1. Y as Ep Ep a sam Step 2 Step 1 Fig 2 1 PRESET selection with DIRECT SELECT disabled 2 1 2 DIRECT SELECT activated If DIRECT SELECT is on do as follows to select PRESET 1 from BANK 3 activating DIRECT SELECT is discussed in ch 2 2 1 Step 1 Select the BANK of your choice here BANK 3 by stepping on footswitch 3 Step 2 Selectthe PRESET you wish to use here PRESET 1 by stepping on footswitch 1 The display shows that preset 31 is selected 2 PROGRAMMING THE FCB1010 MIDI FOOT CONTROLLER FCB1010 C31010 MIDI FOOT CONTROLLER NL 3 Step 2 Step 1 Fig 2 2 PRESET selection with DIRECT SELECT enabled As this example shows the DIRECT SELECT feature gives you a faster access to BANKS and PRESETS than without this function Which option to use is entirely up to you As long as you need the PRESETS from one BANK only it will be advisable to disable the DIRECT SELECT function because this way you can recall a new preset with only one keystroke 2 2 GLOBAL CONFIGURATION In the GLOBAL CONFIGURATION menu you can set the parameters that apply to both the PRESETS and FUNCTIONS of your FCB1010 e g MIDI channel selection SYSEX SEND amp RCV DIRECT SELECT etc Keep the DOWN switch pressed during power up for about 2 5 sec to enter GLOBAL CONFIGURATION mode The DIRECT SELECT LED in the disp
2. 7 WARRANTY 1 WARRANTY CARD ONLINE REGISTRATION To be protected by the extended warranty the buyer must complete and return the enclosed warranty card within 14 days of the date of purchase to BEHRINGER Spezielle Studiotechnik GmbH in accordance with the conditions stipulated in 3 Failure to return the card in due time date as per postmark will void any extended warranty claims Based on the conditions herein the buyer may also choose to use the online registration option via the Internet www behringer com or www behringer de 2 WARRANTY 1 BEHRINGER BEHRINGER Spezielle Studiotechnik GmbH including all BEHRINGER subsidiaries listed on the enclosed page except BEHRINGER Japan warrants the mechanical and electronic components of this product to be free of defects in material and workmanship for a period of one 1 year from the original date of purchase in accordance with the warranty regulations described below If the product shows any defects within the specified warranty period that are not excluded from this warranty as described under 3 and 4 BEHRINGER shall at its discretion either replace or repair the product using suitable new or reconditioned parts In the case that other parts are used which constitute an improvement BEHRINGER may at its discretion charge the customer for the additional cost of these parts 2 If the warranty claim proves to be justified the product will be returned to the user f
3. A If you want to copy further presets please press footswitch 5 again Press and hold DOWN ESCAPE to quit the GLOBAL CONFIGURATION 2 4 2 Programming switches A Select the PRESET you wish to edit A Press DOWN for more than 2 5 sec to enter PRESET programming mode The green SWITCH 1 SWITCH 2 LED in the display starts flashing A Enable disable the SWITCHES using footswitches 1 and or 2 and confirm your selection with UP ENTER The corresponding footswitch and SWITCH LEDs light up A Exit PRESET programming mode through keeping the DOWN ESCAPE key for a few seconds or press the UP ENTER key in order to get to the next page where you can edit various MIDI functions for the preset selected at the beginning 2 4 3 Programming program changes A Select the PRESET you wish to edit A Keep the DOWN ESCAPE key pressed longer than 2 5 sec to get to the programming mode The green SWITCH 1 SWITCH 2 LED in the display starts flashing A Use the UP ENTER key to get to the next page The SELECT LED in the display is lit 2 PROGRAMMING THE FCB1010 gt gt it Individual MIDI functions are activated by keeping the corresponding keys pressed for a few seconds Active MIDI functions are indicated by a permanently lit footswitch LED Select the PROGRAM CHANGE you wish to program for the selected PRESET by briefly pressing the respective footswitch footswitches 1 to 5 The footswitch LED blinks Confirm your selection by pre
4. FCB1010 too can send NOTE ON messages however in a different context many effects devices allow for tapping delay times etc by measuring the time interval between two NOTE ON messages With the FCB1010 you can tap delay times or song tempos by selecting a NOTE PRESET twice NOTE ON and NOTE OFF messages feature the following data format Status Byte Data Byte 1 Data Byte 2 Note Off amp 8n n channel Velocity amp 9n n channel Velocity Tab 4 1 Data format of NOTE ON and NOTE OFF messages The channel number range is 1 through 16 the data byte range is O through 127 It should be noted though that NOTE OFF messages are not so common today for reasons of data reduction cf running status Usually NOTE ON messages with zero velocity are transmitted instead The FCB1010 follows this convention By the way when you program the NOTE function on your FCB1010 you only need to enter the note number because notes are always transmitted with a velocity of 64 4 2 2 CONTROL CHANGE messages CONTROL CHANGE messages are the most powerful MIDI messages as they allow you to select and automate plenty of parameters and functions On your FCB1010 you can define and transmit CONTROL CHANGE messages e g to change specific effects parameters in real time The most important CONTROL CHANGE messages are volume control Controller 07 Balance 08 Panorama 09 and reverb intensity 91 4 2 3 P
5. PEDAL A to enter the controller value 0 through 127 To correct your selection use the DOWN ESCAPE key to go one step backward Confirm your selection by pressing UP ENTER The SELECT LED in the display lights up Select an additional MIDI function you wish to edit or quit the PRESET programming mode by keeping DOWN ESCAPE pressed for a few seconds 2 4 5 Programming EXPRESSION PEDALS A B Select the PRESET you wish to edit Keep DOWN pressed for more than 2 5 sec to enter PRESET programming mode The green SWITCH 1 SWITCH 2 LED in the display starts flashing Use UP ENTER to get to the next page The SELECT LED in the display begins to light up To program a MIDI function you have to first activate it Individual MIDI functions are activated by keeping the corresponding keys pressed for a few seconds Active MIDI functions are indicated by a permanently lit footswitch LED MIDI FOOT CONTROLLER FCB1010 A Activate the expression pedal you wish to program by keeping the corresponding foot key pressed for a few seconds foot keys 8 or 9 The foot key LED blinks after you briefly press the foot key yet again A Confirm with UP ENTER The NUMBER LED lights up A Enter the control nunmber 0 bis 127 via the footswitches or the expression pedal A A Confirm your selection with UP ENTER The VALUE 1 LED lights up A Enter the value to be transmitted when the pedal is completely open by using the foot keys or the expressio
