Home

User Manual - HDL Automation

image

Contents

1. IH 216mm 66mm e Standard 35mm Din Rail Installation Inside Distribution Box DB 1 2 Functions of the HDL MHRCU 433 Functions of the host control module 48 channels Each channel has a lower limit higher limit and maximum limit 99 scenes Each scene has a running time of 0 250 seconds Protection delay Each channel has protection delay time of 0 60 minutes Delay activation Each channel has a delay activation time of 0 250 seconds Card master activation Scenes can be activated according to the status of the card New host module and IHMS User Manual 1 User Manual amp D L HDL MHRCU 433 and IHMS master e RJ45 port The hotel host uses a RJ45 port to connect a room to the reception or management center Using the existing hotel management software the module can be integrated with third party management software Mix control functions Channel 1 to 13 is a relay output the output from each channel is 5A Channel 22 is for doorbell control Dry contract Channel 14 to 17 is a relay output the output from each channel is 10A Channel 18 to 21 is a dimming output the output from each channel is 1A There are 24 channel dry contract inputs The control target must be set via the hotel management software Door bell function e 5 channel LED outputs for stand
2. Device ID 107 1 254 Switch ID 1 255 255 All Switch Switch ID 255 254 LCD Panel take DLP for example 1 4 are buttons of page 1 5 8 are buttons of page 2 255 all keys will be shielded 254 Lock DLP panel Explanation This page is to add panels button list which requires shielding A number of buttons on the panel to add the appropriate number In the scene control page you can setthese scenes are shielded the panels button control Save to module succeed F5 Refresh Current Page Shift F5 Refresh All Pages To shield disable a panel button when a scene is in use the buttons information must be entered into the panel setup window New host module and IHMS User Manual 38 User Manual D L HDL MHRCU 433 and IHMS 7 7 10 Scene tab Room System Data building 1 floor1 1133 Module Edition Ocene SGEE tt a ER EE EE MP M Scene Setup Display scene number 0 99 10 slid Sion Remari amo Ai nditione Notrent unocuppied Managed 8 Managed 1 Ignore Ignore Ignore Ignore Ignore Not rent occupied Ignore Managed 1 Ignore Ignore Ignore Ignore Ignore Rented unoccupied Managed 8 Managed 1 Ignore Ignore Ignore Ignore Ignore Check in Managed 8 Managed 1 Ignore Ignore Ignore Ignore X Ignore Checkin Occupied Managed 8 Managed 1 Ignore Ignore Ignore Ignore Ignore E Scene Valid C Scene Output Sce
3. HDL MHRCU 433 IHMS secet 20n amp 5sotcosz6 NOU NAMEN ENN NE 1 1897 CH 18 21 oY PF ee HPSSeueEeo MHRCU 433 CE RoHS LULA DUSDpro www hdlautomation com User Manual n D L HDL MHRCU 433 and IHMS Document updates V1 0 2015 07 14 Finish new document New host module and IHMS User Manual i User Manual El D L HDL MHRCU 433 and IHMS INDEX UIS UU 1 ROT ONA 1 1 1 1 Description of the IHMS rrrnnnrnnannnvrnannvrnannvnnannvnnanennannrnnannrnnnnnrnnnnnennnnnnen 1 1 1 2 Description of the HDL MHRCU 433 erenrnnrrrnnnrrrnnarrennarsrnrarsennansennannennnnnen 1 1 1 3 Mounting the HDL MHRCU 433 rornennnnnronnnnrvnnnnnnnnnnnnnnnnsrnnannrnnannennannnnnnnnen 1 1 2 Functions of the HDL MHRCU 433 rrerenronnernnnrernnnrrrnnnrrnnnnnnennansennnnnennnnnennnnsennrnnne 1 1 3 Description and Wiring of the HDL MHRCU 433 rrrrnronnrevnrnnrrenvnnnrsnnrnnerennrnsrrennnnn 2 1 4 HDL Buspro Description rarrrnnnrrvnnrrrranrrranrvnnnnnnnnnnnnnrnnnnnnnnnnnnnnnnasnnnnnennnnsennnsennnee 3 2 Safety precautions rrrrnnnnnnrrnnnnnrvrrvnnnnrvnnnnnrnnnnnnsnnnnnnnrnnnnnnnsnnnnnnssnnnnnnnsnnnnnnnrennnnnrennnnnee 3 3 Technical Data for the HDL MHRCU 433 rrarnerranoonrannenrannenrnnrenrnnsrnrnnnenrnnnennnnnennnnsnennnner 4 JO E D 5 Features and introduction to the IHMS r
4. New host module and IHMS User Manual 26 User Manual D L HDL MHRCU 433 and IHMS 7 7 1 Lamp tab Room System Data building 1 floor 1 1133 Module Edition arr zi 1 Y i 1 P 3 1 3 al amp AinGonditonern Curtain enulation fan Notice Rane Othe ouest Stratus scene scene Panel Control Doorbell Dry Contact Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined lamp 18 Undefined 0 lamp 19 Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Undefined Channel ID 4g Channel Remark lamp 18 oooococooocoocococo seg Load Type Undefined Lower limit 9 0 100 Higher limit 499 0 100 Max Level 499 0 100 Switching on 0 0 250 delay 0 189 Protection 0 0 60 delay Min ooooocoocoocooccecca ooooocoocc ccc cc oO Oo nini Read Load from setup succeed F5 Refresh Current Page Shift F5 Refresh All Pages l mame The HDL MHRCU 433 has 48 control channels and 21 Mix control channels the first mix control channel is channel 1 For further information please refer to section 7 5 Set Start Channel of Affiliated Module If there are no other affiliated modules connected to the HDL MHRCU 433 only channels 1 21 can be used in the Lamp tab T
5. New host module and IHMS User Manual 3 amp User Manual isl D L HDL MHRCU 433 and IHMS 3 Technical Data for the HDL MHRCU 433 Electrical Parameters Working voltage DC20 30V Static power consumption 60mA DC24V Dynamic power consumption 300mA DC24V oignal interface HDL Buspro RJ45 INNER Buspro RJ45 interface UDP IP network Interface 16A TRIAC minimum load is 30w Buspro terminal Zz Mill O 0 75 0 85mm single core cable Environmental Conditions Working temperature 0C 45 C Working relative humidity Up to 90 otorage temperature 20 C 60 C Storage relative humidity Up to 93 RoHS 2 2 OD om O lt D Q Product information Dimensions 216x90x56 mm 725 g Housing material Nylon Installation 35mm DIN rail installation Protection degree IP20 D G New host module and IHMS User Manual 4 User Manual amp D L HDL MHRCU 433 and IHMS 4 Topology m ii amp ExFaust Fan Curtain 2immcble Lamps Lights AC220V MHECIU 433 m m Rocml BUS Fower Supply HVAC FCU E d mm uH MormalPanc Door Bel AC Sentel Core Holder Bed Switch 2anel Na creen Etherr et Hub FInaor S dl i Reception PC Hotel PMS ExFaust Fan Curtain 2immcble Lamps Lights AC220V r3 1 2 ud L MHRCW 433 BUS Fewer Supply Room PRE Normal Panel Doo Bel AC Centre Corc Holder Bed Switch Panel HVAC FCU Main Ether
6. safety precaution to prevent commands being issued from other rooms 7 5 Set a Start Channel for an Affiliated Module Section 1 1 2 Description of HDL MHRCU 433 details that the HDL MHRCU 433 has 48 output channels and 21 Mix Control channels In the host module the default start channel for the Mix Control is 1 and the following 20 mix control channels occupy channels 2 21 of the host module The start channel of an affiliated module Mix control can be changed To add another affiliated module it must be connected to the INNER BUS port of the HDL MHRCU 433 If a room is clicked the below interface will be displayed New host module and IHMS User Manual 23 User Manual D L HDL MHRCU 433 and IHMS Fay Hotel Multi Lingual Room Management Software VIDETI Adminis CUratin Ec A LACE ux HL Hotel Manage Reserved Checkin e es A uP Refresh Show Mode Control Mode Setup Mode Add Lamp Select background pecture 1178 S02 Clear background picture Room Element Dicplay Set Start channel of aff ated module Enable Switch Function Room System Data Room Property Current Time 2015 02 09 Monday 20 13 42 E kA M rar amp ACABE mM 2015 7 9 A To enter the setup mode right click on a blank area of screen and select set start channel of affiliated module the below window will then appear Set start channel of affiltated module Set start channel of affiliated module
7. A 5 occupied guest cmd Scene Remark occupied quest car Doorbell Setup universal switch 13 18 EJ Managed Doorbell Status EJ Room Name Lamp Bl Please Laundry fj Please Sweep ll Please do not disturb EJ Doorbell Lamp EJ Card Lamp The status of the HDL doorbell can be managed in each scene in scene 5 occupied guest card the room name lamp doorbell lamp and the card lamp have been set as on 7 7 10 7 Scene Panel Shield Setup Scene Setup Scene ID 5 Scene Remark occupied guest ca Scene Order 5 occupied guest cag Scene Remark occupied guest car Scene Panel Shield Setup EJ Managed B Shield In Scene 5 occupied guest card a button or panel can be disabled via the shield function To enable the shield function the ID of the button or panel must be entered into the Panel Control For further information please refer to section 7 7 9 Panel Control tab New host module and IHMS User Manual 43 User Manual D L HDL MHRCU 433 and IHMS 7 7 11 Doorbell tab Doorbell Function Setup Mode Single on off u NH Input function No from 1 255 Invalid Setthe relationship between LED light EJ wait i E Recovery E Not Control Bl oND E Clean lll Room No Clean E Recovery EJ Not Control Bl Doorbell DND Bl Recovery EJ Not Control Room No E Recovery EJ Not Control Doorbell Bl Recovery EJ Not
8. Kone Ares Deens prupied null card Scene 5 occupied quest car 5cene 6 our of service Current Time 2015 03 17 Thursday 11 46 02 SPs a re Using control mode all the configured devices and appliances in a room can be managed The Scene Panel Shield Urgent Card Status can also be simulated New host module and IHMS User Manual 50 amp User Manual i D L HDL MHRCU 433 and IHMS 9 Application A hypothetical guest room must be set up below are the elements that must be controlled or managed Loads Room targets that will be controlled 3 on off lights wall light down light bathroom light 2 leading edge dimmable lights bedside light reading light 1 curtain 1 FCU 1 ventilation fan Equipment Necessary equipment from HDL to complete the installation 1 2 5 HDL MHRCU 433 1 33 Dry contacts are used to control all lights curtains ventilation fans and the check out functionality HDL MPL8 48 1 107 The AC page is used to control the FCU air conditioning other buttons are used for services such as laundry cleaning etc SB 3S Bell XS 1 5 Enables the room status information to be displayed e g Room number laundry DND clean doorbell lamp and card lamp the door lock relay SB RF MSTR 1 103 The card reader module SB RF Writer The card writer module Requirements How the room should perform 1 When the room is Vacant empty Lights Wall light down light
