1. scroll the zoom in bar up to ruler scale as Lili shown on LCD screen This helps the camera contain the full viewing surface of transilluminator and gets the best image contrast Back Side Application NOTICE e AC power input Plug AC power cord and turn on the safety switch ON for utilization of Slider e USB port There are two ways to access the digital image file in the camera 1 Take out memory card in camera and read files with a card reader 2 Use USB cable type A male to A male to connect Slider USB port and PC The digital files in the camera will be automatically read by PC e AVterminal Terminal jack and switch for accessory of thermal printer With thermal printer connected with the AV terminal please turn switch ON for printing When printer is not in use please turn switch OFF Without thermal printer connected with the AV terminal please turn switch OFF for LCD normal display www maestrogen com TECHNICAL SUPPORT Maestrogen offers technical support for all of its products If you have any questions about the product s use or operation please contact Maestrogen at the following info 8275 South Eastern Avenue 200 LAS VEGAS NV 89123 USA E Mail info maestrogen com 12 www maestrogen com
2. your local Maestrogen office and inform Maestrogen of the model and serial number of your instrument REGULATORY NOTICE IMPORTANT This Maestrogen instrument is designed and certified to meet safety standards and EMC regulations Certified products are safe to use when operated in accordance with the instruction manual This instrument should not be modified or altered in any way Alteration of this instrument will 1 Void the manufacturer s warranty 2 Void the safety and EMC certification 3 Create a potential safety hazard www maestrogen com Maestrogen is not responsible for any injury or damage caused by the use of this instrument for purposes other than those for which it is intended or by modifications of the instrument not performed by Maestrogen or an authorized agent IMPORTANT NOTICE Please read the installation instruction carefully before installing the Slider Imager This instrument is intended for clinical and research laboratory use with DNA gel activation and it must be operated only by specialized personnel aware of the potential risks associated with the chemical and biological agents normally used with this unit This instrument is meant for use only by specialized personnel that know the health risks associated with blue light radiation and with reagents that are normally used with this instrument The amber filter provides some blue light protection However it does not guarantee complete protection and i
3. ddOoMRESTROGEN Slider Imager Instruction Manual Catalog Number SML 01 Version 01 10 www maestrogen com Hardware Instruction Manual This Slider Imager is suitable for research use only It must be used by specialized personnel that know the health risks associated with blue light irradiation and with the reagents that are normally used with this instrument Human naked eyes with long time irradiation of blue light may have the probability of suffering from retina diseases The amber filter provides blue light protection and is used for gel cutting However it does not guarantee complete protection It is designed to shield the person working at the Slider Imager only WARRANTY The Slider Imager is warranted against defects in materials and workmanship for 1 year If any defects occur in the instrument or accessories during this warranty period Maestrogen will repair or replace the defective parts at its discretion without charge The following defects however are specifically excluded 1 Defects caused by improper operation 2 Repair or modification done by anyone other than Maestrogen or an authorized agent 3 Damage caused by substituting alternative parts 4 Use of fittings or spare parts supplied by anyone other than Maestrogen 5 Damage caused by accident or misuse 6 Damage caused by disaster 7 Corrosion caused by improper solvent or sample For any inquiry or request for repair service please contact
4. he bands turn the imager off www maestrogen com Unpacking and Assembly Instruction Cut the tape and open the case Remove the bubble material at the top Remove the Slider Imager from the bubble material shells and place it on a stable horizontal surface as Fig 1 e Rotate the LCD adjustment to a suitable angle for observation as Fig 2 Place the camera fixation screw into the sidewall of the camera mount 2 screws for both sides as Fig 3 Use M2 Hexagonal screw driver to SLIGHTLY tighten the camera when the image on the LCD screen is exhibited with an acceptable horizontal as Fig 4 e To test the image horizontal of the camera place a card or paper with words or drawings on the gel supporting glass and turn on white light to adjust Mount Fig 1 Fig 2 ATTA RE Fe A N Fig 3 Fig 4 ah if www maestrogen com General Appearance of the Slider Imager LED transilluminator pushed in for photography LED transilluminator pulled out for gel cutting with amber filter www maestrogen com Front Panel of the Slider Imager ON OFF LED Transilluminator Power Switch Rear Panel of the Slider Imager Sav terminal USB port Power AC input Power AC input 1007240 V 50 60 Hz power source e USB port Use USB cable type A male to A male to connect imager and PC computer e Thermal printer AV terminal Composite video connector for thermal printer uti
