Home

- DSOUND

image

Contents

1. Fig 6 Fig 7 a 12V 7 T CAH TO THE ORIGINAL ey Cc 4i2v IGNITION o CONTROLS em KEY SWITCH Y P600 DIODES IGNITION f onmo SUPPLEMENTARY TU KEY SMTCH d RELAY __ Zu DIRECTION 2 INDICATORS HORN F SUPPLEMENTARY aoe RELAY g HORN OL Li 2 ORIGINAL HUN OG SIS CONTROL T d erri n bom FINAL CHECK When installation is complete and the harness connector has been connected to the alam central unit proceed as follows 1 re connect the battery of the machine 2 Turn the machine s ignition key ON and then OFF again 3 50 seconds later the immobiliser will automatically arm the direction indicators flash briefly once the siren beeps once and the LED starts to flash very slowy 4 Disarm the alarm system using the remote control the direction indicators flash once the siren beeps once and the LED switches off 5 Within 50 seconds tum the machine on to check that the connections made are operating correctly 6 Switch the engine off and tum the machine s ignition key OFF Arm the alarm system within 50 seconds the direction indicators flash twice the siren beeps twice and the LED flashes with very brief switches off 7 During the initial 26 seconds immunity period do the following tests which should provide a BEEP if they have a positive result a Turn the machine s key ON b Activate any switch protection opening of the saddle compartment removal of the fi
2. both remote controls twice The siren confirms that the override code has been restored by means of its Beep Beep Boop Boop sequence and the LED then displays the code 11111 All the actions requiring use of the override code can now be completed since it has been confirmed ADDITIONAL REMOTE CONTROLS The alarm system is usually supplied with 2 remote controls called nr 1 and nr 2 It is possible to check how many remote controls are programmed into the alarm system s central unit every time the motorcycle is Switched off i e when the ignition key is turned OFF the LED flashes the same number of times as the number of remote controls To add or remove remote controls from the memory gather all the remote controls together that are to be included in the alarm system s memory new remote controls must be programmed at your dealer s with the code on the red code card that is supplied with the product and proceed as follows 1 disarm the alarm system 2 turn the ignition key ON for 3 times within 5 sec and keep it ON the last time a BEEP sound confirms selection 3 turn the ignition key OFF within 5 sec and insert the override code 4 when the fifth digit is confirmed keep the ignition key ON a series of BEEP BEEP BOOP BOOP sounds confirms the code was correct Di 6 7 8 briefly press the button A of the remote control to be included the LED flashes to confirm reception press the button A of the same remote control again a B
3. EEP sound the LED switching OFF confirms it has been memorised repeat steps 5 and 6 for all the remote controls to be included Any remote controls that are not used e g if lost will be excluded turn the ignition key OFF a series of BEEP BEEP BOOP BOOP sounds confirms the end of the procedure and the LED flashes the same number of times as the number of included remote controls 17 EN V81096B Istr Uso Def Com3 SPECIFICATIONS Power supply Consumption Consumption in Stop mode Operating temperature Sound level of siren 1 m Self supply autonomy Remote controls EN Sensitivity of interna movement sensor Emergency override code to reset immobiliser and alarm functions CAPACTITY OF CONTROLS Starter motor relay Direction indicator relay Horn control TIMING Initial immunity phase Duration of alarm cycle Interval between alarm cycles Passive arming delay Stop mode delay Intermittence of direction indicators ALARM CYCLES Contact alarm inputs Ignition sensing Cable tampering 28 07 2006 29 18 agina 18 12Vcc 10V 15V 1 8 mA O mA 25 C 85 C 114 dB 5 minutes 72 million billion variable codes lithium battery 1 5 per second 10A 5A 5A Negative electronic 300mA 26 seconds 26 seconds 5 seconds 50 seconds 5 days 0 4 sec off 0 4 sec on 10 cycles 10 cycles 9 cycles V81096B Istr Uso Def Com3 28 07 2006 9 29 agina 19 to be cut out and issued to the vehicule own
