Home

The Professional`s Choice

image

Contents

1. tank temperature Ow mane m READY initial heat up minutes then turn an HEATING Faulty element l mA Afa oc Guanen oll ary satety LT switch tripped persists us NOT in Ready mode 2 n REA DY due to excessive Reduce aA HEATING L setting lt A Ze ee Temperature ue sensor i TIT AN AN disconnected Call service if fault oa _ or wires cut persists
2. with average or medium water hardness Hard and Soft Water The effectiveness of the filter will be reduced in hard water areas and should be replaced more frequently or extended in soft water areas where scale is less of a problem If in doubt as to the hardness of water supplied in your area consult your local water authority or Instanta Technical Support The filter monitor on the boiler can be changed from the default medium setting to hard or soft setting as follows Replace the filter cartridge as steps 1 to 9 AQ35 Filter Replacement above Then Turn machine off Press amp hold on off button for approximately 12 seconds until red screen shows PR in top right corner then release button Temperature setting is displayed Press amp hold button long push for approximately 5 seconds until screen changes to show medium default filter setting Press button short push to scroll between the different filter settings SOFT MEDIUM HARD EMPTY FILTER SYMBOL No Filter monitor With the required filter setting selected Press amp hold button long push for 4 seconds to save Press amp hold button long push for approximately 6 seconds until display goes blank Turn machine back on again TO RE SET amp CONFIRM NEW SETTINGS Press amp hold button screen will go blank but continue to hold until READY message is displayed on a red s
3. Delivery Checklist Before starting installation check that you have the following parts e Catering Water Boiler e Drip tray e Drip tray fitting kit e White water inlet hose 3 4 BSP connection e User instructions Technical Specification Model 1501F 3001F Width mm 252 308 Depth mm 362 362 Height mm 610 618 Power Rating KW 3 0 3 0 Weight Empty KG 13 5 15 5 Weight Full KG 28 36 Water Inlet Pressure Bar 2to7 2to7 Installation The boiler must be installed on a horizontal work surface with sufficient strength to support its weight Locate in an area where there is adequate space to use the boiler safely e g free from risk of congestion and tripping hazards Connection to Mains Water Supply Connect the WRAS approved water filling hose 3 4 BSP to the inlet connection point on the back of the boiler and the other end to the mains water supply via an accessible isolating tap with a 34 BSP thread IMPORTANT If micro bore pipe is used instead of the inlet hose supplied the size must be minimum OD 3 8 10mm The water supply must have a pressure not exceeding 7bar 96psi and no lower than 2bar 20psi NOTE If your water pressure exceeds Tbar fit a suitable pressure reduction valve We regret that Instanta cannot be held responsible for any machine malfunctions if the water pressure exceeds that stated If in doubt consult your water supply compa
4. SF Range Models 1501F amp 3001F Auto Fill Catering Water Boiler With Integrated Multi Filter Installation And User Instructions INSTANTA LIMITED Canning Road Southport Merseyside PR9 7SN Tel 01704 501114 Fax 01704 501115 IB31 ISS 01 CONTENTS CONTENTS amp INTRODUCTION SAFETY INFORMATION ENVIRONMENTAL INFORMATION amp DELIVERY CHECK LIST TECHNICAL SPECIFICATION INSTALLATION OPERATION DAILY USE FILTER amp FILTER REPLACEMENT ADJUSTING FILTER MONITOR optional CLEANING MAINTENANCE SPARES amp SERVICE INFORMATION SERVICE TECHNICAL SUPPORT GUARANTEE SERVICE WARNINGS amp FAULT DIAGNOSTICS CoO N N O DO A A HF WB WB WB N N Introduction e Local amp national Building Regulations Dear Customer e BS Codes of practice Thank you for purchasing this Instanta product e Water Supply Regulations Your new water boiler is designed to give you All personnel should be provided with sufficient years of trouble free service provided that training in the safe use of this appliance A the instructions contained in this manual are warning notice displayed next to the machine is followed often helpful in notifying users that the appliance contains and dispenses near boiling water All new series Instanta products are energy efficient simple to operate and easy to service Find out more about Instanta products at www instanta com Safety Information Please read the following carefully bef
