Home
GT1045-QSBD, GT1040-QBBD GT10 General
Contents
1. while the input of the touch switch s remains active This may confuse an operator in thinking that the GOT is in screensaver mode who then tries to release the GOT from this mode by touching the display section which may cause a touch switch to operate STARTUP MAINTENANCE PRECAUTIONS GT Designer3 Version1 Screen Design Manual For GOT1000 Series tion for drawi dt itti Fundamentals 1 2 2 2 operation for drawing and transmitting data to GOT1000 series WARNING e When power is on do not touch the terminals Doing so can cause an electric shock or malfunction e Connect the battery correctly Describes methods of the GT Designers installation operation basic SH O80866ENG 1D7MB9 sold separately 1 Do not discharge disassemble heat short solder or throw the battery into the fire DESIGN PRECAUTIONS CAUTION Incorrect handling may cause the battery to generate heat burst or take fire Sandara Renmark GT Designers Version ee f resulting in injuries or fires Em Compliance with all relevant aspects of the Screen Design Manual Describes specifications and settings S H 080867ENG Replace GT11 50BAT with CR2450HR by Hitachi Maxell only EN61131 2 2007 standard Radiated Emissions ForGOTT000 Series Of the object tunetions used in GT ADI7MC S e Do not bundle the control and communication cables with main circuit power or other wiring Run the above cables separately from such wiring and kee
2. in the environment of oil or chemicals use the protective cover for oil Failure to do so may cause failure or malfunction due to the oil or chemical entering into the GOT Be sure to shut off all phases of the external power supply used by the system before wiring Failure to do so may result in an electric shock product damage or malfunctions Use 60 to 75 C 16AWG 1 3mm maximum copper conductors only Torque from 0 22 Nem to 0 25 Nem Please make sure to ground FG terminal of the GOT power supply section by applying 100 or less which is used exclusively for the GOT Not doing so may cause an electric shock or malfunction Correctly wire the GOT power supply section after confirming the rated voltage and terminal arrangement of the product Not doing so can cause a fire or failure Tighten the terminal screws of the GOT power supply section in the specified torque range Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or the GOT Exercise care to avoid foreign matter such as chips and wire offcuts entering the GOT Not doing so can cause a fire failure or malfunction WIRING PRECAUTIONS c AUTION e Plug the communication cable into the connector of the connected unit and tighten the mounting and terminal screws in the specified torque range Undertightening can cause a short circuit or malfunction Overtightening can cause a short c
3. the display response becomes slow due to the characteristics of the STN liquid crystal Please check the display response in advance for using this product e When the same screen is displayed for a long time an incidental color or partial discoloration is generated on the screen due to heat damage and it may not disappear To prevent heat damage the screen saver function is effective For details on the screen saver function refer to the following GT10 User s Manual 2 ROM in which new data can be written without deleting the written data 3 Note that this does not guarantee all users operation environment In addition the product may not be used in environments under exposition of oil or chemicals for a long period of time or in environments filled with oil mist 4 Set the terminating resistor selector switch of the GOT in accordance with the connection type when adopting GOT multidrop connection For details of GOT multidrop connection refer to the following GOT1000 Series Connection Manual 1 3 Power Supply Specifications For details on power supply wiring such as the allowable cable size and tightening torque refer to the additional manual GT10 User s Manual This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights Specmeations which m
4. 8P 250mm 100mm 9 84inch 3 93inch S cor units Programmable controller ele Comes eri Added by user Added by user 2 General notes on Power supply The GT1045 QSBD and GT1040 QBBD unit requires an additional ferrite filter to be attached to the 24V DC power supply cables The filter should be attached in a similar manner as shown in the figure opposite i e the power cables are wrapped around the filter However as with all EMC situations the more correctly applied precautions the better the systems Electro magnetic Compatibility Up to The ferrite recommended is a TDK ZCAT3035 1330 75mm 2 or similar The ferrite should be placed as near to 2 95inch the 24V DC terminals of the GT1045 QSBD and y4 _ GT1040 QBBD as possible which should be within 75mm of the GOT terminal INPUT 2AVDC FG a E Associated Manuals The following manuals are relevant to this product When these loose manuals are required please consult with our local distributor Manual name Contents stica bns Model Code Describes the GT10 hardware relevant content such as part names external dimensions mounting power supply wiring specifications and introduction to option devices GT10 User s Manual sold separately JY997D24701 09R819 GOT1000 Series Connection Manual 1 3 2 3 3 3 Describes system configurations of the connection method applicable to SH 080532ENG GOT1000 series and cable creation 1