6. 281010 i MIDI FOOT CONTROLLER FCB1010 0 Fig 3 1 Basic setup with a guitar amp Here the FCB1010 is used to control a guitar amp that is equipped with a MIDI interface Connect the MIDI OUT jack of your FCB1010 to the MIDI IN of your amp see fig 3 1 using a standard 5 pole MIDI cable Program your FCB1010 as described in chapter 2 4 Please refer to the user s manual of your amp to find out what functions can be controlled via MIDI 3 2 Expanded setup using the switch function FX Return Footswitch In Midi In T VIRTUALIZER PRO DSP2024P BEHRINGER BLUE DEVIL Gx112 I ES55100 M Midi Out _ Switch 1 MIDI FOOT CONTROLLER FCB1010 Fig 3 2 Guitar setup using the switch function Here the FCB1010 is used to control an effects device via MIDI In addition the switch function is used to toggle between the two channels clean overdrive of the guitar amp Please connect your effects device via the FX send return loop of your amp Now connect the SWITCH 1 connector with the footswitch input of your guitar amp Use a standard jack cable for this purpose Connect the MIDI OUT connector of the FCB1010 to the MIDI IN connector of the effects device using a standard MIDI cable The effects processor is controlled via MIDI while the SWITCH function toggles the amp Thus you ll need no additional footswitch when you switch between the ch
7. Chart Trans n Function tea Fecognized Remarks Basic Default 1 16 Channel Changed D Mode efault Messages Note Erz BE X X programmable Number wie O gt 1 128 i a After Keys x Touch Channels E D oiz x 3 Change 1 128 Active Sense x x x Reset Soft Thru Merge rd O YES X NO Mode 1 OMNI ON Mode 2 OMNI OFF Note ON velocity Note OFF True Exclusive ong Pos Song Sel Tune Clock Real Time _Commands System Aux Local ON OFF Messages All notes OFF Tab 5 1 MIDI Implementation MIDI INTERFACE Type DISPLAY Type SWITCHING OUTPUT Type POWER SUPPLY Voltage Power consumption Fuse Mains connection DIMENSIONS WEIGHT Dimensions H x W x D Weight 5 pin DIN jacks IN and OUT THRU 3 digit LED 1 4 jack open USA Canada 120 V 60 Hz Europe U K Australia 230 V 50 Hz Japan 100 V 50 60 Hz General export model 120 230 V 50 60 Hz 10W 100 120 V T 100 mA H 200 240 V T 50 mA H Standard IEC connector approx 2 3 8 60 mm x 27 687 mm x 8 3 4 221 mm approx 3 5 kg 7 71 Ibs BEHRINGER is constantly striving to maintain the highest professional standards As a result of these efforts modifications may be made from time to time to existing products without prior notice Specifications and appearance may differ from those listed or illustrated 6 SPECIFICATIONS 15 MIDI FOOT CONTROLLER FCB1010
8. example you can control several pieces of equipment from your FCB1010 The selection of MIDI functions is done via footswitches 1 to 10 0 MIDI channel 1 is the factory default for all functions Switch _wiDifuneton 6 ori 8 Exea 9 EPB Tab 2 1 Footswitches and assigned MIDI functions A After selecting a MIDI function by pressing one of the footswitches the respective footswitch LED starts to blink A Press UP ENTER to confirm the selected MIDI function The MIDI CHAN LED lights up A Choose the MIDI channel for the selected function either directly via footswitches 1 through 10 0 or by using the EXPRESSION PEDAL A Your selection is shown in the display A Press UP ENTER to confirm the chosen value and to go to the next level or press DOWN ESCAPE to cancel 2 2 3 CONFIG page The CONFIG LED lights up if you are on CONFIGURATION page The following functions recalled via the footswitches as in table 2 2 are at your disposal MIDI FOOT CONTROLLER FCB1010 program change commands two controller commands two different controller values using the expression pedals and a Note On command to the connected equipment at the same time menu structure as in fig 2 4 It is up to you to determine which commands are stored ina PRESET Do as follows to program the functions to be sent with each PRESET Switch Function Action Determines if UP key toggles 1 SWITCH 1 SWITCH 1 relay while DIRECT SELEC
9. no MIDI connection is present If you connected MIDI Out to MIDI In the display shows A1 In this case the MIDI connections operate correctly A Press DOWN ESCAPE once A Move the expression pedal A to the lowest value possible pedal open The VALUE 1 LED lights up When the value is adjusted press the UP ENTER key A Move the expression pedal A to the highest value possible pressed down all the way The VALUE 2 LED lights up When the value is adjusted press the UP ENTER key A Move the expression pedal B to the lowest value possible When the value is adjusted press the UP ENTER key A Move the expression pedal B to the highest value possible When the value is adjusted press the UP ENTER key Both pedals are now correctly calibrated 3 APPLICATIONS Several application examples that should help you with the MIDI setup are described in this chapter As long as your equipment features MIDI connectors you can control it entirely via the FCB1010 All you need is a MIDI IN connector at the other end No audio signal pass through the FCB1010 and consequently no signal processing takes place in it either The FCB1010 merely transmits control data to your MIDI equipment so it can for example call up presets turn effects on or off or adjust volume You can find more detailed information on this subject in chapter 4 MIDI A STANDARD A REVOLUTION 3 1 Basic setup Midi In BLUE DEVIL 6X112 Midi Out KT
10. toggle between the preprogrammed SWITCH settings each time you step on these switches 3 EXPRESSION PEDAL A Allows you to change controller values continuously In programming mode the pedal is used for data entry 4 EXPRESSION PEDAL B Allows you to change controller values continuously 5 STATUS LEDs The yellow LEDs display the current status of the PRESET programming or GLOBAL CONFIGURATION functions 6 LED display Informs you about the currently selected BANK PRESET number In programming mode it displays any value changes MIDI FOOT CONTROLLER FCB1010 1 3 2 Rear panel 7 POWER LT glk Fig 1 2 Rear panel connectors SERIAL NUMBER DATE CODE FUSE HOLDER VOLTAGE SELECTOR Please make sure that your local voltage matches the voltage indicated on the unit before you attempt to connect and operate the FCB1010 Blown fuses may only be replaced by fuses of the same type and rating Some models allow for inserting the fuse holder in two different positions in order to switch over from 230 V to 120 V operation and vice versa Please note that for 120 V operation outside Europe you need to use a fuse of a higher rating see chapter 6 SPECIFICATIONS IEC POWER CONNECTOR Use the enclosed power cord to connect the unit to the mains Use the POWER switch to power up your FCB1010 Always make sure the POWER switch is in its O
11. your selection with UP ENTER The NUMBER LED lights up A_ Enter the maximal possible delay time value for the equipment you wish to control Calculate the value that is to be entered for NOTE by dividing the maximum delay time value by 10 ms Confirm your selection with UP ENTER The SELECT LED lights up 13 Please note that the FCB1010 allows for a maximum delay time of 1 270 ms which is due to the MIDI standard s maximum resolution of 7 bits 128 values A Activate control change 1 CNT 1 by keeping the footswitch 6 pressed for a few seconds The footswitch LED lights up and is activated by briefly tapping the footswitch the LED blinks A Press UP ENTER again Now the FCB1010 prompts you to enter a controller number The NUMBER LED lights up Enter the controller number which the manufacturer of your effects device has preset for delay time changes Confirm your selection with UP ENTER The VAL1 LED lights up A The VALUE to be entered now corresponds to the upper limit of the parameter range determined by the controlled device That might sound a bit confusing but it s quite easy the manual that came with the device usually contains an effects table listing the parameter range to be input via MIDI in order to control the delay time For example the device might use the entire range from O through 127 or a limited range from O through 63 and so on So the VALUE parameter simply determines the resolution with whic
