Home
User Manual - Bion Technologies
Contents
1. Dimensions are in millimeters inch All product specifications are subject to change without prior notice Description PDA N funis m round a Lv A4 TECHNOLOGIES Revision Scale 1 5 Page 214 www biontechnologies com 5 MP VN Mounting 1 Mounting funis m round F ee ow at gt zt oe c s gt ge Et wo 26 1 Mounting Before installing funis fixtures make sure that all junction boxes switches and dimmers have been installed Make sure the power is OFF and the mounting spot provides enough solidity Reasure that you have read and understood the safety instructions within this user manual 2 Installation pendant Install the provided plate and adjust like the favored direction Adjust the pending height by pushing the steel rope into the housing adjust the wire length loosening the strain relief on the powersupply housing and roll the spare wire Dont forget to tighten the strain relief again Use the provided cable clamps to join the wires Install the powersupply housing with provided screws on the plate Assure you have tightened all screws and check again 6 www biontechnologies com Maintenance Clean device from dirt and residue regularly Use solvent free cleaning agents only and do not employ aggressive chemicals or high pressure cleaner Operate device only after complete drying Conformity FEMCE Manufacturer pura Bion Technologies IT a brand o
2. den technischen Daten angegebene Betriebstemperatur zu beachten Beim Bohren der Befestigungsl cher ist darauf zu achten dass die Netzleitungen nicht besch digt werden Litzendr hte d rfen nicht verl tet werden Es sind Aderendh lsen zu verwenden Spannungskennzeichnung auf dem Betriebsger t beachten Ein einwandfreier elektrischer bergang ist beim Anschlie en der Leuchte zu gew hrleisten Die Leuchte darf nicht ge ffnet werden Kein Gewahrleistungsfall Jegliche Ver nderung ist untersagt Der Hersteller bernimmt keine Haftung durch Sch den die durch Ver nderung unsachgem en Einsatz oder fehlerhafte Montage entstehen Ger t trocken lagern und vor Besch digung sch tzen 8 www biontechnologies com Lieferumfang Packen Sie alle Teile aus Pr fen Sie den Verpackungsinhalt auf sichtbare Transportsch den Pr fen Sie ob der Verpackungsinhalt vollst ndig ist Im Lieferumfang enthalten funis m Leuchte in gew nschter Ausf hrung Montageplatte Original Bedienungsanleitung Wenn Sie Transportsch den oder Unstimmigkeiten zwischen dem hier angegebenen Lieferumfang und Verpackungsinhalt feststellen informieren Sie unverz glich Ihre Verkaufstelle www biontechnologies com 9 Technische Daten Abmessungen Durchmesser 100 mm 3 94 in Abmessungen 310 mm 465 mm 12 21 in 18 31 in Leuchtentyp 4 D pureWhite Farbtemperaturen pureWhite 3000 K 4000 K Projektbezogene Farbtemperatu
3. device Make sure flawless electrical connectivity is provided Connecting the lamp to the powered up device can cause damage to the lamp voids product warranty No modification allowed No liability will be assumed in case of damage incurred by alteration improper use or faulty installation 2 www biontechnologies com Scope of delivery Check completeness of supplied device immediately after receipt In delivery included funis m LED fixture Mounting Plate Original User Manual If you detect any transportation damage or differencies between specified packing contents and your unpacked delivery please contact your dealer immediately www biontechnologies com 3 Technical Data Dimensions Diameter 100 mm 3 94 in 310 mm 465 mm 12 21 in 18 31 in 3000 K 4000 K Project specific color temperature for pureWhite available Housing Color s 4 www biontechnologies com Non dimmable Dimmable TRIAC CE non dimmable dimmable via Triac AC ETLus non dimmable dimmable via Triac AC CETL non dimmable Aluminium Signal Jet black Dark grey Grey brown Gold RAL white RAL RAL 9005 RAL 9023 RAL 8019 1036 9003 Others colors available upon request PMMA 155 mm 6 10 in 1 4kg 3 09 Ibs 310 mm 12 20 in 2 1 kg 4 63 Ibs 465 mm 18 31 in 2 8kg 6 17 lbs Ingress Protection IP20 Environment A indoor Warranty 24 Months Certification TD FC Engineering Drawing
4. ES is N TECHNOLOGIES gt BCE a Fe funis m round 2000 pureWhite Arm NRAANII IA gt lt VMIFAINUJ FAL Vol 3 Inna Ea LEITUNG www biontechnologies com USER MANUAL funis m round 2000 pureWhite Safety Instructions Devices must be installed by qualified personnel in compliance with all pertaining regulations Always refer to the technical parameters in the data sheet All items are subject to technical modification Refer to the attached User Manual as a basis for correct use Consult circuit diagram for correct wiring Note Before attempting any work make sure device is separated from main power Protect device from moisture Make sure protection against line voltage shock is provided during installation We recommend securing the installation by RCD circuit breakers Note that adjacent parts or devices must be temperature proof up to 90 C Do not operate the fixture with inductive consumers fluorescent lamps gas discharge lamps ventilators etc in the same electric circuit Activation of inductive consumers can cause damage to the operating device Do not place heat insulation material on the fixture Mind the operating temperatures of the fixture according to the technical data sheet Before drilling the mounting holes take precautions not to harm or damage any power lines Do not solder cable strands Use cable strand sleeves instead Note and mind voltage label on the
