1. 50 C Do not use the cameras with voltages different from the ones specified This product should be installed in line with installation rules preferably by a qualified electrician Incorrect installation and use can lead to risk of electric shock or fire Before carrying out the installation read the instructions and take account of the product s specific mounting location Do not open up dismantle alter or modify the device except where specifically required to do so by the instructions All Legrand products must be opened and repaired exclusively by personnel trained and approved by Legrand Any unauthorised opening or repair completely cancels all liabilities and the rights to replacement and guarantees Use only Legrand brand accessories CIO PACKAGE COMPONENT e Product amp Accessories Main Body amp Surface Mount Bracket Default Accessories Main Cable Calblock Screws Tapping M4x16 Tapping M4x25 Machine M3x6 Machine M3x8 I O Cable MAIN PART DESCRIPTION e Product amp Accessories Surface Mount Bracket Mounting Screw Hole Main Connector dr Sensor I O Port Dome Cover Lock up Screw Dome Cover Assembly Stud DIP Switch Dome Cover Dome Cover Do not detach the protection vinyl from the dome cover before finishing all the installation process to protect the dome cover from scratches or dust Dome Cover Lock up Screw Used to lock up the dome cover after assem
2. MPS 129 4 MPL 127 MPS 13 5 MPL Unit mm 16 17 18 19
3. the sensors are divided into Open Collector type and Voltage Output type in general the wiring must be done properly after considering those types Signal Description 3 O IN COM The electric power source to drive input circuit Connect the wire of electric power source to drive the Sensors to this port as shown in the above circuit INT IN2 Connect the outputs of sensors to each port as shown in the above circuit IN3 If you want to use Alarm Input the types of sensors must be selected in OSD menu The sensor types are divided into Normal Open and Normal Close If wrong sensor types are selected alarms should be activated reversely to sensor inputs Normal Open Output Voltage is high state when sensor is activated Normal Close Output Voltage is high state when sensor is not activated e Relay Output Internal AC or DC E I O N OUT 1 d The maximum loads are as follows CHECK POINTS BEFORE OPERATION Before turning on the system check if the wire s and cable s are connected properly Check if the camera ID on the controller is properly selected The camera ID must be identical to that of the target camera The camera ID can be checked by reading the DIP switch of the camera or on OSD If your controller supports multi protocols the protocol must be changed to match to that of the camera Adjust the DIP switch after turning off the camera If yo
4. upside of the ceiling In case of wiring and mounting surface cabling through the ceiling tile only Tapping M4x25 CO Connect the wires and cables to the ports and Align the dome cover stud with the dome cover install the main body Machine M3x8 assembly stud and slightly push the dome cover to the ceiling Turn the dome cover clockwise and screw on the dome cover lock up screw Then remove the protection vinyl from the dome cover Machine M3x6 Important Notice Before starting the installation make sure that the Camera ID and Protocol are set up properly When the pipe hole for wiring and cabling on side of the Surface Mount Bracket is not used make sure that the hole is properly sealed with the supplied Hole Plug WIRING AND CABLING POWER BNC MAIN CABLE MONITOR x MIC SPEAKER ell RS 485 en SENSOR SWITCH O CABLE SENSOR 1 0 IR DO Port Description Main Cable Port Pin Number RJ45 Connector Wire Color Signal BNC Connector o ss Re RS 485 RS 485 Ll 6 Wiel Power OE I O Cable Port Pin Number R25 Weeer Signa i Re ns tite crt e Audio Cable Port Pin Number Connector Wire Color Signal E TE RCA Yellow Audio IN 1 Audio GND Audio OUT 10 e Power Description e Carefully check the voltage and current cap
5. acity of the rated power The rated power is indicated in the back of main unit Input Voltage Range Current Consumption DC 11V 15V 0 8A For the DC input models be careful with the polarity of DC power The system should be permanentally damaged by wrong DC input In case that the length of the power wire is very long there may be voltage drop and the syatem may not work properly Make the length of the power wire as short as possible e RS 485 Communication For PTZ control connect the cable s to your keyboard or DVR To connect multiple cameras to a single controller RS 485 communication should be connected in parallel as shown below If you are connecting a single camera to a controller terminate the camera When connecting more than one camera to a single controller terminate the last camera on the communication line The last camera means the camera farthest in cable length from the controller Note that the total length of the communication cable between a controller and the camera s on the same communication line must be less than 1 2Km CONTROLLER DVR e Video Use BNC coaxial cable only 11 Alarm Input Internal 5V 12V ul y NES IN 1 Sensor 1 gt Tp INS y re Before connecting sensors check driving voltages and output signal types of the sensors Since output signal types of
