MoAnLtg_RM40Li VdS_NEU.indd
Contents
1. pipes or other important components behind them If in doubt consult an expert before drilling If you are fitting the wireless smoke detector in a vehicle such as a camper or caravan you must contact the manufacturer or your local dealer first for information on the most suitable location 1 Loosen the wireless smoke detector from the base of the housing by turning it anticlockwise Mark the drill holes through the base 2 Drill the holes put in the plugs and screw in the base 3 Insert the battery see diagram and fasten the wireless smoke detector by twisting it clockwise onto the base The detector has a safety device that prevents installation without a battery 4 If you cannot fasten the wireless smoke detector to the base Check whether the battery is correctly inserted and connected Operation and function test The wireless smoke detector is ready for use as soon as you put in the battery The smoke detector can be used alone or with other RM40 Li detectors connected wirelessly offering a greater level of safety Under the housing cover there is an indicator lamp which flashes every 30 seconds to show that the battery is correctly inserted and is delivering enough power to generate an alarm Check the function of the smoke detector at regular intervals Press the test button the lower section of the housing cover for approx 1 second If you hear a signal the device is working properly and can be
2. fastened The test signal 3 beeps sounds 4 times in total and the integrated LED flashes too 29 Putting into operation Alternatively you can use the RM test spray available from ABUS to test the wireless smoke detector If the RM test spray enters the detection chamber an alarm should sound so that you can test whether the wireless smoke detector is working properly After each teaching process and test alarm the devices require a 10 minute calibration period in order to exchange enough data packets Please do not initiate a test alarm during this time Networking the wireless smoke detectors Please note do not network another model of wireless smoke detector with this one This may lead to improper functioning and it cannot be guaranteed that the device will operate problem free If the test mode on one detector in a network is activated all other networked detectors will produce a signal too If one of the detectors in the network detects an alarm all other detectors in the network will raise the alarm If the battery in one detector is low this will be indicated directly by the affected detector In addition this will also be indicated by all networked detectors every 4 hours by 2 beeps and a flashing LED Networking the detectors recommended before installation You will require at least two RM40 Li wireless smoke detectors to be able to create a wireless detector network A maximum of 32 detectors c
3. instructions in this manual In the event of a warranty claim the original receipt with the date of purchase and a short description of the problem must be supplied along with the wireless smoke detector If you discover a defect on your wireless smoke detector which existed at the time of purchase contact your dealer directly within the first two years Declaration of conformity ABUS August Bremicker S hne KG Altenhofer Weg 25 58300 Wetter hereby declares that the RM40Li complies with the basic requirements and other relevant terms of the 1999 5 EG For further information on the CE declaration or to view the CE decla ration please get in touch with ABUS August Bremicker S hne KG Kunden servicecenter Altenhofer Weg 25 58300 Wetter Declaration of performance 201340 RM40Li This smoke detector has been tested and certified as a construction product in accordance with Regulation EU 305 2011 It has been manufactured subject to monitoring by regular and independent inspections for unchanges in compliance with legal and normative requirements The respective declaration of performance can be found at www abus com 38 Note 39 Subject to technical alterations No liability for mistakes and printing errors ABUS D 58292 Wetter Germany www abus com ABUS 07 2013
4. second counts there is no time to get dressed or gather valuable belongings Use the emergency escape routes Warn your fellow residents and make sure they also leave especially children and people with impaired hearing Do not open doors without first checking the surface Do not open a door if it is hot or you see smoke under it Use an alternative escape route If the surface is cool push against it with your shoulder slightly open it and be prepared to close it again if there is heat smoke or fire behind it f there is smoke in the air keep close to the floor and breathe through a damp cloth if possible Close the doors after leaving the room Once you have left the building go to the agreed assembly point and do not go back inside Call the fire brigade from outside the burning building Notify the fire brigade of the situation inside the building What to do if there is a false alarm A false alarm can occur due to very high air humidity the build up of smoke whilst cooking or a large build up of dust for example If the alarm sounds first get yourself to safety If you are certain that it is a false alarm you can mute the alarm tone by pressing the test button The alarm will continue to be indicated optically by the flashing LED The smoke detector will switch off automatically once the smoke particles have left the smoke chamber inside the detector 27 Putting into operation For recommended installa
5. RM4OLi Wireless Smoke alarm devices Security Tech Germany User manual Wireless Smoke alarm devices cE 07350021145 EN146042005 AC2008 6212035 Please read carefully through this instruction for use before starting up Smoke detectors help save lives Please keep save this instruction for use Device description Device description Contents Device descripti Okeere fe screens manne le sr nee aa nent 22 Safety InformatiOn 55555sc66eperosdsomameneneresononcenendennensehennenente esse 24 Putting intooperatiOi esasen Enee aar E ENNES seeds scines 27 Cleaningand disposal 45 55e ne tienne Sai 34 Device description see diagram Item Name Comment 1 Sound outlet The status lamp is under the cover on the right o CED sim Site beneath the logo and shines through it 3 Battery compartment 4 Detector base With mounting holes Press the lower section of the housing cover 5 Test button to the actuate the test button This button also funtions as the mute button for the alarm tone Function and features Smoke detection Photoelectric reflection Sound level At least 85 dB at a distance of 3 metres Optical alarm display LED flashes every 30 seconds or twice a second in the event of an alarm Temperature range 0 C to 40 C Humidity 0 to 90 23 Device description Safety information 1x 9 V alkali blick battery Max 40 mA Only approved for indoor use 868 Mhz Up to 30
