Home
Access5800 Series User Manual
Contents
1. Ult coiere etie veo Eai 7 H AnstallatlOlc mctu ia IUE ue E era SP Seen eT E US 8 4 1 Access Point Mechanical Installation 8 4 2 Subscriber Unit Mechanical Installation 8 A MM a 16 RN NR a RR 10 5 Appendix Unit Configuration Default Information 12 3 USER MANUAL Rev D Access5800 Series User Manual 1 For your safety WARNING AN Use extreme care when installing antennas near power lines CAUTION Do not apply power to the transmitter until the antenna is connected Permanent damage may result CAUTION When the unit is in operation avoid standing directly in front of the antenna Strong RF fields are present when the transmitter is on 2 Welcome Thank you for choosing Trango Broadband Wireless to fulfill your wireless Internet access needs You are now on your way to using a high speed wireless link which can serve as an alternative to conventional wiring where such wiring is impractical too slow or too expensive The wireless link requires at least one Access Point Unit and one Subscriber Unit An Access Point can manage up to five hundred Subscriber Units per sector A sector is defined as a 60 degree azimuth by 10 degree elevation coverage area that an Access Point s integrated antenna covers The system utilizes robust spread spectrum technology to reduce susceptibility to interference 2 1 Doc
2. to a power outlet on a different circuit from that which the receiver is connected to 4 Consult the dealer and or experienced radio TV technician for help FCC ID NCYM5800SBAP60 FCC ID NCYM5800SBSUEXT Canada 2945A 12100 IMPORTANT NOTE Intentional or unintentional changes or modifications must not be made unless under the express consent of the party responsible for compliance Any such modifications could void the user s authority to operate the equipment and will void the manufacturer s warranty To comply with FCC RF exposure requirements the following antenna installation and device operating configurations must be satisfied The antenna for this unit must be fixed and mounted on outdoor permanent structures with a separation distance of at least two meters from all persons Furthermore it must not be co located or operating in conjunction with any other antenna or transmitter 2 USER MANUAL Rev D Access5800 Series User Manual Table of Contents L ODyOuUlsSalebccasnisueud ts enne a nen EUG 4 2 WECOME Mee Ree een een me Mad MA MD E MA E MA DEAE 4 2 1 Documentation conventions eeeeeeeeeeeee eene 4 2 2 neck MN Cena tee taht tuas ID I MM E MEE CEDE IAE 5 2 SOT Gt a E EE EM M E S E EI 5 3 Components and features ssssssssseeeeeee eene 6 3 Access Point Unit euueueeeseeeeeeeeeee nennen nnn nnns 6 Bez WI CCl OM BOX aae ated Panes nice AEN E ELM emanates 6 3 3 9UDSCPIDef
3. NEE ystems Inc SN THE LEADER IN FHRELESS FOEU Access5800 Series User Manual August 2002 Trango Broadband Wireless 9939 Via Pasar San Diego California 92126 T 858 653 3900 F 858 621 2725 Access5800 Series User Manual FCC Information This device complies with Part 15 of FCC Rules and Regulations Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with these instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in any particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to correct the interference by one of more of the following measures 1 Reorient the antenna 2 Increase the separation between the affected equipment and the unit 3 Connect the affected equipment
4. e maximum cable length from the J unction Box to the unit AP or SU is 100 meters 328feet Please note that the maximum cable length from the radio to PC hub switch is 100 meters 328 feet as specified in the Ethernet standard 11 USER MANUAL Rev D Access5800 Series User Manual 5 Appendix Unit Configuration Default Information ap default cfg Base ID 1 AP ID 1 LEPI 192 109 0 1 Default Opmode off Service Range 10 miles MIR Threshold off MIR Threshold Kbps 6144 RF Channel 1h 5736 MHz RE Rx Threshold ott Channel Table Ch 1 5736 MHz Ch 2 5756 MHz Ch 3 5776 MHz Ch 4 5796 MHz Ch 5 5816 MHz Ch 6 5836 MHz Broadcast Packet block Remarks su default cfg Base ID 1 DE 09269051 Default Opmode off Channel Table Ch 1 5736 MHz Ch 2 5756 MHz Ch 3 5776 MHz Ch 4 5796 MHz Ch 5 5816 MHz Ch 6 5836 MHz Channel Scan Sequence 1h 2h 3h 4h 5h 6n SU XB 1 Broadcast Packet block Auto Scan AP on ICEZIP TOT AP off Remarks 12 USER MANUAL Rev D