5. boiler again e Replace evaporation plates tank lid and outer lid Draw off tap The tap spring and washer components are subject to wear amp tear It is advisable to keep a spare tapspring and washer in case of emergencies Accessories amp Spares Tel 01704 502905 TP1001 L TP1007 N Replacement Tap Washer Replacement Tap Spring AQ35 ROFK1 Replacement Filter Cartridge Rear overflow Kit connection to perm waste A full range of spares and accessories are available from our spares department Service Technical Support Tel 01704 502911 To ensure your service enquiry is handled as efficiently as possible please have the following information available e Brief description of problem e Product Type model e Serial Number label on right hand side of machine This is essential Guarantee Your boiler is guaranteed for twelve months from date of installation Our guarantee includes on site labour and parts for problems caused by fault of manufacture and component failure with the following exclusions Problems caused by hard water and lime scale We regret that we cannot be held responsible for problems caused by hard water e Dripping Taps These components are subject to wear and tear but in the event of a tap failing within twelve months of installation we will be pleased to replace the tap assembly by post Fitting is very simple and requires no tools An engineer call out is not nece
6. continue to operate with the CHANGE FILTER screen but scale may build up more rapidly and the water taste may be affected Replace the filter as follows 1 Switch boiler off and draw water down to tap level 2 Grip cartridge and rotate a quarter turn to the left and pull forward CAUTION A small amount of water will drain from the head 3 Align a flat screw driver or similar with the tab 6 Remove protective cap from the top of the on the filter and gently push new cartridge and ensure the two rubber seals are in place 7 Insert new cartridge and turn until it locates 4 With one tab loosened pull the filter cap off Install with a quarter turn to the right until the old cartridge cartridge comes to a complete stop Inlet water will automatically turn on 5 Align the shape on the inside of the filter cap highlighted above with the shape on the end 8 Switch boiler back on and allow to fill of the new filter and push the two together 15 minutes until it clicks firmly in place 9 Drain off approximately 10 litres of water 10 TO RESET FILTER MONITOR Press and hold On Off button screen will go blank but continue to hold until READY message is displayed on a red screen The boiler is now ready for use Adjusting Filter Monitor Optional The filter monitor is factory set to medium default which is suitable for most parts of the UK
7. creen See Step 10 above Cleaning Clean the external surfaces of the boiler regularly to maintain good hygiene Empty the front drip tray regularly Wipe external surfaces of the boiler with a damp cloth Do not use abrasive materials on the outer surfaces Wipe the draw off tap each day to keep clean and also prevent lime scale deposits from building up around the tap outlet Maintenance amp Service Information Filter Twist to the left and remove See AQ35 Filter Replacement section above Descaling The boiler should be periodically checked for scale build up see below In hard water areas the boiler should be descaled on a regular basis to maintain efficient operation minimise energy consumption and also retain the water quality The frequency depends on the hardness of the local mains water supply and the regular replacement of the AQ35 filter cartridge To de scale e Disconnect machine from power supply e Empty the machine through the draw off tap and allow to cool e Lift off the outer lid e Remove tank lid four fixing screws e Lift out the evaporation plates inside of tank Remember order of removal e Remove as much scale as possible by hand Any scale which is difficult to remove can be dissolved by using a de scaling solution e Wipe clean the level sensing probes e Flush with copious amounts of cold water to ensure all traces of de scaler are removed before using the
8. ill cycle until the tank is at full capacity During the heat fill cycle small amounts of water are added to ensure the water at the tap is always at the correct temperature IMPORTANT NOTE In normal daily use the boiler may be used as soon as the READY message is displayed but on first install wait at least 15 minutes before starting to use e Drain off approximately 10 litres of water to flush the new filter cartridge through e The boiler is now ready for use Regular Daily Use Switch boiler on and wait for the screen to turn white and show READY message The water will then be at the correct temperature Dispense water via the lever tap CAUTION Boiler dispenses near boiling water AQ35 Multi Filter Instanta s new built in filtration system ensures that water is always to the highest standard whilst delivering lower maintenance costs and improved energy efficiency Quick and easy to change the new filter reduces sediment chlorine taste amp odour and lime scale via a slow release scale inhibitor providing better water and therefore better quality drinks Filter Replacement A series of bars on the FILTER display shows the estimated remaining life in the current filter cartridge When the filter has just 200 Litres remaining the filter icon will begin to flash as a reminder When the filter needs replacing the screen will show the message CHANGE FILTER The boiler will
