1. 45 OSCILLATION ANGLE CON NECT THE OSCILLATION LINK TO THE INNERMOST HOLE IN THE CAM GEAR MAINTENANCE WARNING ALWAYS UNPLUG THE CORD BEFORE MOV ING OR SERVICING WARNING DO NOT IMMERSE FAN IN WATER CLEANING Use a soft cloth and mild soap solution such as liquid dish washing detergent Dry all parts completely before reconnect ing to power supply CAUTION Do not use gasoline benzine thinner harsh cleaners etc as they will damage the Fan NEVER use ALCOHOL OR SOLVENTS SERVICING All other servicing with the exception of general user maintenance should be performed by an authorized service repre sentative Call 1 800 233 0268 Monday through Friday between the hours of 8 00 a m and 5 00 p m for the location of your nearest ser vice center LUBRICATION Precision bearings are sealed at the factory for life and do not require further lubrication STORAGE Store the Fan with these instructions in a clean and dry place 5084415
2. FUTURE REFERENCE SENERAL SAFETY INFORMATION Read all instructions before using Fan Make certain that the power source conforms to the electrical requirements of the Fan 3 Use this Fan only as described in this manual Any other use not recommended by the manufacturer may cause fire electrical shock or injury to persons 4 To reduce the risk of personal injury and electric shock the Fan should not be played with or placed where small children can reach it 5 Unplug power cord before servicing or moving the Fan WARNING DO NOT DEPEND UPON THE ON OFF SWITCH AS THE SOLE MEANS OF DISCONNECTING POWER WHEN IN STALLING OR SERVICING THE FAN ALWAYS UNPLUG THE POWER CORD 6 This Fan must NOT be used in potentially dangerous locations such as flammable explosive chemical laden or wet atmospheres 7 DO NOT use Fan in or near a window Rain may create an electrical hazard 8 Completely reassemble Fan according to instructions be fore reconnecting to power supply 9 The power cord is equipped with a three prong grounded plug that must be inserted into a matching receptacle Under no circumstances must the grounding prong be cut off the plug Where a two prong wall receptacle is encountered it must be replaced with a properly grounded three prong receptacle installed in accordance with the National Electrical Code NEC and all applicable local codes and ordinances This work must be done only by a qualified electrician
3. OF FIRE OR ELECTRIC SHOCK DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICES CAUTION BECAUSE OF THE SIZE AND WEIGHT OF THIS FAN MAKE SURE ALL PARTS ARE COMPLETELY AS SEMBLED ACCORDING TO INSTRUCTIONS FAILURE TO DO SO COULD RESULT IN FAN COMING APART DURING OPERATION AND OR PERSONAL INJURY SAVE THESE INSTRUCTIONS e e 5084415 TOOLS REQUIRED FOR ASSEMBLY e 2 Adjustable Wrenches min 3 4 open e Flathead Screwdriver e 3 16 Allen Wrench supplied in parts bag NOTE BECAUSE OF THE SIZE AND WEIGHT OF THIS FAN ASSEMBLY MAY REQUIRE TWO PEOPLE NOTE ALL HARDWARE REFERRED TO IN THE INSTRUCTIONS MAY BE FOUND IN THE SUPPLIED PARTS BAGS BASE ASSEMBLY Figure 1 1 Place Base on floor 2 Fit Mounting Flange through large hole in center of Base 3 Insert 4 3 8 16 X 1 Carriage Bolts through Mounting Flange and Base 4 Tilt Base and secure one Carriage Bolt at a time by first putting ona 3 8 Split Lockwasher and then a 3 8 16 Hex Nut DO NOT FULLY TIGHTENAT THIS TIME Repeat above procedure with remaining Bolts 5 GO BACK AND FULLY TIGHTEN each Hex Nut so that the Flange is securely assembled to the Base 6 Thread the 3 8 16 X 3 4 Set Screw into the Mounting Flange Carraige Bolts 4 Tart i Eebeeddes ML Set Screw Mounting Flange Base et a co cp Hex Nut 4 Split Lockwasher 4 _ aD Figure 1 New 3 04 MOTOR amp COLUMN ASSEMBLY F
4. IMPORTANT INSTRUCTIONS OPERATING MANUAL NOTES LIMITED WARRANTY AIRKING THREE YEAR LIMITED WARRANTY Products are warranted by AirKing to the original user against defects in workmanship or materials under normal use for three years on the motor and one year on all other parts after date of purchase Any part which is determined by AirKing to be detective in material or workmanship and returned to an authorized service location as AirKing designates shipping costs prepaid will be as the exclusive remedy repaired or replaced at AirKing s option For limited warranty claim procedures see PROMPT DISPOSITION below This limited warranty gives purchasers specific legal rights which vary from state to state LIMITATION OF LIABILITY To the extent allowable under