Home

Insight Lite - Strumedical.com

image

Contents

1. Operation Manual Insight Lite FETAL MONITOR Ver 1 0 medical ECONEL OPERATION MANUAL Insight Lite FETAL MONITOR Ver 1 0 Table of Contents Introduction 3 Warranty Period mee 4 Service Request eee 5 How to contact us 6 Chapter 1 How to use the User S Manual Yide S Es e I eee ee 7 ii Gone asisten se bb O i a 7 lO oS EEUU URN 7 1 3 Meaning of Symbols in the User s Manual 000eeeeeee 8 Chapter 2 Precautions for Us w ANE 9 2 1 Precautions for Using Environment 9 2 2 Precautions for Electric Safety 11 23 Maintenance and Cleanness pov DM ATITEA TE AN 12 Chapter 3 Overview of Insight Lite 7 13 3 1 Principle and Features of Insight Lite 13 32 Composition memes 13 3 3 Parts 14 ZA Symbol ed e RERO RAN RUE UI eae 17 4 1 Precautions for Installation e 4 2 Installation of Main Body eee 4 3 Cable Connection ee 44 Pinter Paper Loading UM IAN UO RI MR Chapter 5 How to use Insight Lite o 22 5 1 Before using Insight Lite 55er ope ubt 22 5 2 Using Insight Lite 22 5 3 Basic Screen eee 23 54 Functions of Keys ni ii ii ia i deae die Ng 24 5 5 Measurement of FHR and UC 25 5 6 How to use Event Mark 29 5 7 How to use the printer rasti vs a 30 5 8 Volume Control 32 5 10 Soutid eost mte OU M RR 35 5 11 AST Optional sectas iii qaia cid 35 Chapter 6 Setting by Menu Function 6 I Record Seting beret dtes edite 6 2 Alarm Setting a
2. 4 3 Cable Connection 1 Power Connection DC POWER INPUT POWER CABLE CONNECTOR 0000 0000 pr Stick the Power Cable into Insight Lite Power Connection Terminal and change the Power Switch of the left face into O status Then the device is powered on If you cannot use the power cable you can use DC adaptor which suggest DC15V and 3Amp We recommend the power cable than the adaptor The adaptor which is DC 15V and 3Amp is optional accessory 2 Connection of Main Body with Probe Connect the probe desired to be measured to the connection terminal part on the left face of the main body If not properly connected problem may occur CONNECT CONNECT PROBE MARK JACK How to install Insight Lite 19 FETAL MONITOR Ver 1 0 3 Ground Cable Connection Connect the Ground Terminal of the main body with the Ground Terminal of the installation place CONNECT EARTH Y CABLE 4 Serial Cable Connection Connect the Serial Connection Part of the main body with the Serial Terminal of the installation place V A Serial Com 20 How to install Insight Lite Insight Lite 44 Printer Paper Loading In order to put the printing paper in the tray push the buttons on the side of the front panel of the printer door and pull forward 1ECONET L J 20bpm SPEED cm min 293 m Insight KC M
3. equipment installation usage and maintenance 8 How to use the User s Manual Insight Lite CHAPTER 2 Precautions for Use 2 1 Precautions of Using Environment Avoid using or storing the device under the environments as follow Keep it away from wet place or Keep it away from direct do not use it by wet hands sunlight Avoid areas that have high fluctuations in temperature Temperature Range for Keep it away from any electric Use 10 C 45 C Humidity 30 85 heater Avoid areas of high humidity or Avoid areas susceptible to ventilation problems large shock or vibration Precautions for Use 9 FETAL MONITOR Ver 1 0 Avoid areas near chemicals or explosive gas L Do not disassemble it We WILL NOT be responsible under any circumstances in this case Hold the plug to withdraw the power cord Basic environments for use are as follow Temp 10 C 45C e Pressure 70 106 KPa Humidity 30 85 Basic environments for storage are as follow e Temp 10 C 50 C e Pressure 70 106KPa e Humidity 20 95 10 Precautions for Use Make sure to not let any dirt or especially metallic objects from going inside the equipment Do not power it on before completely installed Otherwise it may be damaged IPX7 DOP UC Probes Do not submerge the probe for 5 hours or longer Insight Lite 2 2 Precautions for Electric Safety Before using the device please check the items
4. Li ion Battery Serial Cable 2ea lea lea lea lea lea 1 set 3ea 1ea Insight Lite Specification 59 FETAL MONITOR Ver 1 0 0470 Product Name Fetal Monitor Model Name Insight Lite Item Certificate No Item Certified Date Manufacturing No Warranty Period 2 years Purchasing Date DD MM YY Customer Hospital Name Address Name Tel Seller Manufacturer x Thank you for buying Insight Lite x This product is a medical device x This product is under thorough quality management and complied with strict test x This product can be repaired replaced or refunded in accordance with Consumer s Damage Compensation Regulation noticed by Economic Planning Board
5. the calculated heartbeat shows on the screen If heartbeat is under 50 or heartbeat sound cannot be measured heartbeat area shows If the heartbeat displayed on screen goes over or under the alarm level limit an alarm will sound and alarm lamp will change green to red and FHR value will be twinkled Also if the probe line is cut or the probe has been pulled off from the machine and if it is disabled during usage each of the FHR on the FND will show PRO OFF and d 1 d 2 UC will displays by turns in the maximum minimum alarm level FND The error code will also displays in the Auto Print FND And information sound ding dong ding dong will be heard 26 How to use Insight Lite Insight Lite Error Codes Paper Out during printing DOP Probe is disconnected during using DOP2 Probe is disconnected during using If E2 error occurs it will not be displayed UC Probe is disconnected during using If E2 or E3 errors occur it will not be displayed Low Battery If E2 E3 or E4 errors occur it will not be displayed How to use Insight Lite 27 FETAL MONITOR Ver 1 0 m FHR Measurement 1 Touch the patient s belly and search for the fetus s back and place the DOP Probe If the fetus is positioned facing left or right place the probe as shown on the picture ZA NS Doppler Probe If the probe is placed on the front of t