5. S All rights reserved Subject to change Specifications may change without notice www biontechnologies com 13 Elm TECHNOLOGIES Lindberghstrasse 15 86343 Koenigsbrunn Tel 49 0 8231 95787 0 Fax 49 0 8231 95787 29 www biontechnologies com info biontechnologies com YouTube http www youtube com BIONTECHNOLOGIES 2013 BION TECHNOLOGIS is a brand of ONELED DE GMBH All rights reserved Subject to change Specifications may change without notice
6. en Sie die rtlichen Vorgaben zur Installation von elektrischen Ger ten sowie die Sicherheitshinweise dieser Bedienungsanleitung S mtliche Arbeiten sind ohne Spannung durchzuf hren 2 Montage Pendelleuchte Montieren Sie die mitgelieferte Grundplatte und richten sie diese gem der gew nschten Leuchtenposotion aus Die Pendelh he kann eingestellt werden indem das Stahlseil weiter in den Leuchtenk rper geschoben wird bzw herausgezogen wird indem die F hrung der Seilklemme nach innen gedr ckt wird Die Leitung kann durch l sen der Zugentlastung im Deckenanbaugeh use in dessen verstaut werden Stellen Sie sicher dass die Zugentlastung danach wieder einrastet Stellen Sie die Elektrische Verbindung mit den Leuchtenklemmen aus dem Lieferumfang her Befestigen Sie das Deckenanbaugeh use mit den Schrauben aus dem Lieferumfang an der Grundplatte Vergewissern Sie sich auf festen Sitz aller Schrauben und pr fen Sie diese eventuell nochmals nach 12 www biontechnologies com Wartung Pflege Ger t regelm ig mit einem feuchten Tuch reinigen Verwenden Sie ausschlie lich l sungsmittelfreie Reinigungsmittel und verwenden Sie keine Chemikalien Konformitat FEMCE Hersteller pura Bion Technologies IT a brand of oneled de GmbH Lindberghstrasse 15 YR ot MN a 86343 Koenigsbrunn Tel 49 0 8231 95787 0 Fax 49 0 8231 95787 29 www biontechnologies com info biontechnologies com YouTube http www youtube com BIONTECHNOLOGIE
7. f oneled de GmbH Lindberghstrasse 15 YR ot MN a 86343 Koenigsbrunn Tel 49 0 8231 95787 0 Fax 49 0 8231 95787 29 www biontechnologies com info biontechnologies com YouTube http www youtube com BIONTECHNOLOGIES All rights reserved Subject to change Specifications may change without notice www biontechnologies com 7 BEDIENUNGSANLEITUNG funis m round 2000 pureWhite Sicherheitshinweise Anschluss und Bedienung dieses Ger ts sollte ausschlie lich von qualifiziertem Fachpersonal in bereinstimmung mit allen geltenden Vorschriften erfolgen Beachten Sie immer die technischen Daten auf dem Datenblatt Technische Anderungen vorbehalten Die beigef gte Gebrauchsanleitung ist Voraussetzung f r den ordnungsgem en Gebrauch Die Aderbelegung ist gem Schaltschema zu beachten Achtung Vor Beginn der Arbeiten ist die Netzleitung spannungsfrei zu schalten Ger t vor N sse sch tzen Der Schutz gegen elektrischen Schlag ist beim Einbau sicherzustellen Wir empfehlen die bauseitige Absicherung ber einen Fehlerstrom Schutzschalter Beim Einbau ist darauf zu achten dass benachbarte Bauteile einer Temperatur von 90 C standhalten Leuchte nicht gemeinsam mit induktiven Lasten Leuchtstofflampen Entladungslampen Ventilatoren usw im gleichen Stromkreis betreiben Beim Schalten induktiver Lasten k nnen Defekte an der Leuchte entstehen W rmed mmung darf nicht auf der Leuchte liegen Beim Einbau ist auf die in
8. ren f r pureWhite m glich Dimmung Nicht dimmbar Dimmbar TRIAC CE statisch dimmbar via Triac AC ETLus statisch dimmbar via Triac AC CETL statisch Eingangsspannung Netzteil intern Wileistungsaufahme Max28W 00 Bindleistungskompensation 9 Sehutzklasse Emschaltom 0 IDAQ230VA 0000 Betriebstemperaturbreich 20 C 430 C 4 F 482 F 0000 Lebensdauer LT 80000h 25 C 77 F LEDKase 1 Klasse 2LED Produkt 0 Gehiuse Alumilum 0 Geh usefarbe n MEN NENNEN NENNEN ENNNUND Signalweif3 Tiefschwar Dunkelgrau Graubraun Gold RAL RAL 9003 zRAL 9005 RAL 9023 RAL 8019 1036 Weitere Farben auf Kundenwunsch m glich Gewicht 155 mm 6 10 in 1 4kg 3 09 Ibs 310 mm 12 20 in 2 1 kg 4 63 Ibs 465 mm 18 31 in 2 8kg 6 17 lbs 10 www biontechnologies com Umgebung A indoor Gew hrleistung 24 Monate sm CE FE Technische Zeichnung Description 1 5 PDA N funis m round a Lv A4 TECHNOLOGIE S Roison Page 214 Dimensions are in millimeters inch All product specifications are subject to change without prior notice www biontechnologies com 11 Montage 1 Deckenmontage funis m round mE uo ee ow at gt zt oe z 2 2 ge Et wo 28 1 Allgemeine Informationen Untergrundbeschaffenheit Achten Sie auf ausreichende Festigkeit des Untergrunds wenn Sie die Leuchte montieren Geeignete Schrauben sind zu verwenden max 5mm Durchmesser Beacht
Download Pdf Manuals
Related Search
Related Contents
Lenco BT-4650 U326S GESTION DES OUVRAGES D`ART Using the DAQ Adaptor for MATLAB Hama Croc Philips 51008GPX1 air purifier Télécharger Copyright © All rights reserved.
Failed to retrieve file