1. Digital channels MSO models add 16 digital channels to the corresponding DPO model MSO3012 and MSO3014 and MS03032 and MS03034 and DPO3052 MS03054 and DPO3012 DPO3014 DPO3032 DPO3034 DPO3054 Analog channels 2 4 2 4 2 4 Analog bandwidth 3dB 100 MHz 100 MHz 300 MHz 300 MHz 500 MHz 500 MHz Calculated rise time at 5 mv div 3 5 ns 3 5 NS 1 17 ns 1 17 ns 700 ps 700 ps typical Sample rate analog channels 2 0 GS s 2 0 GS s 2 0 GS s 2 0 GS s 2 0 GS s 2 0 GS s Record length 5 M points 5 M points 5 M points 5 M points 5 M points 5 M points Vertical system analog channels Hardware bandwidth limits 2300 MHz models 100 MHz models Input coupling Input impedance Input sensitivity range 1MQ 75 Q 50 Q Vertical resolution Maximum input voltage 1 MQ 75 Q 50 Q DC gain accuracy Channel to channel isolation Offset range 10 www tektronix com 20 MHz and 150 MHz 20 MHz AC DC GND 1MQ 41 75 Q 1 500 1 1 mV div to 10 V div 1 mV div to 1 V div 8 bits 11 bits with Hi Res 300 Vems with peaks lt 450 V 5 Vems with peaks lt 20 V 1 5 for 5 mV div and above 2 0 for 2 mV div 2 5 for 1 mV div Any two channels at equal vertical scale 2100 1 at lt 100 MHz and 230 1 at gt 100 MHz up to the rated bandwidth Volts div setting Offset range 1 MQ input 50 Q and 75 Q input 1 mV div to 99 5 mV div 1 V 1 V 100 mV div to 995 mV div 10 V 5 V 1 V div to 10
2. A11 Opt A12 Opt A99 18 www tektronix com North America power plug 115 V 60 Hz Universal Euro power plug 220 V 50 Hz United Kingdom power plug 240 V 50 Hz Australia power plug 240 V 50 Hz Switzerland power plug 220 V 50 Hz Japan power plug 100 V 110 120 V 60 Hz China power plug 50 Hz India power plug 50 Hz Brazil power plug 60 Hz No power cord MSO3000 Series and DPO3000 Series Mixed Signal Oscilloscopes Language options Opt LO English manual Opt L1 French manual Opt L2 Italian manual Opt L3 German manual Opt L4 Spanish manual Opt L5 Japanese manual Opt L6 Portuguese manual Opt L7 Simplified Chinese manual Opt L8 Traditional Chinese manual Opt L9 Korean manual Opt L10 Russian manual Opt L99 No manual Language options include translated front panel overlay for the selected language s Service options Opt CA1 Single Calibration or Functional Verification Opt D1 Calibration Data Report Opt R5 Repair Service 5 Years including warranty Opt SILV400 Standard warranty extended to 5 years Probes and accessories are not covered by the oscilloscope warranty and service offerings Refer to the datasheet of each probe and accessory model for its unique warranty and calibration terms Recommended accessories Probes TAP1500 1 5 GHz TekVPI active voltage probe TAP1500X2 Bundle of two 1 5 GHz active probes single ended with TekVPI interface TCP0030 120 MHz TekVPI 30
3. Parity individually Data Word user specified 16 bit data value Error Sync Parity Manchester Non contiguous data Idle Time minimum time selectable from 2 us to 100 us maximum time selectable from 2 us to 100 us trigger on lt minimum gt maximum inside range outside range RT Address can be further specified to trigger on lt gt lt 2 a particular value or inside or outside of a range Trigger on Word Select Frame Sync or Data Data can be further specified to trigger on lt lt gt 2 a specific data value or inside or outside of a range Maximum data rate for I S LJ RJ is 12 5 Mb s Maximum data rate for TDM is 25 Mb s Trigger on a parallel bus data value Parallel bus can be from 1 to 16 bits from the digital channels plus 2 or 4 bits from the analog channels in size Binary and Hex radices are supported Acquire sampled values Captures glitches as narrow as 2 ns at all sweep speeds From 2 to 512 waveforms included in average Min max envelope reflecting Peak Detect data over multiple acquisitions Real time boxcar averaging reduces random noise and increases vertical resolution Scrolls waveforms right to left across the screen at sweep speeds slower than or equal to 40 ms div Waveform and Screen 29 of which up to four can be displayed on screen at any one time Measurements include Period Frequency Delay Rise Time Fall Time Positive Duty Cycle Negative Duty Cycle Positive
4. V div 100 V 5 V MSO3000 Series and DPO3000 Series Mixed Signal Oscilloscopes Vertical system digital channels Thresholds Threshold selections User defined threshold range Maximum input voltage Threshold accuracy Maximum input dynamic range Minimum voltage swing Input resistance Probe loading Vertical resolution Threshold per set of 8 channels TTL CMOS ECL PECL User defined 15 V to 25 V 20 V to 30 V 100 mV 3 of threshold setting 50 Vp p threshold setting dependent 500 mV 101 kQ 8 pF 1 bit Horizontal system analog channels Maximum duration of time captured at highest sample rate all channels Seconds division range Time base delay time range Channel to channel deskew range Time base accuracy 2 ms 1 ns div to 1000 s div 10 divisions to 5000 s 100 ns 10 ppm over any 21 ms interval Horizontal system digital channels Seconds division range Maximum record length main all channels Maximum sample rate MagniVu all channels Maximum record length MagniVu all channels Minimum detectible pulse width Channel to channel skew 1 ns div to 1000 s div 5 M points 8 25 GS s 121 2 ps resolution 10 k points centered on the trigger 2 0 ns 500 ps typical digital channel to digital channel only This is the propagation path skew and ignores skew contributions due to bandpass distortion threshold inaccuracies see Threshold accuracy and samp
5. decode Event table Search Order product Embedded 2c E 5 E m DPO3EMBD SPI E E E E DPO3EMBD Computer RS232 422 485 UART m E E E DPO3COMP Automotive CAN E E E E DPO3AUTO LIN E E E E DPO3AUTO FlexRay E E E E DPO3FLEX Military and aerospace MIL STD 1553 E E E E DPO3AERO Audio 2S E E E E DPO3AUDIO LJ RJ E E E E DPO3AUDIO TDM E E E m DPO3AUDIO Event table Power analysis optional In addition to seeing decoded packet data on the bus waveform itself you Ever increasing consumer demand for longer battery life devices and for can view all captured packets in a tabular view much like you would see in green solutions that consume less power require power supply designers to a software listing Packets are time stamped and listed consecutively with characterize and minimize switching losses to improve efficiency In columns for each component Address Data etc You can save the event addition the supply s power levels output purity and harmonic feedback table data in csv format into the power line must be characterized to comply with national and Stop regional power quality standards Historically making these and many Bie CNUE GEER eae CRC Missing Ack Event Table other power measurements on an oscilloscope has been a long manual 519 4 4269 6C6C i i r i i i 1597EEB2 AE4F FFF1 0272 DF6B and tedious process The optional power analysis tools greatly simplify D ieee these tasks enabling quick and accurate analysis of power quality eee E E s
