Home
Cerber C62 - ElektroMech
Contents
1. OFF ON while the master user is being within menu of program modify the user codes follow me phone numbers or system time and date ON while the installer is being within programming menu of the system parameters ARMED B LED a While the partition B is armed ON if the partition B is totally armed Fast Blinking if the partition B is armed in instant stay mode Fast Blinking during any arming period after any delayed zone which belongs to the partition B triggered the alarm Slow Blinking if the partition B is armed in stay mode b While the partition B is disarmed OFF Zone LEDs a While the system is completely armed e ON the corresponding zone triggered the alarm at least once during arming e Blinking if zone tamper condition occurred e f the corresponding zone triggered the alarm at least once and tamper condition had occurred on the same zone during armed state of the system zone LEDs are ON for 2 seconds and blinking for the next 2 seconds and so on b While the system is completely disarmed or partial armed e OFF the loop of corresponding zone is closed e ON the loop of corresponding zone is faulted e While the system finds itself within one of the programming displaying menus o ON the user is being within one the zone bypassing menu and the respective zone is bypassed o ON OFF they are displaying certain parameters status activate deactivate while the installer is bein
2. All users have ambush capability by pressing the key which corresponds to the ambush digit before the 4 or 6 digits of any user code then the control panel will transmit a special code to the central station INSTALLER CODES e 2 programmable installer s codes installers programming code and installer s maintenance code the first installer s code is only for system parameter programming and the second one with same 11 programmable rights and ambush capability as the 45 user codes except the Disarming right which is allowed only if the system partition was previously armed by the same code DiGI TAL COMMUNI CATOR Phone line tone detection upon the automatic initiating the reporting to the central station 2 separate accounts and individual communicator formats to identify each partition upon transmission to central station 2 individual programmable phone numbers for transmission to CS1 and to CS2 Alternate or Split double reporting to CS1 and to CS2 1 FIFO buffer which storages up to 80 events for transmission to CS without erasing the old events in case of CS1 and CS2 communication failed event if alternate reporting is selected 2 FIFO buffers which storage up to 80 events each for transmission to CS1 and to CS2 without erasing the old events in case of CS1 communication failed event and or CS2 communication failed event if split or double reporting is selected Adaptive algorit
3. 1 Selective Programming Erasure of 01 to 45 user codes master user s submenus from 01 to 45 21 2 Simultaneous Erasure of all user codes except the master code master user s submenu 49 3 Selective Programming Erasure of the follow me phone numbers master user s submenus from 51 to 54 4 Simultaneous Erasure of all follow me phone numbers master user s submenu 50 Programming session of the system time and date master user s submenu 60 6 Ambush Digit Programming master user s submenu 61 While the system is being within master user s programming menu in order to program the 01 to 45 user codes the follow me phone numbers the system time and date or the ambush digit select one of the 01 to 45 49 50 51 to 54 60 or 61 master user s submenus To enter each master user s submenu the master user should enter 2 digits which are corresponding to the order number of each submenu i e for submenu no 9 press 0 and 9 keys After entering the 2 digits corresponding to the order number of one submenu the keypad buzzer will beep for 3 times confirming the system is being within respective submenu Once the system was entering one of the master user s submenus the keypad LEDs status will be as follows Remarks ARMED A LED ON SYSTEM LED Blinking READY LED ON zone 1 2 and 3 LEDs Blinking That means the selected user code the follow me phone
4. Any alarm latch Pulsing siren Steady siren silent alarm latch Follow system status ON while system is armed OFF while system is disarmed Entry delay Exit delay System troubles Clock timer Warning confirmation n u n u n u pulses Buzzer warnings during the warning round time Pulse after exit delay Pulse on arming n u Pulse on Disarming Courtesy light Pulse on round OK Pulse on round failed Pulse on siren troubles Retriggerable mono stable Resetable mono stable Bi stable and Pulse on alarm triggered by each 1 to 6 zones MONI TORI NG OF SYSTEM TROUBLES Battery Voltage and AC power monitoring Siren monitoring upon disconnection or overload AUX overload monitoring Option of telephone line monitoring TLM Status of zone tampers if enabled zone tamper recognition VOI CE MESSAGES SYNTHESIS SOUNDS COMMUNICATOR Capability of response to the remote calls for system status interrogation the system status armed disarmed alarm AC power loss will be reported by specific voice messages or by specific synthesis sounds Programmable options of responses to the remote calls for system status interrogation either after double call or after programmable number of rings Programmable option of automatic initiating the reporting the specific voice messages or the specific synthesis sounds to the follow me phone numbers when several alarm and A
5. in order to visualize zones that went into alarm or special alarms triggered from keypad Soon after entering lt and gt keys SYSTEM LED will fast blink indicating the system is being within global visualization menu for alarms triggered by zones LEDs of zones that triggered the alarm will also fast blink Press key to view the special alarms triggered from the keypad READY and SYSTEM LEDs will fast blink indicating the system be in the global visualization menu for the special alarms Within visualization menu of special alarms LED 1 indicates an alarm triggered from keypad panic fire medical emergency and LED 2 indicates a keypad lockout alarm after too many wrong codes Exit the visualization of special alarms by pressing key again Since the system was in the menu of alarm memory display press lt or gt key to visualize the order of the first 9 alarms triggered in the system Upon pressing gt key the system will display the next alarm Upon the 1 press the system will display the 1 alarm the 9 alarm being displayed upon the 9 press If gt key is pressed more than 9 times the system keeps displaying the 9 alarm You can press a key from 1 to 9 any time for the system to display the alarm corresponding to the key pressed Next if 2 key is pressed the system will display the next alarm until the 9 one Upon pressing key the system displays the previous alarm If the system is displa
6. is dedicated to the installer and system parameter programming from PC software is still required 3 Within panel programming by PC Upload Download denomination there are several operations which any user or the installer can perform them while a connection between the modem of PC and control panel is established The following operations can be performed Uploading the system parameters into EZcom C62 Software 29 Downloading the system parameters from EZcom C62 Software into the control panel Uploading the event LOG from the control panel into the EZcom C62 Software in a file System time and date setting by PC System or partitions arming Disarming from PC Zone bypassing by PC PGM activation deactivation by PC only for PGM outputs defined as mono stable bi stable or clock timer types Online visualization of the system partitions status and troubles onto EZcom C62 Software Online visualization of the bypassed alarmed or open zones onto EZcom C62 Software Remark CERBER C62 provides 2 methods of triggering the communication with PC 1 The control panel answers automatically to the PC calls either after double call or after the ring number which was set in section 43 2 By means of the manually triggering command accessible to the master user the control will answer to the PC calls Once 8 Master Code 98 command is entered the control panel will try to establish the commu
7. or 2 LEDs are flashing allowing the user to choose the disarmed partitions to be armed without codes to arm the partition A the user must pres 1 key and to arm the partition B the user must pres 2 key please note that if the user is pressing the key which corresponds to an armed partition the keypad buzzer will sound a long beep Note Quick arming features are allowed only if the appropriate options are enabled by programming see the options displayable on zone 1 2 and 3 LEDs within programming section 23 AWAY QUICK ARMING 0 O or INST CODE where INST and CODE are the keys labeled INST and CODE Away quick arming away arming without code is performed by entering one of the sequences 1 0 0 or INST CODE After that the user must leave the objective before the exit delay elapsed After the exit delay elapsed the system is entirely armed and the ARMED A LED will remain ON This arming type is similar to away arming by user code Note Away quick arming is allowed only if the appropriate option is enabled by programming see the option displayable on zone 1 LED within programming section 23 QUICK INSTANT STAY ARMING 0 1 This arming type is similar to instant stay arming by user code 15 Note Quick instant stay arming is allowed only if the appropriate option is enabled by programming see the option displayable on zone 2 LED within programming s
8. or by keyswitch if the user doesn t leave the protected area through any entry exit point during the exit delay Option no beeps dings during the exit delay of stay arming modes Option Autoarming programmable in regular or home mode Option dings audible sounds on the siren on keyswitch arming Disarming arming Disarming unless keyswitch arming Disarming and during exit delay or for 3 minutes before timed autoarming Option programmable period and pause for ding sounds Audible warnings for 3 minutes before timed autoarming 3 minutes before timed autoarming on the keypad buzzer and ding sounds optionally Keyswitch arming Disarming or stay arming Disarming as an option Programmable protection against undesired resets to default values Chime feature activated deactivated by the users Fuseless design system designed with electronic fuse control to function without fusible resistors Current limitation for backup battery charging 200mA TECHNICAL SPECIFI CATI ONS POWER e 12V AAh battery 16Vac 20VA transformer Current consumption in stand by 50mA control panel 12mA keypad MPV 10mA Current capability on AUX typically 1A 2A maximum fuse less electronic shutdown at 2 2A automatic restore I NPUTS 6fully programmable EOL zones MAIN BOARD OUTPUTS 2 open collector outputs with negative trigger NPN max 50mA open collector supervise
9. previously and if the master user wants to change his rights he must call his installer 2 The master code erasing isn t allowed If by mistake master user is trying to erase the master code by selecting the order number of the master code 01 and then entering key the keypad buzzer will sound a long rejection beep and the panel will go back within master user s programming menu The control panel will keep the old value for the master code 3 02 to 45 user codes have only second right enabled by default and master user can change them while he is being within corresponding session of the selected user code programming erasing Any user code from 01 to 45 can be selected in order to get a new value or press key to exit the master user s programming menu SIMULTANEOUS ERASURE OF ALL USERS CODES EXCEPT THE MASTER CODE 7 Master Code 49 or CODE Master Code 49 where CODE is the key labeled CODE While the system is being within master user s programming menu to simultaneous erase all user codes except the master code select the corresponding submenu 49 by entering the 2 keys 4 and 9 The keypad buzzer will sound 6 confirmation beeps and the control panel will go back into master user s programming menu Any user code from 01 to 45 can be selected in order to get a new value or press key to exit the master user s programming menu PROGRAMMING SELECTIVE ERASURE OF THE 1