5. D7M26 method Compliance with EC directive CE Marking This note does not guarantee that an entire mechanical module produced in accordance with the contents of this note will comply with the following standards Compliance to EMC directive for the entire mechanical module should be checked by the user manufacturer For more details please contact the local Mitsubishi Electric sales site monitoring on the GOT communication between the GOT and PLC CPU is sold separately 1 suspended and the GOT becomes inoperative A system where the GOT is used should be configured to perform any significant operation to the system by using the switches of a device other than the GOT on the assumption that a GOT communication fault will occur TEST OPERATION PRECAUTIONS GT Designer2 Version2 Basic Operation Data Transfer Manual For GOT1000 Series Describes methods of the GT Designer2 installation operation basic SH O80529ENG operation for drawing and transmitting 1D7M24 WARNING e Before performing the test operations of the user creation monitor screen such as Not doing so can cause an accident due to false output or malfunction Do not use the GOT as the warning device that may cause a serious accident An independent and redundant hardware or mechanical interlock is required to configure the device that displays and outputs serious warning Failure to observe this instruction may result in an accident due to incorrect outpu
6. For details of a PLC to be connected refer to the PLC user s manual respectively Bundled Items Explanation of the GOT model name GT1040 x xxx L Power type Panel color type Display device type S STN color B STN monochrome blue white Model Name Remark GT1045 QSBD GT1040 QBBD GOT main unit D 24VDC The maintenance supplies below are packed with the product B Black Maintenance Supplies Quantity Panel Mounting Bracket with M4 x 20 screws 4 Panel Mounting Packing 1 Resolution peal evr GT10 General Description This manual 1 Display color type ee colors supported 0 Monochrome black white Screen size type 5 5 7 GOT1000 series GT10 1 Specifications 1 1 General Specifications Specifications GT1045 QSBD GT1040 QBBD Item Operating ambient Display section 0 to 50 C temperature Other than display section 0 to 55 C When mounted horizontally 0 to 50 C When mounted vertically 20 to 60 C 10 to 90 RH non condensing The wet bulb temperature is 39 C or less Storage ambient temperature Operating ambient humidity Storage ambient humidity 10 to 90 RH non condensing The wet bulb temperature is 39 C or less Conforms to JIS B3502 IEC 61131 2 147m s2 11 ms Sine half wave pulse 3 times each in the X Y and Z directions Sweep Count Conforms to JIS Vibration resistance B3502 and IEC61131 2 Shock resistance Must be free of lamp black co
7. General Description This manual 1 Display color type 5 256 colors supported Backup target Clock data alarm history and recipe data 0 Monochrome black white Approx 5 years Operating ambient temperature of 25 Buzzer output a buzzer that sounds o cea when touch keys are pressed Single tone LONG SHORT OFF adjustable GOT1000 series GT10 Screen size type 5 5 7 Environmental protective structure s Equivalent to IP67 JEM1030 front section External dimensions W139 5 47 x H112 4 4 x D41 1 61 mm inch Excluding mounting fixtures Horizontal format 1 Specifications RS 422 485 1ch 1 1 General Specifications Transmission speed 115 200 57 600 38 400 19 200 9 600 4 800bps e RS 422 485 Connector shape D sub 9 pin Female Item aaea a Application PLC communication GT1045 QSBD GT1040 QBBD Terminating resistor Open 1100 330Q Switched by terminating resistor selector switch At factory shipment 3309 US Operating ambient Display section 0 to 50 C RS 232 dch temperature Other than display section 0 to 55 C When mounted horizontally 0 to 50 C When mounted vertically ae RS 232 Ui aaa sane hs tia i a A Storage ambient temperature 20 to 60 C Application PLC communication bar code reader connection PC communication Project data upload download OS installation transparent function USB Full Speed 12Mbps 1ch B Connector shape Mini B Application PC communication Project data upload download OS ins
8. JY997D32901K MITSUBISHI ELECTRIC JAPANESE ENGLISH GT1045 QSBD GT1040 QBBD GT10 General Description GRAPHIC OPERATION TERMINAL Manual Number JY997D32901K This manual describes the specifications of the product Before use read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions And store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user Registration The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company Effective April 2015 Specifications are subject to change without notice 2008 MITSUBISHI ELECTRIC CORPORATION Safety Precaution Read these precautions before using Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this product In this manual the safety precautions are ranked as WARNING and CAUTION Indicates that incorrect handling may cause hazardous NWARNING conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous conditions resulting in medium or slight personal injury CAUTION or p
9. ault When unplugging the cable connected to the unit do not hold and pull the cable portion Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault Do not drop or apply any impact to the battery If any impact has been applied discard the battery and never use it The battery may be damaged by the drop or impact Before touching the unit always touch grounded metal etc to discharge static electricity from human body etc Not doing so can cause the unit to fail malfunction Replace battery with GT11 50BAT by Mitsubishi electric Co only Use of another battery may present a risk of fire or explosion Dispose of used battery promptly Keep away from children Do not disassemble and do not dispose of in fire e When disposing of the product handle it as industrial waste e When disposing of batteries separate them from other wastes according to the local regulations For details of the battery directive in EU member states refer GOT User s Manual TRANSPORTATION PRECAUTIONS CAUTION e When transporting lithium batteries make sure to treat them based on the transport regulations Refer to User s Manual for details of the regurated models Before transporting the GOT turn the GOT power on and check that the battery voltage status is normal on the Time setting amp display screen utilities screen In addition confirm that the adequate battery life remains on the
