1. power resources connect the 6 pin PCI Express power resource provided by NA260A to the 6 pin PCI Express power connector on graphics card or connect the 6 2 pin PCI Express power resource provided by NA260A to the 8 pin PCI Express power connector on graphics card 8 a _ WE e m 4 Place the top cover back to TurboBox Rac NA260A and tighten the two thumbscrews to fasten the top cover Step 4 5 Connect the end of PCle x8 cable to PCle x8 connector on rear panel of TurboBox Rac NA260A Also connect the end of power cord to power receptacle on TurboBox Rac NA260A and the other end of power cord to a grounded outlet or power strip Note there are three hot swappable 120x120 25 mm cooling fans for ventilation inside TurboBox Rac NA260A You may simply draw the cooling fans out by pulling the L type metal handle on the fan modules Q Fan Speed Adjustment You are able to adjust the speed of 120x120x25 mm cooling fan inside TurboBox Rac NA260A To do so pull the cooling fan out and you will see five sets of jumpers labeled with F 1 2 3 and 4 respectively from left to right on the board The default setting is the jumper being placed over pin 9 and pin 10 for label 4 meaning the slowest speed of fan If the jumper is placed over pin 1 and pin 2 for label F the fan will spin at full soeed From label 1 to label 3 the fan speed decrease
2. NETSTOR T ae r E ie f ELES a Quick Installation Guide External PCle to GPU Enclosure MEF FSP Ov NA260A Version 1 0 6F No 1 Alley 16 Lane 235 Baogiao Rd Xindian District New Taipei City 231 45 Taiwan R O C Netstor Technology Co Ltd Tel 886 2 2917 1500 Fax 886 2 2918 1260 E mail sales netstor com tw NAZ60A Rackmount External PCle to GPU Enclosure Panel layout Gi Overview The easy and cost effective Netstor PCle to PCle expansion system TurboBox Rac NA260A features easy plug and play installation containing PCle 2 0 x8 host card and data cable for up to 40 Gbps high speed transfer rate The TurboBox Rac NA260A is configured by the BIOS from the workstation or server automatically which makes all the PCle slots on TurboBox Rac NA260A available to the server or workstation O Package checklist Before the installation of this unit verify the package contains the following items TurboBox NA260A x 1 PCle 2 0 x8 host adapter with standard and low profile bracket x 1 PCle 2 0 x8 cable 1 5 meter x 1 Power cord x 1 CD containing user manual x 1 O oO NOU 432 1 5 6 7 8 9 Power on off button Blue power on Note To power on off the TurboBox Rac NA260A press the button for two seconds Buzzer mute button Fan LED Green normal Red fan failure low frequency of RPM or stop Temperature LED Gree
3. Update Processor 2 x 2 26 GHz Quad Core Intel Xeon Memory 6 GB 1066 MHz DDR3 Startup Disk Macintosh HD TM and 1983 2010 Apple Inc All Rights Reserved Click More Info from the window Software Update Mac OS X Software System Preferences Dock Recent Items Log Out Nelson Click PCI Cards from the left side of the window and when there is no third party PCle graphics card plugged in TurboBox Rac you will see six pci bridges that indicate six PCle slots on TurboBox Rac Mac Pro LIE PS ee E Skt 10 he ra PO Ske PC to PO Gage Yeu POL Skt 2p7 4 0 Pa Pa ra Pa When a third party PCle graphics card is plugged in one of the PCle slots on TurboBox Rac the third party PCle graphics card will be shown under the six pci bridges Mac Pro Tehon Mar Fro HOLUM FTES Bet 2H7 4 0 Bee 207 2 0 Sot 207 2 0 Set 2H7 2 0 Sct 207 2 0 Sa 296 2 0 mr F EUSRRI ESE HIH g 5 HHE HE ii ALLL aaaaeaaaF PCi to l Bridge Yes Conotecs Cort When the driver of the third party PCle graphics card is installed on Mac OS X your server or workstation will begin working with the third party PCle graphics card on TurboBox Rac NETSTOR Netstor Technology Co Ltd 6F No 1 Alley 16 Lane 235 Baogiao Rd Xindian District New Taipei City 231 45 Taiwan R O C Tel 886 2 2917 1500 Fax 886 2 2918 1260 E mail sales netstor com tw
4. n normal Red overheated higher than 55 C Power switch Power receptacle 60x60 x25 mm hot swappable cooling fan External PCle x8 connector for host connection PCle slots 10 Thumbscrew to loosen tighten the side door 7 654321 1 23456 Slot1 PCle Slot2 PCle Slot3 PCle Slot4 PCIe Slot 5 PCle Slot 6 PCle NO UU BWYN x16 connector x8 signal x16 connector x8 signal x4 connector x4 signal x16 connector x8 signal x4 connector x4 signal x16 connector x8 signal 8 x 6 2 pin PCI Express power connectors for graphics cards To server or workstation the speed of the PCle slots on NA260A runs at PCle x8 40 Gbps Installation of PCI Express Add On Graphics Card Before following the installation procedures disconnect TurboBox Rac NA260A from power source to prevent electric shock or damage to add on graphics card 1 First loosen the two thumbscrews and remove the top cover from TurboBox Rac NA260A Step 1 2 Bend the L shape metal bracket on rear panel of TurboBox Rac NA260A for preparation of the installation of PCle add on or graphics card Step 2 Note it is easier to use a screwdriver to bend the L shape metal bracket NAZ60A Rackmount External PCle to GPU Enclosure 3 Insert a PCle add on graphics card into PCle x16 slot and tighten it with a screw If you are installing a graphics card that requires extra
