ETH Adapter CN USER MANUAL

image

Contents

1. 26 TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR JU FF FOURSTAR Electronic Technology Co Ltd De Yang China 2 PC work as Client ETH Adapter CN work as Server TCP Server S7 300 400PLC WAN Internet TCP Client TCP Client You also could set ETH Adapter CN as server set VCOMM of PC as client you need a router on the side of ETH Adapter CN which supports dynamic domain name DNS in order to avoid the high cost of application the fixed IP address from the local Internet operators and this router is very common now please notice the instructions on the package when you purchase it The router with DNS function need to be installed on the side of ETH Adapter CN and need to set the port simulation for ETH Adapter CN on the router also could connect a PC with the router which is connected with the ETH Adapter CN to run the software to resolve the domain name You could directly input the domain name of remote host when the VCOMM software work as the client support DNS resolution Enter the dynamic DNS setting interface of router input the user name and password of the Dynamic DNS which you applied as shown below then you can find our domain name fourstar vicp cc is connected successfully sF TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR JU FF FOURSTAR Electronic Technology Co Ltd De Yang China zh RRDWSIS MR Ur
2. LT MIN NNN LA PS Se a pom ES FREE Of course you can use ETH Adapter CN to simulate each PLC as a COM port on the PC in order to achieve the data communication and monitoring operation between PC and multiple PLC s 8 Remote communication in the internet ETH Adapter CN can achieve the worldwide remote communication through the Internet it will use the external network IP address of the router the router external network address is different when the router is started every time because the router will be randomly assigned to one IP address from the Internet when it s powered every time so this will result in trouble for remote communication through the Internet There are two following methods to solve this problem Ija TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR EF FOURSTAR Electronic Technology Co Ltd De Yang China Apply to buy a fixed IP address from the Internet operators the fee will be higher Use the domain name resolution you can apply for a free or paid domain name from dynamic domain name service provider then use domain name instead of IP address so that regardless of changes in IP address domain name will point to IP addresses in real time like as we usually visit the website Some providers such as peanut shells and other dynamic domain name DNS service providers offer free and paid dynamic domain name service you can consult them for their dynamic dom
3. V6 1 OSPOYO50125R System Uptime Double click the ETH Adapter CN pop up dialog box enter your user name and password to enter the setting interface The factory default setting Username admin Password admin Login Username admin Password tt pamar Click Login to enter the configuration interface You must firstly click OK to effect the revised parameters parameters not saved at this time after you revise the parameters in every interface then finally click the Apply Settings Restart to save parameters and restart the ETH Adapter CN to work with the new parameters and then exit the setting software As shown below oe TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR BF FOURSTAR Electronic Technology Co Ltd De Yang China Basic Setting J Obtain automatically User config Password setting apply Settinss Rest nr REE Log Out 2 F p 255 255 255 0 HA hbapply bettings Restart RESHHE SBR ees Lie Pr eg BB DNS AR 5 2 EAC Hh ht 202 98 96 68 OO fO Oa 02 ee Tf e ee EE ADI RS 2 Kl 61 129 2 69 PE 1 001 TEEN Full Sr S oR Pe pA FE ete a T H RRG 4 FEE Refresh Close About the parameters configuration details please read the Device Manager Parameters setting software manual After you configure the ETH Adapter CN parameters you need to run VCOMM virtual serial port software on the P
4. the router to access Internet then this step can be omitted TP LINK Windows Internet Explorer Gg http 192 168 1 1 WHP REED 2M NEA LS 8 H w ran O TP LINK Crogieercit tik Si Beth ARS es EIES ee TT dekh AR SS om O AR ARS 2s 0 IIIA Ate ike FS CBS WG ps Be hee ALI ee A ethos ARS m ARO ip fk e RE fe AT Ase BA eA As BARRY MHRA AS A DMZ 4 The meaning of the above settings is that when the client ETH Adapter CN visit and access the router s external network IP address of PC this address is automatically resolved by the domain name you no longer cares about its change router will automatically transfer this visiting to the VCOMM virtual serial port software on the PC with IP address 192 168 1 108 port 8000 which is connected to the router Jda TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR JU After setting click Restart Router button or re power the router to work with the new parameters Run the client software on the PC as shown below the domain name fourstar vicp cc has been pointed to the external network IP address of the router fet e008 asa T Gr lich EE tee er fourstar vicp co Peanuthull clent 5 1 0 1 EE ERE fourstar vicp cc AE 49 MDNSERS 3 nsl oray net fourstar dy gicp net 15 MDNS ES PIL 61 152 96 118 amp fourstar vicp cc HERE MIP 118 124 50 133 Sa Ml ERAS CAVE tie PILER 4 IT p a
