SDS Series User Manual

image

Contents

1. Figure 7 2 Waveform of Gain Measurement Example 3 Capturing a Single Signal It s quite easy to use Digital Oscilloscope to capture non periodic signal such as a pulse and burr etc But the common problem is how to set up a trigger if you have no knowledge of the signal For example 1f the pulse is the logic signal of a TTL level the trigger level should be set to 2 volts and the trigger edge be set as the rising edge trigger With various functions supported by our Oscilloscope user can solve this problem by taking an easy approach First to run your test using auto trigger to find out the closest trigger level and trigger type this helps user to make few small adjustments to achieve a proper trigger level and mode Here is how we achieve this The operation steps are as follows 1 Set the probe menu attenuation coefficient to 10X and that of the switch in the probe to 10X see How to Set the Probe Attenuation Coefficient on P14 2 Adjust the VOLTS DIV and SEC DIV knobs to set up a proper vertical and horizontal ranges for the signal to be observed 3 Press the Acquire button to display the Acquire menu 4 Press the H1 button to display the Acquire Mode menu 5 Press the F2 button to choose Peak detect 81 7 Demonstration 6 Press the Trigger Menu button to display the Trigger menu 7 Press the H1 button to display the Trigger Type menu 8 Press the F1 to choose Single as the type 9 Turn the M knob to ch
2. FFT function in this oscilloscope transforms 2048 data points of the time domain signal into its frequency components mathematically and the final frequency contains 1024 points ranging from OHz to Nyquist frequency Taking the FFT operation for example the operation steps are as follows 1 Press the Math button and call out the Math menu 2 Press the H2 button and call out the FFT menu 3 Press the F1 button to choose CH1 as the source 4 Press F2 button the windows item will display at the left of the screen turn the M knob to select Window including Rectangle Hamming Hanning and Blackman 5 Press F3 button to choose the Format including dB Vrms 6 Press F4 button the zoom window will display at the left of the screen turn the M knob to zoom in or out the wave of the multiple including x1 x2 x5 x10 To select the FFT window m There are four FFT windows Each one has trade offs between frequency resolution and magnitude accuracy What you want to measure and your source signal characteristics help you to determine which window to use Use the following guidelines to select the best window 28 5 Advanced User Guidebook Type Characteristics Window Best solution for frequency worst for magnitude Best type for measuring the frequency spectrum of nonrepetitive signals and measuring frequency components near DC Recommend to use for Rectangle Transients or bursts the signal level before and after the event
3. refer to Signal on P61 6 EXT Trigger Input 7 Signal Input Channel 8 Menu off Left Side Panel l 2 Figure 4 2 Left side panel 1 Power switch represents power ON O represents power OFF 2 AC power input jack Right Side Panel m Ww Nh Figure 4 3 Right side panel 1 USB Host port It is used to transfer data when external USB equipment connects to the oscilloscope regarded as host device For example upgrading software by USB 7 4 4 Junior User Guidebook flash disk needs to use this port USB Device port It is used to transfer data when external USB equipment connects to the oscilloscope regarded as slave device For example to use this port when connect PC to the oscilloscope by USB COM VGA port Optional To connect the oscilloscope with external equipment as serial port or to connect the oscilloscope with a monitor or a projector as VGA output for the model with V LAN port the network port which can be used to connect with PC Rear Panel 1 2 ae SS Figure 4 4 Rear Panel The port of trigger signal output amp Pass Fail output Handle Air vents Foot stool which can adjust the tilt angle of the oscilloscope Ground connection 4 Junior User Guidebook Control key and knob Area Row N gt VERTICAL cage WHET AL ig He imon AMONI TE Tiga wr Hti F E T Figure 4 5 Keys Overview Menu option setting H1 H5 Menu option setting F
4. Press F5 button to switch between each byte turn the M knob Net mask to change value 0 255 Save the current settings and prompt reset to update the config e Signal Only SDS7072 V has this menu You can adjust the signal parameters of 5 Probe Compensation in Figure 4 1 Front panel Press the Utility button and turn the M knob to select the Signal to go to the following menu Figure 5 50 Signal menu The description of Signal menu is shown as the follows Function Settin Description Turn the M knob to change value 1KHz 100KHz Set Turn the M knob to change value 5 95 Set Frequency to 1KHz set Duty to 50 61 5 Advanced User Guidebook How to Measure Automatically Press the Measure button to display the menu for the settings of the Automatic Measurements The oscilloscopes provide 20 parameters for auto measurement including Vpp Vmax Vmin Vtop Vbase Vamp Vavg Vrms Overshoot Preshoot Freq Period Rise Time Fall Time Delay A gt BF Delay A B t Width Width Duty Duty That s 10 voltage and 10 time measurements in all The menu is displayed as Figure 5 51 Figure 5 51 Measure Menu The Automatic Measurements menu is described as the following table Function Menu Setting Type e Press F1 show the measure types Select the source o CH i CH2 Add Show all Show all the measures on the screen Remove all the measures Turn the M knob select the
5. corrosive chemical cleaning agent Warning Before power on again for operation it 1s required to confirm that the instrument has already been dried completely avoiding any electrical short circuit or bodily injury resulting form the moisture 94 10 Appendix Appendix C Battery Using Guide Battery level indicator include a al i and 0 Chis T a O EA l a E ee e A eh Pee A ee eke E is A E a a E E se E A ee E ee E TO ee a a 8 O E N a E SOKS s M 1 0Oms _f0 00mv Depth 1K f f f f o Display Figure 10 1 Battery level indicator Charging the oscilloscope Connect the power cord to a power source Turn on the Power Switch Button on the left side make sure the side is pressed down Yellow light of the indicator on the front panel means the battery is being charged Once the battery is full the indicator will become green The lithium battery may not be fully charged when you receive it Please charge the battery for 12 hours before the first use You battery can last 4 hours depending on your usage after fully charged There will have battery power indication show on the top of panel when oscilloscope power supplied by the battery 1f no indication has appeared see Display on P57 E a and L indicates the level of your battery When shows it means the power can only supply for 5 minutes maximum Note To avoid overheat of battery during charging the ambient temperature is
6. on left of trigger point DSO continues to acquire data while waiting for trigger condition to occur Once it detects a trigger it will acquire enough data continuously to draw the waveform on right of trigger point Trigger control area consists of 1 knob and 3 menu keys TRIG LEVEL The knob that set the trigger level press the knob and the level will be cleaned to Zero 50 The instant execute button setting the trigger level to the vertical midpoint between the peaks of the trigger signal Force Force to create a trigger signal and the function is mainly used in Normal and Single mode Trigger Menu The button that activates the trigger control menu Trigger Control The oscilloscope provides two trigger types single trigger and alternate trigger Single trigger Use a trigger level to capture stable waveforms in two channels simultaneously Alternate trigger Trigger on non synchronized signals The Single Trigger and Alternate Trigger menus are described respectively as follows Single trigger Single trigger has four modes edge trigger video trigger slope trigger and pulse trigger Edge Trigger It occurs when the trigger input passes through a specified voltage level with the specified slope Video Trigger Trigger on fields or lines for standard video signal Slope Trigger The oscilloscope begins to trigger according to the signal rising or falling speed Pulse Trigger Find pulses with certain widths
7. tip will be given to show NO RULE SAVED 4 Under the status of stop data comparing will stop and when it goes on running the number of Pass Fail will increase from the former number not from zero 5 When the waveform playback mode is on Pass Fail is used to test the played back waveform specially e Output Press the Utility button and turn the M to select the Output to go to the following menu Figure 5 48 Output menu The description of Output menu is shown as the follows EON Settin Description Menu 5 p Type Trig level Output trig signal synchronously YP Pass fail Output High Level when Pass and Low Level when Fail 60 5 Advanced User Guidebook e LAN Set Using the LAN port the oscilloscope can be connected with a computer directly or through the router to connect The network parameters can be set in the menu below Refer to Using LAN Port on P75 for the operation steps Press the Utility button and turn the M knob to select the LAN Set to go to the following menu Figure 5 49 LAN Set menu The description of LAN Set menu is shown as the follows Function pe Press F1 button to switch between each byte turn the M knob IP to change value 0 255 Turn the M knob to change value 0 4000 Meroate Press F3 button to switch between each byte turn the M knob Set i to change value 0 255 Press F4 button to switch between each byte turn the M knob Phy addr to change value 0 FF
8. 65 5 Advanced User Guidebook ponsi Switch off the cursor measurement en Display the voltage measurement cursor and menu Time Display the time measurement cursor and menu Source CH1 Display the channel generating the waveform to CH2 which the cursor measurement will be applied When carrying out the cursor measurement the position of Cursor 1 can be adjusted with the VERTICAL POSITION knob of Channel 1 and that of Cursor 2 can be adjusted with the VERTICAL POSITION knob of Channel 2 Perform the following operation steps for the voltage cursor measurement of the channel CH1 1 Press Cursor and recall the Cursor Measure menu 2 Press the H2 button and choose CH1 for Source 3 Press the H1 button the Type menu will display at the right of the screen Then press the F2 button to choose Voltage for Type with two purple dotted lines displayed along the horizontal direction of the screen which indicating Cursorl and Cursor2 4 According to the measured waveform adjust the positions of Cursorl and Cursor2 by turning the VERTICAL POSITION knob of CH1 and CH2 Cursor increment window at the left bottom of waveform shows absolute value of D value of cursor 1 and cursor 2 and the present position of the two cursors see Figure 5 56 yil 116 00v 72 104 00v 7 12 5MS s M 500us TRA 100K f Figure 5 56 Waveform of Voltage Cursor Measurement Carry out the following operation steps for the time cursor measurement
9. 6GS e CH co Input Input impedance 1MQ 2 in parallel with 1OpF 5pF Probe attenuation 1X 10X 100X 1000X factor Max input voltage 400V PK PK DC AC PK PK 88 9 Technical Specifications Performance Characteristics Instruction pawn Noo p not including SDS6062 V 5OHz 100 1 1OMHz 40 1 150ps sii a D sin x x Dual CH lt Max Single CH lt Max sampling rate Channel channel isolation Time delay between channel typical Ne Sampling rate range SDS8102 V SDS8202 V SDS8302 SDS9302 Interpolation Horizontal PE enw System Dual CH Single CH Dual CH SDS7072 V SDS7102 V Single CH Dual CH SDS8102 V Max Record length Single CH Dual CH SDS8202 V SDS8302 Dual CH OO O Single CH lt Max sampling rate lt 500MS s 10M 1GS s 10K alele BREBEREDEBEE 9 Technical Specifications Performance Characteristics 7 n Sns div 100s div D 2 Peon step by l 2 5 2ns div 100s div D 2 Pee step by l1 2 5 2ns div 100s div DS7102 codon step by l 2 5 Scanning speed ae SDS8102 V 2ns div 100s div S div step by l 2 5 Ins div 100s div SDS8202 V tay by 1 2 5 Ins div 100s div SDS8302 i spseso step by 1 2 5 Ins div 100s div D 2 pean step by l 2 5 Sampling rate 100ppm relay time accuracy Single Instruction 1GS s 1 25GS s a 1G8h 2GS s 2 5GS s nos lt 400MS s_ 10
10. General Inspection After you get a new SDS series oscilloscope it is recommended that you should make a check on the instrument according to the following steps 1 Check whether there is any damage caused by transportation If it is found that the packaging carton or the foamed plastic protection cushion has suffered serious damage do not throw it away first till the complete device and its accessories succeed in the electrical and mechanical property tests 2 Check the Accessories The supplied accessories have been already described in the Appendix A Enclosure of this Manual You can check whether there is any loss of accessories with reference to this description If it is found that there is any accessory lost or damaged please get in touch with the distributor of Lilliput responsible for this service or the Lilliput s local offices 3 Check the Complete Instrument If it is found that there is damage to the appearance of the instrument or the instrument can not work normally or fails in the performance test please get in touch with the Lilliput s distributor responsible for this business or the Lilliput s local offices If there is damage to the instrument caused by the transportation please keep the package With the transportation department or the Lilliput s distributor responsible for this business informed about it a repairing or replacement of the instrument will be arranged by the Lilliput How to Implement the Fun
11. Set Connect using to LAN About the IP the first three bytes is same as the IP in the step 2 the last byte should be different Here we set it to 192 168 1 72 The range of the port value is 0 4000 but the port which under 2000 is always be used so it is Suggested to set it to the value above 2000 Here we set it to 3000 at Ports settings pe comect usine R 9 e IPC i92 166 1 72 gt porti 3000 Custom USE Transfer Instructions Some Types can choose to get bin bmp or deep memory data faveF orm Image High Memory Depth Get Image File bmp Setting Keep Getting Delay ms 2000 Save data file automatically to below directory For there is a limit mmber of files in one single directory of Windows File System FATI6 FATS NIFS F the mmber of files to be saved 15 not certain it 15 recommended to choose a directory in HIFS disk drive turn off the storage channels in device and use short directory path to save more files Get Data now Keep Getting now Figure 6 6 Set the network parameters of the OWON Oscilloscope Software T1 6 Communication with PC 4 Set the network parameters of the oscilloscope In the oscilloscope press the Utility button and press H1 button turn the M knob to select the LAN Set press the H2 button the set menu is displayed on the right Set the IP and the Port to the same value as the Ports settings in the software in step 3 The Netgate and Net ma