6. di dt measurements Waveform math Arithmetic Math functions FFT Advanced math Software NI LabVIEW SignalExpress Tektronix Edition OpenChoice Desktop IVI driver e Scope Web based remote control Display system Display type Display resolution Waveform styles Graticules Format Maximum waveform capture rate 14 www tektronix com Graphical display and mask testing of switching device safe operating area measurements Cursor measurements of slew rate Add subtract multiply and divide waveforms Integrate Differentiate FFT Spectral magnitude Set FFT Vertical Scale to Linear RMS or dBV RMS and FFT Window to Rectangular Hamming Hanning or Blackman Harris Define extensive algebraic expressions including waveforms reference waveforms math functions FFT Intg Diff Log Exp Sart Sine Cosine Tangent scalars up to two user adjustable variables and results of parametric measurements Period Freq Delay Rise Fall PosWidth NegWidth BurstWidth Phase PosDutyCycle NegDutyCycle PosOverShoot NegOverShoot PeakPeak Amplitude RMS CycleRMS High Low Max Min Mean CycleMean Area CycleArea and trend plots e g Intg Ch1 Mean Ch1 x 1 414 x VAR A fully interactive measurement software environment optimized for your Tektronix oscilloscope enables you to instantly acquire generate analyze compare import and save measurement data and signals using an intuitive drag and drop
7. port Auxiliary input Probe compensator output voltage and frequency Amplitude Frequency Trigger out Kensington style lock Power source Power source voltage Power source frequency Power consumption Optional TekVPI external power supply Output voltage Output current Power consumption Physical characteristics Dimensions Weight Rackmount configuration Cooling clearance MSO3000 Series and DPO3000 Series Mixed Signal Oscilloscopes Supports USB mass storage devices printers and keyboards One port available on rear panel and one on front panel RJ 45 connector supports 10 100BASE T Available as an optional accessory that connects to the USB Device and USB Host port with the TEK USB 488 GPIB to USB Adapter The control interface is incorporated in the instrument user interface DB 15 female connector connect to show the oscilloscope display on an external monitor or projector SVGA resolution Front panel BNC connector Input Impedance 1 MQ Max input 300 Vays CAT II with peaks lt 425 V Front panel pins 0to2 5V 1 kHz Rear panel BNC connector provides a negative polarity pulse when the oscilloscope triggers Rear panel security slot connects to standard Kensington style lock 85 to 265 V 10 45 to 440 Hz 85 to 265 V 120 W maximum 12V 5A 50 W mm in Height 203 2 8 Width 416 6 16 4 Depth 147 3 5 8 kg Ib Net 4 17 9 2 Shipping 8 62 1
8. they form a group I Stor SES E Digital Channel Vertical Position 3 44 div Select 1 60 V aon b 1 60V Apply Preset i it Ri Rak Le a MSN Al id dd Ra a a r Al all RelA Ll Me Roh E LAR La Mea a Rl lA a a a ta 1 40 V 1 40 V 1 60 Y 1 80 V 2 00 V 2 20 V 2 40 V D BEBE REREE kez various f250MS7 s 10k points f 2 44V 7 i Timing Resolution 4 00ns _ Tae ME eroe ce O o o With color coded digital waveform display groups are created by simply placing digital channels together on the screen allowing digital channels to be moved as a group You can set threshold values for each channel enabling support for up to 16 different logic families Once a group is formed you can position all the channels contained in that group collectively This greatly reduces the normal setup time associated with positioning channels individually www tektronix com 5 Datasheet MagniVu high speed acquisition The main digital acquisition mode on the MSO3000 Series will capture up to 5 Mpoints at 500 MS s 2 ns resolution In addition to the main record the MSO3000 provides an ultra high resolution record called MagniVu which acquires 10 000 points at up to 8 25 GS s 121 2 ps resolution Both main and MagniVu waveforms are acquired on every trigger and can be switched between in the display at any time running or stopped MagniVu provides significantly finer timing resolu
9. 000 Rackmount kit Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar PIB Product s complies with IEEE Standard 488 1 1987 RS 232 C and with Tektronix Standard Codes and Formats IEEE 488 4 20 www tektronix com Required when total oscilloscope probe power usage exceeds 20 W Power cord not included MSO3000 Series and DPO3000 Series Mixed Signal Oscilloscopes www tektronix com 21 Datasheet ASEAN Australasia 65 6356 3900 Austria 00800 2255 4835 Balkans Israel South Africa and other ISE Countries 41 52 675 3777 Belgium 00800 2255 4835 Brazil 55 11 3759 7627 Canada 1 800 833 9200 Central East Europe and the Baltics 41 52 675 3777 Central Europe amp Greece 41 52 675 3777 Denmark 45 80 88 1401 Finland 41 52 675 3777 France 00800 2255 4835 Germany 00800 2255 4835 Hong Kong 400 820 5835 India 000 800 650 1835 Italy 00800 2255 4835 Japan 81 3 6714 3010 Luxembourg 41 52 675 3777 Mexico Central South America amp Caribbean 52 55 56 04 50 90 Middle East Asia and North Africa 41 52 675 3777 The Netherlands 00800 2255 4835 Norway 800 16098 People s Republic of China 400 820 5835 Poland 41 52 675 3777 Portugal 80 08 12370 Republic of Korea 001 800 8255 2835 Russia amp CIS 7 495 6647564 South Africa 41 52 675 3777 Spain 00800 2255 4835 Sweden 00800 2255 4835 Switzerland 00800 2255 4835 Taiwan 886 2 2722 9622 United Kingdom amp Ireland 00800 2255 4835 US
