Home
Manual (english)
Contents
1. In this case there is no malfunction of the device Do not turn the device on and off within short periods of time e g matter of seconds N Health risk Avoid looking directly into the source of light lt may cause epileptic seizures This applies in particular for people where epileptic seizure has been diagnosed by a doctor Keep children and amateurs away from the device 2 2 Operation of the device in accordance with its intended purpose The AIR BASE 850 MK2 is a lamp housing which was developed for professional use on stage in discotheques theatres etc The device is only approved for a voltage with a maximum of 230 V 50 60 Hz AC and suitable for indoor use only Regular stoppages increase the life of your device Avoid shocks or any kind of violence during the installation or starting up of the device 5 15 ignition AIR BASE 850 MK2 Make sure that the device is not exposed to extreme heat humidity or dust at the installation spot Make sure that cables do not lie around This would decrease your own safety and the safety of third parties The device may not be operated or kept in an environment where splashing water rain humidity or fog is expected Moisture or very high humidity can reduce the Isolation of the device and result in lethal electric shocks When using fog machines never expose the device directly to the fog stream Keep a safety distance of at least 0 5 m between the device and the fog mac
2. the inserted device 9 SCHUKO socket max 10 A 3 3 How to use the Power Switch The power switch has 3 Steps Here follows the explanation for it Step 1 Normal working conditions That means the air pressure sensor is switched on and the power plug inside is switched on according to the pressure That s in this state to prevent the running moving head from twisting the rain cab if the air pressure is not strong enough Then the air pressure sensor shuts down the power plug inside Step 2 Installation Mode In this Mode the Air pressure sensor is switched off and the Power plug is switched On That s in this state that you can adjust the settings and addressing of the fixture without the rain cab Step 3 Hard Reset OFF This mode shuts down the internal Power Plug that you can do a hard reset for the moving light without removing the cab NOTE The AIR BASE 850 MK2 contains an air pressure sensor Only if the total air pressure is built up in the air cone the power plug will give power to the items inside Do not be surprised if only then there s electricity from the socket outlet That s for safety reasons so a moving head will not rotate uncontrolled and entangles itself in the foil 13 15 ignition AIR BASE 850 MK2 4 Technical data Input Voltage AC 100 240V 50 60Hz Features Air pressure sensor 4 step fan 3 way switch NEUTRIK XLR 3 PIN Can be hanged Included accessories 1 5m HO5VV 3G 1 5m
3. 10 15 ignition AIR BASE 850 MK2 2 4 Additional warnings fe SM a Make sure the AIR BASE 850 MK2 is properly earthed If the fuse is destroyed replace it with one of the same type The operating temperature may not exceed or fall below 5 C 45 C The device is not easy to move in operation state Avoid accidents Please don t open any parts of the AIR BASE 850 MK2 except those which are meant to Inside are high voltage cables Please contact appropriate qualified personnel or your local dealer if there are any questions 11 15 ignition AIR BASE 850 MK2 3 Product description 1 This product provides suitable holding fixtures for e g LED Par 151 LED Base 4 or Studio Pars etc 2 There are two carrying handles for transporting and carrying the Airbase comfortably and easily 3 On the bottom are rubber bumpers So the Airbase is shock resistant quiet and slip resistant 4 The Power Case is easy to install and removable from the housing if needed A AIRBASE 850M9 1 AIR PRESSURE SWITCH ON 2 AIR PRESSURE SWITCHOFF POWER ON 3 POWER OFF Neutrik 3pole and 5pole XLR DMX Output Neutrik 3pole and 5pole XLR DMX Input Switch for Power Modes 3 Steps Powercon In for Mains Fan Switch in 4 Steps Se u E Zen 12 15 ignition AIR BASE 850 MK2 3 2 Power Case upside 6 10A fuse and fuse holder with VDE certificate AC 100 240V 7 DMX output for connecting the inserted device 8 DMX input for connecting
4. NIGION USER MANUAL e Airbase 850 MK2 ignition AIR BASE 850 MK2 Table of contents A A A 3 1 1 POR SAFE AND EFFICIENT OPERATION een ee 3 2 Co Sa 4 241 Secuela lcd sra 4 2 2 Operation of the device in accordance with its intended purpose occcccccconcccncccnnncconcnonnnnconnnos 5 200 Cleaning ANG maintenant rmac AAN A NN 10 2A PRCT WINS cusco 11 3 ZRLOQUEBASSEHIDTION Sees A 12 3 1 Power Case bottom side ooccccccccccccccnncccnnncconnnoonncnnnnnnonnnnnnnnnnnnnonononnnnnnnnnononnnnnnnnnnnnnnnnnnnenoss 12 3 2 Power Case Upside viii iia 13 3 3 How to use the Power SWItCh ooccccccconnccnncccconconnconnoncnnnnononncononononncnnnnonannrnnnnnnnnrnnnonnnanennnoss 13 4 Teehniealdala ze eier elek enter ereeeeheee 14 2 15 ignition AIR BASE 850 MK2 1 Safety instructions e This device is suitable for indoor use only e All modifications to the device will void the warranty e Repairs are to carry out by skilled personnel only e Use only fuses of the same type and original parts as spare parts e Protect the unit from rain and humidity to avoid fire and electric shocks e Make sure to unplug the power supply before opening the housing 1 1 FOR SAFE AND EFFICIENT OPERATION Be careful with heat and extreme temperature Avoid exposing it to direct rays of the sun or near a heating appliance Not put it in a temperature bellow 23 F 5 C or exceeding 113 F 45 C Keep away from h
