1. An ISO 9001 2008 13485 2012 Certified Company Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For EUROVAC ELITE CE Vacuum Gauge Vacuum Control Knob 2195 2 way valve Main Lead er Connector On Off Switch lt gt ABS Enclosure f i a La Bacterial Filter Safety Jar 2 Itr Jar pele with auto motor shut off system gt 2 Ltr PC Jar Jar lt i Back Side Trolley Base Dear Customer Congratulations on your purchase of this versatile and need oriented suction unit It will serve you well for years if properly looked after The medical profession have long felt the need for a lightweight yet powerful easy to move unit on castors with brake mechanism a safe and dependable suction unit EUROVAC ELITE fills this healthcare need to a degree unmatched by any other unit It is designed for use in hospitals operation theaters nursing homes etc Non corrosive and shockproof enclosure is pressure moulded in engineering plastic ABS giving smooth and easy to clean surface ASSEMBLY The pump is housed in the enclosure To fasten it well with the base two black head screws used as holdfast for transportation at the bottom of the unit MUST be removed by rotating anticlockwise with the aid of a simple hand tool Unpack the 5 cartons which contain 1 Trolley base with 5 legs and castors and trolley top 2 Pipe complete 3 1 PC Jar 4 1 PC Jar 5 Main Top uni
2. are on one side of the two pump housings and the red ones on the other sides e Please run the unit and see its satisfactory functioning before the back plate is screwed up Unlike the rotary design NO LUBRICATION IS REQUIRED IN THIS PUMP The unit has not to be tampered with by any mechanic other than our factory engineer or the person authorized S3 Foot Switch Filter CD f Patient 1 Vacuum Cc ap N Electronic Safety Sensor lt j Jar PC CARD 220V AC Outlet Outlet MOTORIZED PUMP www anandind com Page 4 www suction india com Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For EVROVAC ELITE TROUBLE SHOOTING Possible source of trouble Check Action to be taken Power Supply Voltage power socket Main Mainswith ss Set at Setat ONN Mate slip eae cord e a type plug connections damaged cord Check if the safety jar is activated Open the safety jar clean amp dry the jar and replace the cap for re use a The blood has entered the pump The remedy is given above under pump cleaning Not Run Ta 09 O O O O Leak within the pump or in the external Isolate the source of trouble by carrying out suction circuit the checks outlined External cause Push in connector O rings Lid gasket Condition Blockage or kink in tubing within the Isolate source of trouble as follows Inadequate Suction Performance pump or in the externa
3. concerned satisfy the requirements laid down by IEC e The appliance is used in full accordance with the instruction manual which is solely a guide and no substitute for professional training The safe and effective use of this product largely depends on the skill of the operator We are not liable for any damages due to mishandling or improper and unauthorised use e The company reserve the right to change technical specifications designations and catalogue numbers without prior notice Note Ensure that your electrical wirings are well earthed with 1 line and 1 neutral phase and your voltage is between 220V 240V 50 Hz Ensure that the suction unit should not be lifted above human body level Dispose of used product packaging in safe manner so as not to harm stray cattle children and environment WARRANTY CARD Model No ____ LULL Le LLL LLL LL SN eee eee Date of Purchase Dealer Name ual ANAND MEDICAIDS PRIVATE LIMITED Regd Office 33 16 Punjabi Bagh Extn New Delhi 110026 India Tel 91 11 25225225 25229206 42464264 Fax 91 11 25225062 E mail sales anandind com Works 1460 M I E Bahadurgarh Haryana 124507 India EC REP KALEIDOS SH VIA PONTIOA 4 2012 MILANO ITALY www anandind com Page 6 www suction india com
4. d com Page 2 www suction india com Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For EUROVAC ELITE GUIDELINES FOR USE Negative Pressure After each use lids overflow cut off valve suction cannulae catheters etc should be cleaned thoroughly When sterilization is necessary after infective fluid has been sucked the jars the lids cut off valve and metal cannulae can be sterilized by autoclaving and the tubing by sterilizing solution Jars Tubings The material of the jars polycarbonate PC is superior to glass It is less fragile when subjected to impact and less sensitive to temperature shock PC is resistant upto 120 C provided it is not subjected to any physical loading As the flow rate is high 3 4th filling of the jar is recommended The lid has a built in antifrothing device The jars are easier to clean if a little water or disinfectant is put into them prior to suction operation The safety jar must however remain dry Tubing after repeated use can be brittle and must be changed 2 Ltr PC Jar Cleaning and Disinfecting After each use jars lids overflow cut off valve catheters etc should be cleaned thoroughly When cleaning is necessary after infective fluid has been evacuated the jars lids cut off valve and tubing can be sterilized by autoclaving upto 120 C for 20 minutes Alkaline cleaning agents and disinfectants based on phenyel may not be used Adherence to hospital directives on
