Home
Druck Air Data Test Systems
Contents
1. seem 17 Loading a test program oe Ted abi 17 Operating a test program nn essen 17 FAR 43 test program sense nen eisen 18 Down loading a test program to the ADTS uu422uesrsnnnn ernennen nenne ernennen 18 Up loading result files 1 o itte inerte roti Pe nndis 18 TPM files and Protectio Mannisen Rennen 19 APPENDIX FAR 43 ALTIMETER TEST PROGRAM uueessnsneesnnnersnnennennnnennnnner nennen A 1 Summary A 1 Description A 1 Test 1 Case Leak A 1 Test 2 Scale Error Hysteresis and After Effect neen A 1 Seas d A 1 Hysteresis u mente einen A 1 After Effect ein Sh idee ee erin Mae A 2 Test S FriCllOni 4 eere FREE FEIRCREEERREEFEHREPERTESERETERUERITENELTERTEERTFELERSTEEETERE A 3 Test 4 Barometric Scale Error essem A 4 K250 Issue No 2 Preliminary ABBREVIATIONS The following abbreviations are used in this publication NOTE Abbreviations are the same in the singular and plural ADTS Air Data Test System ALT altitude ARINC Air Radio Incorporated CAS Calibrated airspeed CD ROM compact disc read only memory COL column COM communication port contd continued CR carriage return C degrees Celsius CGA colour graphics adaptor DOS disk operating system EPR engine pressure ratio FAR Federal Aviation Regulation FS full scale ft feet ft min feet minute IBM International Business Machines inHg Inche
2. K250 Issue No 2 The command line editor allows control of the ADTS using TPM language A single command can be typed and executed as if typing a test program Every time an action associated to a TPM command is executed e g to set a parameter to a certain pressure or to select a unit the command will be displayed and placed in the command line editor If the record box has been ticked the command line will be copied across into the program editor window This allows a test program to be written automatically when carrying out an action in manual mode Program mode The program mode allows the running of a test program or part of it by selecting the tests to execute Click on the program tab and the display shows the test program editor H TPM Ele View Options Help Manual Once a test program has been selected in the test program editor it can be started by selecting Run all program Single C Alt 200 Double Leak Measure Tripe C Encoder C CAS 0 0 Kts Er Leak Measure PtOnly C If this program is made of several tests each can be selected and run separately by selecting Run Specific Tests s gt Runallprogram F4 ti Run specific tests F3 lt Stoptest Esc At any time a test program can be interrupted by selecting Stop Test Test program editor window To display the Test Program Editor from the main window click on Program or select from the View menu T
3. smaller unit or down to all removable parts Examine To perform a critical visual observation or check for specific conditions to test the condition of Fit Correctly attach one item to another Inspect Review the work carried out by Specialists to ensure it has been performed satisfactorily Install To perform operations necessary to properly fit an equipment unit into the next larger assembly or system Maintain To hold or keep in any particular state or condition especially in a state of efficiency or validity Make sure To confirm that a proper condition exists to find out with certainty Operate Ensure that an item or system functions correctly as far as possible without the use of test equipment or reference to measurement v K250 Issue No 2 Preliminary Readjust Reconnect Refit Remove Repair Replace Reset Service Test To adjust again to move back to a specified condition to bring back to an in tolerance condition To rejoin or refasten that which has been separated Fit an item which has previously been removed To perform operations necessary to take an equipment unit out of the next larger assembly or system To take off or eliminate To take or move away To restore damaged worn out or malfunctioning equipment to a serviceable usable or operable condition Remove an item and fit a new or a serviced item To put back into a desired position adjustment or condit