4. EN DEF COM 3 INSTALLATION MANUAL A PL MotorCycle Alarm MEI INSTALLATION MUN 80 C IMMOBILISER FAIL SAFE SYSTEM Positive Logic the relay switches over when the central unit is disarmed and ignition 15 is present 1 E SUPPLEMENTARY Fig 2 Fig 3 RELAY ey IE 415 d From the magneto Ignition pack prex 5r87 Coil petrol pump i dark blue 1 T 1 RELAY ey H i 3 DEF COM central unit 1 i we NG COIL RELAY DEF COM central unit SWITCH PROTECTION Fig 4 Fig 5 If not used connect the wire to an earth point yellow green PGE SWITCH TO BE INSTALLED INSTALLED CONNECTIONS Fig 1 GENERAL WIRING DIAGRAM C Da Pun v IR P SS is i ANTENNA do not cut and do not tape together with rest of cable harness Positive Negative supply supply 12V LIGHT BLUE Direction LIGHT BLUE indicators Negative BROWN ORANGE Ignition switch command of hom relay positive supply 15 DARK BLUE C YELLOW GREEN Protection against ili removal of earth connection Immobiliser GREY NO connect to earth if not used PURPLE HORN WITH POSITIVE CONTROL SUBKEY HORN WITH NEGATIVE CONTROL SUBKEY
5. ITIAL IMMUNITY PHASE For the first 26 seconds after the alarm system has been armed with the remote control the LED flashes slowly to signal that it is possible to test the protection functions of the system Any alarm triggers do not provoke an alarm but just BEEP sounds by the siren together with the resetting of the initial immunity phase which starts again When this phase is over the LED reverses its flashing sequence short switches on and any alarm triggers will provoke an alarm ACTIVE PHASE This is when the alarm system is armed and after the initial immunity phase is over Any alarm triggers will provoke an alarm cycle that lasts 26 seconds the direction indicators flash the siren when connected emits a distinctive modulated sound the horn will sound intermittently and it will be impossible to start the engine 12 V81096B Istr Uso Def Com3 28 07 2006 9 29 agina 13 PROTECTION BY THE ALARM SYSTEM The alarm central unit protects the motorcycle against being started and an alarm cycle will be triggered every time the ignition key is turned ON an attempt is made to remove or move any part of the motorcycle which is protected by specific switches for example if the seat or the storage compartment is opened the motorcycle is moved the alarm system s supply cables are disconnected or cut or if the motorcycle s battery is disconnected STOP MODE LIMITING CURRENT CONSUMPTION EN The alarm system automaticall
6. code so that it is easier to remember in case of emergency Proceed as follows OVERRIDE WITHIN 10 sEc WITHIN 10 SEC WITHIN 10 sEc WITHIN 10 SEC WITHIN 10 sec EMERGENCY CODE A A FY A See TR KR ATS OFF OFF OFF OFF 2 Beep AJB X1 x3 X1 x2 2 Boop EN 113 E Al SUA B MA SAS NA E Sy SU X1 j Re ON ON ON ON CusrowisiNG OFF Thy l 2 7j 7 OVERRIDE CODE Within 3 sec Keep ON at the third activation confirmation Beep CS X3 NON EMERGENCY CODE NEW OVERRIDE 12113 WITHIN 10 sEc F G H IL WITHIN 10 sec WITHIN 10 stc WITHIN 10 sEc WITHIN 10 stc 2 Beep 2 Boop Y NWY 3 sEC PAUSE QUAN eed 3 SEC PAUSE L Que OFF Lt w o a 9 El 4 D m V81096B Istr Uso Def Com3 28 07 2006 9 29 agina 17 RESTORING THE DEFAULT OVERRIDE CODE Should the driver forget or lose the override code for the product the 11111 default override code can be restored provided he has two remote controls Follow the procedure below to do this Disarm the product using the remote control turn the motorcycle s ignition key to ON and press button A alternately on
7. er m 2 INSTALLATION CERTIFICATE professional installer certify that the installation of the vehicle SYSTEM the undersigned MAKE protection system described below has been carried out by myself in accordance witht to the installation instructions supplied by the manufacturer of the system DESCRIPTION OF THE VEHICLE TYPE SERIAL NUMBER mace MetaSystem REGISTRATION NUMBER DESCRIPTION OF THE VEHICLE PROTECTION SYSTEM TYPE APPROVAL NUMBER Installer s full address and stamp if appropriate at on Signature please specify job position 19
