Home
M3 Manual Dispenser User`s Manual
Contents
1. 7 3 Periodical Maintenance Santint M3 Manual Dispenser V1 0 7 The dispenser must be maintained every 3 6 months 01 Check to see if the fixed base is loose or not Figure 7 3 1 If loose push the base to the bottom most position fasten two screws of the base Symmetrically with inner hexagon Spanner Figure 7 3 2 3 Note don t screw too hard 02 Open canister lid during the process of mixing to observe if the agitator works normally For any abnormity stop mixing and repair the canister 03 Cleaning the nozzle Rotate the valve handle and pull out the nozzle Clean the nozzle with cotton moistened with water or thinner Then rotate the valve handle once again to reinstall the nozzle Attention After reinstallation of nozzle dispense out certain amount of colorant to fill the nozzle The reinstallation must be carried out carefully The M3 by default is installed with a large size nozzle The end user can choose to install a different size nozzle according to the colorant s viscosity 7 4 Yearly Maintenance After a long period of use colorant may be stuck to the inner wall of the pump and canister This will make the piston difficult to move and cause measurement errors If this is the case cleaning must be done to canisters and pumps 01 02 03 04 05 06 07 08 09 10 11 12 Remove the canister assembly from the turntable Pour any remaining colorant from the canister i
2. 1300 1300 50X1310 mm Dimana 745X745X 745X745X 860X860X 860X860X 1016X1016X 1150X11 a 656 630 630 630 630 50X630 mm hans 51KG 53KG 63KG 65KG 72KG 85KG Floorstand Nees 42KG 44KG 54KG 56KG Countertop 5 Installation and Preparations before Operation 5 1 Installation Please refer to lt Installation Guide gt 5 2 Preparation before operation Attention Please stick the specified label on each canister to show different colorants The colorant in each canister must be fully mixed It is not recommended to be mixed by shaker as too many bubbles may appear that would cause the chromatic aberration Remove each canister lid and pour the colorant into the corresponding canister Before operation remove the air out of each pump Follow the procedures 5 2 1 step A Operation of the gauges Press and hold the Rough release button and pull the Rough gauge upwards to a certain Santint M3 Manual Dispenser V1 0 3 height ie 1Y Release the Rough release button back to its original position Lift up the plunger handle slowly to its full extent and then press it down gently Do not move the valve handle during this process Repeat the same procedures 5 6 times Follow the same procedures for the Fine gauge 5 2 2 Step B For the floor stand dispenser Operation of the shelf t rt ii ah Location Plate Groove Fi 2 2 2 Figure 5 2 2 1 Figure 5 O
3. Deae saeseiens T 1 2 General Safety Instructions RR A sees cesssnasensessbesesesosveassessves 1 3 COMPIGUPAGON Sinai nad A AA A a en ea 2 4 Major Specifications EH M 3 5 Installation and Preparations before Operation see e reen esee essen ense en enata tuse naaa tn sesta stesso seta sone ta an 3 53 Installation tee eet eR ERE eibi e ERE A tette 3 5 2 Preparation before operation sssssssssseseseeeneneenn eene eren nn enne ne innere ener 3 acute M 5 6 1 Colorant Mixing eii Ann A AA AM ener ennt ener trennt AK A AK a teens 5 6 2 Rotating and Locking of Turntable a aa alaaa Kp Aa NAMA AKA aka 5 BPA ci ee EO UE QE entunwasuecu aus QUERI RR MEE ROMAE AA AAA Ani 5 Te Mantera Uc N 7 FA Daily Mainternarnce an de cao eee ite aO Re Ee ee eese e A eee ele cote 7 7 2 Weekly Maintenance ann Ann Ma Aa Aa dena A AAA AAA AA A ia 7 7 39 Pertodical Maintenarice A A e ann AN ns A ORO A Da OR RO ptt 7 7 4 Yearly Maintenance Ann An An Ah bena ASAS A iere reete AS 8 Tox REPIACSMS iso eR OR RO a RR RR E RU tunes oni deat ms 9 7 6 Calibration RR RR e nea ee erae ede naria 9 7 7 Extended periods on MOn USGC eessesecsesccecsescececcsccecsccsccessacsccessacsccnssacaccesaasascnssasaccassasacsessasarsess 10 S Troubleshooting ss niri reete eec oct parie oti Partt s