12. 11 2 6 TAP TEMPO function a 11 2 7 Data storage nenne este 11 2 7 1 Saving the FCB1010 memory with the help Of SysEx GUMS irei de erreen areenan 11 2 7 2 Receiving SysEx dumps ceneneenennen 12 2 8 Restoring factory presets neneseneenesennennennenen 12 2 9 Calibrating expression pedals A and B 12 3 APPLICATIONS 13 3 1 Basic setup eg 13 3 2 Expanded setup using the switch function 13 3 3 Connections general eneneneennennenne 13 4 MIDI A STANDARD A REVOLUTION 00 14 4 1 MIDI COMME CONS samesenca eum avec eee 14 4 2 MIDI data format nenene 4 2 1 NOTE ON and NOTE OFF messages 4 2 2 CONTROL CHANGE messages 14 4 2 3 PROGRAM CHANGE messages 14 4 2 4 Running status 0 0 eee eeeeeeenteeees 15 5 MIDI IMPLEMENTATION secceeeseeeesseeeeeeeeeees 15 6 SPECIFICATIONS ccesseeceseeceeseeeeeeseeeeseeeeneneeeees 15 7 WARRANTY 2 22 2222 22er 16 MIDI FOOT CONTROLLER FCB1010 1 INTRODUCTION Congratulations With the BEHRINGER MIDI FOOT CONTROLLER FCB1010 you purchased an ultra flexible controller unit for a wide range of applications whether you are a guitarist keyboard player or studio engineer 10 BANKS with 10 PRESETS each and two fully user programmable expression pedals will give you enough flexibility to manage your MIDI eq
13. FCB1010 MIDI FOOT CONTROLLER User s Manual x w O Z m Version 1 4 March 2003 753710109 BEHRINGER www behringer com JUST LISTEN MIDI FOOT CONTROLLER FCB1010 IMPORTANT SAFETY INSTRUCTIONS CAUTION WARNING A CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN ATTENTION RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR A To reduce the risk of electric shock do not remove the top cover or the rear section No user serviceable parts inside refer servicing to qualified personnel To reduce the risk of fire or electric shock do not expose this appliance to rain and moisture This symbol wherever it appears alerts you to the presence of uninsulated dangerous voltage inside the enclosure voltage that may be sufficient to constitute a risk of shock This symbol wherever it appears alerts you to important operating and maintenance instructions in the accompanying literature Please read the manual DETAILED SAFETY INSTRUCTIONS 1 Read these instructions 2 Keep these instructions 3 Heed all warnings 4 Follow all instructions 5 Do not use this device near water 6 Clean only with a dry cloth 7 Do not block any ventilation openings Install in accordance with the manufacturer s instructions 8 Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defea
14. ONFIG These LEDs are on in the default setting and indicate that programmed connection state is kept Basically CONFIGURATION mode functions are active as long as the corresponding footswitch LED is lit 2 3 Quick start guide for PRESET programming ef eae UP UP sr fs hr DOWN SWITCH Fig 2 4 PRESET programming For each of the 100 PRESETS you can determine which MIDI functions shall be transmitted as soon as you select the respective PRESET For instance you can send five different A A Select the PRESET you wish to edit Press DOWN for more than 2 5 sec to enter PRESET programming mode The number in the display disappears while the green SWITCH 1 SWITCH2 LED in the display starts flashing Use footswitches 1 and 2 to edit the status of the SWITCHES The current status is indicated by the foot switch LED and the corresponding SWITCH LED in the acrylic display For further details see chapter 3 3 Connections general Please note that the status of the SWITCHES can also be toggled with UP SWITCH 1 and DOWN SWITCH 2 if DIRECT SELECT is enabled The only prerequisite is that this function has been enabled for both SWITCHES in the CONFIGURATION menu Confirm with UP ENTER The SELECT LED in the display lights up Activate individual MIDI functions by keeping the respective footswitch depressed for roughly 1 5 sec Footswitch LEDs indicate the activated footswitches of the respective MIDI functions A
15. ROGRAM CHANGE messages PROGRAM CHANGE messages are used to change presets or sounds in connected devices instruments The parameter range is 0 through 127 The values 0 to 127 of the 128 presets are available Equipment with more than 128 presets has these presets broken down into several banks for MIDI control With your FCB1010 it is possible to send MIDI bank and program change commands by using just one keystroke An external piece of equipment e g effects processor sound module etc can be controlled via controllers 1 amp 3 in connection with PRG 5 PROG CHG In doing so controllers 1 amp 2 are used as 2 byte bank select controllers whereby up to 128 MSB x 128 LSB banks can be dialed in Controller 1 needs to contain the number 00 and the MSB bank value while controller 2 needs to contain the number 32 and the LSB bank value The program change command that activates the preset in the new bank is sent with PRG 5 Almost all devices have a list enclosed which shows the program change number versus preset number assignment Some units even allow you to freely assign program change commands to preset numbers Please see the corresponding user s manual for detailed information 14 4 MIDI A STANDARD A REVOLUTION MIDI FOOT CONTROLLER FCB1010 6 SPECIFICATIONS 4 2 4 Running status Since the MIDI standard uses a serial transmission format i e transmits data successively it was soon found that the transmissi
16. T is enabled Determines if DOWN key toggles 2 SWITCH 2 SWITCH 2 relay while DIRECT SELECT is enabled Zar Enables copying presets see ch PRESET 2 4 1 SYSEX Sends the entire memory as a sysex ee When this switch is ry the SYSEX FCB1010 waits for the reception of 7 RCV system exclusive data Switch LED dies out when the data have been received correctly Allows to merge MIDI IN data with FCB1010 generated data The MERGE combined data stream is subsequently output at the MIDI OUT Enables disables running status feature Serves to make efficient use RUNNING of the MIDI transmission rate The STATUS MIDI status byte from the expression pedals is sent only if it differs from the preceding status byte Tab 2 2 Assignment of footswitches in CONFIGURATION setup menu I External equipment for example guitar or bass amps can be controlled by using SWITCH 1 and 2 outputs of the FCB1010 If the FCB1010 triggers this function you should first check if the piece of equipment you are trying to control reacts to connection state contact open or closed or current feed contact closed as long as the switch is depressed BEHRINGER guitar and bass amps react to current feeds Therefore when you wish to remotely control channel change on a BEHRINGER guitar amp not via MIDI but via switch outputs because you have no MIDI cable at your disposal you have to power off switch 1 amp 2 LEDs in GLOBAL CONFIGURATION menu under C
17. The displays reads 09 to 00 and the points are blinking When the points are no longer shown your FCB1010 has been reset to factory defaults and is ready for operation 2 9 Calibrating expression pedals A and B Should you experience problems with exact MIDI controller data transmission while using the expression pedals we recommend calibrating the pedals Calibrating the pedals follows the complition of the FCB1010 self test I amp All software versions 1 4 and newer allow for direct calibration by keeping the switches 1 and 5 pressed while powering up the unit If your FCB1010 features the software version 1 4 or higher skip the first 4 steps in the set of instructions that follow i e start at point number 5 To find if your unit features version 1 4 or higher of the software first try keeping the switches 1 and 5 pressed while powering up the unit If nothing happens start calibrating your FCB1010 beginning with the first step in the list that follows 2 PROGRAMMING THE FCB1010 MIDI FOOT CONTROLLER FCB1010 A Keep the switches 1 and 3 pressed while powering up the unit This puts your FCB1010 into self test mode and all LEDs are being tested A Please wait until all switch LEDs light up Then press all the switches including the UP ENTER and DOWN ESCAPE keys so that all LEDs are turned off A Wait for a moment while the relay test is completed four quiet cliking sounds are heard The display shows F1 if