6. 5 Mark Jack Connection Part 6 UC Probe Connection Part 7 ID Label Overview of Insight Lite 15 FETAL MONITOR Ver 1 0 Rear Face 1 Handle for Carriage 2 Adapter Power Connection Part 3 Ground Terminal 4 AC Power Connection Part 5 RS 232C Cable Connection Part Do not disassemble the device Otherwise you may be electrically shocked The device shall not be disassembled by other than the person qualified for our product service 16 Overview of Insight Lite Insight Lite 3 4 Symbols Symbol Description Symbol Description SK isv 3anc Power Input JE Print Start End DC 15V 3A Type BF Device e Electric Shock Device 7 pone Protection pay Warning or Precaution i N See the User s Manual Volume Control l O AC Main Power On Off ph Back to Default Screen Exit DOP1 DOPI Probe Connection Part A Setting Change DOP2 DOP2 Probe Connection Part v Setting Change setup Save the Setting UC UC Probe Connection Part TONES Back to Mem mode MARK Mark Jack Connection Part DC Communication Port SILENCE Ethernet Connection Terminal feu AC Power Input Part Terminal for Equipotent by Connection of Each Part of P Working by AC Input Y Device System without Necessity of Ground Potential LLULL Working by Battery Overview of Insight Lite 17 FETAL MONITOR Ver 1 0 CHAPTER 4 How to install Insight Lite 4 1 Precautions for Installation Precaut
7. DOP2 with process 2 6 8 Press the Exit key J and move to the basic screen after all setting Using the Volume Key 1 Press the Volume key to move to menu setting mode The initial setting is to control DOP 1 If you press the Volume key once more DOP 2 will be controlled DOP 1 and DOP 2 are will be changed by the Volume key 2 Adjust the volume to use Up Down key A V after choosing DOP 1 or DOP 2 DOP 1 or DOP 2 can be adjusted to repeat process 1 and 2 3 Press the Enter key 4 or Exit key J at the desired level and the volume control operation is complete If you press the Enter key the desired level will be saved If you press the Exit key the volume level will be returned to previous level The Volume of Key Sound Alarm Sound and Information Sound cannot be adjusted If the alarm sound happens you can turn off the sound to use SILENCE key If the information sound happens you can turn off the sound to use Exit key How to use Insight Lite 33 FETAL MONITOR Ver 1 0 5 9 Alarm On Off 1 By default the Alarm function is On when you turn the Power on 2 When the values go over or below the Alarm range the beep will sound The user can stop the alarm Press the SILENCE on the front of the device and the beep does not sound for 3 minutes If you press the SILENCE two times the beep does not sound until press the SILENCE AL OFF will be displayed du
8. be twinkled Then press the Up Down key A V for changing the level Step 6 After setting is completed if press the Exit key 4 menu will move to previous mode Step 2 without saving If press the Enter key 222 menu will move to previous mode Step 4 with saving Step 7 After all setting is completed press the Exit key 2 to move to the basic screen 44 Setting by Menu Function Insight Lite 6 4 Time Setting Date and Time Possible to set the time Description Setting Range Sets year 2000 2099 year Display last 3 digits Sets month 1 12 month DAY Sets day 1 31day HOUR Sets hour 0 23 hour MINUTE Sets minute 0 59 minute Setting by Menu Function 45 FETAL MONITOR Ver 1 0 Step 1 Press the Setup key lt to move to menu setting mode in the basic screen If you press the Exit key 4 menu will return to the basic screen Step 2 Press the Up Down key A V to move to the Time menu in the menu setting mode Step 3 Press the Enter key 4 to move to the detailed setting mode Step 4 Press the Up Down key A V to move to desired setting mode among Auto Print Offset Zoom Speed Contrast and Fetal Movement If press the Exit key 3 menu will move to the SET UP previous mode Step 2 If press the Enter key 4 y77 menu will move to the detailed setting mode of each mode 46 Setting by Menu Function Insight Lite Ste
9. data to inform the level of her labor pain and frequency Insight Lite is that the adjustments and values of the signals can easily be controlled with simple key controls Insight Lite is capable of measuring twin fetus and supports an optional central monitoring system on serial communication It is also available AST optional function 3 2 Composition Basic Accessories Supersonic Probe DOP 1EA UC Probe 1EA Event Mark Jack 1EA Printer Paper 1EA Power Cord 1EA 110V AC Conversion Jack 1EA User s Manual 1 Volume Supersonic Gel 1EA Belt for Probe Fixation 3EA Options Central Monitoring Device Cable Communication Program Cart AST Probe Internal Battery Overview of Insight Lite 13 FETAL MONITOR Ver 1 0 3 3 Parts Front Face amp Control Panel SILENCE L J medicalEC NEC SPEED cm min 62 3 Insight U J TTT TI 1 Display for FHR 1 Value 2 Display for FHR 2 Value 3 Display for Alarm setting 4 A C amp Battery Power LED 5 Warning On Off Key 6 Display for UC Value 7 Display for Printer setting 8 Key Control Panel 9 4 Printer 10 Alarm LED Lamp 14 Overview of Insight Lite Insight Lite u Left Face 1 Handle for Carriage 2 DOPI Probe Connection Part 3 DOP2 AST Probe Connection Part 4 AC Power Switch