4. M3 Manual Dispenser V1 0 6 when falling freely to the zero scale Set the Rough or Fine gauge to zero scale when it is not in use The aggregation of the shots by Rough and Fine gauges should be equal to the dispensing quantity specified in the formula 08 Use the same method to dispense all the other required colorant into the base paint can 7 Maintenance 7 1 Daily Maintenance 01 Move each plunger handle up and down three times every day to ensure smooth flow of the colorant and to avoid blockages in pumps and canisters 02 Clean the nozzle with soft cloth or cotton moistened with water or thinner to keep it unobstructed 03 Move the valve handle 5 times every day This can keep the valve in optimum working condition and prevent the colorant from drying in the valve 04 Check the colorant level in canisters and refill if necessary If the colorant is lower than the feeding level air will enter the pump when lifting up the plunger handle This will cause inaccuracy in dispensing 7 2 Weekly Maintenance 01 Checkif the canister is loose If so tighten the tapping screws under the turntable see 7 5 Replacement of Canister 02 Check if the gauge s scales are damaged or covered with colorant Clean or replace the gauges if necessary 03 Set the black gauge at its full scale lift up the plunger handle to check if the shaft is stuck by colorant If yes the big piston must be replaced because it has been worn out and or broken
5. SANTINT E M3 Manual Dispenser User s Manual Please read this manual carefully before operation 2008 Copyright Paint Mixing Machine All rights reserved Printed in the People s Republic of China Disclaimer No part of this book shall be reproduced stored in retrieval or transmitted by any means electronic mechanical photocopying recording or otherwise without written permission of ZHENGZHOU SANHUA TECHNOLOGY amp INDUSTRY CO LTD While every precaution has been taken in the preparation of this book the publisher assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from the use of information contained herein This document is the proprietary information of ZHENGZHOU SANHUA TECHNOLOGY amp INDUSTRY CO LTD furnished for customer use only No other uses are authorized without written permission of ZHENGZHOU SANHUA TECHNOLOGY amp INDUSTRY CO LTD ZHENGZHOU SANHUA TECHNOLOGY amp INDUSTRY CO LTD reserves the right to make changes without notice to this document and its products This manual contains information that is correct to the best of ZHENGZHOU SANHUA TECHNOLOGY amp INDUSTRY CO LTD s knowledge It is intended to be a guide and should not be considered as a sole source of technique instruction should not replace good technique judgment since all possible situations cannot be anticipated If there is any doubt about exact installation configura
6. TD Postal Address Xushui Industrial amp Trading Park Zhongyuan West Road Zhengzhou City Henan Province P R China 450042 Tel 400 6113711 Fax 86 371 67857221 Email info santint com http www santint com
7. ace touches the bottom surface of the Fine gauge knob 04 Measurement Measure the minimum dispensing quantity of the Rough gauge and Fine gauge respectively according to Dispensing Procedures 5 3 step 2 through 5 05 Compare the measured value with the standard one to find their difference For any difference exceeding the permitted range you ll have to adjust the screw s on the active base or the plunger handle 06 Repeat the step 4 and 5 until you get the required minimum dispensing quantity 7 7 Extended periods on non use For extended periods of non use with colorant still in the canisters the M3 must be kept powered on Dispense some colorant approx 1ml periodically every 5 days to avoid the nozzle from becoming dry and the colorant hardening Otherwise disconnect from power pour the colorant into clean or corresponding canister and clean the canister to avoid the colorant from drying 8 Troubleshooting Symptom Cause Action Check if plug and wire are No power fine Check if socket has power The fuse is broken Replace fuse The motor does not work Open motor case and The motor is disconnected reconnect the motor correctly The motor is broken Replace it See Preparation Before Air bubbles in the cylinder Operation Allow the bubbles to escape Uneven flow of colorant p from the nozzle during Colorant in canister is low Top off colorant dispensing Dried depo