9. New host module and IHMS User Manual 32 User Manual D L HDL MHRCU 433 and IHMS Tool select panel Device 1 107 HDL MPL8 48 FH YY 107 Curent key 1 Mode Singeon T f Universal switch 2 Switch no On Switch Status N A B When a customer makes a request via the DLP a new window will display their request in the bottom right corner of the IHMS software Current room alarm status Check Qut Hina Se ae oN nicae hh inn onda ee er cima Doorbell Setup universal switch 13 18 Subnet ID 4 Device ID 5 Channel ID of SB DN 48HNET for bell modiy indirect control means when SB DN 48HNET receives universal switch13 18 Indirect Control it will send out universal switch 1 6 to door bell panel Card Reader Setup Universal switch 1 ON Card Reader s Card Reader Type card Reader r1 Subnet ID 4 Device ID 403 Cody Custom Trigger Scene universal switch 10 12 Scene One universal switch 10 Scene ID 1 Delay time before open scene Scene Two universal switch 11 Scene ID 1 Delay time before open scene Scene Three universal switch 12 Scene ID 1 Delay time before open scene save Load from device succeed F5 Refresh Current Page Shift F5 Refresh All Pages Doorbell Setup Input the doorbell panel subnet ID device ID and channel ID Then assign a c
10. 1 AirConditioner Remark center AC E Bist Mmodiy 5 le SL m k Ai Co d li ie i VL a Hoafin 3 Ch nn p Tr 5C ir 3 Chann Exist centerAC Central Air Conditioner 5 3 2 1 1 2 Non existent 3 Non existent 4 Non existent Channel Setup E Central Air Conditioner Fan channel Low 1 Fan channel Medium 2 Eu m Device ID i 107 Fan channel Hiah 3 Heating Channel 4 Cooling Channel 5 Delay Setup 1a7secona ig Mode Close Delay 1 10 Second fan Open Delay 1 10 Second fan Close Delay 4 1 10 Second The HDL MHRCU 433 supports up to 4 air conditioners each AC can be controlled by up to 3 AC Panels thermostats If the AC is centralized you can assign a channel from the HDL MHRCU 433 or affiliated module to the FCU fan coil unit If the AC is centralized but you do not wish to assign channels to an affiliated module or you wish to use IR control channels do not need to be assigned Only input the ID of the AC panel thermostat oeason Setup The air conditioner can be configured so that during different seasons it outputs the most suitable temperature In the below screen shot the air conditioner has been set so that when a room is occupied the AC outputs a temperature of 27 C The season settings take priority over the scene controls New host module and IHMS User Manual 29 Mende Cooling Cong B Ke ni Tarm
11. Control c M I Load from device succeed F5 Refresh Current Page Shift F5 Refresh All Pages Cm When a 3 party standard doorbell panel is used its information can be entered into the doorbell tab and enabling its status to be shown For information concerning wiring and connections please refer to section 1 3 Device Description and Wiring of HDL MHRCU 433 Doorbell Function Setup When the doorbell is triggered the resulting action can be set in the doorbell function setup window Doorbell Function Setup Mode Single on off 7 Input function No from 1 m 1 Single on off Doorbell Information Settings 1 Special setup The wait mode delay time can be configured from 0 3600 seconds New host module and IHMS User Manual 44 User Manual D L HDL MHRCU 433 and IHMS Set the relationship between LED lights The relationship between a 3 party doorbell and its LED indicator lights can be configured here For example when the guest triggers the Wait led status to turn ON the DND led status must be OFF Special Setup Delay Time when in wait mode 0 0 36005 0 Display backlight all the time Set the relationship between LED lights LED light EJ wait Wait E Not Control E DND fl Clean Room No Clean EJ Not Control Bl Doorbell Status El on Doorbell EJ Not Control DND B Not Control Room No EJ Not Control I OFF Doorbell Status t
12. Left 30 Text Top 30 DE Gjem 1 Batch Add This enables you to add multiple lamps at once 2 Information Channel ID This shows which channel the lamp currently occupies in the host module To set the start channel of an affiliated module please refer to section 7 5 Set start channel of affiliated module Brightness This shows the intensity of the lamp with the HDL MHRCU 433 module only channels 18 to 21 are dimmable If other channels are used the brightness must be set 0 or 100 3 Icon Information This section allows the icon information to be edited 4 Remark This section allows a comment or remark to be input New host module and IHMS User Manual 25 User Manual D L HDL MHRCU 433 and IHMS Hide All Rooms building 1 Bm Rooms fey floor 1 Vacancy Reserved fa Checkin B Out Of Service 7 7 Setting room system data fa Hotel Multi Lingual Room Management Software VL08 112 Adm Room System Data building 1 Roar 1 1133 Module Editio VAN v mei TP tCendtone Curtain Ventilation fen Notice Panel Of WED Status Scen Scen vel Control Doorbell Dry Contec EJ s e Add Roon nd Room ar wnter vs Setup Serve St P Channel parameters Setup Lamp Orgar Lamp Channel LampRema 096 Type Lower Amat Higner Wt MaxLevel Seutcning fassione Channel 1 1 Vndetined 9 100 100 g 2 2 Undet hed 0 100 100 g 3 3 Undefined 0 100 100 0 4 4 Uncetned 0 100 100 0 5 Ungef
13. Lingual Room Management Software VILOBIIS Admin Curatin Edition Rc E 7 d Add Room Find Room Candie Sys Setup Senet Statu Ali Rooms lr ar too I Page 1 buiding 1 Bn Ronen M on Hl EU Wi Room name remark Rent status Room no Offline indication Key card type Customer requests Cuncnt lime 2015 02 09 Monday 20 03 40 Click the Alarm area you can check the alarm type of this room New host module and IHMS User Manual 18 User Manual D L HDL MHRCU 433 and IHMS 7 Room Management After a room HDL MHRCU 433 has been added on the IHMS an icon similar to the one shown here will appear on the IHMS Clicking on this icon will enable you to view the room information All Rison bushing 1 Larir I Mesi 113 13 B Rooms building tioo 1113 B e 113 j Shows the default B Checkin qe EN doorbell Pal PST Truc B irent Time 2015 0304 Wednesday 20 26 41 7 1 Current room status ee ee Out Of Service The current room status is Reserved Unsubscribe Check Out Vacancy shown here Checkin Checkin Out OT Service Here we can see the current status of the rooms Using the Control Mode the lease state can be changed which in turn activates a corresponding scene As an example if the room status is changed to vacant the vacant scene will activate which deactivates the lighting and HVAC For further information concerning scene settings
14. Single on Switch Mode Single on Switch Mode Single on Switch Mode Single off Switch Mode Single off Switch Mode Single off Switch Mode Single off Switch Mode Single off Switch Mode Single off Switch Mode Setting for Key Key Enable Panel Lock Key Enable Load from device succeed F5 Refresh Current Page Shift F5 Refresh All Pages The HDL MHRCU 433 has 24 dry contacts which can be connected to ordinary switches This enables the HDL host module to be used in conjunction with ordinary switches Switch Information Enables a user to set the dry contact information Switch Information New host module and IHMS User Manual 1 Single on off Dimmable two way Dimming Low Limit 96 0 100 2 Single on off Dimmable two way N A N A 3 Single on off Switch Mode N A N A 4 Single on off Switch Mode N A N A z 5 Single on off Dimmable increase N A N A 6 Single on off Dimmable reduced N A N A Switch Type Single on off uu f Single on off Switch Mode N A N A 8 Single on off Switch Mode N A N A Remark 9 Single on off Switch Mode N A N A 10 Single on off Switch Mode N A N A 11 Single on off Switch Mode N A N A Mode Dimmable two way i 12 Single on off Switch Mode N A N A 13 Single on off Switch Mode N A N A 14 Single on off Switch Mode N A N A 15 Single on off Switch Mode N A N A 16 Single on Switch Mode N A N A 17 Single on
15. Switch Mode N A N A 18 Single on Switch Mode N A N A Key Enable EJ Enable 19 Single off Switch Mode N A N A 20 Single off Switch Mode N A N A Panel Lock Key Enable z Enable 21 Single off Switch Mode N A N A 22 Single off Switch Mode N A N A 23 Single off Switch Mode N A N A 24 Single off Switch Mode N A N A 46 User Manual D L HDL MHRCU 433 and IHMS Target Information Enables a user to set the dry contact targets Choose Switch nction no Subnet ID Device ID Parameter 1 Parameter 2 Par Target information Function no 4 2 Single on off 3 Single on off Subnet ID 0 255 4 4 Single on off 5 Single on off Device ID 0 255 14 6 Single on off EIN EM 7 Single on off Type Single channel cux 8 Single on off Channel 4 9 Single on off no 1 240 10 Single on off Intensity 0 100 100 11 Single on off 12 Single on off Running 0 13 Single on off time 0 3600s 14 Single on off 15 Single on off 16 Single on 17 Single on 18 Single on 19 Single off 20 Single off 21 Single off 22 Single off 23 Single off 24 Single off 7 8 Set the Room Elements Position Hotel Multi Lingual Room Management Software V1 08 112 Admin Six Curatin Edition Teer Faw s HOL Add Room Find Room Card Sys Setup Serve lt ardWrite e Status History UserManag 4 building 1 s Hide Hotel Manage Software n Rooms building 1Mloor 111133 Vacancy Bn Checkin ES Q 3 Bn 3 Out Of Servic
16. and bathroom lights are turned off Leading edge dimmable lights Bedside light and reading light are both turned off Curtain Closed FCU Off Ventilation fan Closed Doorbell The card icon on the doorbell panel is illuminated approved staff can still open the room door When the room is Reserved null card booked Lights Wall light down light and bathroom lights are turned off Leading edge dimmable lights Bedside light and reading lights are both turned off New host module and IHMS User Manual 51 amp User Manual D L HDL MHRCU 433 and IHMS Curtain Closed FCU Off Ventilation fan Closed Doorbell The Room name number icon and card icon should be illuminated 3 When the room is Check in null card The customer has just been issued with the room card at reception Lights Wall light and down light are at 100 brightness the bathroom light is off Leading edge dimmable lights Bedside light and reading lights are both turned off Curtain Open FCU Cooling amp high wind amp 20 Wait for 3 minutes if the customer does not open the room and insert the card to card reader module the AC will turn off Ventilation fan Open Doorbell The Room name number and card icon should be illuminated 4 When the room is Occupied guest card The guest has checked in entered the room and inserted the card into the card reader module Lights Wall light and down light are at 100 brightness the bath