5. HES 5 192 168 1 1 Apply Settings Resi 10 Log Out AANS RS 3 MAC Hat 218 6 200 139 00 fO Qa 02 ee Th amp Arn RS 2 Eis bei 6 61 139 2 69 a ba TIPA Basic setting 2 Netvork Channel 2 Pes Bh Server 3 Channel2 ee a Hostlist2 FETIP 0 Hg fF Ox aerial de FNO pus AAEE 1800 Flush Input Buffer As Tt tg PREPARA ah wie PLP MO A Flush Output Buffer Barto i 255 Bl Set VCOMM virtual serial port software parameters on the remote PC select VCOMM as Client working mode choose to use the device detector to create the virtual port 29 TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR JU FF FOURSTAR Electronic Technology Co Ltd De Yang China BEE VCOMMERL LS A fee VCOMMIB T eServer fr see iT eClient itet OUP tert Create the virtual serial port COM3 input the domain name fourstar vicp cc in the remote sever IP address box input the local port No of ETH Adapter CN 27011 in the remote server monitoring port box EMEDIEE TCP IP st SBOE RO 0018 ar I REMRABIPML fourstar vices v MAHR Client Ei v THE X WA Click OK and exit the software and re run VCOMM the client VCOMM will take the initiative to build the connection with the server ETH Adapter CN Then it will create a new serial port COM3 after establishing the conne
6. Network cable is not plugged in no Extinguish No data transceiving Ethernet interface RJ45 socket signal array Positive phase Ethernet data sending Output differential signal line forl negative phase Ethernet data sending Output ma differential signal line Furl Tx Tx Rx Positive phase Ethernet data receiving Input differential signal line Rx C Nous oS C Nouse OOOO o Input Negative phase Ethernet data receiving differential signal line 8 now Default Button Restore the default setted parameters Insert the penpoint into the hole to press the button for about 1 second the internal Flash memory parameters will restore to factory default parameters IP 192 168 0 250 Username admin Password admin When you forget the IP address user name or password you can restore to the factory default parameters and then reset the parameters DP MPI interface DP MPI interface is the DB9M pin plug which meets the Siemens PROFIBUS and MPI interface technical specifications the signal array match S7 300 400PLC interface and has a 0 5 meter cable you just simply plug the DB9M of ETH Adapter CN directly into the S7 300 400PLC MPI or PROFIBUS interface outlet DP MPI plug DB9M pin signal array NC M24V 24VDC power negative LIG B RS485 signal positive Input Output sTo TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR JU FF FOURSTAR Electronic Technology Co Ltd De Y
7. to 176 F 5 to 95 RH sie TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR JU FF FOURSTAR Electronic Technology Co Ltd De Yang China The network type and fieldbus communication baud rate which ETH Adapter CN support Transmission rate MPI PROFIBUS 9 6Kbps 19 2Kbps 45 45Kbps 93 75Kbps 187 5Kbps 500Kbps 1 5Mbps _5 TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR JU FF FOURSTAR Electronic Technology Co Ltd De Yang China 2 External structure amp pin definition LG ED Default ee 101001 Default Ethernet Pw ae TxD arb 14 fa te TI ETH Adapter CN Ver 36 Ethernet to DP AFI Network Adapter for SRC System E ther net RS 465 Isolated PAET Timer 18 DP AFI DP MPIED GHEJ PLO Ethernet interface Standard RJ45 socket automatically adapt 10M 1000M Ethernet Use the standard network cable not crossover cable whether you connect the switch router or directly connect the PC EN R S 6 TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR JU 7 FF FOURSTAR Electronic Technology Co Ltd De Yang China The network status LED indicator on the RJ45 socket LINK LED left light green ACT LED right light yellow Light on Network cable is connected Flash Sending and receiving data through Flash
8. work as Server xarunvnnnrnnnnnnunnnnnrnnnunnennrunnnnnennnunnnrvnnunnnnnnunnnnnn 27 9 Remote wireless communication in the 3G wireless internet rnrnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnnnnnnnnnnnnnn 31 1 PC work as Server ETH Adapter CN work as Client x runnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnnunnnnnnunnnnnnnnnnn 31 2 PC work as Client ETH Adapter CN work as Server anrunnrnnrnnnnnnennnunnnnnnnnnunnnnnnunnnnnnnnnunnnnnnnnnernnnnnn 32 10 Ordering MiO 45424444 33 11 Appendix basic knowledge of Ethernet x runnrunnvnnnvnnnvunnvnnnvunneunnvunnevnneunnnunnvunnvunnnunnnunnnunnnunnnunnrn 34 bh RPR 34 2 UDP NN 34 202 TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR JU FF FOURSTAR Electronic Technology Co Ltd De Yang China Preface Thanks a lot for your choosing our products Before you use please be sure to read this manual carefully you will know its powerful and perfect function and simple use This adapter is used for the data communication between Siemens S7 300 400PLC and Ethernet Internet or 3G wireless network by the MPI or PROFIBUS interface Please use according to the manual we won t assume any liability of property damage or personal injury due to your improper use We have the right to revise this maual at any time according to the needs of technology development and it won t be noticed before the revising Copyright Statement Any people and insti