10. 6 3 Volume Setting shen ainetn an in ii i aa GA Time Setting Linui detienen 6 5 Default Setting PE LUN CIARA E T da Ni A Sate S E NAA 48 Chapter 7 Solution for Precaution and Warning lt 49 Chapter 8 Power Ree mne teet ce 54 8 1 AC Power 54 82B attery Power Optional Tai ais sd laso Ee AEE a asa a ias DAS 54 Chapter 9 Simple Troubleshooting 56 Chapter 10 Specification shea dete 57 Insight Lite INTRODUCTION GENERAL Thank you for buying Insight Lite Fetal Monitor For safe use stable performance and follow up management please read this manual before using the device Before using the device please read this manual to perfectly understand the basic function using method and maintenance method of the device so that you can assure the safe use and long term stable performance of the device We MEDICAL ECONET provide you with reliable products only The device shall be assembled extended amended repaired by us or the person certified by us The device shall be installed meeting relevant regulations including electrical installation and etc The device shall be used in accordance with the User s Manual The device shall be used under the direction of the person who is medically certified This device is used to monitor the fetus s status For the patient s safety use only the parts and accessories recommended by us If you connect the device with any part or accessory not specified in the Us
11. EEUUUUAuuurteeLLnLALLAA O LUUUCLUCIZ When you pull the door forward the door will open and you will see the area where you can place the roll of printing paper as well as the printer machine and black roller on the inside of the door Make sure the paper s printing side is facing up and then close the printer door Printer paper should be printed side upward If not it will not be printed on the paper How to install Insight Lite 21 FETAL MONITOR Ver 1 0 CHAPTER 5 How to use Insight Lite 5 1 Before using Insight Lite Check for following items before measuring the condition of the fetus Possibilities of any mechanical danger Power plug and cable and accessories All items and equipment necessary to measure and inspect the condition of the fetus 5 2 Using Insight Lite Connect the probe you want to use on the main body Normal procedure is as follows Pre labor diagnosis for non twin fetus DOP I Probe UC Probe Mark Jack Pre labor diagnosis for twin fetus DOP I Probe DOP II Probe UC Probe Mark Jack Wake up the baby AST probe optional Step 1 Turn on the Power Switch Step 2 Attach the probe to the patient Refer to 5 5 5 6 and 5 7 Step 3 Sound signal is heard Step 4 Measured signal is displayed on the FND as numbers Step 5 Record the measured readings with the print function Step 6 SETUP Key is used to modif
12. Lite 6 2 Alarm Setting Possible to set the Alarm Sounding Area Symbol Description Setting Range High If HR value is measured not smaller than 50 240 bpm the top limit ALARM will be made Initial setting 160 bpm Tf HR value is measured not bigger than 50 240 bpm the bottom limit ALARM will be made Initial setting 80 bpm Low Step 1 Press the Setup key 25 to move to menu setting mode in the basic screen If you press the Exit key J menu will return to the basic screen Step 2 Press the Up Down key A V to move to the Alarm menu in the menu setting mode Step 3 Press the Enter key 4 fer to move to the detailed setting mode Step 5 Press the Enter key Gh in Step 4 and desired the level will be twinkled Then press the Step 4 Press the Up Down key A V to move to desired setting mode among Auto Print Offset Zoom Speed Contrast and Fetal M t If the Exit k ill Up Down key A V for changing the level Refer to the above setting range in the table set Zoom Speed Contrast and Fetal Movement If press the Exit key 2 menu w move to the previous mode Step 2 If press the Enter key lt 227 menu will move to the detailed setting mode of each mode This system is not changed during printing 40 Setting by Menu Function Setting by Menu Function 41 FETAL MONITOR Ver 1 0 Step 5 Press the Enter key 277 in Step 4 and desired the l
13. P oUt and Pro oFF with error code by turns 50 Solution for precaution and warning Insight Lite Probe is disconnected with silence for 3 minutes Display AL oFF and 3 MI with error code by turns Probe is disconnected with paper out and silence for 3 minutes Display AL oFF and 3 OW MI with error code by turns W Solution for precaution and warning 51 FETAL MONITOR Ver 1 0 Insight Lite Probe is disconnected with paper out and silence Display AL oFF with error code by turns Paper out with silence Display AL oFF with error code AUTO PRINT Low Battery Display bAt Lo with error code if internal batter is instlled optional AUTO PRINT If no management with low battery within 10 minutes the device will be turned off Before turning off the device connect AC power and charge the battery If the device is turned off with low battery message the device will not be turned on before connecting the AC power 52 Solution for precaution and warning Solution for precaution and warning 53 FETAL MONITOR Ver 1 0 Insight Lite CHAPTER 8 Power If the device is not operating with battery please do not open the device It does not replace BPM 900L is powered on by both AC DC It is powered on by AC basically It is also powered the battery from the external Do not dispose the battery in any dangerous place for on by DC Battery Optional while being
14. as follow Is the power supply line of the device proper 100 240V Ac s every connection part power line or any optional device connected to the device properly For correct connection method see the Chapter 4 s the device completely grounded Otherwise noise may be made To avoid electrical noise or disturbance install the device away from generators X ray devices broadcasting devices and idle wires Inaccurate reading may show in case above mentioned devices are nearby The Insight Lite requires a separate power source and stable connection Inaccurate reading may show in case these devices are sharing the same power line Insight Lite is classified as follows This device is I type BF grade device in terms of electric shock Itis improper to use this device nearby inflammable anesthetic and solvent IEC EN 60601 1 Safety of Electric Medical Equipment based noise making is A class IEC EN 60601 1 2 Electromagnetic Compatibility Requirements based noise proof is B level If you connect other devices to use RS 232C port you should use the devices which are satisfied with standard EN60601 1 Precautions for Use 11 FETAL MONITOR Ver 1 0 2 3 Maintenance and Cleanness You can maintain cleanliness on Insight Lite and its accessories including the probe in various ways Use the method provided below to avoid damage or contamination on the equipment If you
