Home
JOLLY2 - Sion electronics
Contents
1. set 10 of the system s full scale by using the Vv and A keys for example with 3 load cells of 100 kg full scale 100 x 3 300 0 kg 10 of 300 0 kg 30 0 kg Confirm with ENTER the following will appear nU U set the load cell sensitivity expressed in mV V normally 2 000 using the W and A keys Confirm with ENTER the following will appear riSO set the system resolution by using the W and A keys x 1 2 3 4 5 Confirm with ENTER the following will appear unit set the unit of measure using the W and keys 0 kg 1 t Confirm with ENTER the following will appear tArE set the tare value if you knows it by using the W and A keys Confirm with ENTER and C 0 S c message appears again Press MENU to exit TARE ZERO SETTING Make sure that the container is empty and press the 4A key the tArE message will be displayed keeping pressed press the ENTER key at the same time and the tare will be set to zero By pressing after 1 second the tare value appears It is also possible to set the tare to the zero by using the ZERO SETTING EXTERNAL CONTACT ONLY FOR 2SEt OPERATING in this case the LED of DOSA key will start blinking WARNING TURNING OFF THE INSTRUMENT THE DIVISIONS SET TO ZERO BY EXTERNAL CONTACT WILL BE LOST 4 UN INSTRUMENT CALIBRATION CHECK Make sure that the container is empty and that the instrument displays zero Place a significant
2. between the conclusion of the batching and the displayed gross weight then confirm with ENTER the following will appear FiLt filter to reduce the weight oscillations program a value included between 0 1 and max 9 9 seconds Confirm with ENTER to exit By pressing MENU you can exit in any moment 2SCA PROGRAM Unloading batching of 2 products in succession By closing the START contact or the DOSA key the instrument checks that the weight present in the container less the values programmed in the set1 and set2 parameters is not lower than the min weight if it is lower than the min weight the P__ _ message appears for 3 seconds and the batching can not start Then the instrument executes the autotare zero appears and the Led of DOSA key will light up The SET1 relay will be activated the weight begins to increase when the SET1 value less the VOL1 value is reached the instrument will open the SET2 contact when the SET1 value less the fall value is reached the instrument will open the SET1 contact After PAUS time has elapsed the instrument executes the autotare again and closes the SET2 contact when the SET2 value less the VOL value is reached the SET2 contact will be opened After PAUS time has elapsed the gross weight will appears and Led of DOSA key will switch off Press STOP to interrupt the batching in any moment otherwise by pressing DOSA the Alt mess
3. quantity of product in the container at least 50 of the maximum quantity of product that is to be weighed but in any case less than 9 999 and make sure that the instrument displays the correct value If there is a significant difference between the displayed value and effective amount greater than 1 2 check that this is not caused by a mechanical fault and check the electrical connections of the cell and the cell loading position If the difference is not significant but around 1 2 then proceed to CORRECTING DISPLAYED WEIGHT FROM KEYBOARD uN CORRECTING DISPLAYED WEIGHT FROM KEYBOARD When the weight is displayed press Vv The display will show CAL I Hold down the Vv key and press ENTER The display will show the weight value blinking Use the Vv and amp keys to correct it and set the value of the real quantity loaded in the container Press ENTER to confirm The display will show CAL I for an instant then the correct value will appear parameters CELL and nU U Repeat the calibration see Theoretical calibration y If the display shows CAL I this means that incorrect values have been set for the restoring the laboratory setting 2SEt PROGRAM Weight indicator with two alarm thresholds The instrument will be set to zero by pressing the DOSA key or closing the external button NET GROSS the Led of DOSA key will light up this function allows to the operator to load additional qu