18. annels instead your entire setup is centrally controlled from the FCB1010 3 3 Connections general Please use commercial grade cables with phone plugs to connect the SWITCH outputs of your FCB1010 to your amplifier Since these outputs are normalized you can send both switching pulses from one SWITCH output by using a stereo cable which is useful in combination with amplifiers that have a stereo phone jack to select several functions e g channel select and effect on off In this case please use only one of the two SWITCH outputs with one stereo cable connected 13 Find out whether or not your guitar amp supports a stereo connection via SWITCH 1 or SWITCH 2 Simply try and experiment to identify the switching configuration of your amp 3 APPLICATIONS 13 MIDI FOOT CONTROLLER FCB1010 4 MIDI A STANDARD A REVOLUTION In the early 80 s several leading manufacturers of electronic musical instruments developed a common standard which was soon to revolutionize the entire MI industry both from a technical and musical point of view The MIDI standard short for Musical Instruments Digital Interface was invented to allow musical instruments of different makes to communicate with each other What is surprising in view of the rapidly developing MI industry is the fact that this standard has basically not changed ever since because it was designed with future upgrades in mind So the MIDI interface s range of applications
19. could be expanded over the years from the simple connection of several keyboard instruments to one master keyboard to connecting whole studios and live set ups within a single MIDI network MIDI has become an infinite source of ideas and innovation Numerous musicians recognized the versatility of this standard and created new and exciting worlds of sounds by combining different instruments to one homogeneous whole It is important to know that the MIDI interface transmits no audio signals but only control data e g key program change or volume numbers MIDI is just an interface for the control and networking of devices and instruments At the heart of this network you could use your FCB1010 to control all of your amplifiers effects and peripheral devices Live on stage and in the studio you could control your entire equipment in real time MIDI control data can be stored and edited on a computer so that you can also use your FCB1010 to enter controller and program change information into your computer 4 1 MIDI connections The MIDI connectors on the rear of the unit are on internationally standardized 5 pin DIN jacks To connect your FCB1010 to other MIDI devices you need a dedicated MIDI cable Usually commercially available cables are used However you can also use a two conductor shielded cable e g microphone cable and two rugged 180 DIN plugs to make your own MIDI cable pin 2 center shield pins 4 and 5 right and left o
20. f designing our new FCB1010 certainly meant a great deal of responsibility which we assumed by focusing on you the discerning user and musician Meeting your expectations also meant a lot of work and night shifts But it was fun too Developing a product usually brings a lot of people together and what a great feeling it is when all who participated in such a project can be proud of what they ve achieved It is our philosophy to share our enjoyment with you because you are the most important member of the BEHRINGER team With your highly competent suggestions for new products you ve made a significant contribution to shaping our company and making it successful In return we guarantee you uncompromising quality as well as excellent technical and audio properties at an extremely reasonable price All of this will enable you to give free rein to your creativity without being hampered by budget constraints We are often asked how we manage to produce such high quality devices at such unbelievably low prices The answer is quite simple it s you our customers Many satisfied customers mean large sales volumes enabling us to get better purchasing terms for components etc Isn t it only fair to pass this benefit on to you Because we know that your success is our success too would like to thank all of you who have made the FCB1010 possible You have all made your own personal contributions from the developers to the many other empl
21. f pin 2 internal conductor pins 1 und 3 the two outer pins are not used MIDI cables should not be longer than 15 meters MIDI IN serves to receive recorded system exclusive data or to merge any MIDI signals with FCB1010 generated data I amp S The FCB1010 has no dedicated MIDI THRU port However the data received at the MIDI IN can be routed to the MIDI OUT provided that the MERGE function is enabled GLOBAL CONFIGURATION MIDI OUT The MIDI OUT allows you to transmit data to any MIDI compatible device instrument 4 2 MIDI data format Although the FCB1010 is very easy to operate it does make sense to know a few things about the format of MIDI data Each MIDI command or message consists of up to three bytes 1 byte 8 bits There s a difference between status bytes and data bytes status bytes define the type of a specific MIDI message i e the actual instruction to be sent to a device while data bytes contain the information or parameters defined by the corresponding status byte One status byte can be followed by up to two data bytes There are various types of MIDI messages Since the FCB1010 does not understand or transmit all of them we will only deal with those that are of importance to you in this context 4 2 1 NOTE ON and NOTE OFF messages NOTE ON and NOTE OFF messages are essential MIDI messages for any keyboard virtuoso as they allow to control remote instruments from one master keyboard or computer The
22. ff setting when you connect the FCB1010 to the mains Attention The POWER switch does not physically disconnect the unit from the mains Always unplug the unit from the mains when you do not plan on using it for prolonged periods of time SERIAL NUMBER Please take the time to have the warranty card filled out completely and return it within 14 days after the date of purchase so as to be entitled to benefit from our extended warranty Or use our online registration option available on the World Wide Web under www behringer com CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL CAUTION TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE SWITCH 2 MIDI OUT THRU Mm 12 12 13 Fig 1 3 Rear panel connectors SWITCH 1 and 2 Use these jacks to connect your amplifier for channel selection mono or stereo phone jack cable MIDI IN The MIDI IN of your FCB1010 connects to a sequencer or similar device in order to download the memory data saved before with the help of the MIDI SysEx function Additionally data can be looped through the FCB1010 and merged with other data using the MIDI MERGE function Subsequently the combined data are available at the MIDI OUT THRU connector MIDI OUT THRU Use this jack to connect the devices you wish to contr