15. ay Hour Minute Step 1 Press the Setup key 277 on the basic screen If you press the Exit key J the present screen will returns to the basic screen Step 2 Press the Up Down key A V to move to the menu in the menu setting mode Move to the Record Alarm Volume and Time 36 Setting by Menu Function Insight Lite SETUP Step 3 Press the Enter key exten on the item desired to be set Then each relevant setting screen will be displayed The setting screen will be described in more detailed later AUTO Screen for Auto Print of Record Setting Step 4 Press the Up Down key A V to move to the detailed setting mode If you press the Exit key the menu will move to previous mode Step 2 If you press the Enter key lt the menu will move to detailed setting mode Step 5 Press the Enter key 4 222 in Step 4 and desired the level will be twinkled Then press the Up Down key A V for changing the level Step 6 After setting is completed if press the Exit key J menu will move to previous mode Step 2 without saving If press the Enter key 4 2327 menu will move to previous mode Step 4 with saving Step 7 After all setting is completed press the Exit key J to move to the basic screen Setting by Menu Function 37 FETAL MONITOR Ver 1 0 6 1 Record Setting Possible to set the printer relevant works Symbol Descrip
16. carried environmental protection 8 1 AC Power When the AC Power is connected to the device the AC Power LED on the front of the device will show a green light If the device is not in use it will revert to auto charge mode If the battery is connected by AC power LED for AC power will be lit and the battery will be charging automatically When charging is finished Insight Lite will be finished charging 8 2 BATTERY Power Optional automatically When you turn the power on without the AC Power connected the device uses the battery to operate When using the battery the BATTERY LED will show a green light In case battery power is short When the internal charge level of the battery is under 10 0V an information alarm will sound and bAt Lo will display on the Hi Low Auto Print FND If no management with low battery within 10 minutes the device will be turned off Before turning off the device connect AC power and charge the battery If the device is turned off with low battery message the device will not be turned on before connecting the AC power Charging Time 12 hours or longer Consecutive Using Time 6 hours when full charge Lithium Battery Used Only 54 Power Power 55 FETAL MONITOR Ver 1 0 CHAPTER 9 Simple Troubleshooting This chapter covers simple troubleshooting methods You may sometimes not be able to control the device as you want or may not know what to do with the device while us
17. er s Manual you shall notify it to us or any distributor who has the right to sell this product General 3 FETAL MONITOR Ver 1 0 WARRANTY PERIOD This product is made through strict quality management and test process This product can be repaired replaced or refunded in accordance with Consumer s Damage Compensation Regulation noticed by Economic Planning Board This product is warranted for 1 year If broken while being used normally this product will be freely repaired by our service center for such warranty period If you find any problem on the device please let us know the model name device number purchasing date and breakage content 4 Warranty Period Insight Lite SERVICE REQUEST The service for Medical Econet can be carried out by only Medical Econet Customer Service Dept or the person certified of such service by Medical Econet If the device is repaired or tried to be repaired by any person other than such certified person for the warranty period the warranty period shall be void Medical Econet Customer Service Dept or any distributor certified of Medical Econet Product Service is obligated to carry out any service requested by the user If you find any problem on the device or any risk on the human body in any hospital and place where the device is used the maintenance repair work shall be promptly and fully taken If you find any problem on the device take the actions as follo
18. evel will be twinkled Then press the Up Down key A V for changing the level Step 6 After setting is completed if press the Exit key 2 menu will move to previous mode Step 2 without saving If press the Enter key E _ menu will move to previous mode Step 4 with saving Step 7 After all setting is completed press the Exit key J to move to the basic screen 42 Setting by Menu Function Insight Lite 6 3 Volume Setting Possible to set the volume level for DOP1 and DOP2 respectively Symbol Description Setting Range DOP1 Sets DOP1 volume 0 7 Step EET n DOP2 Sets DOP2 volume 0 7 Step Initial setting 4 Step 1 Press the Setup key 4 275 to move to menu setting mode in the basic screen If you press the Exit key 1 menu will return to the basic screen Step 2 Press the Up Down key A V to move to the Volume menu in the menu setting mode SET UP Step 3 Press the Enter key Ener to move to the detailed setting mode Step 4 Press the Up Down key A V to move to desired setting mode among Auto Print Offset Zoom Speed Contrast and Fetal Movement If press the Exit key E menu will move SET UP to the previous mode Step 2 If press the Enter key 4 xe menu will move to the detailed setting mode of each mode Setting by Menu Function 43 FETAL MONITOR Ver 1 0 Step 5 Press the Enter key 4 sr in Step 4 and desired the level will