applicable law AirKing s liability for consequential and incidental damages is expressly disclaimed AirKing s liability in all events is limited to and shall not exceed the purchase price WARRANTY DISCLAIMER AirKing has made a diligent effort to illustrate and describe the products in this literature accurately however such illustrations and descriptions are for the sole purpose of identification and do not express or imply a warranty the products are merchantable or fit a particular purpose or that the products will necessarily conform to the illustrations or descriptions Except as provided below no warranty or affirmation of fact expressed or implied other than as stat
5. e Screw is fully tightened and there is NO looseness between Column and Mounting Flange 5084415 GRILL AND BLADE ASSEMBLY Figures 3 and 4 1 Loosen knob tilt fan head back halfway retighten knob 2 Put rear grill onto motor Lining up the six holes in the grill with the six threaded holes in the mounting flange Install six 10 32 x 5 16 hex bolts through the grill into the mounting flange Securely tighten all bolts 3 Loosen knob and return head to a vertical postion Retighten knob 4 Push fan blade onto motor shaft center hub facing away from motor until it stops against shaft Align bolt head set screw with flat of the motor shaft TIGHTEN VERY SECURELY WITH AN ADJUSTABLE WRENCH Failure to securely tighten set screw could result in damage to the fan and or personal injury 5 Hold the front grill so that the name in the center is right side up and straight across Starting at the top Fasten front grill to rear grill by sliding the hooked wires on the front grill over the Outer most Ring on the rear grill Figure 4 Detail A 6 The bottom most Hooks will require the use of a flathead screw driver to complete assembly Stand behind Fan Slip the flat of the blade between the front and rear grills next to one of the unfastened hooks Figure 4 Detail B Pull screwdriver handle upwards towards the rear grill Slip the front grill hook over the rear grill outer ring with a push Repeat procedure with remaining Hooks Cauti
6. ed in LIMITED WARRANTY above is made or authorized by AirKing PRODUCT SUITABILITY Many states and locations have codes and regulations governing sales construction installation and or use of products for certain purposes which may vary from those in neighboring areas While AirKing attempts to assure that its products comply with such codes it cannot guarantee compliance and cannot be responsible for how the product is installed or used Before purchase and use of a product please review the product application and national and local codes and regulations and be sure that the product installation and use will comply with them Certain aspects of disclaimers are not applicable to consumer products e g a some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you b also some states do not allow limitations on how long an implied warranty lasts consequently the above limitation may not apply to you and c by law during the period of the Limited Warranty and implied warranties of merchantability or fitness for a particular purpose applicable to consumer products purchased by consumers may not be excluded or otherwise disclaimed PROMPT DISPOSITION AirKing will make a good faith effort for prompt correction or other adjustment with respect to any product which proves to be defective within limited warranty For any product believed to be d
7. efective within limited warranty first write or call dealer from whom product was purchased Dealer will give additional directions FOR PARTS Check package contents If parts are missing or replacement parts required please call our PARTS DEPARTMENT TOLL FREE AT 1 800 233 0268 MONDAY THROUGH FRIDAY BETWEEN THE HOURS OF 8 AM AND 4 PM EST PLEASE DO NOT RETURN PRODUCT TO PLACE OF PURCHASE Reference the type and style of product located on the underside of the product when you call FOR TECHNICAL ASSISTANCE and SERVICE CENTER LOCATIONS For any questions comments or the location of your nearest service center PLEASE CALL OUR TOLL FREE HOTLINE AT 1 800 233 0268 MONDAY THROUGH FRIDAY BETWEEN THE HOURS OF 8 AM AND 5 PM EST Please reference product name and model no when you call Appliance Service Dept e P O Box 569 Franklin TN 37064 PLEASE DO NOT SEND PRODUCT TO THIS LOCATION New 3 04 4 5084415 IMPORTANT INSTRUCTIONS OPERATING MANUAL Ventilation Products 24 30 OSCILLATING PEDESTAL FAN MODEL 9125 9135 9174 9175 24 30 NON OSCILLATING PEDESTAL FAN MODEL 9124 9130 9171 9170 READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE INSTALL OPERATE OR MAINTAIN THE PRODUCT DESCRIBED PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE RETAIN INSTRUCTIONS FOR