4. the Druck ADTS 100 101 300 301 series as well as ADTS 405 and 405F Printers Existing printers in use with a Druck ADTS can be utilized as the output device Alternatively any serial or parallel Centronics printer compatible with a PC can be used e The quality of the print out depends on the printer used Printers supporting IBM graphics use solid lines to draw result tables other printers will draw the tables using dotted lines Note If printing is to be carried out using a printer connected to the ADTS then the printer must have a parallel Centronics interface 3 K250 Issue No 2 Intentionally left blank K250 Issue No 2 4 Druck Test Program Manager Version 4 0 User Manual TPM SOFTWARE INSTALLATION Installing the Software The software is supplied on a standard CD with AutoRun 1 Insert the CD into the CD ROM drive on the computer Note Ifthe computer is not set up to open a CD automatically AutoRun use a browser to show the contents ofthe CD and double click the file MASTER EXE 2 A menu screen opens Druck Test Program Manager Read Manuals Install Drivers Install Software Quit 3 Select the option Install Drivers and follow the on screen instructions This installs the necessary serial communications support 4 Select the option Install Software and follow the on screen instructions This installs the TPM software program Install Software copies
5. 43 Appendix E 1982 Section a 1 iv 1 2 3 Altimeter vibrator circuit set to off The altitude increases to each set point in Table 2 at a rate of 6000 ft min reducing to less than 750 ft min when nearing the set point At each set point a user reading recorded followed by altimeter vibrator circuit set to on and another user reading recorded The difference between the two readings compared with the tolerance shown in Table 2 At the end of the test the altitude decreases to zero ground Table 2 Friction Test A 3 K250 Issue No 2 Druck Test Program Manager Version 4 0 User Manual Test 4 Barometric Scale Error Table 3 FAR 43 Appendix E 1982 Section a 1 i 1 The altitude controlled at zero feet and the user instructed to set the altimeter s barometric scale to each of the values in Table 3 2 A user reading will be taken for each setting and checked against the indicated altitude values in the Table 3 with a tolerance of 25 feet 3 The altitude set to ground go to ground at the end of the test Table 3 Barometric Scale Error mw tem K250 Issue No 2 A 4 Customer service Druck has joined other GE high technology sensing businesses under a new name GE Sensing Visit our web site www gesensing com
6. GE Sensing Druck Air Data Test Systems Test Program Manager Version 4 User manual K250 Copyright 2006 General Electric Company All rights reserved Trademarks All product names are trademarks of their respective companies Druck Test Program Manager Version 4 0 User Manual Introduction o This technical manual provides details of installation preparation and operation for the Druck Test Program Manager Scope o This technical manual contains a brief description installation and procedures for the user of this equipment compatible with the requirements of first line operation Language and Communications o The language and communication procedures are common to all types of Druck ADTS 405 and are contained in the TPM Language Reference Manual Publication number K230 Safety o The manufacturer has designed this equipment to be safe when operated using the procedures detailed in this manual Do not use this equipment for any other purpose than that stated o This publication contains operating and safety instructions that must be followed to ensure safe operation and to maintain the equipment in a safe condition The safety instructions are either warnings or cautions issued to protect the user and the equipment from injury or damage o Use qualified personnel and good engineering practice for all procedures in this publication Pressure Do not apply pressure greater the maximum safe working pre
7. XE file the default installation puts this file in Program Files Druck TPM directory Choose Run from the Microsoft Windows Task bar Start menu and then Open Type the path of TPM EXE Setting up When used for the first time the TPM displays the Setup window see page 11 9 K250 Issue No 2 A brief description of the TPM environment The Test Program Manager comprises five different windows Main window Where the ADTS can be controlled manually and test programs can be run or down loaded 0 Program Editor Where the test programs can be created and edited Result files window Where the results files are created displayed and compiled as the test program runs Simulator window Where the simulator of ADTS is turned on or off and its speed set up see page 15 Warning window Where this display appears only after a test program is down loaded into the ADTS and when some of the commands are misused see page 16 Main window Test program Results file editor editor DELE Program Edit Help TITLE My First Program TEST 1 Test 1 AIM ALT 500 Go EJTPM prugrami tpm Eile View Options Help p i Singe C Alt Double Leak Measure Tie C Encoder C CAS 0 0 Kts UM Leak Measure PtOny C ALT sPEED mach rem Roc RATETIMER HOLD rare CONTROL GROUND fex Command line WAIT 2 PRINT Test ended Result Files E