19. fer to clinical books together with this manual you product will expect more effects from using the device f you find any Problem while using please contact us or our A S Reservation Office 1 2 Contents The user must read the User s Manual before using the device This manual consists of the chapters as follow Chapter 1 How to use the User s Manual a Chapter 2 Precautions for Use Chapter 3 Overview of Insight Lite Chapter 4 How to install Insight Lite Chapter 5 How to use Insight Lite Chapter 6 Setting by Menu Function Chapter 7 Solution for Precaution and Warning Chapter 8 Use of Power Chapter 9 Simple Troubleshooting Chapter 10 Specification 6 How to Contact Us How to use the User s Manual 7 FETAL MONITOR Ver 1 0 1 3 Meaning of Symbols in the User s Manual We have marked on the user manual to emphasize the following agreements The user must follow all warnings and remarks In case of improper use or poor maintenance on the equipment resulting in product defect neither the manufacturer nor the distributor will be responsible for any damages WARNING is used to notify the possibility of critical injury death and physical and financial damage in case the warning is ignored PRECAUTION is used to notify the possibility of non critical injury in case the notice is ignored Note is used to notify users of not dangerous but very important information regarding
20. he fetus instead of the back the focus tends to often disrupt and you may not get an accurate reading If the fetus is facing up or down take extra caution to place the probe Place the probe around the patient s navel 2 Move the probe slightly around and locate the area where the fetus s heartbeat sounds the loudest and then use the belt to fasten the probe Do not adjust the volume until you have located an exact position with the probe Place the probe at the exact location that is an area where the heartbeat is heard loud and strong and the FHR heartbeat rhythm symbol blinks in sync with the fetus s heartbeat and then adjust the volume 28 How to use Insight Lite Insight Lite 3 When using the belt to fasten the probe make sure it does not slip As shown above the probe cable going up in the direction of the patient s head can prevent damage to the cable and the probe does not move as much 4 It is important to apply ample amount of Supersonic gel on the probe surface to get rid of air bubbles in between the abdomen and the probe 5 Insight Lite uses a Button Top styled DOP Probe Insert the protruding buttons on the opposite side of the DOP Probe surface to the Button Hole on the belt under the patient 6 It takes 4 to 5 seconds for the heartbeat to show Once a stable heartbeat is displayed the printing begins m UC Measurement UC measurement uses an external attachable pressure sensor Once the UC Probe i
21. ing the device At this moment check the followings instead of thinking It s broken System Performance Situation Checkpoint It is not powered AC power not plugged in Bad switch connection It does not work normally Unstable connection Badly grounded While measuring FHR I FHR II and UC Situation Checkpoint On HR measured value Check to see if the connection between the device and display part the Probe Connection Terminal is normal nothing is shown Check to see if the Probe is manufactured and provided from our company You must use the probe provided by us Check to see if the FHR II measurement setting is correctly done While the printer working Situation Checkpoint PAPER OUT Open the print door to make sure the paper is inserted correctly If there is no paper please install more printing paper For troubleshooting or repair please contact our Customer Service Dept or A S Reservation Office 56 Simple Troubleshooting Insight Lite CHAPTER 10 Specification Mechanical Base Unit Size 180mm W x 248 mm H x 175 mm D Weight less than 3 7Kg with paper Monitor Environmental Specifications Temperature Range Operating 10 to 45 C Storage 10 to 50 C Relative Humidity Range Operating 30 85 Storage 20 95 Atmospheric Pressure Range Operating 70 106kPa Storage 70 106kPa Power Specifications Power Requi
22. ions for Installation of Insight Lite Insight Lite shall be used at the ambient temperature of 10 45 and humidity of 30 85 Check the connection status of Power Cord Do not plug various cords into an electric consent Place the main body on flat place Ground it Otherwise noise may be made Do not use an electric cord that may generate noise Probe may be damaged by impact Do not get the Probe externally impacted nor submerge it in water or oil If Supersonic Probe used it must be used with Supersonic Gel After use wash it clearly and store it Install it considering the ambient temperature and humidity Keep it away from dusty or inflammable substances All configuration settings are stored without demonstration setting in the internal memory even after the device is powered off and then turned back on However if the device has not been used for over ten years or an external shock is applied to it the stored data may be altered and you must reconfigure the information 4 2 Installation of Main Body Insight Lite is designed to be easily used on a normal table cart or any other appliances commonly found in a hospital environment Normally you can use the handle in the back of the device and place it on a flat surface Since the center of gravity of the device is low key manipulation on the device will not topple it over It also does not slip 18 How to install Insight Lite Insight Lite
