Home

- Citygrow Energy Systems

image

Contents

1. q 6 Specification Description AC Socket UK China AC Socket USA Load current A 13A 10A Power supply voltage AC220 to 240V 50HZ AC114 to 126V 60Hz Two way control function YES YES RF frequency 2 4GHZ 2 4GHZ Remote control distance M line of sight 100M 100M Dimensions mm Length x Width x Height 115x87x46 117x70x44 Recommended operation temperature 0 to 40 degC 0 to 40 degC
2. that the CG100SK is awaiting confirmation of the binding process STEP 5 Press and release the desired ON OFF Button once to confirm the binding STEP 6 Binding is complete Ensure the binding was successful by using the Remote or Panel to control the CG100SK NOTE The maximum number of Panels the CG100SK can be bound with is 8 Any additional Panels will not receive any status feedback from the CG100SK 5 Clear Memory Clearing the memory inside of the CG100SK will result in 1 The CG100SK will no longer reply to any Panels that it had previously bound to 2 The CG100SK will no longer reply to any Remotes that it had previously bound to User Manual of CG100AS q In order to perform the Clear Memory function please follow the below steps STEP 1 Press and HOLD the ON OFF Button STEP 2 CONTINUE holding onto the ON OFF Button Press and release the Reset Button once STEP 3 Wait until the LED Indicator begins BLINKING Release the ON OFF Button STEP 4 Press and release one of the ON OFF Buttons again to stop blinking User Manual of CG100AS STEP 5 Press and release the Reset Button The memory inside of the CG100SK has now been cleared The above section 3 and section 4 applies to CG100SKCN and CG201SK User Manual of CG100AS
3. ACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the product IMPORTANT SAFETY INSTRUCTIONS READ BEFORE OPERATING EQUIPMENT This product was designed and manufactured to meet strict quality and safety standards There are however some installation and operation precautions which you should be particularly aware of SOG NS 11 12 13 14 Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus that produce heat Do not defeat the safety purpose of the polarized or grounding type plug If the provided plug does not fit into your outlet consult an electrician for replacement of the outlet Protect the power cord from being walk
4. CG100SK CG100SKCN CG201SK AC SOCKET USER MANUAL CG100SK CG100SKCN CG201SK AC Socket AC Socket AC Socket UK China USA VERSION 1 0 21 JANUARY 2013 PRELIMINARY CityGrow Systems Disclaimers and Copyright Nothing contained in this publication is to be construed as granting any right by implication or otherwise for the manufacture sale or use in connection with any method apparatus or product covered by letters patent or as insuring anyone against liability for infringement of letters patent Efforts have been made to ensure the accuracy and reliability of the data contained in this publication however Citygrow Energy Systems Limited makes no representation warranty or guarantee in connection with this publication and hereby expressly disclaims any liability or responsibility for loss or damage resulting from its use or from the use of any product or methodology described herein for any violation of any federal state or municipal regulation with which this publication may conflict or for the infringement of any patent from the use of this publication Nothing contained in this publication should be viewed as an endorsement by Citygrow Energy Systems Limited of any particular manufacturer s products Copyright 2012 Citygrow Energy Systems Limited All Rights Reserved User Manual of CG100AS RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR B
5. ed on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufacturer Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over Unplug this apparatus during lightning storms Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped User Manual of CG100AS O Table of Contents IMPORTANT SAFETY INSTRUCTIONS sc ceccccacssacctaestanceecsssectacstescarecisestaasaegetneceacstraraeteus i Ai TEP OMMICTION isciani E TA 1 2 gt MMSEANAUOA ssaa AAA AaS 2 Bs Getting Started E 4 dio BINGO S aeea AE E E EE EE E 5 5 Clear Memory s esessssrsssssrssrsosssrsersonsssnserrosssensnrssrsossnrssnsossnenenrosnsensnresnsonsnreennoe 6 6 Specificato asss a a E A E EEEa 9 1 User Manual of CG100AS O Introduction Thank you for choosing Citygrow s product The CG100SK CG100SKCN CG201SK is AC Socket which is designed for wireless control use The CG100AS CG100AS01 CG201AS works on ZigBee and can be wi
6. relessly controlled by Citygrow s remote control or control panel products Description 1 2 8 9 ZigBee wireless remote control Based on IEEE 802 15 4 2 4GHz radio frequency DIY plug and play AC 220V 13A for UK China version AC120V 10A for USA version LED backlight indicator for on off status Local on off button Support iPhone iPad and Android mobile control if CG102BS Base station is purchased 10 Control button graphics can be tailor made per customer requirement 11 No EIB Bus required 12 Easy to install User Manual of CG100AS 2 Installation In order to install the CG100SK correctly please follow the below steps Please note for CG100SKCN the installation follow the same steps described below For USA version AC socket CG201SK the installation follow the same steps except that a USA wall box should be used STEP 1 IMPORTANT Turn off main power at the main switch board ONFONIONJONY ONIONIONI JONION FERRE Eee B3 OFFPFFPFFPFFE JOFFPFFPFFRE FOFFIOFA STEP 2 Loosen the screws of the original AC Socket Remove the AC Socket and disassemble to access the Live Neutral and Earth wiring STEP 3 Connect the Live Neutral and Earth terminals at the rear cabinet of the device Earth Neutral User Manual of CG100AS OSY gt ems STEP 4 Fasten the screws of all terminals and check that the wires are properly secured Install the AC power socket on the wall by fastening
7. the two screws Install screw x2 Fuse Reset STEP 5 Push the ON OFF Button test whether the wiring has been connected correctly If the ON OFF Button does not function as expected please check the wiring connection again User Manual of CG100AS g 3 Getting Started COVER PLATE 1 1 Door Slide to Open 2 ON OFF Button 3 LED Indicator MAIN UNIT 4 Connector 5 Screw Holes 6 Fuse 7 Reset Button N DO wast 1 Press ON OFF Button once to toggle between ON and OFF LED ON indicates the Socket is OFF LED OFF indicates the Socket is ON User Manual of CG100AS q 4 Bindings The CG100SK can be bound with Citygrow s Remote products as well as Control Panel products to allow for wireless control In order to perform the Binding function please follow the below steps STEP 1 Connect one end of the provided USB Cable to the CG100SK and the other end to a PC STEP 2 An ID must first be programmed into the CG100SK Refer to the User Manual for the HomeNET Planner software for instructions on how to do so STEP 3 Unplug the USB Cable from the PC and plug into a Remote or Panel To begin the process of binding to the CG100SK please refer to the User Manuals for the Remote or Panel products User Manual of CG100AS STEP 4 When the LED Indicator begins BLINKING this shows