10. 9 5U 2 in 51 mm required on left side and rear of instrument 2 Required when total oscilloscope probe power usage exceeds 20 W www tektronix com 15 Datasheet EMC environment and safety Temperature Operating Nonoperating Humidity Operating Nonoperating Altitude Operating Nonoperating Random vibration Operating Nonoperating Regulatory Electromagnetic compatibility Safety 0 C to 50 C 32 F to 122 F 40 C to 71 C 40 F to 160 F High 30 C to 50 C 5 to 45 relative humidity Low 0 C to 30 C 5 to 95 relative humidity High 30 C to 50 C 5 to 45 relative humidity Low 0 C to 30 C 5 to 95 relative humidity 3 000 meters 9 843 feet 12 000 meters 39 370 feet 0 31 Grys from 5 to 500 Hz 10 minutes each axis 3 axes 30 minutes total 2 46 Grys from 5 to 500 Hz 10 minutes each axis 3 axes 30 minutes total EC Council Directive 2004 108 EC UL61010 1 2004 CAN CSA C22 2 No 61010 1 2004 Low Voltage Directive 2006 95 EC and EN61010 1 2001 IEC 61010 1 2001 ANSI 61010 1 2004 ISA 82 02 01 Ordering information DPO3000 and MSO3000 models DPO3012 DPO3014 DP03032 DP03034 DPO3052 DPO3054 MSO3012 MSO3014 MS03032 MS03034 MS03054 16 www tektronix com 100 MHz 2 5 GS s 5 M record length 2 channel digital phosphor oscilloscope 100 MHz 2 5 GS s 5 M record length 4 channel digital phosphor oscilloscope 300 MHz 2 5 GS s 5 M record length 2 chann
11. A 1 800 833 9200 European toll free number If not accessible call 41 52 675 3777 Updated 10 April 2013 For Further Information Tektronix maintains a comprehensive constantly expanding collection of application notes technical briefs and other resources to help engineers working on the cutting edge of technology Please visit www tektronix com Copyright Tektronix Inc All rights reserved Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supersedes that in all previously published material Specification and price SA change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc All other trade names referenced are the service marks trademarks or registered trademarks of their respective companies as fay 16 Jul 2013 3GW 21364 11 www tektronix com Tektronix S
12. Ampere AC DC current probe TCP0150 20 MHz TekVPI 150 Ampere AC DC current probe TCPA300 400 Current measurement systems amplifier TDP0500 500 MHz TekVPI differential voltage probe with 42 V differential input voltage TDP1000 1 GHz TekVPI differential voltage probe with 42 V differential input voltage TMDP0200 750 V 200 MHz high voltage differential probe THDP0200 1 5 kV 200 MHz high voltage differential probe THDP0100 6 kV 100 MHz high voltage differential probe P5100A 2 5 kV 100X high voltage passive probe 3 Requires TekVPI to TekProbe BNC adapter TPA BNC www tektronix com 19 Datasheet P5200 P5205 P5210 ADA400A NEX HD2HEADER Accessories 071 2667 xx TPA BNC TEK DPG 067 1686 xx 119 7465 xx SIGEXPTE FPGAView xx TEK USB 488 ACD4000 HCTEK4321 RMD3000 1 3 kV 25 MHz high voltage differential probe 1 3 kV 100 MHz high voltage differential probe 5 6 kV 50 MHz high voltage differential probe 100X 10X 1X 0 1X high gain differential amplifier Mictor connector breakout to 0 1 in header pins Service manual English only TekVPI to TekProbe BNC adapter TekVPI Deskew pulse generator signal source Power measurement deskew and calibration fixture TekVPI external power supply 4 National Instruments LabVIEW SignalExpress Tektronix Edition software full version MSO support for Altera and Xilinx FPGAs GPIB to USB adapter Soft transit case Hard transit case requires ACD4
13. O3000 Series and DPO3000 Series Mixed Signal Oscilloscopes TekVPI probe interface The TekVPI probe interface sets the standard for ease of use in probing In addition to the secure reliable connection that the interface provides TekVPI probes feature status indicators and controls as well as a probe menu button right on the comp box itself This button brings up a probe menu on the oscilloscope display with all relevant settings and controls for the probe The TekVPI interface enables direct attachment of current probes without requiring a separate power supply TekVPI probes can be controlled remotely through USB GPIB or LAN enabling more versatile solutions in ATE environments TekVPI probe interface simplifies connecting your probes to the oscilloscope Extended analysis Exporting data and measurements is as simple as connecting a USB cable from the oscilloscope to your PC Key software applications NI LabVIEW SignalExpress Tektronix Edition LE OpenChoice Desktop and Microsoft Excel and Word toolbars are included standard with each oscilloscope to enable fast and easy direct communication with your Windows PC NI LabVIEW SignalExpress Tektronix Edition LE enables you to instantly acquire generate analyze compare import and save measurement data and signals using an intuitive drag and drop user interface that does not require any programming The optional Professional Version offers over 200 built in function
14. Pulse Width Negative Pulse Width Burst Width Phase Positive Overshoot Negative Overshoot Peak to Peak Amplitude High Low Max Min Mean Cycle Mean RMS Cycle RMS Positive Pulse Count Negative Pulse Count Rising Edge Count Falling Edge Count Area and Cycle Area Mean Min Max Standard Deviation User definable reference levels for automatic measurements can be specified in either percent or units Isolate the specific occurrence within an acquisition to take measurements on using either the screen or waveform cursors Power measurements optional Power Quality Measurements Switching loss measurements Power loss Energy loss Harmonics Ripple measurements Modulation Analysis Vems Vcrest Factor Frequency lps Icrest Factor True Power Apparent Power Reactive Power Power Factor Phase Angle Ton To Conduction Total Ton To Conduction Total THD F THD R RMS measurements Graphical and table displays of harmonics Test to IEC61000 3 2 Class A and MIL STD 1399 Section 300A VRipple and lRipple Graphical display of Pulse Width Pulse Width Period Frequency Duty Cycle and Duty Cycle modulation types 1 Trigger selection of Command Word will trigger on Command and ambiguous Command Status words Trigger selection of Status Word will trigger on Status and ambiguous Command Status words www tektronix com 13 Datasheet Power measurements optional Safe operating area dV dt and
15. Tektronix Mixed Signal Oscilloscopes MSO3000 Series DPO3000 Series Datasheet aC Oj Ompa fs FR oO With the MSO DPO3000 mixed signal oscilloscope series you can analyze up to 20 analog and digital signals with a single instrument to quickly find and diagnose problems in complex designs Bandwidths up to 500 MHz and a minimum of 5x oversampling on all channels ensure you have the performance you need for many of today s mainstream applications To capture long windows of signal activity while maintaining fine timing resolution the MSO DPO3000 offers a deep record length of 5 M points standard on all channels Key performance specifications 500 300 100 MHz bandwidth models Bandwidth is upgradable up to 500 MHz 2 and 4 analog channel models 2 5 GS s sample rate on all channels 9mega point record length on all channels gt 50 000 wim s maximum waveform capture rate Suite of advanced triggers Key features Wave Inspector Controls provide easy navigation and automated search of waveform data 29 automated measurements and FFT analysis for simplified waveform analysis 16 digital channels MSO series Mixed signal design and analysis MSO series Automated triggering decode and search on parallel buses Multichannel setup and hold triggering MagniVu high speed acquisition provides 121 2 ps fine timing resolution on digital channels Optional serial trigg