23. l turns on as red color after pressing the Print or Record key once And the FHR1 FHR2 UC and the Fetal Movement FM 1 FM 2 are recorded FM will not be recorded by the user s menu setting 2 If you press the Print key once again the red colored LED will disappears and the recording stops The Printer scrolls out 1 2cm of extra sheet after the recording has stopped 3 The FHR 2 graph can be printed 20bpm more than the FHR 1 area If you turn on the offset Offset indicator will turns on as green color m Auto Operation 1 Control the print time Print time is set by 10min 20min 30min 40min 50min 60min and off If you use OFF it will stop printing by press the Print button or out of paper 2 After finishing the setting by users it will apply to the initial printing This setting applies to the AUTO PRINT area This setting value is displayed the remained operation time m FHR 2 Offset Operation 1 Using 2 Probes simultaneously to measure FHR 1 2 and the value comes out similar is when it s most effective The Offset draws a graph by increasing 20bpm from the FHR 2 value 2 Before using the printer use the Up Down Enter key to turn the Offset On 3 Once the Offset On status is confirmed another 20 is added to the FHR 2 value After finishing the setting by users it will apply to the initial printing m ZOOM Operation 1 Use this function when you want to see the changes in the FHR more c
24. losely 2 When you select On in the Zoom category in the Print Setup the FHR area is expanded about 105 200 BPM than the normal range After finishing the setting by users it will apply to the initial printing 30 How to use Insight Lite Insight Lite SPEED Operation 1 Control the print speed 1cm min 2cm min and 3cm min 2 After finishing the setting by users it will apply to the initial printing CONTRAST Operation 1 Control the contrast of print by 3 step High number is thicker to print 2 After finishing the setting by users it will apply to the initial printing This setting does not apply during the printing This setting also applies to the graph area m FM Operation 1 FM record on the paper is decided by setting 2 After finishing the setting by users it will apply to the initial printing This setting does not apply during the printing This setting also applies to the graph area amp During printing you cannot change the printer setting If you want to change the setting you should stop to print Changed setting value without ZOOM is not changed even though you turn off the system Zoom is initialized after turning off m Reading the Recorded Sheet Press the Print key once to begin recording and the sheet ejects as described below The recording areas are divided into two main categories the text area and the graph area The text and graph show as soon as the p
25. p 5 Press the Enter key 4 2 in Step 4 and desired the level will be twinkled Then press the Up Down key A V for changing the level Step 6 After setting is completed if press the Exit key 4 menu will move to previous mode Step 2 without saving If press the Enter key menu will move to previous mode Step 4 with saving Step 7 After all setting is completed press the Exit key 2 to move to the basic screen Setting by Menu Function 47 FETAL MONITOR Ver 1 0 6 5 Default Setting Every basic parameter except for time on the device is initialized Step 1 Press the Print key UC REF key at once in the turning the device off condition Step 2 Turn on the device with pressing the above keys All basic parameter except for time is initialized If initialized the screen will be like below ON Je 20bpm SPEED cm min OS OW OR AUTO PRINT Step 3 Then turn on the device without pressing the keys All parameter is initialized 48 Setting by Menu Function Insight Lite CHAPTER 7 Solution for precaution and warning Error Code Code Description El No paper or paper out during printing E2 Disconnected DOP1 from DOP connection part during using Disconnected DOP2 from DOP2 connection part during using E3 If E2 error occurs it will not be displayed p Disconnected UC from UC connection part during using If E2 and E3 error occurs it
26. p Enter Enter the menu mode or save the setting 24 How to use Insight Lite Insight Lite a Lamp ACLED 9 l K E j SETUP BATTERY NN igi Cy v ENTER LED The LED located on the key area of the front face Panel displays the status of the used Power 1 AC Power LED lights up while AC Power being used 2 Battery Optional LED lights up while Battery Power being used Alarm Lamp SILENCE medical The LED located on the top of the front face Panel displays Alarm and Heart Rate Rhythm 5 5 Measurement of FHR and UC Apply ample amount of Supersonic Gel on the surface of the Probe The DOP and UC Probe used in Insight Lite previous models are designed to be used under water Doppler and UC probes are applied by IPX7 so they can be used for the underwater delivery in the water How to use Insight Lite 25 FETAL MONITOR Ver 1 0 Probe Connection Connect DOP1 DOP2 and UC probes at the left side of the device There are 2 Doppler probes and you may connect them to any one of the DOP1 DOP2 and UC Terminals When diagnosing twin fetus connect both terminals Basic Screen by Probe Connection If the DOP Probe is not attached nothing shows on the screen where the heart rate is displayed and no sound or heart symbol signal shows If the DOP Probe is attached but not used the status is Stand By and heartbeat area shows until the diagnosis starts When the diagnosis starts