5. rosoft ACPI Compliant System open PCI bus click PCI Express Root Port click PCI standard PCI to PCI bridge and click again PCI standard PCl to PCl bridge And then you will find your third party PCle graphics card under PCI standard PCI to PCl bridge Note You may see PCI Express Root Ports with different ending numbers such as 2E21 2E29 and 2E20 These different ending numbers indicate different PCle slots on motherboard ees You will see six PCI standard PCI to PCl bridges below the PCI Express Root Port Note If there is a yellow exclamation mark in front of the third party PCle graphics card under PCI standard PCI to PCl bridge it means the third party PCle graphics card is without the driver so you have to install its driver on operating system to make it work with the server or workstation After the driver is installed on operating system the third party PCle graphics card will work properly with the server or workstation via TurboBox Rac and the name of the third party PCle graphics card will be shown under PCI standard PCl to PCI bridge furthermore the name of the third party PCle graphics card will also be shown in the list of Device Manager GE ATALA cortrnters amp TLE 1 Bs hot cortroiers gt Unbowds For Mac OS To verify a successful installation on Mac OS X select About This Mac under the Apple icon 0o00 About This Mac a z Mac OS X Version 10 6 4 Software
6. s If all of the pins are open meaning no jumper is placed over the pins the fan will not spin 1 gt 5 7 9 Switch of Gen1 Gen2 and Switch of Power on off by Host and Power on off by Manual There are two switches labeled SW1 1 and SW1 2 respectively at the bottom side of the backplane of NA260A as shown in the following picture SW1 1 manages setting of Gen1 Gen2 of PCI Express while SW1 2 controls setting of power on off by host and power on off by manual To switch PCI Express to Gen1 switch SW1 1 to ON position to switch PCI Express to Gen2 switch SW1 1 to OFF position If you wish your NA260A to be powered on off by host or server switch SW1 2 to ON position If you wish to power on off your NA260A manually switch SW1 2 to OFF position TA ON GEN OFF GEN2 amp Installation of Host Adapter and Cable Connection Before following the installation procedure disconnect the server or workstation from power source to even Bone shock or damage to add on graphics card 1 Install Netstor TurboBox Rac PCle 2 0 x8 host adapter into an available PCle x8 connector compatible with x16 connector in server or workstation Secure the host adapter with a screw motherboard 2 Connect the other end of PCle x8 cable to TurboBox Rac PCle 2 0 x8 host adapter on server or workstation a 8 Power On TurboBox Rac NA260A Power on the TurboBox Rac NA260A by pre
7. ssing the power button for two seconds Power On Server or Workstation In order to let the BIOS of server or workstation identify and assign resources appropriately make sure to power on Netstor TurboBox Rac NA260A first and then power on server or workstation There is no software required for proper configuration of Netstor TurboBox Rac by server or workstation s operating system however as a third party PCle card is installed in TurboBox Rac a request for the driver of the third party PCle card will be prompted by the operating system Please follow the instruction provided by the third party PCle card Remove TurboBox Rac from Server or Workstation To remove TurboBox Rac NA260A from server or workstation power off server or workstation first and then power off TurboBox Rac 11 Verify Installation For Windows operating system When you want to verify a successful installation on Windows operating system go to My Computer and right click the icon of My Computer Select Manage from the menu see figure 10 1 and click Device Manager in the left side of window of Computer Management see figure 10 2 NAZ60A Rackmount External PCle to GPU Enclosure Figure 10 1 SB cpus Paragon Let z j hia Tooke H cpie E a Dick cries E i TE ATAPATAR controllers Figure 10 2 And then click View from the top side of the window and select Devices by connection Open ACPI Multiprocessor PC open Mic