10. status will be as follows Remarks ARMED A LED ON SYSTEM LED Blinking READY LED ON 25 While the system is being within programming session of the selected phone number the keypad LEDs status will be as follows Remarks That means the selected phone number was programmed during a previous programming Zone 1 2 and 3 LEDs Blinking session That means the selected phone number isn t programmed and the control panel is only zone L LED Blinking waiting for the first digit for the new value of the selected phone number 1 and 2 zone LEDs Blinking That means the selected phone number is being programming 1 Programming Erasing of the selected phone number can be canceled by key pressing After 4 key pressing the keypad buzzer will sound 6 confirmation beeps and the control panel will go back within master user s programming menu 2 In order to program the selected phone number you should enter maximum 15 digits as you would on a key phone 2 1 After entering the first digit of a new sequence for selected phone number the 1 and 2 zone LEDs will be blinking That means the control panel is waiting for the other digits for the new value of the selected phone number 2 2 A 2 second pause can be added by entering HEX digit D between the digits of the phone number enter HEX digit D by pressing and 3 keys 3 after the last digit of the just programmed phone number was enter press key to confirm the new valu
11. stopped The PGM1 or PGM2 output will change again its status when the system clock is identical with the time established in 81 or 82 section for PGM1 and in 83 or 84 section for PGM2 After entering the last digit of a valid user code within this sequence 9 User Code the keypad buzzer will sound 3 confirmation beeps passing to display on zone 1 2 and 6 LEDs the status of PGM1 PGM2 and rounds respectively as follows While the system is being within displaying of the status of PGM1 PGM2 and rounds the keypad LEDs status will be as follows ARMEDALED ON SYSTEM LED Blinking READY LED ON zone 1 LED ON OFF according to the PGM1 status zone 2 LED ON OFF according to the PGM2 status zone 6 LED ON OFF according to the status of rounds 20 1 Status of PGM1 PGM2 and rounds can be maintained as it was previously established by key pressing 2 In order to turn activate deactivate PGMI only if it is set as retriggerable or resetable mono stable as bi stable or as clock timer the user should press 1 key and the zone 1 LED will turn ON OFF If the zone 1 LED is ON means PGMI is activated and if the zone LED is OFF means PGM1 is deactivated Any successful command of PGMI activation deactivation is followed by an automatic exit from menu after about 1 second like after key pressing after 1 sec 3 In order to turn activate deactivate PGM2 only if it is set as retriggerable or resetabl
12. system partitions status and LOG buffer to be retained even after a total power loss User friendly programming of the system parameters from keypad or by PC using EZcom C62 Software Up to 400 events with time and date stamp can be stored in a FI FO LOG buffer False alarm prevention features intellizones automatic zone shutdown beeps on entry and exit delays Features of sensor under test for easy detection of the sensors which produce false alarm High speed pre programmed or programmable Communication Formats e 45 user codes 1 being master code and 2 installer s codes programming and maintenance codes Keypad displayed alarm memory for the first 9 alarms occurred in the system since last arming Up to 4 keypads which can be simultaneously 4 wire coupled to one central unit Keypad protection using micro switch tamper Individual zone LEDs from 1 to 6 indicating the alarm and faulted status Each zone accepts tamper recognition by zone attribute programming and 2EOL wiring System status LEDs READY SYSTEM ARMED A and ARMED B UsER CODES 45 programmable user codes 1 being master code with 11 programmable rights Zone bypassing Regularly arming Stay arming Force arming Disarming siren stopping PGMI activating deactivating PGM2 activating deactivating Access to partition A Access to partition B Starting the rounds Finishing the rounds
13. the system partition will be armed o System troubles by means of 4 command if there are troubles regarding AC power loss low voltage on battery fail to communicate event BELL trouble AUX overload phone line trouble or system time and date loss fix all these troubles before arming Notes 1 Ina partitioned system in order to arm a partition by users assigned to only one partition simply key in a valid user code the corresponding partition will arm after exit time 2 n a partitioned system in order to arm the partitions by users assigned to both partitions key in a valid user code the zone 1 and 2 LEDs will flash for 5 second allowing the user to choose the partition partitions to be armed by pressing 1 and or 2 keys The selected partition partitions will arm after exit time OTHER ARMI NG MODES TIMED AUTOARMI NG If timed autoarming option is enabled within 26 and or 27 sections the system partitions will automatically arm itself at a specified time everyday Please note as with regular arming the system partitions will not auto arm if a zone is violated and force autoarming is not enabled or if the zone doesn t allow forced arming If this occurs the control panel will report fail to auto arm code and the system partition will not arm until the next day The type of autoarming is regular or stay and is dependent on the appropriate options within 26 and
14. then the starting finishing the rounds and PGM activation deactivation by users will be transmitted to CS 5 If no successful command was performed finally the user should press key to exit from the visualization of the status of PGM1 PGM2 and rounds The keypad buzzer will sound 6 confirmation beeps and the system will go back within armed disarmed status the keypad LEDs being displaying the system and zone status 4 Master User s Programming Menus While the system is partially armed in order to enter the main programming menu allowed only to the master user enter one of the 7 Master Code or CODE Master Code commands where CODE is the key labeled CODE key Once this procedure was initialized by entering or CODE key all the keypad LEDs will turn OFF After entering the master code the keypad buzzer will sound 3 beeps confirming the system is being within master user s programming menu While the system is being within master user s programming menu the keypad LEDs status will be as follows ARMED A LED ON SYSTEM LED Blinking READY LED OFF zone LEDs OFF Note The master user s programming menu can be exited by key pressing When exiting the master user s programming menu the system will go back within disarmed status and the keypad LEDs will display the system and zone status There are several master user s submenus where the master user can perform the following operations
15. when one of the keys from 2 to 9 is pressed means that the system didn t reached that number of alarms during the last armed time and therefore there is the same global alarm information displayed as if 0 key was pressed 4 To visualize the special alarms press key again gt f LED 1 SYSTEM LED and READY LED are blinking then the alarm corresponding to the key pressed was triggered from keypad by pressing the key combination for Panic Fire or Medical Emergency gt If LED 2 SYSTEM LED and READY LED are blinking then the alarm corresponding to the key pressed was a keypad lockout alarm after too many wrong codes gt If LEDs 1 and 2 are OFF and SYSTEM LED and READY LED are blinking then the alarm corresponding to the key pressed was not triggered from keypad For a global view of special alarm triggered from keypad while within visualization menu of the special alarms press 0 key To go back to the global visualization menu for alarms triggered by 1 to 6 zones press key To exit alarm memory displaying menu press key The alarm memory will be cleared once the system partition is armed again A DIFFERENT DISPLAY METHOD FOR THE ALARM MEMORY AVAILABLE ONLY FOR KP 064EP KEYPADS lt gt in any order or both simultaneous where lt and gt are the scrolling keys gt displaying the next alarm and lt displaying the previous alarm Enter lt gt keys in any order or simultaneously
16. while the system is stay armed but this time the access through the delayed zones is allowed too for other users At the end of the exit delay time after such an arming mode the zones which usually are of the perimeter delayed type will maintain this feature if they are first violated during arming they will start the entry delay timer and will trigger the alarm only if a valid user code isn t entered until the entry time elapses Thus this arming mode is useful for the system partition arming during the night while the users can stay at home and other users which have own code may came back while the system is already armed While the green READY LED is ON or blinking in order to arm the system partition in stay mode simply key in a valid user code within one of the previous sequences For each key pressing the keypad buzzer will sound a short beep The user code must have the right of stay arming If after entering the last digit of the user code the keypad buzzer is sounding a long rejection beeps that means The user code was not correct press key and then key in again the user code within one of the previous sequences The user code hasn t the right of stay arming enter a user code with this right The user code is entered while the green READY LED is OFF all perimeter zones which don t allow forced arming feature must be closed when the system is stay armed The user code is entered w
17. will be as follows ARMED A LED ON SYSTEM LED Blinking READY LED ON 1 to 6 zone LEDs ON OFF according to the RIGHTS set of the modifying user code By key pressing RI GHTS set of the just modified user code can be maintained as it was previously established 4 1 In order to turn activate deactivate each right display able on 1 to 6 zone LEDs the you should press the 1 to 6 keys and the appropriate zone LED will turn ON OFF For selected user code if the a zone LED is ON means the appropriate right is enabled and if the zone LED is OFF means the right is disabled RI GHTS set for selected user code zone LEDs ON OFF zone 1 LED enabled disabled PGM1 activating deactivating zone 2 LED enabled disabled PGM2 activating deactivating zone 3 LED enabled disabled Access to partition A zone 4 LED enabled disabled Access to partition B zone 5 LED enabled disabled Starting the rounds zone 6 LED enabled disabled Finishing the rounds 4 2 Finally you should press key to confirm the RIGHTS set of the respective user code After 4 key pressing the keypad buzzer will sound 6 confirmation beeps and the control panel will go back within master user s programming menu 5 Erasure of selected user code except the master code can be performed by entering of key instead of sequence of 4 or 6 digits while the control panel just entered the programming erasing session of the corresponding selected user code The ke
18. Arming Keyswitch or Pushbutton Arming Disarming Quick Arming Modes Arming without user codes Away Quick APMINg cce cece e eee cette ee eee tenn eae ena ce TT E Dick Instant Stay ATTICI o iere tae er eC Ce One cus pe FUP ys deg E ed XP ERR e p Cota QR ERE TEE OE WERE Mia FUSE OU TE ERE EE UEUAE MECU Pe Eee eee eee eee PY TED CHS Eau NCPDWAQ Vos oes o oce ocu o Pb CR A PLC ain a ab woh Soh abre a Ra o T E psit oO rus cue eot em e orar UH VN e Ed Disarming amp Deactivating an Alarm Meriana da ota Cus ert uod Les Zone bypassing exc science cae asalre cea ao vie ede uite Died B ie alice wie Diele Gi x ict n e Ra e ob asin We eee di n Boc e ede t Dd ait u s ae i i i d ui e x D e System Trouble Status Displaying 4 comand Alarm Memory Displaying 5 A different display method for the alarm memory available only for KP O64EP keypads sssssssssesm meme 19 Chime Feature activatirig deaclivalifit ie ee cere peser e Free ee Ce TET ONT PEOR Ee galee Let EXE E Fe tte UE PTS PRO E RE e CU E ES DUE FA TRES E Qn Y ge 20 Activation Deactivation of PGM Outputs Starting Finishing the ROUNGS cc memes memes ems nene nnn 20 Master User s Programming Menus eesesesesesesesesenunununu unu na n s ER ER RR RR GR GR SRSXSSRSRHHHAGIG4XRXRs4 s 4 ga gag aaa dese sasasasasasasasu sana sa sanas nu na nana Programming Selective Erasure except the master code of 01 to 45 User Cod