10. ay occur as a result of using the contents noted in this manual GT1045 QSBD GT1040 QBBD Item Warranty Input power supply voltage 24VDC 10 15 Mitsubishi will not be held liable for damage caused by factors found not to be Fuse built in not 1 0A the cause of Mitsubishi opportunity loss or lost profits caused by faults in the exchangeable Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life Power consumption At backlight off Inrush current 3 6W 150mA 24VDC or less 2 9W 120mA 24VDC or less 15A or less 26 4VDC 2ms Permissible instantaneous power failure time 1 Within 5ms Noise voltage 1000Vp p Noise width 1s by noise Noise immunity simulator of 30 to 100Hz noise frequency e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsaf
11. batterie risque d exploser si elle n est pas manipul e correctement Ne pas la recharger la d monter ni la jeter au feu Programmable controllers Equipment requirement and tests Compliance with all relevant aspects of the standard ESD RF electromagnetic field EFTB Surge RF conducted disturbances and Power 1 Stored in the GT Works 2 GT Designer2 GT Works3 GT Designer3 in PDF frequency magnetic field format For details of a PLC to be connected refer to the PLC user s manual respectively EMS For more details please contact the local Mitsubishi Electric sales site Bundled Items Specifications GT1045 QSBD Explanation of the GOT model name GT1040 x Item Model Name Remark GT1040 QBBD GT1045 QSBD GOT main unit a Power type D 24VDC C drive Flash memory ROM Internal for storing project data 3M bytes or less and OS The maintenance supplies below are packed with the product GT1040 QBBD eee KASE bi RIOsuer Panel color type B Black Memory Life Number of write times 100 000 times Maintenance Supplies Quantity Display device type S STN color SRAM Internal for storing alarm history recipe data and time action setting value ESIN monochrome blue white rar Panel Mounting Bracket with M4 x 20 screws 4 Battery GT11 SOBAT lithium battery Panel Mounting Packing 1 Resolution Q 320 x 240 QVGA Type Magnesium maganese dioxide lithium primary battery GT10
12. cations Specifications GT1045 QSBD GT1040 QBBD Type STN color liquid crystal STN monochrome white blue liquid crystal 4 Screen size 7 320 x 240 dots Horizontal format W96 3 77 x H72 2 83 mm inch Horizontal format 16 dot standard font 40 characters x 15 lines 12 dot standard font 53 characters x 20 lines Horizontal format 256 colors Monochrome white blue 16 scales Left Right 50 degrees Top 40 degrees Bottom 70 degrees Left Right 45 degrees Top 20 degrees Bottom 40 degrees Horizontal format Horizontal format 16 level adjustment 150 cd m2 300 cd m2 Life Approx 50 000h Time for display intensity to become 1 5 at operating ambient temperature of 25 C Item Resolution Display size Display character Display section Display color Display angle Contrast adjustment Intensity of LCD only Backlight LED Backlight off screen saving time can be set Number of touch keys Maximum 50 keys screen Matrix resistive film touch panel Key size Minimum 16 x 16 dots per key Touch Simultaneous pressing of two panel or more areas Enable 2 point press 1 million times or more operating force 0 98N max Specifications GT1045 QSBD Flash memory ROM Internal for storing project data 3M bytes or less and OS Item GT1040 QBBD C drive Memory Life Number of write times 100 000 times D drive SRAM Internal for storing alarm history recipe data and time act
13. e functions in the system Dielectric withstand voltage 500VAC for 1 minute across power supply terminals and earth 10MQ or larger by insulation resistance tester across Insulation resistance power supply terminals and earth The GOT continues to operate even upon 5ms or shorter instantaneous power failure The GOT stops operating if there is extended power failure or voltage drop while it automatically resumes operation as soon as the power is restored MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JY997D32901K MITSUBISHI ELECTRIC JAPANESE ENGLISH GT1045 QSBD GT1040 QBBD GT10 General Description GRAPHIC OPERATION TERMINAL Manual Number JY997D32901K This manual describes the specifications of the product Before use read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions And store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user Registration The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company Effective April 2015 Specifications are subject to change without notice 2008 MITSUBISHI ELECTRIC CORPORATION Safety Precaution Read thes
14. e precautions before using Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this product In this manual the safety precautions are ranked as WARNING and CAUTION Indicates that incorrect handling may cause hazardous NWARNING conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous conditions resulting in medium or slight personal injury CAUTION or physical damage Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to follow the directions for usage MOUNTING PRECAUTIONS WARNING e Be sure to shut off all phases of the external power supply used by the system before mounting or removing the GOT to from the panel Not doing so can cause the unit to fail or malfunction e When installing the battery wear an earth band etc to avoid the static electricity The static electricity can cause the unit to fail or malfunction MOUNTING PRECAUTIONS CAUTION e Use the GOT in the environment that satisfies the general specifications described in this manual Not doing so can cause an electric shock fire malfunction or product damage or deterioration Do not connect directly to line voltage Line voltage must be supp