23. g studio equipment guitar equipment etc If you wish to save your data on an external sequencer computer please follow the instructions below A Connect the MIDI OUT of your FCB1010 to the MIDI IN of your sequencer computer see fig 2 5 A Keep the DOWN switch pressed roughly 2 5 sec during power up to enter the GLOBAL CONFIGURATION menu A Press UP until the CONFIGURATION LED lights up Now the unit is in CONFIGURATION mode A Start the RECORD function on your sequencer computer The footswitch LED lights up and is no longer lit up when all SysEx data from the FCB1010 have been transmitted Then press footswitch 6 to dump the FCB1010 data Quit the GLOBAL CONFIGURATION menu by means of a long press on DOWN ESCAPE 2 PROGRAMMING THE FCB1010 11 MIDI FOOT CONTROLLER FCB1010 MIDI SEQUENZER Midi In OO Midi Out rem MIDI FOOT CONTROLLER FCB1010 To send back FCB1010 data stored on a sequencer computer Fig 2 5 Sending a SysEx Dump 2 7 2 Receiving SysEx dumps before please follow the instructions below A 12 Connect the MIDI OUT connector of your sequencer or computer to the MIDI IN connector of the FCB1010 see fig 2 6 Keep the DOWN switch pressed during power up to enter the GLOBAL CONFIGURATION menu Press UP until the CONFIGURATION LED lights up N
24. h the delay time can be programmed The higher the value the higher the resolution A Confirm your entry with UP ENTER The SELECT LED lights up A Disable Control Change 1 CNT 1 by means of a long foot switch press on footswitch 6 This is necessary because otherwise each time you select the PRESET used for tempo tapping the FCB1010 would transmit the controller defined here including the adjusted VALUE parameter instead of the FCB1010 generated value A Quit PRESET programming mode by means of a long press on DOWN Now the TAP TEMPO function is ready for use To use the tap tempo feature press the footswitch which selects the PRESET just programmed twice in the rhythm of the music e g every crotchet or quaver note The FCB1010 will calculate the delay time and send it to the receiving device by means of the controller you selected before If the interval between the two footswitch presses is greater than the maximum NOTE NUMBER value the FCB1010 will divide the time by 2 until it is equal to or smaller than the maximum value Thus a crotchet delay becomes a quaver or semiquaver delay depending on which value can be processed in the receiving device 2 7 Data storage 2 7 1 Saving the FCB1010 memory with the help of SysEx dumps The FCB1010 allows you to transmit PRESETS in the form of system exclusive data to a sequencer or other MIDI recorder In this way you can save your data or manage several MIDI set ups e
25. ill be sent each time you select the PRESET Getting your foot off the switch transmits the NOTE OFF command IS To tap the tempo simply press the PRESET switch several times in the rhythm of the music 13 CNT 1 is always transmitted together with the note on command For example it can be used for sending a volume value number 07 together with a note to trigger a sound When the controller s operation is not desired it can either be relayed to an unused MIDI channel in GLOBAL CONFIGURATION this channel is then valid for all presets or an unused controller number can be assigned to the controller can be done for each individual preset 10 2 PROGRAMMING THE FCB1010 MIDI FOOT CONTROLLER FCB1010 2 5 Controller toggle function This function allows you to configure one controller so that it alternately sends two different values e g effect bypass drive on off etc A In order to enable the controller switch over function you need to globally select the same MIDI channel for CNT1 and CNT2 see chapter 2 2 and enter the same controller number for CNT1 and CNT2 in the preset NUMBER see chapter 2 4 4 The first time you recall the preset it will send the controller value of CNT1 VALUE 1 with each additional key press you can alternate between CNT2 and CNT1 Example Select preset 1 without DRIVE function on the BEHRINGER V AMP each time you press the same button again DRIVE will be switched on or off res
26. lay lights up You can use the UP and DOWN keys to navigate through GLOBAL CONFIGURATION main pages Pressing UP leafs through the pages forward pressing DOWN leafs the pages backward A corresponding LED indicates what page you are on GLOBAL SELECT CONFIGURATION MIDI CHANNEL UP DOWN SELECT MIDI FUNCTION DOWN UP DOWN DIRECT SELECT DOWN GLOBAL SETUP Fig 2 3 GLOBAL CONFIGURATION menu structure To leave GLOBAL CONFIGURATION menu you need to press the DOWN ESCAPE key for at least 2 5 sec I amp Only keeping the DOWN ESCAPE key pressed for at least 2 5 sec saves your newly entered settings 2 2 1 DIRECT SELECT page Keep the DOWN ESCAPE key pressed while you power up the unit This takes you to the GLOBAL CONFIGURATION menu the green DIRECT SELECT LED lights up To activate DIRECT SELECT press 10 0 key The red LED lights up Now you have 2 PROGRAMMING THE FCB1010 to confirm activating DIRECT SELECT to be able to directly select presets To do this keep DOWN ESCAPE pressed for 2 5 sec to exit GLOBAL CONFIGURATION The display now shows 00 Now you can directly select the presets as described in ch 2 1 2 2 2 2 MIDI channel setting To get from DIRECT SELECT to MIDI FUNCTION press UP The MIDI FUNCTION LED flashes correspondingly This is where you determine the MIDI channels that can be sent from the FCB1010 for various MIDI functions You can assign different MIDI channels to MIDI functions For
27. n pedal A A Confirm your selection with UP ENTER The VALUE 2 LED lights up A Enterthe value to be transmitted when the pedal is completely pressed downward by using the foot keys or the expression pedal A 13 Use DOWNI ESCAPE to go one step backward gt Confirm your selection with UP ENTER The SELECT LED lights up A Quit PRESET programming mode by means of a long press on DOWN or select another MIDI function for editing 2 4 6 Programming the NOTE function The NOTE function allows you to send a MIDI note for example to use the tap tempo features offered by many MIDI devices or to play sounds the same way you would on a keyboard A Select the PRESET you wish to edit A Keep DOWN pressed for more than 2 5 sec to enter PRESET programming mode The green SWITCH 1 SWITCH 2 LED in the display starts flashing A Use UP ENTER to get to the next page The SELECT LED in the display begins to light up I To program a MIDI function you have to first activate it Individual MIDI functions are activated by keeping the corresponding keys pressed for a few seconds Active MIDI functions are indicated by a permanently lit footswitch LED A Keep footswitch 10 0 pressed for a few seconds to activate the NOTE function Pressing the footswitch briefly once again makes the footswitch LED blink A Confirm your selection with UP ENTER The NUMBER LED lights up A Use the footswitches 1 through 10 0 or EXPRESSION PEDAL A to e
28. nter the MIDI NOTE number you wish to send with the PRESET You can choose from the values 0 through 127 The table below shows which musical notes are assigned to which MIDI notes with a detailed list for the octave from C 2 to C 1 simply use this pattern to assign the remaining notes octaves yourself Musical Note MIDI Note Number ee c ode2 tf D 2 D 2 Eb 2 E 2 F 2 F 2 Gb 2 G 2 G 2 Ab 2 A 2 A 2 Bb 2 H 2 11 C 1 12 24 36 48 60 Yamaha Convention C3 Clef C Tab 2 4 Assignment of MIDI NOTE numbers A Confirm your selection by pressing UP ENTER or cancel by pressing DOWN ESCAPE The SELECT LED in the display lights up A Select an additional MIDI function you wish to edit or exit the PRESET programming mode by keeping DOWN ESCAPE pressed for a few seconds The NOTE function will be particularly useful for so called tap tempo applications Many of today s multi effects devices allow the user to enter the delay time by means of an on board TAP button The device measures the time between two TAP button presses and uses this interval to adjust the delay time Often this function can be remotely controlled via MIDI In this case tapping is the transmission of two subsequent NOTE ON commands which is what the NOTE function of your FCB1010 does for you For example this is how a sequencing software can be launched or closed I If you program the NOTE function with a PRESET a NOTE ON command w