8. ck Spring 7 Plastic Sleeve 17 Lower Turntable 8 Stelliform Plate 18 Motor Shaft 9 Bearing 19 Nut 10 Rotary Plate Santint M3 Manual Dispenser V1 0 15 11 Nameplate SANTINT SANHUA MANUAL DISPENSER A Date of Mfr ZHENGZHOU SANHUA TECHNOLOGY amp INDUSTRY CO LTD Xushui Industrial amp Trading Park Zhongyuan West Road Zhongyuan District Zhengzhou City Henan Province P R China 450042 WEB www santint com Email service santint com FETEIEIT TTE I 7493 1 8534520 FT The power parameter could be found on the name plate 12 Regulatory Information Declaration of Conformity Application of Council Directive s 89 336 EEC EMC Directive Confirm of Conformity Application of Council Directive s 98 37 EC Machinery Directive 73 23EEC Low Voltage Directive Standards to Which Conformity is Declared Machinery Directive Annex 1 EN60204 1 1997 EN292 1 2 EN1050 Manufacturer Name ZHENGZHOU SANHUA TECHNOLOGY amp INDUSTRY CO LTD Manufacturer Address Xushui Industrial amp Trading Park Zhongyuan West Road Zhengzhou Henan 450042 P R China Tel 86 371 67857198 67857178 Fax 486 371 67857221 67857166 Email info santint com Santint M3 Manual Dispenser V1 0 16 APPENDIX APPENDIX 1 EC Declaration of Conformity According to the Low Voltage Directive 73 23 EEC 93 68EEC For the following equipment Product Manual Dispenser Type designation tradema
9. e conformity Other technical documentation e g quality assurance measures for design and Production Responsible for marking this declaration is the Manufacturer Authorized representative established within the EU O Authorized representative established within the EU if applicable Company Name N A Company Address N A Person responsible for making this declaration Full Name Shen Ruhua Position Title General Manager ne ya d Zhengzhou 1 Aug 2006 Ay a Santint M3 Manual Dispenser V1 0 18 APPENDIX 3 Declaration of Conformity According to 2002 95 EC For the following equipment Product Manual Dispenser Type designation trademark M3 Manufacturer s Name Zhengzhou Sanhua Technology amp Industry CO Ltd Manufacturer s Address Xushui Industrial amp Trading Park Zhongyuan West Road Zhengzhou City Henan Province P R China Referred to in this declaration conforms with the following Standards or directive s as far as applicable 2002 95 EC ROHS Directive Responsible for marking this declaration is the Manufacturer HI Authorized representative established within the EU L Authorized representative established within the EU if applicable Company Name N A Company Address N A Person responsible for making this declaration Full Name Shen Ruhua Position Title General Manager Zhengzhou Aug 2006 b d Santint M3 Manual Dispenser V1 0 19 ZHENGZHOU SANHUA TECHNOLOGY amp INDUSTRY CO L
10. ead 9 Large Piston M3 Manual Dispenser Figure 10 1 10 Large Piston Wiper 11 O Ring 9x1 9 12 plug stopper 13 Circlip for Shaft 14 Large Piston Shaft 15 Fixed Base 16 Set Screw M4x6 17 Active Base 18 Black Gauge Coarse Gauge Santint V1 0 12 10 2 Assembly of Canister Figure 10 2 M3 Manual Dispenser Santint V1 0 1 Canister Lid 2 Collar Pin 3 Agitator 4 Shaft Bushing Agitator 5 Canister 6 Crank shaft 7 Screw M6X35 8 Screw M6X30 10 3 Assembly of Canister Pump Figure 10 3 1 Bolt M5X10 2 Piston Kit Gauge 3 Pump Housing 4 Valve Kit 5 O Ring 8X1 8 6 Nozzle 7 O Ring 7 2X1 8 8 Washer 9 Valve Pole 10 O Ring 3 15X1 8 M3 Manual Dispenser Santint V1 0 11 Inhalant Piston 12 Rubber Cover Wiper 13 Wiper 14 Pan head Screw M3X12 15 Valve Handle 16 Torsion Spring 17 O Ring 19X2 65 18 Linking Block 19 O Ring 19X2 1 20 Fixing Bolt Linking Block 21 Canister Kit 10 4 Assembly of Turntable Figure 10 4 1 Bolt 11 Plastic Washer 2 Protection Cap 12 Bolt 3 Upper Turntable 13 Eccentric Shaft 4 Bolt 14 Center Location Tube 5 Riveting Nut 15 Support 6 Bolt 16 Lo
