Home

- Optical Vision Ltd

image

Contents

1. bottom of the hand control is used to set the SynTrek hand control to Northern or Southern Hemisphere operation The GO key is reserved for the use of future Sky Watcher products lt does not apply to the HEQ5 EQ6 SynTrek CS A LED light is installed in each key to indicate the status of the operation The LED will lit when a key is successfully pressed Once a key combination is entered all LEDs will lit to indicate successful operation Tracking an object In order for the SynTrek to properly track celestial objects the mount must be polar aligned first See the HEQ5 EQ6 mount instruction manual for procedures on how to polar aligned the HEQ5 EQ6 mount Once the power is turned on the automatically starts tracking by rotating the RA motor at the proper speed sidereal rate to compensate for the Earth s rotation The Dec motor does not automatically rotate If the mount is properly polar aligned little or no adjustment of the declination axis is necessary to track celestial objects Pressing the GUIDE key then SLOW key will stop tracking and allow the stars to drift by at their normal rotation rate Pressing the same key combination again will reactivate tracking The SynTrek provides the following three tracking options Sidereal rate tracking is the default tracking rate for the SynTrek It allows tracking of most celestial objects at the speed of the Earth s rotation rate Solar r
2. slewing and tracking control for the HEQ5 EQ6 mount The small and versatile SynTrek hand control provides automatic tracking of celestial objects as soon as the power is turned on The user friendly interface provides quick access to many other functions the has to offer Powering the SynTrek SynTrek can be turned on using the power switch on the HEQ5 or EQ6 mount The 5 SynTrek hand control cable has a RJ 45 connector to power supply on the ends Correctly plug it into the hand control outlet on the mount Push the connector into the outlet until it clicks into place Fig a The EQ6 SynTrek cable has DB9 connector on the end Plug the DB9 connector into the hand control outlet ED on the mount Tighten the screws to secure the connector in place Fig b Flip the Power Switch on EQ6 the mount to the on position to turn on the power power switch power indicator power switch Auto Guider S ynTrek hand control to power The SynTrek hand control Fig c has a simple interface of 9 push buttons The Guide Slow and Fast keys located near the top are used for setting the slewing and guiding speed The arrow keys allow complete directional control of the telescope during slewing or tracking The LEFT and RIGHT arrow keys are used to control movements in axis the UP and DOWN arrow keys are used to control the movements in Dec axis The Set key near the
3. INSTRUCTION MANUAL TABLEOF CONTENTS Introduction to the Syn Trek 222 Sse SSS RSS 3 Powering the 3 SynTrek hand control 45 2 nennen 3 Tracking an object 3 Slewing to an object 4 Selecting the slewing speed 4 Selecting the guiding speed 4 Reversing the direction 5 Setting for Northern Southern Hemisphere operation 5 Power saving oe 5 Technical specifications 6 Appendix Key combination quick reference guide i NEVER USE YOUR TELESCOPE TO LOOK DIRECTLY AT THE SUN PERMANENT EYE DAMAGE WILL RESULT USE A PROPER SOLAR FILTER FIRMLY MOUNTED ON THE FRONT OF THE TELESCOPE FOR VIEWING S THE SUN WHEN OBSERVING THE SUN PLACE A DUST CAP OVER YOUR FINDERSCOPE OR REMOVE IT TO PROTECT YOU FROM ACCIDENTAL EXPOSURE NEVER USE AN SOLAR FILTER AND NEVER USE YOUR TELESCOPE TO PROJECT SUNLIGHT ONTO ANOTHER SURFACE THE INTERNAL HEAT BUILD UP WILL DAMAGE THE TELESCOPE OPTICAL ELEMENTS Introduction to the SynTrek The SynTrek is designed for the purpose of providing a simple
4. Speed see Selecting the guiding speed on the next page Centering objects in the eyepiece 4X or 8X Centering objects in the finderscope 32X or 64X General fast slewing of the telescope 800X Selecting the guiding speed The SynTrek provides 4 speed settings equal to or slower than sidereal rate for guiding purpose 1X 0 75 0 5X and 0 25X These settings apply to both autoguiding via the autoguider interface and manual guiding The default guiding speed is 0 5X Once a new guiding speed has been selected the SynTrek will store the new setting until another speed has been chosen The following key combinations will set the guiding speed to the corresponding rate 1X Hold the FAST key then press the UP key 0 75X Hold the FAST key then press the LEFT key 0 5 Hold the FAST key then press the RIGHT key 0 25X Hold the FAST key then press the DOWN key Reversing the direction keys The direction a celestial object appears to move in the eyepiece changes depending on the type of telescope you are using and the accessories used in combination with the eyepiece This can be confusing when doing manual guiding To compensate for this the SynTrek offers a Reverse function to reverse the button logic of the hand control To switch between the LEFT and RIGHT key press and hold the SLOW key then press the LEFT key To switch between the UP and DOWN key press and hold the SLOW key then press the UP key Once t
