Home
Digital Multimeter Model C.A 5205
Contents
1. 10 4 Repair and calibration To guarantee that your instrument complies with the factory specifications we recommend that the Model C A 5205 be submitted to our factory service center at one year intervals for recalibration or as required by other standards For instrument repair and or calibration please call our factory toll free at 800 945 AEMC 800 945 2362 CHAUVIN ARNOUX Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Tel 800 954 2362 603 749 6434 Fax 603 742 2346 Or contact your authorised distributor Estimates for repairs normal recalibration and and calibration traceable to N I S T are available upon request Overseas customers must receive written authorisation before returning any instrument 10 5 Technical and Sales Assistance If you are experiencing any technical problems or require any assistance with the proper use or application of this instrument please call our technical hotline CHAUVIN ARNOUX Inc d b a AEMC Instruments 200 Foxborough Blvd Foxborough MA 02035 USA Tel 800 343 1391 508 698 2115 Fax 508 698 2118 www aemc com
2. of the batteries is indicated approximately on the diode function on open circuit 7 3 Buzzer W Continuous beep for the continuity test W Intermittent beep each time the switch or buttons are pressed and for the overload indication 7 4 Climatic conditions Mi Temperature Use 0 C to 450 C Storage 20 C to 60 C Mi Relative humidity Use lt 70 RH Storage lt 90 RH up to 45 C W Altitude use lt 2000 m 7 5 Conformity with international standards 7 5 1 Electrical safety IEC 1010 1 EH Doubleinsulation a W Installation category Ill Mi Degree of pollution 2 W Assigned voltage 600V Note This multimeter of overvoltage category Ill satisfies the severe requirements of reliability and availability corresponding to industrial and domestic permanentinstallations IEC 664 1 7 5 2 Electromagnetic compatibility conforms to CE Mi Emission EN 50081 1 Immunity EN 50082 1 7 5 3 Mechanical protection W Degree of watertightness IEC 529 protection index IP 40 8 TO ORDER Usethe designations and references below CASZOS ndo danesa Cat 2116 73 Supplied with its shockproof case a pair of leads with probes attached two 1 5V AA batteries and this user s manual Accessories and spares m AC current probe model MN 251 200A AC Cat 2115 77 m AC current probe model MD 303 500A AC Cat 1201 21 m AC current probe model SR 652 1000 A AC Cat 2113 46 m AC DC
3. Digital Multimeter Model C A 5205 User manual EJAEMC Meaning of the symbol A Warning Please refer to the User s Manual before using the instrument In this User s Manual the instructions preceded by the above symbol should they not be carried out as shown can resultin a physical accident or damage the instrument and the installations Meaning of the symbol H This deviceis protected by adoubleinsulation or by areinforced insulation No linking is required fromthe protection earth terminal to ensurethe electrical security Thank you for purchasing a C A 5205 Multimeter To get the best service fromthis instrument W read this user s manual carefully i respect the safety precautions detailed A SAFETY PRECAUTIONS A W Never useon voltage to earth circuits above 600V with a voltage surge category of over Ill thatis to say fixed industrial and domestic installations ref IEC 664 1 MM To be used indoors in environments with a maximum pollution degree of 2 ref IEC 664 1 a temperature between 0 and 50 C and relative humidity below 70 W Use accessories which conform to safety standards IEC 1010 2 031 with a minimum voltage of 600 V and a voltage Surge of category Ill W Never open the multimeter case before disconnecting from any electrical source W Never connect up to a circuit to be measured if the multimeter case is not closed correctly Mi Before any measurements are taken ensure the lea
4. current probe model MR 410 400 A AC 600 A DC e Cat 1200 70 E AmpFLEX model 1000 24 1 1 1000A AC Cat 2112 39 M Replacement leads cccooconinnininconoonnncncncccncnnonanoconons Cat 2118 66 E SOM CONG ING CaSe sesemaiatsmommint0tmtm ents miss Cat 2118 65 m Replacement SNOCKproof CASE coocococccccccccconnnnncccnononos Cat 2980 15 9 WARRANTY Our guarantee is applicable for three years after the date on which the equipmentis made available copy available on request 10 MAINTENANCE For maintenance use only specified spare parts The manufacturer will not be held responsible for any accident occurring following a repair done other than by its After Sales Service or approved repairers 10 1 Replacing the batteries A The multimeter must be disconnected from any electrical source W Place the selector switch on the OFF position E Unscrew the tool release screws and remove the lower half of the case W Replace the dead batteries by two AA 1 5V batteries type LR6 or R6 MB Refit the lower half of the case 10 2 Storage If the multimeter is not put into service for a time exceeding 60 days remove the batteries and store them separately 10 3 Cleaning A The multimeter must be disconnected from any electrical source To clean the case use a cloth slightly moistened with soapy water Rinse with a damp cloth Then dry rapidly with a cloth or ina hotair stream