8. al tab 200 T box Leak Measure T pe C CAS 0 0 Kts IEE Arinc428 C Pt Only C Display ALT SPEED MACH EPR ROC RATE TIMER HOLD RATE eak Measure Nudge CONTROL GROUND fects knots y v keys Key pad sSxb o LM a een m 7 Command line Unit selection box Record Command line and record box Status bar selection box Using the mouse to point and click the selections are the same as key presses on the ADTS front panel Similarly the display can be configured in the display type box to single dual or triple When an option of the ADTS is connected Altimeter encoder or an ARINC 429 interface select the option in the display type box to change the display to show the option data The key pad selections are the same as the ADTS front panel with the following exceptions Units can be selected from the unit selection box The list of available units shown in the selection box depends on the ADTS software version and selections made in setup see the ADTS User Manual 0 There may be units available on the ADTS that are not available on TPM even with the correct ADTS software version selected This is because some units cannot be controlled remotely by TPM Some keys may be disabled if they are not usable in the selected units i e with pressure measurement units such as mbar or inHg the MACH key is disabled similarly with feet and knots selected the EPR key is disabled 13
9. ccompanying TPM Language Reference Manual should be used when creating or editing test programs The programs are written in the test program language for the air data test system which is both man and machine readable It uses English words such as PRINT and AIM but has closely defined syntax 1 K250 Issue No 2 Introduction The test program language can create the following types of tests to efficiently minimize test times Leak tests Airspeed or altitude switch tests Barometric scale error tests Ground proximity warning tests Engine pressure ratio tests Multiple print outs of pilot copilot and standby instruments Airspeed tests during altitude tests with separate print outs without affecting altitude print out Scale error tests Hysteresis tests Friction tests Other Pitot Static tests generally found in aircraft test procedures If required we can provide assistance in writing the test programs K250 Issue No 2 2 Druck Test Program Manager Version 4 0 User Manual INSTALLATION Hardware Requirements PC e The TPM operates on any IBM PC XT AT or compatible computer with a VGA display e The TPM is particularly suitable for note book or lap top PC with an LCD display It is recommended that the PC has a hard disk drive with 500K byte of free space e The PC must be operating Windows 95 98 or NT Cables The TPM comes complete with all necessary cables enabling connection to
10. dow The simulator acts as the ADTS the test program can be run without connecting the PC to an ADTS The displays user input and printed results will be as normal This facility can be used to verify a new test program without connecting and operating aircraft systems or instruments It can also be used to gain familiarity with test programs and the TPM The simulator window appears when a TPM mode is selected Manual or Program or by clicking the View menu in the main window The simulator or the ADTS can be selected by pointing and clicking the appropriate box Die The simulator speed can be changed by moving the cursor on the speed bar and can increase the speed up to a factor of T ADTS 50 This affects the simulated rates of change and can be used to speed up the Speed 1 Ll gt simulated program execution Selecting the ADTS box disables the speed bar The simulator cannot be selected on or off when a test program is operating Iv Simulator 15 K250 Issue No 2 Warning window Before down loading a test program to the ADTS the program commands are checked against the ADTS software version A warning message will be display in the following cases 0 The TPM command might not be a valid command for this ADTS software version This command has been updated and accepts some new parameters The TPM cannot detect an invalid parameter in this software version check in the TPM Language Manual if the pa