12. Stop Check whether Normal or Signal is chosen for Polarity in the TRIG MODE menu and the trigger level exceeds the waveform range If it is make the trigger level is centered in the screen or set the trigger mode as Auto In addition with the Autoset button pressed the setting above can be completed automatically 6 The displaying of waveform seems getting slow after increasing AVERAGE value in Acqu Mode see How to Implement Sampling Setup on P44 or a longer duration is set in the Persist in Display see Persist on P47 It s normal as the Oscilloscope is working hard on many more data points 87 9 Technical Specifications 9 Technical Specifications Unless otherwise specified the technical specifications applied are for SDS series only and Probes attenuation set as 10X Only if the oscilloscope fulfills the following two conditions at first these specification standards can be reached E This instrument should run for at least 30 minutes continuously under the specified operating temperature m If change of the operating temperature is up to or exceeds 5C do a Self calibration procedure see How to Implement Self calibration on P15 All specification standards can be fulfilled except one s marked with the word Typical Bandwidth Mode Normal Peak detect Averaging 500MS s Dual CH 500MS s Single CH Dual CH 500MS s ee shoe Dual CH 1GS pHnee ey ae CH ar Dual CH 1 25GS Dual CH 1
13. To run the test read the following steps 1 Press Utility button then H1 button turn the M knob to choose Pass fail menu option Pass Fail menu will be displayed in the bottom 2 Enable switch on Press H2 button to show Operate menu then press F1 button to set Enable as ON 3 Create rule Press H4 button to enter Rule setting menu Press F1 button to choose the source Press F2 button turn the M knob to set Horizontal tolerance Press F3 button turn the M knob to set Vertical tolerance Press F4 button to create the rule 4 Set output type Press H3 button to enter Output option setting Choose any one or two of the options Pass Fail or Beep Pass and Fail are mutually exclusive options which could not be chosen simultaneously Stop means stop once the condition satisfies your setting 5 Begin to test Press H2 button then F2 button to select Start the test will begin 6 Save rule Press H5 button then F2 button to save the rules which could be called up at once when need press F3 button to call up the rule saved 59 5 Advanced User Guidebook 1 300ms 1MS s M 5 0ms _ 400mv Depth 100K pass fail Figure 5 47 Pass Fail test Note 1 When Pass Fail is ON if XY or FFT is ready to run then Pass Fail will be closed under the mode of XY or FFT Pass Fail 1s unable 2 Under the mode of Factory Auto Scale and Auto Set Pass Fail will be closed 3 When no save setting left in the rule save
14. and serial number showing Display Press the Utility button and turn the M knob to select the Display to go to the following menu Figure 5 43 Display Menu The description of Display Menu is shown as the follows Setting BackLight O 100 Turn the M knob to adjust the backlight GA ON Turn on or off the battery display 5s 50s OFF Set the disappear time of menu e Adjust Press the Utility button and turn the M knob to select the Adjust to go to the following menu Figure 5 44 Adjust Menu 57 5 Advanced User Guidebook The description of Adjust Menu is shown as the follows Setting Self Cal ee Carry out the self calibration procedure Default Call out the factory settings Do Self Cal Self Calibration The self calibration procedure can improve the accuracy of the oscilloscope under the ambient temperature to the greatest extent If the change of the ambient temperature is up to or exceeds 5C the self calibration procedure should be executed to obtain the highest level of accuracy Before executing the self calibration procedure disconnect the probe or wire and the input connector Press the Utility button Then press the H1 button and the function menu will display at the left of the screen turn the M knob to choose Adjust and then press the H2 button to choose Self Cal entering the self calibration procedure of the instrument Autocalibration Remove all probes cables
15. compensation deviation will result in the measuring error or mistake For adjusting the probe compensation please carry out the following steps 1 Set the attenuation coefficient of the probe in the menu as 10X and that of the switch in the probe as 10X see How to Set the Probe Attenuation Coefficient on P14 and connect the probe with the CH1 channel If a probe hook tip is used ensure that it keeps in close touch with the probe Connect the probe tip with the signal connector of the probe compensator and connect the reference wire clamp with the ground wire connector of the probe connector and then press the button Autoset 2 Check the displayed waveforms and regulate the probe till a correct compensation is achieved see Figure 4 8 and Figure 4 9 13 4 Junior User Guidebook Overcompensated Compensated correctly Under compensated Figure 4 8 Displayed Waveforms of the Probe Compensation 3 Repeat the steps mentioned if needed ia Figure 4 9 Adjust Probe How to Set the Probe Attenuation Coefficient The probe has several attenuation coefficients which will influence the vertical scale factor of the oscilloscope To change or check the probe attenuation coefficient in the menu of oscilloscope 1 Press the function menu button of the used channels CH1 MENU or CH2 MENU 2 Press H3 button to display the Probe menu select the proper value corresponding to the probe This setting will be valid all the
16. not allowed to exceed the permissible value given in technical specification Replacing the Lithium Battery Unit It is usually not required to replace the battery unit But when it is required to replace it only qualified personnel can carry out this operation and only use the same specification lithium battery 95
17. of X Y Function ccccccccsssssssssssscsscccccccssssscsscccsssccssssssssscccssseeees 84 Example 6 Video Signal Trigger i ssctceccvscevevcssecinccsscecvexscesevaceutavecysdecewscacesecssvessvereceesesserseveries 86 OL OU DL NOON Orear i ETETEA EE TET AE OTOS 87 9 Technical Specificati ns rio ERR As 88 General Technical SpecdficationiS sisnisecissorciciiisoiincore cieco ridetan ERE AE ae 93 LOAPPENAIN saa EE 94 ADPENAdI A ENCOSTO ui E EE E E 94 Appendix B General Care and Cleaniing ccccccccsssssssssssssscccccccsssssssccccsscccccsssssssccessseeees 94 Appendix C Battery Usine GUIE sci RS 95 ll 1 General Safety Requirements 1 General Safety Requirements Before any operations please read the following safety precautions to avoid any possible bodily injury and prevent this product or any other products connected from damage In order to avoid any contingent danger this product is only used within the range specified Only the qualified technicians can implement the maintenance To avoid Fire or Personal Injury Connect the probe correctly The grounding end of the probe corresponds to the grounding phase Please don t connect the grounding end to the positive phase Use Proper Power Cord Use only the power cord supplied with the product and certified to use in your country Connect or Disconnect Correctly When the probe or test lead is connected to a voltage source please do not connect and disconnect t
18. should be different Here we set it to 192 168 1 72 The range of the port value is 0 4000 but the port which under 2000 is always be used so it is Suggested to set it to the value above 2000 Here we set it to 3000 75 6 Communication with PC at Ports settings Connect using di E a Gis pore God _ Custom USB Transfer Instructions Some Types can choose to get bin bmp or deep memory data C faveF orm Image High Memory Depth Get Image File bmp Setting Keep Getting Delay ims 2000 Save data file automatically to below directory For there is a limit mmber of files in one single directory of Windows File System FATI6 FATS HTFS the mmber of files to be saved 15 not certain it is recommended to choose a directory in NTFS disk drive turn off the storage channels in device and use short directory path to save more files Get Data now Keep Getting now Figure 6 3 Set the network parameters of the OWON Oscilloscope Software 4 Set the network parameters of the oscilloscope In the oscilloscope press the Utility button and press H1 button turn the M knob to select the LAN Set press the H2 button the set menu is displayed on the right Set the IP and the Port to the same value as the Ports settings in the software in step 3 Press the H3 button to select Save set it prompts reset to update the config After resetting the oscilloscope if you can get data normally in the
19. the SDS series digital storage oscilloscope is no exception This chapter makes a simple description of the operation and function of the front panel of the SDS series oscilloscope enabling you to be familiar with the use of the SDS series oscilloscope in the shortest time Front Panel The SDS series oscilloscope offers a simple front panel with distinct functions to users for their completing some basic operations in which the knobs and function pushbuttons are included The knobs have the functions similar to other oscilloscopes The 5 buttons F1 F5 in the column on the right side of the display screen or in the row under the display screen H1 H5 are menu selection buttons through which you can set the different options for the current menu The other pushbuttons are function buttons through which you can enter different function menus or obtain a specific function application directly Figure 4 1 Front panel 1 Power on off Display area 3 Power indication light Green light Indicating DSO connects with AC Power and the battery is in full Gf there is battery inside DSO Yellow light Indicating DSO connect with AC Power and the battery is in charging if there is battery inside DSO 4 Junior User Guidebook Light off Only powered by battery without connecting AC Power 4 Control key and knob area 5 Probe Compensation Measurement signal 5V 1KHz output The signal parameters could be adjusted in SDS7072 V
20. to the following Steps 1 2 3 4 5 6 7 8 9 Press the Trigger Menu button to display the trigger menu Press the H1 button to display the trigger type menu Press the F1 button to choose Single for Type Turn the M knob to choose Video as the mode Press the H2 button to display the Source menu Press the F1 button to choose CH1 for Source Press the H3 button to display the Modu menu Press the F1 button to choose NTSC for the modulation Press the H4 button to display the sync menu 10 Press the F2 button to choose Field for Sync 11 Turn the VOLTS DIV VERTICAL POSITION and SEC DIV knobs to obtain a proper waveform display see Figure 7 7 0 000ns 125M57s M 50us Depth 100K f Figure 7 7 Waveform Captured from Video Field Trigger 86 8 Troubleshooting 8 Troubleshooting 1 Oscilloscope is powered on but no Display Check whether the power connection is connected properly Check whether the power switch is pushed down to the designated position Check whether the fuse which is beside the AC power input jack 1s blew the cover can be pried open with a straight screwdriver Restart the instrument after completing the checks above If the problem persists please contact Lilliput and we will be under your service 2 After acquiring the signal the waveform of the signal is not displayed in the screen Check whether the probe is properly connected to the signal connecti
21. 111101_ 6545275 Delete the last character z is End and store Esc Enter Switch between Close the keyboard capital and small Figure 5 38 Edit the File Name How to Record Playback Waveforms Wave Record function can record the input current wave You can set the interval between recorded frames in the range of 1ms 1000s The max frame number reaches 1000 and you can get better analysis effect with playback and storage function Wave Record contains four modes OFF Record Playback and Storage Record To record wave according to the interval until it reaches the end frame set Record menu shows as follows OFF Close wave record function Record Set record menu Playback Set playback menu Storage Set storage menu End frame Turn the M knob to select the number of frames to Record mode record 1 1000 FrameSet Interval Turn the M knob to select the interval between recorded frames 1ms 1000s Mode Reiresh ON Refresh Wave during recording OFF Stop refreshing Operate Play Begin to neers Stop Stop recording Note Both of the waveforms of Channel 1 and Channel 2 will be recorded If a Channel is turned off while recording the waveform of the channel is invalid in the playback mode 53 5 Advanced User Guidebook 0 000ns 2505578 M 200us 0 00mv Depth 1K f f f f Stop Figure 5 39 Wave Record Playback Play back the wave recorded or saved Playback menu shows as follows St
22. A hele te a tiaecalas 65 HOw to Usc A UO SCAN aa pants sitet a eagle stead O eh iedasieoss 70 FLOW tO Wise Builki Fle ass aseassnsanecentuessarwecanceaseepamnsconnescssensbenmedaoanaiqasennexteqsuaatannt ersoaceeceeenwmanueoravnacseen 72 How toUs Erec ye BUNOS mo aoe tate anenctuerren canon Maan out itunes tues na oases tev uu Oe sanenetemans 72 6 Communication with PO siccrscvsrecncensnanauceteacsnvnsnassinebencadensnanseseteseansnsnasdgnnbescadensnansetehesosas 74 Usine USB Port i csstecc AicssesccscssicdesassccianscaaccdadewecsSubsuasenievecesavevasesnacsaccsidesecascosedesunssasaaasevaceanseucetes 74 Usine LAN POr enron naa AA 75 COn er ree IN oinera A E O seeteeniane 75 Connect through a Outer ccccccsecsescsecseecsecsucssecsucsuecsecsuccsecsusssessucsuecsucsucssecsucsuecsuessessussuessessucssessnesueeaseeses 76 Usine COM POr oci E T cuesesaecsccvacuselusuessedeceaayesdocscaendede 78 Ts ADOTIVONS TONON osi A ERE EEEE E E T areuieseesintesoseaaast 79 Example 1 Measurement a Simple Signal ssssscecccccssssccecccccosssesceecocsssssececcosssssssceceosssssssee 79 Example 2 Gain of a Amplifier in a Metering Circuit ssssssscceececcccccccoccocssssssseseeceeecessssso 80 Example 3 Capturing a Sinele Signal sic23eicss sce essccacssvnscecencicesevscucseeencacacexeresecacsevecsesssesncsensesave 81 Example 4 Analyze the Details of a Signal ccccccccsssssssssssscccccssssssssssccccsccesssssssscccsssseenss 83 Example 5 Application
23. Accuracy typical EXT 5 200mV 6 of Set Value Tri According to Record length and time base displacement Trigger Holdoff 100ns 10s range 50 level setting Input signal frequency gt 50Hz typical Rising Falling Edge t Sensitivity Positive pulse gt lt Trigger condition 5E negative pulse gt lt Pulse Width range 30ns 10s Mo Modulation Modulation uppon standard NTSC PAL and SECAM broadcast systems Video Trigger 1 525 NTSC and 1 625 PAL SECAM Positive pulse gt lt Pulse trigger Trigger condition Se negative pulse gt lt 24ns 10s Trigger on CH1 Edge Pulse Video Slope Alt te T ARRE Trigger on CH2 Edge Pulse Video Slope Slope Trigger 92 9 Technical Specifications General Technical Specifications Display Display Type 8 Colored LCD Liquid Crystal Display Display Resolution 800 Horizontal x 600 Vertical Pixels Display Colors 65536 colors TFT screen Output of the Probe Compensator Output Volt eee eee About 5V with the Peak to Peak voltage 1MQ Typical Frequency Typical Square wave of 1KHz Power Mains Voltage 100 240 VAC RMS 50 60Hz CAT H lt 18 W SDS6062 V SDS7072 V lt 24W other models 2A T grade 250V Cn 1 Cell 558792 4000mAh 3 7V tt opuona AR Pack 2s2p 7 4V 8000mAh Environment Power Consumption Working temperature 0 C 40 C Storage temperature 20 C 60 C Relative Humidity Temp