17. data to others must be enabled To learn more about the AC settings please refer to 7 7 2 Air Conditioner tab 5 SQL Setup WebServer Setup Opera Setup These tabs are used for integration with 3 party products systems Hotel integration introduction HDL s hotel system is a room control system which has been integrated with both the Cenium and Fidelio also called Opera hospitality PMS systems HDL is able to integrate with other PMS systems on an as needed basis Below is a general diagram showing the structure of the HDL hotel system when integrated into a Cenium and Fidelio PMS system The existing integration software modules by HDL 30 March 2015 Cenium integration software module Utilize REST Representative State Transfer technology to integrate with Cenium Features check in checkout DND Maid Request etc 30 March 2015 e Fidelio integration software module The software module is developed based on the Fidelio s sepc FIAS 2 20m Features check in checkout issue key card 30 March 2015 New host module and IHMS User Manual 14 User Manual D L HDL MHRCU 433 and IHMS HDL room control Cenium integration PMS software IHMS software module Individiual room sub system Cenium by HDL Room Host check in check out DND Maid Request tha Individiual room sub system Room Host Router Switch HDL room control Fidelio integration PMS software
18. on the voltag e of the LED light LED indicator shows the switching status of no 1 to no 6 channels Dry Contact 4 5 6DON COM 7 8 9 10 11 12002 IN C iy A gt 24CH Dry Contacts RJ45 Button and Indicator Flickers green when the module is working properly Long press for 2s to set the start channel A long press for 10S will turn the LED red and restore the module to factory settings If the HDL MHRCU 433 is to be used in conjunction with another module connect the additional module to the INNER BUS port of HDL MHRCU 433 New host module and IHMS User Manual amp User Manual D L HDL MHRCU 433 and IHMS Default settings IP 192 168 10 250 Router IP 192 168 10 1 Port 6000 The network segment of the module should be same as the PC Doorbell control Channel 22 of the HDL MHRCU 433 is used to control the doorbell channel Channel 22 is the default doorbell channel 1 4 HDL Buspro Description Connection Information 2 Safety precautions e When installing the module do not exceed a torque strength of 0 4 Nm Power cable for AC should be 2 5mm2 4mm2 load 1 5mm2 2 5mm2 Care must be taken when connecting to the Buspro interface Failure to do so may result in damage to the module irreparable damage may occur to all system devices if the Buspro cable is connected to an AC voltage Ensure good ventilation Avoid contact with the liquids and corrosive gases
19. start channel of affiliated module B Then press the PROG button on the affiliated module until the LED indicator turns red After this then click on Read and the below window will then appear If you wish to change the Mix control s default start channel you must press the PROG button on the HDL MHRCU 433 Get start channel of affiliated module Set start channel of affiliated module start channel of affiliated module Set start channel aoo w C Set the start channel if the channel is to be used in conjunction with the HDL MHRCU 433 module it is recommended that the start channel is set as 1 If an affiliated module like the SB DN RMIX20 is to be used then set the start channel as 23 or gt 23 because the Mix control channels occupied channel 1 to 21 of host module New host module and IHMS User Manual 24 User Manual D L HDL MHRCU 433 and IHMS and doorbell control occupied channel 22 of host module 7 6 Add Lighting In the Setup Mode click this icon EJ or right click the blank area to add lighting lamps When the icon is clicked the lamp will be added to the default site lower left in the window To customize the location of the icon right click on your preferred area in the blank space Batch Add Bl Batch Add Information Channel ID 18 ightness 100 Time 0 Second Remark lamp 18 amp ChannellD Batch ID Font Arial M FontSize 14 un Text
20. x VH as rura aces 26 TE 8 E T He 2f Aaa NO 0 geiles dio ERES 29 TM 30 7 1 4 Ventilation fan tab rarrrrrnrrrrrnnnrorrannrrnnnnnrnnnrrrannennannennannennnnnrnnnnnsennassennnn 31 te 32 New host module and IHMS User Manual B User Manual El D L HDL MHRCU 433 and IHMS T ON A 33 wa OUES EEE EEE 36 FO COINS AUS A a 37 14 9 Panel Conto taD av 38 TWN DCCC VAD REIR 39 7 7 10 1 Scene and Lamp Setup cc ccecccceececeeeeesseeeeseeeeesseeeesseeeeesees 40 7 1 10 2 Air Conditioner Setup iiccsscsccdcccdcccdscedeccdeccdscedenedencdavadanadencdacedenedenccets 40 7 1 10 3 Scene Curtain SeLup idi tone d edet deed ree aee eroe ds 41 7 1 10 4 Scene Ventilation fan Setup eeeeeeeeseeeeeeneeee 42 7 7 10 5 Scene FM Setup rrrrrnnnnnnnnnnnvrnnnnrvnnnnvnnannvnnannennannennannnnnannennnnsennnn 42 7 7 10 6 Scene Doorbell Setup rrrannrnnannrnnnnnrnrnnnnnnannvrnannvnnannnnnannennannennnn 43 7 7 10 7 Scene Panel Shield Setup rarrrrnnnnnnnannvnnannrnnnnnrnnannnnnannennannennnn 43 TPM hr 44 rare NET 46 7 8 Set the Room Elements Position rannrnnnnnrnrnnnnvrnnnnvrnnnnnnnnnvnnannnnnnnnrnnannennnnnsnnnn 47 To DA OPIN CAG EEE 48 EN EEE 48 17 9 2 Read Data EEE 49 8 Monitor and Control rrrrannnnannnnanennannennnnennnrnnanennanennanennanenvunennunennunennunennnnsennnsnennusennesennn 50
21. FM Lamp Non existent Lamp Non existent Non existent Lamp Non existent Lamp Non existent Lamp Non existent Lamp Non existent Lamp Non existent Lamp Non existent ool Cn in a CO BO aoe bd B Cn Cn qe Q3 BM qe C2 qo E 7 7 8 Scene Status tab Room System Dat Reserved Null Card Checkin Null Card Occupied Null Card Vacancy Guest Card Reserved Guest Card Checkin Guest Card Occupied Guest Card Waiter Card Room Status Purifier Card Mender Card Manager Card Scene Order 1 Not rent unocuppie Out Of Service There are 13 fixed scenes for each scene you can select the Scene ID Before this is done the scene must first be setup To do so the Scene tab must be used As an example if the room status is vacancy null scene no 1 Not rent occupied will be activated ST Save to module succeed F5 Refresh Current Page Shift F5 Refresh All Pages New host module and IHMS User Manual 37 User Manual D L HDL MHRCU 433 and IHMS The HDL MHRCU 433 can switch to and run different scenes according to the rent status and the keycard type used Here occupied means the rent status of room from when the customer inserts his her key card first time until he she checks out successfully Occupied does not refer to the guest being in or out of the room 7 7 9 Panel Control tab FOES Oe FE NS estere n ordlista eee is ET SATIS SO 255 All Switch
22. HMS 7 2 Room tool bar Please find below a brief explanation of the toolbar icons 1 Return or go back a step 2 Show mode In this mode you can check requests and the room device status 3 Control mode In this mode room devices can be controlled by clicking on them and Scene Panel Shield Urgent Card Status can be simulated 4 Setup mode In this mode a room can be configured adjusted Under Setup mode we can use the functions found under icons 5 to 10 5 Room element display Displays elements present in the room 6 Room element setting Allows the element settings to be changed 7 Add lamp Allows a lamp light to be added to the system 8 Set background picture Enables an image or picture to be added to the background of the display window 9 Enable switch function Enables switch functions 10 Enable switch function Debug level Enables switch functions Debug level 7 2 Room Element Display If the room element display icon is selected all the elements appliances devices in the room will be displayed New host module and IHMS User Manual 21 User Manual HDL MHRCU 433 and IHMS 1 1 Air Conditioner 2 Air Conditioner 3 Air Conditioner 4 Air Conditioner 1 Curtain 2 Curtain 3 Curtain 4 Curtain 5 Curtain B Curtain 1 Ventilation fan 2 Ventilation fan 3 Ventilation fan 4 Ventilation fan 5 Ventilation fan 1 FM Non existent Non existent Non existent Non existe
23. ICAU PICU Gt est carc ra Scene Order 5 occupied guest car Scene Remark occupied guest card Channel ID 0 Second 19 Lamp Remark lamp 19 E Control tonnes Running Time E l Second In scene 5 occupied guest card lamp 18 and lamp 19 have been turned on 7 7 10 2 Air Conditioner Setup ene I D 5 Scene Remark occupied guest car Scene Order 5 occupied guest car Scene Remark occupied guest card Cooling High Wind Non existent Non existent Non existent Air Conditioner 1 Remark center AC Wind High Wind aid E WindSweep Cooling Temperature cm EB Heating Temperature et e e Auto Temperature EJ managed Dehumidification New host module and IHMS User Manual 40 amp User Manual D L HDL MHRCU 433 and IHMS In Scene 5 occupied guest card the air conditioner has been turned on Panel lock If the panel lock option is selected the IHMS software runs scene 5 occupied guest card locking the DLP AC page To enable the panel lock the ID of the DLP panel must be entered into the air conditioner tab for further information please refer to section 7 7 2 Air conditioner tab 7 7 10 3 Scene Curtain Setup Scene Setup Scene ID 5 Scene Scene Order S occupied guest cdg Scene Remark occupied guest car 1 2 Non existent 3 Non exi