19. C power loss events occur in the system Phone line tone detection upon the automatic initiating the voice messages reporting Using the MPV8 voice module up to 8 voice messages 2 4 or 8 specific to different alarm types to the AC power loss event and to the armed or disarmed system status can be reported upon remote interrogation calls or to the follow me phone numbers e In case of no MPVS8 the panel will report upon remote interrogation calls or to the follow me phone numbers synthesis sounds Up to 4 follow me phone numbers for the control panel to automatic report on the phone line the alarm and AC power loss events by specific voice messages or by specific synthesis sounds MISCELLANEOUS Zone tamper activates BELL output when system is disarmed programming option in section 20 In case of system armed and zone tamper recognition enabled zone tamper conditions activates BELL output Real clock timer which will stamp the 400 events in LOG Quick arming options away quick arming quick stay arming and quick instant stay arming allowed by programming Options of arming by users away arming stay arming and instant stay arming allowed by user rights Autoarming options timed autoarming and inactivity autoarming allowed by programming Option the system or each partition independently automatically switches to stay arming mode after any regular arming by user by PC
20. Cerber C62 6 Zone and 2 Partition Burglary Control Panel For your home and office Doc 10401 08 08 2005 version 1 9 1 2 3 4 PNTRODUCTIOON P General Features User Codes pes de SAL dude OE da Utere DA us VASE ANGE Codes QC ERR RNEOENES Di itali CONE ETE co MEERMREHMC T er Ec 4 Upload Download PGM functions Poet CE Monitoring of system troubles Voice messages synthesis sounds Communicator Miscell eouS A ee e ety riina EE aa eed Wen EEE ont VEETEE AAE ENKA E EEN Ee E EEE EAEE EE ENEA a Ea tice euch ish AAEE nied dd H EN Technical ecin ele io morren raana TET 6 KEY d oc A T T a DL IUUD T T A T Keypad types Keypad layout ead siga aue AEN NU UTR AE js Functional Keys cere e oe et Pres EC FREE UE ERO UE ERE GO ETHER HERE DU FOE Uw eed ne ered a RETE RUE ee eT RE ee Be XS EG OPERATION System codes s ESTRE PR EE RI EE ROUEN E T Installer S COMES nC EE 10 Partitioning Nile tid aida E ENA cs afe TRA AWE une soos eos ERROR Lp Wwovcv PcT RM Other ATI MOSS assicura E cete Pen ta a Rte wena P Red K eae e Tama este eere ER RN ERE SETA NL CA MERECE E SERM ARE TREE MERERI vehement Timed Autoarming Inactivity Autoarming Instant Stay Arming Stay Arming Switch To Stay
21. F only after a successful transmitting to both CS1 and CS2 Zone 3 LED System time and date not The control panel s internal clock must be re programmed because the programmed control panel was powered This trouble indicator will turn OFF only after programming the system time and date The system time and date are Zone 4 LED 17 Power ON necessary for correct recording of the events into the 400 event LOG This trouble indicator will appear if wiring between the siren and the control panel is shorted cut off or there is an overload on the siren control wire a 2k2 resistor must be connected across the bell terminals An overload on the siren control wire is detected only during when a condition has occurred which would activate the bell output e g during an alarm The BELL output uses a fuseless circuit and it will automatically shut down if the current exceeds 2 5A After opening the short cut or reducing the load the bell current is restored automatically Zone 5 LED Bell Trouble If the Telephone Line Monitoring TLM feature is enabled see section 28 Zone 6 LED Phone line trouble TLT this trouble indicates that the control panel has not detected the presence of a telephone line for 30 seconds Press key to exit system trouble displaying menu Please note that the keypad is programmed to emit intermittent beeps at every 8 seconds whenever a trouble condition occ
22. Section 87 Moment for Starting the Rounds Hour Minute 11 Section 88 Moment for Finishing the Rounds Hour Minute 12 Section 89 Round Period Warning round time 13 Section 90 Inactivity Time after that the control panel will auto arm Hours Minutes 14 Section 97 Manually Activation of PC callback 15 Section 98 Manually Activation of Communication with PC PC download acceptance 16 Section 99 Cancellation of the voice sound reporting and the communication between panel and PC Notes 1 2 Master user s entering of these commands is similar to the entering the same programming sections which are dedicated to the installer After the master user enter 8 Master Code command if he is trying to select another programming section than the previous then the keypad buzzer will sound a long error beep and the panel will reject the command If the digital communicator was enabled by the installer and the corresponding reporting codes was programmed too then any accessing of main programming menu by the master user will be transmitted to CS as follows In case of any 4x2 formats was set by the installer the control panel will transmit to CS the same specific reporting codes regarding programming entry programming exit panel programming changed events which are set in 61 and 62 sections even the respective operations were performed by the master user or by the installe
23. TEM LED will stop to blink only upon another system partition arming After the exit delay elapsed the READY LED will turn OFF and the red ARMED A LED will keep fast blinking until Disarming signaling the system is perimeter and instant armed while the system was armed in instant stay mode the zone which are usually of the perimeter delayed type will respond as the instant ones Because during such an arming period the access into the building isn t allowed through the zones which usually are of delayed type at least a user must remain inside the building to disarm the system partition Notes 1 n a partitioned system in order to arm a partition in an instant stay mode by users assigned to only one partition simply key in a valid user code within one of the previous sequences the corresponding partition will instant stay arm 2 In a partitioned system in order to arm a partition in an instant stay mode by users assigned to both partitions simply key in a valid user code within one of the previous sequences the zone 1 and 2 LEDs will flash for 5 second allowing the 13 user to choose the partition partitions to be armed by pressing 1 and or 2 keys The selected partition partitions will instant stay arm STAY ARMING 2 User Code or STAY User Code where STAY is the key labeled STAY This method is also useful for perimeter protection and it allows the users to remain in the protected area
24. TO 4 FOLLOW ME PHONE NUMBERS 7 Master Code 5X Phone number X or CODE Master Code 5X Phone number X where CODE is the key labeled CODE key and X is the 1 to 4 order number for the 4 follow me phone numbers which can be programmed by the master in this submenus The 7 Master Code 5X Phone number X or CODE Master Code 5X Phone number X commands allow to the master user to program selective erase the follow me phone numbers Notes 4 The follow me phone numbers denomination will be used for the phone numbers which the control panel will automatic dial them upon occurring in the system of some alarm and AC power loss events to report these events and the system status too by voice messages or by synthesis sounds specific to these events 5 Up to 4 follow me phone numbers can be programmed by the master user for the control panel to automatic report on the phone line the alarm and AC power loss events by specific voice messages or by specific synthesis sounds While the system is being within master user s programming menu in order to program erase any of the 1 to 4 follow me phone numbers select the corresponding submenu from 51 to 54 by entering one of the groups 51 52 53 or 54 enter 51 to select the 1 follow me phone number 52 for the 2 one and so on While the system is being within programming session of the selected phone number the keypad LEDs
25. X overload AUX overload Restore System time and date Loss System time and date Reprogrammed Keypad lockout Cancellation of reporting to CS may be performed only by installer UPLOAD DOWNLOAD Several upload download operations Uploading the system parameters from control panel onto PC actually onto EZcom C62 Software Downloading the programming of system parameters from PC actually from EZcom C62 Software onto the control panel PC programming using EZcom C62 Software Uploading the event LOG from the control panel into the EZcom C62 Software actually in a file System time and date setting by PC actually by EZcom C62 Software System or partitions arming Disarming from PC actually by EZcom C62 Software Zone bypassing by PC actually by EZcom C62 Software PGM activation deactivation by PC only for PGM outputs defined as mono stable bi stable or clock timer types Online visualization of the system partitions status and troubles onto EZcom C62 Software Online visualization of the bypassed alarmed or open zones onto EZcom C62 Software Programmable callback function with up to 3 attempts automatic or manually activation manually activation may be performed by master or by installer 400 event LOG with upload and visualizing possibility through the EZcom C62 Software and optionally reported to CS Option of automatic answe
26. amming Cerber C62 will send a reporting code to the central station and or a phone voice message according to the occurrence of one of the next events Panic Fire Medical Emergency and Maintenance Request These events occur by activating the correspondingly 24h defined zones or by simultaneously pressing a combination of keys from keypad 1 3 Medical Emergency alarm 7 9 Fire alarm 4 6 Maintenance Request Panic alarm In order to stop any alarm status enter key followed by any 4 or 6 digit user code from 1 to 45 Note The keypad panic alarm should be used in emergency situations when the user is threatened and the possible offender must not be notified about sending the respective message In this case the keypad panic alarm should be set of the silence type you should see section 21 System OPTI ONS zone 6 LED 30 WARNING LIMITATIONS OF ALARM SYSTEMS Although this is an advanced design security system it doesn t offer guarantees warning not protection against burglary fire or other emergency Any alarm system whether commercial or residential is subject to compromise or failure to warn for a variety of reasons For example Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor or disconnect an alarm warning device Intrusion detectors i e passive infrared detectors smoke detectors any other se
27. ave been assigned as follows entering of such a code while siren is sounding and the partition is armed will disarm the partition but the siren will not be stopped if there are zones from the other partition which triggered alarm first entering of such a code while siren is sounding and the partition is disarmed will stop the siren sounding only if the alarm was triggered by zones from the same partition to which the code have been assigned if first entering of such a code couldn t stop the siren sounding then next entering of code will can t to arm the partition until the siren stops to sound 2 if the a user is assigned to both partitions the siren will stop sounding automatically and then the zone 1 and 2 LEDs will flash for 5 second allowing the user to choose the partition partitions to be armed disarmed by pressing 1 and or 2 keys 16 ZONE BYPASSI NG 3 User Code or BYPASS user code where BYPASS is the key labeled BYPASS Zone bypassing is necessary in case of a faulty detector or troubleshooting isn t being allowed because of faulty wiring where the system needs to be armed altogether and access is desired in a zone even with system armed Zone bypassing can be performed only while the system is partially armed and if the zones allow manually bypassing see manually bypassing attribute of zones into 01 to 06 sections The control panel will no longer consider the detectors from a bypassed zone Armin
