Installation & User Manual V2.062
Contents
1. Network Diagrams for Multiple Controllers On the Controller Tab set the Connection Type to Serial 12V On the Settings tab in the communications section Select the Serial Port RS485 Converter number from the drop down list connected to the Controller a Controller 1 a 2 vag Setting the Controller address a ov 25 Connect using RS232 RS485 S Ar R The Controller Address is set by configuring the Dip switches as shown below cable to serial port on PC Daisy Chai Set Baud Rate to 19200 eae Pear PC Network Connections when using more than one Controller Daisy chain the PC network A B OV to each controller Set an individual address for each controller between 1 amp 3 using the dip switches see below Controller 2 Direct Connect All OFF Address 1 Set SW1 ON Address 2 Set SW2 ON Note Address 3 Set SW 3 ON only Controller 1 Controller 2 Restoring Factory Settings To restore the factory default setting Set ALL Dip Switches 1 2 3 amp 4 to the ON position and then power up the Controller Example All Dip Switches are set to the ON position EE el k Ee es ae 3 Note Factory Default settings will be restored after powering up the controller with All dip switches ON The dip switches s should then be set to the controller address as shown above in section Setting the controller address Address 1 Set SW1 ON Address 2 Set SW
2. Create a new W i Enterprise Site and give it a name of the new installation site C Log in to the application as the Engineer not the administrator with the password 6666 D Connect to the Controller Refer to page 12 amp 13 for setting up DHCP or Static IP addresses E The Controller icon will change colour to show that the Controller is on ine F Go to the Current Events tab and verify the log messages indicate the controller is on line Note It will take about 20 60 seconds to complete a pop up will appear when the netwrok has been created Operation Instructions gt Phase 3 Enrolling Door Controls steppes O E All Door Controls should be installed at this point and powered up All Door Controls must be defaulted before joining a network Note Door Controls will be shipped with their factory default settings Enter Engineer mode on each Keypad Door Control in the following way Press X followed by 6666 Enter 55 to default Press the tick to confirm the keypad will now go through the process of defaulting itself The process could take 20 30 seconds The LED will flash once every second when it is complete Repeat the process for all keyoad Door Controls Enter Engineer mode on each Wi Bio Door Control in the following way Enter 6666 Enter 55 to default Scan Finger to confirm the Door Control will now go through the process of defaulting itself The process could take 20 30 seconds The
3. LED will flash once every second when it is complete Repeat the process for all W i Bio Door Controls Enter Engineer mode on each Prox Only Door Control in the following way A Adda programming card to the Door Control by presenting a card twice on power up The security wing must be removed first Present this new programming card to enter Engineer mode Present the programming card again to select Default mode Present any other card once to default the Door Control The process could take 20 30 seconds The LED will flash once every second when it is complete Operation Instructions ij Phase 3 Enrolling Door Controls EZ Description The controller is now ready to allow Door Controls to enroll onto the Network Go to the Controllers tab and Click on the W ireless Network and thenclick the Allow Doors to J oin start the controller scanning for new doors that do not already have an address only DoorControls without an address can be enrolled Note For W ired 485 Door Controls right click on the Controller on the right hand side of the application and select M anually Assign Address from the drop down menu Once all new Door Controls are found by the Controller they will all beep with the number of the next available address door position on the Controller e g if door 2 is the next available address then all Door Controls will beep at the same time with 2 beeps This is basically saying
4. and wire each Door Control Refer to the Door Control E Manual for instructions a Connect the Controller to the PC using Network Diagrams Restoring Factory Defaults EE Setting up TCP IP 6 pts Installation Diagrams JE Control Panel opening Control Panel features cable entr l access to rear y mount with 4 x 1 5 inch mount hole void for wiring No 8 Security Type screws remove screw cap remove retaining screw rear tamper Switch to remove cover pull forward on right and slide left mount hole mount hole Note If using a single Controller an RS232 cable may be used M ax cable length 10 meters Place a120ohm Termination Resistor across A amp B onthe Controller RS485 Network to Controllers M ax number of Controllers 3 M ax Cable Length 1 4 km BS x Controller 2 3 Controller 1 RS485 Network to Door Controls Max Cable Length 1 4 km Daisy Chain Configuration Only Door Control Door Control Place a 1200hm Termination Resistor across A amp B on the last Door Control in the chain Door Control Door Control 3 4 10 System Overview ij Wireless Connection to Door Controls Note If using a single Controller RS485 Network to Controllers an RS232 cable may be used Max number of Controllers 3 Max cable length 10 meters Max Cable Length 1 4 km o y Controller 2 3 Controller 1 Door Control 4 Door Control ae 1 Door ae a Door Contr