29. ol from your FCB1010 The SOFT THRU circuit allows you to loop through any signals present at the MIDI IN of your FCB1010 merge them with the unit s own data stream and finally output the combined data at the MIDI OUT 2 PROGRAMMING THE FCB1010 In this chapter you will learn to program your FCB1010 and adapt it to your specific MIDI set up But don t worry you won t have to learn a programming language before you could give your FCB1010 a single MIDI command The unit will perform all functions for you one after the other Simply make and confirm your choices If particular functions prompt you to enter a parameter this will be covered specifically 2 1 Selecting BANKS and PRESETS There are two options to select a BANK and the PRESETS it contains Which one you use depends on the DIRECT SELECT parameter in the GLOBAL CONFIGURATION menu If DIRECT SELECT is on you can use the PRESET footswitches to directly select the BANK number followed by the PRESET number If DIRECT SELECT is off you need to step through the various BANKS using the UP DOWN switches then select a PRESET from a bank The default setting is OFF The illustrations below show the two options 2 1 1 DIRECT SELECT deactivated Let s assume you wish to select PRESET 1 from BANK 3 Step 1 Use the UP DOWN switches to go to the BANK that contains the PRESET of your choice here BANK 3 Step 2 Select the PRESET you wish to use here PRESET 1
30. omized for BEHRINGER amplifiers V AMP 2 and BASS V AMP Two expression pedals with freely assignable MIDI channel controller number and range Simultaneous transmission of five MIDI program change commands and two MIDI controllers per preset MIDI NOTE commands for trigger and tap tempo applications Two programmable relais controlled SWITCH jacks e g to select channels on any guitar amp Enhanced ergonomic design No need to take a seat everything can be easily programmed while standing up Global Configuration allows for individual customization MIDI SysEx backup function MIDI MERGE function allows for SOFT THRU and merging of controller and input data Built in power supply ensures trouble free operation Open architecture for future software upgrades Extremely rugged construction ensures long life even under the most demanding conditions Manufactured under ISO9000 certified management system MIDI FOOT CONTROLLER FCB1010 FOREWORD Dear Customer welcome to the team of BEHRINGER users and thank you very much for expressing your confi dence in us by pur chasing the FCB1010 Writing this foreword for you gives me great pleasure because it represents the cul mination of many months of hard work delivered by our engineering team to achieve a very ambitious goal to present you with an outstanding device that gives you maximum flexibility and perfor mance both live on stage and in the studio The task o
31. on rate is too low if the system is exploited to its full capacity To make up for an audibly delayed transmission of MIDI data the so called running status was introduced which suppresses the status byte in two or more identical MIDI messages that follow each other For example if the data bytes of a controller e g volume are changed continuously the corresponding status byte is sent only once Only the data byte changes are transmitted as long as another status byte is sent i e in each message transmitted you can eliminate 8 bits This is also the reason why NOTE OFF messages are no longer used When a keyboard player plays a scale on a keyboard and sends these data via MIDI to a computer each NOTE ON message would be followed by a NOTE OFF message each time a key is released The running status would identify the NOTE OFF message as a new status byte and hence send it which results in a data amount of 8 notes times 8 bits i e 192 bits Since NOTE ON messages belong to those MIDI messages that are used most often it was decided to send NOTE ON messages with zero velocity instead The audible effect is the same but in the Running Status the data amount can be reduced by 7 times 8 bits i e 56 bits As a consequence the overall data amount produced by the scale mentioned above is only 136 bits With the FCB1010 you are free to switch the Running Status feature on or off see ch 2 2 3 5 MIDI IMPLEMENTATION MIDI Implementation
32. ow the unit is in CONFIGURATION mode Press footswitch 7 SYSEX RCV to tell the FCB1010 to wait for system exclusive data the footswitch LED lights up Start the PLAYBACK function on your sequencer computer to play back the previously stored file The foot switch LED flashes while the FCB1010 is receiving data Once the data have been received correctly the LED dies out Now your programs are back in the FCB1010 s memory Quit GLOBAL CONFIGURATION mode by means of a long press on DOWN MIDI SEQUENZER a Midi Out OO Midi In MIDI FOOT CONTROLLER FCB1010 Fig 2 6 Receiving a SysEx dump 2 8 Restoring factory presets This function allows you to restore factory defaults of your FCB1010 13 In doing so all preset settings made by you are overwritten Resetting your FCB1010 lets you restore various default settings that are optimized for use with BEHRINGER audio equipment This is why there are three different key combinations that let you reload the desired defaults into the memory of your FCB1010 This key combinations are shown in table 2 5 Switch Default setting for V AMP family products BEHRINGER guitar amps BASS V AMP product range Tab 2 5 Reset key combinations Keep the respective footswitches pressed for roughly 2 5 sec while powering up your FCB1010
33. oyees at this company and to you the BEHRINGER user My friends it s been worth the effort Thank you very much Uli Behringer TABLE OF CONTENTS 1 INTRODUCTION uuzuessunsunennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 5 1 1 Before you get started 1 1 1 Shipment 1 1 2 Initial operation 1 1 3 W rranty nen 2 The user s manual meemeeenmennnnn 3 Control elements 1 3 1 Frontpa el cesia 22a sera 1 3 2 Rear panel ao 2 PROGRAMMING THE FCB1010 22u0442244444Bn nn 6 2 1 Selecting BANKS and PRESETS een 6 2 1 1 DIRECT SELECT deactivated 6 2 1 2 DIRECT SELECT activated o oo 6 2 2 GLOBAL CONFIGURATION eceeceereeseeteeteesreneetes 7 2 2 1 DIRECT SELECT page 2 222 nennen T 2 2 2 MIDI channel setting nenne 7 2 2 3 CONFIG Page aee oeeo ee 7 2 3 Quick start guide for PRESET programming 8 2 4 Detailed PRESET programming n nee 9 2 4 1 Preset copy function eesseseessnsnensnnnnnnnnnn 9 2 4 2 Programming switches ennenne 9 2 4 3 Programming program changes 9 2 4 4 Programming CONTROL CHANGES 9 2 4 5 Programming EXPRESSION PEDALSAB 9 2 4 6 Programming the NOTE function 10 2 5 Controller toggle function