24. IHMS software module Individiual room sub system Fidelio also called Opera i by HDL Room Host Individiual room sub system Room Host check in check out issue key card V 1 Router Switch 5 3 5 Serve Status Add Room Find Room CardWriter Sys Setup Serve Status History UserManage Hide Floor Ro EJ All Room building 1 floor 1 00 00 00 67 00 00 00 05 192 168 10 199 Bl Alarm Room Notice Status E Notice Check out E Notice Thief E Notice Help E Notice Door 8 Serve One 8 Serve Two E Serve Three E Please Laundry E Please Sweep Check the notifications made for all rooms or search via specific notifications New host module and IHMS User Manual 15 User Manual D L HDL MHRCU 433 and IHMS 5 3 6 History l Hotel Multi Lingual Room Management So Add Room Find Room CardWriter Sys Setup Serve Status History UserManage Hide 1 Card Log Shows a record of the cards activity 2 Alarm Log Shows a record of the notifications made from each room 3 DoorLock Log Shows a record of the door lock activity 4 Record card Stores the records from issued cards If a card is lost the cards access privileges can be revoked 5 3 7 User Management a Hotel Multi Lingual Room Management Sc Add Room Find Room CardWriter Sys Setup Serve Status History UserManage Hide New host module and IHMS User Manual 16 User Man
25. L HDL MHRCU 433 and IHMS 7 9 2 Read Data Room System Data building 1 floor 1 1133 Module Edition Scene Setup Display scene number 0 99 10 Reserved null c checkin null c 1 2 3 4 5 6 7 8 9 10 M p Save to module succeed F5 Refresh Current Page Shift F5 Refresh All Pages The current data must be read before it is changed in the Room System Data Window Database Reads the data from IHMS Module Reads the current data from the HDL MHRCU 433 module Other Room Reads the data from another HDL MHRCU 433 module Templet Reads the data from the tpt file New host module and IHMS User Manual 49 User Manual D L HDL MHRCU 433 and IHMS 8 Monitor and Control 8 1 Show Mode Hotel Multi Lingual Room Management Software VLOS 112 Admin Six Curatin Edition GE Be P 1 KOG I All Rooms x building 1 se EE Rooms building foor 111123 acs y Reserved Checkin D es Aug Of f rver rs Current Time 2015 03 12 Thursday 11 43 37 In Show Mode a user can check requests and the status of devices appliances 8 2 Control Mode fii Hotel Multi Lingual Room Management Software VLORII2 AdminibhkCuratin Edition All Rooms Pun 1 Land 1 Bn Hines m rU relies Sar Meher Conil Made teup Mode Toeni Srene 1 Net rent unaccupied Panel Shield Erene 2 Resersed rull card Urgert Card Status Scone X checkin rull card
26. Lamp lamp 19 creme hannel Remark lamp 18 0 C Cn WH Load Type Undefined Lower limit 0 100 Higher limit 0 100 Max Level 0 100 Switching on 0 250 delay 0 18 je Protection o 0 60 delay Min Inde eq Undefined 8 Dimmer Voltage The dimming voltage can be selected toner Curtain Ventilation fan Notice Panel Channel parameters Setup 1 1 Undefined 0 100 100 2 2 Undefined 0 100 100 3 zI Undefined 0 100 100 4 4 Undefined 0 5 5 Und 6 8 Unc 7 9 Und d Channel ID 8 10 Unc Dimmer Voltage select a Bl 110v El 220v Channel Remark Mee 11 13 Und 13 15 Undi 14 16 Und Load Type 15 17 Unc ype Undefined mm 16 18 Under 17 19 Undefined 0 18 20 Undefined 0 100 100 Lower limit g 0 100 19 21 Undefined 0 100 100 20 22 Undefined 0 100 100 Higher limit 0 100 21 23 Undefined 0 100 100 22 24 Undefined 0 100 100 Max Level 0 100 79 DE I Indafinnrt n ann ann New host module and IHMS User Manual 28 User Manual D L HDL MHRCU 433 and IHMS T f 2 Air Conditioner tab E hir Gonditoner d an Notice Panel Other nunc Ctatic Srana Crane Danal C f f Lamp alike BN GIOHES an Notice Pane One GUEST latus Scene scene anel Control Doorbell Dry Contact paiements Bi a m nata datis c aimi s acti clnadlM ADIRE lere EEE Blei Air Conditioner Setup Air Conditioner Order
27. No Edition Status Belo Search Hotel O 1 1133 HDL_V2 1 2U_ 2015 01 12 192 168 010 199 Free IP Select 192 188010161 Subnet Mask 255 255 255 000 E Managed Room EJ Free Room Order E HDL MAC 00 00 00 67 00 00 00 05 IP 192 168 010 199 Subnet Mask 255 255 255 000 Router IP 192 168 010 001 Netmac H D L 5F 42 31 Room No 1133 Only 4 digits Subnet ID 1 Device ID 33 s dk der A Module Edition HDL V2 1 2U 2015 01 12 1 HDLMAC The MAC address gives the unique hardware ID of the HDL MHRCU 433 00 00 00 67 00 00 00 05 The address can be changed with a tool supplied by HDL 2 IP Theunique IP of the HDL MHRCU 433 is 192 168 10 199 3 Router IP The gateway IP is 192 168 10 001 4 NetMAC The unique Ethernet MAC of the HDL MHRCU 433 is H D L 5F 42 31 New host module and IHMS User Manual 8 User Manual i D L HDL MHRCU 433 and IHMS 5 3 2 Find Room To find rooms which are vacant or have pending service requests select the Find Room icon fa Hotel Multi Lingual Room Management Software VLOB 112 AM IQ 2 L E 7 Add Room Find Room CardWriter Sys Setup Serve Status History UserManage Hide Input the room name M Find Content EGEDE EJ Checkin Status EJ Card Status lll Notice Status Checkin Status Card Status Notice Status EJ vacancy EJ huit Notice Check out E ignore EJ Re
28. Scene triggers This page is use to set the scene delay time Scenes can be triggered by universal switch numbers 10 11 and 12 sending an on command For further information concerning scenes please refer to section 7 7 10 Scene tab Custom Trigger Scene universal switch 10 12 Scene One universal switch 10 Scene ID 1 Delay time before open scene 9 Scene Two universal switch 11 Scene ID 4 Delay time before open scene Q Scene Three universal switch 12 Scene ID 4 Delay time before open scene Q New host module and IHMS User Manual 35 User Manual D L HDL MHRCU 433 and IHMS 7 7 7 Guest tab Guest leave delay time delay to run the occupied null card scene Guest leave delay time 0 Minute 10 Second 0 60Minute Modity i Air conditioner control E Turn off air conditioner OverTime 0 Minute 0 Second 0 10Minute Mecane save Turn off air conditioner automatically if customers have checked in but not entered the room after a certain period of time Ej Tum off air conditioner OverTime Q Minute 0 Second 0 10Minute Turn off air conditioner automatically if customers had entered but later left the room over a certain peroid of time Ej Turn off air conditioner Keep air conditioner from turning on in checkin null card scene if the AC was off before customer withdrew the card and left the room Rocovery setup which device should be recovered to former status and which
29. acancy Reserved NullCard 3 reserved null Checkin Null Card 1 check in null Occupied Null Card 5 occupied null Vacancy Guest Card Null Reserved Guest Card Null Checkin Guest Card Null Occupied Guest Card 4 occupied guest Waiter Card 6 waiter Vacancy Null Card Purifier Card Null Mender Card Null Manager Card Null 2 vacancy Out Of Service 2 vacancy Null 1 check in null 3 reserved null 4 occupied guest 5 occupied null 9 Dry contact settings The dry contacts can be used to control the lights curtains fans and one dry contact used for guest checks out Dimming Low Limit 0 96 0 100 1 Single on off Dimmable two way 2 Single on off Dimmable two way reading light 3 Single on off Switch Mode wall light 4 Single on off Switch Mode N A down light NIA F 7 5 Singleonioft Swith Mode N A bathroomlight N A p 6 Single on off Switch Mode N A X curtain open N A Switch Type Single on off im 7 Single on off Switch Mode N A curtain closed NIA 8 Single on off Switch Mode N A fan N A Remark bed light 9 Single on off Switch Mode N A N A 10 Single on off Switch Mode NIA for check out N A 11 Single on off Switch Mode N A N A Mode Dimmable two way i 12 Single on off Switch Mode N A NIA 13 Single on off Switch Mode N A NIA 14 Single on off Switch Mode N A N A 15 Single on off Switch Mode N A N A Dimming Save 16 Single on o
30. arch for rooms that are available or have pending service requests 3 Card Reader Write key card 4 Sys Setup Set system parameters such as customized service names and resolution etc 5 Serve status Show the guest service request history 6 History Show the card log alarm log and the door lock log 7 User Manage View add delete or modify a user account 8 Hide Minimize the program 9 9 Tools 5 3 1 Add Room To search and find online rooms click on the Add Room icon One room refers to one HDL MHRCU 433 host module a Hotel Multi Lingual Room Management Software V1 08 112 Admin Six Curatin Edition mo S Add Room Find Room CardWriter Sys Setup Serve Status History UserManage Hide New host module and IHMS User Manual T User Manual i D L HDL MHRCU 433 and IHMS Search online HDL MHRCU 433 Search Hotel E Search Hotel IP Select 192 168 010 161 Subnet Mask 255 255 255 000 N EJ Managed Room EJ Free Room Online HDL MHRCU 433 ao o M he MAC information refers to the MAC of the DL MHRCU 433 not the thernet MAC Room Data Order 1 HDL MAC 00 00 00 67 00 00 00 05 Managed Room Rooms that have already been added Free Room Rooms that have not yet been added Recv MAC information Information for the host module HDL MHRCU 433 View or modify parameters VT Order Room
31. ard doorbells Third party doorbell status is also supported LED output amp 6 channel common switch indicator outputs for 1 to 6 dry contact channels 1 3 Description and Wiring of the HDL MHRCU 433 ee ela me ERA CERAM I i mL OUT T L N 2T i 38 vn Gr tistriut owe coms OOCOC OC Ot Q OQ0O0O00000 sees COM 1 2 3 4 5 H ADC24 COM 12 3 45 6 XN VL pos IN 277 C NIEDI 9 HDL Jh1 1 y l i 20000000JR000 Oi O gt Indicator of fuse PTS I Git 08 21 i 7 QQOULUCLIOQIODOODEDDO NT 13 14 15 16 17 18DC24V COM 19 20 21 22 23 24 DC2MV Fuse socket ir dit MHRCU 433 TE Prog C RoHS M LU O0O0O0O0000 O00O0O0000 eg fecofffeces Eoed JL 3 H come AH T 57 con ae ee ae ee coma m I HDL BUS i A Doorbell INNER BUS 5CH LED indicators for 3rd party doorbell control The resistor is between 1kQ and 5kQ this depends
32. arget setting Each doorbell status can have a maximum of 10 targets Setting ol Invalid Invalid Invalid Invalid Invalid Invalid Invalid Invalid Invalid Invalid LED light status EJ on i Single channel control zii Curtain switch GPRS control Pannel control m Load from device succeed F5 Refresh Current Page Shift F5 Refresh All Pages Security Module MERE Z audio control Function no 1 fl Clean Subnet 255 Bl Room No Device 255 lll Doorbell Type Invalid Q Co C Qn amp ON Bite cocoococoococoo O oO o o o o o o CFS e New host module and IHMS User Manual 45 HDL 7 1 12 Dry Contact tab uv System Vata buildina 1 floor 1 1133 Module Edition User Manual HDL MHRCU 433 and IHMS Switch Information oN C Cn amp Co ho E Single on off Dimmable two way Single on off Dimmable two way Single on off Single on off Single on off Single on off Single on off Single on off Single on off Single on off Single on off Single on off Single on off Single on off Single on off Switch Mode Switch Mode Switch Mode Switch Mode Switch Mode Switch Mode Switch Mode Switch Mode Switch Mode Switch Mode Switch Mode Dimmable increase Dimmable reduced Dimming Low Limit 0 100 Switch Basic Information Switch Type Single on off 1 Remark Mode Dimmable two way m Dimming EJ Save