5. ds and switch are in the correct positions W Never measure resistances on a circuit with the power switched on CONTENTS 1 Presentation nic ous 3 2 lt 8 6 cacao ere eee eee ee eee ee 4 3 DC and AC voltage Visas 4 4 Resistance Q M ssserrerrreek kk tk tk REE ERE KEE ERE E ERE ENE E ERE E ERE ERE E REDER RES 5 5 Continuity beeper iia andan 5 6 DiOde teSt PE oe ceccccceecceeeeeeeeeeeeeeeeaeeeeeeeeeneeeanaeeaeaneeeeeeeenaees 5 7 General SPeCIFICALIONS ccccccconornrocioninnnnaarn cnn nnnonncnnnonanenos 6 8 Accessories and spares TO Order ccccccccccnccnccnccncnnnncononnnnos 7 e 06 EEE E EE E 7 10 Maintenance oooocccccnnncncnnonnnnoncccnnnonnnonononnnrrrnnnnnnnnnnonanarernnnnnnnss 7 Technical and Sales Assistance ccccccccccncnononnconononcnoncononnnnnnnos 8 1 PRESENTATION The C A 5205 is designed for the daily needs of professionals in electricity 2000 counts Automatic recognition of AC and DC Automatic or manual range selection Various measurement accessories broaden the scope of application or provide the multimeter with new functions See the list of accessories and references on the To Order page Documentation upon request Note Always use accessories Suitable for the voltage and the voltage surge category of the circuit to be measured as per IEC 1010 2 DESCRIPTION D LIQUID CRYSTAL DISPLAY EE 2000 measurement counts height
6. of digits 0 65 Rate 2 measurements second Ei low battery indication E Overload indication the 1 on the left flashes e CONTROL BUTTONS HOLD Hold button freezes the measurement on display Rangeselection Press the range button to change from automatic mode to manual mode The automatic mode is selected when the instrument is switched on Note The 200 mV AC range is only accessible on manual Press 3 times on the RANGE button to access this range FUNCTION SELECTOR SWITCH Off position DC and AC voltages up to 600 V Continuity sound testfora resistance R lt 700Q9 2 Resistances up to 20 MQ TERMINALS 4 mmsafety terminals Hi COM common black NM red 3 DC AND AC VOLTAGE Mi Connectthe leads to the multimeter and connectitin parallel to the circuitto be tested W Place the selector switch on the voltmeter function V Automatic selection of the range and the DC or AC mode read the value measured W Freeze the value if necessary by pressing the HOLD button on DC 1l 9o reading 1count On AC l fo reading 5 counts 600 V rms and 900 V peak 1 Use on frequency 40 Hz to 500 Hz Min threshold on VAC 25 mV from 40 Hz to 100 Hz and 300 mV from 100 Hz to 500 Hz Min threshold on V DC 10mV 4 RESISTANCE A Never test a resistance on a live circuit NE Connect the leads to the multimeter and to the circuit or the componentto be tested MM Place the selector swi
7. tch on the ohmmeter function Q Mi Automatic range selection read the measured value W Freeze the value if necessary by pressing the HOLD button 1 5 rdg 15 rdg 3 rdg 5 counts 5 counts 3 counts orog Accuracy Voltageon opencircuit Protection 500 V rms and 750 V peak lt 0 5V 5 CONTINUITY BEEPER W Placethe selector switch on the en function W Continuous audible beep emitted for a resistance R lt 700 Q 6 DIODE TEST A Never test a diode on a live circuit NE Connectthe leads to the multimeter and to the terminals of the component to be tested VVith this function itis possible to test besides classic diodes LED s or any other semiconductor in which the junction corresponds to a direct voltage less than 3V W Place the selector switch on the gt function in fonvard direction the display gives the value of the junction in V resolution 1 mV accuracy 2 rdg 15 mV open circuit voltage 1 5V typical Short circuit current 0 4 mA in reverse direction the display indicates the open circuit voltage around 2V W Freeze the value if necessary by pressing the HOLD button W Protection idem Resistances 7 GENERAL SPECIFICATIONS 7 1 Dimensions and weight E 2 5 x7 x 1 7 64x177x42mm _ W 12 3 ounces 3509 7 2 Powersupply W Two batteries 1 5V type R6 W Battery life 300 h with RO batteries 500 h with alkaline battery LR 6 W Low battery indication Esp Note Thevoltage
Download Pdf Manuals
Related Search
Related Contents
User Manual MANUAL DE INSTALACIÓN manual da declaração do simples nacional Bulletin technique - Bayer Environmental Science G一岬ーM 剛 “R 眠” 一 ` 一 SILLINGER 650 PRORAID.ai MELSEC iQ-R Digital-Analog Converter Module User`s Manual Ergotron DS Series DS100 Dual Monitor Desk Stand, Vertical Copyright © All rights reserved.