilloscope ships with an included copy of the Limited Tektronix Edition of National Instrument s LabView SignalExpress for basic instrument control data logging and analysis SignalExpress supports the range of Tektronix bench instruments For a complete listing of Tektronix instruments supported by NI LabView Signal Express visit www tektronix com signalexpress enabling you to connect your entire test bench You can then access the feature rich tools packed into each instrument from one intuitive software interface This allows you to automate complex measurements requiring multiple instruments log data for an extended period of time time correlate data from multiple instruments and easily capture and analyze your re
3. 6 0 8 8 6 6 6 0 om onets 8 6 68 O68 68 6 O88 8 88 8 8 a 8G Ce Rising sr raeeetns Normal CHI J 536m lt 10H2 See all the details other oscilloscopes might miss with Tektronix proprietary digital real time sampling CH1 200mm Acq Complete Pos 12 50MHz MATH eet eee ee ere ete teeta FFT CH1 Hanning a 20MH CoO0M Ss Hanning arh dr3Hz CH1 10 006 Quickly perform an FFT with the advanced math functions 2 www tektronix com Noise Reject Designed to make your work easy The TDS2000C Series oscilloscopes are designed with the ease of use and familiar operation you have come to expect from Tektronix Intuitive operation The intuitive user interface with dedicated per channel vertical controls auto setup and auto ranging makes these instruments easy to use reducing learning time and increasing efficiency Help when you need it The built in Help menu provides you with important information on your oscilloscope s features and functions Help is provided in the same languages as the user interface lt graticule gt Use multipurpose knob to scroll The context sensitive Help system provides important information specific to the task you are working on Probe check wizard Check out your probe compensation before making measurements with just one button that starts a fast easy procedure Limit test The oscilloscope can automatically monitor source signals and output
4. 1 EU Low Voltage Directive 2006 95 EC 8 www tektronix com TDS2000C Digital Storage Oscilloscopes Ordering information Models TDS2001C 50 MHz 2 Ch 500 MS s TFT DSO TDS2002C 70 MHz 2 Ch 1 GS s TFT DSO TDS2004C 70 MHz 4 Ch 1 GS s TFT DSO TD 2012C 100 MHz 2 Ch 2 GS s TFT DSO TDS2014C 100 MHz 4 Ch 2 GS s TFT DSO TDS 2022C 200 MHz 2 Ch 2Gs s TFT DSO TDS 2024C 200 MHz 4 Ch 2 GS s TFT DSO Instrument options Language options Opt LO English front panel label on instrument Opt L1 French front panel overlay Opt L2 Italian front panel overlay Opt L3 German front panel overlay Opt L4 Spanish front panel overlay Opt L5 Japanese front panel overlay Opt L6 Portuguese front panel overlay Opt L7 Simplified Chinese front panel overlay Opt L8 Traditional Chinese front panel overlay Opt L9 Korean front panel overlay Opt L10 Russian front panel overlay User manual PDF in 11 languages are available on the documentation CD and for download from www tektronix com manuals There are no printed user manuals Power plug options Opt A0 North America power plug 115 V 60 Hz Opt A1 Universal Euro power plug 220 V 50 Hz Opt A2 United Kingdom power plug 240 V 50 Hz Opt A3 Australia power plug 240 V 50 Hz Opt A4 North America power plug 240 V 50 Hz Opt A5 Switzerland power plug 220 V 50 Hz Opt A6 Japan power plug 100 V 110 120 V 60 Hz Opt A10 China power plug 50
5. Hz Opt A11 India power plug 50 Hz www tektronix com 9 Datasheet Opt A12 Opt A99 Service options Opt D1 Brazil power plug 60 Hz No power cord Calibration Data Report Probes and accessories are not covered by the oscilloscope warranty and Service Offerings Refer to the datasheet of each probe and accessory model for its unique warranty and calibration terms Standard accessories Probes TPP0101 TPP0201 Accessories Power cord NIM NIST Documentation OpenChoice PC Communications Software National Instruments SignalExpress Tektronix Edition Interactive Measurement Software base version Limited Lifetime Warranty 10 www tektronix com 100 MHz passive probe for TDS2001C TDS2002C and TDS2004C one per channel 200 MHz passive probe for TDS2012C TDS2014C TDS2022C and TDS2024C one per channel Please specify plug option Traceable Certificate of Calibration TDS2000C and TDS1000C EDU Compliance and Safety Instructions TDS2000C and TDS1000C EDU Documentation CD Enables fast and easy communication between a Windows PC and the TDS2000C Series using USB Transfer and save settings waveforms measurements and screen images A fully interactive measurement software environment optimized for the TDS2000C Series Enables you to instantly acquire generate analyze compare import and save measurement data and signals using an intuitive drag and drop user interface that does not require any prog