34. pectively PROG CHG 1 1 CNT 1 NUMBER 26 VALUE 1 0 CNT 2 NUMBER 26 VALUE 1 127 2 6 TAP TEMPO function In addition to the NOTE function which is used by many effects devices to tap the song tempo the FCB1010 offers you another way to reach this goal the TAP TEMPO function also allows you to enter the song tempo however transmits a FCB1010 generated controller value to the controlled effects device in order to adjust the delay time Advantage you can also control devices that cannot process NOTE commands but only allow for changing the delay time by means of a MIDI controller I The TAP TEMPO function does not work with DIRECT SELECT enabled The TAP TEMPO function has no dedicated switch but is activated as follows A Select the PRESET you wish to edit A Keep the DOWN ESCAPE key pressed longer than 2 5 sec to get to the programming mode The green SWITCH 1 SWITCH 2 LED in the display starts flashing A Use the UP ENTER key to get to the next page The SELECT LED in the display is lit Ik gt To program a MIDI function you have to first activate it Individual MIDI functions are activated by keeping the corresponding keys pressed for a few seconds Active MIDI functions are indicated by a permanently lit footswitch LED A Select the NOTE function you wish to edit by keeping the 10 0 key pressed for a few seconds and then consequently tap it once again briefly The footswitch LED blinks A Confirm
35. permission of BEHRINGER Spezielle Studiotechnik GmbH BEHRINGER BLUE DEVIL VIRTUALIZER and V AMP are registered trademarks ALL RIGHTS RESERVED 2003 BEHRINGER Spezielle Studiotechnik GmbH BEHRINGER Spezielle Studiotechnik GmbH Hanns Martin Schleyer Str 36 38 47877 Willich M nchheide Il Germany Tel 49 0 21 54 92 06 0 Fax 49 0 21 54 92 06 30 16 7 WARRANTY
36. reight prepaid 3 Warranty claims other than those indicated above are expressly excluded 3 RETURN AUTHORIZATION NUMBER 1 To obtain warranty service the buyer or his authorized dealer must call BEHRINGER see enclosed list during normal business hours BEFORE returning the product All inquiries must be accompanied by a description of the problem BEHRINGER will then issue a return authorization number 2 Subsequently the product must be returned in its original shipping carton together with the return authorization number to the address indicated by BEHRINGER 3 Shipments without freight prepaid will not be accepted 4WARRANTY REGULATIONS 1 Warranty services will be furnished only if the product is accompanied by a copy of the original retail dealer s invoice Any product deemed eligible for repair or replacement by BEHRINGER under the terms of this warranty will be repaired or replaced within 30 days of receipt of the product at BEHRINGER 2 If the product needs to be modified or adapted in order to comply with applicable technical or safety standards on a national or local level in any country which is not the country for which the product was originally developed and manufactured this modification adaptation shall not be considered a defect in materials or workmanship The warranty does not cover any such modification adaptation irrespective of whether it was carried out properly or not Under the terms of thi
37. s long as the display indicates SELECT you can activate MIDI functions and select them for editing by briefly pressing the corresponding footswitch The selected footswitch LED and the display blink during selection and activation The NUMBER LED is also lit The following MIDI functions are available for selection Switch MIDI function Action Tab 2 3 Footswitch assignment in PRESET programming mode I MIDI channel adjustment for the respective MIDI functions is not done during preset programming it is done in GLOBAL CONFIGURATION on MIDI FUNCTION page see ch 2 2 2 Confirm your selection with UP ENTER in order to start programming the selected MIDI function or cancel with DOWN ESCAPE Use footswitches 1 through 10 0 or EXPRESSION PEDAL A to enter the parameter values of your choice If you have selected PROGRAM CHANGE as the MIDI function to be edited you can now enter a program change number from 1 through 128 and confirm your selection with UP ENTER If you have selected CNT1 or CNT2 you can now enter the number of the controller to be sent 0 through 127 when you press the corresponding footswitch After confirming your selection with UP ENTER you can select a controller value 0 through 127 Confirm your selection with UP ENTER 8 2 PROGRAMMING THE FCB1010 MIDI FOOT CONTROLLER FCB1010 Ik gt To program a MIDI function you have to first activate If you have selected EXP A or EXP B you can now enter
38. s warranty BEHRINGER shall not be held responsible for any cost resulting from such a modification adaptation 3 Free inspections and maintenance repair work are expressly excluded from this warranty in particular if caused by improper handling of the product by the user This also applies to defects caused by normal wear and tear in particular of faders potentiometers keys buttons and similar parts 4 Damages defects caused by the following conditions are not covered by this warranty A improper handling neglect or failure to operate the unit in compliance with the instructions given in BEHRINGER user or service manuals A connection or operation of the unit in any way that does not comply with the technical or safety regulations applicable in the country where the product is used A damages defects caused by force majeure or any other condition that is beyond the control of BEHRINGER 5 Any repair or opening of the unit carried out by unauthorized personnel user included will void the warranty 6 If an inspection of the product by BEHRINGER shows that the defect in question is not covered by the warranty the inspection costs are payable by the customer 7 Products which do not meet the terms of this warranty will be repaired exclusively at the buyer s expense BEHRINGER will inform the buyer of any such circumstance If the buyer fails to submit a written repair order within 6 weeks after notification BEHRINGER
39. ssing UP ENTER The NUMBER LED in the display lights up Enter the program change command 1 bis 128 via the footswitch or expression pedal A Confirm your selection by pressing UP ENTER or cancel by pressing DOWN ESCAPE The SELECT LED in the display lights up Select an additional MIDI function you wish to edit or exit the PRESET programming mode by keeping the DOWN ESCAPE key for a few seconds 2 4 4 Programming CONTROL CHANGES Select the PRESET you wish to edit Keep DOWN pressed for more than 2 5 sec to enter PRESET programming mode The green SWITCH 1 SWITCH 2 LED in the display starts flashing Use the UP ENTER key to get to the next page The SELECT LED in the display lights up To program a MIDI function you have to first activate it Individual MIDI functions are activated by keeping the corresponding keys pressed for a few seconds Active MIDI functions are indicated by a permanently lit footswitch LED Keep the corresponding footswitch foot key 6 or 7 pressed for a few seconds to activate the controller you wish to edit The controller is selected by pressing the key briefly again The LED blinks Confirm your selection by pressing UP ENTER The NUMBER LED in the display lights up Enter the desired controller number 0 to 127 by using the foot keys or the expression pedal A Confirm your selection with UP ENTER The VALUE 1 LED in the display lights up Use the footswitches 1 through 10 0 or EXPRESSION
40. t the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs extension cords and the point at which they exit the unit 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the device When a cart is used use caution when moving the cart device combination to avoid injury from stumbling over it LI _ 13 Unplug this device during lightning storms or when not used for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the unit has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the device the unit has been exposed to rain or moisture does not operate normally or has been dropped MIDI FOOT CONTROLLER FCB1010 MIDI FOOT CONTROLLER Ultra Flexible MIDI FOOT CONTROLLER with Two Expression Pedals and MIDI Merge Function A 10 banks of presets each with 10 fully user editable presets cust
