Home

CAPTIVE PURITY

image

Contents

1. psi LIMITED WARRANTY Bayside Aquarium Supply Inc warrants each new Reverse Osmosis amp Deionization system to the original owner only to be free from defects in material and workmanship under normal use and conditions for a period of 90 days from the date of original purchase Bayside s liability under this warranty shall be limited to repairing or replacing on Bayside s option without charge F O B Bayside Aquarium Supply s factory any product of Bayside s manufacture Bayside will not be liable for any cost of removal installation transportation or any other charges which may arise in warranty claim NOTE This warranty is void if the product is 1 Damaged through abnormal operating conditions accident abuse misuse unauthorized alteration or repair This includes but is not limited to failure to regularly replace carbon and sediment filters 2 Damaged by poor local tap water conditions 3 Damaged due to connection of equipment other than supplied by Bayside Aquarium Supply or modification by the user 4 Damaged by hot water freezing flood fire or acts of God This warranty is valid only in the U S and is non transferable No other warranties are expressed or implied and any other warranties required by law are limited in duration to 90 days This product is not warranted for any specific purpose Bayside Aquarium Supply will not be responsible for consequential damages arising from installation or use of the pr
2. sure that the capillary flow restrictor is installed inside the tubing If the flow restrictor is clogged it will need to be replaced Please contact your local dealer and inform them of the exact model of your Captive Purity System Flow restrictors are different based on the gallons per day rating of your filter system Problem I m not getting the rate capacity out of the unit what could be wrong Solution Output capacity of your RO or RO DI unit can be affected by many variables Temperature of source water low water pressure clogged sediment or carbon cartridge and exhausted membranes are some variables that can affect your water output The production rates are rated at 65PSI and 70 F feed water temperature Booster pumps can be used to boost the line pressure and increase water output If the problem is caused by a filter cartridge or membrane it will need to be replaced Problem Too much product water little waste or resin exhausts quickly Solution This is usually the result of the TFC Membrane not seated properly or a ruptured membrane Open the TFC Housing and firmly push the membrane in place If the membrane is ruptured it will need to be replaced Problem Not enough product water lots of waste Solution Check the TDS high TDS can lower the output Check the Temperature of the feed water low water temperatures like 50 F 10 C will restrict the output to half Check the pressure the ideal water pressure should be 65
3. to be able to unscrew the cap Securely seat the TFC membrane in to the housing there should be about 34 of space from the lip of the housing to the top of the TFC membrane Once the TFC membrane is seated screw on the top and reconnect the tubing Reverse osmosis membranes are packed with an anti bacterial agent to keep them sterile prior to use This agent should be flushed away to avoid human or animal consumption Turn on the water once again and allow the unit to run for 30 minutes to flush out the anti bacterial agent After the system has been allowed to run for 30 minutes the water from the product water line can now be collected for use for a four stage RO DI unit you can now reinstall the DI cartridge and start collecting water for use Trapped air in the DI cartridge is a normal condition and will not affect the operation of the DI cartridge MEMBRANE amp FILTER CARTRIDGE REPLACEMENT SCHEDULE Sediment Cartridge change when visibly dirty 4 8 months Carbon Cartridge change at the same time the sediment filter is changed 4 8 months DI Cartridge For the Deluxe models the color of the DI resin will start to turn orange from the bottom up Replace the cartridge once it has reach to about 1 from the top of the cartridges For the Pro models use your TDS meter to determine when the cartridge should be changed You will notice a dramatic rise in the TDS level once the resin is exhausted Thin Film Composite TF
4. C Membrane should be changed every 2 3 years or when TDS reading is above 30 40 us The use of a flush valve kit is recommended to help extend the life of the TFC membrane All listed service times are approximate Actual service life may be longer or shorter depending on the water source quality and how often the unit is used STORAGE When the unit is not in use it is important to keep the TFC membrane hydrated The TFC membrane must not be allowed to dry out Keep the unit in a cool location and keep all inlet and outlet lines above the unit so the water will remain in the 3 unit If the RO or RO DI system will not be used for more than 4 weeks remove the TFC membrane and store it ina refrigerator inside a Ziploc bag filled with a small amount of purified water Do not allow the RO or RO DI unit to be exposed to freezing conditions or temperatures above 100 F TROUBLESHOOTING Your new Captive Purity RO or RO DI filter should work trouble free out of the box If you have difficulties or questions please contact your local Captive Purity Retailer NOTE The water supply should be turned off and the water pressure should be bled off prior to working on the filter system itself Following are some common problems and their solutions Problem The filter system does not produce any product water Solution A missing clogged or defective flow restrictor is most likely the cause of this problem Check the waste water line to make
