Home
Product User Manual - Gerling Applied Engineering, Inc.
Contents
1. Product User Manual Model GA1108 3 Port Circulator 5 8 GHz CPR159 Document 930047 Rev 1 Gerling Applied Engineering Inc P O Box 580816 Modesto CA 95358 www 5800mhz com Product User Manual Page 2 Model GA1108 3 Port Circulator 5 8 GHz CPR159 REVISION HISTORY REV DESCRIPTION DATE APPROVAL 1 PROTOTYPE RELEASE 15JANO4 JFG WARRANTY Products manufactured and sold by Gerling Applied Engineering Inc GAE are warranted to be free of defects in materials and workmanship under normal use and service for a period of twelve 12 months from the date of original shipment GAE s obligation under this warranty is limited to repairing or replacing at GAE s option all non consumable component parts Consumable parts are specifically excluded from this warranty and may include but are not be limited to magnetrons fuses lamps seals o rings v belts and fluids All warranty repairs are to be done at GAE s facility or as otherwise authorized by GAE All shipping charges for warranty repair or replacement are the purchaser s responsibility unless otherwise agreed to by GAE This warranty supercedes all other warranties expressed or implied No warranty is given covering the product for any particular purpose other than as covered by the applicable product specifications GAE assumes no liability in any event for incidental or consequential damages finan
2. the GA1108 3 port circulator will operate without any need for operator involvement No adjustments or settings are available or necessary CAUTION Care must be taken to avoid operating the microwave generator at power levels exceeding the rating of the 3 port circulator Excessive power levels can cause damage to the ferrite disks and or magnets Isolation A measure of the minimum attenuation of power between the input port and the unintended output port Insertion Loss A measure of the maximum attenuation of power as it passes through the device Input VSWR A measure of maximum reflection VSWR at the input port due to incident power only assumes no reverse power leaving the same port Note that these parameters are often measured and specified by the manufacturer at low power operation Because of the thermal effects due to power absorption the actual performance can vary from the manufacturer s specifications when the device is operated at high power or in the presence of high VSWR It is also important to note that performance is dependent on the phase relationships between forward and reverse power at any one port Performance specifications are typically given for the worst case phase relationships 2004 Gerling Applied Engineering Inc Modesto CA Product User Manual Page 10 Model GA1108 3 Port Circulator 5 8 GHz CPR159 MAINTENANCE The GA1108 3 port circulator is designed to b
3. cial losses penalties or other losses incurred in conjunction with the use of GAE products DOCUMENT CONVENTIONS NOTE Means the reader should take note Notes contain helpful information suggestions or references to other sections chapters or documents CAUTION Means the reader should be careful You are doing something that might result in equipment damage or loss of data WARNING Means danger A situation exists that could cause bodily injury or death All personnel must be aware of the hazards involved with high voltage electrical circuitry and high power microwave devices ppi 2004 Gerling Applied Engineering Inc Modesto CA Product User Manual Page 3 Model GA 1108 3 Port Circulator 5 8 GHz CPR159 WARNING All 3 port circulators manufactured by GAE Inc are intended for use with other equipment capable of producing a microwave field that is potentially hazardous to operating personnel They must never be connected or operated in a manner that allows a field in excess of 10 milliwatts per square centimeter to be generated in an area accessible to operating personnel Contact GAE Inc for technical support prior to installation and or operation of these units if there is any question or concern about microwave leakage All waveguide flange and electrical cable connections throughout the system must be secure prior to operation Never operate the microwave generator without a properly rated absorbi
4. d used with any common waveguide component having a compatible flange see below The mounting position can be either horizontal or vertical but the orientation with respect to the microwave generator depends on the intended function The most common function of a 3 port circulator is that of an isolator for protection of a magnetron from the damaging effects of reverse power This configuration requires a separate dummy load such as GAE model GA1221 connected to port 3 Port 1 is then connected to the microwave generator and port 2 is oriented towards the process load Figure 1 below illustrates the circulator used in a typical isolator configuration MICROWAVE GENERATOR CIRCULATOR D ECTIONAL COUPLER TUNE SHORT CIRCUIT T ERMINATION Figure 1 Typical isolator waveguide configuration CAUTION Because the 3 port circulator relies on a magnetic field for operation care must be taken to avoid placing the device near other sources of strong magnetic fields For similar reasons 2004 Gerling Applied Engineering Inc Modesto CA Product User Manual Page 8 Model GA1108 3 Port Circulator 5 8 GHz CPR159 the 3 port circulator should be located at least 4 inches from other metal objects that respond to magnetic fields i e ferrous steel Flange Connections m All three flanges of the 3 port circulator must be properly connected to another waveguide component Bo