16. ansferred between an application module and an oscilloscope The license may be contained in the module allowing the module to be moved from one instrument to another Or the license can be contained in the oscilloscope allowing the module to be removed and stored for safekeeping Transferring the license to an oscilloscope and removing the module permits the use of more than 4 applications simultaneously DPO3AERO Aerospace Serial Triggering and Analysis Module Enables triggering on packet level information on MIL STD 1553 buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Signal Inputs Any Ch1 Ch4 Math Ref1 Ref4 Recommended Probing Differential or single ended only one single ended signal required DPO3AUDIO Audio Serial Triggering and Analysis Module Enables triggering on packet level information on I S Left Justified Right Justified TDM and custom audio buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Signal Inputs Any Ch1 Ch4 and any DO D15 on MSO models Recommended Probing Single ended DPO3AUTO Automotive Serial Triggering and Analysis Module Enables triggering on packet level information on CAN bus and LIN bus as well as analytical tools such as digital views of the signal bus vi
17. ata Identifier and Data End of Frame Missing ACK or Bit Stuffing Error on CAN signals up to 1 Mb s Data can be further specified to trigger on lt lt gt 2 or a Specific data value User adjustable sample point is set to 50 by default LIN optional Trigger on Sync Identifier Data Identifier and Data Wakeup Frame Sleep Frame Errors such as Sync Parity or Checksum Errors up to 100 kb s by LIN definition 20 kb s FlexRay optional Trigger on Start of Frame Type of Frame Normal Payload Null Sync Startup Identifier Cycle Count Complete Header Field Data Identifier and Data End of Frame or Errors such as Header CRC Trailer CRC Null Frame Sync Frame or Startup Frame Errors up to 100 Mb s Trigger system MIL STD 1553 optional I2S LJ RJ TDM optional Parallel available on MSO models only Acquisition system Acquisition Modes Sample Peak Detect Averaging Envelope Hi Res Roll Waveform measurements Cursors Automatic measurements Measurement statistics Reference levels Gating MSO3000 Series and DPO3000 Series Mixed Signal Oscilloscopes Trigger on Sync Word Type Command Status Data Command Word set RT Address T R Sub address Mode Data Word Count Mode Code and Parity individually Status Word set RT Address Message Error Instrumentation Service Request Bit Broadcast Command Received Busy Subsystem Flag Dynamic Bus Control Acceptance DBCA Terminal Flag and
18. e Verifying that your prototype s performance matches simulations and meets the project s design goals requires analyzing its behavior Tasks can range from simple checks of rise times and pulse widths to sophisticated power loss analysis and investigation of noise sources The oscilloscope offers a comprehensive set of integrated analysis tools including waveform and screen based cursors automated measurements advanced waveform math including arbitrary equation editing FFT analysis and trend plots for visually determining how a measurement is changing over time Specialized application support for serial bus analysis power supply design and video design and development is also available For extended analysis National Instrument s LabVIEW SignalExpress Tektronix Edition provides over 200 built in functions including time and frequency domain analysis limit testing data logging and customizable reports 2 50GS s 100k points 20 0ns I AO 1 72V Analyze FFT analysis of a pulsed signal A comprehensive set of integrated analysis tools speeds verification of your design s performance Wave Inspector navigation and search With long record lengths a single acquisition can include thousands of screens of waveform data Wave Inspector the industry s best tool for navigation and search enables you to find events of interest in seconds Runt o Positive 1 60 Runt Occu Wave Inspector controls provide u
19. el digital phosphor oscilloscope 300 MHz 2 5 GS s 5 M record length 4 channel digital phosphor oscilloscope 500 MHz 2 5 GS s 5 M record length 2 channel digital phosphor oscilloscope 500 MHz 2 5 GS s 5 M record length 4 channel digital phosphor oscilloscope 100 MHz 2 5 GS s 5 M record length 2 16 channel mixed signal oscilloscope 100 MHz 2 5 GS s 5 M record length 4 16 channel mixed signal oscilloscope 300 MHz 2 5 GS s 5 M record length 2 16 channel mixed signal oscilloscope 300 MHz 2 5 GS s 5 M record length 4 16 channel mixed signal oscilloscope 500 MHz 2 5 GS s 5 M record length 4 16 channel mixed signal oscilloscope MSO3000 Series and DPO3000 Series Mixed Signal Oscilloscopes Standard accessories Probes P6139A 500 MHz 10x passive probe one per analog channel P6316 MSO models only 16 channel logic probe and accessory kit one per instrument Accessories Please specify power plug and manual language version when ordering 200 5052 xx Front cover 063 4104 xx Documentation CD 016 2008 xx Accessory pouch User manual Power cord OpenChoice Desktop software NI LabVIEW SignalExpress Tektronix Edition LE software Calibration certificate documenting traceability to National Metrology Institute s and IS09001 quality system registration Warranty Three year warranty covering all parts and labor excluding probes Application modules Application modules have licenses which can be tr