33. device needs notto do that after the guests come back and insert their room card Load from device succeed F5 Refresh Current Page Shift F5 Refresh All Pages Guest leave delay time When a guest removes their keycard from the card reader a delay time can be programmed This enables the HDL MHRCU 433 to activate the occupied null card scene after a set time has elapsed Here occupied means the rent status of room from when the customer inserts his her key card first time until he she checks out successfully Occupied does not refer to the guest being in or out of the room Recovery Normally when a guest withdraws their key card and exits the room the occupied null card scene will activate When the guest returns and replaces the keycard into the card reader the scene last used will be activated This function can be deactivated via the shield function New host module and IHMS User Manual 36 User Manual HDL MHRCU 433 and IHMS Air Conditioner Exist center AC T Shield Air Conditioner Non existent Air Conditioner Non existent Air Conditioner Non existent Curtain Exist P Shield Channel 6 7 ai Non existent Non existent Non existent Curtain Non existent Curtain Non existent Doorbell 7 Shield Panel Shield 7 shield Ventilation fan Exist ventilation fan 7 Shield Ventilation fan Non existent Ventilation fan Mon existent Ventilation fan Non existent Ventilation fan Non existent
34. e A B Current Time 2015 03 12 Thursday 11 02 30 SPI 7T The room elements can be seen in the above screen shot After the room elements have been configured clicking and dragging the icon will change its position New host module and IHMS User Manual 47 User Manual D L HDL MHRCU 433 and IHMS 7 9 Save and Read 7 9 1 Save data Room System Data building 1 floor 1 1133 Module Edition Scene Setup Display scene number 0 99 10 Notrent unoccupied Managed 2 Managed 1 Managed 1 Managed 1 Managed Ignore Reserved null card Managed 2 Managed 1 Managed 1 Managed 1 Managed lgnore checkin null card Managed 2 Managed 1 Managed 1 Managed 1 Managed Ignore occupied null card Managed 2 Managed 1 Managed 1 Managed 1 Managed lgnore occupied guest car Managed 2 Managed 1 Managed 1 Managed 1 Managed 11 cni a Ignore Please select room pom Q c CO C WH aT LJ e GEOOCCCOCCE Save To Module Save To Database Save To Templet Save To File After the room data has been changed it must be saved in the Room System Data Window Save To Module Saves the data to the HDL MHRCU 433 module Save To Database Saves the data to the IHMS Save To Templet Saves the data as a tpt file in a default directory Save To File Saves the data as a tpt file with a selectable directory New host module and IHMS User Manual 48 User Manual D
35. e DLP and the TYPE must be set as NEW Air Conditioner Setup Air Conditioner Order 1 Air Conditioner Remark central AC Fi s Exist f Mody C New host module and IHMS User Manual 62 User Manual D L HDL MHRCU 433 and IHMS E DUP Panel with AC buer Clock Foo Hrakrup Bane mioenaton Key aemgnaeen Ar condoning funcion Floor Heat Muse pape base seen fane lamaen avi 4 law normen Synchronous Contr aha knenen Surt ID 1 Mose MOL MPLS AE Je Remates corte Send when power OM iter AG Puma J Subnet ID 1955 Device ID 25 b Button control Buttons 1 4 are used to control laundry DND cleaning and the doorbell For more information concerning universal switch use and notifications please refer to step 11 To enable the help service ensure that the host module subnet ID is set as 1 and the device ID is set at 33 E DLP Panel ERF AC Music Clock foer Heating Sod band Device 1 107 HDL MPL8 48 FH DLP v Current key 1 Mode Single on off feme ya FR Mode 1 Single on off Universal switch 1 Switch no On Switch Status 2 DND Single on off 3 sweep Single on off 4 doorbell Single on off 5 help Single on off Universal switch tend no Key information wm v F je Function configuratio
36. e and IHMS User Manual 30 User Manual D L HDL MHRCU 433 and IHMS 7 7 4 Ventilation fan tab Room System Data bui ding 1 floor 1 1133 Module Edition i mM gt EE am Ventilatinn fan u M gt c 4 Am A anditaner ice anc ha Quest Static Srane 2cona ane snire pf ATI l JAGGE de SNU INDICE T die za SUE SL alus cene LET alit 211 MI Doorbell Dry Contact Ventilation Fan Ventilation Fan Remark ventilation fan ventilation fan 8 Non existent Non existent Non existent Non existent Ventilation Fan channel Ventilation Fan Time Ventilation Fan 8 Fan Runninq Time 0 250 Second Fan Stop Time 0 250 Second Y Load from device succeed F5 Refresh Current Page Shift F5 Refresh All Pages The HDL MHRCU 433 supports up to 5 ventilation fans each fan must be assigned a single channel from the HDL MHRCU 433 The running time of the fan can be customized as shown in the above screen shot If the settings in the screen shot are implemented the fan would be active every other second ON 1s gt OFF 1s gt ON 1s gt New host module and IHMS User Manual 31 User Manual D L HDL MHRCU 433 and IHMS 7 7 5 Notice Panel tab Room System Data building 1 floor 1 1133 Module Edition Sem valid E Over Time 0 250s 5 Door Control Effect Efect Chann i Effect Channel g OpenTime 4 CloseTime 4 Check out Panel universal
37. e openscene g 6 Guest settings Set the guest leave delay time as 1 minute then set a 3 minute delay time to turn off the AC when guest has checked in but not entered into the room Guest leave delay time delay io run the eccupied null card scene Guest leave delay me Minuie fo Second 0 50Mimute ir condilioner cxnirol s Turn aff sir conditioner hir Time Minde 0 Second O TOdMmute Tum off air conditioner automatically if customers have checked in bul not entered ine room after a certain period of tme E Tum aff air conditioner Tum of air conditioner automatically customers had entered but later left the room over a certain perold of time 7 Scene setup As an example the Check in null card scene Lights Wall light and down light are at 10096 brightness the bathroom light is off Leading edge dimmable lights The bedside light and the reading light are both off Scene Order 4 chackin null i i E Seane valid Seane Remarc eheck in null p E Scene Output Second Second 15 baimmreom ligh 18 bed light Que Managed D Second 19 aang light GJ managed Second 20 ignore Lamp Remark 3 ignore wall light 24 ignora st HRS E contrat 3 ignore 27 J Ignore Bikghlness 100 H J ignore zu ag M x2 ignore ii ignore Running Time 0 Second 34 Ignore 35 3 Ignore 3 New host module and IHMS User Ma
38. eives universal switch13 18 Card Type EJ Guest Card Bl waiter Card Bl Purifier Card lll Mender Card Bl manager Card 13 Doorbell setup using the HDL BUS Pro setup tool The switch function can be enabled from the host module this allows a user to search for devices via the HDL BUS Pro setup tool New host module and IHMS User Manual 61 User Manual HDL MHRCU 433 and IHMS The Hotel Name Building ID Storey ID and Room ID must be the same on both the host module and the room card f Hotel Digital doorbell Doorbell Settings Hotel Panel Settings Hotel Panel Settings e HDLHOTEL Building ID 01 Storey ID 01 Room ID 1133 E Refresh 14 Card reader setup using the HDL BUS Pro setup tool The Hotel Name Building ID Storey ID and Room ID must be the same on both the host module and the room card eem c a dues a v 24 ro setup too VIVU 15 50 E Glass RF Card Reader II 44 Basic information Key assignation d Hotel Panel Settings Hotel Panel Settings Hotel Name HDLHOTEL Building ID p Storey ID 01 Room ID 1133 Enable authentication card Refresh 15 DLP setup using the HDL BUS Pro setup tool a AC control The ID of the host module must be input into the AC page In the below example the AC has been added into order 1 so AC No 1 must be entered into th
39. es 7 System protection 2011 Microsoft Corpo h OR Haman Interface Device Hj Advanred sytem erib Gui mon exui witha i ig IDE ATA ATAPI controller OM imaging devices System Z Keyboards Processor gt L Mee and other pointing devices tee nt vet Kf Netwerk adapters Synem typer gt di Pri queues Prn and Tex hi LE Processors How do you want to search for driver software Search automatically for updated driver software i i Windows will search your computer and the Internet for the latest driver software i for your device unless you ve disabled this feature in your device installation i Browse my computer for driver software Locate and install driver software manually New host module and IHMS User Manual 10 User Manual D L HDL MHRCU 433 and IHMS 3 Select the USB Card Writer Driver on the installation path of IHMS Browse for driver software on your computer Search for driver software in this location Include subfolders gt Let me pick from a list of device drivers on my computer This list will show installed driver software compatible with the device and all driver software in the same category as the device 4 Updated successfully The best driver software for your device is already installed Windows has determined the driver software for your device is up to date USBXpress Device Suing No ring s Fer rfoori z Room No 11133 z EB Authorize key card to roo