24. M SOOMS s 1 6GS s ne lt 800MS s_ 10M 1 6GS s 3 2GS s ee Single CH Dual CH Single CH Interval AT 1 interval time 100ppmxreading 0 6ns accuracy Average gt 16 DC 100MHz 1 interval time 100ppmxreading 0 4ns 8 bits resolution 2 Channels simultaneously Vertical system SDS6062 V 10 div Displacement eee SDS7102 V W 1V 2mV 100mV SDS8102 V 90 9 Technical Specifications Performance Characteristics Instruction SDS a 10V 200mV 1V Sosea Analog bandwidth bandwidth 1OOMHz 200MHz 300MHz Single bandwidth Full bandwidth ee DC accuracy 3 DC accuracy Average gt 16 3 rdg 0 05 div for ax average Waveform inverted ON OFF ETE Vpp Vmax Vmin Vtop Vbase Vamp Vavg Vrms Overshoot Preshoot Freq Period Rise Automatic Time Fall Time Delay A B Delay A B t Width Width Duty Duty Measurement Waveform Math Te fe Full bandwidth idth Phase Lissajous figure differe 3 degrees nce Frequency typical 1KHz square wave 91 9 Technical Specifications Performance Characteristics Instruction USB2 0 USB for file storage LAN port Communication i VGA interface only for the model with V or the models including VGA por interface as default or RS 232 Optional Trigger 6 div from the screen center Trigger level range 600mV Trigger level ext kaonv 6 of Set Vat
25. N knob to change the vertical display position of channel and press the position knob to set the vertical display position back to 0 as a shortcut key this is especially helpful when the trace position is far out of the screen and want it to get back to the screen center immediately 2 Change the Vertical Setting and Observe the Consequent State Information Change With the information displayed in the status bar at the bottom of the waveform window you can determine any changes in the channel vertical scale factor 16 4 Junior User Guidebook Turn the vertical VOLTS DIV knob and change the Vertical Scale Factor Voltage Division it can be found that the scale factor of the channel corresponding to the status bar has been changed accordingly Press buttons of CH1 MENU CH2 MENU and Math the operation menu symbols waveforms and scale factor status information of the corresponding channel will be displayed in the screen Introduction to the Horizontal System Shown as Figure 4 13 there are a button and two knobs in the HORIZONTAL CONTROLS The following practices will gradually direct you to be familiar with the setting of horizontal time base Figure 4 13 Horizontal Control Zone 1 Use the horizontal SEC DIV knob to change the horizontal time base setting and observe the consequent status information change Rotate the horizontal SEC DIV knob to change the horizontal time base and it can be found that t
26. OWON SDS Series Smart Digital Storage Oscilloscopes User Manual E SDS6062 V E SDS7072 V E SDS7102 V E SDS8102 V E SDS8202 V E SDS8302 E SDS9302 Note V for VGA interface optional SDS8302 and SDS9302 including VGA interface as default WWW OWON COM HK May 2013 edition V1 6 3 Copy Right in this Manual Lilliput Company All rights Reserved The Lilliput s products are under the protection of the patent rights in America and other countries including ones which have already obtained the patent rights and those which are applying for The information in this manual will replace all that in the materials published originally The information in this manual was correct at the time of printing However OWON will continue to improve products and reserves the rights to changes specification at any time without notice OWON is the registered trademark of the Lilliput Company Headquarter Fujian Lilliput Optoelectronics Technology Co Ltd The mansion of optoelectronics 19 Heming Road Lantian industrial zone Zhangzhou Fujian China Tel 86 596 2 130430 Fax 86 596 2109272 Web www owon com hk Mail Business Consulting info owon com hk Sale service service owon com hk Branch Xiamen Lilliput Technology Co Ltd the 5th floor B Area Chuangxin Mansion Software Park ZhenZhuWan Huandao RD Xiamen Fujian China Tel 86 592 2575666 Fax 86 592 2575669 General Warranty Lilliput warrants tha
27. Re eee one ase e EL TEES Sie PET SUID Tat CL OMnESRUT Ten On WAIT SONG Te reNe ET Tenn T WIT eRYT Paver aS terePOeeTU na et em 8 Control ke ya kKNOBIATC Iaea E S E T E A AT 9 User Interface Introduci n sscecccessetevageccecacecdateieckd paxecaicsacess A r N ANE SESER 10 How to Implement the General Inspection ssssssseecccccsssscceecceccssssscceccossssscceocossssessseceosssssssee 12 How to Implement the Function Inspection sssscecccccossscceecccocssssscceccossssecccocossssesssececsssssssee 12 How to Implement the Probe Compensation sssseeeecocssssseeecccsscsssscecocossssscccocossssesececeosssssssee 13 How to Set the Probe Attenuation Coefficient ccccccsssssssssscsccccsssssssscssccccssscsssssssssccooees 14 How to Use the Probe Sate y iiviiccccccicacevsxstcswwcviesvesascasdccveceosecacdeis vasdoscvsssceeutscacesdearecdavassdessvdueece 15 How to Implement Self calibration ccccccsssssssscsssccccccccsssscccssssssssssssssssssssccccccsssseees 15 Introduction to the Vertical Systeim ccccccccsssssssssssccccssssssssscsscccsscssssssssssscccssessssssssscooees 16 Introduction to the Horizontal System ccccccsssssssssssccccccccssscccssssssssssssssssssssssccccssssssees 17 Introduction to the Trigger System vsssiecscscscecsccecsdisiceccedecededdsdsaadsccavtscceccsakscauvecdeecestieddcsssadeceus 18 5 Advanced User Guidebook ooo ssosssosseeeeeeeeeooosssssssssssseeeeeceeeeccosossssssssseseee
28. Set Menu The description of the Display Set Menu is shown as follows Setting Dots Only the sampling points are displayed Type Vect The space between the adjacent sampling points in the display is filled with the vector form OFF 1 second Time 2 seconds Turn the M knob to set the persistence time Persist 5 seconds Infinity Clear the persistence XY Mode ON Turn on the XY pay neon OFF Turn off the XY display function AE ON Turn on the cymometer y OFF Turn off the cymometer VA Dp oN e YOA pore et the model with V OFF Ka i pay computer monitor 46 5 Advanced User Guidebook Display Type With the F1 menu selection button pushed down you can shift between Vect and Dots types The differences between the two display types can be observed through the comparison between Figure 5 32 and Figure 5 33 et a SO Oe POC POP OSC DED Oe FT De RO OOD Oe Wei a ie Pee I TO EO De er ORO SOU E teal 12 5M5 s M 500us Depth 100K Type ee A Lect Persist XY Mode iene VGA Disp ORE ON OFF a OFFI ON FE Figure 5 32 Display in the Vector Form WON Coe A A A A Re T E Ra E E oe ON A eee UR ee A Re US ee Sm em NS Rene T E E A E E Nh Re E eS a i Bee a un VGA Dis P cing E il aes fia Door s veet OFF ON OFF ON OFF Figure 5 33 Display in Dots form Persist When the Persist function is used the persistence display effect of the picture tube oscilloscope can be s
29. Signal Noise is very common inside most of the electronic signal To find out what s inside the noise and reduce the level of noise 1s very important function our oscilloscope is capable to offer Noise Analysis The level of noise sometime indicates a failure of electronic circuit The Peak Detect functions acts an important role to help you to find out the details of these noise Here is how we do it 1 Press the Acquire button to display the Acquire menu 2 Press the H1 button to display ACQU Mode menu 3 Press the F2 button to choose Peak detect The signal displayed on the screen containing some noise by turning on Peak Detect function and changing time base to slow down the incoming signal any peaks or burr would be detected by the function see Figure 7 4 0 000ns 12 5M57s M 500us f 0 00mv Depth 100K f Figure 7 4 Signal with Noises Separate Noises from the Signal When focusing on signal itself the important thing is to reduce the noise level as lower as possible this would enable user to have more details about the signal The Average function offered by our Oscilloscope can help you to achieve this Here are the steps for how to enable Average function 1 Press the Acquire button to display the Acquire menu 83 7 Demonstration 2 Press the H1 button to display ACQU Mode menu 3 Press the F3 button turn the M knob and observe the waveform obtained from averaging the waveforms of different aver
30. The analytic resolution of this control knob changes with the vertical division 2 The VOLTS DIV knob is used to regulate the vertical resolution of the wave forms including the captured waveforms and calculated waveforms The sensitivity of the vertical division steps as 1 2 5 Turning clockwise to increase vertical sensitivity and anti clockwise to decrease 3 When the vertical position of the channel waveform is adjusted the changed value is displayed at the left bottom corner of the screen see Figure 5 14 O0 000ns ae a a oe SS 12 5MS s M 500us Depth 100K Figure 5 14 Information about Vertical Position 32 5 Advanced User Guidebook How to Set the Horizontal System The HORIZONTAL CONTROLS includes the HORIZ MENU button and such knobs as HORIZONTAL POSITION and SEC DIV 1 HORIZONTAL POSITION knob this knob is used to adjust the horizontal positions of all channels include those obtained from the mathematical manipulation the analytic resolution of which changes with the time base 2 SEC DIV knob it is used to set the horizontal scale factor for setting the main time base or the window HORIZ MENU button with this button pushed down the screen shows the operating menu see Figure 5 15 oS Figure 5 15 Time Base Mode Menu The description of the Horizontal Menu is as follows Description NVidia ia dime Base The setting of the horizontal main time base is used to display the waveform A w
31. The four trigger modes in Single Trigger are described respectively as follows 1 Edge Trigger An edge trigger occurs on trigger threshold value of input signal Select Edge trigger mode to trigger on rising edge or falling edge 36 5 Advanced User Guidebook The Edge Trigger Menu is shown as Figure 5 19 Figure 5 19 Edge trigger menu Edge menu list Settings Single Mode Set vertical channel trigger type as edge trigger Channel 1 as trigger signal Channel 2 as trigger signal Source External trigger as trigger signal 1 5 of the external trigger signal as trigger signal AC power line as trigger signal Block the direct current component Allow all component pass Coue Block the high frequency signal only low frequency component pass Block the low frequency signal only high frequency component pass Slope Trigger on rising edge Trigger on falling edge Acquire waveform even no trigger occurs Mode Normal Acquire waveform when trigger occurs Single When trigger occurs acquire one waveform then stop Holdoff 100ns 10s turn the M knob to set time interval before Holdoff another trigger occur Reset Set Holdoff time as default value 100ns 2 Video Trigger Choose video trigger to trigger on fields or lines of NTSC PAL or SECAM standard video signals Trig menu refer to Figure 5 20 37 5 Advanced User Guidebook Figure 5 20 Video trigger menu Video menu list MENU SETTING INSTRUCTION Single M
32. age number User would see a much reduced random noise level and make it easy to see more details of the signal itself After applying Average user can easily identify the burrs on the rising and falling edges of some part of the signal see Figure 7 5 0 000ns 12 5M57s M 500us Depth 100K Figure 7 5 Reduce Noise level by using Average function Example 5 Application of X Y Function Examine the Phase Difference between Signals of two Channels Example Test the phase change of the signal after it passes through a circuit network X Y mode is a very useful when examining the Phase shift of two related signals This example takes you step by step to check out the phase change of the signal after it passes a specified circuit Input signal to the circuit and output signal from circuit are used as source signals For the examination of the input and output of the circuit in the form of X Y coordinate graph please operate according to the following steps 1 Set the probe menu attenuation coefficient for 10X and that of the switch in the probe for 10X see How to Set the Probe Attenuation Coefficient on P14 2 Connect the probe of channel to the input of the network and that of Channel 2 to the output of the network 3 Push down the Autoset button with the oscilloscope turning on the signals of the two channels and displaying them in the screen 84 7 Demonstration 4 Turn the VOLTS DIV knob making the amplitu
33. ails Do not operate in wet conditions Do not operate in an explosive atmosphere Keep product surfaces clean and dry 2 Satety Terms and Symbols 2 Safety Terms and Symbols Safety Terms Terms in this manual The following terms may appear in this manual LN Warning Warning indicates the conditions or practices that could result in injury or loss of life A Caution Caution indicates the conditions or practices that could result in damage to this product or other property Terms on the product The following terms may appear on this product Danger It indicates an injury or hazard may immediately happen Warning It indicates an injury or hazard may be accessible potentially Caution It indicates a potential damage to the instrument or other property might occur Safety Symbols Symbols on the product The following symbol may appear on the product AA Hazardous Voltage Protective Earth Terminal rh Chassis Ground Refer to Manual Test Ground To avoid body damage and prevent product and connected equipment damage carefully read the following safety information before using the test tool This product can only be used in the specified applications A Warning The two channels of the oscilloscope are non isolated electrically The channels should adopt common basis during measuring To prevent short circuits the 2 probe ground must not be connected to 2 different non isolated DC level 2 Safety Te
34. am Files Weeillescopelexaspler D0S610051417 bin dtematicalle check LEB a s Figure 6 1 Connect with PC through USB port 74 6 Communication with PC Using LAN Port Connect directly 1 Connection Plug in the LAN line to the LAN port in the right side panel of the oscilloscope plug the other end into the LAN interface of the computer 2 Set the network parameters of the computer Since the oscilloscope can not support obtaining an IP address automatically you should assign a static IP address Here we set the IP address to 192 168 1 71 Internet Protocol TCP IP Properties cows General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate F settings Obtain an IF address automatically IP address Subnet mask 255 255 Default gateway 192 168 y Use the following DNS server addresses Prefered DNS server 192 168 1 Attemate DNS server Advanced Figure 6 2 Set the network parameters of the computer 3 Set the network parameters of the OWON Oscilloscope Software Run the software on the computer choose the Ports settings of the Communications menu item Set Connect using to LAN About the IP the first three bytes is same as the IP in the step 2 the last byte