20. ering and analysis automated serial triggering decode and search options for I2C SPI CAN LIN RS 232 422 485 UART and S LJ RJ TDM TekVPI probe interface supports active differential and current probes for automatic scaling and units Qin 229 mm WVGA widescreen color display Small footprint and lightweight Only 5 8 in 147 mm deep and 9 Ib 4 kg Connectivity USB 2 0 host port on both the front panel and rear panel for quick and easy data storage printing and connecting a USB keyboard USB 2 0 device port on the rear panel for easy connection to a PC or direct printing to a PictBridge compatible printer Integrated 10 100 Ethernet port for network connection and video out port to export the oscilloscope display to a monitor or projector Optional application support Power analysis HDTV and custom video analysis www tektronix com 1 Datasheet Feature rich tools for debugging mixed signal designs With Wave Inspector controls for rapid waveform navigation automated serial and parallel bus analysis and automated power analysis your Tektronix oscilloscope provides the feature rich tools you need to simplify and speed debug of your complex design Comprehensive features speed every stage of debug These oscilloscopes offer a robust set of features to speed every stage of debugging your design from quickly discovering an anomaly and capturing it to searching your wavef
21. ews packet decoding search tools and packet decode tables with time stamp information Signal Inputs LIN Any Ch1 Ch4 and any DO D15 on MSO models CAN Any Ch1 Ch4 and any DO D15 on MSO models single ended probing only Recommended Probing LIN Single ended CAN Single ended or differential www tektronix com 17 Datasheet DPO3COMP DPO3EMBD DPO3FLEX DPO3PWR DPO3VID Instrument options Bandwidth upgrades Computer Serial Triggering and Analysis Module Enables triggering on packet level information on RS 232 422 485 UART buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Signal Inputs Any Ch1 Ch4 and any DO D15 on MSO models single ended probing only Recommended Probing RS 232 UART Single ended RS 422 485 Differential Embedded Serial Triggering and Analysis Module Enables triggering on packet level information on C and SPI buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools and packet decode tables with time stamp information Only two wire SPI support available on DPO3012 DPO3032 and DPO3052 models Signal Inputs IC Any Ch1 Ch4 and any DO D15 on MSO models SPI Any Ch1 Ch4 and any DO D15 on MSO models Recommended Probing I2C SPI Single ended FlexRay Serial Triggering and Analysis Module Enab
22. he control the other way User marks Press the Set Mark front panel button to place one or more marks on the waveform Navigating between marks is as simple as pressing the Previous lt and Next buttons on the front panel Search marks The Search button allows you to automatically search through your long acquisition looking for user defined events All occurrences of the event are highlighted with search marks and are easily navigated to using the front panel Previous lt and Next buttons Search types include edge pulse width glitch timeout runt logic setup and hold rise fall time parallel bus and I C SPI CAN LIN FlexRay RS 232 422 485 UART MIL STD 1553 and 2S LJ RJ TDM packet content Search For Fee Number of C ED 2 40 0us 10 0MS s f 3 01V Bus Search events found 33 i LIM points Search Search Type Source Bus Search For identifier Data on Bus BR CAN Id amp Data OXXh 11h Search step 1 You define what you would like to find 4 www tektronix com ED bat CES ECCONE ios BYLCAN 2E QB s0omvy 2 20 048 Fee ieee 3 01 V Bus Search events found 33 1M points Search step 2 Wave Inspector automatically searches through the record and marks each event with a hollow white triangle You can then use the Previous and Next buttons to jump from one event to the next Digital phosphor technology Digital phosphor technology provides you w
23. ils to cross a second threshold before crossing the first again Logic Trigger when any logical pattern of channels goes false or stays true for specified period of time Any input can be used as a clock to look for the pattern on a clock edge Pattern AND OR NAND NOR specified for all input channels defined as High Low or Don t Care Setup and Hold Trigger on violations of both setup time and hold time between clock and data present on any of the analog and digital input channels Rise Fall Time Trigger on pulse edge rates that are faster or slower than specified Slope may be positive negative or either Video Trigger on all lines odd even or all fields on NTSC PAL and SECAM video signals Extended Video optional Trigger on 480p 60 576p 50 720p 30 720p 50 720p 60 8751 60 1080i 50 1080i 60 1080p 24 1080p 24sF 1080p 25 1080p 30 1080p 50 1080p 60 and custom bi level and tri level sync video standards I2C optional Trigger on Start Repeated Start Stop Missing ACK Address 7 or 10 bit Data or Address and Data on 1C buses up to 10 Mb s SPI optional Trigger on SS MOSI MISO or MOSI and MISO on SPI buses up to 10 0 Mb s RS 232 422 485 UART Trigger on Tx Start Bit Rx Start Bit Tx End of Packet Rx End of Packet Tx Data Rx Data Tx Parity Error and Rx Parity Error up optional to 10 Mb s CAN optional Trigger on Start of Frame Frame Type data remote error overload Identifier standard or extended D
24. ith fast insight into the real operation of your device Its fast waveform capture rate greater than 50 000 wfm s gives you a high probability of quickly seeing the infrequent problems common in digital systems runt pulses glitches timing issues and more Waveforms are superimposed with one another and waveform points that occur more frequently are intensified This quickly highlights the events that over time occur more often or in the case of infrequent anomalies occur less often You can choose infinite persistence or variable persistence determining how long the previous waveform acquisitions stay on screen This allows you to determine how often an anomaly is occurring Se 500mvV 3 Ti 4 00ns 5 00GS s In 10k points Digital phosphor technology enables greater than 50 000 wfms s waveform capture rate and real time intensity grading MSO3000 Series and DPO3000 Series Mixed Signal Oscilloscopes Mixed signal design and analysis MSO series The MSO models provide 16 digital channels which are tightly integrated into the oscilloscope s user interface This simplifies operation and makes it possible to solve mixed signal issues easily 11 20MH2_CLOCK tnt python aha ahii m Pedu 2ASTRO BE et ig i NV y COUNT6 COUNTS F counra 4 CINE 3 corte COUNT py COUNTO 9 CLOCK Parallel am I 07 I 08 5 00 V 100ns 5 00GS s Data 1M points D15 D0 Timing Resolutio