6. bling the dome cover with the main body Dome Cover Assembly Stud Used to line up the stud on the main body and the stud on the dome cover when assembling the dome cover with the main body e DIP Switch Used to set up camera IDs and protocols e Surface Mount Bracket amp Mounting Screw Hole Used for surface mount type wall mount type and ceiling mount type They are not used for in ceiling mount type Main Connector Used for the power wire the video cable and the RS 485 communication cable connection Sensor I O Port Used for the sensor in out connection DIP SWITCH SETUP Before installing the camera set up the DIP switch to configure the camera ID and the communication protocol e Product amp Accessories TA fe gt SN LO N NG e Camera ID Setup ON ON BinaryValue_ 1 2 4 8 16 32 64 128 ex ID 5 on off on off off off off off ex ID 10 off on off on off off off off The camera ID range is 1 255 Camera ID must not be 0 e The factory default of the camera ID is 1 e Match the camera ID with the Cam ID setting of your DVR or Controller to control the camera e If you are connecting a single camera to a controller terminate the camera When connecting more than one camera to a single controller terminate the last camera on the communicatio
7. ch preset can have its own parameter values independently from the other presets For an example refer to the below table resin mine vce Rg wet remato Presett CaseA Cases ENTRANCE eran ceo casos map Seat casev case corno PETT SAA A Reserved for Preset 128 Casek Caseo TERRACE MAX 8 sets of Swing are programmable This function is that the camera moves repetitively between two preset positions at programmed speeds e MAX 4 Patterns are programmable This function is that the camera memorizes the path mostly curve path by the joystick of the controller and revives the trajectory operated by the joystick as closely as possible MAX 8 sets of Group are programmable This function is that the camera memorizes the combination of Presets Pattern and or Swings sequently and runs Presets Pattern and or Swings repetitively A Group can be combined upto 20 functions with any of Preset Pattern Swing 4 Privacy Masks are programmable not to intrude on any other s privacy PTZ Pan Tilt Zoom Control e With the RS 485 communication connection MAX 255 units of cameras can be connected to a single controller e Pelco D or Pelco P protocols can be selected as a control protocol in the current firmware version OSD On Screen Display Menu e OSD menu is provided to display the status of camera and to configure the functions interactively e The info
8. cted to a controller Due to similar reasons with the case 1 the terminal resister of the controller and the last camera must be set to ON state The last camera means the camera farthest in cable length from the controller Do not turn on the terminal resistor of all the cameras on the same communication cable Controller Terminal Resistor Terminal Resistor Terminal Resistor OFF OFF ON The complete informations are in the manual on the CDrom IN CEILING MOUNT INSTALLATION Connect the wiring and cabling and attach the Remove the ceiling tile from the ceiling and cut camera to the ceiling tile Tapping M4x16 a hole whose diameter is 110mm on the ceiling tile to pass the wires and cables through to the upside of ceiling 4 Turn the dome cover clockwise and screw on the dome cover lock up screw Then remove the protection vinyl from the dome cover Machine M3x6 Align the dome cover stud with the dome cover assembly stud and slightly push the dome cover to the ceiling tile Important Notice Before starting the installation make sure that the Camera ID and Protocol are set up properly INSTALLATION WITH SURFACE MOUNT BRACKET Remove the ceiling tile from the ceiling and cut a Prepare the surface mount bracket hole whose diameter is 30 40mm on the ceiling Pull the wires and cables for the system as tile to pass the wires and cables through to the below Attach the surface mount bracket to the
9. e Cam ra couleur d me motoris e jour nuit 3 8 38 mm 10X 3 8 38 mm 10X motorized day night dome colour camera e Camara de c pula en color motorizada dia noche 3 8 38 mm 10X e C mara a cores c pula motorizada diurna nocturna 3 8 38 mm 10X e kamera kolorowa ze sklepieniem z nap dem dzie noc 3 8 38 mm 10X a H legrand 430 521 User manual LE03664AA FEATURES Powerful Zoom Camera amp Setup Options 10x Optical Zoom 10x Digital Zoom 100x Max zoom magnification High light compensation Privacy Mask Day amp Night Focus Mode Auto Focus Manual Focus Semi Auto Focus OSD Menu Image Sensor Sony interline Transfer CCD Powerful Pan Tilt Functions e MAX 360 sec High Speed Pan Tilt Motion e With the Vector Drive Technology Pan Tilt motions are accomplished along the shortest path As a result the time to target view is remarkably short and the video on the monitor is very natural in monitoring e With the Micro Stepping Control Technology the video looks very natural at high zoom magnification during a jog operation on a controller since the camera can be controlled by 0 05 sec Hence it is very easy to make the camera focus on desired target views at high zoom magnification Additionally it is easy to make the camera focus on desired positions with zoom proportional pan tilt movement Preset Pattern Swing Group Privacy Mask and More e MAX 127 Presets are programmable and ea