5. SCHUKO NEUTRIK POWERCON Power Input 55W max Material Aluminium Colour Polished Protection class IP 20 Product Size L850 x W850 x H285mm Net Weight 21KG 14 15 ignition AIR BASE 850 MK2 Importeur B amp K Braun GmbH Industriestra e 1 D 76307 Karlsbad Ittersbach www bkbraun com info bkbraun com X RoHs a BER 15 15
6. allation before initial start up 9 15 ignition AIR BASE 850 MK2 2 3 Cleaning and maintenance The entrepreneur is obliged to get an expert to check safety related and mechanical facilities within the limits of an acceptance inspection at least every four years The entrepreneur is obliged to get an expert to check safety related and mechanical facilities at least once a year Thereby particular attention must be paid to the following items 1 Ensure all screws attached to the device or parts of the device are very tight and not corroded 2 Ensure there are no deformations of the housing attachment and installation space This also includes the ceiling the suspension and the truss 3 Electrical connection cables may not have any damages depositions or signs of material aging e g porous connections A Danger Disconnect the device completely from the electricity grid during maintenance work Contaminations like dust should be removed regularly from the device Use a lint free damp cloth Do not use alcohol or solvents under any circumstances Use a vacuum or an airbrush for cleaning the device s interior Carry out an appropriate cleaning once a year Service and maintenance must be exclusively transferred to authorized specialized trade If you require spare parts for the device please use only original spare parts If the mains cable is damaged it must be replaced by authorized specialized trade to avoid hazards
7. e the original packing for transporting the device to avoid transport damages Make sure the device is packed like it was shipped straight from the factory Unauthorized manipulations of the device are forbidden for safety reasons A usage of the AIR BASE 850 MK2 which differs from the described one in this manual can result in damages of the device In this case the warranty is no longer valid In addition it is to be considered that every differing usage is dangerous and can result in e g short circuit fire electric shock crashs Overhead installation N Danger During installation please follow the regulations of the BGV C1 former VBG 70 and EN 60598 2 17 Installation may only be carried out by authorized specialized trade AIR BASE 850 MK2 s suspension devices have to be build and measured so they can withstand for an hour the tenfold of the payload without suffering a permanent detrimental deformation Basically the installation has to be made by using a second separate suspension This can be e g a suitable net The second suspension must be designed and attached so no part of the installation can fall down in case of failure of the main suspension During construction reconstruction and deconstruction unnecessary stay in the range of moving areas on lightning bridges under elevated work stations or any other danger zones is forbidden The entrepreneur is responsible for getting experts to review safety related and mec
8. efully before the initial start up of the device All persons responsible for installation starting up operation maintenance and repair must Have an equivalent qualification Follow exactly the instructions of this manual Consider this manual as a part of the product Keep the manual safe over the entire lifetime of the device Pass the manual to future owners or users of the device Download the latest version of the manual from the internet 2 1 Security related warnings A Attention Be very careful when dealing with dangerous mains voltages There is the risk that you can suffer a very serious electric shock 4 15 ignition AIR BASE 850 MK2 After taking the device from a warm to a cold room it may not be put into operation The resulting condensation can possibly destroy the device Do not turn on the device until it has reached ambient temperature Avoid contact of the mains cable with other cables Be very careful when dealing with mains cables and mains connections Never touch those with wet hands Make sure that the voltage to be connected does not exceed the specified values Make sure there is no stress or damage of the mains cable due to sharp edges Make sure that the device and the mains cable do not show any signs of damage by running regular inspections Disconnect the device from the grid when not using it and before cleaning During the initial start up of the device smoke or smells may occur