40. ete All Pages 3 BEEN EEC ae A a E eh Monexistent 3 Non existent 4 Non existent 5 Non existent 9 Non existent Channel Setup Forward channel detay Backward channel delay Forward channel 6 Switching on delay 0 0 3600 Second switching on delar 0 360019econd Backward channel 7 Protecbon delar 0 3600 Second Protecton delay 0 0 3600 Second Running Time 10 0 3600 Second Running Time 10 0 3600 Second 4 Add Ventilation fan Assign channel 8 to the fan Ventilation Fan channel venwabonFan 8 ventilation Fan Time Fan Runaina Time 1 0 25018e00nd Fan Stop Time 1 0 250y8ecand 5 Match the Doorbell panel and Card Reader module Enter the doorbell panel ID and the card reader module ID and assign channel 22 to the bell New host module and IHMS User Manual 55 User Manual D L HDL MHRCU 433 and IHMS TES Ly j ua nl Doorbell Enhupiuriversal switch 13 18 SubetID Device ID 5 mchnect control mins when thes host merests oneal switch 13 18 it wall end out unnersal switch 1 6 to door bell panel Indirect Gortra E ru E Custam Trigger 3cene untvers al sich 10 12 Some One universas seach 10 Somme i 4 Delay iret belote open scone g Scene Two universal switch 11 Seeme ID 4 Delay lire before open scene n Scene Three Universal zwitetr12 Scenic g Delgyfime befor
41. ff Switch Mode N A N A 17 Single on off Switch Mode N A N A Setting for Key 18 Single on off Switch Mode N A NIA Key Enable E Enable 19 Single on off Switch Mode N A N A 20 Single on off Switch Mode N A N A Panel Lock Key Enable Enable 21 Single on off Switch Mode NIA N A 22 Single on off Switch Mode N A NIA Switch 1 Controls the bedside light the host module subnet ID is 1 the device ID is 33 and channel 18 is connected to the bedside light Choose Switch Single channel control 2 Single on off 3 Single on off Subnet ID 0 255 4 Single on off 5 Single on off Device ID 0 255 33 6 Single on off 7 Single on off Type Single channel ccr ae on off esse 9 Single on off no 1 240 10 Single on off Intensity 0 100 0 11 Single on off 12 Single on off Running 0 13 Single on off time 0 3600s 14 Single on off New host module and IHMS User Manual 59 User Manual amp D L HDL MHRCU 433 and IHMS Switch 6 Controls the opening of curtains the host module subnet ID is 1 and the device ID is 33 The curtain is to be controlled in Curtain Order 1 see setup 3 so the target switch number for the curtain is set as switch No 1 1 fori 1133 Module Edition Room System Data buildi meter r Target information Choose Switch 1 Single on off Function no 2 S
42. hannel to the bell If the bell is connected to the doorbell channel see Section 1 3 Description and Wiring of the HDL MHRCU 433 for details channel 22 must be assigned to the bell New host module and IHMS User Manual 33 User Manual i D L HDL MHRCU 433 and IHMS To setup the doorbell please follow the steps shown below 1 Settings Using the IHMS software open the settings tab to adjust the universal switch number gt building 1 floor 111133 Out Of Service Ure Vacancy tas The doorbell position 4 Wn AAS WU e UP Universal Switch ID Please Wait Refresh Please Laundry 3 6 Left m Show Mode Control Mode Please do not disturb Right lg v Setup Mode Select background picture 1178 502 Clear background picture Room Name Lamp Room Element Display Doorbell L 5 Doorbell Pos Setup 00 amp Doorbell Properties Room Property In Setup mode right click the doorbell panel and go to the Door Pos Setup Return to the Control mode to check if the doorbell operates correctly 2 Control Direct Control Direct control is provided by any DLP or button panel that sends a universal switch number to a doorbell panel The doorbell position Universal Switch ID Please Wait Please Laundry 3 Please do not disturb Please Sweep Room Name Lamp Doorbell Lamp EJ Card Lamp Indirect Control Indirect control is provided by any DLP
43. he Lamp tab is able to show the unassigned channels and the lamp channels 1 2 3 Channel ID Channel ID of HDL MHRCU 433 there are 48 channels in total Lower limit If the brightness level is lower than the Lower limit the channel will be shut down By default the limit is set at 0 Higher limit If the brightness level is above the higher limit the channel will reach its max level By default the limit is set at 100 The higher limit should not be set higher than the Max Level Max Level By default the max level is set at 10095 The maximum level must be set above the higher limit owitching on delay This is used to reduce the impact from multiple channels switching on at once Protection delay This is used to make sure that the time between channels last on and next on is longer than the protection delay time As an example if the protection delay time is set at 1 min the channel is switching from on to off If a user then tries New host module and IHMS User Manual 27 User Manual D L HDL MHRCU 433 and IHMS to turn the channel on again after 4 seconds later a further 56 seconds must elapse before the command is completed re 7 Assigned Channel Shows the assigned channels and the lamp channels Channel parameters Setup d Channel LIL AE TESE J SEL Bhannel Status Curtain1 Forward channel Curtain1 Backward channel Lamp lamp 18
44. hile you are in the control or setup mode 2 Basic system settings New host module and IHMS User Manual T2 User Manual HDL MHRCU 433 and IHMS Custom Card Notice Guest Card Waiter Card Mender Card Manager Card Change Language The room key cards can have a customized description 3 Notice Setup Notice Setup Check Out Check Out Thief Thief Help ign iority Exi NoticeHelp wav dnd is se gj es Please Laundry ig Laund Priority NoticeLaundry wav Browse Playa 9 show Please Sweep ign NoticeSweep wav Browse Pla Serve One ign iority Normal NoticeServeOne wav Growse Pay E Show Serve Two ign iority NoticeServeTwo wav Serve Three AN Set text notifications 4 Season Setup New host module and IHMS User Manual 13 User Manual i D L HDL MHRCU 433 and IHMS Season Setup E Broadcast the season data to others Summer Start Time 6 Stop Time 9 Winter Start Time 9 Stop Time Venaas Different seasons can be allocated different dates these dates can then be used to set the AC parameters If the season function is used Broadcast the season
45. ined 0 100 100 n b 6 a bedroom Undefined 0 100 100 7 7 breadright Undefined 0 100 100 meserved i 5 c readiett Undefined 0 100 100 0 T 9 E d entry Undefined 0 100 100 Checkin S e 020 10 10 e bamroom Undetned 0 100 100 11 n I muttor Undefined 100 100 g 12 t2 g night Undefined 0 100 100 13 13 DND Undefined 0 100 100 0 14 14 MUR Ungcetned 0 100 100 0 15 15 hell Undetned 100 100 16 16 h Bafhroom Entry Undefined 0 100 100 0 7 7 Uncetned 0 100 100 0 18 18 lamp 18 Uncetned 0 100 100 19 19 lamp 19 Undetned 100 100 20 20 Undefined 0 100 100 21 21 Undetned 0 100 100 0 22 22 Undefined 0 100 100 23 21 Undetned 100 100 24 24 1 Shower Undetred 0 100 100 g 25 25 Dressing Moons Undefined 0 100 100 0 26 26 kLounge Undefned 0 100 100 27 27 Dest Undefined 0 100 100 0 28 28 m Todtet Undetned 0 100 100 29 29 Undefined 0 100 100 3 30 Uncetined 0 100 100 0 gt re Load trom device succeed S Retresh Current Page SniF5 Retresh All Pages Current Time 2015 03 05 Read z EE The elements that make up a room such as doorbell panel curtains lights fans and A C etc can be set in the room system data window 1 Before modifying the settings read the host module settings first 2 After the modifications have been made they must be saved to the host module 3 For further information concerning Read and Save please refer to section 7 9 Save and Read
46. ingle on off i 3 Single on off Subnet ID 0 255 1 4 Single on off 5 Single on off Device ID 0 255 Type Curtain switch my 7 Single on off 8 Single on off 9 Single on off 10 Single on off 11 Single on off 12 Single on off 13 Single on off 14 Sinnle nninff Switch no 4 Switch status 277 owitch 10 Is used for the guest check out process the host module subnet ID is 1 and the device ID is 33 When the host module receives universal switch no 2 on command it signifies that the guest wants to check out m Room System Data building Choose Switch mete r Target information 1 Single on off 2 Single on off 3 Single on off Subnet ID 0 255 1 4 Single on off i 5 Single on off 6 Single on off 7 Single on off ae on off Switch no 1 48 2 9 Single on off Function no 4 Device ID 0 255 33 Type Universal Switch Switch status ION lid 11 Single on off 12 Single on off 13 Single on off 14 Single on off 10 After the room data has been set it needs to be saved to the module Closing the Room System Data window will display all the devices targets present in the room E MDL Mar AR xxn Find Irc we Slatus Heslon are 3 CardWr er Sys Setup Se y UserManage All Roim ww buskding 1 5 M iios building Toor 11133 Y NL T r Ct Chec
47. kin D x H u H p wall light Gown light bathroom light bed ighi reading tight O Step certain FAM New host module and IHMS User Manual 60 HDL User Manual HDL MHRCU 433 and IHMS 11 Doorbell setup in IHMS Checkin e ev Cortral Sede W Setup Made Please do not situri Select background perture 1178 502 Clear har karaund picture Room Element Display Doorbell Pos Setup Doorbell Properties Doorbell Lamp Ream Property E Card Lamp Preasa Laundry Ht Pease Sweep 3 Room Name Lamp Universal Switch ID g s O Center mi B es d m JB 8 Ed Please refer to the process shown in step 5 If indirect control is not selected universal switches 1 to 6 can be sent to the doorbell panel This can enable the triggering of laundry DND sweep room name doorbell card lamp Room System Data building Doorbell Setup universal switch 13 18 Subnet ID DeviceID 5 Channel ID of SB DN 48HNET for bell 9 C Modi Indirect Control C it will send out universal switch 1 6 to door bell panel 12 Card issued Issuing a guest room card for Room 1133 Hotel sign HDLHOTEL WEIS Card valid time 2 day 2015 3 25 v 21 15 Card Number 1133 Choose room Building No 1 building lad Floor No 1 floor 1 a Room No 3 1133 Lz BO Connect status Connected indirect control means when SB DN 48HNET rec
48. ms one key card can be authorized to access more than one room Bl Purifier Card lll vender Card Bll Manager Card Connect status Connected New host module and IHMS User Manual 11 User Manual D L HDL MHRCU 433 and IHMS 5 3 4 System Setup P Hotel Multi Lingual Room Management Software V1 08 112 _ E AddRoom Find Room CardWriter Sys Setup Serve Status History UserManage Hide 1 Basic system settings System etup gt M ot Basic etu delte Show Screen Max Screen Tool bar E C Left E Top Right E Bottom Room status inquire Room net information inquire Current room content inquire E Room Setup Protect E Guest card tips 1 Show Screen Allows the size and the position of the IHMS and the Tool bar to be adjusted 2 Refresh Setup Room status inquire Sets the IHMS refresh time for the room status Room net information inquire Sets the IHMS refresh time for the room net information inquiries e g room IP MAC room name etc Current room content inquire Sets the IHMS refresh time for the room currently selected A user can inquire about the AC status lamp status curtain status etc 3 Room data Room Setup Protect If this option is checked a password will be needed when entering the control or setup mode Guest card tips If this option is checked a notification will appear on screen if the guest is currently in the room w