25. le binning see Digital channel timing resolution www tektronix com 11 Datasheet Trigger system Trigger modes Auto Normal and Single Trigger coupling DC AC HF reject attenuates gt 50 kHz LF reject attenuates lt 50 kHz noise reject reduces sensitivity Trigger holdoff range 20 ns to 8 s Trigger sensitivity typical Edge type DC coupled Trigger level ranges Any input channel Aux Input external trigger 12 www tektronix com Trigger Source Sensitivity Any input channel 0 50 div from DC to 50 MHz increasing to 1 div at oscilloscope bandwidth Aux input external trigger 200 mV from DC to 50 MHz increasing to 500 mV at 250 MHz Line Fixed 8 divisions from center of screen 8 divisions from 0 V when vertical LF reject trigger coupling is selected 8 V Line The line trigger level is fixed at about 50 of the line voltage Trigger types Edge Positive or negative slope on any channel or front panel auxiliary input Coupling includes DC AC HF reject LF reject and noise reject Sequence B trigger Trigger Delay by Time 8 ns to 8 s Or Trigger Delay by Events 1 to 9 999 999 events Pulse Width Trigger on width of positive or negative pulses that are gt lt or inside outside a specified period of time Timeout Trigger on an event which remains high low or either for a specified time period 4 ns to 8 s Runt Trigger on a pulse that crosses one threshold but fa
26. les triggering on packet level information on FlexRay buses as well as analytical tools such as digital views of the signal bus views packet decoding search tools packet decode tables with time stamp information Signal Inputs Any Ch1 Ch4 and any DO D15 on MSO models single ended probing only Recommended Probing Single ended or differential Power Analysis Module Enables quick and accurate analysis of power quality switching loss harmonics safe operating area SOA modulation ripple and slew rate dl dt dV dt HDTV and Custom nonstandard Video Triggering Module Bandwidth is fully upgradable up to 500 MHz on any MSO DPO3000 Series oscilloscope Instruments with serial numbers starting with C02 or B02 are upgraded with a software option key Instruments with serial numbers starting with C01 or B01 must be upgraded at an authorized Tektronix service center DPO3BW1T32 DPO3BW1T34 DPO3BW1T52 DPO3BW1T54 DPO3BW3T52 DPO3BW3T54 Bandwidth upgrade from 100 MHz to 300 MHz for an MSO DP03012 Bandwidth upgrade from 100 MHz to 300 MHz for an MSO DPO3014 Bandwidth upgrade from 100 MHz to 500 MHz for an MSO DPO3012 Bandwidth upgrade from 100 MHz to 500 MHz for an MSO DPO3014 Bandwidth upgrade from 300 MHz to 500 MHz for an MSO DPO3012 or an MSO DPO3032 Bandwidth upgrade from 300 MHz to 500 MHz for an MSO DPO3014 or an MSO DPO3034 Power cord and plug options Opt A0 Opt A1 Opt A2 Opt A3 Opt A5 Opt A6 Opt A10 Opt
27. n 2 00ns gt The MSO Series provides 16 integrated digital channels enabling you to view and analyze time correlated analog and digital signals Color coded digital waveform display This oscilloscope has redefined the way you view digital waveforms One common problem shared by both logic analyzers and mixed signal oscilloscopes is determining if data is a one or a zero when zoomed in far enough that the digital trace stays flat all the way across the display Color coded digital traces display ones in green and zeros in blue The multiple transition detection hardware shows you a white edge on the display when the system detects multiple transitions White edges indicate that more information is available by zooming in or acquiring at faster sampling rates In most cases zooming in will reveal the pulse that was not viewable with the previous settings If the white edge is still present after zooming in as far as possible this indicates that increasing the sample rate on the next acquisition will reveal higher frequency information than the previous settings could acquire Ti us 1 00GS75 j 110k points D15 D0 ie Timing Resolution 2 00ns iie White edges indicate additional information is available by zooming in As shown here zooming in on the white edge reveals a hidden glitch You can group digital waveforms and enter waveform labels by using a USB keyboard By simply placing digital waveforms next to each other
28. nd accurate analysis of common power parameters www tektronix com 7 Datasheet Video design and development Many video engineers have remained loyal to analog oscilloscopes believing the intensity gradations on an analog display are the only way to see certain video waveform details The fast waveform capture rate coupled with its intensity graded view of the signal provides the same information rich display as an analog oscilloscope but with much more detail and all the benefits of digital scopes Standard features such as IRE and mV graticules holdoff by fields video polarity and an Autoset smart enough to detect video signals make these the easiest to use oscilloscopes on the market for video applications And with high bandwidth four analog inputs and a built in 75 Q input termination the oscilloscope provides ample performance for analog and digital video use The video functionality is further extended with the optional video application module which provides the industry s most complete suite of HDTV and custom nonstandard video triggers 10 0MS s 5251 7 Ji 0 0 s l 1000 points NTSC Viewing an NTSC video signal Notice the intensity graded view provided by the DPO s ability to represent time amplitude and distribution over time Designed to make your work easier The MSO DPO3000 is designed to make your work easier The large high resolution display shows intricate signal details Dedicated fr
29. nprecedented efficiency in viewing navigating and analyzing waveform data Zip through your long record by turning the outer pan control 1 Get details from the beginning to end in seconds See something of interest and want to see more details Just turn the inner zoom control 2 Zoom and pan A dedicated two tier front panel control provides intuitive control of both zooming and panning The inner control adjusts the zoom factor or zoom scale turning it clockwise activates zoom and goes to progressively higher zoom factors while turning it counterclockwise results in lower zoom factors and eventually turning zoom off No longer do you need to navigate through multiple menus to adjust your zoom view The outer control pans the zoom box across the waveform to quickly get to the portion of waveform you are interested in The outer control also utilizes force feedback to determine how fast to pan on the waveform The farther you turn the outer control the faster the zoom box moves Pan direction is changed by simply turning the control the other way www tektronix com 3 Datasheet Play Pause A dedicated Play Pause front panel button scrolls the waveform across the display automatically while you look for anomalies or an event of interest Playback speed and direction are controlled using the intuitive pan control Once again turning the control further makes the waveform scroll faster and changing direction is as simple as turning t