35. are nearly equal Equal amplitude sine waves with frequencies those are very close Broadband random noise with a relatively slow varying spectrum Better solution for magnitude than Rectangle and good for frequency as well It has slightly better frequency resolution than Hanning Recommend to use for Hamming gt Sine periodic and narrow band random noise Transients or bursts where the signal levels before and after the event are significantly different Good for magnitude but poorer frequency resolution than Hamming Recommend to use for Hanning Sine periodic and narrow band random noise SN Transients or bursts where the signal levels before and after the event are significantly different Best solution for magnitude worst for frequency Recommend to use for i Blackman Single frequency waveforms to find higher F order harmonics Figure 5 10 Figure 5 11 Figure 5 12 Figure 5 13 are examples for measuring sine wave with a frequency of 1kHz under the selection of four different windows for FFT 29 5 Advanced User Guidebook WON 0 000Hz i Source CH1 CH2 Window Rectangle Format Vrms dB 1 00002KHz _ 800mv 0 00div Hira owen FFT Math Figure 5 10 Rectangle window WON 0 000Hz a 1 00001KHz _f 800mv a ka Dual Wfm FFT Math Figure 5 11 Hamming window 30 5 Advanced User Guidebook Won fo o000Hz i V
36. art frame Turn the M knob to select the number of start frame to playback 1 1000 End frame Turn the M knob to select the number of end frame Playback Mode to playback 1 1000 FrameSet Cur frame Turn the M knob to select the number of current frame to playback 1 1000 Interval Turn the M knob to select the interval between played back frames 1ms 1000s Loop Play back the wave continuously Pl Play back the wave just one time Stop Stop recording 54 5 Advanced User Guidebook Playmode Startframe End frame 50 Cur frame Interval 100ms 2505578 M 200us _f0 00mv u E Type Mode Playmode Operate Frameset Recordi layback Coop OncesPiay stop Figure 5 40 Wave Playback Storage Save the current wave according to the start frame and end frame set Storage menu shows as follows Turn the M knob to select the number of start frame to store 1 1000 Turn the M knob to select the number of end frame to store 1 1000 Save fo Save the waveform record file to the internal memory Load fo Load the waveform record file from the memory Storage Start frame Mode Frame Set End frame Savemode Startframe End frame 250KS s M 200us _f 0 00mv Depth 1K Type Made Frameset save Load Record storage Figure 5 41 Wave Storage 55 5 Advanced User Guidebook To use wave record function do as follows 1 2 3 4 5 6 7 8 9 Press Save button Pr
37. banana plug connectors Do not insert metal objects into connectors 3 General Characteristics 3 General Characteristics Y VV VV VV VV Y Y Vv V V WV Bandwidth 60MHz 300 MHz Sample rate real time SOOMS s 3 2GS s Dual channel 10M points on each channel for the Record length Autoscale function 7cm smart design body 8 inch high definition TFT display 800 x 600 pixels Built in FFT function Pass Fail Function Waveform record and playback VGA interface only for the model with V or the models including VGA interface as default Various triggering function USB communication ports Super capacity lithium battery Optional Built in Chinese and English help system Multiple language support 4 Junior User Guidebook 4 Junior User Guidebook This chapter deals with the following topics mainly Introduction to the structure of the oscilloscope Introduction to the user interface How to implement the general inspection How to implement the function inspection How to make a probe compensation How to set the probe attenuation coefficient How to use the probe safely How to implement an auto calibration Introduction to the vertical system Introduction to the horizontal system Introduction to the trigger system 4 Junior User Guidebook Introduction to the Structure of the Oscilloscope When you get a new type oscilloscope you should get acquainted with its front panel at first and
38. be observed that the trigger level value displayed in the screen changes accordingly PS Turning the TRIG LEVEL knob can change trigger level value and it is also the hotkey to set trigger level back to 0 3 Press the button 50 to set the trigger level as the vertical mid point values of the amplitude of the trigger signal 4 Press the Force button to force a trigger signal which is mainly applied to the Normal and Single trigger modes 18 5 Advanced User Guidebook 5 Advanced User Guidebook Up till now you have already been familiar with the basic operations of the function areas buttons and knobs in the front panel of the oscilloscope Based the introduction of the previous Chapter the user should have an initial knowledge of the determination of the change of the oscilloscope setting through observing the status bar If you have not been familiar with the above mentioned operations and methods yet we advise you to read the section of Chapter 4 Junior User Guidebook This chapter will deal with the following topics mainly How to Set the Vertical System How to Set the Horizontal System How to Set the Trigger System How to Implement the Sampling Setup How to Set the Display System How to Save and Recall Waveform How to Record Playback Waveforms How to Implement the Auxiliary System Function Setting How to Implement the Automatic Measurement How to Implement the Cursor Measurement How to Use Autoscale f
39. call the setting from the selected address When the type is Image the menu shows as following Save the current display screen The file can be only stored in a USB storage so a USB storage must be connected first The file name is editable The file is stored in BMP format Save and Recall the Waveform The SDS series oscilloscope can store 15 waveforms which can be displayed with the current waveform at the same time The stored waveform called out can not be adjusted In order to save the waveform of the CH1 into the address 1 the operation steps should be followed 1 Saving Press the H1 button the Type menu will display at the left of screen turn the M knob to choose Wave for Type 2 Press the H2 button and press F1 button to select CH1 for Source 3 Press the H3 button and press the F1 turn the M knob to select 1 as object address 4 Press the H5 button and press F1 button to select Internal 5 Press the H4 button to save the waveform 6 Recalling Press the H3 button and press the F1 turn the M knob to select 1 as object address Press F2 button to set Show as ON The waveform stored in the address will be shown the address number and relevant information will be displayed at the top left of the screen 5I 5 Advanced User Guidebook 12 5MS s M 500us f 40 0v Depth 100K f f Internal Figure 5 37 Wave Saving Tip Whatever the Type of save menu is set you can save the waveform b
40. ction Inspection Make a fast function check to verify the normal operation of the instrument according to the following steps 1 Connect the power cord to a power source Turn on the Power Switch Button on the left side make sure the side is pressed down Then push down the button of the Or signal on the top The instrument carries out all self check items and shows the Boot Logo Press the Utility button then press H1 button to get access to the Function menu Turn the M knob to select Adjust and press H3 button to select Default The default attenuation coefficient set value of the probe in the menu is 10X 2 Set the Switch in the Oscilloscope Probe as 10X and Connect the Oscilloscope with CH1 Channel Align the slot in the probe with the plug in the CH1 connector BNC and then tighten the probe with rotating it to the right side 12 4 Junior User Guidebook Connect the probe tip and the ground clamp to the connector of the probe compensator 3 Press the Autoset Button The square wave of 1 KHz frequency and 5V peak peak value will be displayed in several seconds see Figure 4 7 12 5MS s M S500us Depth 100K Figure 4 7 Auto set Check CH2 by repeating Step 2 and Step 3 How to Implement the Probe Compensation When connect the probe with any input channel for the first time make this adjustment to match the probe with the input channel The probe which is not compensated or presents a
41. d Mode Normal Acquire waveform when trigger occurred Single When trigger occurs acquire one waveform then stop Holdoff 100ns 10s turn the M knob to set time interval before another trigger occur Reset Set Holdoff time as 100ns 4 Pulse Width Trigger Pulse trigger occurs according to the width of pulse The abnormal signals can be Holdoff detected through setting up the pulse width condition The Pulse Width Trigger Menu is shown as Figure 5 22 Figure 5 22 Pulse Width Trigger menu Pulse Width Trigger menu list aaa U SETTING INSTRUCTION Single Mode Mode Pulse Pulse Set vertical channel trigger type as Set vertical channel trigger type as pulse trigger trigger ee ai anaien a CH1 as the trigger source Source Select CH2 as the trigger source Not allow DC portion to pass ae Allow all portion pass Coupling HF Not allow high frequency of signal pass and only low frequency portion pass LF Not allow low frequency of signal pass and only high frequency portion pass Polarity Choose the polarity Select pulse width condition and adjust the M knob to set time 39 5 Advanced User Guidebook Auto Acquire waveform even no trigger occurred Normal Acquire waveform when trigger occurred Single When trigger occurs acquire one waveform then stop Mode Holdoff 100ns 10s adjust M knob to set time interval before another trigger occur Reset Set Holdoff time as 100ns Holdoff Alternate trigge
42. des of two signals equal in the rough 5 Press the Display button and recall the Display menu 6 Press the H3 button and choose XY Mode as ON The oscilloscope will display the input and terminal characteristics of the network in the Lissajous graph form 7 Turn the VOLTS DIV and VERTICAL POSITION knobs optimizing the waveform 8 With the elliptical oscillogram method adopted observe and calculate the phase difference see Figure 7 6 The signal must be centered and kept in the horizontal direction Figure 7 6 Lissajous Graph Based on the expression sin q A B or C D thereinto q is the phase difference angle and the definitions of A B C and D are shown as the graph above As a result the phase difference angle can be obtained namely q arcsin A B or arcsin C D If the principal axis of the ellipse is in the I and HI quadrants the determined phase difference angel should be in the I and IV quadrants that is in the range of 0 r 2 or 3a 2 2r If the principal axis of the ellipse is in the II and IV quadrants the determined phase difference angle is in the H and III quadrants that is within the range of 1 2 a or a 3m 2 85 7 Demonstration Example 6 Video Signal Trigger Observe the video circuit of a television apply the video trigger and obtain the stable video output signal display Video Field Trigger For the trigger in the video field carry out operations according
43. display at the right of the screen Press the F2 button to set MeasCurr to YES the A V radio menu will appear below Press the F3 button turn the M knob to set the Amps Volts ratio Amps Volts ratio 1 Resistor value Here the A V radio should be set to 1 The Figure 5 5 illustrates the setting and the vertical scale factor when measuring current by probing the voltage drop across a 1Q resistor 23 5 Advanced User Guidebook 0 000ns 00 1MS s M 500us FERIT Depth 10K f f f full band Figure 5 5 Measure Current 4 To invert a waveform Waveform inverted the displayed signal is turned 180 degrees against the phase of the earth potential Taking the Channel 1 for example the operation steps are shown as follows 1 Press the CH1 MENU button to show CH1 SETUP menu 2 Press the H2 menu selection button and select ON for Inverted item The waveform is inverted as it is shown in Figure 5 7 3 Press the H2 menu selection button again and select OFF for Inverted item The waveform goes back to its original one as it is shown in Figure 5 6 24 5 Advanced User Guidebook ee p is _ PEES M 500us 1 36V Depth 10K ae Couplin Inverted Eme 3 Probe a DC ON FF full band Figure 5 6 Original Waveform a 1M57s M 500us Depth 10K E Tae Probe a OFF full band Figure 5 7 Inverted Waveform 5 To set bandwidth limit SDS6062 V SDS7072 V does not have this function When high frequency components o
44. djusted with the VERTICAL POSITION knob of Channel 1 and that of Cursor 2 can be adjusted with the VERTICAL POSITION knob of Channel 2 Perform the following operation steps for the Vamp cursor measurement 1 Press Cursor and recall the Cursor Measure menu 2 Press the H1 button the Type menu will display at the right of the screen Press the F2 button to select Vamp for Type with two purple dotted lines displayed along the horizontal direction of the screen indicating Cursor and Cursor2 3 According to the measured waveform adjust the positions of Cursorl and Cursor2 by turning the VERTICAL POSITION knob of CH1 and CH2 Cursor increment window at the left bottom shows absolute value of the two cursors amplitude difference and the present position 68 5 Advanced User Guidebook 0 000Hz 1 00001KHz GEZ 250Hz J 50 0mv 0 00div Vamp IMathF FT Figure 5 59 wave of Vamp cursor measurement Carry out the following operation steps for the Freq cursor measurement l 2 Press Cursor and recall the Cursor Measure menu Press the H1 button the Type menu will display at the right of the screen Press the F3 button to select Freq for Type with two purple dotted lines displayed along the vertical direction of the screen indicating the corresponding Cursor 1 and Cursor 2 According to the measured waveform adjust the positions of Cursorl and Cursor2 by turning the VERTICAL POSITION knob of CH1 and CH2 Increment w
45. e Display Set Menu 2 Press the H3 menu selection button to set XY Mode ON The display format is changed to be XY mode see Figure 5 35 SOKS s M 1 0Oms Depth 1K Persist OFF Figure 5 35 XY Display Mode Cymometer It is a 6 digit cymometer The cymometer can measure frequencies from 2Hz to the full bandwidth Only if the measured channel has triggering signal and in Edge mode it can measure frequency correctly In the Single trigger mode it is a one channel cymometer and it can only measure the frequency of the triggering channel In the ALT trigger mode it is a two channel cymometer and it can measure the frequency of two channels The cymometer is displayed at the right bottom of the screen To turn the cymometer on or off 1 Press the Display button 2 In the Display menu press the H4 button to toggle between the cymometer display ON or OFF VGA Output only for the model with V The VGA port could be connected to a computer monitor The image of the oscilloscope can be clearly displayed on the monitor To set the VGA Output 1 Press the Display button 2 Inthe Display menu press the H5 button to toggle between ON or OFF 49 5 Advanced User Guidebook How to Save and Recall a Waveform Press the Save button you can save the waveforms settings or screen images The menu displayed in the screen is shown as Figure 5 36 Internal Figure 5 36 Waveform Save Menu The description of the Save Fu
46. eady Pre triggered data captured and ready for a trigger Scan Capture and display the waveform continuously Stop Data acquisition stopped The purple T pointer indicates the horizontal position for the trigger The pointer indicates the trigger position in the internal memory The two yellow dotted lines indicate the size of the viewing expanded window It shows present triggering value and displays the site of present window in internal memory It shows setting time see Config on P56 It indicates that there is a U disk connecting with the oscilloscope Indicating battery power status see Display on P57 10 The red pointer shows the trigger level position for CH1 10 11 12 13 14 15 16 17 4 Junior User Guidebook The waveform of CH1 The positions of two purple dotted line cursors measurements The yellow pointer shows the trigger level position for CH2 The waveform of CH2 The frequency of the trigger signal of CH1 The frequency of the trigger signal of CH2 It indicates the current function menu 18 19 Current trigger type 20 ZA Ze 25 24 2D 26 2l Rising edge triggering L Falling edge triggering ae Video line synchronous triggering 2 Video field synchronous triggering The reading shows the trigger level value of the corresponding channel The reading shows the window time base value The reading shows the setting of main time base The readings show cu