9. 546 http www fourstar dy com FOURSTAR JU FF FOURSTAR Electronic Technology Co Ltd De Yang China Basle setting Network Channel 2 BO thi BEE FARM apply Settings Rest 11 BAH amas SAJES BENLASFST IR SENE Refresh 6 STEP7 software setting We have setted the serial port parameters of ETH Adapter CN as 19200bps 801 When the VCOMM virtual serial port software running on the PC simulate ETH Adapter CN as the COM port on the PC the next using is just like traditional PC Adapter you could choose to connect the MPI port or DP port of PLC depending on your requirement and choose the corresponding protocol option in the set PG PC interface of STEP7 Also the MPI or DP baud rate which you choosed in the set PG PC interface of STEP7 must be same as PLC baud rate Otherwise It can t normally communicate If you don t know the PLC MPI or DP baud rate please choose PC Adapter Auto to check 14 TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR EF FOURSTAR Electronic Technology Co Ltd De Yang China iRE PG PC 0 att PC Adapter MPI Wale LLDP AEE Ro FARE FIA PG A me STONLINE STEP 7 gt PC Adapter MPI PG PC PH PME EXA 0 STEP 7 PRERE WEHE Ca bo H APAPO Ale Bi CP ES BAD Ds gt 4 me EH 2 4 iil HAPC PPI cable PPI mer PEL cable Fel HER CL Tadh H 31 I
10. 57 300 400PLC and power on the PLC The same local area network router can connect multiple ETH Adapter CN but the same IP address is not allowed there will be conflicts if the same IP and it only shows one of IP and abnormality You can press the Default button on the ETH Adapter CN any time that could make it restore to the factory dafault IP 192 168 0 250 Username admin Password admin You need to check your computer s IP address and gateway address and confirm your computer is in the normal Internet access in the next setting you need to set the gateway of ETH Adapter CN as same as the gateway of computer and router that is to say the ETH Adapter CN and 10 TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR py ea FOURSTAR Electronic Technology Co Ltd De Yang China computer are in the same subnet all equipments in this subnet and routers have the same gateway Enter the operating system and then right click Network Neighborhood gt View Network Connection gt Properties then pop up local JENTE x Generic Marvell Uh ze EE AAT SURE 0 SIMATIC Industrial Ethernet 1503 th sean FH 1 ETT AH ix Internet Mi ie GRIM EA FJES Be Pees AVGA BMD EH HE TE connection properties window Yukon Chipset based Ethernet t Brom co wT TED E cg Select the General page click the Properties then pop up the following win
11. C simulate the ethernet interface of ETH Adapter CN as serial port COM port on the PC then choose this serial port in the local connection of STEP7 software like you use the traditional PC Adapter Notice The COM port of local connection in the set PG PC interface menu of Siemens programming software STEP7 can most support COM8 even though it can display above COM8 in fact it can t use About the detailed instructions of the VCOMM virtual serial port software please read VCOMM virtual Serial Port software Manual Here the serial port parameters setting of ETH Adapter CN is introduced The baud rate of ETH Adapter CN serial port supports 9600 115200bps but Siemens STEP7 software only supports 19200bps and 38400bps two baud rate The other serial port parameters of STEP7 is fixed as data bit 8 bits Parity Odd parity stop bit 1 bit abbreviation as 801 50 you must set the serial port parameters of ETH Adapter CN is the same as this or else it can t build communication Firstly set ETH Adapter CN serial port parameters in parameters setting software where the serial port protocol box RS232 option is supporting RS232 RS485 RS422 communication and must ensure that this serial port parameters and the STEP7 software parameters are the same that s 19200bps 801 or 38400bps 801 Otherwise It can t normally communicate We all use baud rate 19200bps in the following examples oe lee TEL 86 838 2515543 FAX 86 838 2515