30. ont panel controls simplify operation A USB host port on the front panel allows you to easily transfer screen shots instrument settings and waveform data to a USB mass storage device 8 www tektronix com Large high resolution display The MSO DPO3000 Series features a 9 inch 229 mm wide screen high resolution 800 x 480 WVGA display for seeing intricate signal details Dedicated front panel controls Per channel vertical controls provide simple and intuitive operation No longer do you need to share one set of vertical controls across all four channels Connectivity A USB host port on the front panel enables easy transfer of screen shots instrument settings and waveform data to a USB mass storage device The rear panel contains a second USB host port and a USB device port for controlling the oscilloscope remotely from a PC or for connecting a USB keyboard The USB device port can also be used to print directly to a PictBridge compatible printer An integrated 10 100 Ethernet port enables easy connection to networks and a Video Out port allows the oscilloscope display to be exported to an external monitor or projector Compact form factor With the compact portable form factor you can easily move the oscilloscope between labs And with a depth of just 5 8 inches 147 mm it saves you valuable space on your test bench The MSO DPO3000 Series compact form factor frees up valuable space on your bench or desktop MS
31. orm record for the event and analyzing its characteristics and your device s behavior Discover To debug a design problem first you must know it exists Every design engineer spends time looking for problems in their design a time consuming and frustrating task without the right debug tools The industry s most complete visualization of signals provides fast insight into the real operation of your device A fast waveform capture rate greater than 50 000 waveforms per second enables you to see glitches and other infrequent transients within seconds revealing the true nature of device faults A digital phosphor display with intensity grading shows the history of a signal s activity by intensifying areas of the signal that occur more frequently providing a visual display of just how often anomalies occur PITT a l 1000 points 1 30 V Discover Fast waveform capture rate over 50 000 wfm s maximizes the probability of capturing elusive glitches and other infrequent events 2 www tektronix com Capture Discovering a device fault is only the first step Next you must capture the event of interest to identify root cause The MSO DP03000 Series provides a complete set of triggers including runt logic pulse width glitch setup hold violation serial packet and parallel data to help quickly find your event With up to a 5 Mpoint record length you can capture many events of interest even thousands of
32. packet content ensures you quickly capture your event of interest Search Finding your event of interest in a long waveform record can be time consuming without the right search tools With today s record lengths pushing beyond a million data points locating your event can mean scrolling through thousands of screens of signal activity MS03000 Series and DPO3000 Series Mixed Signal Oscilloscopes The innovative Wave Inspector controls give you the industry s most comprehensive search and waveform navigation capability These controls Speed panning and zooming through your record With a unique force feedback system you can move from one end of your record to the other in just seconds User marks allow you to mark any location that you may want to reference later for further investigation Or automatically search your record for criteria you define Wave Inspector will instantly search your entire record including analog digital and serial bus data Along the way it will automatically mark every occurrence of your defined event so you can quickly move between events Prevu M 10 0ms WAR URRY GR OR OR CLOCK DATA i UN Zoom Factor 250 X CLOCK R 50 PE 2 40 0ps 10 0MS s Bus Search events found 116 gt Search IC decode showing results from a Wave Inspector search for Address value 50 Wave Inspector controls provide unprecedented efficiency in viewing and navigating waveform data Analyz
33. pecific data packet going across an 12C bus The yellow waveform is clock and the blue waveform is the data A bus waveform provides decoded packet content including Start Address Read Write Data and Stop Serial triggering Trigger on packet content such as start of packet specific addresses specific data content unique identifiers etc on popular serial interfaces such as IC SPI MIL STD 1553 CAN LIN FlexRay RS 232 422 485 UART and I S LJ RJ TDM Bus display Provides a higher level combined view of the individual signals clock data chip enable etc that make up your bus making it easy to identify where packets begin and end and identifying sub packet components such as address data identifier CRC etc Bus decoding Tired of having to visually inspect the waveform to count clocks determine if each bit is a 1 or a 0 combine bits into bytes and determine the hex value Let the oscilloscope do it for you Once you ve set up a bus the MSO DPO3000 Series will decode each packet on the bus and display the value in hex binary decimal LIN FlexRay and MIL STD 1553 only signed decimal I2S LJ RJ TDM only or ASCII MIL STD 1553 and RS 232 422 485 UART only in the bus waveform MSO3000 Series and DPO3000 Series Mixed Signal Oscilloscopes Capabilities of the serial triggering application modules Technology Trigger Bus