47. eeeceeccsssssssssssee 19 Howto Set the Vertical Systemie niena a aa a EaR ERa Rea 20 Use Mathematical Manipulation Function eeeeeesessssssseeeeeeeresssssssssssseserreeresssssssssssseeeeeeeessssssssssssee 26 USOS FFEN ne nena a a R 28 Use VERTICAL POSITION and VOLTS DIV Knob sssscssccscccccsssssssssccccsseeenes 32 How to Set the Horizontal SystemM eecccsssesccccccssscscccccecccsssseccecoccsssscecccococsssececccoosssssececesssssese 33 How to Set the Triscer SystenMi iracas eiecti eeina a Ea S EEA A 36 So FS TS E aa E ak cele el tenlet Sata Ste Sanaa hci calli as tule eld oat it cel ata nee 36 POMP ALC CI CT a sat a Sacchi h ease ave Sane ina cea atte dunia lvoe ela ge dec sna ulate ecw seaaaa eas dads baa iatan M Smale Gua eade vias 40 How to Operate the Function Menu ssssssseeeccccsssseccecococossscccccoossssscecocossssesscecoccsssssseeeosssssssee 44 Flow 10 Implement o amphi Seips a E a 44 How tO SEC ING DEDA SyS E Ma tea insudeatnndes Reeaseasunueadat tepseuadantendesMivaseasmaneduetusantis 46 How to Save and Recall a Waveloriy ci5schatenissscascacanete cintiaeads heen aadagn chee cia eer eas aaa 50 How to Record Play back Way CLorins soniai Sencar Misc atensuaailo nara aaa aan a 53 How to Implement the Auxiliary System Function Setting cccssssssssssseeeeeeeeeeceeeeeaaeeesseseeeseeeeeess 56 How to Measure Automatically rsisi E EAT E T E A E 62 Howto Measure With CUrsOrs aae einean NAAA NEA E
48. ent settings in the operating menu of the Channel should always match what is on the probe see How to Set the Probe Attenuation Coefficient on P14 If the attenuation coefficient of the probe is 1 1 the menu setting of the input channel should be set to X1 Take the Channel 1 as an example the attenuation coefficient of the probe is 10 1 the operation steps are shown as follows ZZ 5 Advanced User Guidebook 1 Press the CH1 MENU button to show CH1 SETUP menu 2 Press the H3 menu selection the Probe menu will display at the right of the screen Press the F1 button to select Attenu In the menu at the left of the screen turn the M knob to select X10 for the probe The Figure 5 4 illustrates the setting and the vertical scale factor when the probe of the attenuation coefficient of 10 1 is used 0 000ns 1MS s M 500us _ 3 40V Depth 10K H f full band Figure 5 4 Regulation of the Attenuation Ratio of the Probe A list of the probe attenuation coefficient and the corresponding menu settings Attenuation Coefficient of the Probe Corresponding Menu Setting 100 1 X100 1000 1 X 1000 3 To measure current by probing the voltage drop across a resistor Take the Channel as an example if you are measuring current by probing the voltage drop across a 1Q resistor the operation steps are shown as follows 1 Press the CH1 MENU button to show CH1 SETUP menu 2 Press the H3 menu selection the Probe menu will
49. enu l accurate reading of vertical scale If you are measuring current by probing the voltage MeasCurr l drop across a resistor choose YES Turn the M knob to set the Amps Volts ratio The A V mA V range is 100mA V 1KA V V A mV A Amps Volts ratio 1 Resistor value Volts Amp ratio is automatically calculated Limit full band Get full bandwidth SDS6062 V 20M Limit the channel bandwidth to 20MHz to reduce SDS7072 V display noise does not have this function 1 To set channel coupling Taking the Channel 1 for example the measured signal is a square wave signal containing the direct current bias The operation steps are shown as below 1 Press the CH1 MENU button to show CH1 SETUP menu 2 Press the H1 button the Coupling menu will display at the screen 3 Press the F1 button to select the Coupling item as DC Both DC and AC components of the signal are passed The waveforms are shown as Figure D2 4 Then press F2 button to select the Coupling item as AC The direct current component of the signal is blocked The waveforms are shown as Figure 5 3 21 5 Advanced User Guidebook f 1 36V uplin Inverted CIME Probe ae oc ow sorr full band Figure 5 2 DC Coupling Oscillogram Bee ake tone er 71 36V Bo AERIS Coupling Inverted Limit Probe B ON OFF full band Figure 5 3 AC Coupling Oscillogram To adjust the probe attenuation For correct measurements the attenuation coeffici
50. er Trigger Mode Pulse Alternate trigger Trigger Type Pulse Menu is shown as Figure 5 26 Figure 5 26 Alternate trigger Trigger Type Pulse Menu Alternate trigger Trigger Type Pulse menu list MENU SETTING INSTRUCTION Alternat ua Pulse Set vertical channel trigger type as pulse trigger ome Select CH1 as the trigger source Source Select CH2 as the trigger source Not allow DC portion to pass Allow all portion pass Coupling Not allow high frequency of signal pass and only low frequency portion pass Not allow low frequency of signal pass and only high frequency portion pass Polarity Choose the polarity Select pulse width condition and turn the M knob to set time Acquire waveform even no trigger occurred Holdoff 100ns 10s adjust M knob to set time interval before another trigger occur Reset Set Holdoff time as 100ns Holdoff Term interpretation 1 Source Trigger can occur from several sources Input channels CH1 CH2 AC Line Ext Ext 5 Input It is the most commonly used trigger source The channel will work when 42 2 5 Advanced User Guidebook selected as a trigger source whatever displayed or not Ext Trig The instrument can be triggered from a third source while acquiring data from CH1 and CH2 For example to trigger from an external clock or with a signal from another part of the test circuit The EXT EXT 5 trigger sources use the external trigger signal connected
51. erature Height Operating 3 000 m Non a _ 15 000 m Cooling Method Natural convection C S lt XY convection Mechanical Specifications 340mmx 155mmx70mm L H W About 1 82 kg Interval Period of Adjustment One year is recommended for the calibration interval period 93 10 Appendix 10 Appendix Appendix A Enclosure Standard Accessories A pair of Passive probe 1 2 m 1 1 10 1 1x CD PC link application software 1x Power cord up to the standards of the country in which it is used 1x USB cable 1x Quick Guide Options Battery Appendix B General Care and Cleaning General Care Do not store or leave the instrument where the liquid crystal display will be exposed to direct sunlight for long periods of time Caution To avoid any damage to the instrument or probe do not exposed it to any sprays liquids or solvents Cleaning Inspect the instrument and probes as often as operating conditions require To clean the instrument exterior perform the following steps 1 Wipe the dust from the instrument and probe surface with a soft cloth Do not make any scuffing on the transparent LCD protection screen when clean the LCD screen 2 Disconnect power before cleaning your Oscilloscope Clean the instrument with a wet soft cloth not dripping water It is recommended to scrub with soft detergent or fresh water To avoid damage to the instrument or probe do not use any
52. ess H1 button turn the M knob to choose Record Press H2 button In the Mode menu press F2 button to choose Record Press H3 button In the Frame Set menu press F1 button and turn the M knob to set End frame press F2 button and turn the M knob to select the interval between recorded frames Press H4 button choose whether to refresh the wave when recording Press H5 button to start recording Press H2 button In the Mode menu press F3 button to enter the Playback mode Set the frame range and Playmode Then press H5 button to play To save the wave recorded press H2 button In the Mode menu press F4 button to choose Storage then set the range of frames to store press H4 button to save To load the waveform from the internal memory press Load and then enter playback mode to analyze the wave How to Implement the Auxiliary System Function Setting e Config Press the Utility button and turn the M knob to select Config to go to the following menu f Figure 5 42 Configuration Menu The description of Configuration Menu is shown as the follows 56 5 Advanced User Guidebook Setting Chi aes Choose the display language of the operating Language English Others Display a On Off the date display Set Time system Setting Hour Minute Day Month Setting Date Month Lock all keys Unlock method press 50 ota button in trigger control area then press Force button repeat 3 times About Version number
53. f a waveform are not important to its analysis the bandwidth limit control can be used to reject frequencies above 20 MHz Taking the Channel for example the operation steps are shown as below 1 Press the CH1 MENU button to show CH1 SETUP menu 2 Press the H4 button and the Limit menu will display 25 5 Advanced User Guidebook 3 Press the F1 button to select the Band Limit as full band The high frequency of the signal will be allowed to pass 4 Press the F2 button to select the Band Limit as 20M The bandwidth is limited to 20MHz The frequencies above 20MHz will be rejected Use Mathematical Manipulation Function The Mathematical Manipulation function is used to show the results of the addition multiplication division and subtraction operations between Channel and Channel 2 and the FFT operation of Channel 1 or Channel 2 Figure 5 8 Wave math menu The corresponding FCL Functional Capabilities List of the Waveform Calculation Function Menu Setting Description H1 Factor 1 oa gt Select the signal source of the factor Select the sign of mathematical manipulation H1 Factor 2 7 gt Select the signal source of the factor2 Dual Wfm Math Turn the M knob to adjust the vertical position of M waveform Turn the M knob to adjust the voltage division of M waveform CH1 Select CH1 as FFT source VERT POS VOLTS DIV YUN p ya FFT Source CH2 Select CH2 as FFT source 26 5 Adva
54. form then stop Single In Single mode after pressing the Run Stop key the oscilloscope waits for trigger While the trigger occurs the oscilloscope acquires one waveform then Stop Coupling Trigger coupling determines what part of the signal passes to the trigger circuit Coupling types include AC DC LF Reject and HF Reject AC AC coupling blocks DC components DC DC coupling passes both AC and DC components LF Reject LF Reject coupling blocks DC component and attenuates all signal with a frequency lower than 8 kHz HF Reject HF Reject coupling attenuates all signals with a frequency higher than 150 kHz 4 Holdoff Trigger holdoff can be used to stabilize a waveform The holdoff time is the oscilloscope s waiting period before starting a new trigger The oscilloscope will not trigger until the holdoff time has expired It provides a chance for user to check the signal in a short period and helps to check some complex signals such as AM wavetorm etc 43 5 Advanced User Guidebook How to Operate the Function Menu The function menu control zone includes 8 function menu buttons Measure Acquire Utility Cursor Autoscale Save Display Help and 4 immediate execution buttons Autoset Run Stop Single Copy How to Implement Sampling Setup Press the Acquire button and the menu is displayed in the screen shown as Figure 5 27 Figure 5 27 ACQU MODE Menu The description of the Acqu Mode Menu i
55. from CH1 CH2 Press lt Auto calibration gt for Calibration Press any key to quit 1MS s M 5 0ms _ 0 00mv Depth 100K f f f Figure 5 45 Self Calibration e Pass Fail The Pass Fail function monitors changes of signals and output pass or fail signals by comparing the input signal that is within the pre defined mask Press the Utility button and turn the M knob to select the Pass fail to go to the following menu pass fail Figure 5 46 Pass Fail menu 58 5 Advanced User Guidebook The description of Pass Fail Menu is shown as the follows Setting onee Enable Control enable switch Operate Control operate switch Signal tested corresponds with the rule Signal tested not correspond with the rule Output Beep when it satisfies the rule Stop once satisfying the rule Control the display status of info frame Source Select source CH1 CH2 or Math Horizontal Change the Horizontal tolerance value by turning the M knob Vertical Change the Vertical tolerance value by turning the M knob Create Use the rule set as testing rule Number Choose any one from Rulel Rule8 as your rule name SaveRule Save Click Save to save the rule Load Load some rule as the testing rule Pass Fail test Detect whether the input signal is within the limits of the rule if 1t exceeds limits of the rule it is Fail otherwise it is Pass Also it can output fail or pass signal by built in and configurable output port
56. he Horizontal Time Base display in the status bar changes accordingly 2 Use the HORIZONTAL POSITION knob to adjust the horizontal position of the signal in the waveform window The HORIZONTAL POSITION knob is used to control the triggering displacement of the signal or for other special applications If it is applied to triggering the displacement it can be observed that the waveform moves horizontally with the knob when you rotate the HORIZONTAL POSITION knob Triggering displacement back to 0 shortcut key Turn the HORIZONTAL POSITION knob to change the horizontal position of channel and press the HORIZONTAL POSITION knob to set the triggering displacement back to 0 as a shortcut key 3 With the HORIZ MENU button you can do the Window Setting and the Window Expansion 17 4 Junior User Guidebook Introduction to the Trigger System As shown in Figure 4 14 there are one knob and three buttons make up TRIGGER CONTROLS The following practices will direct you to be familiar with the setting of the trigger system gradually Figure 4 14 Trigger Control Zone 1 Press the Trigger Menu button and call out the trigger menu With the operations of the menu selection buttons the trigger setting can be changed 2 Use the TRIG LEVEL knob to change the trigger level setting By rotating the TRIG LEVEL knob the trigger indicator in the screen will move up and down With the movement of the trigger indicator it can
57. he probe or test lead at random Product Grounded This instrument is grounded through the power cord grounding conductor To avoid electric shock the grounding conductor must be grounded The product must be grounded properly before any connection with its input or output terminal When powered by AC power it is not allowed to measure AC power source directly because the testing ground and power cord ground conductor are connected together otherwise it will cause short circuit When powered by battery the product must ground connection To avoid electric shock there must be a ground wire connect between ground and the ground port on the back of product panel Check all Terminal Ratings To avoid fire or shock hazard check all ratings and markers of this product Refer to the user s manual for more information about ratings before connecting to the instrument Do not operate without covers Do not operate the instrument with covers or panels removed Use Proper Fuse Use only the specified type and rating fuse for this instrument Avoid exposed circuit Do not touch exposed junctions and components when the instrument is powered Do not operate if in any doubt If you suspect damage occurs to the instrument have it inspected by qualified service personnel before further operations Use your Oscilloscope in a well ventilated area Make sure the instrument installed with proper ventilation refer to the user manual for more det
