1. Before Device is installed Please read carefully the enclosed user manual before installation of the radio actuator in order to ensure an error free functioning ATTENTION only authorized technicians under consideration of the country specific installation guidelines norms may do works with 230 Volt mains power Prior to the assembly of the product the voltage network has to be switched off and ensured against re switching The product is permitted only for proper use as specified in the user manual Any kind of guarantee claim has to be forfeited if changes modifications or painting are undertaken The product must be checked for damages immediately after unpacking In the case of damages the product must not be operated in any case If a danger free operation of the equipment cannot be assured the voltage supply has to be interrupted immediately and the equipment has to be protected from unintended operation Installation Guidelines POWERING MODES There are two powering modes for the Fibaro Smoke Sensor By default it s powered by a factory included battery Alternatively it can work with a constant current after connecting a 12 24 VDC power supply to 12 24 and GND terminals see diagram no 3 Powering mode configuration is carried out automatically while sensor is being included into the Z Wave network When battery powered a Fibaro Smoke Sensor communicates with the Z Wave network main controller periodically Detected alarms
2. c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 8 assigned to the device status sending the BASIC SET default or ALARM control frame to the associated devices having detected fire max nodes in group 5 assigned to a TMP button and the malfunction alarm Alarm frame will be sent to the associated devices once tampering or malfunction are detected max nodes in group 5 reports the device status and allows for assigning single device only the main controller by default the device reports its status to the main controller max nodes in group 1 Configuration Parameters Z Wave products are supposed to work out of the box after inclusion however certain configuration can adapt the function better to user needs or unlock further enhanced features IMPORTANT Controllers may only allow to configure signed values In order to set values in the range 128 255 the value sent in the application shall be the desired value minus 256 For example to set a parameter to 200 it may be needed to set a value of 200 minus 256 minus 56 In case of two byte value the same logic applies Values greater than 32768 may needed to be given as negative values too Smoke alarm cancellation delay Parameter Number 1 Parameter Size 2 time period during which the Smoke Sensor will keep indicating the smoke alarm after smoke will have disappeared 0 no delay imme
3. are sent immediately but configuration parameters and associations settings only at specified wake up intervals or at a manual wake up B button triple click In DC powering mode configuration and associations parameters are sent when necessary and in addition sensor serves as a Z Wave signal repeater c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 2 c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 3 c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 4 c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 5 Switching to a constant current powering mode Exclude a sensor from the Z Wave network Disconnect the battery Install the constant power connecting terminal observing the diagram 2 Connect a constant current power source 12 24 VDC to 12 and GND terminals observing wiring diagram 1 5 Include Fibaro Smoke Sensor into the Z Wave network Poe NS B button and LED indicator Drill holes here Fibaro Smoke Sensor top view Constant current or alarm system hub connecting terminals installation Installation 1 Include the device into the Z Wave network see p l Note the inclusion process
4. between consecutive temperature reports 0 17280 0 Reports inactive Default 0 Temperature report hysteresis Parameter Number 12 Parameter Size 1 temperature change resulting in a temperature report 0 100 0 temperature change reporting inactive Default 20 Alarm broadcast Parameter Number 13 Parameter Size 1 defines the broadcast alarm setting alarm to all devices in direct range broadcast inactive Default 4 smoke alarm broadcast 1 st Association Group active tamper alarm broadcast 2 nd Association Group inactive smoke alarm broadcast 1 st Association Group inactive tamper alarm broadcast 2 nd Association Group active smoke alarm broadcast active 1 st association group tamper alarm broadcast 2 nd association group active c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 10 Temperature measurement compensation Parameter Number 73 Parameter Size 2 temperature value to be added to or deducted from the current measured temperature Value Description 64536 1000 Z Wave range test interval Parameter Number 80 Parameter Size 1 Time period between the consecutive Z Wave network range tests 0 17 0 Z Wave network range test inactive Default 1 Temperature alarm threshold Parameter Number 81 Parameter Size 1 Temperature value above which the temperature alarm is sent oo
5. 0 temperature alarm inactive 2 100 Default 54 Smoke Sensor sensitivity Parameter Number 82 Parameter Size 1 There are 3 levels of sensitivity to smoke presence Level 1 means the highest sensitivity Ve Dmenpten El HIGH Sensitivity MEDIUM Sensitivity Default LOW Sensitivity Black Box sensitivity level Parameter Number 83 Parameter Size 1 Parameter specifies temperature and smoke level after which the Black Box starts recording them Value Description 1 HIGH Sensitivity 2 MEDIUM Sensitivity 3 LOW Sensitivity c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 11 Malfunction alarm Parameter Number 84 Parameter Size 1 Time interval in which malfuntion alarm if detected is repeated using visual and acoustic alarms Value Description 130 127 Temperature alarm Parameter Number 85 Parameter Size 1 Time interval in which temperature alarm if detected is repeated using visual and acoustic alarms Value Description 130 127 5 means 500ms Lack of the Z Wave range alarm Parameter Number 86 Parameter Size 2 Time interval in which lack of the Z Wave network alarm if detected is repeated using visual and acoustic alarms 1 17280 360 means 30min Default 360 Low battery alarm Parameter Number 87 Parameter Size 2 Time interval in which low battery alarm if detected is repeated u