4. 99 by using the arrows normally 20 is programmed then confirm with ENTER the following will appear P program the maximum weight max 9999 by using the arrows then confirm with ENTER the following will appear PAUS program the pause time max 9 9 seconds by using the arrows This is the time elapsed between the conclusion of the batching and the displayed gross weight then confirm with ENTER the following will appear FiLt filter to reduce the weight oscillations program a value included between 0 1 and max 9 9 seconds Confirm with ENTER to exit By pressing MENU you can exit in any moment see 1SCA PROGRAM Unloading batching of 1 product with two speeds By closing the START contact or the DOSA key the instrument checks that the weight present in the container less the value programmed in the set1 parameter is not lower than the min weight if it is lower than the min weight the P__ _ message appears for 3 seconds and the batching can not start Then the instrument executes the autotare zero appears and the Led of DOSA key will light up The SET1 and SET2 relays will be activated the weight begins to increase when the SET1 value less the slow value is reached the instrument will open the SET2 contact when the SET1 value less the fall value is reached the instrument will open the SET1 contact After PAUS time has elapsed the gross weight will appears and Led
5. ELL SIGNAL TEST mV INPUTS OUTPUTS TEST Switch the instrument on by keeping pressed the A key the LOAD CELLS VALUE expressed in mV will appear Press A the 1 message appears press ENTER to close open the relay 1 by u ensuring the changeover from to to closed when the relative input changes from open Press A the 2 message appears press ENTER to close open the relay 2 by oy xs ensuring the changeover from to to closed when the relative input changes from open Press A to exit until the weight is displayed INSTRUMENT START UP Switch on the instrument and wait for about 5 minutes until all the components will reach a steady temperature Verify that the displayed weight is positive and that it increases if one subjects the container to a force weight In case a negative value is displayed check the load cells connections and their correct installation direction of charge Check also that the container is correctly installed tubes position links etc If the JOL 2 message appears select the desired operating mode see page 1 THEORETICAL INSTRUMENT CALIBRATION Switch off the instrument then turn on by keeping pressed the MENU key the C 0 S c message appears press ENTER and the following will appear dECP set the number of decimals max 3 decimals using the W and amp keys Confirm with ENTER the following will appear CELL
6. ENGLISH Se ENGLISH SS ENGLISH SS ENGLISH Installation user s manual version 3 3 Warning electrical scheme DATA TO BE FILLED OUT BY modified THE INSTALLER Page 1 JANUARY 2005 6 different operating modes selectable OUTPUT wha kd JOLLY C 2004 108 EC EMC 2006 95 EC LVD ENGLISH ENGLISH Se ENGLISH SS ENGLISH TABLE OF CONTENTS SELECTING THE OPERATING MODE icaissiwccssenscutessutndsituntensusbsvsussscvavaied aikcustassccarsindidtnshnaasonGatascsnopeduiunane 1 TECHNICAL PEAT URE Sui cocccesssuscss tus atcccasvescatustancubtntasnd el cssueasianade sash tcnasaninenacestctascatatisnnearestuneaata Aioni g 2 ELECTRICAL CONNECTIONS s sisien sasien acinssraicarauascaceinipssduisinanissisnadwavsataaasnsaceudtusihelisnssiuasdssbakdanboiasivninn 2 TEST LOAD CELL SIGNAL MV INPUTS OUTPUTS ssssssssssssunnsnnnnnnunnunennnnnnnnnnnnnunnnnnnnnnnnnnnnnennnnnnnnn nne 3 INSTRUMENT START UP ara cuicntepasiduobevcivssivessaniniceaia bat eacschinavaustipnsadicinstint Ch Sa EEan E aas inanan ain 4 THEORETICAL INSTRUMENT CALIBRATION ccssssssssssssssesesessesssnrseesteeeeenteassnsseeasensseenteneanesneaeensnneasens 4 TARE ZERO SETTING sani sisi snwasticcacien stein cabascusndic tzihshcatunitpasati dane ear aai Avin eaaa naa ATS 4 INSTRUMENT CALIBRATION CHECK AND CORRECTING DISPLAYED WEIGHT nsss 5 WEIGHT INDICATOR WITH TWO ALARM THRESHOLDS sssssssenunensununnnnnunnnnnunonnnnnnnonnnnonnnnennnnnnnnnnnnnnnnnne 6 LOADING BATC
7. HING OF 1 PRODUCT WITH TWO SPEEDS sccssssssessssessesessnsseeesenrsneeneseenenessensateas 7 LOADING BATCHING OF 2 PRODUCTS IN SUCCESSION ssssssssssssssesesssssesesssssnenteneensneeneansnteeseneaeeas 8 UNLOADING BATCHING OF 1 PRODUCT WITH TWO SPEEDS scsssssssssssesessessestsnrsnsesensseesnessensstees 9 UNLOADING BATCHING OF 2 PRODUCTS IN SUCCESSION scssssssssssssrsssesssrsnsesssnsnssneensnnsneeteasens 10 WEIGHT INDICATOR WITH ONE ALARM THRESHOLD s sssssssssssssssesssessessssesesenensneeeeansneeseeneaneees 11 LEGENDA Caution High Voltage Caution This operation has to be carried out only by specialized personnel Pay particular attention to the following indications E S GUARANTEE 24 months from the delivery document date The guarantee covers only defected parts and includes the replacement parts and labour All shipping and packing costs are paid by the customer It is possible to have the repair in guarantee on condition that the returned product has not been transformed damaged or repaired without authorization No guarantee is applicable on returned products without the original label and or serial number No guarantee against misuse Batteries Laumas provides 1 year guarantee from the date of delivery note against material defects or battery manufacturing faults Disposal of Waste Equipment by Users in Private Household in the European Union your responsibility to dispose of your waste