27. rements 100 240V AC 50 60Hz 1 0A Power Fail Protection Battery Specifications Sealed Rechargeable Battery 11 1V 4 4Ah Li ion Battery Operation Time about 6 hours Charge Time after connection to AC power about 12 hours Class 1 Equipment Monitor Performance Specifications Doppler Pulsed Doppler Ultrasound Frequency 2 0 MHz Intensity lt 10mW cm2 FHR Range 50 240 bpm FHR Accuracy 2 of range Dual Doppler Specification 57 FETAL MONITOR Ver 1 0 Dual Fetal Movement Detection IPX7 UC External Type Frequency Response DC 0 5 Hz Reference Zero Control Measurement Range 0 99 units IPX7 Printer 4inch Thermal Array Type Print Speed 1 2 3 cm min Print Contrast 1 2 3 steps Auto Print Period 10 20 30 40 50 60 0ff min FHR Print Area Zoom Function FHR 2 Offset Function FM On Off Function ROLL Type Paper Indicators Battery On orange LED optional AC Power green LED Display Printing State Offset State Speed State Auto Print Time Heart Rhythm FHRI DOPI Value FHR2 DOP2 Value UC Value Bar 58 Specification Sound Doppler Sound with Volume Control Information Sound Alarms Sound Key Sound External Link RS 232 port Standard Accessories Ultrasound Doppler Probe UC Probe Event Marker Jack Print Paper Power cord ADAPTER JACK 220 TO 110 Ultrasound Gel Probe Belt Operation Manual Optional Accessories Cart AST Probe
28. ring the silence situation medicalECONEL AUTO PRINT AUTO PRINT 34 How to use Insight Lite Insight Lite 5 10 Sound 1 Doppler Sound This is the Doppler sound of the fetus s heartbeat The volume of this sound can also be adjusted using the Volume Key 2 Alarm Sound When a measured HR value exceeds the set range the beep will sound repeatedly 3 INFORMATION When a probe is disconnected or the battery is low or the printer door is ajar and when the printing paper is missing a ding dong sound will repeat 4 The alarm sound and information sound cannot be adjusted 5 11 AST Optional This function is for waking up the baby Insight Lite is designed to use AST to connect DOP 2 Probe connector Insight Lite shows AST on the FHR2 area REC 20bpm SPEED cm min OS EMOP OR AUTO PRINT Press the button on the AST probe on the patient s abdomen It makes sound for waking up the baby Please do not close this device to the ear It makes you harmful DO NOT CLOSE THE DEVICE TO THE EAR How to use Insight Lite 35 FETAL MONITOR Ver 1 0 CHAPTER 6 Setting by Menu Function Menu cannot be set on the volume control mode Setup Key 4 E changes various setting values as follow Record Sets the printer status Printer Relevant Setting Value Alarm Alarm Sound Making Range Volume Sets the volume level of FHR1 and FHR2 Time Sets time Year Month D
29. rinting begins The text is repeated at paper top area on 10 minute and is included the setup value of print 1 Date 2 Time 3 Status of DOP 1 DOP 2 Probe and UC Probe 4 Status of FM 5 Print Speed 6 Status of Offsset and 7 Status of ZOOM How to use Insight Lite 31 FETAL MONITOR Ver 1 0 5 8 Volume Control The volume can be adjusted in 8 levels and there are two ways to control it One is to use the SETUP key and control it from the menu and the other is to use the volume key The volume of Doppler I and II can be adjusted Volume Change in the Menu 1 Press the SETUP key 4 e to move the menu setting mode AUTO 2 Press the Up Down key A V to move the volume menu AUTO 3 Press the Enter key e to enter the volume control area 4 Press the Up Down key A V for changing the volume HR1 or HR2 and then press the Enter key em The volume level will be twinkled in the LOW area 5 Press the Up Down key A V to control the volume during twinkling 32 How to use Insight Lite Insight Lite 6 Press the Enter key 2727 or Exit key Q at the desired level and the volume control operation is complete If you press the Enter key the desired level will be saved and move to menu 3 If you press the Exit key the volume level will be returned to previous level and move to menu 2 7 You can change the volume level of DOP1 and
30. s placed on the patient s abdomen the pressure fluctuation of the patient s uterus enables the contraction level 1 Place the belt underneath the back of the patient 2 Place the UC Probe on the highest point of the patient s belly Fundus Usually about 10 cm above the navel or the point on the patient s belly where it has become the first place to harden up 3 Insert the protruding buttons on the opposite side of the UC Probe surface to the Button Holes on the belt under the patient The recommended tightness on the fastening of the belt is from 20 to 90 4 If the UC Probe is attached but not in use a meaningless number displays on the screen When using the UC Probe press the Reference key to reset the default value of 10 on the front panel before use Insight Lite shows the LED bar of uterine contraction level 5 Once a stable UC value is found the printing begins 5 6 How to use Event Mark The purpose of the marking is to record the moment when the patient senses the start of the fetal movement When you press the Mark switch during printing an arrow shows on the printing paper Mark Jack is connected to the left connection terminal of the device How to use Insight Lite 29 FETAL MONITOR Ver 1 0 5 7 How to use Printer The printer used in Insight Lite is a 4 inch Porti M400V made by Wooshim System It uses 9V Power and the width of the printing paper is 112mm m Printer Operation 1 REC indicator wil
31. tion Setting Range Auto Print Automatically records during the set time 10 20 30 40 50 while printing 60 OFF min Initial setting OFF Offset If this function is selected HR value of ON OFF HR II will be recorded adding 20bpm Initial setting OFF Zoom Extends FHR recording area of PRINT record paper If this function is selected FHR area of the record paper will change from the range of 50 240bpm to the range of 105 200bpm ON OFF Initial setting OFF Speed PRINT Speed 1 2 3 cm min Sed Initial setting 3cm min CONTRAST PRINT CONTRAST 1 2 3 steps can Initial setting 2 Fetal Movement Print Fetal Movement ON OFF 38 Setting by Menu Function Initial setting ON Insight Lite Step 1 Press the Setup key 4 to move to menu setting mode in the basic screen If you press the Exit key J menu will return to the basic screen Step 2 Press the Up Down key A V tomove to the Record menu in the menu setting mode SET UP Step 3 Press the Enter key 4 wren to move to the detailed setting mode Step 4 Press the Up Down key A V to move to desired setting mode among Auto Print Offset Zoom Speed Contrast and Fetal Movement If press the Exit key menu will move to the previous mode Step 2 If press the Enter key J menu will move to the detailed setting mode of each mode Setting by Menu Function 39 FETAL MONITOR Ver 1 0 Insight
