TR-1000VA-48VDC User Manual

image

Contents

1. in the OFF position Turn ON the inverter and the inverter should supply power to the load 7 TR 1000VA 48VDC User Guide INSTALLATION 1 Where To Install The power inverter should be installed in a location that meets the following requirements a Dry Do not allow water to come in contact with the inverter b Cool Ambient air temperature is between 0 C 40 C c Ventilated Allow at least 1 of clearance around the inverter for airflow Ensure the ventilation openings on the rear and bottom of the unit are not obstructed d Safe Do not install the inverter in the same compartment as batteries or in any compartment capable of storing flammable liquids such as gasoline Cables DC to AC inverters require high amperage low voltage DC power to low amperag high voltage AC power To operate properly connect inverter DC input terminals directly to the battery with the heaviest wire available see chart below Max Output Req d Wire 8 TR 1000VA 48VDC User Guide TR1000VA 48VDC RACK MOUNT VERSION showing installation of chassis slides 7 INTERMEDIATE SEC TOON REAG MOUNT 1G RIGHT SIDE MOUNT POR FLUSH ao STATIONARY MOUNTING COUNTERS 440 FLAT HEAD SCREWS __ FRONT MOUKTING RAIL RIGHT SIDE 9 TR 1000VA 48VDC User Guide 3 Grounding AC Safety Grounding During the AC wiring installation AC output gro
2. TRANSDUCTION 1000 VA 48 VDC 120 VAC INVERTER TRANSDUCTION Model TR 1000VA OUTPUT 833 USER S MANUAL Version 1 0 10 20 08 TR 1000VA 48VDC Pure Sine Wave Inverter 48 V DC to 120 V AC 50 60 Hz 5155 23 Spectrum Way Mississauga ON Canada L4W 5A1 TEL 1 800 268 0427 905 625 1907 FAX 905 625 0531 Email sales transduction com Important Information The information in this document is subject to change without notice All relevant issues have been considered in the preparation of this document Should you notice an omission or any questionable item in this document please feel free to notify Transduction Regardless of the foregoing statement Transduction assumes no responsibility for any errors that may appear in this document nor for results obtained by the user as a result of using this product Copyright 2005 Transduction All rights reserved This document is protected by copyright No part of this document may be repro duced copied or translated in any form or means without prior written permission from Transduction All other trademarks brand and product names are the property of their respec tive owners Return policy Warranty is 3 years from the date of purchase Products returned for repair must be accompanied by a Return Material Authorization RMA number obtained from Transduction prior to return Freight on all returned items must be prepaid by the customer The customer is responsible for
3. any loss or damage caused by the carrier in transit To obtain an RMA number call us at 905 625 1907 We will need the following information Return company address and contract Model name model number and serial number Description of the failure Mark the RMA number clearly on the outside of each box include a failure report and return the product to Transduction 5155 23 Spectrum Way Mississauga ON Canada L4W 5A1 Attn RMA Department Index Safety Precautions 4 General luce cana 5 EO OU COM 5 Rear View Rack Mount Version 6 Quick Hookup and 7 8 10 TR 1000VA 48VDC Rack Mount Version 9 CPST AT ON eee renee Sa pees 10 11 11 12 Specificati NS 13 For Service and Support 14 Safety Precautions WARNING Before installing and using the inverter please read the safety precautions General Safety Precautions Do not expose the inverter to rain snow spray bilge or dust To reduce risk of hazard do not cover or obstruct the ventilation openings To avoid risk of fire and electrical shock make sur
4. e that existing wiring is in good electrical condition and that wire size is not underrated Do not operate the inverter using damaged or substandard wiring Explosive Gas Precautions This equipment contains components which can produce arcs or sparks To prevent fire or explosion do not install inverter in any compartments containing batteries or flammable materials or in locations which require ignition protected equipment This includes any space containing gasoline powered machinery fuel tanks and any fittings or other connections between components of the fuel system Precautions When Working with Batteries If battery acid contacts skin or clothing immediately wash with soap and water If acid enters the eye immediately flush eye with cold running water and keep flushing it for at least 20 minutes Seek medical attention immediately NEVER smoke allow sparks or open flames near the battery or engine Do not drop metal tools on the battery The resulting spark or short circuit may cause an explosion Remove personal jewelry items when working with lead acid batteries The short circuit current produced is high enough to cause severe burns 4 TR 1000VA 48VDC User Guide GENERAL FEATURES Pure sinewave ouput lt 2 THD Input and ouput isolation High efficiency 87 90 High surge capacity inductive loads Soft start technology Frequency 50 60Hz switchable Auto restart 2U rack mount 3 year
5. on TR 1000VA 48VDC will auto re start 5 times If itis not successful the inverter will shut down automatically 10 TR 1000VA 48VDC User Guide Overtemp There will be a sound tone if the temperature is too high then the inverter will automatically shut down Re set the inverter after it cools down NOTE The speed of the fan will be change to follow the inverter internal temperature Input Voltage The power inverter will operate from output voltage range 42 64VDC Frequency Switchable Adjust 50 60Hz with the internal button Sound tone will begin to indicate fre quency level Sound tone 1 indicates 50Hz 2 indicates 60Hz on the inverter again when frequency has been changed TROUBLESHOOTING GUIDE Problem Possible Cause Solution Check for fault with battery charging system Manually reset inverter by turning switch ON Battery voltage is High Batt Shutdown too high Charge battery Low Batt Sound Battery voltage is Manually reset Tone Shutdown too low inverter by turning switch ON Battery current too Overload Shutdown high probable AC overload Reduce load on the inverter Improve ventilation Overtemp Sound System temperature and cooling and or Tone Shutdown is too high reduce load on inverter Ensure all loads are disconnected Reset the unit by switching to ON If unit still does not operat contact distributor merchant for service warranty replacement Overload o