8. TING TEMPERATURE 10 50 C ELECTRICAL CONNECTIONS WARNING The procedures here below described have to be carried out by AN specialized personnel only Be sure to switch off the instrument before carrying out any connections at all Connect the load cells by means of a terminal board in a water proof junction box connecting the leads having the same colour perform the same operation for the shields By means of a shielded 4 wire cable with a section not lower than 0 5 mmq connect the terminal board to the JOLLY instrument The cable routing shall be far away from the power cables and possibly protected by a metal pipe Connect the r Shielded cable to the ground 2 O A_ EXCITAT EXCITAT SIGNAL SIGNAL SET2 SLOW For 2SET version i NET GROSS gt iSTOP I al T E a L I ESRR 11 12 13 1441516 17118 LIN 4 5 6 7 8 9 10 E ft SETI E TT 230 VAC Gr O DISPLAYING ALARMS C C It appears when a short circuit happens on load cell excitation cores and when the displayed weight is higher in negative than the absolute valueprogrammed in the A cc constant SEGn It appears when one or two signal wires are disconnected AL It appears when one or two excitation wires are disconnected CELL It appears when the load cell response signal core is higher than 20 mV U During the alarms displaying outputs will be open LOAD C
9. age appears the batching will be temporarily interrupted press the ENTER key to start again the batching by pressing the DOSA key again you can stop the batching definitely 2SCA PROGRAMMING Press the MENU key only if the Led of DOSA key is switch off the relevant Led begins to blink the following will appear SEt 1 program the weight for SET 1 max 9999 by using the arrows keys then confirm with ENTER the following will appear SEt 2 program the weight for SET 2 by using the arrows keys then confirm with ENTER the following will appear VOLO set the fall value product in fall at the stop of the extractor O manual fall or 1 automatic fall The instrument will calculate on itself the fall value by using the arrows keys then confirm with VOL 1 program the fall value by using the arrows if the automatic fall has been selected the fall value calculated by the instrument appears If the power break down this value will be lost Confirm with ENTER the following will appear VOL 2 value of fal 2 Confirm with ENTER the following will appear P _ _ _ program the min weight max 9999 by using the arrows normally 20 is programmed then confirm with ENTER the following will appear PAUS program the pause time max 9 9 seconds by using the arrows This is the time elapsed between the conclusion of the batching and the displayed gross weight then confi
10. antities of product To display the gross weight press again the DOSA key or closing the external button NET GROSS for more 3 seconds the related Led will light off The condition of relays changes because of gross weight For weight lower than the programmed SET values relays are activated For weight equal or greater than the programmed SET values relevant relays are deactivated The relay changeover is performed for decreasing weight according to the hysteresis values VOL 1 e VOL 2 If SEt 1 100 and VOL 1 10 an increasing weight will set the relay to 100 a decreasing weight will set the relay to 90 2SEt PROGRAMMING Press the MENU key the related Led will blink the following will appear SEt 1 program the weight for SET 1 max 9999 by using the and A keys then confirm with ENTER the following will appear SEt 2 program the weight for SET 2 max 9999 by using the VY and A keys then confirm with ENTER the following will appear VOL 1 program the istheresys for SET 1 by using the Tano amp keys the condition of the relay will change for decreasing weight when the weight will be equal to the programmed SET 1 value SEt 1 minus the one programmed in this constant VOL 2 program the istheresys for SET 2 by using the Vand A keys then confirm with ENTER the following will appear FiLt program the filter to reduce the weight oscillation