5. 2 ON Address 3 Set SW3 ON Operation Instructions Setting up TCP4P Static IP Step Descrptin OOOO Setting up TCP4P DHCP Step Descrntion OO l Default the Controller See Restore Factory settings on page 11 The default TCP IP mode will then be set to DHOP Set the Controller address to address 1 See page 11 for details Connecting the Controller to your DHCP LAN Connect the Controller to your LAN using an ethernet cable The Controller will be assigned an IP address automatically by your DHCP server Open the PC application On the Controller tab Select TCP IP with the DHCP option and enter the MAC address of the Controller and click Apply The MAC address of the controller can be found on the box or printed on the Controller PCB The Controller icon will turn blue when it comes online 00 50 C2 BD 40 XX TCP IP Settings Static IP DHCP icena ICRA Configuration Default the Controller See Restore Factory settings on page 11 The Controllers default IP address is 169 254 1 1 Set the Controller address to address 1 See page 11 for details Connect the Controller directly to a PC to using an ethernet cable Connecting the Controller directly to a PC using default IP address Connect an Ethernet cable between the Controller and the PC The default IP address of the Controller is 169 254 1 1 Set the IP address on the PC to a similar IP address e g 169 254 1 2 Note If there is no LED act
6. Other Access Control Products standalone products Also available is a range of fully functional standalone door controls for less complex door management This attractive design with modern aesthetics will complement and building 1 and 2 Door Digital Keypads Proximity Switch Biometric Switch Features 35 1000 users Access control Door monitoring Manager user fire and intruder alarm interface Backlighting Tamper resistant 5 amp relays Indoor or outdoor use Robust polycarbonate housing with stainless steel keys Mounts onto a standard electrical back box ARGUS ACCESS Wi Enterprise Controller Simple Secure Access Installation amp User M anual vos WwWwW argusaccess com echnical Specification Technical Specs Wi Enterprise Controller Technical Specs W i Enterprise Door Controls Operating Temperature 20 C to 60 C Moisture Resistance Dimensions Flush Mount Surface Mount Features Doors controlled 20 Users 20000 User Groups 128 Time Zones 128 Door Groups 128 Reporting Facility Yes Challenge Facility Yes Logging Unlimited Input Output M apping CCTV amp Lift control Supports Wireless amp RS485 Networks Automatic Backup Facility Database Encryption Installation Steps Installation Steps Step Description Page Install the Controller using the Installation Diagrams W ire the Controller using the W iring Diagrams a Install
7. f this network One door will already be added by default Default the controller immediately via the dip switch settings Click on the button to add new doors to remove doors See instructions on page 11 M ake sure all doors are Enabled and then click Save Important Once powered up and the controller has completed the default the process reset the dip switches to the correct address positions See instructions on page 11 Open the Settings Tab and do a Configuration Download to the Controlle this gives the Controller a clean set of instructions before beginning to enroll doors onto the network This will take approximately 1 minute Follow instructions on the CD provided to install the PC application ARNING A New Network should only be created on first installation Creating a new network will overwrite any existing network information and any enrolled Door Controls will be un enrolled All Door Controls will have to be defaulted and re enrolled on the new network that has just been created A new network is now ready to be created Go to the Controllers tab and Click on the Wireless Network and then the Create a New Network button Click Yes on the pop up to proceed Note M ake sure the USB enrollment reader is not connected to the PC before the PC application Is installed Launch the application A Launch the application by clicking the PC app icon on the desktop B Click
8. id 4 time periods can be created for each timezone Select Holiday Access to grant access for holiday periods Double click on the Holiday Access to add days to the holiday periods Use the calendar to select these days DoorGroups are created by grouping doors together e g all the entry and exit doors could be grouped together as Peremiter Doors Select a Door from the All available Doors window and drag it to the Doors in Current Door Group to add it to the Door Group Repeat for adding each door Phase 6 Downloading Configuration stepes O After all users access levels and door control settings have been finalised a full download to the controller should be carried out Go to the Settings tab and click on Download Configuration A pop up window will appear tracking the status of the download All settings will be downloaded to the Controller and Door Controls Operation Instructions 74 Enrolling User FingerPrints Description E Note M ake sure the USB Fingerprint reader is attached to the PC On the Users Tab Select a User for fingerprint enrollment Click on the Fingerprints button 2 3 Click on button to begin and place finger on the enrolment reader An image of the fingerprint will appear on the screen Ensure that the image quality is good and a value of at least 90 is achieved Refer to section Finger Placement for correct finger placement and exam
9. ivity on your PC s ethernet interface then the PC requires a cross over cable between the PC and the Controller Open the PC application On the Controller tab Select TCP IP with Static option and enter the default Controller IP address of 169 254 1 1 and click apply The Controller icon will turn blue when it comes online A new IP address can then be sent to the Controller using the Controller TCP IP Configuration button Sending a new IP address to the Controller e g 192 168 1 26 M ake sure the controller is online and click on the E contolie teh cangui Controller TCP IP Configuration button Choose Static IP mode and enter the IP address A Netmask and Default Gateway assigned by your IP Address network administrator Click Send new settings Netmask to Controller The Controller will now go offline as J 2 9229 the new IP Address settings are applied Connect the PC and Controller to your LAN and enter the new IP address to allow the application to communicate with the Controller Note Reset the IP address on your PC to its original setting for your LAN yontroler LCP Ar Configuration Operation Instructions Operation Instructions iE Phase 1 Setting up the Controller Phase 2 Configuring the Controller Step Descriptin O Step Description o a Install the main Controller and power up Open the Doors tab in the main menu to add the required number of new doors to be part o