15. errite recommended is a TDK ZCAT3035 1330 75mm 2 or similar The ferrite should be placed as near to 2 95inch the 24V DC terminals of the GT1045 QSBD and y4 _ GT1040 QBBD as possible which should be within 75mm of the GOT terminal INPUT 2AVDC FG a E Associated Manuals The following manuals are relevant to this product When these loose manuals are required please consult with our local distributor Manual Number Describes the GT10 hardware Transporting the GOT with the low battery voltage or the battery the reached relevant content such as part names attery life may unstabilize the backup data unstable during transportation external dimensions mounting power DESIGN PRECAUTIONS N WARNING battery lif tabilize the backup data unstable during t rtati arson aa dimensi ing p OR WIRING PRECAUTIONS CAUTION Make sure to transport the GOT main unit and or relevant unit s in the manner p y supply wiring specifications and they will not be exposed to the impact exceeding the impact resistance described in the general specifications of this manual as they are precision devices Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation e Some failures of the GOT or cable may keep the outputs on or off introduction to option devices An external monitoring circuit should be provided to check for output signals which may lead to a serious accident Not doing so can cause a
16. f GOT multidrop connection refer to the following GOT1000 Series Connection Manual 1 3 Power Supply Specifications For details on power supply wiring such as the allowable cable size and tightening torque refer to the additional manual GT10 User s Manual Operating ambient humidity 10 to 90 RH non condensing The wet bulb temperature is 39 C or less Storage ambient humidity 10 to 90 RH non condensing The wet bulb temperature is 39 C or less Sweep Count Conforms to JIS Vibration resistance B3502 and IEC61131 2 Shock resistance Must be free of lamp black corrosive gas flammable gas or excessive amount of electroconductive dust particles and must be no direct sunlight Same as for saving 2000 m 6562 ft max Operating atmosphere Operating altitude Installation location Inside control panel Overvoltage category 2 Pollution degree s 2 or less Cooling method Self cooling Grounding Class D grounding 100Q or less To be connected to the panel when grounding is not possible 1 Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude Om Oft Failure to observe this instruction may cause a malfunction When the air inside the control panel is purged by pressurization the surface sheet may be lifted by high pressure As a result the touch panel may be difficult to press and the sheet may be peeled off 2 This indicates the section of the power supp
17. ftware package GT Designer2 Version 2 90U or later GT Designer3 Version 1 01B or later 1 Bright dots always lit and dark dots unlit may appear on a liquid crystal display panel It is impossible to completely avoid this symptom as the liquid crystal display comprises of a great number of display elements Flickers may be observed depending on the display color Please note that these dots appear due to its characteristic and are not caused by product defect e Flickers and partial discoloration may be generated on the liquid crystal display panel due to the display contents or the contrast adjustment However please note that these phenomena appear due to its characteristic and are not caused by product defect There is a difference in the display brightness and the color tones between liquid crystal display panels When using multiple liquid crystal display panels please note that there is an individual difference between them e A crosstalk shadow as an extension of the display may appear on the liquid crystal display panel Please note that it appears due to its characteristic e When the display section is seen from the outside of the display angle the display color seems like it has changed Please note that it is due to its characteristic Please note that the response time brightness and color of the liquid crystal display panel may vary depending on the usage environmental temperature Especially in the low temperature environment
18. hem ll or less e A crosstalk shadow as an extension of the display may appear on the liquid crystal display panel Please note that it appears due to its characteristic e When the display section is seen from the outside of the display angle the display color seems like it has changed Please note that it is due to its characteristic Please note that the response time brightness and color of the liquid crystal display panel may vary depending on the usage environmental temperature Especially in the low temperature environment the display response becomes slow due to the characteristics of the STN liquid crystal Please check the display response in advance for using this product e When the same screen is displayed for a long time an incidental color or partial discoloration is generated on the screen due to heat damage and it may not disappear To prevent heat damage the screen saver function is effective For details on the screen saver function refer to the following GT10 User s Manual ROM in which new data can be written without deleting the written data 3 Note that this does not guarantee all users operation environment In addition the product may not be used in environments under exposition of oil or chemicals for a long period of time or in environments filled with oil mist 4 Set the terminating resistor selector switch of the GOT in accordance with the connection type when adopting GOT multidrop connection For details o
19. hysical damage Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to follow the directions for usage NWARNING e Some failures of the GOT or cable may keep the outputs on or off An external monitoring circuit should be provided to check for output signals which may lead to a serious accident Not doing so can cause an accident due to false output or malfunction If a communication fault including cable disconnection occurs during DESIGN PRECAUTIONS MOUNTING PRECAUTIONS WARNING e Be sure to shut off all phases of the external power supply used by the system before mounting or removing the GOT to from the panel Not doing so can cause the unit to fail or malfunction e When installing the battery wear an earth band etc to avoid the static electricity STARTUP MAINTENANCE PRECAUTIONS WARNING e Before starting cleaning or terminal screw retightening always switch off the power externally in all phases Not switching the power off in all phases can cause a unit failure or malfunction Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit Notes for compliance to EMC regulation 1 General notes on the use of communication cables Any device which utilizes a data communication function is susceptible to the wider effects of local EMC noise Theref