28. but no access to the master user s functions System parameters can be programmed using this code through 8 Installer s programming code command only when the control panel is disarmed For system parameter programming to be accomplished only by authorized people this code must be changed after the system was installed 2 The installer s maintenance code not programmed by default this code may have the same 11 rights as the 1 to 45 user codes but has no access to the programming menu of the system parameters and to the master user s functions Using this code the installer can arm disarm the system partition and in urgent situations he can bypass the faulted zones Please note that the installer can disarm the system partition using maintenance code only if the system partition was previously armed by the same code installer s maintenance code PARTI TI ONI NG The CERBER C62 is equipped with a partitioning feature which can divide the alarm system into two distinct areas identified as partition A and partition B Partitioning can be used in installations where shared security systems are more practical such as a home office or warehouse building If the system is not partitioned all user codes and features will be recognized as belonging to the system doesn t mater if user codes have the right of access to partition B or zones are manually assigned to partition B HOW DOES A PARTI TI ONED SYSTEM WORK Users can only arm d
29. code The user code hasn t the Disarming siren stopping right enter a user code with this right After entering the last digit of a valid user code the ARMED A LED will turn OFF and the keypad buzzer will sound 3 confirmation beeps of system partition disarming If at least one alarm occurred during the previous arming period then after Disarming the SYSTEM LED will stay blinking until the next arming To visualize the first 9 alarms occurred in the system since last arming use 5 command If no alarms occurred during the previous arming period and the SYSTEM LED is still blinking after Disarming see system trouble status by means of 4 command TO DEACTI VATE AN ALARM SIMPLY KEY IN ANY USER CODE 4 OR 6 DIGITS WHILE THE SIREN IS SOUNDING The user code must have the siren stopping Disarming right if the siren sound is stopped while the system is armed then the system will disarm too If the siren sound is stopped while the system is disarmed then only the siren will stop to sound without system arming In the second case if the user wants to arm the system after the siren sound was stopped he must key in again the user code In a partitioned system entering a user code with the right of siren stopping while siren is sounding will function as follows 1 if the a user is assigned to only one partition it can stop the siren sounding only if the alarm was triggered by zones from the same partition to which the code h
30. d all status LEDs will turn OFF except the ARMED which will remain ON until Disarming signaling the system is away armed Remark before system partition arming the users should check the following 1 If the READY LED is OFF means there is in the system at least one violated zone which doesn t allow forced arming feature those zones have disabled by programming their forced arming attribute Since the system cannot be armed if the READY LED is OFF all loops of those protected zones need to be closed while system partition arming doors and windows should be closed people in rooms protected by PIR detectors must go away etc 2 Please note that READY LED may be blinking while there are violated zones in the system the LEDs of violated zones are lit too That means the respective zones allow forced arming feature and they allow system partition arming although the zones are violated at the very moment of arming In this case the user should check if the zones that allow forced arming feature are the same ones established by the installer 3 If the SYSTEM LED is lit then the user should check if the zones that the system will bypass during the next arming period are the same ones bypassed by himself using 3 User Code or BYPASS User Code commands 4 Ifthe SYSTEM LED is blinking check the following o The alarm memory by means of 5 command if there are alarms in the memory the alarm memory will be cleared once
31. d siren output with positive trigger PNP current capability on BELL typically 1A 2A maximum fuse less electronic shutdown at 2 2A automatic restore Note Current capability and protections for the auxiliary power supply AUX and for the bell control output BELL as well are valid only if the control panel is powered both from the AC source 220Vac and the backup battery too 2 KEYPADS Within protected area you can install up to 4 keypads one for each and every entry exit door KEYPAD TYPES The next keypads are available KP 064P keypad with 6 zone LEDs and 4 status LEDs KP O64EP keypad with 6 zone LEDs 4 status LEDs and scrolling keys KEYPAD LAYOUT ARMED BYPASS 4 2 3 sm SYSTEM READY oo 4 6 Es ZONE2 ZONE3 7 l 8 J 9 sr ZONE4 ZONES ZONEG J 0 J cove KP 064P KP 064EP Description of LEDs meaning according to the system status READY LED a While the system is totally armed OFF b While the system is partially armed e ON the system is ready for arming all zone loops are closed even those which allow forced arming feature e Blinking the sys
32. e mono stable as bi stable or as clock timer the user should press 2 key and the zone 2 LED will turn ON OFF If the zone 2 LED is ON means PGM2 is activated and if the zone LED is OFF means PGM2 is deactivated Any successful command of PGM2 activation deactivation is followed by an automatic exit from menu after about 1 second like after key pressing after 1 sec 4 In order to manually start finish the rounds the user should press 6 key and the zone 6 LED will turn ON OFF If the zone 6 LED is ON means the rounds are being into progress and if the zone LED is OFF means the rounds were finished Any successful command of starting finishing the rounds is followed by an automatic exit from menu after about 1 second like after key pressing after 1 sec Notes a Incase one user is trying to activate deactivate the PGM outputs or is trying to start finish the rounds and the respective user code hasn t the right enabled then the keypad buzzer will sound a long error beep and will reject the respective command b The keypad buzzer will sound a long error beep and the panel will reject the command too if users try to activate deactivate any PGM output which was not set as retriggerable or resetable mono stable as bi stable or as clock timer even if the respective user code has the right enabled by programming c Ifthe digital communicator is enabled by programming and the appropriate reporting codes are programmed too
33. e exit delay timer will start and the red ARMED A LED will turn fast blinking In the same time the control panel will automatically bypass the interior zones the zones inside the objective that have the stay attribute activated by programming the zones that have not the stay attribute activated are called perimeter zones If the buzzer warnings were enabled by programming then during the exit delay the keypad buzzer will sound warning beeps During the exit delay the yellow SYSTEM LED will light as follows ON in case at least one interior zone is going to be bypassed by the panel and or at least one zone was previously bypassed by the users the yellow SYSTEM LED will turn OFF only when Disarming Blinking in case there are troubles in the system AC power loss low voltage on battery fail to communicate event BELL trouble phone line trouble or system time and date loss the yellow SYSTEM LED will stop to blink only after all troubles in the system will be solved Alternating 3 seconds ON 3 seconds blinking in case both conditions are met in the same time there are in the system troubles and zones bypassed too by the users and or by the panel If during any home arming period at least one alarm or trouble occurs in the system then the SYSTEM LED will start to blink Because the alarm memory is cleared only upon another system partition arming then after at least one alarm occurred the yellow SYS
34. e of the phone number the control panel will go back within master user s programming menu only after key pressing 4 In order to erase the selected phone number you should enter key instead of sequence of maximum 15 digits while the control panel just entered the corresponding programming erasing session of the selected phone number The keypad buzzer will sound 6 confirmation beeps and the control panel will go back within master user s programming menu after pressing key was enter Any follow me phone number from 1 to 4 can be selected in order to get a new value or press X key to exit the master user s programming menu Program the 1 Follow me Phone Number 7 Master Code 51 Phone number 1 or CODE Master Code 51 Phone number 1 Program the 2 nd Follow me Phone Number 7 Master Code 52 Phone number 2 or CODE Master Code 52 Phone number 2 7 Program the 3 rd Follow me Phone Number 7 Master Code 53 Phone number 3 or CODE Master Code 53 Phone number 3 Program the 4 th Follow me Phone Number 7 Master Code 54 Phone number 4 or CODE Master Code 54 Phone number 4 7 SELECTI VE ERASURE OF THE FOLLOW ME PHONE NUMBERS 1 7 Master Code 5X or ICODE Master Code 5X where CODE is the key labeled CODE key and X is the 1 to 4 order number for the 4 follow me phone numbers which can be erased by the master using these command
35. ection 23 Qui ck STAY ARMING O 2 This arming type is similar to stay arming by user code Note Quick stay arming is allowed only if the appropriate option is enabled by programming see the option displayable on zone 3 LED within programming section 23 DISARMING amp DEACTIVATI NG AN ALARM User Code x x x x or x x x x x x In order to disarm an already armed system or to deactivate an alarm the users should enter the protected area through any delayed zone and simply key in a valid user code 4 or 6 digits Once a delayed zone is first violated during one arming period it will start the appropriate entry delay timer the keypad buzzer will sound a continuous beep indicating that the system must be disarmed The system will not generate the alarm until the entry time elapses giving to the user enough time to enter the premise and to disarm the system totally or partially to modify the entry delay times see section 37 Enter any of the 1 to 45 user codes 4 or 6 digits to disarm the system partition The user code must have the Disarming siren stopping right After entering the first code digit the continuous beep will stop and upon each key pressing the keypad buzzer will sound a short beep If after entering the last digit of the user code the keypad buzzer is sounding a long rejection beeps that means The user code was not correct press key and then key in again the user
36. elected user code you should enter the following sequence from the keypad x x x x for 4 digit codes or x x x x x x for 6 digit codes where x x x x and x x x x x x are the new 4 or 6 digits for the selected user code 2 1 After entering the first digit of a new sequence for selected user code the zone 2 LED will be blinking That means the control panel is waiting for second digit for the new value of the selected user code 2 2 After entering second digit of the selected user code the zone 3 LED will be blinking That means the control panel is waiting for the third digit for the new value of the selected user code and so on until entering the last digit of the selected user code the forth for 4 digit codes and the sixth for 6 digit codes 2 3 After any digit was pressed programming of the selected user code may be canceled by key pressing After cancellation by key pressing the keypad buzzer will sound 6 confirmation beeps the system will keep the old value for the selected user code and the control panel will go back within master user s programming menu Note Do not press key while entering the digits of the selected user code The keypad buzzer will sound a long error beep and will reject key 3 After entering the last digit of the selected user code the keypad buzzer will sound 3 confirmation beeps and the panel will pass to the next step displaying on zone 1