11. es to be protected from change Both the Test Program editor and the Result File editor have the option to be protected in the Password set up A protected TPM file in text file format cannot be edited or saved There are two file formats for the TPM files o Encrypted unreadable without TPM o Text file format can be read and edited with any text editor The protection prevents the changing of the contents of a TPM file The editor becomes read only with part of the EDIT menu window disabled and grey The Record facility from the Manual mode is also disabled The following tables show the actions allowed and disallowed with both editors No password set up or Yes Ye Y password entered es es es Load encrypted Load not encrypted Record M No password set up or Yes Y password entered Yes es es where Save as encrypted Saved encrypted test program files have the extension TPM saved encrypted result files have the extension TR Save as text The test program saves a text file with the extension ATP and saves a result file with the extension LST File Edit A file can be edited by direct access using the mouse or cursor with the normal edit menu functions Copy Cut and Paste Load Encrypted The file to be encrypted is displayed in a decrypted form in the editor 19 K250 Issue No 2 OPERATION Load not encrypted The text file is displayed in the edit
12. est program When the header screen appears input the required data for each field and press tab to move to the next field After completing the header information press the OK button the first test starts Down loading a test program to the ADTS When loaded in the TPM a test program can be down loaded to the ADTS by clicking in the main window on the menu Files Download Test Program The warning window may display an error message see page 16 for details The display may show instructions to be carried out before continuing the down load If test program file of the same name has already been down loaded a prompt asks if it should be replaced If communications between the ADTS and TPM are not correct refer to the note on page 17 Controlling the ADTS in manual mode Up loading result files Option available with ADTS 405 with software version DK 127 V4 40 onwards The ADTS 405 can be set up to save the result data into a file instead of printing while testing Result files can be up loaded by clicking on the menu Files Upload Result File A list of result files contained in the ADTS is then displayed in the main window A result file can be up loaded and displayed in the Result editor window To save the result file on the PC hard disk rename before saving K250 Issue No 2 18 Druck Test Program Manager Version 4 0 User Manual TPM files and Protection The Test Program Manager allows the TPM fil
13. he Test Program Editor can be used to create a new test program or load edit or print an existing test program During the test program execution the command line executed is coloured blue If errors occur the command line changes colour to red A protected Test Program Editor see TPM files and protection page 19 cannot be edited and some of the menu items are disabled Clicking the mouse right button accesses the edit functions in a pop up menu K250 Issue No 2 14 Druck Test Program Manager Version 4 0 User Manual Result file editor window To display the Result File Editor from the main window click on View menu or operate a program EJ Result Files MEF The Result File Editor allows editing or Eile Edit Window Help printing of several existing result files a DEHRA iol x AL ESTE ALTITUDE 800 feet Each time a result file is created it is displayed in a new window within the Result File Editor The highlighted result window has a white background On execution of a test program the TPM automatically makes a result file and gets the file name from the test program name 4 If another result file has the same name a prompt asks to change the name or the previous result file will be over written A protected result file editor like the test program editor has some of the menus disabled and no result file can be edited see TPM files and protection Simulator win
14. he tolerance column 3 Hysteresis FAR 43 Appendix E 1982 Section a 1 ii 1m Altitude decreases to the first hysteresis set point column 4 2 The rate of change between set point values set at 6000 ft min reducing to less than 3000 ft min when nearing set point 3 After 5 minutes at this set point user reading recorded and compared with the recorded reading for increasing altitude within the tolerance column 5 4 Altitude decreases to the second hysteresis point column 4 and after a 1 minute wait at this set point user reading recorded and compared with the recorded reading for increasing altitude within the tolerance column 5 A 1 K250 Issue No 2 Druck Test Program Manager Version 4 0 User Manual Altitude ar tolerance detis tolerance x 1 minus 2 2 minus 4 feet increasing decreasing feet altitude feet altitude 1 2 3 4 5 1000 N o o ie o x after effect o A jolojoj mim nm OlOG ojojojoljo where N x hysteresis N x hysteresis x manually recorded and entered value Table 1 Scale Error Hysteresis and After Effect After Effect FAR 43 Appendix E 1982 Section a 1 iii 1 Altitude decreases to zero at 6000 ft min 2 After a 1 minute wait user reading recorded and compared with the recorded reading for increasing altitude within the tolerance column 5 K250 Issue No 2 A 2 APPENDIX Test 3 Friction Table 2 FAR