20. i products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life Display character 16 dot standard font 40 characters x 15 lines 12 dot standard font 53 characters x 20 lines Horizontal format 256 colors Monochrome white blue 16 scales Left Right 50 degrees Top 40 degrees Bottom 70 degrees Left Right 45 degrees Top 20 degrees Bottom 40 degrees Horizontal format Horizontal format 16 level adjustment 150 cd m2 300 cd m2 Life Approx 50 000h Time for display intensity to become 1 5 at operating ambient temperature of 25 C Display Power consumption section Display color At backlight off Inrush current 3 6W 150mA 24VDC or less 2 9W 120mA 24VDC or less Display angle 15A or less 26 4VDC 2ms Permissible instantaneous power failure time 1 Within 5ms Contrast adjustment Intensity of LCD only Noise voltage 1000Vp p Noise width 1us by noise Doles iy simulator of 30 to 100Hz noise frequency e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with M
21. ion setting value GT11 50BAT lithium battery Type Magnesium maganese dioxide lithium primary battery Backup target Clock data alarm history and recipe data Approx 5 years Operating ambient temperature of 25 Buzzer output a buzzer that sounds o 7 when touch keys are pressed Single tone LONG SHORT OFF adjustable Battery Environmental protective structure 3 Equivalent to IP67 JEM1030 front section External dimensions W139 5 47 x H112 4 4 x D41 1 61 mm inch Excluding mounting fixtures Horizontal format RS 422 485 1ch Transmission speed 115 200 57 600 38 400 19 200 9 600 4 800bps RS 422 485 Connector shape D sub 9 pin Female Application PLC communication Terminating resistor Open 1100 330Q Switched by terminating resistor selector switch At factory shipment 3309 RS 232 1ch Built in Transmission speed 115 200 57 600 38 400 19 200 9 600 4 800bps interface RS 232 Connector shape D sub 9 pin Male Application PLC communication bar code reader connection PC communication Project data upload download OS installation transparent function USB Full Speed 12Mbps 1ch USB Connector shape Mini B Application PC communication Project data upload download OS installation transparent function GT10 50FMB For connecting GT10 50FMB memory board Panel cutting dimensions W130 5 11 x H103 4 05 mm inch Horizontal format Weight 0 45kg Excluding mounting fixtures Compatible so
22. ircuit or malfunction due to the damage of the screws or unit STARTUP MAINTENANCE PRECAUTIONS TRANSPORTATION PRECAUTIONS CAUTION Do not disassemble or modify the unit Doing so can cause a failure malfunction injury or fire Do not touch the conductive and electronic parts of the unit directly Doing so can cause a unit malfunction or failure The cables connected to the unit must be run in ducts or clamped Not doing so can cause the unit or cable to be damaged due to the dangling motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault When unplugging the cable connected to the unit do not hold and pull the cable portion Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault Do not drop or apply any impact to the battery If any impact has been applied discard the battery and never use it The battery may be damaged by the drop or impact Before touching the unit always touch grounded metal etc to discharge static electricity from human body etc Not doing so can cause the unit to fail malfunction Replace battery with GT11 50BAT by Mitsubishi electric Co only Use of another battery may present a risk of fire or explosion Dispose of used battery promptly Keep away from children Do not disassemble and do not dispose of in fire When disposing of the product handle it as industrial waste When disposing
23. itsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Dielectric withstand 500VAC for 1 minute across power supply terminals Backlight voltage and earth LED Backlight off screen saving time can be set Number of touch keys Maximum 50 keys screen Matrix resistive film touch panel 10MQ or larger by insulation resistance tester across MsulaiomTesistante power supply terminals and earth Key size Minimum 16 x 16 dots per key Touch Simultaneous pressing of two panel or more areas Enable 1 The GOT continues to operate even upon 5ms or shorter instantaneous power failure The GOT stops operating if there is extended power failure or voltage drop while it automatically resumes operation as soon as the power is restored 2 point press MITSUBISHI ELECTRIC CORPORATION Life 1 million times or more operating force 0 98N max HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN
24. lied by a suitable approved isolating transformer having short circuit capacity not exceeding 100VA maximum 26 2VDC max Ne pas connecter directement a la tension de la ligne La tension de la ligne doit tre fournie par un transformateur d isolement appropri et approuv ayant une capacit de court circuit ne d passant pas 100 VA maximum 26 2VDC max When mounting the GOT to the control panel tighten the mounting screws in the specified torque range Undertightening can cause the GOT to drop short circuit or malfunction and deteriorate the waterproof effect and oilproof effect Overtightening can cause a drop short circuit or malfunction due to the damage of the screws or the GOT and deteriorate the waterproof effect and oilproof effect due to distortion of the protective cover for oil GOT or panel When using the GOT in the environment of oil or chemicals use the protective cover for oil Failure to do so may cause failure or malfunction due to the oil or chemical entering into the GOT Be sure to shut off all phases of the external power supply used by the system before wiring Failure to do so may result in an electric shock product damage or malfunctions Use 60 to 75 C 16AWG 1 3mm maximum copper conductors only Torque from 0 22 Nem to 0 25 Nem Please make sure to ground FG terminal of the GOT power supply section by applying 100 or less which is used exclusively for the GOT Not doing so may cause an electric shock o