11. appears and Led of DOSA key will switch off Press STOP to interrupt the batching in any moment otherwise by pressing DOSA the Alt message appears the batching will be temporarily interrupted press the ENTER key to start again the batching by pressing the DOSA key again you can stop the batching definitely 2CAr PROGRAMMING Press the MENU key only if the Led of DOSA key is switch off the relevant Led begins to blink the following will appear SEt 1 program the weight for SET 1 max 9999 by using the arrows keys then confirm with ENTER the following will appear SEt 2 program the weight for SET 2 by using the arrows keys then confirm with ENTER the following will appear VOLO set the fall value product in fall at the stop of the extractor O manual fall or 1 automatic fall The instrument will calculate on itself the fall value by using the arrows keys then confirm with VOL 1 program the fall value by using the arrows if the automatic fall has been selected the fall value calculated by the instrument appears If the power break down this value will be lost Confirm with ENTER the following will appear VOL 2 value of fall 2 Confirm with ENTER the following will appear AtAr program 0 autotare disabled or 1 autotare enabled by using the arrows then confirm with ENTER the following will appear P _ _ _ program the min weight max 99
12. equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at this time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your Dz This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste Instead it is waste equipment for recycling please contact your local city office your household waste disposal service or the reseller THE INSTRUMENT IS SUPPLYED WITH CALIBRATION 10000 KG SENSITIVITY 2mV V RESOLUTION 1 OPERATING MODE SELECTION BY THE INSTALLER SELECTING THE OPERATING MODE Switch off the instrument then turn on by keeping pressed VY and A at the same time the JOL 2 0 message appears you can select the following operating mode by using the arrows 1 2SEt Weight indicator with two alarm thresholds normally activated 2 1CAr Loading batching of 1 product with two speeds 3 2CAr Loading batching of 2 products in succession 4 1SCA Unloading batching of 1 product with two speeds B 2SCA Unloading batching of 2 products in succession 6 1SEt Weight indicator with one alarm threshold normally deactivated Then press ENTER to restore the instrume
13. he arrows This is the time elapsed between the conclusion of the batching and the displayed gross weight then confirm with ENTER the following will appear FiLt filter to reduce the weight oscillations program a value included between 0 1 and max 9 9 seconds Confirm with ENTER to exit By pressing MENU you can exit in any moment Eir ae 2CAr PROGRAM Loading batching of 2 products in succession By closing the START contact or the DOSA key the instrument checks that the weight in the container less the weight set in set1 and set2 is not smaller than the minimum set weight if it is higher than the max weight the P message appears for 3 seconds and the batching can not start Then the instrument checks that the weight present in the container negative or positive is lower than the minimum weight in this case P_ _ _ appears for 3 seconds and the batching can not start Once all the conditions are met the instrument executes the autotare if enabled zero appears and the Led of DOSA key will light up The SET1 relay will be activated When the SET1 value less the VOL1 value is reached the instrument will open the SET1 contact After PAUS time has elapsed the instrument executes the autotare again and closes the SET2 contact when the SET2 value less the VOL2 value is reached the SET2 contact will be opened After PAUS time has elapsed the gross weight will
14. ng by pressing the DOSA key again you can stop the batching definitely 1Car PROGRAMMING Press the MENU key only if the Led of DOSA key is switch off the relevant Led begins to blink the following will appear SEt 1 program the weight for SET 1 max 9999 by using the arrows keys then confirm with ENTER the following will appear LEnt Set 2 program the slow value by using the arrows keys then confirm with ENTER the following will appear VOLO set the fall value product in fall at the stop of the extractor O manual fall or 1 automatic fall The instrument will calculate on itself the fall value by using the arrows keys then confirm with ENTER the following will appear VOL 1 program the fall value by using the arrows if the automatic fall has been selected the fall value calculated by the instrument appears If the power break down this value will be lost Confirm with ENTER the following will appear AtAr program O autotare disabled or 1 autotare enabled by using the arrows then confirm with ENTER the following will appear P _ _ _ program the min weight max 9999 by using the arrows normally 20 is programmed then confirm with ENTER the following will appear P program the maximum weight max 9999 by using the arrows then confirm with ENTER the following will appear PAUS program the pause time max 9 9 seconds by using t