49. n of current key Mode Parameter 2 Paramel On Switch Status Single on off Universal switch 5 Switch no On Switch Status doorbell Single on off New host module and IHMS User Manual 63 User Manual HDL MHRCU 433 and IHMS Parameter 1 Parameter 2 i Universal switch 4 Switch no On Switch Status 16 Setup finished New host module and IHMS User Manual 64 amp User Manual D L HDL MHRCU 433 and IHMS 10 Note New host module and IHMS User Manual 65
50. ne lamp setup 11 9 managed 0 12 9 Managed 0 13 Ignore 14 Q Ignore 15 Ignore 16 9 Managed 0 17 Ignore 18 lamp 18 3 Ignore 19 lamp 19 Q Ignore 20 Ignore 21 Ignore 22 Ignore 23 g Ignore 24 9 Managed 0 0 Second The system allows up to 99 scenes to be created in these scenes lamps air conditioners curtains fans radios and panels can be configured To use Scene Panel Shield Setup the Panel Control Tab must first be set up Scene Valid Enables or disables a scene Scene Output Enables a user to see the scene running when it is being set up Recall a scene Scenes from the HDL MHRCU 433 can be recalled as shown in the below screen shots Recall scene 5 Device 1 107 HDL MPL8 48 FH YY 107 MCI Current key 1 Mode Single on off Input function no from h mw h Key information Te2 112 e p Function configuration of current key 7 Function no Subnet ID Device ID Type Parameter 1 Parameter 2 Paramet Single on off 3 5 Area no 5 Scene no Recall scene 1 Device 11 107 HDL MPL8 48 FH YY 107 v Current key 1 Mode Single on off Key information e all a EE Key no Remark Mode ion no Single on off 33 1 Area no 1 Scene no New host module and IHMS User Manual 39 User Manual D L HDL MHRCU 433 and IHMS 7 7 10 1 Scene and Lamp Setup ccupied gu yest Remarkioc
51. net Hub MHPRCU 433 Roan HMS so vare Spoakor HDL MZDN 432 Spcakor HOL MZ0N 432 1900tc0ble Output cable ACIS ODWEr Etherret Hub EUSO Cable Fao jemet MIIRCW 433 SHCOkKer cable Room New host module and IHMS User Manual 9 amp User Manual D L HDL MHRCU 433 and IHMS 5 Features and introduction to the IHMS 5 1 Login There are three types of user administrator master user and HDL user 1 Administrator This type of user has an unlimited ability to control set up modify and monitor Username admin Password admin default 2 Master User This type of user can monitor and control but cannot set up or modify Username master Password master default 3 HDL User This type of user can only monitor Username hdl Password hdl default Login interface Input account and password Change the language New host module and IHMS User Manual 6 User Manual D L HDL MHRCU 433 and IHMS 5 2 Main Interface YT TT e Userklan ye Hide Tool bar Here first floor has one room 1133 urrent Time 2015 07 00 Sunday 11 13 42 Tool bar a Hotel Multi Lingual Room Management Software V1 08 112 Admin Six Curatin Edition mo S Add Room Find Room CardWriter Sys Setup Serve Status History UserManage Hide Hotel Manage Software 1 Add Room Add a new host module SB DN 48HNET or HDL MHRCU 433 2 Find Room Se
52. nperature 200 High Wind Bl vindsaven ET Tampere 200 md High Wind Bl v naseerp Temperatura HE Bl WindSween Tamnperatura 276 s Low Mind High Wind User Manual HDL MHRCU 433 and IHMS To set the dates for summer and winter please refer to section 5 3 4 Sys Setup Season setup 7 7 3 Curtain tab Room System Data building 1 floor 1 1133 Module Edition Curtain Order 1 Curtain Remark curtain Exist Non existent Non existent Non existent Non existent Non existent curtain ai u Lo mr en 7 Channel Setup Forward channel delay Forward channel Switching on delay 0 3600 Second Backward channel Protection delay 0 3600 Second Running Time 0 3600 Second Backward channel delay Switching on delay Protection delay Running Time Read save Load from device succeed F5 Refresh Current Page Shift F5 Refresh All Pages 0 3600 Second 0 3600 Second 0 3600 Second The HDL MHRCU 433 supports up to 6 curtain motors each curtain motor needs to be assigned 2 channels from the HDL MHRCU 433 One channel is used for forwards and the other channel being is used for backwards Switching on delay Please refer to section 7 7 1 Lamp tab Protection delay Please refer to section 7 7 1 Lamp tab Running time The time the curtain motor is active New host modul
53. nt Non existent Non existent Non existent Non existent Non existent Non existent Non existent Non existent Non existent Non existent Non existent To add a background image or icon to the window right click on the add room background icon or right click on a blank area and then click on select background picture Room Management Software V108 112 Admin Six Curatin Edition o All Rooms building 1 Sue Satin Serve Stat Sys Set erve Statu NL building 1Mfloor 111133 UE Vacancy floor 1 Reserved n 2 Checkin 4 floor 3 Out Of Servic Current Time 2015 02 11 Wednesday 16 16 29 SIO MDL Hotel Manage Software Refresh Show Mode Control Mode Setup Mode Add Lamp Select background picture 1178 502 Clear background picture Room Element Display Set Start channel of affiliated module Enable Switch Function Room System Data New host module and IHMS User Manual 22 User Manual i D L HDL MHRCU 433 and IHMS 7 4 Enable the Switch Gateway function To enable the switch function of the HDL MHRCU 433 the switch icon must first be selected The HDL BUS Pro Setup Tool will now be able to access the HDL Buspro system via the HDL MHRCU 433 room host module amp To enable debugging click on the above icon to enable an unrestricted data flow Once the interface is exited the two switch icons will revert to being inactive This is a
54. nual 56 User Manual amp D L HDL MHRCU 433 and IHMS Curtain Open az imi Ate Scene Setup Scene ID1 Scene Remark moar ED a Scene Remark check in null osmero Bl Scene Output FCU Cooling amp high wind amp 20 New host module and IHMS User Manual 57 User Manual D L HDL MHRCU 433 and IHMS Veritilation Fan Order 1 E ventiaton Fan Senn Venttaton Fan FAN Doorbell The room name lamp and the card lamp on the doorbell panel are on DOM 1 check in null check in null Doorbell Setup universal switch 13 18 Display scene number 0 99 1 3 check in null Managed 5 Managed 1 Managed 1 Managed 1 Ignore Managed Ignore 2 3 vacancy Managed 5 Managed 1 Managed 1 Managed 1 Ignore Managed Ignore 3 3 reserved null Managed 5 Managed 1 Managed 1 Managed 1 Ignore Managed Ignore 4 3 occupied guest Managed 5 Managed 1 Ignore Managed 1 Ignore Managed Ignore 5 3 occupied null Managed 5 Managed 1 Managed 1 Managed 1 Ignore Managed Ignore 6 3 waiter Ignore Managed 1 Managed 1 Managed 1 Ignore Managed Ignore 7 8 Q9 9 Q 10 FJ New host module and IHMS User Manual 58 User Manual D L HDL MHRCU 433 and IHMS 8 Scene Status Select the room status scene ta EXE 1 fl 1133 Mod le Edit dition Me ood actuosa Vacancy Null Card 2 v
55. omae NE 50 ENN RR 50 IO DINGO m ec 51 VNR 65 New host module and IHMS User Manual amp User Manual i D L HDL MHRCU 433 and IHMS 1 Overview 1 1 General Information 1 1 1 Description of the IHMS The IHMS Intelligent Hotel Management software also called GRMS Guest Room Management Software is a hotel management software developed by HDL which combines the powerful hotel host module SB DN 48HNET HDL MHRCU 433 and its affiliated module SB DN HMIX20 SB DN HMIX18 etc The IHMS is capable of controlling monitoring and managing lamps ventilation fans ACs curtains door bells check in check out house keeping information and SOS alarms etc 1 1 2 Description of the HDL MHRCU 433 The core of the HDL hotel system is the HDL MHRCU 433 hotel room controller module The module is capable of mix control doorbell status display 24 channel dry contact output and LED output In total the hotel controller has 48 channels and can be programmed from the hotel management software The module can control and monitor doorbell panels 3 party s doorbells curtains lights fans and air conditioners 1 1 3 Mounting the HDL MHRCU 433 Ca 20 19 18 IF ili 1 90mm MEER UE 5 j i LO C 35mm h dH I l
56. or button panel that sends universal switch numbers 13 18 to the HDL MHRCU 433 When HDL MHRCU 433 receives Universal Switch 13 18 it will send out Universal owitch 1 6 to doorbell panel Third party normal doorbell control Third party normal doorbell control is used to control doorbells from other manufactures that do not have native automation connectivity Please refer to section 7 7 11 Doorbell tab for further information New host module and IHMS User Manual 34 User Manual D L HDL MHRCU 433 and IHMS Card Reader Setup Card Reader Setup Universal switch 1 ON Card Reader E Card Reader Type Card Reader a Subnet ID 1 Device ID 103 Came Save Card Reader Dy Contact Dry Contact Fu O Modiy If a keycard is used to open a hotel guestroom door the key can be placed into a card reader module This card reader can then cause the power to be activated or preset scenes to be triggered the scenes triggered are dependent on the keycard type and card reader settings If the card reader is set as a Dry Contact the HDL MHRCU 433 and IHMS software will register a guest key card as being inserted when universal switch 1 on command is received When the universal switch 1 off command is received the system will register the keycard as being absent FM Setup If a room has a FM panel installed its device ID must be input FM Subnet ID 4 Device ID 1 Custom