5. lization www maestrogen com White Light Illumination in the dark box ON OFF White Light Illumination Power Switch Slider LED transilluminator and amber filter for gel cuttin in i i amp i LX i n k i mill z x i i cil Br ene w e Draw the transilluminator out with amber filter fixed on edge of it www maestrogen com LCD monitor and camera e LCD monitor ON OFF button mainly used Slider LCD Operating Instructions FdOMRESTROGEN Button Function Down Positive and Negative Adjustment Menu Activation of Menu Indicator UP Positive and Negative Adjustment POWER ON OFF Mode Selection and Display Area Enter button in function menu mode OFF gt Press and hold for about 3 seconds to turn off the power Down button Menu button Up button Power button Mode Selection When monitor is power on press button to change mode between V1 and V2 The real time display from digital camera is in one of the two channels Press and hold the ly button for 3 seconds the monitor power will be turned off Adjust Button the button will work when the monitor is in function menu mode Press adjust W 4 button to adjust the basic function reset all function and choose NTSC PAL mode in V1 or V2 mode 10 www maestrogen com e Camera Auto focus exposure time or shutter manually or automatically controlled If it is needed to zoom in
6. lls and place it on a stable horizontal surface 3 Remove the plastic protection film from the transparent glass viewing surface and the amber filter www maestrogen com Stand alone installation 1 The instrument must be placed on a bench leaving at least 10 cm of space all around in order to avoid any obstacle that may reduce the ventilation 2 Connect the instrument to the power using the annexed cable The power font must be able to deliver at least 250 VA with a voltage between 100 and 240 Vac The plug must have a ground connection GENERAL PRECAUTIONS Plug the imager on an electric line with ground connection The imager is equipped with thermal protection to prevent overheating Do not pour liquids directly on the imager Do not punch or collide the imager Switch off the instrument immediately after its use Position the imager to prevent harm to nearby operators The imager sample surface is a glass sheet for cutting gels When using the imager with samples stained with specific dyes decontaminate the glass surface with bleach Denatured alcohol can be also used Always wear disposable gloves Using the imager Place gel sample on the transparent glass support area It is recommended that gloves be worn to prevent skin contact with gel and staining agents Press the ON OFF switch to ON The LEDs within the unit will begin glowing under the glass support After taking photographs of the sample or cutting out of t
7. t is designed to shield only the person working in front of the system also to observe the DNA gel fluorescence emission clearly and perform gel cutting www maestrogen com SPECIFICATIONS Outline Dimensions mm 385 W x 415 D x 455 H Weight approx 20 kg Rated Voltage 100V 240V Fuse 1 25A Filter Amber filter Trans illumination LED 470 nm Viewing Size mm 160 x 200 Same as UltraBright LED transilluminator LB 16 Gel cutting filter Amber filter LCD 7 Wide TFT LCD 1 Display Area mm 180 72 H x 94 27 V 2 Number of Pixels 480 H x 3 RGB x 220 V 3 Aspect ratio 16 9 4 Brightness nits 250 Typ 5 Contrast Ratio 500 1 Typ 6 Blacklight Unit LED 7 Surface Treatment Anti Glare oOo no vr WN e 9 Digital camera 1 Effective pixel 12 2 M 2 Lens Fujinon 15x lens F3 1 Wide F5 6 Telephoto 3 Mode Program P Aperture Priority A Shutter Priority S Manual M 4 ISO Auto 100 200 400 800 1600 3200 6400 5 Video Output NTSC PAL selectable 6 Storage Media SD SDHC memory card 7 Storage Format JPEG ExifVer 2 2 10 LCD monitor rotation 0790 degree 11 USB port connect Slider and PC via USB cable 12 AV terminal thermal printer accessory compatible INSTALLATION Carefully unpack the Slider Imager as follows 1 First remove the bubble material at the top 2 Remove the Slider Imager from the bubble material she

Download Pdf Manuals

image

Related Search

Related Contents

Installation & Quick Start Guide  Manuel de l`opérateur  TECHKON SpectroPlate User Manual  Pneumatic locking cylinder ZLVS Operating instructions  Please read this Operation Manual Before you use the production.  一 〇このたびは、お買い上げいただきありがとうございます。 ご使用の前  Manuel utilisateur AC11005 AERFAST  表紙・関連情報 (PDF:3903KB)  く取扱説明書) ペット体重計 KK-5G  