37. ere are in the system troubles and zones bypassed too by the users and or by the panel If during any home arming period at least one alarm or trouble occurs in the system then the SYSTEM LED will start to blink Because the alarm memory is cleared only upon another system partition arming then after at least one alarm occurred the yellow SYSTEM LED will stop to blink only upon another system partition arming After the exit delay elapsed the READY LED will turn OFF and the red ARMED A LED will keep slow blinking until Disarming signaling the system is stay armed Any user can get inside the building 14 through the delayed zones and he she must enter own user code 1 to 45 until the entry time elapses in order to disarm the system partition Notes 1 n a partitioned system in order to stay arm a partition by users assigned to only one partition simply key in a valid user code within one of the previous sequences the corresponding partition will stay arm 2 In a partitioned system in order to stay arm a partition by users assigned to both partitions simply key in a valid user code within one of the previous sequences the zone 1 and 2 LEDs will flash for 5 second allowing the user to choose the partition partitions to be armed by pressing 1 and or 2 keys The selected partition partitions will stay arm SWITCH TO STAY ARMING After any regular arming by user by PC or by keyswitch if during exit delay no entry exit zo
38. es Simultaneous Erasure of all users codes except the master code sssssss Programming Selective Erasure of the 1 to 4 follow me Phone Numbers Selective Erasure of the follow me phone numbers ssesssseseenes Maie Pneu vba equ tidie dinde ea FERE Simultaneous Erasure of all Follow me Phone Numbers 2 0 meme eeh mese mese meses se sese enne eme nennen sense nennen Programming session of the system time and date EE eme se seme see mese nemen nene nen n nnns Ambush Digit Programming master user s submenu 61 Vea vim visere xd Utd tiv a Fia wn Other Operation Commands Performed by the master user ssssssssssssssesesse emm seems seems semen ene mene mene nnn nnn PC dawnlgad accepEanice Sars semene pne ttu xk ne wie Lond ag a Re a dee ro atre La leue ai a Tex Or E ra ea rv e Ba x Di dum e c Oe ea ara le b a RERO ERU E ER Voice Sound Reporting and Communication with PC Cancellation E ate ba bead MA ul ied 3 Keypad Special alattie e Ero Dedi nes one Pis rest E en voy EMERY ES Qu Enn narii apa E cr err AC ERO to Ye nn es epos d y eine BE ue e REN Warning Limitations of Alarm Systems ivsedscnstwaadses em etn ra ta d ede da e aae na D rx paura tunt p pap Ream sins n pR OA aaae ia aie E eee ienie ie fd 1 INTRODUCTION GENERAL FEATURES Central unit s core of powerful RISC microprocessor The electrical features include an EEPROM memory for the programmed configuration
39. fficient warning to allow all occupants to escape in time to prevent injury or death Passive Infrared Motion Detectors can only detect intrusion within designed ranges as diagrammed in their installation manual Passive Infrared Detectors do not provide volumetric area protection They do not create multiple beams of protection and intrusion can only be detected in unobstructed areas covered by the beams They cannot detect motion or intrusion that takes place behind walls ceiling floors closed doors glass partitions glass doors or windows Mechanical tampering masking painting or spraying of any material on the mirrors windows or any part of the optical system can reduce detection ability Alarm warning devices such as sirens bells or horns may not alert people or wake up sleepers who are located on the other side of closed doors If the warning devices sound on a different level of the residence from the bedrooms then they are less likely to waken or alert people inside the bedrooms Even persons who are awake may not hear the warning if the alarm is muffled by noise from a stereo radio air conditioner or other appliances or by passing traffic Finally alarm warning devices however loud may not warn hearing impaired people or waken deep sleepers Telephone lines needed to transmit alarm signals from premises to a central monitoring station may be out of service or temporarily out of service Telephone lines are also subject to co
40. follows Keypad LEDs LEDs Status Remarks ARMED A LED ON SYSTEM LED Blinking READY LED ON That means the selected user code was programmed during a previous programming Zone 1 2 and 3 LEDs Blinking session 22 While the system is being within programming erasing session of the selected user code the keypad LEDs status will be as follows Keypad LEDs LEDs Status Remarks That means the selected user code isn t programmed and the control panel Only zone 1 LED Blinking waiting for the first digit for the new value of the selected user code One of the 2 to 4 zone LEDs or to 6 Blinking for 6 digit codes That means the selected user code is programming and the control panel waiting for the corresponding digit for the new value of the selected user code 1 Programming Erasing of the selected user code may be skipped by key pressing 1 1 After key pressing if the selected user code was programmed during a previous programming session then the keypad buzzer will sound 3 confirmation beeps and the system will pass to display the first 5 rights of the selected user code step no 3 1 2 After key pressing if the selected user code wasn t programmed during a previous programming session then the keypad buzzer will sound 6 confirmation beeps and the control panel will go back within master user s programming menu 2 In order to program the s
41. g can be performed with one or more bypassed zones even if the sensors on these zone loops are faulted I n order to enter zone bypassing menu the user should enter one of the commands 3 User Code or BYPASS user code Once this procedure was initialized by entering or BYPASS key all the keypad LEDs will turn OFF After entering the user code the keypad buzzer will sound 6 confirmation beeps and the SYSTEM LED will blink If some zones were previously bypassed the respective zone LEDs will be ON too If no zones were previously bypassed the all zone LEDs will be OFF To bypass a zone press the key which corresponds to the zone number and the appropriate LED will turn ON To un bypass any zone press the corresponding key while the appropriate zone LED is ON then the corresponding zone LED will turn OFF Press key to exit zone bypassing menu Once at least one zone was bypassed the SYSTEM LED will turn ON and it will stay lit until cancellation of all 6 zone bypassing or until system Disarming Note Bypassed zone status is only valid during a single arming period upon system Disarming bypassed zone status will be automatically cleared by the panel SYSTEM TROUBLE STATUS DISPLAYING 4 COMAND The CERBER C62 continuously monitors six possible trouble conditions When a trouble condition occurs the SYSTEM LED will turn blinking Press 4 keys to switch within trouble display menu after entering key al
42. g within certain sections of programming menu of the system parameters FUNCTIONAL KEYS Functional Keys STAY BYPS INST CODE and lt gt only for keypad KP 064EP are functionally only while the system is partially armed if pressed while system is total armed the keypad buzzer will sound a long rejection beep STAY It is used for system perimeter arming stay arming or instant stay arming BYPS BYPASS It is used for zone bypassing INST It is used for instant stay arming or for system partition arming without code INST CODE CODE It is used for system partition arming without code or to program modify the user codes the follow me phone numbers or the system time and date lt amp gt only on KP 064EP They are used to display the first 9 alarms occurred in the system since last arming 3 OPERATION A KP 064P KP 064EP The keypad is the device that helps with system programming entering commands and data as well as displaying the system status System operation is performed using the keypad and the LED indications on the frontal side of the keypad The keypad has 6 zone LEDs and 4 status LEDs ARMED A ARMED B READY and SYSTEM The LED indications will be detailed throughout this manual SYSTEM CODES The system recognizes 2 special installer s codes installer s programming code and installer s maintenance code and 45 user codes
43. hasn t the right of arming enter a user code with this right The user code is entered while the green READY LED is OFF all zones which doesn t allow forced arming feature must be closed when the system is armed The user code is entered while the green READY LED is blinking but the code hasn t the right of force arming all zones must be closed when the system is armed by such a user code After entering a valid user code all keypad LEDs will be ON for a little while and the keypad buzzer will sound 6 acceptance beeps Then the exit delay timer will start and the red ARMED A LED will turn ON The users must exit the premise through an entry exit point until the exit delay elapses If the buzzer warnings were enabled by programming then during the exit delay the keypad buzzer will sound warning beeps During the exit delay the yellow SYSTEM LED will light as follows ON in case at least one zone was previously bypassed by the users Blinking in case there are troubles in the system AC power loss low voltage on battery fail to communicate event BELL trouble phone line trouble or system time and date loss Alternating 3 seconds ON 3 seconds blinking in case both conditions are met in the same time there are in the system troubles and zones bypassed by the users too 11 The default exit delay time is 60 seconds see the section 38 of the main programming menu After the exit delay elapse
44. he PGM1 output by pressing 1 key PGM1 status is displaying on zone 1 LED activation deactivation of the PGM2 output by pressing 2 key PGM2 status is displaying on zone 2 LED Manually start finish the rounds by pressing 6 key the status of rounds is displaying on zone 6 LED Notes 1 The PGM1 and PGM2 activation deactivation commands are allowed only if these outputs are defined as retriggerable or resetable mono stable bi stable or clock timer types 2 Any PGM1 or PGM2 output as retriggerable mono stable set will activate to GND for the time lapse set within 22 and 80 programming sections If a new command is performed while this PGM type is being active then the respective time lapse will be triggered again 3 Any PGM1 or PGM2 output as resetable mono stable set will activate to GND for the time lapse set within 22 and 80 programming sections If a new command is performed while this PGM type is being active then the respective PGM will turn OFF 4 Any PGMI or PGM2 outputs as bi stable set will change its status from activate to deactivate and the other way round upon each entering a new activating deactivating command 5 Any PGMI or PGM2 outputs as clock timer type set upon entering new start stop command of PGM activation period will change the PGM status from activated to deactivated and vice versa depending if the respective PGM activation period was previously started or
45. hile the green READY LED is blinking but the code hasn t the right of force arming all perimeter zones must be closed when the system is stay armed by such a user code After entering a valid user code within one of the previous sequences all keypad LEDs will be ON for a little while and the keypad buzzer will sound 6 acceptance beeps Then the exit delay timer will start and the red ARMED A LED will turn slow blinking In the same time the control panel will automatically bypass the interior zones the zones inside the objective that have the stay attribute activated by programming the zones that have not the stay attribute activated are called perimeter zones If the buzzer warnings were enabled by programming then during the exit delay the keypad buzzer will sound warning beeps During the exit delay the yellow SYSTEM LED will light as follows ON in case at least one interior zone is going to be bypassed by the panel and or at least one zone was previously bypassed by the users the yellow SYSTEM LED will turn OFF only when Disarming Blinking in case there are troubles in the system AC power loss low voltage on battery fail to communicate event BELL trouble phone line trouble or system time and date loss the yellow SYSTEM LED will stop to blink only after all troubles in the system will be solved Alternating 3 seconds ON 3 seconds blinking in case both conditions are met in the same time th