41. ter your product may void future warranty claims 1 2 The user s manual The user s manual is designed to give you both an overview of the control elements as well as detailed information on how to use them In order to help you understand the links between the controls we have arranged them in groups according to their function If you need to know more about specific issues please visit our website at www behringer com where you ll find additional information on mixing consoles effects units and dynamic processors 1 3 Control elements 1 3 1 Front panel eee E lilalila i Fig 1 1 Front panel control elements FOOTSWITCHES 1 through 10 0 These keys are used for changing the presets programming entering values in programming mode and activating the DIRECT SELECT function 10 0 only 2 UP DOWN keys These keys are used to navigate through different banks and programming layers When in programming mode use the UP key for ENTER confirm and the DOWN key for ESCAPE cancel IS When DIRECT SELECT mode is activated see chapter 2 PROGRAMMING THE FCB1010 the UP DOWN switches are no longer needed for BANK selection and are free to perform a special function in the GLOBAL CONFIGURATION menu you can program them to control the SWITCH RELAYS UP SWITCH 1 RELAY DOWN SWITCH 2 RELAY In this case you can
42. the controller number the EXPRESSION PEDAL of your choice is aimed to send values for Confirm your selection with UP ENTER and enter the lower value pedal up Confirm with UP ENTER Afterwards enter the upper value pedal pressed down completely and confirm once again with UP ENTER Please keep in mind that the first controller value always has to be lower than the second controller value You can quit the programming mode at any time by means of a long press on DOWN Any confirmed entries will be stored with the currently selected PRESET How to program the NOTE function is explained in chapter 2 4 6 2 4 Detailed PRESET programming 2 4 1 Preset copy function The preset copy function copies an already programmed preset to a new preset of your choice This saves you time since you do not have to repeat all adjustments for each newly programmed preset A Activate CONFIG in the GLOBAL CONFIGURATION see chapter 2 2 A Now press footswitch 5 to activate the copy function The VALUE 1 LED lights up The number in the display and the footswitch LED start flashing A Enter the number of the preset you wish to copy and confirm your selection with UP ENTER The VALUE 2 LED lights up The number in the display and the footswitch LED start flashing I gt Presets 1 10 are stored in bank 0 presets 11 20 in bank 1 and so on A Enter the target preset and confirm your selection with UP ENTER or cancel with DOWN ESCAPE
43. the risk of overheating Ik gt Before plugging the unit into a power socket please make sure you have selected the correct voltage The fuse compartment near the power plug socket contains three triangular markings Two of these triangles are opposite one another The voltage indicated adjacent to these markings is the voltage to which your unit has been set up and can be altered by rotating the fuse compartment by 180 ATTENTION This does not apply to export models that were for example manufactured only for use with 120 V I gt If you alter the units voltage you must change the fuse accordingly The correct value of the fuse needed can be found in the chapter SPECIFICATIONS Ik gt Faulty fuses must be replaced with fuses of appropriate rating without exception The correct value of the fuses needed can be found in the chapter SPECIFICATIONS Power is delivered via the cable enclosed with the unit All requiered safety precautions have been adhered to 13 Please make sure that the unit is grounded at all times For your own protection you should never tamper with the grounding of the cable or the unit itself 1 INTRODUCTION 1 1 3 Warranty Please take a few minutes and send us the completely filled out warranty card within 14 days of the date of purchase You may also register online at www behringer com The serial number needed for the registration is located at the top of the unit Failure to regis
44. uipment Guitar players will particularly appreciate the option of selecting channels using two analog SWITCHES as they allow you to fully control both amplifier and effects from one switching center And with its ultra rugged enclosure and built in power supply the FCB1010 is absolutely ready for the road too The easy to use programming interface gives you fun instead of frustration and invites you to fully exploit the capabilities of your MIDI equipment Ik gt The following user s manual is intended to familiarize you with the unit s control elements so that you can master all the functions After having thoroughly read the user s manual store it at a safe place for future reference 1 1 Before you get started 1 1 1 Shipment The FCB1010 was carefully packed at the factory to assure secure transport Should the condition of the cardboard box suggest that damage may have taken place please inspect the unit immediately and look for physical indications of damage I amp S Damaged units should NEVER be sent directly to us Please inform the dealer from whom you acquired the unit immediately as well as the transportation company from which you took delivery of the unit Otherwise all claims for replacement repair may be rendered invalid 1 1 2 Initial operation Please make sure the unit is provided with sufficient ventilation and never place the FCB1010 on top of an amplifier or in the vicinity of a heater to avoid
45. will return the unit C O D with a separate invoice for freight and packing Such costs will also be invoiced separately when the buyer has sent in a written repair order 5 WARRANTY TRANSFERABILITY This warranty is extended exclusively to the original buyer customer of retail dealer and is not transferable to anyone who may subsequently purchase this product No other person retail dealer etc shall be entitled to give any warranty promise on behalf of BEHRINGER 6 CLAIM FOR DAMAGES Failure of BEHRINGER to provide proper warranty service shall not entitle the buyer to claim consequential damages In no event shall the liability of BEHRINGER exceed the invoiced value of the product 7 OTHER WARRANTY RIGHTS AND NATIONAL LAW 1 This warranty does not exclude or limit the buyer s statutory rights provided by national law in particular any such rights against the seller that arise from a legally effective purchase contract 2 The warranty regulations mentioned herein are applicable unless they constitute an infringement of national warranty law Customers in the European Union please contact BEHRINGER Germany Support for further details The information contained in this manual is subject to change without notice No part of this manual may be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying and recording of any kind for any purpose without the express written
Download Pdf Manuals
Related Search
Related Contents
Samsung MAX-VJ550 User Manual ICOM4009 - Asignación No. 2 取付説明書(PDF) Manual en formato PDF Cisco 1861E IRWIN 10507860 hand saw AZUMI Flute.indd 取扱説明書 - セイコークロック Battery BacPac™ Copyright © All rights reserved.
Failed to retrieve file