58. imulated The reserved original data is displayed in fade color and the new data is in bright color Press the H2 button the Persist menu will display at the right of screen Press the F1 button different persistence time can be chosen 47 5 Advanced User Guidebook OFF lsecond 2second 5second and Infinity When the Infinity option is set for Persist time the measuring points will be stored till the controlling value is changed see Figure 5 34 By pressing the F2 button the persistence will be cleared 160 0us 12 5MS s M 500us E 44 Ov Depth 100K f A Figure 5 34 Infinite Persistence Display XY Format This format is only applicable to Channel 1 and Channel 2 After the XY display format is selected Channel 1 is displayed in the horizontal axis and Channel 2 in the vertical axis the oscilloscope is set in the un triggered sample mode the data are displayed as bright spots The operations of all control knobs are as follows E The Vertical VOLTS DIV and the VERTICAL POSITION knobs of Channel 1 are used to set the horizontal scale and position E The Vertical VOLTS DIV and the VERTICAL POSITION knobs of Channel 2 are used to set the vertical scale and position continuously The following functions can not work in the XY Format M Reference or digital wave form Cursor Time base control Trigger control FFT 48 5 Advanced User Guidebook Operation steps 1 Press the Display button and call out th
59. indow area is defined by two cursors This perce vencew function is not available at FFT mode Posi Zoon Windows The defined window area for display is expanded to the full screen Main Time Base Press the H1 menu selection button and choose Main In this case the HORIZONTAL POSITION and SEC DIV knobs are used to adjust the main window The display in the screen is shown as Figure 5 16 33 5 Advanced User Guidebook Figure 5 16 Main Time Base Set Window Press the H2 menu selection button and choose Set The screen will show a window area defined by two cursors Use the HORIZONTAL POSITION and SEC DIV knobs to adjust the horizontal position and size of this window area In FFT mode Set menu is invalid See Figure 5 17 Won 5 0 000ns 1 31 12 5M5 s M 500us W 100us Depth 100K OT 000s o set i Figure 5 17 Window Setting Window Expansion Press the H3 menu selection button and choose Zoom As a result the window area defined by two cursors will be expanded to the full screen size see Figure 5 18 34 5 Advanced User Guidebook 12 5M5 s M 500us wW 100us Depth 100K f Figure 5 18 Zoom Window 35 5 Advanced User Guidebook How to Set the Trigger System Trigger determines when DSO starts to acquire data and display waveform Once trigger is set correctly it can convert the unstable display to meaningful waveform When DSO starts to acquire data it will collect enough data to draw waveform
60. indow shows two cursors difference value and the present position see Figure 5 60 69 5 Advanced User Guidebook 0 000Hz 4x 1 000KHZ x1 5 0Q00HZ z x2 1 005KHZ i z 1 00001KHz SKS s 250Hz _f 800mv 0 00div Figure 5 60 wave of Freq cursor measurement How to Use Autoscale This is a very useful function for first time users to carry out a simple and quick test on the input signal The function is applied to follow up signals automatically even if the signals change at any time Autoscale enables the instrument to set up trigger mode voltage division and time scale automatically according to the type amplitude and frequency of the signals Figure 5 61 Autoscale menu The menu 1s as follows ON Turn on Autoscale Autoscale OFF Turn off Autoscale 70 5 Advanced User Guidebook Follow up and adjust both vertical and horizontal settings Follow up and only adjust horizontal scale Follow up and only adjust vertical scale Show Multi period waveforms Only show one or two periods If you want to measure the two channel signal you can do as the follows 1 Press Autoscale button the function menu will appear 2 Press H1 to choose ON 3 Press H2 and choose for Mode item 4 Press H3 and choose ATATA VAYAS for Wave item Then the wave is displayed in the screen shown as Figure 5 62 0 000ns 12 5M57s M 500us 800mv Depth 100K I Figure 5 62 Autoscale Horizontal Vertica
61. isions till the waveform meets your requirement 2 Perform Automatic Measurement The oscilloscope can measure most of the displayed signals automatically To measure the period and frequency of the Channel 1 and the mean and peak to peak voltage of the Channel 2 follow below steps 1 Press the Measure button to activate the measurement function menu 2 Press the H1 to display the Add menu 3 Press the F2 button to choose CH1 as the source 4 Press the F1 button the type items will display at the left of screen and turn the M knob to choose Period 5 Press the F4 button the period measurement will be added 6 Press the F1 button again the type items will display at the left of screen and turn the M knob to choose Freq 7 Press the F4 button the frequency measurement will be added finish settings of channel 1 8 Press the F2 button to choose CH2 as the source 9 Press the F1 button the type items will display at the left of screen and turn the M knob to choose Mean 10 Press the F4 button the mean measurement will be added 11 Press the F1 button the type items will display at the left of screen and turn the M knob to choose PK PK 12 Press the F4 button the peak to peak voltage measurement will be added finish 79 7 Demonstration settings of channel 2 Then the period frequency mean and peak to peak voltage will be displayed at the bottom left of the screen and change periodically
62. l F5 Menu off turn off the menu M knob Multipurpose knob when a M symbol appears in the menu it indicates you can turn the M knob to select the menu or set the value You can press it to close the menu on the left 5 Function key area Total 12 keys 6 Vertical control area with 3 keys and 4 knobs CH1 MENU and CH2 MENU correspond to setting menu in CH1 and CH2 Math key refer to math menu the math menu consists of six kinds of operations including CH1 CH2 CH2 CH1 CH1 CH2 CH1 CH2 CH1 CH2 and FFT Two VERTICAL POSITION knob control the vertical position of CH1 CH2 and two VOLTS DIV knob control voltage scale of CH1 CH2 Horizontal control area with 1 key and 2 knobs HORIZONTAL POSITION knob control trigger position SEC DIV control time base HORIZ MENU key refer to horizontal system setting menu Trigger control area with 3 keys and 1 knob TRIG LEVEL knob is to adjust trigger voltage Other 3 keys refer to trigger system setting 4 Junior User Guidebook User Interface Introduction oe a 7 8 9 1 2 3 4 5 6 7 O 9 130 0us mPa 9 40y Cursorl1 16 20v Cursor2 6 80v 7 3 C 1 00000KHz 12 5MS s M 500us idiv Depth 100K 23 22 21 20 19 18 Figure 4 6 Illustrative Drawing of Display Interfaces Waveform Display Area The state of trigger including Auto Automatic mode and acquire waveform without triggering Trig Trigger detected and acquire waveform R
63. l multi period waveforms Note 1 Entering into Autoscale function and the symbol A will be flickering on the top left of the screen every 0 5 second 2 In the mode of Autoscale the oscilloscope can self estimate Trigger Type Single and Alternate and Mode Edge Video At this point the trigger menu is not available 3 At the mode of XY and STOP status pressing Autoset to enter into Autoscale DSO switches to YT mode and AUTO triggering 71 5 Advanced User Guidebook 4 At the mode of Autoscale DSO is always set as DC coupling with AUTO triggering In this case making Triggering or Coupling settings have no effect 5 At the mode of Autoscale if adjust the vertical position voltage division trigger level or time scale of CH1 or CH2 the oscilloscope will turn off Autoscale function To back to Autoscale press Autoset 6 Turn off the submenu at the Autoscale menu the Autoscale is off and turn on the submenu still enters into the function 7 When video triggering the horizontal time scale is 5Ous If one channel is showing edge signal the other channel is showing video one the time scale refers to 50us as video one as standard 8 While the Autoscale is working settings below will be made forcibly 1 The DSO will switch from non main time base to main time base status 2 The DSO will switch to Peak detection mode if it is in Average mode How to Use Built in Help Press Help button the catalog will disp
64. lay in the screen Press H1 or H2 to choose help topic or just turn the M knob to choose Press H3 to view the details about the topic or just press the M knob es ee ae Press H5 to exit the help or just do other operations How to Use Executive Buttons Executive Buttons include Autoset Run Stop Single Copy Autoset It s a very useful and quick way to apply a set of pre set functions to the incoming signal and display the best possible viewing waveform of the signal and also works out some measurements for user as well The details of functions applied to the signal when using Autoset are shown as the following table Mid point Setting 12 5 Advanced User Guidebook Run Stop Enable or disable sampling on input signals Notice When there is no sampling at STOP state the vertical division and the horizontal time base of the waveform still can be adjusted within a certain range in other words the signal can be expanded in the horizontal or vertical direction When the horizontal time base is lt 50ms the horizontal time base can be expanded for 4 divisions downwards Single Press this button you can set the trigger mode as single directly so when trigger occurs acquire one waveform then stop Copy You can save the waveform by just pressing the Copy panel button in any user interface The source wave and the storage location are according to the settings of the Save function menu when the Type is Wave For mo
65. nced User Guidebook Rectangle Blackman Window Select window for FFT Hanning Hamming dB Select dB for Format Format Vrms Select Vrms for Format x1 Set multiple X 1 X2 Set multiple X2 Zoom x5 Set multiple X85 X10 Set multiple X10 Taking the additive operation between Channel 1 and Channels 2 for example the operation steps are as follows l 2 Press the Math button to bring up the Wfm Math menu Press the H1 button and call out the Dual Wfm Math menu The menu will display at the left of the screen Press the F1 menu selection button and choose CH1 for Factor Press the F2 menu selection button and choose Press the F3 menu selection button and choose CH2 for Factor2 The green calculated waveform M is displayed in the screen Press the F4 menu selection button and choose VERT POS turn the M knob to adjust the vertical position of M waveform Press the F5 menu selection button and choose VOLTS DIV turn the M knob to adjust the voltage division of M waveform 21 5 Advanced User Guidebook 12 5MS s S M 500us Depth 100K f Figure 5 9 Waveform resulted from CH1 CH2 Using FFT function The FFT fast Fourier transform math function mathematically converts a time domain waveform into its frequency components It is very useful for analyzing the input signal on Oscilloscope You can match these frequencies with known system frequencies such as system clocks oscillators or power supplies
66. nction Menu is shown as the following table Setting Wave Sanne Choose the saving type about the Record type see How to Record Playback Waveforms on P53 T ype Image Record When the type is Wave the menu shows as following CH1 Source CH2 Choose the waveform to be saved Math i is eaa Object 1 15 saved to or recall from Recall or close the waveform stored in the current object address When the show is ON if the current object address has been he eal Show ON used the stored waveform will be shown OFF the address number and relevant information will be displayed at the top left of the screen if the address is empty it will prompt None is saved Save the waveform of the source to the selected address Whatever the Type of save menu is set you can save the Save l l waveform by just pressing the Copy panel button in any user interface Storage format is BIN Save to internal storage or USB storage When External is selected save the waveform according to the current record length see Record Length Menu on P45 the file name is editable The waveform Storage Internal z External file could be open by OWON waveform analysis software on the supplied CD When the type is Setting the menu shows as following 50 5 Advanced User Guidebook Setting 1 Setting suas The setting address Settings S Save the current oscilloscope setting to the ave l internal storage pod Re
67. ng wire Check whether the signal connecting wire is correctly connected to the BNC namely the channel connector Check whether the probe is properly connected with the object to be measured Check whether there is any signal generated from the object to be measured the trouble can be shot by the connection of the channel from which there is a signal generated with the channel in fault Make the signal acquisition operation again 3 The measured voltage amplitude value is 10 times or 1 10 of the actual value Look at the attenuation coefficient for the input channel and the attenuation ration of the probe to make sure they are match see How to Set the Probe Attenuation Coefficient on P14 4 There is a waveform displayed but it is not stable Check whether the Source item in the TRIG MODE menu is in conformity with the signal channel used in the practical application Check on the trigger Type item The common signal chooses the Edge trigger mode for Type and the video signal the Video If Alternate trigger is selected both of the channel 1 and channel 2 trigger levels should be adjusted to the proper position Only if a proper trigger mode is applied the waveform can be displayed steadily Try to change the trigger coupling into the high frequency suppress and the low frequency suppress to smooth the high frequency or low frequency noise triggered by the interference 5 No Display Responses to the Push down of Run
68. nt of time parameters The SDS series oscilloscopes provide time parameters auto measurements include Frequency Period Rise Time Fall Time Width Width Delay 1 2 Delay 1 2 Duty and Duty Figure 5 54 shows a pulse with some of the time measurement points 64 5 Advanced User Guidebook Ruse Time Fall Time S05 J M Widh e Width Figure 5 54 Rise Time Time that the leading edge of the first pulse in the waveform takes to rise from 10 to 90 of its amplitude Fall Time Time that the falling edge of the first pulse in the waveform takes to fall from 90 to 10 of its amplitude Width The width of the first positive pulse in 50 amplitude points Width The width of the first negative pulse in the 50 amplitude points Delay 1 2 The delay between the two channels at the rising edge Delay 1 2 The delay between the two channels at the falling edge Duty Duty Cycle defined as Width Period Duty Duty Cycle defined as Width Period How to Measure with Cursors Press the Cursor button to display the cursor measurement function menu CURS MEAS in the screen The Cursor Measurement for normal mode The cursor measurement includes Voltage Measurement and Time Measurement at normal mode shown as Figure 5 55 Figure 5 55 CURS MEAS Menu The description of the cursor measurement menu is shown as the following table