46. hm to function with central stations which generate handshake frequencies in any order and kiss off time from 0 6 to 3 seconds Many communicator formats DTMF Ademco Contact ID and several 4x2 formats 10PPS 20PPS 40PPS and DTMF Ademco Express Programmable data and handshake frequency and transmission speed in 4x2 format Ademco Express 10PPS 20PPS or 40PPS with parity no parity data of 1800 or 1900 Hz and handshake of 1400 or 2300 Hz Periodical test reporting with steps of up to 255 minutes or hours time adjustment of the starting and either unconditionally reporting or only while armed status Programmable reporting codes for zone alarming zone restore and zone bypassing automatic from swinger or by the panel during home arming periods if the zones have the attribute stay and manually by the users Programmable zone restore the zone restore event is recorded either in real time for each violated zone when the violated zone closed back or upon bell cut off for all zones that previously triggered the alarm Programmable reporting codes for Arming Disarming Ambush events according to the user code Programmable reporting codes for system trouble situations Low battery voltage Restore battery voltage AC power loss AC power Restore Bell Trouble upon disconnection or overload on the siren Bell trouble Restore Restore of disconnection or overload on the siren AU
47. isarm partitions to which they have been assigned A user assigned to both partitions can arm disarm the both partitions Entering such a user code in a partitioned system is followed by a time of 5 seconds in which the zone 1 and 2 LEDs are flashing allowing the user to choose the partition to be armed disarmed to arm disarm the partition A the user must pres 1 key and to arm disarm the partition B the user must pres 2 key Only zones assigned to partition A will arm disarm when partition A is armed or disarmed Only zones assigned to partition B will arm disarm when partition B is armed or disarmed A zone assigned to both partitions is armed only if both partitions are armed and it is disarmed if at least one partition is disarmed Some of the system s features can be programmed separately for each partition REGULAR AWAY ARMING User Code x x x x or x x x x x x This method commonly used for day to day arming will arm all zones in the system While the green READY LED is ON or blinking in order to arm the system partition in away mode simply key in a valid user code 4 or 6 digits For each key pressing the keypad buzzer will sound a short beep The user code must have the right of arming If after entering the last digit of the user code the keypad buzzer is sounding a long rejection beeps that means The user code was not correct press key and then key in again the user code The user code
48. isplayable on zone 5 LED within 20 section While the system is being within master user s programming menu in order to program the system time and date the master user should select 60 submenu While the system is being within master user s programming session of the system time and date the keypad LEDs status will be as follows Remarks ARMED A LED ON SYSTEM LED Blinking READY LED ON zone 1 2 and 3 LEDs Blinking That means the system time and date were programmed during a previous programming session Only zone 1 LED Blinking That means the system time and date are not programmed and the control panel is waiting for the first 2 digit group which represents the day D D That means the system time and date is being programmed and the control One of the 2 to 6 zone LEDs Blinking panel is waiting for the corresponding 2 digit group for month Mo Mo year Y Y hour H H minutes Mi Mi or seconds S S 1 Programming of the system time and date can be canceled by key pressing 2 In order to enter programming session of the system time and date the master user should introduce the format bellow D D Mo Mo Y Y H H Mi Mi S S Each 2 digit group represents the day D D month Mo Mo year Y Y hour H H minutes Mi Mi and seconds S S 2 10nce the first 2 digit group corresponding the day D D was entered the keypad buzzer will sound 3 beeps and the zone 2 LED is blinking That means the contr
49. ividually programmable within master s programming menu using 7 Master Code or CODE Master Code commands Zone bypassing Regularly arming Stay arming Force arming Disarming siren stopping PGM1 activating deactivating PGM2 activating deactivating Access to partition A Access to partition B Starting the rounds Finishing the rounds Note The control panel is provided with protection against valid code guessing attempts If the option of keypad lockout after too many wrong codes is enabled then the keypad lockout counter will be counting the successive attempts of entering wrong access codes see the option of keypad lockout after too many wrong codes which is displayable on zone 1 LED within 20 section in case the successive attempts of entering wrong access codes gets the value set within section 44 the keypad will lock for 7 minutes and all the keypad LEDs will fast blink The event will be memorized into the 400 event LOG which can be uploaded and viewed onto PC by EZcom C62 Software and optionally a specific reporting code will be transmitted to CS too if the digital communicator is enabled by programming and the appropriate reporting code is programmed within 58 or 69 section I NSTALLER S CODES The system installer owns 2 codes 1 The installer s programming code 0269 by default which has total access to the programming menu of the system parameters
50. l the keypad LEDs will turn OFF then after entering 4 key the SYSTEM LED will blink and each trouble condition will be signaled to the corresponding zone LED as follows ZONE LEDs DESCRIPTION DETAILS The control panel performs a dynamic battery test every 32 seconds This trouble indicates that the battery is disconnected or its voltage is lower than Zone 1 LED Low voltage on battery 11 5 volts Please note the backup battery is continuously charged while AC power is present and if this trouble persists for a long time that means the battery must be replaced If AC power is missing the transformer is burnt or the fuse near the Zone 2 LED AC power loss transformer is burnt this trouble indicator is ON and it will turn OFF once the AC power restored This trouble indicator will be ON when after the 8 attempts for both CS phone numbers the control panel failed to transmit to the central station none of the CS answers even after the 8 call in case of the alternate reporting was selected The LED will Fail to communicate turn OFF only after a successful transmitting to CS event A the control panel failed to transmit events to CS1 after 8 attempts 1 CS phone number will not answer either after the 8 call and or the control panel failed to transmit events to CS2 after 8 attempts 27 CS phone number will not answer either after the 8 call in case of the split reporting was selected The LED will turn OF
51. mpromise by sophisticated intruders even if the system responds to an emergency as intended occupants may however have insufficient time to protect themselves from the emergency situation In case of a monitored alarm system authorities may not respond appropriately The most frequent cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance This alarm system should be tested weekly to make sure that all sensors work properly 31 TECHNI CAL SPECIFI CATI ONS Zone number 6 zones Zone type programmable EOL Resistor 3 3kOhm 2EOL Resistors 2 2kOhm and 1kOhm Programmable outputs PGM1 and PGM2 2 Maximum load for PGM1 and PGM2 outputs 50mA Main board typical consumption 50mA LED keypad typical consumption 12mA Maximum power current for battery charging200mA Board operation rated voltage 13 8 14Vdc ROEL electronics S A innovating email sales roel ro WWW roel ro Calimachi Street 27 29 023496 Bucharest ROMANIA I oe Tel 4 021 204 47 00 Fax 4 021 242 20 30 p 32
52. ne is violate user doesn t leave the protected area through any entry exit point the system partitions automatically switches from regular arming to stay arming if the appropriate option is set as enabled in 26 and or 27 sections KEYSWITCH OR PUSHBUTTON ARMING DISARMING Connecting a keyswitch or a push button to any zone programmed as stay keyswitch or keyswitch type then these can be pressed to stay or regular arm and disarm the system Ifthe system is ready and the button is pressed the system will arm Pressing the button again will disarm the system In a partitioned system the keyswitch or push button will arm disarm the partition which has assigned the respective stay keyswitch or keyswitch zone Note in case the stay keyswitch or keyswitch zone is assigned to both partitions and the keyswitch or push button is pressed while one partition is armed and the other is disarmed then the armed partition will first disarm and only pressing the button again will arm the both partitions Qui ck ARMING MODES ARMING WITHOUT USER CODES Quick arming features allow the system to be quickly armed by any person who may not own a user code The users can also use these arming modes while system needs to be armed in the presence of someone who isn t to find out the user code In a partitioned system entering any of quick arming commands is followed by a time of 5 seconds in which the zone 1 and
53. nication with PC modem which should be already on the phone line and call the control panel Voice SOUND REPORTING AND COMMUNICATION WI TH PC CANCELLATION 8 Master Code 99 This command allows to the master user to stop the voice sound reporting and communication between panel and PC The command will be accepted only if the system is disarmed Notes 1 This command is the same as the one described within programming section 99 which is dedicated to the installer with the exception that the master user can only stop the voice sound reporting and the communication between panel and PC without stopping the digital communication between control panel and central station 2 When any alarm occurs just entering a user code the master code included will only disarm the system partition and or stop the siren sound without cancellation of the voice message sound dialing 3 n order to stop the voice message sound dialing in case an alarm was triggered and the voice sound dialer has already started the reporting of the voice messages to the follow me phone numbers first users should disarm the system partition and or stop the siren sound by any valid user code then the master user should enter 8 Master Code 99 command Please note that the cancellation of the voice sound reporting is allowed only to the master user not to the users from 2 to 45 KEYPAD SPECIAL ALARMS Depending on the installer progr
54. nsing devices will not work without power Battery operated devices will not work without battery with dead battery or if the battery are not properly put in Devices powered solely by AC will not work if their AC power supply is cut off for any reason even for a short period of time A user may not be able to reach a panic or emergency button quickly enough Smoke detectors may not activate or provide early warning for a variety of reasons Some of the reasons why smoke detectors used in conjunction with this system may not work are as follows gt Smoke detectors may have been improperly installed and positioned Smoke detectors may not sense fires that start where smoke cannot reach the detectors such as chimneys in walls or roofs or on the other side of closed doors Smoke detectors may not sense a fire on another level of a residence or building A second floor detector for example may not sense a first floor or basement fire Moreover smoke detectors have sensing limitations No smoke detector can sense every kind of fire every time In general detectors may not always warn about fires caused by carelessness and safety hazards like smoking in bed violent explosions escaping gas improper storage of flammable materials overloaded electrical circuits children playing with matches or arson Depending on the nature of the fire and or the location of the smoke detectors the detector even if operating as anticipated may not provide su