12. ERF FOURSTAR Electronic Technology Co Ltd DeYang China 1 PC work as Client ETH Adapter CN work as Server TCP Client 57 300 400PLC TCP server Set the ETH Adapter CN network parameters the gateway of ETH Adapter CN PC and router must be same the DNS server needn t to be setted because you don t use the dynamic domain name on the Internet P Channels 0 Obtain automatically User config i 3 192 168 1 250 Password setting TP ihk apply Settings Resi 10 FHRA 4 255 255 255 0 aes T a pase 192 168 1 1 HB DNS AR Ss 23 EAC HH ht 218 6 200 139 EE amp HONS RSE 61 139 2 69 Tin B Refresh OK Close The setting of ETH Adapter CN serial port parameters is omitted here you can see the previous 4 ETT description Set ETH Adapter CN working mode as TCP Server port No 27011 waiting for clients to connect ve TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR py ea FOURSTAR Electronic Technology Co Ltd De Yang China Basic Setting Network Channel 2 Pass HH z TCF j i 3 Channels Worked s Server AVA ee fe oe t AutoStart amp Channel2 te A Hostlist2 dite LP 9 0 0 0 HA Fi Ox o EM 0 a DNS AARATI 1800 AR Itt ig 5 27011 Flush Input Buffer ff fPAUR A sell ite FLIP Ace Flush Output Buffer B BY Bf 8 Refresh Run the VCOMM virtual serial port software on the PC set the simul
13. FOURSTAR Siemens S7 300 400PLC Ethernet Adapter ETH Adapter CN USER MANUAL FOURSTAR BF FOURSTAR Electronic Technology Co Ltd DeYang China INDEX 2 11 EE NE E a E E NE 3 CODVFIGHt Satemenna AET reader 3 Version NN arve 3 Related B fo od gg EE EE NN EE 3 Product Gog EEE AE AE NN EAN 3 1 Characteristics amp Technical Parameters 0 ccccceeee eee eee eee e sense eens eeeee seen ene eee 4 2 External Structure amp PIN DETNNINON sis sasccsesrmcsseveticecsunsysesieaetsestancmecsdinssedatenebemesd cartenssensdmantonsensesvesesenss 6 MT DE ANN ees ences sone ese coceee E E deme cssceseeesedesweescence assessed ouemeuiee saad oresmmocssiecteus 8 4 ETH Adapter CN Installation ixscecsspcsecrccncrenceascnssaasosnacaradedecatatennsnsatanededaamwertanedasuwseneetiweradetetsmensacaece 9 5 ETH Adapter CN Parameters SeUTnqasssoesn eee 10 6 STEP SOMWale SANN saker 14 Tete IN INE LAN vvs 15 1 PC work as Client ETH Adapter CN work as Serve r xarannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 16 2 PC work as Server ETH Adapter CN work as Client r rannnnnnnnnnnnnnnnnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnen 18 8 Remote communication in the internet xarnnnnnnvnnvnnnnnnvnnvnnnnnnvnnnnnnnnnvnnnnnnnnnennnnnnvvnnnnnnnnvvnnnnnvuneunve 21 1 PC work as Server ETH Adapter CN work as Client annrnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnnnnnennnunnnnnnnnnnnnnnnnn 22 2 PC work as Client ETH Adapter CN
14. ae cg 8800 Run the VCOMM virtual serial port software on the PC set the simulated virtual serial port on the PC Select VCOMM as Server mode accept client connections Choose to use the device detector to create a virtual serial port Bie VCOM MEN 188148 IE At EVCOMLE HAD a I HE VCOMISE T HClient r paiT Eserver Anet Add a new virtual serial port the monitoring IP address PC IP address client mode device try to connect the port VCOMM software port this is 8000 25 TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR JT x FF FOURSTAR Electronic Technology Co Ltd De Yang China P P ROSH amp 0 CoX3 1 Eitt IA IPH YL 192 168 1 108 2 Client n ANSEES Wee hem 8000 3 ATIR TN Server hd Bid Click OK and exit the software and re run VCOMM the server VCOMM will wait the connection of client ETH Adapter CN then it will create a new serial port COM3 after establishing the connection and it will appear in the Device Manager of the Windows system then you choose this serial port in your application software such as STEP7 EMSOREESH GA PEO AF EG ESO AAAA SMS PAORO BE TEEN Of course you can use multiple ETH Adapter CN to simulate multiple PLC as multiple COM port on the PC set the connection with multiple different ports in order to achieve the data communication and control operation of the PC and multiple PLC respectively
15. ain name service and charges issue Firstly you need to apply adynamic domain from DNS service provider and download the Dynamic DNS client software run this software on the host of Server mode PC or router with DNS function After the client software has been successfully started Server host has solved the problem of dynamic IP address Input the dynamic domain name in the IP input box of Client remote host set the DNS server IP address as the local DNS server IP addresses then you can use the dynamic domain name to visit the internet In the following example use our free dynamic domain name fourstar vicp cc use the PC in Server side and run the dynamic domain name client software you can also use a router with the function of dynamic domain name 1 PC work as Server ETH Adapter CN work as Client S7 300 400PLC TCP Client ee TCP Server TCP Server The most economical way to achieve the remote communication in the Internet between the PC 2272 TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR EBF FOURSTAR Electronic Technology Co Ltd DeYang China and S7 300 400PLC is that set the ETH Adapter CN as the client set the PC as the server install and run the DNS software on the PC and set the Port mapping for PC on the router of PC side As shown below Set ETH Adapter CN network parameters the gateway must be the same as the router connected with the ETH Adapter CN here y