5. it Radome Mounting bolt with lockwasher V brackets incl gt Ethernet connection and power Serial connection inside access door Bottom LED s display TX red RX green RSSI yellow 3 2 J unction Box The J unction Box provides power to AP or SU via unused leads in a Shielded Twisted pair STP Ethernet cable The ODU port in the diagram below connects to AP or SU using 8 conductor STP Indicates voltage to J Box OK NET port RJ 45 Indicates AP or SU drawing current ODU port RJ 45 Power port 20 Vdc 6 USER MANUAL Rev D 3 3 Subscriber Unit The Subscriber Unit interfaces with end users via Ethernet devices such as network switch hub or a PC network interface card NIC Front Installed on dish antenna mounting arm Access5800 Series User Manual SubscriberUnit Back Antenna ports H amp V Mounting bolt and lockwasher 4 V brackets incl Dishantenna Feed arm Feed FlangeEthernet connection and power Serialconnection inside access door LEDdisplay TX red RX green RSSl yellow Bottom USER MANUAL Rev D Access5800 Series User Manual 4 Installation 4 1 Access Point Mechanical Installation 1 Mount the arm to 2 Mount the AP to 3 Align antenna an earth grounded the mounting arm mast or secured wall U bolts required for mast mount 4 2 Subscriber Unit Mechanical Installation 1 Mount the arm to 2 A
6. ssemble the 3 Mount the dish an earth grounded antenna dish and to the mounting mast or a secured feed arm upper left arm wall U bolts picture The lower required for mast right picture shows mount the dish with feed arm 8 USER MANUAL Rev D 4 Mount the feed 5 Adjust the to the feed arm mounting arm to horizontal level 7 Connect one end 8 If the AP is at the of two RF cables to horizon rotate the dish the feed and run to the 50 mark other end through feed arm to the SU 10 Slightly adjust the dish antenna up and down left and right until the strongest RSSI is reached Then tighten down the bolts Access5800 Series User Manual 6 Mount SU on the mounting arm 9 If the AP is not at the horizon use the 50 mark as the offset point and direct the SU antenna up or down until the RSSI is acceptable USER MANUAL Rev D Access5800 Series User Manual 4 3 Wiring Wiring diagram is shown as below please note that the J unction Box is an indoor device that requires a dry environment STP stands for shielded twisted pair and UTP for unshielded twisted pair AP AP Wiring Switch 3 UTPor I EIS STP 20 Vdc AO we 120V 50 60 Hz Switch sU LNA SU Wiring Switch aa UlPor RR GTP STP 20 Vdc e 120V 50 60 Hz STP PC O UTPorSTP Ee E LL crossover 20 Vdc 120V 50 60 Hz 10 USER MANUAL Rev D Access5800 Series User Manual Th
7. umentation conventions Convention Description Bold Indicates emphasized text BON Bampa Note oo Italic Indicates a file name eS trample ap default cfg Bold amp italic Indicates a user command Example tftp Courier Indicates contents in a file few MI Courier Indicates descriptions of New file contents 4 USER MANUAL Rev D Access5800 Series User Manual 2 2 Check list For each package you receive you should have the following items Bolts for Mounting Brackets 4 H938 Lockwashers for Mounting Brackets 4 H 9137 Bolts for Mounting Brackets 4 H 9138 Lockwashers for Mounting Brackets 4 H 9137 Bolts for Mounting Brackets 4 H938 Lockwashers for Mounting Brackets 4 H 9137 If any items are missing notify your sales representative If an item appears to be damaged from shipment replace it in its packing material and notify the shipper 2 3 Service If the unit ever needs repair service contact your service provider or an authorized Trango Broadband Wireless distributor for return authorization and shipping instructions 5 USER MANUAL Rev D Access5800 Series User Manual 3 Components and features 3 1 Access Point Unit The Access Point Unit coordinates and manages Ethernet packet flow based on a point to multipoint Broadband Wireless Access architecture Access Point Un
Download Pdf Manuals
Related Search
Related Contents
DL-2 Software Manual HP LaserJet 8100 8150 Service Manual Easylon Serial Socket Interface User Manual eMPPT30 series controller User`s manual Everbilt 14455 Instructions / Assembly 6712 Portable Sampler User Manual ALERTS IN VIENNA ADVANTAGE "取扱説明書" Teledex Telephone BTX4750 User's Manual User Manual Copyright © All rights reserved.