55. number or the system time and date were programmed during a previous programming session That means the selected user code the follow me phone number or the system Only zone 1 LED Blinking time and date are not programmed and the control panel is waiting for the first digit group for respective option PROGRAMMING SELECTIVE ERASURE EXCEPT THE MASTER CODE OF O1 TO 45 USER CODES 7 Master Code or CODE Master Code where CODE is the key labeled CODE The 7 Master Code or CODE Master Code commands allow to the master user to modify all the user codes except the installer s codes While the system is being within master user s programming menu in order to program erase any of 01 to 45 user codes the master user should select the corresponding submenu from 01 to 45 by pressing the 2 digit order number of the user code to be programmed erased i e while the system is being within master user s programming menu for user code no 15 press 1 and 5 keys Then enter the following sequence x x Lx Lx or x x x x x x for 6 digit codes RIGHTS RIGHTS 7 where x x x x and x x x x x x are the new 4 or 6 digits for the selected user code and RIGHTS amp RIGHTS are 1 amp 2 sets of rights for selected user code While the system is being within programming erasing session of the selected user code the keypad LEDs status will be as
56. ol panel is waiting for second 2 digit group corresponding the month Mo Mo 2 10nce second 2 digit group corresponding the month Mo Mo was entered the keypad buzzer will sound 3 beeps and the zone 3 LED is blinking That means the control panel is waiting for the third 2 digit group corresponding the year Y Y 27 2 10nce the third 2 digit group corresponding the year Y Y was entered the keypad buzzer will sound 3 beeps and the zone 4 LED is blinking That means the control panel is waiting for the fourth 2 digit group corresponding the hour H H 2 10nce the fourth 2 digit group corresponding the hour H H was entered the keypad buzzer will sound 3 beeps and the zone 5 LED is blinking That means the control panel is waiting for the fifth 2 digit group corresponding the minutes Mi Mi 2 10nce the fifth 2 digit group corresponding the minutes Mi Mi was entered the keypad buzzer will sound 3 beeps and the zone 6 LED is blinking That means the control panel is waiting for the sixth 2 digit group corresponding seconds S S 2 10nce the sixth the last 2 digit group corresponding seconds S S was entered the keypad buzzer will sound 6 confirmation beeps and the control panel will go back within master user s programming menu 2 1 After any digit was pressed system time and date setting can be canceled by key pressing After cancellation by key pressing the keypad buzzer will sound 6 confirmation beeps and the contr
57. ol panel will go back within master user s programming menu keeping the old value for the system time and date 3 Leave the master user s programming menu by 7 key pressing AMBUSH DIGIT PROGRAMMING masTER USER S SUBMENU 61 7 Master Code 61 or CODE Master Code 61 where CODE is the key labeled CODE While the system is being within master user s programming menu in order to program the ambush digit the master user should select 61 submenu While the system is being within programming session of the ambush digit the keypad LEDs status will be as follows Remarks ARMED A LED ON SYSTEM LED Blinking READY LED ON Zone 2 to 6 LEDs OFF Zone 1 LED Blinking That means the control panel is waiting for the ambush digit to be programmed 1 Programming of the ambush digit can be canceled by key pressing 2 In order to establish the ambush digit you should enter any digit from O to 9 by pressing the corresponding key Once any digit from O to 9 was entered the keypad buzzer will sound 6 confirmation beeps and the control panel will go back within master user s programming menu 3 Leave the master user s programming menu by key pressing Notes 1 The default value for the ambush digit is 0 2 Do not press key while the system is being within programming session of the ambush digit because the panel will record wrong codes and
58. or 27 sections The autoarming time is programmed using the 24 hour clock i e 8 00PM 20 00 as described in 85 and 86 sections INACTIVITY AUTOARMI NG If inactivity autoarming option is enabled within 26 and or 27 sections and the control panel does not detect any movement zone openings for a specified period the panel will arm the system partitions Please note as with regular arming the system partitions will not auto arm if a zone is violated and force autoarming is not enabled or if the zone doesn t allow forced arming If this occurs the control panel will report fail to auto arm code and the system partition will not arm for a new inactivity time The type of autoarming is regular or stay and is dependent on the appropriate options within 26 and or 27 sections Program the inactivity autoarming time as it is described in 90 section I NSTANT STAY ARMING 1 User Code or INST STAY User Code where INST and STAY are the keys labeled INSTANT and STAY This method is useful for perimeter protection and it allows the users to remain in the protected area while the system is instant stay armed At the end of the exit delay time after such an arming mode the zones which are usually of the perimeter delayed type will respond as the instant zones they will 12 trigger the alarm as soon as they will be violated Thus any user can stay inside the protected area bu
59. r whether these operations are performed by the installer or by the master user there will be no difference between them in 4x2 formats In case of CID format 4 account digits 4 event digits 2 partition digits 3 zone user digits was set by the installer the control panel will transmit to CS the specific reporting codes regarding programming entry programming exit panel programming changed which are set in 72 and 73 sections after the 4 digit group specific to these reporting events the panel will transmit to CS another 3 digit group which stands for the master user or for the installer identifying In CID format the installer is identifying as user 000 and the master user as user 001 PC DOWNLOAD ACCEPTANCE 8 Master Code 98 This command allows to the master user to manually trigger the communication between PC and panel Before entering this command the modem of PC must be already on the phone line and call the control panel While PC modem is calling the control panel just entering this command will manually activate the communication between PC and panel This command is accepted only while the system is partially armed Notes 1 This command is similar to the one in the installer dedicated programming section 98 2 Manually triggering of the communication between PC and panel is useful when Panel answers to remote PC calls option was not enabled by programming in section 33 which
60. rload on AUX trouble though it does record as LOG event and optionally if the digital communicator is enabled by programming and the appropriate reporting code is programmed too it is reported to CS cannot be displayed on the keypad because the keypad is powered exactly from this power supply and an overload on AUX is stopping keypad powering until overload gets removed 2 If any trouble condition occurs it needs to be solved before arming to assure a proper function for the system 3 If there are alarms in the memory the SYSTEM LED will turn blinking too if the SYSTEM LED is blinking just because of at least one alarm occurred since last arming you can see the first 9 alarms occurred in the system since last arming then by means of 5 command ALARM MEMORY DISPLAYING 5 The first 9 alarms occurred in the system since last arming are memorized and they can be visualized on zone LEDs To view the alarmed zones or the special alarms triggered from the keypad enter 1 5 keys while the system is partially armed Once this procedure was initialized by entering key all the keypad LEDs will turn OFF After entering 5 key the SYSTEM LED and the Zone LEDs which triggered the alarm will light as follows steady ON if the appropriate zone has generated at least one alarm during the last armed period flashing if the appropriate zone has generated at least one zone tamper alarm ON 2 seconds followed by fla
61. rs to PC calls either after double call or after programmable number of rings Manually activation of communication with PC PC download acceptance performed by master or by installer Communication between PC and panel Cancellation performed by master or by installer ZONES 6 End of line resistor zones entirely programmable as delayed instant follower 24 hour burglary fire tamper panic medical emergency arming Disarming keyswitch or round type n u 12 zone attributes individually programmable as audible silent alarm steady pulsing siren manually bypassing auto shutdown forced arming chime function activating stay n u intellizone sensor under test as well as individually selectable zone response time Zone bypassing automatic from swinger or by the panel during home arming periods if the zones have the attribute stay and manually by the users 2 real partitions which can be armed disarmed independently from each other allowed by user rights Individually programmable exit and entry delay times for each partition allowed by programming Programmable alarm type silent or audible and for the audible alarms steady or pulsing Individual siren timers for burglary and fire alarms PGM FUNCTI ONS 2 programmable outputs each with 31 options Panic alarm latch Fire alarm latch Medical emergency alarm latch Latch on tamper alarm
62. s Erase the 1 follow me phone number 7 Master Code 51 or CODE Master Code 51 Erase the 2 follow me phone number 1 7 Master Code 52 or CODE Master Code 52 26 Erase the 3 follow me phone number 7 Master Code 53 or CODE Master Code 53 Erase the 4 follow me phone number 1 7 Master Codej 54 4 or CODE Master Code 54 where CODE is the key labeled CODE SIMULTANEOUS ERASURE OF ALL FOLLOW ME PHONE NUMBERS 7 Master Code 50 or CODE Master Code 50 where CODE is the key labeled CODE While the system is being within master user s programming menu to simultaneous erase all follow me phone number select the corresponding submenu 50 by entering 5 and 0 keys The keypad buzzer will sound 6 confirmation beeps and the control panel will go back into master user s programming menu Any follow me phone number from 1 to 4 can be selected in order to get a new value or press X key to exit the master user s programming menu PROGRAMMI NG SESSI ON OF THE SYSTEM TI ME AND DATE 7 Master Code 60 D D Mo Mo Y Y H H Mi Mi S S or CODE Master Code 60 D D Mo Mo Y Y H H Mi Mi S S where CODE is the key labeled CODE Note The system time and date programming is allowed to the master user only if the appropriate option does not disabled by programming see the option d
63. se there are troubles in the system b While the system is partially armed Blinking in case there are recorded alarms during the previous arming period or during that Disarming period for 24h zones or there are troubles in the system AC power loss low voltage on battery fail to communicate event BELL trouble phone line trouble or system time and date loss ON in case there is in the system at least one zone bypassed by user Alternating 3 seconds ON 3 seconds blinking in case both conditions are met in the same time there is in the system at least one zone bypassed by user and there are in the system troubles and or recorded alarms since last arming Blinking when the user is being within one of the next menus Zone bypassing System trouble displaying Alarm memory displaying or Program Modify of the user codes follow me phone numbers or system time and date Blinking while the installer is being within programming menu of the system parameters ARMED A LED a While the partition A or the system is armed ON if the partition A or the system is totally armed Fast Blinking if the partition A or the system is armed in instant stay mode Fast Blinking during any arming period after any delayed zone which belongs to the partition A or to the system triggered the alarm Slow Blinking if the partition A or the system is armed in stay mode b While the partition A or the system is disarmed