6. a dry cloth Do not charge normal batteries heat them up or throw them into naked flames they may explode Important information on disposing of batteries Your product uses batteries which are subject to the European directive 2006 66 EC and may not be disposed of with domestic waste Find out about the regulations for the separate collection of batteries which apply in your country Proper disposal of batteries helps prevent harm to health and the environment Batteries that contain harmful chemicals are labelled with these signs Pb battery contains lead K Cd battery contains cadmium r Hg battery contains mercury E Guarantee ABUS products are designed and manufactured with the greatest care and tested according to the applicable regulations The warranty only covers defects caused by material or manufacturing errors that occurred before the product was purchased If there are demonstrable material or manufacturing errors the wireless smoke detector will be repaired or replaced at the warrantor s discretion In such cases the warranty ends when the original two year warranty period expires All further claims are expressly rejected The warranty does not cover the batteries supplied 37 Cleaning and disposal ABUS will not be held liable for defects and damage caused by external influences e g transport use of force operating errors inappropriate use normal wear and tear or failure to observe the
7. an be networked Due to the network connection the distance between individual detectors must be a maximum of 30 m The wireless range can be negatively influenced by the structural surroundings The RM4OLi detectors can be cascaded meaning that the detectors are not connected in one direction only so the alarm signal can be transmitted from the first to the last in a chain 30 Putting into operation This means that when a detector receives an alarm signal it forwards the signal on to the detectors it is connected to Note To assemble according to VdS the delay from the triggering sensor to the last connected sensor must not take more than 30 seconds For correct assembly make absolutely sure that this requirement is adhered to 1 Press the test button on the detector for approx 2 seconds until the LED flashes slowly roughly once a second The detector is now in addressing mode 31 Putting into operation 2 Press the test button on the second detector for approx 2 seconds to set this detector in addressing mode too 3 The detectors exit addressing mode automatically after 60 seconds 4 The addressing process can take up to 60 seconds When the detectors have been successfully trained the LED on both detectors lights up for around 5 seconds after which the detectors exit addressing mode If this was not successful the detector will return to standard mode automatically after 60 seconds If you wish to co
8. es Do not use chemicals Do not use flammable liquids for cleaning Information on the EU directive on waste electrical and electronic equipment To protect the environment do not dispose of the device with domestic waste at the end of its service life It can be disposed of at one of the appropriate collection points in your country Please obey your local regulations when disposing of material Dispose of the device in accordance with EU directive 2002 96 EC WEEE Waste Electrical and Electronic Equipment If you have any questions please contact the department of your local authority which is responsible for waste disposal Used equipment can be disposed of for example by your local or municipal authority the local waste disposal company or mes your dealer Information on handling batteries Make sure that batteries are kept away from small children Children may put batteries in their mouths and swallow them This can cause serious harm to their health If this happens consult a doctor immediately Do not charge normal batteries heat them up or throw them into naked flames they may explode Change low batteries in good time Always change all the batteries at the same time and use batteries of the same type 36 Cleaning and disposal Important Leaky or damaged batteries can cause chemical burns on contact with the skin In this case wear protective gloves Clean the battery compartment with
9. m Up to 32 detectors Up to 2 years Approx 30 days before discharge 35 mm 102 mm EN 14604 2005 VdS 3515 The manufacturer reserves the right to make technical modifications at any time Scope of delivery ABUS RM4OLi wireless smoke detector incl battery This user manual Installation material N Warning Indicates risk of injury or health hazards caused by A Warning Indicates risk of injury or health hazards i electrical voltage DAW Important Indicates possible damage to the device accessories 24 Safety information i Note Indicates important information Warning The wireless smoke detector does not detect gas steam heat or fire flames Detectors with special sensors are required for this People with hearing impairments may not be able to hear the alarm Special alarms with visible signalisation are available for such cases Wireless smoke detectors help save lives Therefore for safety s sake you should regularly test the battery and the operation of the detector For day to day use remember that the wireless smoke detector cannot prevent fires but simply provides signalisation in the event of one For your own safety please replace smoke detectors every ten years at the latest Very high electromagnetic radiation can cause malfunctions Therefore do not install the detector near strong magnets or devices which produce electromagnetic radiation The wireless smoke detector works