5. hygiene is of prime importance The instructions provided by the suppliers of cleaning agents as well as by the manufacturers of sterilization and or disinfection units must also be followed where application temperature process duration and airing etc are concerned Bacterial Filter www anandind com Page 3 www suction india com Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For EVROVAC ELITE PUMP The unit is fitted with a dual head pump based on the diaphragm system The finest diaphragms suck and throw air through the two specially designed Fly umbrella valves The life of these three rubber parts is 400 to 800 working hours subject to the proper following of the instruction a To reach the pump open the back plate of the unit with the aid of an allen key provided The pumps are marked INLET vacuum with green stickers and OUTLET Exhaust with red stickers The plates of the pumps are l marked 4 3 2 and 1 Disconnect the tube from the combined inlet on the Motorized Pump pump housings b Unscrew the two hexa bolts from the bottom of the unit and take out the motorized pump fitted on and together with the platform c The fly valves are placed between plates 4 and 3 tucked on the center pins on plate 3 The plate No 2 holds the top of the diaphragm fitted on the crank shaft with bearing moving on the motor shaft d All the plates are to be assembled in such a way that the green stickers
6. ion Power 220 V 50 60 Hz 125 watts 110 V on request Dimension amp Weight 46 x 42 x 111 cms 15 6 kg Controls on working height with extra pedal operatable switch Trolley with non marking castors having brake facility VACUUM AT ALTITUDES The specified maximum vacuum refers to sea level According to local conditions and barometric pressure slight deviations in vacuum reading may be noted As a reference the table below shows several factors by which the indicated maximum vacuum value must be multiplied according to the altitude of location where the measurement is carried out Location Maximum Vacuum Location Sea level 1000m 2000m 4000m Factor 1 00 0 88 0 78 0 60 Before the unit is put on please see that 1 0 rings on push in connectors and safety jar arm are not worn out 2 Jars are checked for possible crack or flawed spots Any defect can result in implosion under vacuum 3 Check the bacterial filter and change the filter element if necessary The housing must be flip tightened The safety jar with two O rings must be well inserted in the holder 4 The lids and tube are tightly placed on the jars To avoid leakage the push in and angular connectors must be inserted as far as the stop While unplugging twist and pull 5 The main power supply is well earthed In case of fluctuation use voltage stabilizer corrector 6 The vacuum control knob is not loose It must be fully tightened clockwise www anandin
7. l suction circuit Remove the safety jar leave the suction connection open If the vacuum gauge now indicates zero vacuum the cause is external External cause Bacteria filter safety jar overflow valve in the Investigate the whole external suction circuit lid float valve push in connectors tubing etc for blockage s float valve sticking kinked tubing and rectify If the vacuum gauge still indicates a vacuum Pump does not suck however the cause is internal Vacuum gauge indicates a vacuum www anandind com Page 5 www suction india com Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For EVROVAC ELITE TERMS OF WARRANTY Anand Medicaids Private Limited warranty the high quality and workmanship of each Anand s HI VAC for a period of one year subsequent to the date of delivery by the company During this period faulty material will be replaced free of charge This warranty does not extend to components that are subject to wear and tear in the course of normal operation or due to improper treatment maintenance as per instructions Further conditions in accordance with international standard IEC 601 1 item 6 8 2b The manufacturer is only responsible for effects on the safety the reliability and the performance of the appliance if e Installation additions adjustments modifications or repairs are carried out by personnel authorized by the manufacturer e The electrical installations within the room
8. t EUROVAC Install the pipe complete portion marked bottom onto the trolley base with the help of 2 alllen bolts fitted in the pipe bottom portion Tighten it from below the base Remove the two hexa bolt fasteners and four nuts from below the top unit Eurovac Fix the top plate on pipe and place the unit on the trolley top Tighten the top unit on trolley top with these four hexa nuts from below the trolley top www anandind com Page 1 www suction india com Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For EVROVAC ELITE Two way valve is slipped into the side anchor On the back of the top unit is fitted the safety jar and into it the bacterial filter which is connected to the middle slot of the two way valve The side slots are connected to the middle slot of the two way valve The side slots are connected to the two nozzles on the jar lids The other nozzles in rotation are for Patient connector on the two jar lids Plug the cord into the main unit socket on side and the unit is ready for use TECHNICAL Housing Engineering moulded ABS plastic box Capacity 700 mm Hg 10 Vacuum 35 Ltrs min Pump Type Double diaphragm pump Jar Wide mouthed 2 x 2 5 Ltrs Polycarbonate with two way changeover lever and safety jar with mechanical electronic overflow motor shut off system and autoclavable bacterial filter Tubing 8 mm ID x 2 mtr Silicon Vacuum Gauge 6 25 cms 2 5 inch 0 760 mm Hg calibrat