64. shing 2 seconds and repeating this sequence if the appropriate zone has generated both alarm conditions zone alarm and zone tamper alarm 18 To view the special alarms triggered from the keypad press key again The green READY LED will also fast blink indicating the special alarms on the LEDs 1 and 2 Within visualization menu of special alarms LED 1 indicates an alarm triggered from keypad panic fire medical emergency and LED 2 indicates a keypad lockout alarm after too many wrong codes Exit the visualization of special alarms by pressing key again Press the keys from 1 to 9 to view the order of the first 9 alarms occurred in the system since last arming By pressing 1 key you can see the 1 alarm and by pressing 9 key you can see the 9 alarm Note LED interpretation in case of pressing a key from 1 to 9 is accordingly performed 1 If the LED corresponding to one of the 1 to 6 zones is blinking SYSTEM LED is blinking and READY LED is OFF then the alarm corresponding to the key pressed occurred on zone whose LED is blinking E g If 8 key is pressed and the zone 3 LED is blinking then the 8 memorized alarm was triggered by zone 3 2 If all LEDs corresponding to zones 1 6 are OFF SYSTEM LED is blinking and READY LED is OFF then the alarm corresponding to the key pressed hasn t been triggered by any zones 3 If more than one zone LED lights steady ON flashing or the combination of these two
65. t no one should come in from outside for example this arming mode is useful for the system partition arming during the night when the users are going to sleep and expect no guests thus entry exit points like doors and windows are armed while other zones like motion detectors remain deactivated While the green READY LED is ON or blinking in order to arm the system partition in an instant stay mode simply key in a valid user code within one of the previous sequences For each key pressing the keypad buzzer will sound a short beep The user code must have the right of stay arming If after entering the last digit of the user code the keypad buzzer is sounding a long rejection beeps that means The user code was not correct press 4 key and then key in again the user code within one of the previous sequences The user code hasn t the right of stay arming enter a user code with this right The user code is entered while the green READY LED is OFF all perimeter zones which don t allow forced arming feature must be closed when the system is stay armed The user code is entered while the green READY LED is blinking but the code hasn t the right of force arming all perimeter zones must be closed when the system is stay armed by such a user code After entering a valid user code within one of the previous sequences all keypad LEDs will be ON for a little while and the keypad buzzer will sound 6 acceptance beeps Then th
66. tem is ready for being armed all zone loops are closed but not those which allow forced arming feature e OFF at least one zone is open only those without attribute forced arm activated c While the system is partially armed and finds itself within one of the Programming Menus e ON while the master user is programming modifying the user codes the follow me phone numbers or the system time and date e ON while the installer is being within one of the system parameter programming sections d While the system is being armed during the exit delay e ON if all zone loops stay closed even those which allow forced arming feature e Blinking if all zone loops stay closed but not those which allow forced arming feature SYSTEM LED A While the system is armed in regular mode OFF armed in home mode Blinking in case there are recorded alarms during that home arming period and or there are troubles in the system AC power loss low voltage on battery fail to communicate event BELL trouble phone line trouble or system time and date loss ON in case there is in the system at least one zone bypassed by user and or if there is at least one interior zone bypassed by the system Alternating 3 seconds ON 3 seconds blinking in case both conditions are met in the same time there are troubles and or recorded alarms and zones bypassed too in the system During any exit delay time Blinking in ca
67. the first user code being the master code 1234 by default All the user codes have the ambush code capability and the installer s maintenance code too USER CODES The master code 1 user code is programmed 1234 by default Using the master code you can operate the system and modify delete the other user codes The allowed operations for the master code are Arming Disarming Zone Bypassing Un bypassing Programming Erasing of the user codes Programming Erasing of the follow me phone numbers System time and date Setting Cancellation of the voice sound reporting and the communication between panel and PC PC download acceptance The 2 to 45 user codes not programmed by default Allowed operations Arming Disarming and Zone Bypassing Unbypassing All user codes have ambush capability by pressing the key which corresponds to the ambush digit before the 4 or 6 digits of any user code then the control panel will transmit a special code to the central station by a phone line or by a G S M module if the control panel is connected to a central station That means that user was under duress ambush Thus the dispatcher will be signaled that the user action was performed under threat In order to program the user codes the master code included the master user will use one of the 7 Master Code or CODE Master Code commands Each of 1 to 45 user codes has 11 rights ind
68. then the ambush capability of the user codes will not function any more OTHER OPERATI ON COMMANDS PERFORMED BY THE MASTER USER Some of programming sections which are dedicated to the installer are accessible to the master user too In order to access these programming sections you should use 8 Master Code command while the system is partially armed Once the command was entered the master user should enter each allowed section by pressing the corresponding 2 digits i e for 81 section he should enter 8 and 1 keys Then the master user should program the corresponding parameters or to start finish the corresponding process in the same mode explained in the respective section of the main programming menu The programming sections allowed to the master user are 28 1 Section 32 OPTIONS for voice sound dialer 2 Section 46 Number of voice or sound dialing sequences Time of the Voice or Sound Reporting 3 Section 78 Walk Test service mode 4 Section 81 Activation Moment of PGM1 as clock timer Hour Minute 5 Section 82 Deactivation Moment of PGM1 as clock timer Hour Minute 6 Section 83 Activation Moment of PGM2 as clock timer Hour Minute 7 Section 84 Deactivation Moment of PGM2 as clock timer Hour Minute 8 Section 85 Autoarming Moment for the partition A or system Hour Minute 9 Section 86 Autoarming Moment for partition B Hour Minute 10
69. to 5 LEDs the RI GHTS set of the just modified user code as follows While the system is being within RI GHTS displaying submenu the keypad LEDs status will be as follows ARMED A LED ON SYSTEM LED Blinking READY LED ON 1 to 5 zone LEDs ON OFF according to the RI GHTS set of the just modified user code By 4 key pressing RIGHTS set of the just modified user code can be maintained as it was previously established 3 1 In order to turn activate deactivate each right display able on zone 1 to 5 LEDs you should press the 1 to 5 keys and the appropriate zone LED will turn ON OFF For selected user code if the a 23 zone LED is ON means the appropriate right is enabled and if the zone LED is OFF means the right is disabled RI GHTS set for selected user code zone LEDs ON OFF zone 1 LED enabled disabled Zone bypassing zone 2 LED enabled disabled Regular arming zone 3 LED enabled disabled Stay arming zone 4 LED enabled disabled Force arming zone 5 LED enabled disabled Disarming siren stopping zone 6 LED reserved reserved 3 2 Finally you should press key to confirm the RIGHTS set of the respective user code 4 After 4 key pressing the keypad buzzer will sound 3 confirmation beeps and the panel will pass to the next step displaying on 1 to 6 zone LEDs the RIGHTS set of the modifying user code as follows While the system is being within RIGHTS displaying submenu the keypad LEDs status
70. urs for the first time Stopping the actual intermittent beeps can be released by system partition arming or by any entering within trouble displaying menu by pressing the 4 Keys So as soon as the users had acknowledged the troubles by means of 4 command the keypad trouble buzzer warnings will stop as there are no troubles in the system but the corresponding trouble indicator will still remain ON until the respective trouble condition is solved The SYSTEM LED will still remain to blink until all the troubles will be solved If next trouble beep stopping option is enabled by programming it can be released just by entering command 4 as follows once user entered 4 command if the keypad buzzer will sound 6 confirmation beeps that means in the future the keypads will no longer emit intermittent beeps upon any new trouble occurring the intermittent beeps will not be reactivated even a new trouble will occur once user entered 4 command if the keypads emits no beeps that means in the future the keypads will emit again intermittent beeps upon any new trouble occurring the intermittent beeps will be reactivated whenever a new trouble occurs or the trouble has restored and re occurred So if next trouble beep stopping option was enabled by programming then any entering within trouble displaying menu will toggle the next trouble beep emitting from activated to deactivated and vice versa Remarks 1 Ove
71. ying the 1 alarm and you press key the control panel will go back within global visualization menu for 19 alarms triggered by 1 to 6 zones and will keep displaying this global menu You can press a key from 1 to 9 any time for the system to display the alarm corresponding to the key pressed Next if key is pressed the system will display the previous alarm until displaying the global menu CHI ME FEATURE ACTI VATI NG DEACTI VATI NG 6 Chime feature activating deactivating can be performed only if the system is disarmed by entering the command 6 If the feature is got activated the keypad buzzer will beep for 3 times and if it is got deactivated the keypad buzzer will sound a long beep While system is disarmed once the chime feature was activated each time when a zone with chime attribute is opened will cause the keypad buzzer to sound 6 warning beeps The feature is useful if the entry exit doors are out of the user s view and he she wants to be notified whenever the doors of those zones are opened Chime feature can be activate deactivate from PC software too ACTIVATION DEACTIVATION OF PGM Outputs STARTING FINISHING THE ROUNDS 9 User Code If a user code maintenance code included has the appropriate rights enabled by programming then the respective user may use 9 User Code command and perform the following operations activation deactivation of t
72. ypad buzzer will sound 6 confirmation beeps and the control panel will go back within master user s programming menu after pressing key was enter Notes 24 1 The master code has all the rights enabled by default and they are programmable only by the installer If master code was select to be programmed after entering the last digit of the master code the keypad buzzer will sound 3 confirmation beeps and the control panel will pass within master RIGHTS displaying submenu on zone 1 to 5 LEDs All zone LEDs from 1 to 5 will be ON or OFF as the respective rights were established by the installer previously the master rights cannot be changed by him That means if master user is trying to change his rights by pressing any key from 1 to 5 the keypad buzzer will sound a long error beep and the control panel will reject the command In order to pass to the next step and displaying on zone 1 to 6 LEDs the RIGHTS set the master user needs to press key 1 to 6 zone LEDs will be ON or OFF as the respective rights were established by the installer previously neither this master rights can be changed by him too In order to exit the master user s programming menu the master user needs to press key again So the master user can change his own code by means of 7 Master Code 01 command he may view his rights but he cannot change himself his rights The master user only may see own rights as they were established by the installer