Polyrack Präsentation - Buddy
Contents
1. Charging Adapter 1 Ultra Sound Sensor 2 Functions Button lt gt 3 Call Button 3 8 ier _ 4 Battery Charge Indicator 6 5 Display with Distance Indicator 6 6 Arm Wrist Band T Charging Port amp Water Contact Quick Manual Manual online Download 8 UCS Port Charging Adapter i 9 UCS Port Charging Cable 11 10 USB Port Charging Cable 13 Short Manual 2 Wamings BUDDY IN The main danger using the Buddy Watcher is the exaggerated trust in the functions of this product As an electronic system sudden and unexpected malfunctions related to components battery or software errors may Occur This is a device based on acoustics and it can be circumstantially fault out due to a changing acoustic environment Please take note of the following Warnings for the Buddy Watcher e Use the Buddy Watcher only according to this Manual e Never dive alone The Buddy Watcher does not relieve you of your Responsibility for your Dive Buddy according to the generally known Safety Standards e Buddy Watcher is Equipment e The device has been designed to a depth of maximum 40 Meters and may only be used in salt or fresh water e The Buddy Watcher may only be used by professionally trained Divers and does not replace professional schooling for Divers no personal Safety Under no circumstances does the Buddy Watcher relieve the Divers of the use of a proper Buddy Line where it wo
2. recharged latest after 4 days 5 Startup Instructions 2 Wee Press for JE f 5 seconds ATTENTION Disconnect your device from any power source prior to use How to attach Buddy Watcher e Pull the Arm Band through the loop Pic 1 e Put your Hand through e Pull the Buddy Watcher with the Arm Band until tight and fasten it with the velcro fastener Turn on Buddy Watcher e Press the large Calling Button for 2 seconds to turn on the Buddy Watcher Reset and Turning off e The Reset Button shuts down the Buddy Watcher and turns it off e Press the Calling Button and the Functions Button both at the same time for 5 seconds Pic 5 Functions Check e Device is turned on when all LED are lit up and a short Vibration confirms it being on Abb 3 After 3 seconds only the battery light stays on This is the Start Mode Check Battery Charge e If all 3 LEDs stay on continuously you may dive Pic 4 e If the left 2 LED stay on continuously you may dive e If the first left LED stays on continuously max 1 dive is advised Charging is recommended e Ifthe left LED is blinking the battery needs recharging and the Buddy Watcher should be charged 6 Functions gt BUDDY The Buddy Watcher only functions within the System i e prior to diving two Buddy Watcher have to be synchronized with each other Coupling Synchonization may be done in or outside of the water Outside of the wat
3. Communication System for Divers Prologue We believe that our loved Hobby Diving with the Buddy Watchere is a lot safer Too many diving accidents are being broadcasted and most of them happened because the communication between the diving partners broke down WARNING The Buddy Watcher does not prevent accidents It also does not relieve the diver of the responsibility for their dive partners according to the generally known Safety Standards Buddy Watcher is a supporting Assistence System for Diving It ensures the continuous contact between the Buddy Team It is easily fixed to the arm or wrist and is intuitively operable The Buddy Watcher is the fastest and simplest method to call your own Buddy under water from a distance of up to 20 Meters Buddy Watcher is the only communication device that calls or vibrates only for the relevant Dive Buddy and with that ensures a much more relaxed and comfortable experience under waiter WARNING For your own safety please read all instructions in this manual and guides provided for the Buddy Watcher completely and carefully Dive Diver calls Buddy Diver communicate Content 1 Box Contents 2 Warnings Se Signals 4 Prior Use O1 Signals 6 Startup Instructions 7 Functions 8 Maintenance and Service 9 Intellectual Property 10 Technical Data and Equipment 1 Assembly and Box Contents gt BUDDY Buddy Watcher
4. conds The Calling Function only works within 20 Meters distance under water Master Calling Press the Function Button Pic 2 on your Buddy Watcher e Einmal die Funktions Taste Abb 5 drucken um Signal beim Masterger t auszul sen e IMPORTANT an coupling synchonization with the master device is not needed 7 Maintenance and Service Cleaning e The Buddy Watcher should be washed after every use with fresh water e Do not use detergents or chemicals e Make sure all components including the arm band are completely dry before storage Replacement Parts e In cases of damage the components such as Arm Band Charging Adapter Charging Cable etc may be ordered on http shop buddy watcher de e Changing the battery should only be done by the manufacturer Free Linked GmbH Repairs WARNING Opening the Buddy Watcher will destroy the device This will void all warranties and liabilities e Repairs should always be done by the manufacturer Free Linked GmbH Warranty The company Free Linked GmbH will guarantee the product Buddy Watcher for two years from date of purchase according to the sales receipt in case of material and manufactural faults Wear and tear on components such as Arm Bands are excluded from this warranty The warranty will cover repairs or replacements of components free of charge The Warranty is only valid in the following cases e The Warranty only applies to first time buyers e T