9. ny Electrical Connection The boiler must be Earthed Your machine is supplied with a standard 13amp bonded plug with a 13amp fuse Overflow The drip tray has a limited capacity and is designed to handle small spillages and drips Wherever possible we strongly recommend that it is connected to a permanent waste outlet using the fitting kit provided If preferred and as an alternative the overflow can be connected from the back of the machine using an optional rear overflow kit Pt No ROFK1 available from Instanta Spares Department 01704 502905 IMPORTANT Whichever overflow connection is chosen the diameter of the pipe used must be no less than 15mm Whilst every reasonable precaution is taken to prevent an overflow Instanta cannot be held responsible for any damage caused as a result of incorrect installation or blockage of the overflow or failure to direct the overflow to a safe outlet Operation First use once water and electrical connections have been made e Switch boiler on The screen will light up red and will run through an initial self diagnostic check before starting to fill with water screen reads NOT READY FILLING e Once primed with water the boiler will begin to heat Screen reads NOT READY HEATING e When the correct temperature has been reached the display will change from Red to White and will simply read READY e The boiler will then continue in a heat f
10. ore gt starting work on this equipment A competent person should install this appliance in accordance with the installation instructions a for this appliance and all relevant local and national standards including the following e Health amp Safety at Work Act e IEE Regulations Inform users that certain surfaces will become hot especially the draw off tap Care should be taken to avoid potential injury from burns and scalding whilst operating this appliance In line with Health and Safety requirements we recommend a risk assessment be carried out after the boiler has been installed Always disconnect the unit from the power supply before servicing The unit must be earthed Keep these instructions in a safe place near the unit for future reference Environmental Information On Disposal For Users Of Waste Electrical amp Electronic Equipment The crossed out wheelie bin symbol on this product means that discarded electrical and electronic products should not be mixed with general waste Disposing of the product correctly will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling For proper treatment recovery and recycling of end of life products please contact your dealer or supplier for further information or local authority for details of your nearest designated collection point
11. ssary e Accidental damage misuse or use not in accordance with these instructions and damage caused by incorrect installation e The manufacturer disclaims any liability for incidental or consequential damages Service Warnings And Fault Diagnosis Your boiler is fitted with an intelligent fault diagnosing system and is able to detect various fault conditions Some of these are less serious and the machine will continue to operate as normal while others are more serious and will disable the unit Before calling for service switch the machine off at the mains supply Draw off a small amount of water and then switch back on after 10 minutes If the fault does not clear call technical support for advice SCREEN MESSAGE POSSIBLE CAUSES ACTION WHITE SCREEN dS AIIN WHITE SCREEN READY CLEAN PROBES WHITE SCREEN ATTN CELLED Water turned off READY inlet hose and stop cock CHECK WATER kinked or bent ii Low incoming water pressure e Filter cartridge is e Replacement filter READY exhausted and cartridge available should be from Instanta CHANGE replaced as soon Spares FILTER ni nt wattle as convenile Part no AQ35 Check water supply Check incoming water is at minimum of 2 bar Low water level De scale probe scaled up Over boil safety NOT switch tripped on Isolate machine and wait for 10 back on again Call service if fault Over boiled when De scale limescale in

Download Pdf Manuals