6. Fibaro Smoke Sensor By default the detector is set to the middle sensitivity level Sensitivity level depends on the parameter 82 settings DETECTING FIRE THROUGH TEMPERATURE ALARM Apart from detecting smoke presence Fibaro Smoke Sensor can detect fire by recording a rapid temperature rise Temperature alarm threshold is user defined parameter 81 Temperature alarm is signaled by the LED signaling diode blinking red and an intermittent sound signal Wakeup Intervals how to communicate with the device c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 7 This device is battery operated and turned into deep sleep state most of the time to save battery life time Communication with the device is limited In order to communicate with the device a static controller C is needed in the network This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state Without such a controller communication may become impossible and or the battery life time is significantly decreased This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification The controller can then empty the mailbox Therefore the device needs to be configured with the desired wakeup interval and the node ID of the controller If the device was included by a static controller this co
7. Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 13 Controller is a Z Wave device with capabilities to manage the network Controllers are typically Gateways Remote Controls or battery operated wall controllers Slave is a Z Wave device without capabilities to manage the network Slaves can be sensors actuators and even remote controls Primary Controller is the central organizer of the network It must be a controller There can be only one primary controller in a Z Wave network Inclusion is the process of bringing new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node Information Frame is a special wireless message issued by a Z_Wave device to announce its capabilities and functions Disposal Guidelines The product does not contain hazardous chemicals Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging
8. artly or completely supported by a specific device 0 0 NEN OO c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 1 Controllers control actuators Actuators report change of status back to controller Sensors report change of status of measured values to controller Sensors directly control actuators Actuators control other actuators Remote controls send signals to static controllers to trigger scenes or other actions Remote controls control other actuators NOOR WD There are two different role a controller can have There is always one single primary controller that is managing the network and including excluding devices The controller may have other functions like control buttons as well All other controllers don t manage the network itself but can control other devices They are called secondary controllers The image also shows that its not possible to operate a sensor just from a remote control Sensors only communicate with static controllers Product description The new Z Wave based Smoke Sensor is an ultra light device that is battery and 12 24 V DC powered for maximum protection from flaming and smoldering fires It has two alarm indicators built in siren and RGB visual indicator The 65 diameter x 28 height mm Smoke Sensor features a built in electronic recording device facilitating an investigation of fire accidents
9. diate cancellation 65535 alarm cancellation inactive Smoke Sensor will keep indicating smoke alarm after the smoke will have disappeared The smoke alarm can be only ceased manually by entering 2nd menu level Default 0 LED indicator and acoustic alarm turned ON OFF at any alarm type Parameter Number 2 Parameter Size 1 activates deactivates the LED indicator and acoustic alarm for any alarm type Doesn t affect the Z Wave alarm Value Description o acoustic and visual alarms inactive acoustic alarm inactive visual alarm active acoustic alarm active visual alarm inactive acoustic and visual alarms active Default c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 9 Type of alarm frame sent to 1 st Association Group devices smoke alarm Parameter Number 5 Parameter Size 1 choose a command class used in 1 st Association Group 0 127 ALARM SENSOR SMOKE command frame 127 255 127 BASIC_SET command frame Default Forced dimming level sent to 1 st association group devices Parameter Number 7 Parameter Size 1 Forced level of dimming opening dimmers roller blinds etc devices at sending turn on open change level commands to 1 st Association Group s devices 1 99 99 means turning on the device with the last remembered status Temperature report interval Parameter Number 10 Parameter Size 2 Time interval
10. int SMOKESNSN FIBARO moke detector Firmware Version 2 1 Quick Start ss This device is a wireless Z Wave sensor To include the device into the network turn the controller into the inclusion mode and then triple click the B button on the casing Further you can use the auto inclusion mode by setting the controller into the inclusion mode and then connect the constant current voltage supply Auto inclusion only works in constant current mode Please refer to the chapters below for detailed information about all aspects of the products usage What is Z Wave This device is equipped with wireless communication complying to the Z Wave standard Z Wave is the international standard for wireless communication in smart homes and buildings It is using the frequency of 868 42 MHz to realize a very stable and secure communication Each message is reconfirmed two way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute an action Controllers are either static mains powered controllers C also referred to as gateways or mobile battery operated remote controls R This results in a number of possible communication patterns within a Z Wave network that are p