11. irements the daily stir frequency and time can be altered accordingly 6 2 Rotating and Locking of Turntable Countertop Dispenser and Floor stand Dispenser share the same method of turning and locking turntable Please see Floor stand type as an example As Figure 6 2 1 shows Press the brake handle down to the horizontal slot To lock the turntable Base Paint Can 01 Rotate the turntable to the desired position 02 Release the turntable brake handle back up to the vertical slot 03 Move the turntable to the left and right slightly to let the brake handle return to its original position 04 The turntable is now locked Figure 6 2 1 6 3 Dispensing The minimum shot of the dispenser is one division on the Fine gauge s dispensing unit is marked at the bottom For example 2957 384 means the unit is 1 384 US Fl Oz Numbers on the Rough gauge and the Fine gauge have same unit marked at the bottom of the Rough gauge For example if the Rough gauge is marked 2957 48 the number 30 on the Rough gauge represents the dispensing value of 30x29 57 48ml and number 2 on the Fine gauge Santint M3 Manual Dispenser V1 0 5 represents the dispensing value of 2x29 57 48ml Dispensing Procedures 01 Determine the dispensing quantity of different colorant as per the formula 02 Put an open base paint can on the shelf pull the turntable brake handle down into the horizontal slot and rotate the turntab
12. issing parts The machine must be placed in a well ventilated place Otherwise an aerator must be provided The applicable power cord refer to the nameplate in the rear Make sure the power cord is well grounded to ensure safety Do not lengthen the power cord as to avoid malfunction or injury Before servicing and repairing remove power cord from wall socket If the dispenser is not used for a long time unplug from wall socket Do not operate in a flammable and explosive environment Santint M3 Manual Dispenser V1 0 1 3 Configuration Brake handle Button As Figure 3 1 1 Figure 3 1 2 shows D 6 urntable i f DA i Canister Canister Lid j Rough Rease Button Fine Rease Button Rough Gauge Fine Gauge Plunger Handle Pump amp 62 C 2 Nozzle Valve Handle Shelf Stand O PB OOOSOORDOGHHLOO Figure 3 1 1 Figure 3 1 1 Santint M3 Manual Dispenser V1 0 2 4 Major Specifications Model M310 M312 M314 M316 M320 M324 bui 9r 10 12 14 16 20 24 Canisters Power Supply See Nameplate Rated Power 80W Dispensing 20rpm Speed Canister s 2 3L Volume USOZ Min US Fluid Ounce 0 077ml 1 384 US Dispensing US Metric Fluid Ounce 0 081 ml 1 384 METRIC Quantity Metric 0 1ml OZ Da 745X745X 745X745X 860X860X 860X860X 1016X1016X 1150X11 1300 1300 1300
13. le until the nozzle is right above the base paint can Push the turntable brake handle up to the vertical slot and move the turntable left and right slightly to lock the turntable See Figure 6 2 1 Attention Please put the base paint can as close as possible to the spout 03 Press and hold the Rough or Fine button as required lift up the Rough or Fine gauge to required number and then release the button to lock the gauge See Figure Fine Gauge 6 3 1 Rou eee 04 Lift up the plunger handle up to the M Plunger Handle maximum travel and hold for several seconds to ensure the pump is filled with colorant Attention Do not open or operate the valve handle when lifting up plunger handle otherwise air will enter into the P9 9h Release Button pump and cause inaccurate dispensing Fine Release Button 05 Turn the valve handle to an angle of 90 Figure 6 3 1 pull the plunger handle down to its full travel then release the valve handle slowly back to its original position Repeat the above procedures for more shots of the same colorant See Figure 6 3 2 06 Press down Rough release button push the Rough gauge back to zero scale and then release the Rough release button 07 Press down Fine release button push the Fine gauge back to zero scale and then release the Fine release button Attention Valve Handle As a precise device either Rough or Figure 6 3 2 Fine gauge is vulnerable to damage Santint
14. nto a clean container Clean the canister with warm water to get rid of most of the adhesive colorant Properly dispose the mix of cleaner and colorant according to local environmental regulations Reinstall the canister on the turntable Add some cleaner into the canister Set the Rough gauge to its maximum scale Put a container right below the nozzle and then operate as dispensing procedures 6 3 Set the Fine gauge to its maximum scale Place a container right below the nozzle and then operate as dispensing procedures 6 3 Repeat steps 7 9 until the canister is clean the cleaner can be used for 1 3 times Yet fresh cleaner is required for the final cleaning Leave the canister to dry before re filling with fresh colorant Santint M3 Manual Dispenser V1 0 8 7 5 Replacement Replace Sniff Back Piston 01 02 03 04 05 06 Rotate the valve handle and pull out the nozzle Rotate the valve handle to its maximum travel and hold Pull out the sniff back piston Install a new sniff back piston with small O ring Reinstall the nozzle Release the valve handle Replace Canister 01 02 03 Rotate the canister anti clockwise shift Loosen but do not remove the three screws that fix the canister under the turntable using the inner hexagon wrench Rotate the canister clockwise to remove from the Put the top of the screw into the big part hole turntable While installing the new canis