5. er reaction times may be delayed Hold the Buddy Watcher in such a way that both sides of the sensors are facing each other Pic 1 e The coupling function is only possible within immediate proximity max 15 cm e Please make sure that no other Buddy Watchers are located within 1 m Buddy Watcher initializing Coupling e Press the Function Button Pic 2 on your Buddy Watcher for at least 3 seconds This will establish this Buddy Watcher as the Master device The LEDs on this Master device will start to blink As soon as on the Slave device Pic 3 all 10 LEDs start blinking the Slave Buddy Watcher must confirm the coupling with the Function Button for ca 2 seconds e The coupling process is finished when both Buddy Watchers confirm this with a short vibration and only the battery lights are on 3 e If no Vibration can be felt please repeat Coupling Synchronization process my m AN If no coupling took place the Buddy Watcher will remind the diver after 5 Min with one short 7 BIOS m vibration to repeat the coupling synchronization process This can be done under water the same A A way as described above 6 Functions BUDDY er Calling Press Calling Button once Pic 4 to send the signal e A short Vibration and 10 blinking LEDs confirm the call e The Buddy feels the Vibration 3 x long and the left and right LEDs will blink alternating e A second Calling is possible after 30 se
6. he Warranty cannot be transfered e The Warranty only covers material and or manufacturing faults The device was used and handled appropriately according to the guidelines pro vided e The Warranty and any liability is null and void in cases of misuse neglect damages or unauthorized repair attempts 8 Intellectual Property Buddy Watcher The Brand Buddy Waitcher is under copyright in all of Europe under No 009733494 The Buddy Waicher has been patented under 10 2012 100 679 2 User Manual The User Manual is the intellectual property of the Free Linked GmbH and under copyright Online User Manuals as a whole or parts of it may not be copied reproduced and or distributed without any consent of the Free Linked GmbH 9 Technical Data Technische Daten Display LED rot 13 Eingang Ladegerat 100 240 Vac 0 2 A 50 60 Hz Ausgang Ladegerat 5 Vdc 850 mA Akku Li lon 3 7 V 900 mAh durch Verbraucher nicht wechselbar Maximale Ladedauer Ah Einsatzdauer nach Vollladung max 6h die tats chliche Einsatzdauer ist abh ngig von der Temperatur und Nutzungsalter Lagertemperatur ca 20 C Einsatztemperatur 0 C 50 C Maximale Einsatztiefe 40m Messgenauigkeit 0 5m Maximale Reichweite unter Wasser 20m Messintervall 0 8 s bertragungstechnik Ultraschall 60 70 kHz Abmessungen ohne Armband 3 6 cm x 7 2 cm x 8 5 cm Gewicht 102 g
7. s Long Vibration ca 2 s 3X Short Vibrations 3X Long Vibrations M M 1 i V aL 2 LED _ 2 LED 10 LED 10 LED lights uiz lights lights lights 4 Prior Use o RE ATTENTION Water and Electricity should not ever touch each other Please ensure that all device components are dry during charging 1 er Prior to first use the Buddy Watcher should be charged Br Way e Use the standard Charging Adapter Pic 1 ER TE e The Charging Adapter should be placed onto the Buddy Watcher Please make sure that the round opening sits above the sensor The flexible Charging Adapter will engage and latch on Pic 2 Charging e Connect the standard Charging Adapter and the USB Cable to a Charging Station Pic 3 Alternatively the Buddy Watcher may be connected to a PC or charged in the car Charging Process e As soon as the Battery Light in the Display comes on the LEDs will light up Pic 4 The Charging Process is finished when all three LEDs are on Loading time ca 4 hrs e With a fully loaded battery the Buddy Watcher should last for up to 6 general dives 7 X WARNING Low Temperatures may reduce the battery power to up to 70 Frequent charging of The battery is beneficial this is why the Buddy Watcher will discharge to 40 power which DD Ladevorgang Aufgeladen makes the Buddy Watcher inoperable and will have to be
8. uld be necessary according to the general Safety Standards such as for diving under ice etc The Buddy Watcher was designed for the useunder water and for the sport of diving Using the Buddy Watcher in Swimming Pools Caves or similar highly reflecti ve diving areas may interrupt communication Communication may be influenced or interrupted by walls and or rocks and or obstacles and barriers After use the Buddy Watcher should be thoroughly cleaned with fresh water only do not use cleaning detergents Do not use parts and or components which are not authorized recommended or coming from the original manufacturer themselves Do not charge the Buddy Watcher in the blazing sun explosion Do not throw the the Buddy Watcher into open flames danger of explosion danger of Prior to Charging the Buddy Watcher and Adapters should be dry and clean The Buddy Watcher may influence compasses and change directions The Buddy W atcher may lead to signal errors and or failures in other devices Batteries are not to be disposed off in normal household waste By law Batteries should be professionally disposed Batteries may be returned to the store or place of purchase after use and or being brought to special collection services in stores and the post office at no extra costs 3 Signals o RRR Beispiele Vibrationssignale Short Vibration lt 1