16. ang China 4 RTS AS RTSAS control signal when it has data receiving the Input ds 5 M5V RS485 signal ground and SP 5VDC power ground e Pv o Mowe oo S P24V 24VDC power positive Input LIG A RS485 signal negative Input Output RTS PG The adapter RTS output signal when the adapter is 44714 Output sending signal the signal is 1 this signal is not connected to MPI extension cable Shell Shielding Shield ground chassis ground Panel communication indicator there are three LED indicators on the panel and its working state as the following table PWR Red Power supply normal Fault or no power TxD Yellow Fault or signal Serial port is Fault or no RxD Green Fault or signal Serial port is Fault or no 3 Inner Diagram Fr ak fil DESM 3 RIS PG LIG Bt Ethernet 3 LTG B Isolated 4 ETS AS o GND DP NMFI 9 kbps to 1 5Mbps T 247 2 OV DC DC Why the 24V power RJ45 port and RS485 three parties all need to be isolated That s because the 7 pin and 2 pin output 24VDC power and RS485 interface DB9F socket 3 4 5 6 8 9pin on 8 TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR EF FOURSTAR Electronic Technology Co Ltd De Yang China the PLC PROFIBUS socket are isolated if the adapter is not isolated it will damage the PLC isolation system then damage the PLC or cause interference 4 ETH Adapter CN installation You can
17. ated virtual serial port on the PC Select VCOMM as Client mode initiatively to connect the server side equipment Choose the device detector to create the virtual serial port eV COMMER BLS LIFE JE EVCOMMLE BO EFA LEE i O VCONMIE iT Serveri Th wpa EClient Anh Ane UDP FER 2 d FET Add a virtual serial port the remote server IP address ETH Adapter CN IP address remote server monitoring port ETH Adapter CN port ia TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR py ea FOURSTAR Electronic Technology Co Ltd De Yang China TCP IP EBOSH oO COMS 1 m ER A SSIPMGE 192 168 1 250 2 EARS SOMO 27011 3 MAHET Client Bid Click OK and exit the software and re run VCOMM the client side VCOMM will take the initiative to connect the server ETH Adapter CN with IP address 192 168 1 250 port number 27011 it will create a new Serial port COM3 after establishing the connection and it will appear in the Device Manager of the Windows system then you choose this serial port in your application software such as STEP7 SUWPORRESE RA RAEO AF RE MPO mf server Mil Remo BITRE BDO gt PGRET M gt BOS REST Of course you can use ETH Adapter CN to simulate each PLC as a COM port on the PC in order to achieve the data communication and monitoring operation between PC and multiple PLC s 2 PC work as Server ETH Adapter CN work as Cli
18. ay netik EIIN Pfi o FRA RBH METARA EA eS AAEN BREE ir EF www orap net I w EAR RAE aa eeecesee EAI EE gt FERD HESSE HEERA es 1 fourstar dy gicp net 2 ourstar vicp cece Click Restart Router button or re power the router to work with the new parameters Similarly when ETH Adapter CN go on external network communication you need to set the port simulation on the router connected with the server ETH Adapter CN input the IP address of router in the IE browser of PC connected with this router and then enter the virtual server setting interface of the router EMSS SHA EOLA Aa ae G Aet ER Beem Oo CA ARCS AN o P0 k Es altan fee MES ABA es ID ARS KO IPH Hu 186 1 hl hl s hl 3 00000 ri aana nonana na 2 E E EE E E p FA RSimO DNS 63 The server port local port of server ETH Adapter CN IP address IP address of server ETH Adapter CN Select the Enable click Save button to save these configured parameters Set the parameters of server ETH Adapter CN as below 2082 TEL 86 838 25 15543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR JU F FA FOURSTAR Electronic Technology Co Ltd De Yang China E Network i SELVEr _ Channels O Obtain automatically User confie ko 3 192 168 1 250 Hostlistz IP H tHE 168 1 o FME 4 255 255 255 0 i Connections Password setting
19. ction and it will appear in the Device Manager of the Windows system then you choose this serial port in your application software such as STEP 230 TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR ror AF FOURSTAR Electronic Technology Co Ltd De Yang China ARAN ii i F 42 I 20 VCOMMiait Clienttex EUPSORRBEEH E FB O gt pi 4 Mg EDEN RA RRE FREE Of course you can use multiple ETH Adapter CN to simulate multiple PLC as multiple COM port on the PC set the connection with multiple different ports in order to achieve the data communication and control operation of the PC and multiple PLC respectively 9 Remote wireless communication in the 3G wireless internet Using the wireless Internet platform of telecommunication etc network operators all the Ethernet to Serial port modules can be very convenient to achieve wireless communication that is to say you can use the wireless router to achieve the wireless communication in the LAN you can also use the 3G router 3G network card to achieve the worldwide Internet wireless communication As long as any places where the wireless Internet is available then the wireless communication between the S7 300 400PLC and PC can be achieved which has extended a broader application range In fact when you use wireless communication the setting method is almost as same as the previous introduction only 3G router wireless network card of differe