5. THER SURFACE THE INTERNAL HEAT BUILD UP WILL DAMAGE THE TELESCOPE OPTICAL ELEMENTS
6. ate tracking allows SynTrek to properly track the Sun over a long period of time Solar rate tracking can be activated by pressing and holding the SLOW key then press the RIGHT arrow key Lunar rate tracking allows SynTrek to track the Moon at the same rate the Moon moves across the sky Lunar rate tracking can be activated by pressing and holding the SLOW key then press the DOWN arrow key 5 lewing to an object Selecting the slewing speed The GUIDE SLOW and FAST keys are used to select the speed at which the telescope moves when the arrow keys are pressed Once the speed is selected the LED of the corrisponding key will lit Flashing GUIDE SLOW or FAST indicates that the SynTrek is currently under the tracking mode Pressing the arrow keys will cause the SynTrek to move the telescope at the speed of the flashing key See the table below for details the speeds listed here are based on the Sindereal rate which is approximately 0 15 arc min sec D Solar rate tracking and Lunar rate tracking can only be activated while the telescope is already in the tracking mode To initiate Solar and Lunar rate tracking from non tracking mode first activate tracking then press the appropriate key combination for Solar or Lunar rate tracking RA movements When tracking mode is ON Guiding Speed When tracking mode is OFF Slewing speed recommendations 32X 4X 64X For manual guiding Guiding
7. e autoguiding operation the Dec motor will not enter the sleep mode again If you wish to initiate the power saving feature when the autoguiding operation is done press UP or DOWN arrow key to switch back to manual guiding The Dec motor will enter the sleep mode after 15 seconds shot to ensure picture quality If an autoguider is used wait until the autoguider sends the first Dec signal to the SynTrek before taking pictures TECHNICAL SPECIFICATIONS SynTrek SPECIFICATIONS Power Supply 11 to 15 V DC 2Amp Tip positive Motor type and resolution Microstep driven 1 8 stepper motors Resolution 0 144 arc sec or 9 024 000 steps rev Slewing speeds Guiding speed 4X 8X 32X 64X 800X Guiding speeds 1X 0 75X 0 5X 0 25X Gear Ratio 705 Tracking Rates Sidereal Lunar Solar Tracking Modes RA tracking APPENDIXA KEY COMBINATION QU CK REFERENCE GUI DE T saama EITC osram rm I Reverse RA direction keys SLOW then LEFT Reverse Dec direction keys SLOW then UP SynTrek NEVER USE YOUR TELESCOPE TO LOOK DIRECTLY AT THE SUN PERMANENT EYE DAMAGE WILL RESULT USE A PROPER SOLAR FILTER FIRMLY MOUNTED ON THE FRONT OF THE TELESCOPE FOR VIEWING THE SUN WHEN OBSERVING THE SUN PLACE A DUST CAP OVER YOUR FINDERSCOPE OR REMOVE IT TO PROTECT YOU FROM ACCIDENTAL EXPOSURE NEVER USE AN EYEPIECE TYPE SOLAR FILTER AND NEVER USE YOUR TELESCOPE TO PROJECT SUNLIGHT ONTO ANO
8. he direction keys have been reversed the setting will be stored even when the power is turned off Setting for Northern Southern Hemisphere operation The SynTrek comes set up for Northern Hemisphere operation In order for it to track correctly in the Southern Hemisphere you need to switch from the Northern to Southern Hemisphere operation mode by press down and holding the SET key while turning the unit on Release the SET key when the unit has successfully turned on and the GUIDE key starts flashing This needs to be done only once The SynTrek will operate in the Southern Hemisphere mode until it is switched back to Northern Hemisphere mode using the same method When the SynTrek is tracking under the Southern Hemisphere mode the SET key will flash as well as the GUIDE SLOW or FAST key see Fig e ES jects in the eyepiece view may appear to drift slightly in Dec direction the moment the Dec motor enters sleep mode When Power saving To conserve power assumption Dec motor enters sleep mode if idle for 15 seconds In this mode the Dec motor stops and the power supply current drops doing astro photography about 40 Pressing the UP or DOWN arrow key wait until the mount adjustment in Dec will reactivate the Dec motor If completely enters the sleep an autoguider is attached the signal it sends in Dec mode before beginning the direction will also reactivate the Dec motor In this case to accomodat

Download Pdf Manuals

image

Related Search

Related Contents

Introducción al uso de los Espacios Virtuales de ieRed: Manual de  LASER 900 inglese  LG Smart AC - smartThinQ  MICRO 6502 Journal, Volume 13, June 1979  Kingston Technology ValueRAM 8GB DDR3-1333  Avision AV 50F  EPP-201  Manuel d`utilisation BK-DVD-7895TV SOSP  Kobold2D v2.x Documentation  plaquette test&vous  