15. pen the shelf by pulling it down See figure 5 2 2 1 Move the shelf up and down to an appropriate height Press it gently so that it can be locked into the grooves of the location plate See Figure 5 2 2 2 Return the shelf back to ji its original position when it is not in use 5 2 3 Step C Check air inside canisters On the shelf place a clean container just below the nozzle e Lift up the plunger handle slowly to its highest position rotate the valve handle with your left hand to an angle of 90 as shown in Figure 5 2 3 and then push down on the plunger handle slowly Meanwhile observe if the colorant flows continuously If the colorant flow is discontinuous or if the colorant leaks Valve Handle Figure 5 2 3 from nozzle while valve handle is being Figu Santint M3 Manual Dispenser V1 0 4 rotated that is an indication that air remains in the pump In this case return the valve handle to its original position and repeat step A until the colorant flows out at an even stream This indicated that all air is pressed out Finally pour the colorant in the container back into the corresponding canister Follow the same operation for other pumps The dispenser is ready for use 6 Operation 6 1 Colorant Mixing Connect power cord to a wall socket and press the button to initiate mixing To stop mixing repress the button Stir 3 times every day at 10 minutes time intervals If client has special requ
16. rk M3 Manufacturer s Name Zhengzhou Sanhua Technology amp Industry CO Ltd Manufacturer s Address Xushui Industrial amp Trading Park Zhongyuan West Road Zhengzhou City Henan Province P R China Referred to in this declaration conforms with the following standards or directive s as far as applicable ENG0204 1 1997 Responsible for marking this declaration is the Manufacturer Authorized representative established within the EU LJ Authorized representative established within the EU if applicable Company Name N A Company Address N A Person responsible for making this declaration Full Name Shen Ruhua Position Title General Manager Zhengzhou 1 Aug 2006 D d d Santint M3 Manual Dispenser V1 0 17 APPENDIX 2 EC Declaration of Conformity According to the Machinery Directive 98 37 EC For the following equipment Product Manual Dispenser Type designation trademark M3 Manufacturer s Name Zhengzhou Sanhua Technology amp Industry CO Ltd Manufacturer s Address Xushui Industrial amp Trading Park Zhongyuan West Road Zhengzhou City Henan Province P R China Refer to in this declaration conforms with the following directive s Annexl of the Machinery Directive 98 37 EC The company named above will keep on file for reviewing the following technical documentation Operating and maintenance instructions Technical drawings Risk assessment Description of measures designed to ensur
17. se bos se an ann a Pa Ese pb ab SES eso FREIER an Ee RE aa Sian 10 9 Circ it Diagram ue o SooS 11 10 Assembly Drawings INNER ada nan a ae A aaa ia ena Banana 12 10 1 Assembly of Piston Kit rre Ih RH RER Ee eter O ER A A ARE 12 10 2 Assembly of Canister vin nene eie eem tete d oii ee inden esee gea ees 13 10 3 Assembly of Canister Pump 5 secas teet cei tte eei iier ten Sea eSa eri anekani aas 14 10 4 Assembly of Turntable neesan eoero nete AA ee eet dne dette te debere 15 MD Nevin plate erae E aaa aii naaa 16 12 Regulatory Information eee esee KA SABAK AA AANS A ses A ida a 16 APPENDIX nn nn an arian aaas aaa a a an ana a an ana ana 17 APPENDIX Li A A ii 17 APPENDIX Qro REM 18 APPENDIX 3S nn M 19 Santint M3 Manual Dispenser V1 0 iii 1 Preface Thanks for purchasing the Santint Manual Dispenser This user s manual provides general information on installation usage and maintenance of our manual dispenser Any improper use will shorten its longevity Read this manual completely and carefully before installation use and maintenance of the machine The manual should be kept in a convenient place for future reference For any questions please do not hesitate to contact our service team 2 General Safety Instructions 1 The ambient temperature shall not be below 5 C 2 Take notice Checkthe wooden case for m