20. dow record the IP address and Internet Hikkk 4 TCP IPw4 tt the gateway of the computer for later use men EE snes IP thtt io IP HitkciI gt EPER MT PEIA PISS CD On Ssnsaeis DNS Bix DNS IES EaP ca FAH DNS ARS eS C4 OS AAT Ha IP Hihi PC JIP HH tE PC RIS Ae 23 SS hit CB v EAT AA DNS ARS Egit tk ca Jr IP R GM o itn SE TR SE 192 1668 1 108 200 209 200 192 168 202 98 2096 2068 bl 139 lt b9 mm ao FE 0 8 0 Copy the OEM Device Manager SPCNML rar file on the CD to your hard drive and extract it to the current folder do not modify the folder name OEM Device Manager SPCNML which store the TEL 86 838 2515543 FAX 11 86 838 2515546 http www fourstar dy com FOURSTAR JU setting software Double click the following icon in the OEM Device Manager SPCNML folder to run setting software sy an L F Pj PP DeviceManagement exe Ch Click the Search button in the upper left corner and then search out all ETH Adapter CN connected to the router after a few seconds as shown below amp Device Manager SPCNML Puten i fE 0 IEM i88 0 EH ah va oe0mo DeviceName IP Address Physical Address ETH Adapter 192 168 00 0 0a 02 ee fe ME Property Value Device Name ETH Adapter MAC Address 00 0 Oa 02 ee Te IP Address 192 168 1 250 serial No Firmware Version
21. ent _18 TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR JU FF FOURSTAR Electronic Technology Co Ltd De Yang China TCP Server TCP Client S7 300 400PLC Soe thal os ia aan J kan if T Internet Set PC as server ETH Adapter CN as client let adapter take the initiative to connect the PC Set the ETH Adapter CN network parameters the gateway of ETH Adapter CN PC and router must be same the DNS server needn t to be setted because you don t use the dynamic domain name on the Internet Obtain automatically a Channel 2 ba 3 1192 168 1 250 Password setting TP HE Apply Settings Resi 10 FP 4 255 255 255 0 pm 5 192 168 1 1 AAD RS 23 mac Ht ht 218 6 200 139 00 f Oa 02 ee Tf amp Arons RS 2 6l 155 2 69 Refresh Kf Close The setting of ETH Adapter CN serial port parameters is omitted here you can see the previous description Set ETH Adapter CN as TCP Client remote host IP PC IP address host port VCOMM software port No That s to say the ETH Adapter CN will take the initiative to connect the server VCOMM 19 TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR EBF FOURSTAR Electronic Technology Co Ltd DeYang China with IP 192 168 1 108 port No 8000 Basic setting 7 Network Channel 2 F Hu 2 TCP Channels Worked As Client BEER AutoStart Channel 2 En a Test
22. list2 me FLIP 192 168 1 108 5 F Ox FN 3000 e DNS HE 1800 Mg 27011 Flush Input Buffer EAA PR FAO AA tal L S TER a A BETEL TER Flush Output Buffer BR ETIE 255 Refresh ok I Close Run the VCOMM virtual serial port software on the PC set the simulated virtual serial port on the PC Select VCOMM as Server mode wait for the client to connect Choose the device detector to create the virtual serial port BEE VCOMMEML ER HF LIES EVCOMLE HAD a I HE V ONnafTiEclientt in paiT Eserver ANE Add a new virtual serial port the monitoring IP address PC IP address client mode device try to connect the port VCOMM software port this is 8000 20 TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR TI FF FOURSTAR Electronic Technology Co Ltd De Yang China Tcr IPHStEWSOSH oO C0x3 i EE TPH z Client t Meg S HE hem 8000 3 Ach Sy Hea tt Server Fi I EET SS alee BARETT Click OK and exit the software and re run VCOMM server side VCOMM will accept the client side ETH Adapter CN connection A new serial port COM3 will appear on the PC after the connection is established And this serial port will also appear in the Windows System Device Manager then you can choose this serial port in your applications like STEP j z P J Ve L al EMEDREEFE BE MLED X7 EG ENSO AOI ETRS ED BASH PAORO SE 3 Si Ta
23. nt manufacturers may have some differences in the usage so please read the corresponding product manual When the ETH Adapter CN works as the server it is best to use the 3G router with the function of dynamic domain name to connect the ETH Adapter CN The following are programs of wireless communication in the Internet wireless network platform 1 PC work as Server ETH Adapter CN work as Client Bil TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR JU FF FOURSTAR Electronic Technology Co Ltd De Yang China 57 300 400PLC TCP Client TEP Serer 3G TE HS USB 3GER JE CDNAZO00 EVDO 36 H FATS CDNAZ000 EVDO 36 EPF 2 PC work as Client ETH Adapter CN work as Server 57 300 400PLC TCP Serer 3G TE HS USB 3G EWF BJE CDNAZO00 EVDO 36 H FATS CDMAZ000 EVDO 36 EPF BO x TEL 86 838 25 15543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR IT ar Ez FOURSTAR Electronic Technology Co Ltd De Yang China 10 Order info Product name Siemens S 300 400PLC Ethernet Adapter Product model ETH Adapter CN so TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR TL 7 NERF FOURSTAR Electronic Technology Co Ltd DeYang China 11 Appendix basic knowledge of Ethernet TCP IP transport layer provides two common agreements of TCP and UDP the two protocols provide the transmission mechanism of TCP IP network applications TCP pro