15. ick on the Program menu Files Load to load the selected program The Test Program editor displays the selected program commands and the main window title bar changes to display the selected program file name Operating a test program After loading the selected test program and if the TPM is not in program mode point and click on the main window Program Point and click on the Run all program Once a test program starts manual mode cannot be selected until completion of the test If there are several tests in the test program a selection of abort or resume can be made between each test Manual mode can be selected between each test by pointing and clicking on Manual On completion of all testing make sure that all aircraft systems are at atmospheric pressure using manual mode or by using the TPM command GROUND at the end of the test program When all systems are at atmospheric pressure disconnect the ADTS from the aircraft or instruments under test 17 K250 Issue No 2 OPERATION FAR 43 test program We supply the TPM with a complete FAR 43 test program This FAR 43 test program produces standard testing procedures for different aircraft types Note A back up copy should be made before editing See the Language Reference Manual for further details Details ofthe FAR 43 test are included in Appendix A General To use this test program proceed as follows Input header information at the start of a t
16. ion To perform such operations as cleaning lubricating and replenishing to prepare for use Ascertain by using the appropriate test equipment that a component or system functions correctly K250 Issue No 2 vi Druck Test Program Manager Version 4 0 User Manual INTRODUCTION The Druck Test Program Manager software package operates on any IBM PC compatible computer with Windows 95 98 or NT The TPM requires an RS232 serial data link connected between the PC and the Druck ADTS hand held terminal connector The TPM operates under user control using predetermined test programs or enables the user to enter individual air data test system commands This facility processes test procedures such as recording values and readings from instruments under test Instrument readings and other test results can be entered in the PC by the user A printed copy of the test results can be produced at a later time from the test results files stored in the PC The TPM also has a simulator mode to test debug and gain familiarity with test programs The TPM allows the user to e Select a test program Use all or part of a test program e Temporarily break out of a test to carry out manual checks Enter instrument readings and other data e View or print the results e Control the air data test system remotely using the PC Down load a test program to the air data test system e Up load result files from the air data test system The a
17. le Edi Window Help T Record Download warnings 7 A Line 6 PRINT may produce an eror at this ADTS version DEZH 5T E T ADTS iv Simulator Speed 49 if stan 59 Tpm Warning window Simulator window K250 Issue No 2 10 Druck Test Program Manager Version 4 0 User Manual Main window When starting the TPM for the first time the main window shows the software version number From the main window access the main menu or by pointing and clicking select one of the two TPM modes Manual or Program Main menu This menu provides the following facilities File Down loads a previously selected test program file to the ADTS Use the test program editor to select the test program file Up loads result files from the ADTS c Exits the TPM View This menu lists all the TPM window displays that can be selected by the user Options The options menu provides TPM set up and file password protection TPM Setup Click on the Setup menu and the display shows the Setup window TPM Setup x The ADTS software version DK127 needs to be correctly set to permit TPM to down M ADTS Software load the test program into the ADTS DK 127 Version v 4 31 efficiently gt The software version number can be found P C on the ADTS display a few seconds after Port com 1 Power up or Reset by pressing the ABORT keys For later ADTS u