69. ode Set vertical channel trigger type as video trigger Select CH1 as the trigger source Select CH2 as the trigger source Source The external trigger input 1 5 of the external trigger source for increasing range of level NTSC Modu PAL Select video modulation SECAM Line Synchronic trigger in video line Field Synchronic trigger in video field Sync Odd Synchronic trigger in video odd filed Even Synchronic trigger in video even field Line NO Synchronic trigger in designed video line turn the M knob to set the line number Mode Auto Acquire waveform even no trigger occurred Holdoff 100ns 10s adjust the M knob to set time interval before another trigger occur Holdoff Reset Set Holdoff time as 100ns 3 Slope Trigger Slope trigger sets the oscilloscope as the positive negative slope trigger within the specified time The Slope Trigger Menu is shown as Figure 5 21 Figure 5 21 Slope trigger menu Slope trigger menu list MENU SETTING INSTRUCTION Singl Set vertical channel trigger type as slope trigger Sree CH1 Select CH1 as the trigger source CH2 Select CH2 as the trigger source 38 5 Advanced User Guidebook Set slope condition turn the M knob to set slope time High level Adjust M knob to set the High level upper limit Low level Adjust M knob to set Low level lower limit Slew rate Slew rate High level Low level Settings Threshold amp SlewRate Auto Acquire waveform even no trigger occurre
70. of the 66 5 Advanced User Guidebook channel CH1 1 Press Cursor and recall the Cursor Measure menu 2 Press the H2 button and choose CH1 for Source 3 Press the H1 button the Type menu will display at the right of the screen Press the F3 button to select Time for Type with two purple dotted lines displayed along the vertical direction of the screen which indicating Cursor 1 and Cursor 2 4 According to the measured waveform adjust the positions of Cursorl and Cursor2 by turning the VERTICAL POSITION knob of CH1 and CH2 The cursor increment window at the left bottom of the waveform shows absolute difference frequency and the present time of the two cursors 4x 0 900ms cg aa Om A HW a BA x1 0 660ms x2 0 240ms 12 5MS s M 500us Depth 100K ff f Figure 5 57 Waveform of Cursor Measurement The Cursor Measurement for FFT mode Press the Cursor button to display the cursor measurement function menu CURS MEAS in the screen which includes Vamp Measurement and Freq Measurement at the mode of FFT shown as Figure 5 58 67 5 Advanced User Guidebook Figure 5 58 CURS MEAS Menu The description of the cursor measurement menu is shown as the following table Function Settin Description OFF Switch off the cursor measurement Type Vamp Display the Vamp measurement cursor and menu Freq Display the Freq measurement cursor and menu When carrying out the cursor measurement the position of Cursor 1 can be a
71. onnection to incompatible equipment c to repair any damage or malfunction caused by the use of non Lilliput supplies or d to service a product that has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty of servicing the product Please contact the nearest Lilliput s Sales and Service Offices for services or a complete copy of the warranty statement For better after sales service please visit www owon com hk and register the purchased product online Excepting the after sales services provided in this summary or the applicable warranty statements Lilliput will not offer any guarantee for maintenance definitely declared or hinted including but not limited to the implied guarantee for marketability and special purpose acceptability Lilliput should not take any responsibilities for any indirect special or consequent damages Table of Contents 1 General Safety KegtiremMe NiS sucscwiverersisansesoteseaustuessunsewiguvarsieapsaredsswewatuessunsemiaeversbenmaresies 1 2 Safety Terms Gnd SVMPOUS viiene i E E A E 2 3 Geheral Characters NOS oreraa A 4 4 Junior User Guidebook csser e O A 5 Introduction to the Structure of the OscilloscopeE sssssssssccecccssssceceeeocossssccccocosssssceccososssssseee 6 Front Pane korna A E A E Re a 6 Leits de Pane huee E E NN 7 Robte SLCC Pane oema a a at hidacdes tit luduinniaduittent ata 7 Rea a1 dc pene Re Rae eer e
72. oose Edge as the mode 10 Press the H2 button to display the Source menu 11 Press the F1 button to choose CH1 as the source 12 Press the H3 button to display the Coupling menu press the F2 button to choose DC as the Coupling 13 Press the H4 button to choose 7 rising as the Slope 14 Rotate the TRIG LEVEL knob and adjust the trigger level to the roughly 50 of the signal to be measured 15 Check the Trigger State Indicator on the top of the screen if it is not Ready push down the Run Stop button and start acquiring wait for trigger to happen If a signal reaches to the set trigger level one sampling will be made and then displayed in the screen By using this approach a random pulse can be captured easily For instance if we want to find a burst burr of high amplitude set the trigger level to a slightly higher value of the average signal level press the Run Stop button and wait a trigger Once there 1s a burr occurring the instrument will trigger automatically and record the waveform during the period around the trigger time By turning the HORIZONTAL POSITION knob in the horizontal control area in the panel you can change the horizontal triggering position to obtain the negative delay making an easy observation of the waveform before the burr occurs see Figure 7 3 0 000ns 62 5M57s M 100us Depth 100K ff f Ea Figure 7 3 Capturing a Single Signal 82 7 Demonstration Example 4 Analyze the Details of a
73. oscilloscope software the connection is successful Figure 6 4 Set the network parameters of the oscilloscope Connect through a router 1 Connection Use a LAN line to connect the oscilloscope with a router the LAN port of the oscilloscope is in the right side panel the computer should be connected to the router too 2 Set the network parameters of the computer Since the oscilloscope can not Support obtaining an IP address automatically you should assign a static IP address The Default gateway and Subnet mask should be set according to the router Here we 76 6 Communication with PC set the IP address to 192 168 1 71 Subnet mask is 255 255 255 0 Default gateway is 192 168 1 1 Internet Protocol TCP IP Properties ty General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate F settings Obtain an IF address automatically IP address Subnet mask Default gateway Use the following DNS server addresses Preferred DNS server 192 Oo 1 24 il Attemate DNS server Figure 6 5 Set the network parameters of the computer 3 Set the network parameters of the OWON Oscilloscope Software Run the software on the computer choose the Ports settings of the Communications menu item
74. pe items will display at the left of screen and turn the M to choose PK PK 12 Press the F4 button the PK PK added completes finish setting of CH2 The measured value will be displayed at the bottom left of the screen automatically see Figure 5 52 12 5M57sS M 500us Depth 100 f 63 5 Advanced User Guidebook Figure 5 52 automatic measurement The automatic measurement of voltage parameters The SDS series oscilloscopes provide automatic voltage measurements including Vpp Vmax Vmin Vavg Vamp Vrms Vtop Vbase Overshoot and Preshoot Figure 5 53 below shows a pulse with some of the voltage measurement points Overshoot Vmax LA Vtop y PP Vamp Vhase Vmin Preshoot Figure 5 53 Vpp Peak to Peak Voltage Vmax The maximum amplitude The most positive peak voltage measured over the entire waveform Vmin The minimum amplitude The most negative peak voltage measured over the entire waveform Vamp Voltage between Vtop and Vbase of a waveform Vtop Voltage of the waveform s flat top useful for square pulse waveforms Vbase Voltage of the waveform s flat base useful for square pulse waveforms Overshoot Defined as Vmax Vtop Vamp useful for square and pulse waveforms Preshoot Defined as Vmin Vbase Vamp useful for square and pulse waveforms Average The arithmetic mean over the entire waveform Vrms The true Root Mean Square voltage over the entire waveform The automatic measureme
75. r Trigger signal comes from two vertical channels when alternate trigger is on This mode is used to observe two unrelated signals You can choose different trigger modes for different channels The options are as follows edge video pulse or slope 1 Alternate trigger Trigger mode Edge Alternate trigger Trigger Type Edge Menu is shown as Figure 5 23 CH1 W ES Figure 5 23 Alternate trigger Trigger Type Edge Menu Alternate trigger Trigger Type Edge Menu list MENU SETTING INSTRUCTION Mode Set vertical channel trigger type as edge trigger Source e ER Select CH1 as the trigger source ee tee CH2 as the trigger source Not allow DC portion to pass Allow all portion pass Couple Not allow high egueney of signal pass and only low frequency portion pass Not allow low frequency of signal pass and only high frequency portion pass Slope Trigger in signal rising edge P Trigger in signal falling edge Auto Acquire waveform even no trigger occurred Holdoff 100ns 10s adjust M knob to set time interval before another trigger occur Reset Set Holdoff time as 100ns Mode Holdoff 40 5 Advanced User Guidebook 2 Alternate trigger Trigger Mode video Alternate trigger Trigger Type video Menu is shown as Figure 5 24 Figure 5 24 Alternate trigger Trigger Type video Menu Alternate trigger Trigger Type video Menu list MENU SETTING INSTRUCTION Alternate Mode Set vertical channel trigger
76. re details please see Save Function Menu on P50 73 6 6 Communication with PC Communication with PC SDS series digital storage oscilloscope support communications with a PC through USB LAN or COM port You can use the Oscilloscope communication software to store analyze display the data and remote control Here is how to connect with PC First install the Oscilloscope communication software on the supplied CD Then there are several ways of connection to choose from Using USB Port 1 2 3 Connection Use a USB data cable to connect the USB Device port in the right panel of the Oscilloscope to the USB port of a PC Install the driver Run the Oscilloscope communication software on PC press F1 to open the help document Follow the steps of title I Device connection in the document to install the driver Port setting of the software Run the Oscilloscope software click Communications in the menu bar choose Ports Settings in the setting dialog choose Connect using as USB After connect successfully the connection information in the bottom right corner of the software will turn green OFON Oscilloscope Software 2 0 8 11 File View Format Communications Language Help gt o Hel 2400 88 0 CHI Cursor Divisiess 1010 2 52 Typa Nene CHI Time Biv acala 50s CHI Velt Div Teale 5 00 Y CHL PaveFera In s Type Frequency Faried FE FE To FFT Inver ted D Progr
77. rms and Symbols A Warning The channels should adopt common basis during measuring To prevent short circuits the 2 probe ground must not be connected to 2 different non isolated DC level The diagram of the oscilloscope ground wire connection Probe Oscilloscope Electrical Outlet Signal Input Power Cord Ground Clip The diagram of the ground wire connection when the battery powered oscilloscope is connected to the AC powered PC through the ports Probe Oscilloscope PC Electrical Outlet Battery power USB VGA COM aoe LAN Cable Ground Clip It is not allowed to measure AC power when the oscilloscope is AC powered or when the battery powered oscilloscope is connected to the AC powered PC through the ports Warning To avoid fire or electrical shock when the oscilloscope input signal connected is more than 42V peak 30Vrms or on circuits of more than 4800VA please take note of below items Only use accessory insulated voltage probes and test lead Check the accessories such as probe before use and replace it if there are any damages Remove probes test leads and other accessories immediately after use Remove USB cable which connects oscilloscope and computer Do not apply input voltages above the rating of the instrument because the probe tip voltage will directly transmit to the oscilloscope Use with caution when the probe is set as 1 1 Do not use exposed metal BNC or
78. rms dB 1 00001KHz _f 800mv 0 00div Dual Win FFT Math Figure 5 12 Hanning window Won 0 000Hz 1 00000KHz _f 800mv 55578 20Hz poi o 0 00div Dual Wfm PET Math Figure 5 13 Blackman window Notes for using FFT E Use Zoom function to magnify the FFT waveform if necessary M Use the default dB scale for details of multiple frequencies even if they have very different amplitudes Use the Vrms scale to compare frequencies E DC component or offset can cause incorrect magnitude values of FFT waveform To minimize the DC component choose AC Coupling on the source signal E To reduce random noise and aliased components in repetitive or single shot events set the oscilloscope acquisition mode to average 31 5 Advanced User Guidebook What is Nyquist frequency The Nyquist frequency is the highest frequency that any real time digitizing oscilloscope can acquire without aliasing This frequency is half of the sample rate Frequencies above the Nyquist frequency will be under sampled which causes aliasing So pay more attention to the relation between the frequency being sampled and measured Note In FFT mode the following settings are prohibited 1 Window set 2 XY Format in Display SET 3 Measure Use VERTICAL POSITION and VOLTS DIV Knobs 1 The VERTIVAL POSITION knob is used to adjust the vertical positions of the waveforms including the captured waveforms and calculated waveforms
79. rrent sample rate and the record length It indicates the measured type and value of the corresponding channel F means frequency T means cycle V means the average value Vp the peak peak value Vk the root mean square value Ma the maximum amplitude value Mi the minimum amplitude value Vt the Voltage value of the waveform s flat top value Vb the Voltage value of the waveform s flat base Va the amplitude value Os the overshoot value Ps the Preshoot value RT the rise time value FT the fall time value PW the width value NW the Width value D the Duty value D the Duty value PD the Delay A B value and ND the Delay A gt B value The readings indicate the corresponding Voltage Division and the Zero Point positions of the channels The icon shows the coupling mode of the channel indicates direct current coupling indicates AC coupling AED l indicates GND coupling It is cursor measure window showing the absolute values and the readings of the two cursors The yellow pointer shows the grounding datum point zero point position of the waveform of the CH2 channel If the pointer is not displayed it shows that this channel is not opened The red pointer indicates the grounding datum point zero point position of the waveform of the CH1 channel If the pointer is not displayed it shows that the channel is not opened l1 4 Junior User Guidebook How to Implement the