24. ou still need to properly set the IP address of DNS different cities have different DNS Server IP you can use all but usually choose the local DNS you can search these addresses from Internet also can find them from the router which you are using 2 i Channele C Obtain automatically pe ES Rea IPE 3 192 168 1 250 FMH 4 255 255 255 0 HES 5 192 168 1 1 AADS RS 2 mac Ht ht 6 218 6 200 139 00 0 Oa 02 ee T s amp Anns ARS 23 vi Ans 7 61 139 2 69 Ties 10 Full Refresh The setting of ETH Adapter CN serial port parameters is omitted here you can see the previous description Set ETH Adapter CN as TCP Client remote host IP domain name of remote PC here is fourstar vicp cc host port VCOMM software port number 203 TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR MER FOURSTAR Electronic Technology Co Ltd De Yang China Basic Setting Network Channel 2 7 PG HHX Channelz re 5 Hostlist2 pufe HLIP fourstar vicp 5 ABS Cx Serial Setting Fm 618000 DNS Ft 1800 Password Setting tim I 27011 amp Flush Input Buffer Apply Settings Resi Ge EAS PM RORY 845 DE te E fi EAST FER Flush Output Buffer eo AT E Input the IP address of the router in the IE browser address bar of the remote PC and then appear the router setting interface set the port simulation for PC as shown below If your PC does not use
25. p AF IPI PM IPC1E L AE HE SE tt PC Adapter PROFIBUS NOS MIB O ARO ste Lahey x me ee PG PC FEAT AME vA 0 HATE CA lo Bt PC Adapter MPI MPI 1 18 23 19 T EM ED EEF C 2 v mE T 3 19200 x tant T 10 s p EM A etek py DRR RLA SPLC i DPOB AB Li rs Be eva tt CH 126 M REX 3 DP FHS BEX DHSMB EN FEDA RETTER O a CN REAR The application of ETH Adapter CN is very flexible and diverse not limited to examples described below You can use the ETH Adapter CN to connect the S7 300 400PLC to the Ethernet It can also be achieved the worldwide data communication through the Internet or wireless data communication through wireless LAN 3G network card 3G router 7 The usage in the LAN LAN communication generally refers to the same gateway that is to say the communication is among multiple Ethernet devices which are connected to a same router The ETH Adapter CN communication in the LAN needs to ensure that PC ETH Adapter CN and routers have the same gateway The gateway 192 168 1 1 the computer IP address 192 168 1 108 ETH Adapter CN IP address 192 168 1 250 in the following examples Of course you also could not use router and use RJ45 cable to connect the ETH Adapter CN and computer directly 15 TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR IT H
26. put the ETH Adapter CN on your desk or install it on the rail of control cabinet It has the mounting bracket accessory User can self make an Aluminum board with thickness 1 5mm 2 5mm then install the adapter on the S7 300 400PLC rail or 35MM standard rail 120 aluminum boss thickness 1 5mm7 2 5mm Fix the Aluminum board on the S7 300 PLC rail sige TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR JU FF FOURSTAR Electronic Technology Co Ltd De Yang China SIEMENS ETH Adapter CN adapter has been installed on the S7 300PLC rail 5 ETH Adapter CN parameters setting ETH Adapter CN needs to be configured the parameters to work correctly the configuration parameters including the network parameters communication protocols connection serial port parameters it can be very flexible to satisfy your application Configuration parameters are stored in the Flash memory and they can be permanently stored without loss Use the standard RJ45 cable to connect the ETH Adapter CN and router or switch at the same time make sure that the router or switch is connected to a computer in order to run the parameters setting software You also can use a standard RJ45 cable to directly connect ETH Adapter CN and the computer no need crossover cable this product has auto polarity discrimination function for the RJ45 cable Insert the DP MPI plug DB9M of ETH Adapter CN into the DP or MPI socket of the
27. server will go on the duplex data communications 2 UDP mode UDP protocol is unreliable connectionless protocol data transmission is not required to establish a connection do not need to receive confirmation form the host for data transmission so the UDP protocol does not guarantee the data sent to the target host packets are received correctly for high reliability requirements of the occasion can use the higher level of communication protocol to ensure data is correct UDP is a relatively simple way of communication it will not increase too much extra traffic it can communicate faster than the TCP to provide real time communication UDP does not need the server and client both parties are on equal communication Our Ethernet to serial communication module using UDP mode including UDP Uni Cast UDP 34 TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR JU B FOURSTAR Electronic Technology Co Ltd DeYang China Multi Cast UDP unicast UDP Uni_Cast mode Module in the UDP Uni Cast mode it can be point to point duplex data transmission although it can send data to several other hosts but only one host can send data to the module back UDP Multicast UDP Multicast mode The modules in the network use the multicast ID is one between 224 0 0 0 239 255 255 255 address as its multicast group address all the modules in the multicast network can be duplex data transfer and no master slave di