10. n line The last camera means the camera farthest in cable length from the controller e Note that the total length of the communication cable between a controller and the camera s on the same communication line must be less than 1 2Km e Communication Protocol Setup Select an appropriate Protocol with the DIP switch combination Protocol em di 3 OFF OFF PELCO D 2400 bps fee fai e Match the camera protocol with the camera protocol in the setting of your DVR or controller to control the camera e Adjust the DIP switch after turning off the camera If you changed the camera protocol by changing the DIP S W the change will be effective after you reboot the camera The factory default protocol is Pelco D 2400 bps e Terminal Resistor Setup e The terminal resistor is used for the following cases e Case 1 In case that the control cable length between a camera and a controller is relatively very long 1 1 Connection If the communication cable length is very long the electrical signal will bound in the terminal point This reflected signal causes distortion of original signal Accordingly the camera can be out of control In this case the terminal resistor of both sides i e the camera and the controller must be set to ON state e Case 2 In case that multiple cameras are conne
11. rmation such as Camera ID Pan Tilt Angle Direction Alarm Input and Preset is displayed on screen Alarm In Out Function 3 alarm sensor inputs and 1 alarm sensor outputs Alarm sensor input is decoupled with photo couplers to avoid external electric noise and shock perfectly e Both of N O Normal Open sensors and N C Normal Close sensors can be used and the signal range of the sensor input is from DC 5 0V to 12 0V for various applications The camera can be set to move to a Preset position or to run functions such as Pattern Swing and Group when there are external sensor activations Also Post Alarm function is possible which is supposed to activate after user defined time period and sequentially in succession to the action by external sensor activations Reserved Presets Hot Keys e Most camera setup options can be set up easily and directly with the reserved presets Hot Keys without entering into OSD menu For more information refer to Reserved Presets Hot Keys ZA warning A Safety instructions The installation and calibration of this camera must be carried out by highly skilled personnel Do not open the camera there may be a risk of electric shock Low voltage cameras must be powered by a power supply unit with stabilized voltage This range of cameras has been created for CCTV applications and nat for other uses Use these cameras only for the following temperature conditions from 10
12. u changed the camera protocol by changing the DIP S W the change will be effective after you reboot the camera Since the operation method can be different by controllers refer to your controller manual if the camera can not be controlled properly The operation of this manual is based on the standard Pelco Controller 13 SPECIFICATIONS CAMERA PART Video Signal Format Image Sensor 1 4 Interline Transfer CCD Total Pixels 795 H x596 V 470K Effective Pixels 752 H x582 V 440K Horizontal Resolution Video Signal to Noise Zoom Forcal Length F1 8 f 3 8 38mm Angle of View Zoom Speed Minimum Illuminance Day amp Night Focus ris Shutter Speed AGC White Balance BLC Flickerless SSNR Privacy Zone MECHANISM PART ESB 360 Endless Movement Range S Dom se 360 sec Speed 0 05 360 sec Proportional to Zoom 1 180 sec Preset 127 Presets Label Independent Camera Parameter Setting Pattern 4 Patterns 1200 Commands Approx 5 Minute Pattern 8 Groups MAX 20 Actions with The Combination of Preset Pattern and Swing Fan Fan Always ON Operation Start from Internal Temperature 10 C Operation Temperature 0 C 40 C 14 MECHANICAL Surface Mount Ceiling Mount Dome Polycarbonate Material Polycarbonate ABS Polycarbonate 107 5 mm 4 2 Note Check the voltage and current capacity of rated power carefully 15 DIMENSION e Main Body e Surface Mount Type 132 4

Download Pdf Manuals

image

Related Search

Related Contents

HX-DC3 (8.70 MB/PDF)  Vos remboursements Mode d`emploi - PDF 131 Ko  Valueline VLAP24200B10  Intel MPRTM4808 User's Manual  DE EN FR NL PT ES IT ODYS MP3-Player X30+ ODYS MP3 player  Sony CDX-F5005X Operating Instructions  Designers Choice Collection AC18842-SN Instructions / Assembly    M anual _ I nstalacion _ R apida _ C ell F ax P lus _ 2  ST 300, ballons de stockage  