15. nts the selected operating mode appears followed by the version s number If you press ENTER while JOL 2 0 is displayed the JOL 2 message will appear again and the instrument willbe DEACTIVATED In case of automatic reset when the instrument switches on the JOL 2 message appears ad no command is accepted select the operating mode again TO BE FILLED OUT BY THE INSTALLER ALSO THE INSTRUMENT S LABEL aset _ icar _ 2car ascal ascal ise CELL nU U rlSO dECP TECHNICAL FEATURES The instrument is able to read up to 19 999 divisions when the 9 999 value is reached the visualized weight will restart again from 0 and will start blinking in order to inform that the above mentioned value has been passed POWER 230 Vac 10 50 60 Hz 5 VA consumption LOAD CELLS SUPPLY 5 Vdc 60 mA LOAD CELL CONNECTIONS max 4 load cells 350 ohm or max 8 load cells 700 ohm INTERNAL DIVISIONS 20000 DISPLAY RANGE 999 19999 MEASURING RANGE 4mV 16 5 mV READING RESOLUTION x1 x2 x3 x4 x5 CONVERSION RATE 10 readings sec LOAD CELLS SIGNAL READING mV see Test page 2 connection checks LOGIC OUTPUTS 2 RELAY free contacts max 115Vca 2A LOGIC INPUTS 2 UNIT OF MEASURE kg or t FRONT PANEL PROTECTION IP64 DISPLAY semi alphanumeric display 4 digits 20 mm in seven segments DECIMAL POINT selectable xxxx XXX X XX XX X XXX HUMIDITY condensate free max 90 STORAGE TEMPERATURE 20 70 C OPERA
16. of DOSA key will switch off Press STOP to interrupt the batching in any moment otherwise by pressing DOSA the Alt message appears the batching will be temporarily interrupted press the ENTER key to start again the batching by pressing the DOSA key again you can stop the batching definitely 1SCA PROGRAMMING Press the MENU key only if the Led of DOSA key is switch off the relevant Led begins to blink the following will appear SEt 1 program the weight for SET 1 max 9999 by using the arrows keys then confirm with ENTER the following will appear LEnt Set 2 program the slow value by using the arrows keys then confirm with ENTER the following will appear VOLO set the fall value product in fall at the stop of the extractor O manual fall or 1 automatic fall The instrument will calculate on itself the fall value by using the arrows keys then confirm with ENTER the following will appear VOL 1 program the fall value by using the arrows if the automatic fall has been selected the fall value calculated by the instrument appears If the power break down this value will be lost Confirm with ENTER the following will appear P__ _ program the min weight max 9999 by using the arrows normally 20 is programmed then confirm with ENTER the following will appear PAUS program the pause time max 9 9 seconds by using the arrows This is the time elapsed
17. rm with ENTER the following will appear FiLt filter to reduce the weight oscillations program a value included between 0 1 and max 9 9 seconds Confirm with ENTER to exit By pressing MENU you can exit in any moment 10 1SEt PROGRAM Weight indicator with an alarm threshold U This program not use inputs terminals 11 12 14 and the second relay terminals 6 7 8 The condition of the SET1 relay changes because of gross weight For weight lower than the programmed SET value relay is deactivated For weight equal or greater than the programmed SET the relay is activated 1SEt PROGRAMMING Press the ENTER key the related Led will blink the following will appear SEt 1 program the weight for SET1 max 9999 by using the A and A keys then confirm with ENTER the following will appear FiLt program the filter to reduce the weight oscillations set a value included between 0 1 and 9 9 seconds by using the W and the amp keys Confirm with ENTER to come back to the weight displaying 11
18. s set a value included between 0 1 and 9 9 seconds by using the W and the amp keys Confirm with ENTER to exit By pressing MENU you can exit in any moment 1Car PROGRAM Loading batching of 1 product with two speeds By closing the START contact or the DOSA key the instrument checks that the weight in the container less the weight set in set is not smaller than the minimum set weight if it is higher than the max weight the P message appears for 3 seconds and the batching can not start Then the instrument checks that the weight present in the container negative or positive is lower than the minimum weight in this case P_ _ _ appears for 3 seconds and the batching can not start Once all the conditions are met the instrument executes the autotare if enabled zero appears and the Led of DOSA key will light up The SET1 and SET2 relays will be activated the weight increase is displayed while the weight is extracted when the SET1 value less the slow value is reached the instrument will open the SET2 contact when the SET1 value less the fall value is reached the instrument will open the SET1 contact After PAUS time has elapsed the gross weight will appears and Led of DOSA key will switch off Press STOP to interrupt the batching in any moment otherwise by pressing DOSA the Alt message appears the batching will be temporarily interrupted press the ENTER key to start again the batchi