6. Pass or Fail results by judging whether the input waveform is within predefined boundaries Specific actions can be triggered on violation including stopping waveform acquisition stopping Limit Test functions saving the failed waveform data or screen image to a USB memory device or any combination of the above This is an ideal solution for manufacturing or service applications where you need to make decisions quickly Trig d i i rir rire i int tit E E E i iit ks E ead E ay r P id iF T i z 2 Aun d qos Limit Test provides a quick Pass Fail comparison of any triggered input signal to a user defined template Flexible data transfer The USB host port on the front panel enables you to save your instrument settings screenshots and waveform data in a flash The built in Data Logging feature means you can set up your oscilloscope to save user specified triggered waveforms to a USB memory device for up to 24 hours You can also select the infinite option for continuous waveform monitoring With this mode you can save your triggered waveforms to an external USB memory device without a duration limitation until the memory device is full The oscilloscope will then guide you to insert another USB memory device to continue saving waveforms A Ready CH1 2 we wde w FP ge ehe ee ee ee ee et mee ee ee et ie KAAU SKUE T EN E U E 1 hour CH1 JL 1 067 lt 10H2
7. an toll free number If not accessible call 41 52 675 3777 Austria 00800 2255 4835 Brazil 55 11 3759 7627 Central Europe amp Greece 41 52 675 3777 France 00800 2255 4835 India 000 800 650 1835 Luxembourg 41 52 675 3777 The Netherlands 00800 2255 4835 Poland 41 52 675 3777 Russia amp CIS 7 495 6647564 Sweden 00800 2255 4835 United Kingdom amp Ireland 00800 2255 4835 Balkans Israel South Africa and other ISE Countries 41 52 675 3777 Canada 1 800 833 9200 Denmark 45 80 88 1401 Germany 00800 2255 4835 Italy 00800 2255 4835 Mexico Central South America amp Caribbean 52 55 56 04 50 90 Norway 800 16098 Portugal 80 08 12370 South Africa 41 52 675 3777 Switzerland 00800 2255 4835 USA 1 800 833 9200 Updated 10 April 2013 For Further Information Tektronix maintains a comprehensive constantly expanding collection of application notes technical briefs and other resources to help engineers working on the cutting edge of technology Please visit www tektronix com Copyright Tektronix Inc All rights reserved Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supersedes that in all previously published material Specification and price EX change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc All other trade names referenced are the service marks trademarks or registered trademarks of their respectiv
8. e companies say 12 Apr 2013 www tektronix com 3GW 25645 4 Tektronix
9. e time limit ranging from 33 ns to 10 s CH1 CH2 Ext Ext 5 AC Line CH1 CH2 CH3 CH4 Ext Ext 5 AC Line Displays the trigger signal while the Trigger View button is depressed Provides a frequency readout of the trigger source www tektronix com 5 Datasheet Acquisition system Acquisition modes Peak detect Sample Average Single sequence Roll mode Waveform measurements Automatic waveform measurements Cursors Types Measurements Waveform math Operators Sources 2 channel models 4 channel models FFT Autoset menu Square wave Sine Wave Video NTSC PAL SECAM Autorange Display characteristics Display Interpolation Display types Persistence Format 6 www tektronix com High frequency and random glitch capture Captures glitches as narrow as 12 ns typical at all time base settings from 5 us div to 50 s div Sample data only Waveform averaged selectable 4 16 64 128 Use the Single Sequence button to capture a single triggered acquisition sequence At acquisition time base settings of gt 100 ms div Period Frequency Width Width Rise Time Fall Time Max Min Peak to Peak Mean RMS Cycle RMS Cursor RMS Duty Cycle Phase Delay Amplitude and time AT 1 AT frequency AV Add Subtract Multiply FFT CH1 CH2 CH2 CH1 CH1 CH2 CH1 x CH2 CH1 CH2 CH2 CH1 CH3 CH4 CH4 CH3 CH1 CH2 CH3 CH4 CH1 x CH2 CH3 x CH4 Windows Hanning Flat Top Rectangu