28. stinguish This mode is easy for old RS485 network upgrade to Ethernet se TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com
29. t easily damaged problem High speed reliable industry standard anti interference design suit for the harsh electromagnetic environment 32 bit RISC NP7 series ARM7TDMI 55DMIPS 128KB SRAM 128KB Code 32KB Boot 10M 100M adaptive Ethernet interface Support MPI and PROFIBUS communication protocol The largest baud rate is 1 5Mbps for MPI and Profibus interface Ethernet interface baud rate 9 6Kbps 19 2Kbps 38 4Kbps 57 6Kbps 115 2Kbps can be set Smart Protocols TCP UDP ARP IP ICMP DHCP BOOTP DNS Support Dynamic DNS Working mode can be chose TCP Server TCP Client UDP Multicast and UDP Unicast Built in Flash memory can save the setted parameters Support Windows 95 98 ME NT 2000 XP 2003 XP Vista Win7 operation system RJ45 port 1500VDC electromagnetic isolated RS485 interface 1000VDC electromagnetic isolated power supply 1000VDC electromagnetic isolated Interface protection power supply port has the reverse polarity protection and over current protection RS485 interface has the anti lightning surge protection repeatability surge capacity Ipp 100A 10 700us 4KV meet standard ITU TK20 21 VDE 0433 15KV ESD protection overcurrent protection Power supply 24V 10 DC from PLC MPI or PROFIBUS socket ZW power Shape Size 123mmx68mmx30mmi length width height with the mounting bracket Temperature 40 C to 80 C 40 F to 176 F 5 to 95 RH Storage temperature 40 C to 80 C 40 F
30. tutions copy all or part will assume the corresponding legal responsibility without prior written consent Version Info Document Name ETH Adapter CN user manual Version V2 0 Revising Date Sep 25 2010 Related Documents In order to use this adapter better please also read the following two documents 1 Device Manager Parameter Setting Software Manual 2 VCOMM Virtual Serial Port Software Manual Product Content 1 ETH Adapter CN 1PC 2 RJ45 Cable 1 PC 2M 3 CD 1PC s TEL 86 838 2515543 FAX 86 838 2515546 http www fourstar dy com FOURSTAR JU BF FOURSTAR Electronic Technology Co Ltd DeYang China 1 Characteristics amp Technical Parameters ETH Adapter CN is the industrial product which use the Ethernet and Internet or 3G wirelss network to achieve Siemens S7 300 400PLC networking communication It integrates many complex network protocols support TCP Server TCP Client UDP Unicast UDP Multicast etc many modes It has 10M 100M adaptive Ethernet interface and MPI and PROFIBUS interface which meets Siemens technical specifications You only need to go on simple setting and then let the 57 300 400PLC go on network communication The RJ45 port RS485 interface and power supply port are all isolated in order to suit harsh environment in the industrial situations Especially the isolated power supply port and each signal pin has anti static protection and surge protection which can solve the PLC communication por
31. vides a guaranteed and reliable information transmission and UDP use non guaranteed and non reliable method to transmit information 1 TCP mode TCP is a guaranteed connection based protocol before transmitting the equipment must first establish duplex connection disconnect after data transfer is complete Sending the data need to receive confirmation of the host then continue sending data if not received confirmation of the host or data error need a certain number of retransmissions In this way it will be additional traffic so slowly than UDP TCP communications including the client Client and server Server the client take the initiative to connect to the server the server can only be a passive client connections once establish the connection the client and server can be duplex data transfer at any time Our Ethernet to serial communication module using TCP mode including TCP Server TCP Client TCP Server TCP Server mode When the module works in the TCP Server mode it does not take the initiative to connect to other devices but listening on local port and wait for client connections if the client can establish a connection then will go on the duplex communications TCP Client TCP Client mode When the module works in the TCP Client mode it will take the initiative to connect the setted TCP server in advance if the connection is not successful it will continue to attempt to reconnect once the connection success the