18. nits that use the DK263 software set the version to V 5 10 or higher x Conca Help The Communication Port must be set to the port connecting the data link to the ADTS 11 K250 Issue No 2 Passwords Click on the Password menu and the display shows the Passwords window r Passwords x Program Editor Protection C On Off Password Result Editor Protection C On amp Off Password x Help TPM files program editor or result editor can be protected from change see page 19 Enter the correct password and then click On or Off to switch the protection for either the Program Editor or the Result Editor New password can be set up by clicking on Set Passwords The password menu is the normal Windows type TPM on line Help provides the similar descriptions and procedures found in this user manual and the language manual It also provides the version number of the software required when asking for any technical support K250 Issue No 2 12 Druck Test Program Manager Version 4 0 User Manual Manual mode Inthe TPM manual mode the ADTS can be directly controlled from the PC To control from the PC click on the manual tab on the main window to get the following display Note Check ifthe simulator has been switch on or off E TPM Sf x File View Options Help Display type Manual i Program Alt Manu
19. or Record The record button in tne manual mode window becomes enabled during the manual mode to save the commands executed in a file Note Only use names in the DOS 8 3 format FILENAME EXT The ADTS does not support long file names the TPM does not accept long file names K250 Issue No 2 20 APPENDIX FAR 43 ALTIMETER TEST PROGRAM Summary The FAR 43 test is based on FAR 43 Appendix E 1982 Section a 1 The relevant paragraph numbers are shown after the title of each test description A maximum altitude of 45000 ft has been used The program allows up to five reading sets to be taken such as a combination of pilot copilot and standby altimeters Description Publication K230 TPM Language Reference Manual contains further details of this program including program listings and examples of result printouts Test 1 Case Leak FAR 43 Appendix E 1982 Section a 1 v 1 Altitude increases to 18000 ft at 6000 ft min 2 Pressure stabilises for 1 minute 3 Leak test set for 1 minute 4 Limit of leak rate 100 ft min 5 Altitude decreases to ground zero Test 2 Scale Error Hysteresis and After Effect Table 1 Scale Error FAR 43 Appendix E 1982 Section a 1 i 1 Altitude increases to each set point value column 1 2 The rate of change between set point values set at 6000 ft min reducing rate when nearing set point 3 After 1 minute at each set point user reading recorded column 2 and compared with t
20. rameter is compatible with the software 0 The TPM command ignored by the ADTS The command is only usable when the test program is operated from the PC to control the ADTS remotely 0 The TPM command is not recognised by the ADTS with this software version This is anew command and generates an error at program execution K250 Issue No 2 16 Druck Test Program Manager Version 4 0 User Manual OPERATION Controlling the ADTS in manual mode Setthe TPM to manual mode by pointing and clicking on Manual Make sure the simulator is selected off by setting the ADTS in remote control and clicking in the ADTS box of the simulator window This takes a few seconds The status bar in the main window indicates when the TPM communicates correctly with the ADTS The ADTS should go into remote control mode and display Test Program Manager Active The TPM display should show the ADTS pressure value Note Incorrect communications Check for the following o correct connection of the cable between the ADTS and TPM o correct selection of the COM port in the setup window o other applications using the same COM port o ADTS working correctly disconnect the cable from the hand terminal connector and check if the ADTS goes through all the power up sequences and displays the pressure parameters Loading a test program Click on Test Program in the TPM window or the menu View Program editor to display the Test Program editor Cl
21. rsion 4 0 User Manual CONTENTS Title page INTRODUCTION hited esi gh aed diene nee needed cee ates 1 INSTAELATION s s uere lan nen agree ehren 3 Hardware Requirements v cscecsceseseeececceccesscuescceeedtaeenduegiceectsdeduteetesecvensdcnessteeeneetsnens 3 RG 5 gaunt ee a ae inis 3 Cabl S ugsesecae PER Renee TE HIER Eee ER UITEEER a aa eaaa Eii 3 Printers uenire ee toro ec a ode et iode tae secl ode ose dogs 3 TPM SOFTWARE INSTALLATION eee ene emen eee nere enne nnns 5 Installing the Software essem enm eene 5 CONNECTIONS uester nine eiii pi pra ee eie ree Hei qe de allg 7 ADIS PowerUp voee Remi tert RR ren N Ena ir io nenne 7 USING THE TPM uet iiini dert ne tte ied iiaiai dee 9 Starting Longeeesnmeneenier e HORT a a itin E 9 Setting p NN 9 A brief description of the TPM environment uersnsenessnnnnnnener nennen 10 Main Wind OW u a 11 Mali menu e Sie ce earth thes eer eer N dadeuncdtes tadvecsecgedeeavesde adie 11 Manvallmode 2 2 2 beue tente pact Dept tite de delete 13 Program Mode u ans een a TAE SR AE ea Eee 14 Test program editor window sse 14 Result file editor window s emm 15 Simulator WINK OW 4 een sahen 15 Warning WIDQOW soros na cese Dee e re ede nicest 16 OPERATION a p oc tage peer ree Mien de Ye gode dd aee d ep doe ee 17 Controlling the ADTS in manual mode