10. er input Included on all models Sample rate on each channel 500 MS s 1 0 GS s 1 0 GS s 2 0 GS s 2 0 GS s 2 0 GS s 2 0 GS s Vertical system Record length Vertical resolution Vertical sensitivity DC vertical accuracy Vertical zoom Maximum input voltage Position range Bandwidth limit Input impedance Input coupling Horizontal system Time base accuracy Horizontal zoom Trigger system Trigger modes Trigger types Edge rising falling Video Pulse width or glitch Trigger source 2 channel models 4 channel models Trigger view Trigger signal frequency readout 2 5k points at all time bases on all models 8 bits 2 mV to 5 V div on all models with calibrated fine adjustment 3 on all models Vertically expand or compress a live or stopped waveform 300 Vrms CAT Il derated at 20 dB decade above 100 kHz to 13 V AC at 3 MHz 2 mV to 200 mV div 2 V gt 200 mV to 5 V div 50 V 20 MHz for all models 1 MQ in parallel with 20 pF AC DC GND on all models 50 ppm Horizontally expand or compress a live or stopped waveform Auto Normal Single Sequence Conventional level driven trigger Positive or negative slope on any channel Coupling selections AC DC Noise Reject HF Reject LF Reject Trigger on all lines or individual lines odd even or all fields from composite video or broadcast standards NTSC PAL SECAM Trigger on a pulse width less than greater than equal to or not equal to a selectabl
11. h voltage active differential probe 25 MHz P6021 15 A 60 MHz AC current probe A621 2000 A 5 to 50 kHz AC current probe A622 100 A 100 kHz AC DC current probe BNC TCP303 TCPA300 150 A 15 MHz AC DC current probe amplifier TCP305 TCPA300 50 A 50 MHz AC DC current probe amplifier TCP312 TCPA300 30 A 100 MHz AC DC current probe amplifier TCP404XL TCPA400 500 A 2 MHz AC DC current probe amplifier Accessories TEK USB 488 GPIB to USB converter SIGEXPTE National Instruments SignalExpress Tektronix Edition Internative Measurement Software Professional Version AC2100 Soft carrying case for instrument HCTEK4321 Hard plastic carrying case for instrument RM2000B Rackmount kit 077 0444 xx Programmer manual English only PDF only downloadable from www tektronix com manuals 077 0446 xx Service manual English only PDF only downloadable from www tektronix com manuals 174 4401 xx USB host to device cable 3 feet long GPIB Product s complies with IEEE Standard 488 1 1987 RS 232 C and with Tektronix Standard Codes and Formats IEEE 488 www tektronix com 11 Datasheet ASEAN Australasia 65 6356 3900 Belgium 00800 2255 4835 Central East Europe and the Baltics 41 52 675 3777 Finland 41 52 675 3777 Hong Kong 400 820 5835 Japan 81 3 6714 3010 Middle East Asia and North Africa 41 52 675 3777 People s Republic of China 400 820 5835 Republic of Korea 001 800 8255 2835 Spain 00800 2255 4835 Taiwan 886 2 2722 9622 Europe
12. ional Two 2 5k point reference waveforms TDS2001C TDS2002C TDS2012C TDS2022C Two 2 5k point waveforms TDS2004C TDS2014C TDS2024C Four 2 5k point waveforms 64 GB 96 or more reference waveforms per 8 MB 10 front panel setups 4 000 or more front panel setups per 8 MB 128 or more screen images per 8 MB The actual number of images depends on the file format selected 12 or more Save All operations per 8 MB A single Save All operation creates 3 to 9 files setup image plus one file for each displayed waveform Full range 100 to 240 Vac RMS 10 Installation Category II covers range of 90 to 264 Vac Power consumption Less than 30 W at 85 to 275 Vac input 158 0 mm 6 2 inches 326 3 mm 12 8 inches 124 2 mm 4 9 inches 2 0 kg 4 4 Ib 2 2 kg 4 9 Ib 266 7 mm 10 5 inches 476 2 mm 18 7 inches 228 6 mm 9 0 inches 482 6 mm 19 0 inches 177 8 mm 7 0 inches 108 0 mm 4 3 inches www tektronix com 7 Datasheet EMC environment and safety Temperature Operating 0 to 50 C Non operating 40 to 71 C Humidity Operating Up to 80 RH at or below 40 C Up to 45 RH up to 50 C Non operating Up to 80 RH at or below 40 C Up to 45 RH up to 50 C Altitude Operating Up to 3 000 m Non operating Up to 3 000 m Electromagnetic compatibility Meets Directive 2004 108 EC EN 61326 2 1 Class A Australian EMC Framework Safety UL61010 2004 CSA22 2 No 61010 1 2004 EN61010 1 2001 IEC61010 1 200
13. lar 2 048 sample points Single button automatic setup of all channels for vertical horizontal and trigger systems with undo Autoset Autoset menu signal type choices are Single Cycle Multicycle Rising or Falling Edge Single Cycle Multicycle FFT Spectrum Field Alt Odd or Even Line Alt or Selectable Line Number Automatically adjust vertical and or horizontal oscilloscope settings when a probe is moved from point to point or when a signal exhibits large changes QVGA Active Color TFT Sin x x Dots vectors Off 1s 2 s 5 s infinite YT and XY Input output interfaces USB Ports GPIB Nonvolatile storage Reference waveform display Waveform storage without USB flash drive Maximum USB flash drive size Waveform storage with USB flash drive Setups without USB flash drive Setups with USB flash drive Screen images with USB flash drive Save All with USB flash drive Power source Power source Source voltage Power consumption Physical characteristics Instrument dimensions Height Width Depth Instrument weight Instrument only Instrument with accessories Shipping package dimensions Height Width Depth RM2000B rackmount dimensions Height Width Depth TDS2000C Digital Storage Oscilloscopes The USB host port on the front panel supports USB flash drives The USB device port on the back of the instrument supports connection to a PC and to all PictBridge compatible printers Opt