25. ly to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within the premises 9 Category II applies to equipment for which electrical power is supplied from fixed facilities The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V 3 This index indicates the degree to which conductive material is generated in the environment where the equipment is used In pollution degree 2 only non conductive pollution occurs but temporary conductivity may be produced due to condensation 1 2 Performance Specifications Specifications GT1045 QSBD GT1040 QBBD Type STN color liquid crystal STN monochrome white blue liquid crystal item 4 This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation Item cannot be held responsible for any problems involving industrial property rights speciicalous which may occur as a result of using the contents noted in this manual Screen size 7 GT1040 QBBD 3 3 Warranty Resolution 320 x 240 dots Horizontal format Input power Supp Voltage AAVDC tials Mitsubishi will not be held liable for damage caused by factors found not to be Display size W96 3 77 x H72 2 83 mm inch Horizontal format Fuse built in not 1 0A the cause of Mitsubishi opportunity loss or lost profits caused by faults in the exchangeable Mitsubish
26. n accident due to false output or malfunction If a communication fault including cable disconnection occurs during monitoring on the GOT communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative A system where the GOT is used should be configured to perform any significant operation to the system by using the switches of a device other than the GOT on the assumption that a GOT communication fault will occur Not doing so can cause an accident due to false output or malfunction Do not use the GOT as the warning device that may cause a serious accident An independent and redundant hardware or mechanical interlock is required to configure the device that displays and outputs serious warning Failure to observe this instruction may result in an accident due to incorrect output or malfunction Incorrect operation of the touch switch s may lead to a serious accident if the GOT backlight is gone out When the GOT backlight goes out causes the monitor screen to appear blank while the input of the touch switch s remains active This may confuse an operator in thinking that the GOT is in screensaver mode who then tries to release the GOT from this mode by touching the display section which may cause a touch switch to operate e Plug the communication cable into the connector of the connected unit and tighten the mounting and terminal screws in the specified torque range Undertightening can cause a short circ
27. of batteries separate them from other wastes according to the local regulations For details of the battery directive in EU member states refer GOT User s Manual CAUTION When transporting lithium batteries make sure to treat them based on the transport regulations Refer to User s Manual for details of the regurated models Before transporting the GOT turn the GOT power on and check that the battery voltage status is normal on the Time setting amp display screen utilities screen In addition confirm that the adequate battery life remains on the rating plate Transporting the GOT with the low battery voltage or the battery the reached battery life may unstabilize the backup data unstable during transportation Make sure to transport the GOT main unit and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of this manual as they are precision devices Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation GOT Unit Existing Cables User Made Cables Those cables need to be independently GT1045 QSBD GT01 C30R4 8P tested by the user to demonstrate EMC and modified as compatibility when they are used with GT1040 QBBD shown in EX 1 Mitsubishi GOT unit and FX3U Programmable Controllers Ex 1 F Ferrite core Ex NEC TOKIN ESD R 17S TDK ZCAT3035 1330 or similar GT01 C30R4
28. ore when installing any communication cables care should always be taken with the routing and location of those cables The GOT units identified on the previous chapter are compliant with the EMC requirement when the following communication cables are used The static electricity can cause the unit to fail or malfunction MOUNTING PRECAUTIONS CAUTION e Use the GOT in the environment that satisfies the general specifications described in this manual Not doing so can cause an electric shock fire malfunction or product damage or deterioration Do not connect directly to line voltage Line voltage must be supplied by a suitable approved isolating transformer having short circuit capacity not exceeding 100VA maximum 26 2VDC max Ne pas connecter directement a la tension de la ligne La tension de la ligne doit tre fournie par un transformateur d isolement appropri et approuv ayant une capacit de court circuit ne d passant pas 100 VA maximum 26 2VDC max When mounting the GOT to the control panel tighten the mounting screws in the specified torque range Undertightening can cause the GOT to drop short circuit or malfunction and deteriorate the waterproof effect and oilproof effect Overtightening can cause a drop short circuit or malfunction due to the damage of the screws or the GOT and deteriorate the waterproof effect and oilproof effect due to distortion of the protective cover for oil GOT or panel When using the GOT