10. nnect several detectors together you will need to define a central detector with which you can connect the other detectors fl Proceed with points 1 to 4 as described to connect the detectors in a network The detectors will exchange their addressing data with another G Reset default factory settings separate network connections In order to reset the smoke detectors to the default factory settings Press the test button and hold it down After approx 2 seconds the LED will flash once a second After another 5 seconds the LED will flash more frequently approx twice a second Now let go of the button If a short beep is heard the procedure was successful All network connections between the detectors have then been separated Muting the detector If an alarm has been triggered the wireless smoke detector can be muted by pressing the test button In the case of networked detectors the mute button on the activated detector can also silence the alarm of the other networked detectors 32 test button has been pressed The mute remains active until the alarm is automati Putting into operation Please note that in all other cases the muting only applies to the detector whose cally reset See the following table for differences in the signal when the detector is muted Audible and visual signals Mode Standby Testing Smoke chamber fault Restforing the factory settings Fault in smoke chambe
11. operation we recommend using the following high quality lithium batteries Lithium EVE CR9V P 34 Cleaning and disposal The lifetime of the battery can be negatively affected by frequent alarms dirt large variations in the temperature or similar environmental influences After changing the battery the low battery warning may continue for a further 10 minutes due to the nature of the network Check the functionality after testing the battery Alarms and error signals When the alarm threshold is exceeded a loud alarm sounds The alarm continues sounding as long as there is smoke in the detection chamber The alarm is only switched off when there is no more smoke in the detection chamber Note Your device requires no maintenance Protect the device from dust dirt and moisture Cleaning Dusty detectors must be cleaned You can clean dust from the air vents of the detector using a vacuum cleaner or compressed air If necessary you can remove the dust with a brush When changing the battery carefully clean the detection chamber in the wireless smoke detector with a vacuum cleaner to remove any dust or dirt You can clean the surface using a cloth slightly dampened in soapy water 35 Cleaning and disposal Important Do not allow water to penetrate inside the device Do not clean the device in a dishwasher Do not use sharp pointed abrasive or corrosive cleaning materials or hard brush
12. optically by measuring smoke particles that penetrate into its measurement chamber When the alarm threshold is exceeded a loud alarm sounds The alarm is switched off as soon as there is no more smoke in the measuring chamber Monitoring area 40 m Battery operated 1x 9 V battery within a room Automatic battery state monitoring Optical LED indicator lamp and acoustic alarm Simple installation 25 Safety information Warning Observe the following instructions to prevent any failure of the device Do not cover the device Do not paint over the device or cover it with wallpaper Never open the device or attempt to repair it as its function can then no longer be guaranteed Failure to observe this instruction will invalidate the warranty Do not use the device if it has been dropped or damaged in any other way f you pass on the device to someone else you must include this user manual Before operation Warning Keep children away from the packaging there is a risk of suffocation Remove all packaging material before using the device Intended use Only use the device for the purpose which it was designed and built for Any other use is considered inappropriate This device may only be used for the following purpose s Detecting fire smoke in private households 26 Safety information Putting into operation What to do when you hear the alarm Leave the premises immediately Every
13. r Indivisual operation Alarm Muting the detector Low battery Audible 3 beeps 4 times Beeps once every 30 seconds Short beep Beeps once every 30 seconds Beeps once a second Beeps once every 30 seconds Visual LED flashes every 30 seconds LED flashes twice a second LED flashes twice a second LED flashes twice LED flashes every 30 seconds LED flashes twice a second LED flashes once a second LED flashes every 30 seconds 33 Notes Acoustically and visually out of sync Acoustically and visually in sync Putting into operation Cleaning and disposal Mode Audible Visual Notes Networked detector Beeps once LED flashes twices Alen a second a second Muting the detector Low battery Beeps twice every Flashes twice every Acoustically and 4 hours 4 hours visually in sync Addressing Sais Addressing 3 LED lights up for successful 5 seconds Replacing the battery Ifthe battery is low the wireless smoke detector beeps twice a minute for up to 30 days to remind you to replace the battery You must change this battery when you hear this signal Even so the wireless smoke detector remains functional in this condition You must test the wireless smoke detector each time you change the battery Carry out the test as detailed above to check if the functioning and the network connection can still be guaranteed Note To ensure a long service life and reliable
14. tion locations see diagram Position the wireless smoke detector directly on the ceiling in the centre of the room Priority rooms living rooms bedrooms and children s playrooms Ifyou have more than one bedroom each one should be fitted with a wireless smoke detector To monitor corridors you should also fit wireless smoke detectors there because stairwells are particularly susceptible to fires due to the chimney effect Long corridors might require several smoke detectors When fitting on the ceiling make sure that the smoke detectors are at least 15 cm from the side walls and 50 cm from the corners Warning Avoid the following locations to prevent malfunctions of the wireless smoke detector Places where expected temperature variations are greater than the ambient operating temperature 0 C to 40 C Places where draughts can keep smoke away from the detector such as near windows doors or ventilation shafts Places where vapour increased air humidity or exhaust fumes may trigger false alarms e g in kitchens bathrooms or garages Places where dust or dirt could impair the function of the smoke detector The highest point in rooms with gable ceilings The distance to the highest point of the gable should be at least 30 cm 28 Putting into operation For installation and attachment see diagram Warning When marking out the drill holes make sure there are no electrical wires or cables