14. ramming Standard TDS2000C Series support for acquiring controlling viewing and exporting your live signal A 30 day trial period of the Professional Version provides additional signal processing advance analysis mixed signal sweeping limit testing and user defined step capabilities Order SIGEXPTE for permanent Professional Version capability Covers labor and parts for defects in materials and workmanship for a minimum of 10 years excluding probes and accessories Lifetime is defined as 5 years after Tektronix discontinues manufacturing the product but the warranty length shall be at least ten years from date of original purchase Lifetime warranty is nontransferrable Proof of original purchase is required Limitations apply For terms and conditions visit www tektronix com lifetimewarranty Probes and accessories are not covered by the oscilloscope warranty and Service Offerings Refer to the datasheet of each probe and accessory model for its unique warranty and calibration terms TDS2000C Digital Storage Oscilloscopes Recommended accessories Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar Probes TPP0101 10X passive probe 100 MHz bandwidth TPP0201 10X passive probe 200 MHz bandwidth P2220 1X 10X passive probe 200 MHz bandwidth P6101B 1X passive probe 15 MHz 300 Vans CAT II rating P6015A 1000X high voltage passive probe 75 MHz P5100A 100X high voltage passive probe 500 MHz P5200 Hig
15. sults all from your PC Only Tektronix offers a connected test bench of intelligent instruments to simplify and speed debug of your complex design www tektronix com 3 Datasheet Performance you can count on Untitled 1 LabVIEW SignalExpress Joe Fie Edt View Took AddStep Dataview Window Help In addition to industry leading service and support every TDS2000C Series oscilloscope comes backed with a Lifetime Warranty as standard Q Add Sep Run lt Pun Once Record Tig Add Display A Dock 1 Show Help j 3z Stap Setup Data View 3 Recording Optons _ Project Documentation E5 Tek Tos100072000 Limitations apply For terms and conditions visit www tektronix com Lee qe lifetimewarranty jb E TOS 2024C10H2 Freq 2 log A Snapshots g 1 i 10 15 2 5 Hn 53 0 6 amp DS SM Iteration Easily capture save and analyze measurement results with the included National Instrument s LabVIEW SlgnalExpress Limited Tektronix Edition software 4 www tektronix com TDS2000C Digital Storage Oscilloscopes Specifications All specifications apply to all models unless noted otherwise Overview TDS2001C TDS2002C TDS2004C TDS2012C TDS2014C TDS2022C TDS2024C Display QVGA LCD TFT on all models Bandwidth 50 MHz 70 MHz 70 MHz 100 MHz 100 MHz 200 MHz 200 MHz Channels 2 2 4 2 4 2 4 External trigg
16. ware for connecting to your bench Lifetime warranty Limitations apply For terms and conditions visit www tektronix com lifetimewarranty Digital precision for accurate measurements With up to 200 MHz bandwidth and 2 GS s maximum sample rate no other digital storage oscilloscope offers as much bandwidth and sample rate for the price Tektronix proprietary sampling technology provides real time sampling with a minimum of 10X oversampling on all channels all the time to accurately capture your signals Sampling performance is not reduced when using multiple channels Critical tools for troubleshooting your device Advanced triggers rising falling edge pulse width and video help you quickly isolate your signals of interest Once you ve captured a signal advanced math capabilities and automated measurements can speed your analysis Quickly perform an FFT or add subtract or multiply waveforms Sixteen automated measurements quickly and reliably calculate important signal characteristics such as frequency or rise time while the built in Limit Test function enables you to easily identify problems in your signal Mi Pos 24 80 u5 TRIGGER Type Source CH4 When Pulse Width 2 34 US more page 1of2 M 10 0 us 12 Aug 10 14 40 Quickly and easily capture waveforms with advanced triggering Tektronix Datasheet A Ready ee sg a eae oa a Dennett eens Edge CH1 aaa nc e824 8 8 4 9 6 6