29. p them a minimum of 100mm 3 94in apart Not doing so noise can cause a malfunction Do not press the GOT display section with a pointed material as a pen or driver Doing so can result in a damage or failure of the display section Before connecting to GOT turn ON the controller to enable the communication When the communication of controller is not available a communication error may occur in GOT Use of another battery may present a risk of fire or explosion See owner s manual for safety instructions Remplacez GT11 50BAT avec CR2450HR par Hitachi Maxell uniquement L utilisation d une autre batterie peut entra ner un risque d incendie ou d explosion Se reporter au manuel du propri taire pour connaitre les consignes de s curit Warning battery may explode if mistreated Do not recharge disassemble or dispose of in fire Avertissement la batterie risque d exploser si elle n est pas manipul e correctement Ne pas la recharger la d monter ni la jeter au feu Programmable controllers Equipment requirement and tests Compliance with all relevant aspects of the standard ESD RF electromagnetic field EFTB Surge RF conducted disturbances and Power frequency magnetic field EMS For more details please contact the local Mitsubishi Electric sales site Functions 1 2 2 2 sold separately 1 1 Stored in the GT Works 2 GT Designer2 GT Works3 GT Designer3 in PDF format Designer3
30. r malfunction Correctly wire the GOT power supply section after confirming the rated voltage and terminal arrangement of the product Not doing so can cause a fire or failure Tighten the terminal screws of the GOT power supply section in the specified torque range Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or the GOT Exercise care to avoid foreign matter such as chips and wire offcuts entering the GOT Not doing so can cause a fire failure or malfunction STARTUP MAINTENANCE PRECAUTIONS WARNING Before starting cleaning or terminal screw retightening always switch off the power externally in all phases Not switching the power off in all phases can cause a unit failure or malfunction Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit STARTUP MAINTENANCE PRECAUTIONS CAUTION Do not disassemble or modify the unit Doing so can cause a failure malfunction injury or fire Do not touch the conductive and electronic parts of the unit directly Doing so can cause a unit malfunction or failure The cables connected to the unit must be run in ducts or clamped Not doing so can cause the unit or cable to be damaged due to the dangling motion or accidental pulling of the cables or can cause a malfunction due to a cable connection f
31. rating plate 2 General notes on Power supply Notes for compliance to EMC regulation 1 General notes on the use of communication cables Any device which utilizes a data communication function is susceptible to the wider effects of local EMC noise Therefore when installing any communication cables care should always be taken with the routing and location of those cables The GOT units identified on the previous chapter are compliant with the EMC requirement when the following communication cables are used GOT Unit Existing Cables User Made Cables Those cables need to be independently GT1045 QSBD GT01 C30R4 8P tested by the user to demonstrate EMC and modified as compatibility when they are used with GT1040 QBBD shown in EX 1 Mitsubishi GOT unit and FX3U Programmable Controllers Ex 1 F Ferrite core Ex NEC TOKIN ESD R 17S TDK ZCAT3035 1330 or similar GT01 C30R4 8P 250mm 100mm 9 84inch 3 93inch S cor units Programmable controller ele M Fr AF m Comes eri Added by user Added by user The GT1045 QSBD and GT1040 QBBD unit requires an additional ferrite filter to be attached to the 24V DC power supply cables The filter should be attached in a similar manner as shown in the figure opposite i e the power cables are wrapped around the filter However as with all EMC situations the more correctly applied precautions the better the systems Electro magnetic Compatibility Up to The f
32. rrosive gas flammable gas or excessive amount of electroconductive dust particles and must be no direct sunlight Same as for saving 2000 m 6562 ft max Operating atmosphere Operating altitude Installation location Inside control panel Overvoltage category 2 ll or less Pollution degree s 2 or less Cooling method Self cooling Grounding Class D grounding 100Q or less To be connected to the panel when grounding is not possible 1 Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude Om Oft Failure to observe this instruction may cause a malfunction When the air inside the control panel is purged by pressurization the surface sheet may be lifted by high pressure As a result the touch panel may be difficult to press and the sheet may be peeled off 2 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within the premises Category II applies to equipment for which electrical power is supplied from fixed facilities The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V 3 This index indicates the degree to which conductive material is generated in the environment where the equipment is used In pollution degree 2 only non conductive pollution occurs but temporary conductivity may be produced due to condensation 1 2 Performance Specifi
33. rst or take fire Standard Remak GT Designers Version spend resulting in injuries or fires Em Compliance with all relevant aspects of the Screen Design Manual Describes specifications and settings S H 080867ENG Replace GT11 50BAT with CR2450HR by Hitachi Maxell only EN61131 2 2007 standard Radiated Emissions ForGOTT000 Series Of the object tunetions used in GT ADI7MC S e Do not bundle the control and communication cables with main circuit power or other wiring Run the above cables separately from such wiring and keep them a minimum of 100mm 3 94in apart Not doing so noise can cause a malfunction Do not press the GOT display section with a pointed material as a pen or driver Doing so can result in a damage or failure of the display section Before connecting to GOT turn ON the controller to enable the communication When the communication of controller is not available a communication error may occur in GOT Functions 1 2 2 2 sold separately 1 Use of another battery may present a risk of fire or explosion Designer3 See owner s manual for safety instructions Remplacez GT11 50BAT avec CR2450HR par Hitachi Maxell uniquement L utilisation d une autre batterie peut entra ner un risque d incendie ou d explosion Se reporter au manuel du propri taire pour connaitre les consignes de s curit Warning battery may explode if mistreated Do not recharge disassemble or dispose of in fire Avertissement la