22. s of mercury M Mach max maximum min minute or minimum mbar millibar mbar min millibar minute MS DOS Microsoft disk operating System No number para paragraph PC personnel computer Ps pressure static Qc differential pressure ROC rate of climb RS232 serial data transmission standard Sec second TPM Test Program Manager UK United Kingdom Vc velocity airspeed VGA versatile graphics adaptor K250 Issue No 2 iv Druck Test Program Manager Version 4 0 User Manual Glossary Terminology The terminology used in this manual is specific and individual interpretation must not be introduced The terms are defined as follows Adjust To bring to a more satisfactory state to manipulate controls levers linkages etc to return equipment from an out of tolerance condition to an in tolerance condition Align To bring into line to line up to bring into precise adjustment correct relative position or coincidence Assemble To fit and secure together the several parts of to make or form by combining parts Calibrate To determine accuracy deviation or variation by special measurement or by comparison with a standard Check Make a comparison of a measure of time pressure temperature resistance dimension or other quality with a known figure for that measurement Disconnect To detach the connection between to separate keyed or matched equipment parts Dismantle To take apart to the level of the next
23. ssure to the equipment Maintenance The equipment must be maintained using the manufacturer s procedures and should be carried out by authorised service agents or the manufacturer s service departments Technical Advice For technical advice contact the manufacturer or subsidiary A qualified person must have the necessary technical knowledge documentation special test equipment and tools to carry out the required work on this equipment Associated Documents K114 ADTS 405 User Manual K230 TPM Language Reference Manual i K250 Issue No 2 Preliminary SOFTWARE LICENCE Test Program Manager System Software Druck Limited 1992 The licence for this software is a single user licence and the property of Druck Limited The software may not be copied or otherwise reproduced communicated in any way to a third party This licence allows one back up copy to be held by the original licensee for the sole purpose of safeguarding the original software If there are any queries or problems with this software contact us at www gesensing com ISSUE NUMBERS This publication is correct for the following software issue number If the TPM software has a different issue number this publication may not contain the correct description or procedures Refer to the manufacturers for further information Software Numbers K250 DK124 Associated Software DK125 FAR43 Test Program K250 Issue No 2 Druck Test Program Manager Ve
24. the TPM EXE to the hard disk creates a short cut icon on the windows desktop and adds a menu to the task bar 5 K250 Issue No 2 Intentionally left blank K250 Issue No 2 6 Druck Test Program Manager Version 4 0 User Manual CONNECTIONS The TPM cable connections are as follows C N HARDWARE i HANDSHAKE LESE Pin 4 Pin6 Pin 8 Pin 20 Pin 6 Pin 5 CAUTION CoMPLY WITH ALL RELEVANT INSTRUCTIONS IN THE IRCRAFT MAINTENANCE MANUAL OR ComPoNENT MAINTENANCE MANUAL WHEN CONNECTING AND OPERATING THE PITOT STATIC TEST EQUIPMENT Connect the ADTS to the aircraft or instruments under test refer to the appropriate ADTS User Handbook ADTS Power Up Before using the TPM make sure that the aircraft systems are at ground pressure 0 Switch on the ADTS If connected disconnect the hand held terminal and using the TPM cable supplied connect the PC to the control port on the ADTS If required the hand held terminal extension cable may be used Note If the ADTS is already powered up press the ABORT keys to reset the ADTS 7 K250 Issue No 2 Intentionally left blank K250 Issue No 2 8 Druck Test Program Manager Version 4 0 User Manual USING THE TPM Starting After connecting up switch on the PC Start the TPM the same way as starting any Windows based application Double click on the icon that was created by the Install program 0 Locate and double click the TPM E