8. immunity phase Reversed flashing 1 BEEP Central unit armed Flashing Alarm cycles Flashing lampeggianti Sounds Disarming without alarms Switches off 1 flash 1 BEEP Disarming when the motorcycle s battery is flat Switches off 4 BEEP Disarming when alarms have been memorised Switches off briefly every 6 sec 1 Beep 1 Boop MEMORISED ALARMS LED sicNALS Internal movement sensor 1 flash Contacts 2 flashes Ignition sensing 3 flashes Tampering with cables or battery 4 flashes If various alarms have been triggered the memory will signal them in a sequence with 3 BUTTON B BUTTON A second pauses and will repeat the sequence every 6 seconds The memory is reset when the motorcycle is started up or when the alarm system is armed with the remote control again The acoustic signal emitted when the alarm is armed and disarmed fails to comply with the national norms in Germany and must therefore be disabled ce 11 EN V81096B Istr Uso Def Com3 28 07 2006 9 29 agina 12 EN PASSIVE ARMING The central unit arms automatically in 50 seconds After the motorcycle s key has been turned OFF or After the remote control has been pressed to disarm the alarm system or After the alarm system has been disarmed using the override code The passive arming is signalled by a short flash of the direction indicators by a BIP from the siren the very slow flashing of the LED only the engine immobiliser is armed It is also possible to select
9. ions to adapt the alarm system to the motorcycle and its driver s needs To set the functions which are described in the table below proceed as follows 1 arm the alarm system with the remote control 2 turn the ignition key ON within 10 seconds the siren will make a BEEP sound to confirm selection 3 press the remote control s button A briefly 4 times the siren will make 4 BOOP sounds to confirm reception of the signal 4 turn the motorcycle s ignition key OFF 5 turn the motorcycle s ignition key ON and then OFF the same number of times as the number of the special function to be set see table Leave the ignition key ON the last time the LED is on 6 briefly press the button A of the remote control once if the settings described in the first column are required see table BEEP column T briefly press the button A of the remote control twice if the settings described in the second column are required see table BOOP column 8 turn the ignition key OFF and briefly press the button of the remote control to exit programming mode otherwise repeat from step 5 to set another function TABLE SPECIAL FUNCTIONS CONFIGURATION factory settings in bold type FUNCTION BEEP BOOP 1 Buzzer when arming and disarming YES NO 2 Direction indicators when arming and disarming YES NO 3 Horn siren alarm output or control of activation Allarm Activation 4 Control of alternate horn or continuous siren Alter
10. nated Continuous 5 Passive arming only of immoboliser or also alarm function Immobiliser Also alarm 6 Passive arming with movement sensor enabled YES NO 7 Alarms of cyclical or single contacts Cyclical Single 8 Enabling of automatic arming YES NO 14 V81096B Istr Uso Def Com3 28 07 2006 9 29 quem 15 OVERRIDE EMERGENCY CODE If a remote control is lost stolen or damaged it is possible to disarm the alarm system with a 5 digit emergency code called the OVERRIDE code The code is found on the label supplied with the remote controls This label must be kept in a safe place and not with the motorcycle The procedure is operational only after the initial immunity phase is over and if the alarm functions are operational alarm cycles will be triggered while the override code is inserted OVERRIDE EMERGENCY CODE Xi Alarm in ON 13212 LE active NW phase after m f AIBICIDIE ON 26 sec 1 3 2 1 2 WirHIN 10 sec WITHIN 10 sec WITHIN 10 sec WITHIN 10 seEc EN OFF Disarm OK WARNING if 3 attempts to insert the wrong code are detected the central unit will be blocked for 30 minutes in order to prevent attempts to search for the code V81096B Istr Uso Def Com3 28 07 2006 9 29 quem 16 CUSTOMISING THE OVERRIDE CODE It is possible to customise the override