32. use materials that can damage the product non approved cleaning material the warranty will be voided After cleaning the device check the main body and the sensors very carefully If the device is overused and damaged do not use it Using warm water clean the main body with alcohol on a soft cloth at least once a month and do not use lacquer thinner ethylene and acidic cleansers These materials can damage the device The cable and accessories must be maintained to avoid contact with dirt and wiped down with warm water approximately 104 F on a cloth pad and use alcohol to clean it once a week Do not dowse the connection parts of the accessories in liquid or detergent Also no liquid must go in the connection part of the device or the accessories 12 Precautions for Use Insight Lite CHAPTER 3 Overview of Insight Lite 3 1 Principle and Features of Insight Lite Insight Lite is a Fetal Monitor which basically measures the fetus s heart rate and the patient s uterus shrinkage Insight Lite sends supersonic signal to the patient s abdomen and then measures the signal returned from the fetus s heart It then sorts out the Doppler frequency from the returned signal and converts it into the heart beat of the fetus The signal is then analyzed and displayed as the fetus s heartbeat and printed out on a printer The patient s contraction level of uterus can be measured with pressure sensors as well as printing out the
33. w Please immediately contact our Customer Service Dept or any distributor representing us for our service Check the model name product number purchasing date problem or question to ask before contacting us Our Customer Service Dept will check and solve the problem online first If difficult to solve the problem online it will visit you to solve the problem immediately Service Request 5 FETAL MONITOR Ver 1 0 Insight Lite HOW TO CONTACT US CHAPTER 1 How to use the User s Manual 1 1 General This device provides you with the exact and stable values fetus s heart rate patient s uterus shrinking level and etc measured on the patient and fetus and correct information of the Customer i MEDICAL ECONET fetus s status Center Im Erlengrund 20 46149 Oberhausen Germany This manual covers Insight Lite a Fetal Monitor manufactured by Medical Econet which is Tel 49 208 377 890 00 designed for maximal user s convenience This manual consists of independent chapters Fax 49 208 377 890 55 Some information is specified several times here in this manual This manual is a guidebook for efficient use of Insight Lite For clinical and pathological Before making reservation on troubleshooting please check the model information about the device please refer to basic relevant medical books Then you will use name serial number purchasing date and abnormality of the damaged the function of the device better If you re
34. will not be displayed Low Battery Low E5 Ty If E2 E4 error occurs it will not be displayed 7 1 Solution for Alarm sound and Message When the values go over or below the Alarm range over 10 seconds the beep will sound The color of alarm LED lamp will be changed green to red The FHR will be also twinkled If you want to turn off the alarm press the SILENCE key 7 2 Solution for Information sound and Message 1 The beep sounds once like ding dong as information sound when turn on the device Solution for precaution and warning 49 FETAL MONITOR Ver 1 0 2 The beep sounds ding dong every 5 minutes when no paper until error is released or press the Exit key Error message will be displayed in Hi Low and Auto Print FND until error is released 3 The beep sounds ding dong every 5 minutes when probe is disconnected during using until error is released or press the Exit key Error message will be displayed in Hi Low and Auto Print FND until error is released 4 The beep sounds ding dong every 5 minutes when the battery is low until error is released or press the Exit key Error message will be displayed in Hi Low and Auto Print FND until error is released 5 Display for each error Probe is disconnected during using Display Pro oFF and d 1 d 2 Uc with error code by turns in each disconnected probe Probe is disconnected with no paper Display PA
35. y the configuration Refer to 6 Step 7 If you want to wake up the baby during measuring please remove the Doppler from DOP2 and connect AST probe optional Then press the button on the AST probe on the patient s abdomen It makes sound for waking up the baby Please do not close this device to the ear It makes you harmful DO NOT CLOSE THE DEVICE TO THE EAR 22 How to use Insight Lite Insight Lite 5 3 Basic Screen 1 Displays Value of FHR 1 2 Displays Heart Rate Rhythm of FHR 1 3 Displays Heart Rate Rhythm of FHR 2 4 Displays maximum limit of Alarm Level 5 Displays Value of FHR 2 or Connecting Status of AST probe 6 Displays minimum limit of Alarm Level 7 Indicates bar graph of measured UC value 8 Displays measured UC value 9 Printer Status 10 Offset Setting Status 11 Printing Cycle for Printer Auto Printing Indicate remain print time during printing How to use Insight Lite 23 FETAL MONITOR Ver 1 0 5 4 Function of Keys 0 O a A td A V Sitter Keys on Front Face 1 Print Used as Print On Off Key 2 Reference used to set UC value as the standard value 10 3 iq Volume switch to the volume level 4 R Exit Back to the previous default screen from the menu status 5 A Up Change to the mode or value in the menu mode 6 v Down Change to the mode or value in the menu mode SET UP ENTER 7 Setu