57. please refer to section 7 7 10 Scene tab New host module and IHMS User Manual 19 User Manual D L HDL MHRCU 433 and IHMS 7 2 HDL Doorbell iControl Mode building T 141133 Urgent Null This shows that the room card has Vacancy not been inserted into the room card reader Reserved ME A 15 A Shows the room number eckin Se To simulate the presence of a room card use the Control Mode and then right click on the doorbell icon us Refresh Show Mode 4 Control Mode Setup Madre sene k Panel Shield L Lirgent Card Status F Fart Card Status Room Property Urgent Hull Urgert Guest Card Urgent Waiter Card Urgent Purifier Card Urgent Mender Card Urgent Manager Card To setup a doorbell go to the Setup Mode and right click on the door bell icon ry Ww building 1 floor 111133 Out Of Service Uke Var ru Vacancy 4 Vn AA s UP Please Wait is Please Laundry B lad Show Mode Control Mode v Setup Mode Please do not disturb 4 v Please Sweep 2 x Select background picture 1178 502 Clear background picture Room Name Lamp 4 Room Element Display Doorbell Lamp 5 Doorbell Pos Setup Doorbell P rti r roperties Bl Card Lamp Room Property To control a doorbell please refer to section 7 7 6 Other tab New host module and IHMS User Manual 20 User Manual D L HDL MHRCU 433 and I
58. room lights is off Leading edge dimmable lights Bedside light and reading lights are both turned off Curtain No change FCU Cooling amp low wind amp 25 Ventilation fan Open Doorbell The Room name number and card icon should be illuminated 5 When the room is Occupied null card Lights Wall light down light and bathroom light are off Leading edge dimmable lights Bedside light and reading lights are both turned off Curtain Closed FCU Off Ventilation fan Off Doorbell The Room name number and card icon should be illuminated 6 When the room is Waiter card New host module and IHMS User Manual 52 amp User Manual D L HDL MHRCU 433 and IHMS 7 Wiring Room 1133 Lights Wall light down light and bathroom lights are unchanged Leading edge dimmable lights Bedside light and reading lights are unchanged Curtain Open FCU Off and lock the AC page of DLP Ventilation fan Open Doorbell The Room name number and card icon should be illuminated When the room is Out of Service the settings are the same as when the room is vacant Lights Wall light down light and the bathroom lights are all off Leading edge dimmable lights Bed side light and reading lights are off Curtain Closed FCU Off Ventilation fan Closed Doorbell Only the card lamp on the doorbell is illuminated staff can still access the guest room Other When the guest exits the room a delay time of 1 minu
59. rrnrrrnrrrerrarnenrannenrnnrenrnnrenrnnnenrnnnennnnnnennnnennnnee 6 SEE EN 6 2 2 ET 001 EE E E A E E E EUER UEM ee T STOR T AR aeann Aa AEA EREA UEM E T oo Sa FNA ROOM PER ERIT 9 PO iMm em 9 95 93 4 System NL 12 5 3 5 SAVE SAUS Lade 15 SJ eg EEE UU UO EUIS 16 5 3 7 User Management rrrnnnnnnnnnnnnnnnnnnnnnnennnnenvnnnennnnnennnnnennnnnnnnnnnennnnnennnnsnennnn 16 500 FU Ja 17 SE t eee eee cen eee meer E ner 17 OI 17 6 2 Add a background IMAGE ccceecccceeeeeceeeeeceeeecaeeesaeeeeaeueessaueessaueesseeeeesaneeenaes 18 6 3 Room Description and Alarm Prompts ccccccecsececeeeeeeeeeseeeeseeeseeeesaeeesaeeees 18 71 Room Management ccccccceececceeeeeceeeeeecueeeeeueeceeeeesseueessueeeseueesseueeeseeseesseneesseeeessees 19 7 1 Current POI Status eee 19 GZ 2 800 ON EE E E S 20 FRON MT 21 7 2 Room Element Display rrrrnnnnnnnnnnnnnnnnnvnnnrennnnnennnnnennnnnennnnnennnnennnnnennnnnsennnsnennnn 21 7 3 Add a Room Background Image rrnnnnnnnnnnnnnvnnnnennnnnennnnnennnnnennnnennnnnennnnnennnnnennnnn 22 7 4 Enable the Switch Gateway function rrrrrrnnrrrrrnnnnevrnnnrernrnnnrrnrnnnnrenrnnerennnnnsnne 23 7 5 Set a Start Channel for an Affiliated Module sseeessseesss 23 TPM 25 7 7 Setting room system dal a rrr trn teen vore ux a o pn
60. served EJ invalid Notice Thief gg ignore EJ Checkin EJ Guest Card Notice Help EJ ignore EJ Occupied EJ Waiter Card Notice Door Eg Ignore EJ Out Of Service EJ Purifier Card Serve One g ignore EJ Mender Card Serve Two Eg ignore EJ Manager Card Serve Three gg ignore Rooms can be found by either inputting the room name s or through filtering via search parameters conditions 5 3 3 Card Writer The card writer is used to program room cards for customers and housekeepers etc To program a card first select the card writer icon fa Hotel Multi Lingual Room Management Software Vi08 112 C E Add Room Find Room CardWriter Sys Setup Serve Status History UserManage Hide Card writer with USB terminal New host module and IHMS User Manual 9 User Manual HDL MHRCU 433 and IHMS The driver for the card writer can be found under the installation path for the IHMS the driver is named USB Card Writer Driver Driver installation steps 1 Connect the card writer to your computer and install the USB driver My computer properties gt device manager universal series bus controller gt the new connected USB right click and select update driver software Em System T D amp Conti Panel Sytem and Security System wis Sane Control Panel Home ped xs Viewer basie informatie fie Action View Help Mj Device Manager West eden y Bem te tetta Winders E 1 gt gid DVD CD ROM di
61. stent 4 Non existent 5 Non existent 6 Non existent Curtain Order 1 Remark curtain i Curtain Close Bl Curtain Stop In Scene 5 occupied guest card the curtain has been set as managed and open New host module and IHMS User Manual 41 User Manual D L HDL MHRCU 433 and IHMS 7 7 10 4 Scene Ventilation fan Setup Scene Order 5 occupied guest cdg Scene Remark occupied guest car Ventilation Fan Setup ventilation fan Non existent Non existent Non existent Non existent ne wh EXIT Ventilation Fan Order 1 EJ ventilation Fan Setup Ventilation Fan ventilation fan Managed EJ ventilation Fan Open lll ventilation Fan Close In Scene 5 occupied guest card the ventilation fan has been set as managed and open 7 7 10 5 Scene FM Setup Scene Order 5 occupied guest ca Scene Valid Scene Remark occupied guest car Save To lll Scene Output Please set FM before The FM panel settings have not been set in the Other Tab so the FM function is unavailable For further information concerning the FM panel please refer to 7 7 6 Other tab New host module and IHMS User Manual 42 User Manual D L HDL MHRCU 433 and IHMS 7 7 10 6 Scene Doorbell Setup Scene Setup Scene ID 5 Scene Remark occupied guest ca s des Scene Order
62. switch 2 ON Trigger Check out tips OFF Cancel Check out tips Thief universal switch 3 Help universal switch 4 Service One universal switch 6 Service Two universal switch 7 Service Three universal switch 8 Camera universal switch 9 Load from device succeed F5 Refresh Current Page Shift F5 Refresh All Pages Timeout of opening the door universal switch 5 This function is used to warn the end user if they have left a door open and not inserted the room card into the card reader module In the above screen shot the settings show that when the HDL MHRCU 433 receives a universal switch 5 ON command a five second countdown will begin If the HDL MHRCU 433 does not receive a universal switch 5 OFF command and the time elapses channel 9 will be turned on and off alternatively ON 1s gt OFF 1s gt This can be cancelled by sending the command universal switch 5 off to the HDL MHRCU 433 or inserting the card into the card reader module Universal Switch The universal switch tab displays the universal switch commands that the HDL MHRCU 433 has received When a customer request is received a report is sent to the IHMS software The usual method of sending a universal switch command to the HDL MHRCU 433 is via a panel As an example if a guest uses the DLP panel to check out the reception can receive a notification A To enable the check out notification open the DLP settings in HDL BUS Pro Setup
63. te should be activated When the delay time has elapsed the occupied null card scene will activate E i Y P T h 25 EST AL ET Tl FEN Pah ri Fu nl d E T Outou E E EX a X Duo cabe Fit amel amp User Manual D L HDL MHRCU 433 and IHMS Setup Detailed system setup steps are shown in the below screen shots 1 Add Lights Assign channels 14 15 16 to the wall light down light bathroom light Assign channels 18 19 to the bedside light reading light Batch Add Bl Batch Add Information Channel ID 44 mM i ightness 100 Time 0 Second Icon Information osse ed Faustovi Bxavemevd a s 3d Left 0 Top 410 Width 60 Height 60 Remark wall light Channel ID Batch ID Font Arial I Font Size 14 Text Left 30 Text Top 30 etc ie Vacancy Reserved N D Checki dar x eckin u L t E E Out Of Service wall light down light bathroom light bed light reading light 2 Add AG Assign channels 1 5 for AC then add a valid AC panel controller New host module and IHMS User Manual 54 User Manual D L HDL MHRCU 433 and IHMS Air Conditioner Order 1 Air Conditioner Remark central AC Mode Open Detay 3 3 325 5econ ii Mode Close Delay 1 1 10 Second fan Open Detay q 1 T0 Second fan loge Delay 1 1 i amp acond Lee fram sth sucre Es Rotesh Coren Page Shiners P
64. ual HDL MHRCU 433 and IHMS admin Admin Adminstrator master Master Master User hdl User User EJ auto Login Auto Login User admin Language English With User Accounts admin an IHMS software user can be added deleted or modified Auto Login If the Auto login feature is checked the IHMS software does not require a password on initiation 5 3 8 Hide fa Hotel Multi Lingual Room Management Software V1 08 112 Admin Six Curatin Edition To BR o i Add Room Find Room CardWriter Sys Setup Serve Status History UserManage Hide If the hide icon is selected the IHMS software window will be minimized 6 Setup 6 1 Add Room See Section 5 3 1 Add Room New host module and IHMS User Manual 17 User Manual D L HDL MHRCU 433 and IHMS 6 2 Add a background image Fay Hotel Multi Lingual Room Management Software VLOKIIS Admini Curatin Edition MM HO TE Add Room Find Room Carndwrmer Sys Setup Senet Statu All Rooms buildmg V g 1 Page 1 HANG 1 Bn Rooms EC Bane ph Poor rt iil Bn z B Add Room Add Umconnect Room Refresh Select background picture 105387567 Clear background p rture Sort by room name Cuncnt lime 2015 02 09 Monday 20 03 40 To add an image to the background of the hotel management software right click the blank area and then select your chosen image picture 6 3 Room Description and Alarm Prompts Fy Hotel Multi