10. ly 1 second Placement Wi BIO 25 Incorrect Finger Placement Incorrect Note Incorrect placement finger does not fully cover the sensor window The door control will not respond and the red light will not turn off if the sensor window is not fully covered by the finger
11. ol 2 Note Door Controls can be installed within 30 meters of the Controller or within 30 meters of any other Door Control as each Door Control will function as a repeater Each Door Control transmits data to from the Controller These distances are a guideline The actual communication range depends on building shape and Door Control construction methods used 5 10 Wiring Diagrams Wiring Diagrams W arning Installation should only be carried out by a suitably qualified person only Cable Tie Cable Tie Neutral retaining clips Earth Live Note Used ONLY for i PC Network Connections l Wired 485 Network can be used for multiple Connections controllers See page 10 for wiring Main Input Cable 230VAC s nd no s ndu Remove Battery Tab s nd no s nduj Network Diagrams Network Diagrams for Single Controller DB9 Female Serial Cable OMEN Od YYYY Connect DB9 cable to serial port on PC 4oOw v S Pe Nis Maximum cable length 10 meters NNN ew PY YIOMION 100g PC Direct Connection can be used when using ONLY one Controller Set the Direct address to ALL dip switches OFF see below Direct Connect All Dip Switches OFF See page 11 on Configuring Controller Communication to setup the application for serial Communications T Network Diagrams Network Diagrams EE Configuring Controller Communications Step Description 1
12. ple of good quality image Repeat this process if this is not achieved on first attempt Click Save using a good quality template only Poor Quality templates can lead to false rejections later when trying to gain access F Placement W i BIO Placement W i BIO FED Correct Finger Placement _ Incorrect Finger Placement Note Incorrect placement finger does not fully cover the sensor window Note Ensure that the core of finger is x P oor Qua lity Im q ge centered on the sensor window during the enrollment process This will increase the quality of the fingerprint template Ensure a value of at least 90 is achieved Note Poor Quality image No Fingerprint core on sensor window Note aoan Quality image Fingerprint core naa AE NINN This can result in poor template quality that is center of sensor window KSA can lead to false rejection issues later when Note The System does not store the finger the user is trying to gain access print It uses an algorithm to generate a binary representation using sample points from the fingerprint It uses this information to then validate each users fingerprint Correct Note Ensure that the finger is centered and placed flat to the surface and fully covers the sensor window Note Finger must remain on the sensor window until the door control acknowledges that the finger has been scanned by sounding a beep and turning off the red light This will take approximate
13. rd or PIN or PIN only lf all of these are set to inactive then access will be denied for all cards and PINs on that Door Control Example To Enable PIN codes only on a Wi PINGProx Set the Timed Action Card or PIN to Inactive and set the Timed Action PIN Only to All day Every Day This will grant access for PIN codes and deny access for cards and fobs Enable a User by ticking the Enabled box for each User Assign a Name to the User Assign a UserGroup from the drop down menu The Usergroup will determine the access levels for this User Refer to section on page 20 Configuring Access Levels for information on User Groups Assign a Card PIN number and enroll FingerPrints for the User Refer to section FingerPrint Enrolment on page 22 Click Save to transmit these changes to the Controller Operation Instructions Phase 5 Configuring Access Levels Step Description SSS O Oo Access Levels are controlled by creating UserGroups and assigning the UserGroup to a User as described in section Configuring Users UserGroups are created by combining pairs of DoorGroups with Timezones Each UserGroup can have up to 6 pairs of DoorGroups and Timezones Select DoorGroups and Timezones from the drop down menus to add to the current UserGroup Timezones are the periods of time for each day of the week that access will be granted Select times and tick the days of the week this time is val
14. that any door can be assigned to this address It s up to the installer to decide which one Also you will notice that the Key back light of the keypad Door Controls will be illuminated with the next available address as well le Key 2 will be illuminated for this example Go to the Door control that you want to make door 2 on the network system it should be beeping 2 times Press any key on this keypad and the system will automatically assign this door control to door 2 address on the system Present a card if the Door Control is Prox Only Note All other Door Controls will now start beeping with the next available address i e 3 beeps address 3 in this instance and so on every time you enroll a new Door Control The Key back light will also correspond to each address as the system fills up Operation Instructions Phase 4 Configuring Users Phase 3 Enrolling Door Controls Step Description S L Once all Door Controls are enrolled onto the network go back to the Controller application and click the Secure Network button this safeguards the systems if you select another tab on the application this will happen automatically Select each Door on the application and configure individual settings such as Door Name Timed Actions Relay Times Ajar Times Door Option and Alarm Options etc IM PORTANT A timezone must be selected in Timed Actions for one of the options Card and PIN Any Card Ca