34. s that provide additional signal processing advanced analysis sweeping limit testing and user defined step capabilities For simple tasks the included OpenChoice Desktop enables fast and easy communication between the oscilloscope and your PC through USB or LAN for transferring settings waveforms and screen images titi t LW Signall apres Fie Eat Wee Toss AdsStes Dee Wen Window Heb Qin Bmw eano Geert Atte P Bey AM Dopisy Boos Y rdehee w Movie eae Gea oO R How do I get help cont si U WI te RP Pal i y hy ni i l ij ati ii i j Hi il 1 Hii Wi NI LabVIEW SignalExpress Tektronix Edition is a fully interactive measurement and analysis software package developed jointly with National Instruments and optimized for the MSO DPO Series Tek MS03054 OpenChoice Desktop TX S am m 555 3414 Waveform Get amp Send KA Preferences Data Capture Settings Select Instrument _ MS03054 Get Screen On _ 10 0ms 100KS s Save As 7 j 10k points 3 37 V A S ral D15 D0 gt Timing Resolution 10 0us Copy to Clipboard MS03054 DAC Capture pr Modify Note Tektronix OpenChoice Desktop software enables seamless connection between the oscilloscope and your PC www tektronix com 9 Datasheet Specifications All specifications apply to all models unless noted otherwise Model overview
35. serial packets in a single acquisition for further analysis while maintaining high resolution to zoom in on fine signal details From triggering on specific packet content to automatic decode in multiple data formats the MSO DPO3000 Series provides integrated support for the industry s broadest range of serial buses I2C SPI MIL STD 1553 CAN LIN FlexRay RS 232 422 485 UART and I S LJ RJ TDM The ability to decode up to two serial and or parallel buses simultaneously means you gain insight into system level problems quickly To further help troubleshoot system level interactions in complex embedded systems the oscilloscope offers 16 digital channels in addition to its analog channels Since the digital channels are fully integrated into the oscilloscope you can trigger across all input channels automatically time correlating all analog digital and serial signals The MagniVu high speed acquisition enables you to acquire fine signal detail around the trigger point for precision measurements MagniVu is essential for making accurate timing measurements for setup and hold measurements clock delay signal skew and glitch characterization PreVu Trigger On acorns 25 0MS s Tx Data 1M points j D15 D0 i Timing Resolution 40 0ns gus e 232 Tepara Sn Capture Triggering on a specific transmit data packet going across an RS 232 bus A complete set of triggers including triggers for specific serial
36. tion than comparable MSOs on the market instilling confidence when making critical timing measurements on digital waveforms PET gt Timing Resolution 121ps J The MagniVu high resolution record provides 121 2 ps timing resolution enabling you to take critical timing measurements on your digital waveforms P6316 MSO probe This unique probe design offers two eight channel pods simplifying the process of connecting to the device under test When connecting to square pins the P6316 can connect directly to 8x2 square pin headers spaced on tenth inch centers When more attachment flexibility is required you can use the included flying lead sets and grabbers to clip onto surface mount devices or test points The P6316 offers outstanding electrical characteristics applying only 8 pF of capacitive loading with 101 KQ input impedance The P6316 MSO probe offers two eight channel pods to simplify connecting to your device 6 www tektronix com Serial triggering and analysis optional On a serial bus a single signal often includes address control data and clock information This can make isolating events of interest difficult Automatic trigger decode and search on bus events and conditions gives you a robust set of tools for debugging serial buses Addr R 50 DELE HE E S Data 1A Data 1C DATA 2 50GS S Addr 1M points Data PORTIE I D15 D0 gt Timing Resolution 2 00ns Triggering on a s
37. user interface that does not require any programming Standard support for acquiring controlling viewing and exporting your live analog channel signal data is permanently available through the software The full version SIGEXPTE adds additional signal processing advanced analysis mixed signal sweeping limit testing and user defined step capabilities and is available for a 30 day trial period standard with each instrument Enables fast and easy communication between a Windows PC and your oscilloscope using USB or LAN Transfer and save settings waveforms measurements and screen images Included Word and Excel toolbars automate the transfer of acquisition data and screen images from the oscilloscope into Word and Excel for quick reporting or further analysis Provides a standard instrument programming interface for common applications such as LabVIEW LabWindows CVI Microsoft INET and MATLAB Enables control of the oscilloscope over a network connection through a standard web browser Simply enter the IP address or network name of the oscilloscope and a web page will be served to the browser 9 inch 228 6 mm wide format liquid crystal TFT color display 800 horizontal x 480 vertical pixels WVGA Vectors Dots Variable Persistence Infinite Persistence Full Grid Cross Hair Frame IRE and mV YT and XY gt 50 000 wfm s Input output ports USB 2 0 high speed host port LAN port Ethernet GPIB interface Video out
38. witching loss harmonics safe operating area SOA modulation ripple 5 OO 0000 WOO 0000 and slew rate di dt dv dt Completely integrated into the oscilloscope the i ERA power analysis tools provide automated repeatable power measurements 1597EEA3 DES COFA SDE IC IDAT with a touch of a button no external PC or complex software setup is 1122 3344 required 1122 3344 5566 C1C2 C3C4 B7B6 B4B4 FFFF FFFF FFFF FFFF A 12 0ms 12 0ms 24 0ms X 32 3 V 700mv G V y 24 0mA 128mA 104mA Event table showing decoded identifier DLC DATA and CRC for every CAN packet in a xxy 775mW 89 6mW 3 29W long acquisition SOA Mask Test Passed Waveforms Acquired 382 Failing Samples 0 Search serial triggering Serial triggering is very useful for isolating the event of interest but once you ve captured it and need to analyze the surrounding data what do you do In the past users had to manually scroll through the waveform counting and converting bits and looking for what caused the event You L can have the oscilloscope automatically search through the acquired data for user defined criteria including serial packet content Each occurrence is highlighted by a search mark Rapid navigation between marks is as simple as pressing the Previous lt and Next buttons on the front panel ERN 2 50MS s F 100k points 4 60 V Safe operating area measurement Automated power measurements enable quick a