11. longs to a network follow the exclusion process before including it in your network Otherwise inclusion of this device will fail If the controller being included was a primary controller it has to be reset first To include the device into the network turn the controller into the inclusion mode and then triple click the B button Further you can use the auto inclusion mode by setting the controller into the inclusion mode and then connect the constant current voltage supply Auto inclusion only works in constant current mode Operating the device SMOKE DETECTION Fibaro Smoke Sensor responds to physical presence of smoke Smoke presence is required for the device to react Fibaro Smoke Sensor performs a self test each 5 seconds and checks for smoke presence Having detected smoke presence the sensor checks 3 more times at 1 second interval whether the smoke is actually present Once the smoke presence is confirmed Fibaro Smoke Sensor triggers an alarm Smoke alarm is signaled by sending an appropriate alarm frame to devices and the Z Wave controller opening NC contact and also by a constant sound signal and LED diode blinking red Once the smoke alarm has ceased the sensor checks 3 times at 1 second interval whether the smoke has actually disappeared before getting back to normal operation i e performing a self test each 5 seconds and checking for smoke presence There are 3 sensitivity levels of the optical smoke detector used in
12. may be performed ONLY in direct range of the main controller 2 If the sensor is to be VDC powered drill holes in sensor s holder Note the sensor may be connected to a wired alarm system controller or fire prevention system 3 Install the sensor s holder in desired location If the sensor is to be VDC powered connect wires observing diagram 3 5 If the sensor is to be connected to an alarm system or fire prevention system connect it observing to diagram 4 gt ALARM SYTEM HUB AUX COM Z1 Z2 ower adapter connection arm system hub connection c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 6 1 On factory default the device does not belong to any Z Wave network The device needs to join an existing wireless network to communicate with the devices of this network This process is called Inclusion Devices can also leave a network This process is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller will be turned into exclusion respective inclusion mode Please refer to your primary controllers manual on how to turn your controller into inclusion or exclusion mode Only if the primary controller is in inclusion or exclusion mode this device can join or leave the network Leaving the network i e being excluded sets the device back to factory default If the device already be
13. ntroller will usually perform all necessary configurations The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device When in battery mode tripple click on the B button to wake up the device It is possible to set the node ID to 255 to send wakeup notifications as broadcast In this mode device takes more time to go to sleep and drains battery faster but can notify all it s direct neighbors about a wakeup Node Information Frame In The Node Information Frame is the business card of a Z Wave device It contains information about the device type and the technical capabilities The inclusion and exclusion of the device is confirmed by sending out a Node Information Frame Beside this it may be needed for certain network operations to send out a Node Information Frame Hitting the B button three times will send out a Node Information Frame Associations a Z Wave devices control other Z Wave devices The relationship between one device controlling another device is called association In order to control a different device the controlling device needs to maintain a list of devices that will receive controlling commands These lists are called association groups and they are always related to certain events e g button pressed sensor triggers In case the event happens all devices stored in the respective association group will receive a common wireless command Association Groups
14. sing visual and acoustic alarms 1 17280 360 means 30min Default 360 temperature measurement compensation for report Parameter Number 88 Parameter Size 1 Consider temperature measurement compensation parameter 73 when sending temperature report o 0 ignore temperature compensation Default 1 include temperature compensation Tamper alarm Parameter Number 89 Parameter Size 1 activates inactivates temper switch alarm c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 12 o 0 tamper alarm inactive 1 tamper alarm active with cancellation option available Default 2 tamper alarm active without cancellation option Command Classes Supported Command Classes Battery version 1 Basic version 1 Wake Up version 1 Association version 2 Version version 2 Multilevel Sensor version 1 Time Parameters version 1 Multi Channel Association version 2 Configuration version 1 Manufacturer Proprietary version 1 Manufacturer Specific version 1 Powerlevel version 1 Firmware Update Meta Data version 1 Alarm Sensor version 1 Technical Data SDK 4 54 02 Device Type Slave with routing capabilities Generic Device Class Alarm Sensor Specific Device Class Routing Alarm Sensor Routing No FLIRS No Firmware Version Explanation of Z Wave specific terms c 2012 Z Wave Europe GmbH
15. your health and well being c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 14
Download Pdf Manuals
Related Search
Related Contents
日本語 - キシダ化学株式会社 4.SEWをSGWに登録しましょう スマートエコワットで省エネ Istruzioni d`uso parte 1 METTLER TOLEDO Comparatori XP Samsung SF-332 用户手册 CAN 14 - Grifo DELL Inspiron 3135 Kwikset 802AVH LIP L03 Instructions / Assembly KSPECTRUM version 1.2.0 User Manual it CALDAIA MURALE A GAS A CONDENSAZIONE en découvrir ou télécharger gratuitement le n°754 (format Copyright © All rights reserved.