80. s shown as follows Setting Sample __ Normal sampling mode Use to capture maximal and minimal samples Finding highest and lowest points Peak detect over adjacent intervals It is used for the Sample detection of the jamming burr and the possibility of reducing the confusion It is used to reduce the random and don t care A 4 16 64 12 VETERE AD a tee noises with the optional number of averages 44 5 Advanced User Guidebook The description of the Record Length Menu is shown as follows Setting Length Choose the record length Change the ACQU Mode settings and observe the consequent variation of the wave form displayed WON Average 16 f 0 00mv 12 57S M 500us Depth 100K FBequ Mode Length Figure 5 28 Peak Detect mode under which the burrs on the falling edge of the square wave can be detected and the noise is heavy Acgqu Mode J sample Peak a Average 16 Orme E 12 5M57s M 500us Depth 100K Length Figure 5 29 Normal ACQU Mode display in which no burr can be detected 45 5 Advanced User Guidebook 0 000ns 1 36 oo 12 5MS s M 500us Depth 100K Figure 5 30 The displayed waveform after the noise is removed under the Average Mode in which the average number of 16 is set How to Set the Display System Press the Display button and the menu displayed in the screen is shown as Figure 5 31 Figure 5 31 Display
81. see Figure 7 1 0 000ns 12 5MS8 s M 500us Depth 100K fi f Figure 7 1 Measure Frequency and PK PK value for a given signal Example 2 Gain of a Amplifier in a Metering Circuit The purpose of this example is to work out the Gain of an Amplifier in a Metering Circuit First we use Oscilloscope to measure the amplitude of input signal and output signal from the circuit then to work out the Gain by using given formulas Set the probe menu attenuation coefficient as 10X and that of the switch in the probe as 10X see How to Set the Probe Attenuation Coefficient on P14 Connect the oscilloscope CH1 channel with the circuit signal input end and the CH2 channel to the output end Operation Steps 1 Press the Autoset button and the oscilloscope will automatically adjust the waveforms of the two channels into the proper display state 2 Press the Measure button to show the Measure menu 3 Press the H1 button 4 Press the F2 button and choose CH1 5 Press the F1 button and turn the M knob to choose PK PK 6 Press the F2 button and choose CH2 7 Press the F1 button again and turn the M knob to choose PK PK 8 Read the peak to peak voltages of Channel 1 and Channel 2 from the bottom left 80 7 Demonstration of the screen see Figure 7 2 9 Calculate the amplifier gain with the following formulas Gain Output Signal Input signal Gain db 20xlog gain O0 000ns 12 5M5 s M 500us Depth 100K ff f
82. sk should be set according to the router Press the H3 button to select Save set it prompts reset to update the config After resetting the oscilloscope if you can get data normally in the oscilloscope software the connection is successful Figure 6 7 Set the network parameters of the oscilloscope Using COM Port 1 Connection Use a data cable to connect the COM port in the right panel of the Oscilloscope to the COM port of a PC 2 Port setting of the software Run the Oscilloscope software click Communications in the menu bar choose Ports Settings in the setting dialog choose Connect using as COM To learn about how to operate the software you can press F1 in the software to open the help document 78 7 Demonstration 7 Demonstration Example 1 Measurement a Simple Signal The purpose of this example is to display an unknown signal in the circuit and measure the frequency and peak to peak voltage of the signal 1 Carry out the following operation steps for the rapid display of this signal 1 Set the probe menu attenuation coefficient as 10X and that of the switch in the probe switch as 10X see How to Set the Probe Attenuation Coefficient on P14 2 Connect the probe of Channel 1 to the measured point of the circuit 3 Press the Autoset button The oscilloscope will implement the Autoset to make the waveform optimized based on which you can further regulate the vertical and horizontal div
83. t the product will be free from defects in materials and workmanship for a period of 3 years from the date of purchase of the product by the original purchaser from the Lilliput Company And the warranty period of accessories such as probe battery is 12 month This warranty only applies to the original purchaser and is not transferable to the third party If the product proves defective during the warranty period Lilliput either will repair the defective product without charge for parts and labor or will provide a replacement in exchange for the defective product Parts modules and replacement products used by Lilliput for warranty work may be new or reconditioned to like new performance All replaced parts modules and products become the property of Lilliput In order to obtain service under this warranty Customer must notify Lilliput of the defect before the expiration of the warranty period Customer shall be responsible for packaging and shipping the defective product to the service center designated by Lilliput and with a copy of customer proof of purchase This warranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care Lilliput shall not be obligated to furnish service under this warranty a to repair damage resulting from attempts by personnel other than Lilliput representatives to install repair or service the product b to repair damage resulting from improper use or c
84. time before it is changed again AN Caution The default attenuation coefficient of the probe on the instrument is preset to 10X Make sure that the set value of the attenuation switch in the probe is the same as the menu selection of the probe attenuation coefficient in the oscilloscope The set values of the probe switch are 1X and 10X see Figure 4 10 14 4 Junior User Guidebook en Figure 4 10 Attenuation Switch A Caution When the attenuation switch is set to 1X the probe will limit the bandwidth of the oscilloscope in SMHz To use the full bandwidth of the oscilloscope the switch must be set to 10X How to Use the Probe Safely The safety guard ring around the probe body protects your finger against any electric shock shown as Figure 4 11 A Figure 4 11 Finger Guard A N Warning To avoid electric shock always keep your finger behind the safety guard ring of the probe during the operation To protect you from suffering from the electric shock do not touch any metal part of the probe tip when it is connected to the power supply Before making any measurements always connect the probe to the instrument and connect the ground terminal to the earth How to Implement Self calibration The self calibration application can make the oscilloscope reach the optimum condition rapidly to obtain the most accurate measurement value You can carry out this application program at any time This program must be exec
85. to the EXT TRIG connector Ext uses the signal directly it has a trigger level range of 0 6V to 0 6V The EXT 5 trigger source attenuates the signal by 5X which extends the trigger level range to 3V to 3V This allows the oscilloscope to trigger on a larger signal AC Line AC power can be used to display signals related to the power line frequency such as lighting equipment and power supply devices The oscilloscope gets triggered on its power cord so you do not have to input an AC trigger signal When AC Line is selected as trigger source the oscilloscope automatically set coupling to DC set trigger level to OV Trigger Mode The trigger mode determines how the oscilloscope behaves in the absence of a trigger event The oscilloscope provides three trigger modes Auto Normal and Single Auto This sweep mode allows the oscilloscope to acquire waveforms even when 3 it does not detect a trigger condition If no trigger condition occurs while the oscilloscope is waiting for a specific period as determined by the time base setting it will force itself to trigger Normal The Normal mode allows the oscilloscope to acquire a waveform only when it is triggered If no trigger occurs the oscilloscope keeps waiting and the previous waveform if any will remain on the display Single In Single mode after pressing the Run Stop key the oscilloscope waits for trigger While the trigger occurs the oscilloscope acquires one wave
86. type as video trigger CH2 Select CH2 as the trigger source NTSC Select video modulation SECAM Line Synchronic trigger in video line Field Synchronic trigger in video field Odd Field Synchronic trigger in video odd filed Even Field Synchronic trigger in video even field Line NO Synchronic trigger in designed video line turn the M knob to set the line number Auto Acquire waveform even no trigger occurred Holdoff 100ns 10s adjust the M knob to set time interval before another trigger occur Reset Set Holdoff time as 100ns Mode Holdoff 3 Alternate trigger Trigger Mode Slope Alternate trigger Trigger Type Slope Menu is shown as Figure 5 25 Figure 5 25 Alternate trigger Trigger Type Slope Menu Alternate trigger Trigger Type Slope menu list MENU SETTING INSTRUCTION Alternate Set vertical channel trigger type as slope trigger Grace CH1 Select CH1 as the trigger source CH2 Select CH2 as the trigger source ee Select slope condition When Set slope condition turn the M knob to set time 4 5 Advanced User Guidebook High level Turn the M knob to set the High level Threshold Low level Turn the M knob to set Low level Slew rate Slew rate High level Low level Settings Auto Acquire waveform even no trigger occurred Holdoff 100ns 10s adjust the M knob to set time interval before another trigger occur Reset Set Holdoff time as 100ns Mode Holdoff 4 Alternate trigg
87. types need to be deleted Remove the chosen measure type Add the selected measure types shown Add at the left bottom you could only add 8 types at most Remove Type Measure The measured values can be detected on each channel simultaneously Only if the waveform channel is in the ON state the measurement can be performed The 62 oe a 5 Advanced User Guidebook automatic measurement cannot be performed in the following situation 1 On the saved waveform 2 On the mathematical waveform 3 On the XY format 4 On the Scan format Measure the frequency the peak to peak voltage of the Channel CH1 and the mean the RMS of the Channel CH2 following below steps Press the Measure button to show the automatic measurement function menu Press the H1 button to display the Add menu Press the F2 button and choose CH1 as the source Press the F1 button the type items will display at the left of screen and turn the M knob to choose Period Press the F4 button the period options added completes 6 Press the F1 button again the type items will display at the left of screen and turn the M to choose Freq Press the F4 button the frequency added completes finish setting of CH1 Press the F2 button and choose CH2 as the source Press the F1 button the type items will display at the left of screen and turn the M to choose Mean 10 Press the F4 button the Mean added completes 11 Press the F1 button the ty
88. unction How to Use Executive Buttons It 1s recommended that you read this chapter carefully to get acquainted the various measurement functions and other operation methods of the SDS series oscilloscope 19 5 Advanced User Guidebook How to Set the Vertical System The VERTICAL CONTROLS includes three menu buttons such as CH1 MENU CH2 MENU and Math and four knobs such as VERTICAL POSITION VOLTS DIV for each channel Setting of CH1 and CH2 Each channel has an independent vertical menu and each item is set respectively based on the channel To turn waveforms on or off channel math Pressing the CH1 MENU CH2 MENU or Math buttons have the following effect e If the waveform is off the waveform is turned on and its menu is displayed e If the waveform is on and its menu is not displayed its menu will be displayed e If the waveform is on and its menu is displayed the waveform is turned off and its menu goes away Couple setting Probe setting Limit setting Figure 5 1 Channel Setting Menu SDS6062 V SDS7072 V do not have Limit menu 20 5 Advanced User Guidebook The description of the Channel Menu is shown as the following list Menu DC Pass both AC and DC components of the input signal Coupling AC Block the DC component of the input signal GROUND Disconnect the input signal mes ore Dyas Inverted haa OFF Display original waveform XI Match this to the probe attenuation factor to have an Att
89. uted whenever the change of ambient temperature is 5 C or over Before performing a self calibration disconnect all probes or wires from the input connector Press the Utility button then press H1 button to call out the Function 15 4 Junior User Guidebook menu turn the M knob to choose Adjust Press H2 button to choose the option Self Cal run the program after everything 1s ready Introduction to the Vertical System As shown in Figure 4 12 there are a few of buttons and knobs in VERTICAL CONTROLS The following practices will gradually direct you to be familiar with the using of the vertical setting Figure 4 12 Vertical Control Zone 1 Use the button VERTICAL POSITION knob to show the signal in the center of the waveform window The VERTICAL POSITION knob functions the regulating of the vertical display position of the signal Thus when the VERTICAL POSITION knob is rotated the pointer of the earth datum point of the channel is directed to move up and down following the waveform Measuring Skill If the channel is under the DC coupling mode you can rapidly measure the DC component of the signal through the observation of the difference between the wave form and the signal ground If the channel is under the AC mode the DC component would be filtered out This mode helps you display the AC component of the signal with a higher sensitivity Vertical offset back to 0 shortcut key Turn the VERTICAL POSITIO
90. y just pressing the Copy panel button in any user interface If the Storage of the save menu is set as External you should install the USB disk Please refer to the contents below to install the USB disk and name the file to be saved Save the current screen image The screen image can only be stored in USB disk so you should connect a USB disk with the instrument l Install the USB disk Insert the USB disk into the 1 USB Host port of Figure 4 3 Right side panel If an icon appears on the top right of the screen the USB disk is installed successfully The supported format of the USB disk The storage capacity should not exceed 8G 16G or above is not supported FAT32 file system cluster size cannot exceed 4K Once the USB disk cannot be recognized you could format it into the supported format and try again After the USB disk is installed press the Save panel button the save menu is displayed at the bottom of the screen Press the H1 button the Type menu will display at the left of screen turn the M knob to choose Image for Type Press the H4 button the input keyboard used to edit the file name will pop up The default name is current system date Turn the M knob to choose the keys press the M knob to input the chosen key The length of file name is up to 25 characters Choose and press the Enter key of the keyboard to end the input and store the file with the current name 52 5 Advanced User Guidebook fU