8. igure 2 Remove motor from foam place on a stable level surface on its side with the oscillation shaft facing upward 2 Slide flat section on Upper Tube of Column Assembly inside Motor Mounting Bracket Slot Align the 1 2 diameter Hole in the flat section on the Upper Tube of Column Assembly with the 1 2 diameter Hole in the Motor Mounting Bracket 3 Insert the 1 2 diameter x 1 long Hex Bolt 3 4 head through the Motor Bracket and the Upper Tube Assembly Place 1 2 di ameter Split Lockwasher then 1 2 diameter Nut 3 4 hex and tighten fully with 2 Adjustable Wrenches NOTE Secure these parts before continuing to the Column Base Assembly section 4 Insert one 1 4 20 x 1 3 8 Carriage Bolt through the Arc Shaped Slot in Motor Bracket and Hole in Upper Pipe of Column To Fasten Place one 1 4 Flatwasher one 1 4 Internal Tooth Lockwasher a second 1 4 Flat Washer and then tighten the Ad justment Knob over the remaining threads Non Oscillating Model COLUMN TO BASE ASSEMBLY 1 Rest Column and Head Assembly on floor next to the Base As sembly Tilt Base Assembly up on end Pick up Lower Pipe of Column and insert bottom of Pipe into the Mounting Flange 2 Tilt entire Assembly base and head upright Confirm that the column is fully seated in Mounting Flange Insert and securely tighten the 3 8 16 x 3 4 Allen Set Screw in Mounting Flange with the Allen Wrench supplied in parts bag Make sur
9. on Be careful not to bend any wires on grills or pinch your hands during assembly 7 Attach pull cord to pull chain Fan assembly is now complete Re fer to sections below for correct operating instructions and main tenance Oscillating Model Detail A Top Hooks Z Detail B Figure 3 Figure 4 Bottom Hooks Non Oscillating Model Detail A Top Hooks a Detail B Figure 4 Bottom Hooks Figure 3 New 3 04 OPERATING INSTRUCTIONS 1 TO OPERATE Plug cord into a grounded 120V 60 Hz outlet Select desired operating speed with pull cord on the rear of the motor First pull High Second pull Medium Third pull Low Fourth pull OFF NOTE This fan is very heavy Failure to securely hold onto head assembly while adjusting head height or head angle could result in personal injury 2 TO ADJUST HEAD ANGLE While holding head firmly loosen knob under motor turn counterclockwise Tilt head to desired position FIRMLY retighten knob under motor 3 TO ADJUST HEAD HEIGHT While holding upper column firmly loosen set screw on column collar turn counterclockwise Raise or lower head to desired position FIRMLY retighten set screw NOTE Motor Head Adjustment Knob On Off Pull Cord and Set Screw Placement have the same location on oscillating or non oscialling models NOTE FOR OSCILLATING MODELS FAN IS SHIPPED WITH 90 OSCILLATION ANGLE FOR
10. using copper wire only WARNING USE OF A THREE PRONG TO TWO PRONG ADAPTER IS NOT RECOMMENDED IMPROPER CONNECTION MAY CREATE THE RISK OF ELECTROCUTION USE OF SUCH ADAPTERS ARE NOT PERMITTED IN CANADA New 3 04 10 Where possible avoid the use of extension cords If they must be used minimize the risk of overheating by ensuring that they are UL listed Never use a single extension cord to operate more than one Fan Do not operate any Fan with a damaged cord or plug or after the Fan malfunctions has been dropped or damaged in any manner Return Fan to authorized service facility for examination electrical or mechanical adjustment or repair 12 Do not insert or allow fingers or foreign objects to enter any ventilation or exhaust opening as it may cause an electric shock or fire or damage the Fan Do not block or tamper with the Fan in any manner while it is in operation 13 Always place the Fan on a stable flat level surface when operating to avoid the chance of the Fan overturning Locate the Power Cord so the Fan or other objects are not resting on it Do not run Power Cord under carpeting Do not cover Power Cord with throw rugs runners or the like Arrange Power Cord away from room traffic and where it will not be tripped over 14 This Fan is not intended for use in wet or damp locations Never locate a Fan where it may fall into a bathtub or other water container 15 Do not use Fan outdoors WARNING REDUCETHE RISK