11. rewall c Move the machine to activate its tilt protection The timing of the immunity period is reset every time a beep is heard 8 Once the immunity period is over the LED flashes with an reversed sequence long switches off and the alarm system will be triggered for one 26 sec cycle by the activation of any of the protection switches or by tuming the machine s key ON by moving the machineO the siren will produce its distinctive modulated sound the direction indicators flash and the horn if connected will sound intermittently Check the engine immobiliser operates correctly during the alarm cycle 9 When the alarm system is disarmed the LED will remain on and the siren will emit a BOOP sound to signal that it has memorised an alarm trigger refer to the user manual for the code of this signal and for all other features settings of the product V81096B Istr Uso Def Com3 28 07 2006 DEF COM 3 OPERATION MANUAL EN agina 11 MotorCycle Alarm by NIETA SYSTEM wv SIGNALS STATUS OF CENTRAL UNIT LED DIRECTION INDICATORS SIREN Passive arming Slow flashing 1 short flash 1 BEEP Arming by remote control Flashing 2 flashes 2 BEEP Arming without internal lift and tilt sensor On fixed during initial immunity phase flashes 2 1 Beep 2 1 Arming with open contact Flashing 2 flashes 2 Beep 1 Boop Initial immunity phase Reversed flashing Testing during the initial
12. the passive arming of all the alarm system see the paragraph on configuration In this case the signals given are the same as those of arming using the remote control MANUAL ARMING Press the button A of the remote control briefly within 50 seconds of turning the motorcycle s ignition key OFF the direction indicators flash twice and the siren emits 2 BEEP sounds All the central unit s functions have been activated and the LED is flashing ARMING WITHOUT ACTIVATING THE INTERNAL MOVEMENT SENSOR Press the button A of the remote control for approximately 2 seconds and within 50 seconds of turning the motorcycle s ignition key OFF the direction indicators flash 2 1 times and the siren emits 2 1 BEEP sounds All the central unit s functions have been activated except the movement sensor The LED remains on without flashing for the initial immunity phase and then flashes normally DISARMING Press the button A of the remote control briefly the direction indicators flash once the siren emits 1 BEEP sound and the LED switches off if no alarms have been triggered while the alarm system was active If the LED remains on and the siren also emits a BOOP sound this means that the alarm system was triggered To find out how the alarm was triggered consult the MEMORISED ALARMS table If visual and acoustic signals are given during arming or disarming that are different to those described above consult the SIGNALS table to find out what they mean IN
13. y switches off in order to limit the consumption of current in the motorcycle s battery automatically excluding the alarm functions but maintaining the immobilisation of the engine In this condition current consumption is nil STOP MODE is activated 5 days after the system was armed by remote control or automatically passive arming if no alarms were triggered in this time If the motorcycle s battery is almost flat To exit STOP MODE turn the ignition key ON the siren will emit a series of BEEP sounds Press the remote control within 5 seconds of the BEEPS to disarm the alarm system If the remote control is not pressed within 5 seconds an alarm cycle will be triggered EMERGENCY BLINKER The Motorcycle s Blinker can be armed by remote control To arm press button A on the remote control 2 times when the ignition key is in the ON position To disarm press button A on the remote control 1 time when the ignition key is in the ON position NB When the Blinker has been armed by remote control and the ignition key is in the OFF position the alarm can be armed this will automatically neutralise the internal lift and tilt sensor PANIC It is possible to trigger a 10 second alarm cycle by pressing the B button on the remote control This alarm cycle can be interrupted by pressing the same button again 13 V81096B Istr Uso Def Com3 28 07 2006 9 29 agina 14 EN SPECIAL FUNCTIONS CONFIGURATION It is possible to set some alarm funct