Home
INSTR UCTION AND USE MANU AL
Contents
1. exemption requirements of the standard EN61326 1 but it cannot be excluded that malfunctions could occur in extreme cases due to particular situations The installer has the task of checking that the disturbance levels are within the requirements of the standards CONDUCTION AND MAINTENANCE The following maintenance operations should be performed every week check the condition of the hydraulic connection tubes sleeves and joints check that the terminals to which the equipment is connected are tight check the condition of the supply cable sheath If the mains power supply cable is damaged it has to be replaced by the manufacturer Every year the plant should be descaled and the operating thermostat should be checked UNLESS WE MAKE A WRITTEN DECLARATION STATING THE CONTRARY THIS HEATER IS NOT SUITABLE FOR USE AS A CRITICAL COMPONENT IN EQUIPMENT OR PLANTS RESPONSIBLE FOR KEEPING PERSONS OR OTHER LIVING BEINGS ALIVE Any use which differs from that which is indicated in this instruction and user manual must be authorized by the manufacturer YOUR ELECTRICAL TECHNICIAN CAN ASK US ANYTHING ABOUT THIS HEATER BY TELEPHONING ONE OF OUR TECHNICIANS E ELCOS SRL Parma GB RA 0500 1000 1500 3 ORDERING INFORMATION TECHNICAL DATA MAINS POWER SUPPLY RA 0500 230VAC 10 50 60 Hz RA 1000 RA 1500 Code 00706167 DIELECTRIC STRENGTH BETWEEN 2000V x 1 MINUTE TERMINALS AND CONTACTS 00706167 TYPE RA 0500 W RA 1000 4000W W RA 1500
2. 1500 W SERVICE CONTINOUS OPERATIONAL THERMOSTAT NON ADJUSTABLE DISENGAGED HEATING a 53 C 5 ENGAGED HEATING a 33 C 5 CONNECTION CABLES FROR 450 750 V DEGREE OF PROTECTION IP54 TEMPERATURE LIMITS 20 C 120 C ONLY IF SUPPLIED WEIGHT 1270 gr CONFORMITY DECLARATION C The company Elcos s r l assumes full responsibility for declaring that the equipment tpe RA 0500 RA 1000 RA 1500 installed and used in the ways and for the purposes described in the user instruction manual complies with the essential requirements and other relevant provisions laid down by the following directives 2006 95 CE related to the electrical materials destined to be used within certain voltages limits 2004 108 CE related to the electromagnetic compatibility and that repeals the directive 89 336 CEE 2011 65 UE on the restriction of the use of certain hazardous substances in electrical and electronic equipment because it is built and functions in accordance with the harmonized Standards EN 50081 1 EN 50082 2 EN60204 1 EN 60529 Parma 25 06 2013 3 ELCOS Presiden Fa Via Arandora Star 28 a on a4 Ea t 143122 PARMA ITALIA Tel 39 0521 772021 Fax 39 0521 270218 7 E mail info elcos it HTTP Avww elcos it Margini Enzo a E ELCOS SRL Parma GB RA 0500 1000 1500
3. WATER HEATERS o Suitable for heating water in diesel engines with closed circuit cooling TYPE RA 0500 TT 500 W P HOT TYPE RA 1000 1000 W TYPE RA 1500 1500 W DRAIN PLUG COLD om WATER IN LENGTH OF CABLE 3 m 230 Vac COOLING LIQUID OPTIMUM DIELECTRIC STRENGTH 2000V TEMPERATURE MAINTAINED BY AN EASY CONNECTION VIA CABLE INTERNAL THERMOSTAT CAN BE MOUNTED DIRECTLY ONTO THE ENGINE DIMENSIONS INSTRUCTION AND USE MANUAL Hose end fitting for 016 hose internal PARMA ELCOS amp L pot Os21 T72021 ax oe 0521 270218 l info elcos it Piweww elcos it 1 E ELCOS SRL Parma GB RA 0500 1000 1500 INSTALLATION O ae MOUNTING DIRECTION lie WATER SOCKET SHOULD BE AS HIGH AS POSSIBLE COLD WATER SOCKET SHOULD BE AS LOW AS POSSIBLE Oa POINT B MUST BE BELOW POINT A TO AVOID SIPHONS BEING PRODUCED THERE SHOULD BE NO CURVES IN THE FLEXIBLE TUBES CIRCULATION PROBLEMS Le UNUU UY p lt BEFORE INSTALLING THE HEATER CLEAN THE COOLING CIRCUIT OPERATION The heater prevents the cooling circuit temperature from falling below a certain value This value is regulated by an internal thermostat The water circulates using the thermosiphon principle HOT WATER OUT CONNECTIONS POWER SUPPLY 230 VAC LENGTH OF CABLE 3m The installer has to mount the mains power supply circuit overcurrent prot
4. ection fuses 10A 250V or 2 automatic switch 10 A E ELCOS SRL Parma GB RA 0500 1000 1500 WATER HEATERS _ TYPE RA 0500 RA 1000 RA 1500 Used to pre heat the water cooled Diesel engine heating the cooling liquid Designed to be installed also on board the machine Warning adhere closely to the following advice Take great care to connect correctly the conductors coming out of the equipment Adhere closely to the installation indications on page 2 Never supply the equipment unless it has liquid inside During operation the device is at high temperature 70 C During operation if it is necessary to open the radiator plug protect with Individual Safety Devices from any boiling water sprays Do not use calcareous water as cooling liquid Perform discharge actions only when device is cold and unsupplied THIS HEATER IS NOT SUITABLE FOR OPERATING IN THE FOLLOWING CONDITIONS where the environmental temperature is outside the limits indicated in the technical sheet on page 4 where there are high levels of pollution caused by dust smoke vapour salts and corrosive or radioactive particles where attacks from mould or small animals are possible where there is the risk of fire or explosions where the panel can receive strong vibrations or knocks ELECTROMAGNETIC COMPATIBILITY This equipment functions correctly only if inserted in plants which conform with the CE marking standards it meets the
Download Pdf Manuals
Related Search
Related Contents
給水のしかた Festool Cordless Drill 564274 User's Manual Falcon T Series Service Manual Installation instructions Ewent EW3576 mobile headset Novosoft Mobile Instant Messenger GRAFIK EYe QS Control UNit: CE CM-3600A/CM-3610A Copyright © All rights reserved.
Failed to retrieve file