5. e maintenance free and does not require any user maintenance under normal operating conditions No calibration is necessary Although the GA1108 3 port circulator is a very rugged and stable device it can be subject to damage due to excessive power levels or mishandling If damage occurs the circulator should be returned to GAE for repair Contact GAE for information on repair services 2004 Gerling Applied Engineering Inc Modesto CA
6. lts must be installed at all flange bolt holes on both flanges and securely tightened prior to operation Microwave Leakage Regulatory limits for microwave leakage relate to standards for human safety and interference with other electronic devices Standards for human safety as adopted by OSHA the International Electrotechnical Commission IEC and other regulatory agencies limit leakage to 5 mW cm measured at 5 cm from the leakage source under normal operating conditions and 10 mW cm at 5 cm from the source under abnormal operating conditions The U S Federal Communications Commission FCC has established regulations limiting the emission of energy at frequencies outside the ISM bands All GAE waveguide components meets these requirements when properly connected to another waveguide component O 2004 Gerling Applied Engineering Inc Modesto CA Product User Manual Page 9 Model GA1108 3 Port Circulator 5 8 GHz CPR159 OPERATION Basic Operation A Performance Considerations Ideally all of the power entering the 3 port circulator typically through port 1 will exit through only one of the other two ports typically port 2 In practice however a small amount of power is absorbed by the circulator and or reflected back to the source and a small amount of power exits the other output port port 3 Thus the following parameters are commonly used to measure the performance of a circulator Once installed
7. ng load attached To ensure safe operation and prevent microwave leakage the equipment must be periodically inspected and maintained as required or recommended 2004 Gerling Applied Engineering Inc Modesto CA Product User Manual Page 4 Model GA 1108 3 Port Circulator 5 8 GHz CPR159 TABLE OF CONTENTS EQUIPMENT DESCRIPTION ti 5 General Specifications 5 Outline Drawing 6 INSTALLATION 7 Preliminary Inspection 7 Waveguide Configuration 7 Flange Connections 8 OPERATION A a 9 Basic Operation 9 Performance Considerations 9 MAINTENANCE Saa OIR e eS EEEE a 10 2004 Gerling Applied Engineering Inc Modesto CA Product User Manual Page 5 Model GA1108 3 Port Circulator 5 8 GHz CPR159 EQUIPMENT DESCRIPTION The model GA1108 3 port circulator is designed for high power industrial heating applications requiring high reliability and rugged construction These circulators are most often used with dummy loads such as model GA 1221 in an isolator configuration for magnetron protection but they are also useful in other configurations such as for constant frequency delivery of variable power see GAE Application Bulletin 960008 Construction of the GA1108 is primarily dip brazed aluminum waveguide Flange adapters are mounted to each port to accommodate the desired flange style The standard flange style is CPR F flat face while CMR and quick disconnect Q D cover flange styles are al
8. so available General Specifications Frequency 5 8 GHz nominal Input Power 700W continuous max fwd and rev Waveguide WR159 Input Flange CPR159F UG1731 U Input VSWR 1 1 max Port 1 Insertion Loss 0 15 dB max Port 1 to Port 2 Isolation 20 dB min Port 2 to Port 1 Construction Aluminum Finish Chemical conversion coating 2004 Gerling Applied Engineering Inc Modesto CA Product User Manual Page 6 Model GA1108 3 Port Circulator 5 8 GHz CPR159 Outline Drawing La 5 80 147 A ll 2 44 62 Y a I PORT PORT su 3 19 81 O Bn Sh eones FLANGE Q e UG1731 U 4 01 102 8X 1 4 20 UNC X 50 DP PORT 3 i 2004 Gerling Applied Engineering Inc Modesto CA Product User Manual Page 7 Model GA1108 3 Port Circulator 5 8 GHz CPR159 INSTALLATION Preliminary Inspection Upon arrival at the installation site the GA1108 3 port circulator should be thoroughly inspected for damage or wear caused during shipping Any visible damage to the packaging material or the circulator itself should be noted and reported immediately to the shipping company in accordance with standard claims procedures The following components are included a GA1108 3 port circulator b Product User Manual this document Waveguide Configuration A The GA1108 3 port circulator can be connected to an
Download Pdf Manuals
Related Search
Related Contents
Prime-Line R 7226 Instructions / Assembly Twist 397 User manual Sony DCR-VX700 Operation Manual SERVICE MANUAL TeCom-X5 UHF Manuale Palco-Rigolo plus Cisco Catalyst 3850 warning Copyright © All rights reserved.
Failed to retrieve file