9. hanical facilities before initial start up or after crucial changes before restarting 7 15 ignition AIR BASE 850 MK2 The entrepreneur is obliged to get an expert to check safety related and mechanical facilities within the limits of an acceptance inspection at least every four years The entrepreneur is obliged to get an expert to check safety related and mechanical facilities at least once a year How to precede the overhead installation The device is ideally installed beyond public areas IMPORTANT Overhead installation requires a high level of experience This includes Knowledge of calculating the payload used installation material and safety inspections of the used installation material and the projector whereas the required experience is not limited to this Do not try to carry out installation yourself under any circumstances if you are not qualified Contact a professional installer An inappropriate installation can lead to injuries and or damaged properties The device may not be installed within the reach of persons If the device is supposed to hang from a ceiling or from high beams the use of truss systems is mandatory The device must be installed that it s not possible it can swing in the room Attention Crashing down devices can cause serious injuries DON T install the projector if you doubt the safety of a possible installation form Before installing the device ensure that the installation space suppo
10. hine Take care that the fog saturation enables a good visibility of at least 10 m The ambient temperature must be between 5 C and 45 C Avoid exposing the device to direct rays of the sun or next to a heating appliance This also applies for transportation in closed vehicles A relative humidity of 50 at an ambient temperature of 45 C may never be exceeded The device may only be operated at a level between 20 and 2000 meters above sea level Do not operate the device during thunderstorms Overvoltage could destroy the device Disconnect the device during thunderstorms completely from the grid by pulling the mains plug During installation the use of a mounting bracket is required To ensure good air circulation keep a free space of at least 50 cm around the device Surrounding objects or surfaces may not be touched by the housing Make sure that during installing and uninstalling of the device the area below the installation spot is blocked in principle This also applies for performing service and maintenance The device must always be secured by an appropriate safety rope Familiarize yourself with the functions of the device before operating it Do not let inexperienced persons operate the device Major cause for malfunctions is an incorrect usage of the device 6 15 ignition AIR BASE 850 MK2 Never use solvents or aggressive cleaning agents for cleaning the device Use a soft and damp cloth instead Please us
11. rts at least the tenfold point loading of the device s deadweight Mount the projector with the mounting bracket on an appropriate hook of a truss system 8 15 ignition AIR BASE 850 MK2 During overhead installation the projector must be always secured by a safety rope which is designed to hold the twelvefold weight of the device Only safety ropes with quick release safety fastener elements may be used Hang up the safety rope in the hole of the mounting bracket Direct the rope over the truss or an appropriate fastening point Hang up the end in the fastening element and tighten the locking nut The maximum falling distance may not exceed 20 cm A safety rope once exposed to falling load or damaged may not be used furthermore Adjust the inclination with the mounting bracket and tighten the locking screws firmly Connection to the grid A Danger Contact the authorized specialized trade for connection to the electric supply Do not carry it out yourself Connect the device via mains plug to the grid If the device is directly connected to the local electricity grid the installation of a separator with at least a 3 mm contact hole for each pole is necessary The connection is exclusively permitted for electrical installation which complies with the VDE regulations DIN VDE 0100 Indoor installation must be equipped with an earth leakage circuit breaker RCD with 30 mA rated current A Danger An expert must check the inst
12. umidity water and dust Do not place the set in a location with high humidity or lots of dust Containers with water should not be placed on the set Keep away from sources of hum and noise Such as transformer motor tuner TV set and amplifier To avoid placing on un stable location Select a level and stable location to avoid vibration Do not use chemicals or volatile liquids for cleaning Use a clean dry cloth to wipe off the dust or a wet soft cloth for stubborn dirt If out of work contact sales agency immediately Any troubles arose remove the power plug soon and contact with an engineer for repairing do not open the cabinet by yourself it might result a danger of electric shock Take care with the power cable Never pull the power cable to remove the plug from the receptacle be sure to hold the plug When not using the device for an extended period of time be sure to disconnect the plug from the receptacle 3 15 ignition AIR BASE 850 MK2 Important Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems Make sure the electrical connection is carried out by qualified personnel All electrical and mechanical connections have to be carried out according to the European safety standards 2 General warnings A Attention Disconnect the device completely from the grid before opening it Please read this manual car