5. CAPTIVE PURITY USER S MANUAL Please read thoroughly before installing this product Congratulations You are now a proud owner of the finest reverse osmosis filtration system available Captive Purity has assembled a high quality water purifying system that turns ordinary tap water into sparkling great tasting healthful drinking and aquarium water by combining filtration and absorption With this unit you can be assured that your animals and your family are enjoying the highest quality water possible YOUR REVERSE OSMOSIS RO or REVERSE OSMOSIS DEIONIZATION RO DI SYSTEM SYSTEM SPECIFICATIONS Sediment Pre Filter 1 Micron Sediment Pre Filter Carbon Filter 0 5 Micron Carbon Block Prefilter Pro Model 5 Micron Carbon Block Prefilter Deluxe Model RO Membrane Type Thin Film Composite TFC DI Cartridge Color Change DI Cartridge Deluxe Model Available on RO DI Systems Non Color Change DI Cartridge Pro Model RO or RO DI REQUIREMENTS Operating Pressure 40 100 PSI Ideal Input Water Temp 70 77 F 21 25 C SYSTEM DESCRIPTION The Captive Purity Reverse Osmosis System is available in a Two Stage or Three Stage System The Captive Purity RO DI system is a Four Stage Reverse Osmosis De lonization system Sediment Pre filter First the incoming feed water is passed through a micro tec sediment pre filter This filter is required to remove colloidal and particulate matters that may clog the TFC membrane Carbon Block Pre fil
6. and other accessories fs Intake Line white Connects to your water source Yf yy Product Water Line blue Goes to your reservoir for collection Waste Water Line black Drains to your sink or garden for disposal Figure A Pressure gauge Dual TDS Meter Figure B 1 2 Stage RO System The pressure gauge Figure A standard on RO DI Pro models will allow you to monitor the pressure of the system and make sure that the filter is receiving sufficient water pressure to operate efficiently It will also indicate via a drop in pressure when the sediment and carbon block filters are clogged and need to be replaced The Dual TDS meter standard on 4 stage RO DI Pro models is used to monitor the condition of the TFC membrane and DI cartridge The sensor can also be easily relocated to the intake of the RO unit to monitor the quality of the source water INSTALLATION INSTRUCTIONS NOTE It is recommended to have this unit installed by a licensed plumber to adhere to all local codes It is the responsibility of the purchaser to insure that all fittings are tight and that codes are met WARNING Household water pressure can cause leaks and damage the surrounding building or fixtures if not properly installed User must check all fittings for tightness Bayside Aquarium Supply assumes no responsibility for water damage due to leaks Captive Purity Systems can be mounted to any secure location using hardware screws Keep in mind that t
7. he filter system will gain a substantial amount of weight when it is full of water For this reason it is necessary that the filter system be mounted to a strong backing Mount the filter system level with clearance for all housings and hoses Also keep in mind that there will be space needed to accomplish regular maintenance of the filter system such as pre filter removal If needed additional hardware and plumbing can be found at most hardware or plumbing supply stores Attach the garden hose adapter to your cold water source Never run hot water greater than 100 degree Fahrenheit 38 degree Celsius through the system Place the black waste water line and blue product water line into your drain Do not restrict flow from these lines Do not install the TFC membrane at this point Slowly open the cold water supply valve and allow the first two housings to fill You may use pressure up to 100 psi 5 5 bar Double check the system to ensure that all fittings are tight and leak free before leaving the system unattended for a four stage RO DI unit you will need to first remove the DI cartridge Allow the water to run for 15 minutes to flush the sediment and carbon block filter cartridges Flushing the pre filters will help to maximize the TFC membrane life Next turn off the water supply Remove the TFC membrane from the protective bag and install the membrane into the TFC housing at the top of the RO unit You will need to disconnect the tubing
8. oduct including any flooding which may occur due to malfunction or faulty installation including but not limited to failure of installer to tighten all fittings Gallons per day are not warranted since it is dependent on the users water conditions i e temperature pressure and total dissolved solids
9. ter The second stage of filtration is a carbon block prefilter This filter removes organics and chlorine from the feed water that can damage the membrane for the two stage RO systems the sediment and carbon block filters are combined into one cartridge RO TFC Membrane The third filtration stage of the system is a high rejection thin film composite TFC reverse osmosis membrane It removes over 98 of most inorganic salts heavy metals bacteria and almost all high molecular weight organics in the water The correct waste water to product water ratio is 4 to 1 Deionization Cartridge Available on RO DI Systems The fourth stage moves water through a Deionization Cartridge As water passes through a bed of ion exchange resin these resins attract and absorb ionic contaminants cation resins absorb positively charged ions and anion resins absorb negatively charged ions They are capable of producing 18 meg ohm cm resistivity water Deionization cartridges are designed to reduce silica nitrates and phosphate levels in the low ppb range It is an excellent system for removing dissolved solids and gases SYSTEM DIAGRAM Check the box thoroughly for all parts listed for the type of unit purchased All units come standard with a Garden Hose Fitting If the feed water faucet or sink does not have 4 garden hose threads you will need to purchase a Feed Water Adapter or a Faucet Coupler Check with your retailer for the availability of these

Download Pdf Manuals

image

Related Search

Related Contents

  HP StoreAll 9300/9320 Storage Administrator Guide  Page 1 Page 2 は じ め に このたびはクボタ製品をお買いあげいただき  取扱説明書の表示  Notice boite à relais Lutz RM10  Lennox Hearth MPD35ST-NE User's Manual  Sennheiser SD Pro 2  THE VALUATION TOOL USER GUIDE Monetizing  Vetoquinol-DuPont Biosolve Plus  安全データシート - 林純薬 – 電子材料  

Copyright © All rights reserved.
Failed to retrieve file