34. t or malfunction turning ON or OFF bit device changing the word device current value changing the settings or current values of the timer or counter read through the manual Attention e This product is designed for use in industrial applications sold separately 1 data to GOT1000 series carefully and make yourself familiar with the operation method During test operation never change the data of the devices which are used to perform significant operation for the system False output or malfunction can e Authorized Representative in the European Community Mitsubishi Electric Europe B V GT Designer2 Version2 Screen Design Manual For GOT1000 Series Describes specifications and settings of the object functions used in GT SH 080530ENG cause an accident Gothaer Str 8 40880 Ratingen Germany 1D7M25 Requirement for Compliance with EMC directive The following products have shown compliance through direct testing to the identified standards and design analysis forming a technical construction file to the European Directive for Electromagnetic Compatibility 2004 108 EC when used as directed by the appropriate documentation Type Programmable Controller Open Type Equipment 1 3 2 3 3 3 sold separately 1 Designer2 Incorrect operation of the touch switch s may lead to a serious accident if the GOT backlight is gone out When the GOT backlight goes out causes the monitor screen to appear blank
35. ta to GOT1000 series Describes methods of the GT Designer2 installation operation basic SH O80529ENG 1D7M24 WARNING Before performing the test operations of the user creation monitor screen such as turning ON or OFF bit device changing the word device current value changing the settings or current values of the timer or counter read through the manual carefully and make yourself familiar with the operation method During test operation never change the data of the devices which are used to perform significant operation for the system False output or malfunction can cause an accident sold separately 1 GT Designer2 Version2 Screen Design Manual Describes specifications and settings For GOT1000 Series of the object functions used in GT 1 3 2 3 3 3 Designer2 sold separately 1 SH 080530ENG 1D7M25 STARTUP MAINTENANCE PRECAUTIONS GT Designer3 Version1 Screen Design Manual For GOT1000 Series f ae Fundamentals 1 2 2 2 operation for drawing and transmitting data to GOT1000 series WARNING e When power is on do not touch the terminals Doing so can cause an electric shock or malfunction e Connect the battery correctly Do not discharge disassemble heat short solder or throw the battery into the fire Describes methods of the GT Designers installation operation basic SH O80866ENG 1D7MB9 sold separately 1 Incorrect handling may cause the battery to generate heat bu
36. tallation transparent function Under intermittent 5 to 9Hz ooo 8 5mm GT10 50FMB For connecting GT10 50FMB memory board vibration 9 to 150Hz 9 8m s2 fe 40 timesceaeh ine Panel cutting dimensions W130 5 11 x H103 4 05 mm inch Horizontal format inde continuous 5 to 9Hz Po 175m Y and Z directions Weight 0 45kg Excluding mounting fixtures vibration 9 to 150Hz 4 9m s2 fe Compatible software package GT Designer2 Version 2 90U or later GT Designer3 Version 1 01B or later Conforms to JIS B3502 IEC 61131 2 147m s2 11 ms Sine half wave pulse 3 times each in the X Y and Z directions Bright dots always lit and dark dots unlit may appear on a liquid crystal display panel It is impossible to completely avoid this symptom as the liquid crystal display comprises of a great number of display elements Flickers may be observed depending on the display color Please note that these dots appear due to its characteristic and are not caused by product defect e Flickers and partial discoloration may be generated on the liquid crystal display panel due to the display contents or the contrast adjustment However please note that these phenomena appear due to its characteristic and are not caused by product defect e There is a difference in the display brightness and the color tones between liquid crystal display panels When using multiple liquid crystal display panels please note that there is an individual difference between t
37. uit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit GOT1000 Series Describes system configurations of Connection Manual the connection method applicable to SH 080532ENG 1 3 2 3 3 3 GOT1000 series and cable creation 1D7M26 sold separately 1 method Compliance with EC directive CE Marking This note does not guarantee that an entire mechanical module produced in accordance with the contents of this note will comply with the following standards Compliance to EMC directive for the entire mechanical module should be checked by the user manufacturer For more details please contact the local Mitsubishi Electric sales site Attention e This product is designed for use in industrial applications e Authorized Representative in the European Community Mitsubishi Electric Europe B V Gothaer Str 8 40880 Ratingen Germany Requirement for Compliance with EMC directive The following products have shown compliance through direct testing to the identified standards and design analysis forming a technical construction file to the European Directive for Electromagnetic Compatibility 2004 108 EC when used as directed by the appropriate documentation Type Programmable Controller Open Type Equipment TEST OPERATION PRECAUTIONS GT Designer2 Version2 Basic Operation Data Transfer Manual ca For GOT 1000 Series operation for drawing and transmitting da