6. ositive and black terminal is negative Connect the cables into the terminals and tighten the wing nut to clamp the wires securely Connect the cable from the negative terminal of the inverter to the negative terminal of the power source Make a secure connection NOTE Loosely tightened connectors result in excessive drop and may cause overheated wires and melted insulation Before proceeding further double check that the cable you have just connected to the negative terminal of the inverter is connected to the negative output terminal of the power source NOTE Reverse polarity connection will blow a fuse on the inverter and may cause permanent damage Damage caused by reverse polarity connection is not covered under warranty Connect the cable from the positive terminal of the inverter to the positive terminal of the power source Make a secure connection NOTE There may be a spark when this connection is made since current may flow to charge capacitors in the power inverter Do not make the connection in the presence of flammable fumes explosion or fire may result Turn ON the inverter and check the indicators on the front panel The meters should show a reading If it does not check your power source and the connections The other indicators should be off Turn OFF the inverter The internal alarm may sound briefly This is normal Plug the test load in to the AC receptacle on the front panel of the inverter Keep the switch
7. r system hardware fault System Shutdown 11 TR 1000VA 48VDC User Guide MAINTENANCE Very little maintenance is required to keep the inverter operating properly Clean the exterior of the unit periodically with a damp cloth to prevent accumulation of dust and dirt At the same time tighten the screws of the DC input terminals 12 TR 1000VA 48VDC User Guide SPECIFICATIONS Model Continuous Ouput Power Max Peak Power DC Input Voltage AC Ouput Voltage Frequency Input Output Isolation Efficiency No Load Current Draw Output Wave Form Distortion Temperature Protection Input Low Voltage Protection Input Low Voltage Alarm Input Reverse Polarity Circuit Protection Output Short Circuit Protection Overload Protection Redundant Ball Bearing Air Fans Auto Restart From Loss of Input Power Dimensions x W x H inches Net Weight KG Gross Weight KG CE Compliance TR 1000VA 48VDC 1000W 2400W 42 64V 120VAC 50 60Hz 3 Yes 87 0 3A Pure Sine Wave lt 2 THD lt 2 55 C 5 C Yes Yes Yes Yes Yes Yes Yes 17x 19 3 5 6 0 8 0 Yes 13 TR 1000VA 48VDC User Guide FOR SERVICE AND SUPPORT CONTACT Transduction 5155 Spectrum Way Bldg 23 Mississauga ON L4W 5A1 Canada Toll Free 1 800 268 0427 Telephone 905 625 1907 Fax 905 625 0531 email sales transduction com 14 TR 1000VA 48VDC User Guide
8. und wires are connected to the Inverter The AC output ground wire should go to the grounding point for your loads Neutral Grounding The neutral conductor of the AC output circuit of the Inverter is automatically connected to the safety ground during Inverter operation This conforms to National Electric Code requirements Connecting Battery Cables to the DC Input Terminals Cables should be less than 10 feet long 3 meters and the correct gauge to handle the required current in accordance with the codes regulations applicable to your installation Incorrect cabling will decrease Inverter performance and may cause poor surge handling voltage warnings and shutdowns NOTE Do not operate the power inverter without connecting it to ground Electrical shock may occur OPERATION To operate the power inverter turn it on using the ON OFF switch on the front panel The power inverter is now ready to deliver AC power to various loads If operating several loads from the power inverter Turn them on seperately after the inverter has been turned on This will ensure that the power inverter does not have to deliver the starting currents for all the loads at once NOTE The ON OFF switch turns the control circuit in the power inverter on and off It does not disconnect power from the power inverter OPERATING LIMITS Overload Auto Re Start The inverter operates most AC loads within its power rating If the load is over the specificati
9. warranty INTRODUCTION The TR 1000VA 48VDC power inverter is one of the most advanced power systems available To get the most out of the power inverter it must be installed and used properly Please read the instructions in this manual before installing and using 5 TR 1000VA 48VDC User Guide REAR VIEW RACK MOUNT VERSION Cooling Fans Do not obstruct Allow at least 1 inch clearance for air flow Battery Terminals Check that the inverter voltage is compatible with your supply i e a 48V inverter on a 48V system Using the spanner and cables provided connect to 48V battery or other 48V power source NOTE Reverse polarity connection will blow internal fuses and may permanently damage the inverter Ground Chassis ground or to vehicle chassis using 8AWG wire NOTE Operation without a proper ground connection may result in electrical hazard SHOCK HAZARD WARNING Before proceeding any further ensure that the inverter is NOT connected to any batteries and that all wiring is disconnected from any electrical sources Do not connect the output terminals of the inverter to an incoming AC source 6 TR 1000VA 48VDC User Guide QUICK HOOKUP AND TESTING To check performance before proceeding with the installation do the following 1 Unpack and inspect the inverter Make sure the power switch is in the OFF position Connect the cables to the power input terminals on the rear panel of the power inverter The red terminal is p