18. sits of colorant causing Clean canister assembly and blocks relevant parts Santint M3 Manual Dispenser V1 0 10 Canister is loose on Loose fastening screws Tighten fastening screws turntable Colorant doesn t dispense Nozzle blocked Clean nozzle easily Canister and pump should be Colorant has dried and hardened removed emptied and cleaned in the canister thoroughly Replenish with new colorant Piston doesn t move easily The crank shaft under the canister is not attached to the plastic Reinstall the canister sleeve of the rotating panel Agitator doesn t move during mixing Colorant leakage at the Worn out O ring Replace O ring nozzle d ng P ng 9 Circuit Diagram See Figure 9 1 AC230V 50Hz PE N L Earth 4 i Connection Terminal ia u Terminal FUSE D Light Button 13 Es 16 23 L 24 Control Q AL 14 x 15 Hm Switching EIE SP n Power Supply cwe AN DC eMe M Motor Figuresantint M3 Manual Dispenser V1 0 11 10 Assembly Drawings 10 1 Assembly of Piston Kit 18 1 Screw M4x10 2 Plunger Handle 3 Screw M4x10 4 Red Gauge Fine Gauge 5 Small Piston Shaft 6 Small Piston 7 8mall Piston Head 8 Large Piston H
19. ter place the three M6 screws at the bottom of the canister into the larger ends of the three cone shaped holes in the turntable Caution Must insert the canister ATTENTION Must put the paddle shaft into the star plate hole crank into the plastic sleeve in the turntable see Figure 7 5 1 the canisters three screws to the Figure 7 5 1 smaller ends of the cone shaped holes and then fix the screws with inner hexagon wrench from the bottom of the turntable 7 6 Calibration Normally the machine has been precisely calibrated and ready for use before leaving the factory Yet in the following cases new calibration is necessary When replacing either the Rough or Fine gauge or the location pin of the said gauge The dispensing result is not accurate Calibration procedures as follow 01 Check the condition of the Rough or Fine gauge or their location pin Replace them if necessary 02 Press and hold the Rough button until the black gauge reaches zero scale Release the Rough button back to the original position Use an inner hexagon spanner to adjust the Santint M3 Manual Dispenser V1 0 9 screws on the active base until its top surface touches the bottom surface of the gauge knob 03 Press and hold the Fine button until the red gauge reaches zero scale Release the Fine button back to the original position Use an inner hexagon spanner to adjust the screw on the plunger handle until its top surf
20. tion and or use call ZHENGZHOU SANHUA TECHNOLOGY amp INDUSTRY CO LTD The choice of system components is buyer s responsibility ZHENGZHOU SANHUA TECHNOLOGY amp INDUSTRY CO LTD holds no liability for their use However ZHENGZHOU SANHUA TECHNOLOGY amp INDUSTRY CO LTD s sales team and application engineers are always available to assist you in making your decision Santint M3 Manual Dispenser V1 0 i ZHENGZHOU SANHUA TECHNOLOGY amp INDUSTRY CO LTD QAC amp Quality Assurance Centre of China Association for Quality CERTIFICATE OF QUALITY MANAGEMENT SYSTEM Certificate No 00607Q10059R1M This is to certify that the Quality Management System of Zhengzhou Sanhua Technology amp Industry Co Ltd Address Xushui Industrial amp Trading Park Zhongyuan West Road Zhengzhou Chy Henan Province People s Repoblie of Chime Post Code 450042 is in conformity with GB T 19001 2000 idt ISO 9001 2000 This certificate is valid to the following scope Design Manufacture and Services to its Series Products Paint Mixing and Dispensing Machines Such as Paint Mixing Machine and Mixing Lids for Car refinishes Dispenser Shaker and Mixer for Decorative Paint Exclusion Item 7 5 2 Term of validity of this certificate from 11 hJan 2007 to EOth Jan 2010 Representative Ag KA Huang Jinfu General Manager Issue Date Iih Jan 2007 Santint M3 Manual Dispenser V1 0 Content Iz A EE AAA A EA AA AA EA A AE Cade eo