Home
owner`s manual - Dufour Yachts Magyarország
Contents
1. 68 220V airconditioning installation plan 70 Power generator plan 72 ENGLISH 22 04 2013 6 74 DUFOUR 450 Grand Large INTRODUCTION DUFOUR YACHTS is pleased to present you with this Manual which will help you get to know your boat better This Manual has been produced to help you use your boat safely and enjoyably It contains details of the boat the equipment supplied or fitted its systems and information about their use Read it carefully and familiarize yourself with the boat before using it This Owner s Manual is not a course in sailing safety or seamanship If this is your first boat or you are changing to a type of boat you are unfamiliar with for your convenience and safety make sure you gain experience handling and using it before taking command Your agent your national sailing or cruising federation or your yacht club will be happy to give you information about sailing schools or qualified instructors in your area Ensure that forecast wind and sea conditions correspond to the design category of your boat and that you and your crew are capable of handling the boat in these conditions Even when your boat is suitable for them the sea and wind conditions corresponding to design categories A B and C vary from severe storm for category A to severe conditions for the top end of category C subject to dangers of abnormal gust
2. 29 1 Mtt 20 2 Deck quit go mmc 32 34 4 Halyard and sheet operating 4 36 2 220 V circuit diagram 38 6 220 V electrical installation diagram 40 7 Fuse location diagram E 42 8 Charging amp power circuit diagram 44 9 12 V distribution panel diagram 46 10 Electrical panel terminal 4 48 11 12 V electrical installation diagram 50 12 Steering system 0 2208 52 13 system diagram 54 14 _ Ship E 56 15 Fresh walfer system diagram assum 58 16 Drain system E E 60 17 Skin fitting location diagram no ua uae anta
3. 3 the cockpit 2 kg powder extinguisher Wh Engine compartment extinguishing hole EXIT Emergency exit Not supplied ENGLISH 22 04 2013 Page 56 74 DUFOUR 450 GRAND LARGE ENGLISH 22 04 2013 Page 57 74 DUFOUR 450 GRAND LARGE 15 Fresh water system diagram 3 3 Description O Filler deck plate Filler hose Vent Vent hose 250 L aft water tank Hot water pipe 1 2 2 way manifold Water pump unit Fresh water pump Water heater Bathroom mixer tap Galley mixer tap Deck hand shower 280 L fore water tank Cold water pipe 34 Male bolt Yo t1 turn FF valve 34 WX F connector Ya WX M connector Head shower single lever mixer tap ENGLISH 22 04 2013 Page 58 74 DUFOUR 450 GRAND LARGE G Fig 16 Drain system diagram ENGLISH 22 04 2013 Ref Description JO Electric bilge pump D20 3 4 valve strainer 220 discharge hose Electric bilge pump 3 4 skin fitting Manual bilge pump D25 valve strainer 225 discharge hose Manual bilge pump 1 skin fitting Page 60 74 DUFOUR 450 GRAND LARGE Page 61 4 UUFUUR 450 GRANU LARGE
4. 5 2 d 45 5 ENGLISH 44 04 4013 Page 51 4 UUFUUK 49U URANU LARGE 12 Steering system diagram Ref Description Rudder blade Rudder stock Steering column Tiller deck plate Rudder trunk Steering wheel Autopilot Bulkhead fitting brake 9 Chain assembly 05 cable 10 Pull Push duct 11 Sleeve terminations and Rudder stop set 12 Quadrant 13 Thrust bearing 14 JP3 bearing oa 8 Option ENGLISH 22 04 2013 Page 52 74 DUFOUR 450 GRAND LARGE 1235 SV 2 Bea LS ENGLISH 22 04 2013 53 74 DUFOUR 450 GRAND LARGE 13 Gas system diagram Ref Description 1 8 kg gas cylinder CE shut off valve Fr or Ger 30 mbar CE regulator Fr or Ger pressure gauge Medium length connecting hose Spacer 6x8 pipe Watertight bulkhead fitting PVC pipe 6x8 copper pipe CE gas shut off valve in compartment below cooker Long connection hose 3 burner stove oven o 3 2 Not supplied ENGLISH 22 04 2013 Page 54 74 DUFOUR 450 GRAND LARGE ENGLISH 22 04 2013 Page 59 74 DUFOUR 450 GRAND LARGE 14 Abandon ship plan Ref Description Ex Recommended fire extinguisher locations 1 Under chart table 2 kg FM 200 fire extinguisher 2 Under saloon settee 2 kg powder extinguisher
5. 11 12 V electrical installation diagram Ref Description Windlass Windlass relay Windlass remote control 25 A battery charger Bulkhead light switch Diesel gauge Fresh water gauge Cockpit speaker 12V control panel Steering compass Auxiliary fuse Navigation lights Steaming light Mooring light Deck light Solenoid valve Gas alarm detector panel Autopilot motor Shower pump control Refrigeration unit Shower waste pump Electric bilge pump 100 Ah engine battery 100 Ah auxiliary batteries 2 2 Water pump unit Motor fan Chart table reading light Engine and auxiliary battery isolator Splitter Alternator Starter motor Speed sensor transducer Spotlight Reading light Saloon speaker Plug socket Indirect lighting control Courtesy lighting control Courtesy lighting Indirect lighting Option N Ro o Moo o ck ck 0 0 N ENGLISH 22 04 2013 Page 50 74 DUFOUR 450 GRAND LARGE V3 SH Sf IC TES 2 1 Siji St Dt ir e HI NL WHE 2 1 1 gt UI LE uma amp
6. 38 6 220 V electrical installation diagram 40 7 DELE 42 ENGLISH 22 04 2013 5 74 DUFOUR 450 Grand Large 10 11 12 13 14 15 16 17 18 19 20 21 22 Charging amp power circuit diagram n 44 12 V distribution panel diagram tnn 46 Electrical panel terminal 0 0 48 12 V electrical installation diagram 50 Steering system diagram 52 system CIA QIAN eae aaa Y 54 Abandon ship plan 56 Fresh water system diagram nana tah 58 Drain system dlagram a 60 Skin fitting location diagram 1 eee 62 Engine installation diagram ana sa 6 Holding tank installation diagram 66 Lifting AQUAIN
7. Operation of the sea toilets 17 Holding tank operation 17 VEEL OODING 18 VIL FIRE 18 Installation 18 Safety instructions 19 KENE NEE 79 General precautions 19 Exhaust gas emissions 20 Safety 20 Wintering 21 IX FUEL INSTALLATION ice 21 X STEERING SYSTEM eee 27 Helm 21 Emergency tiller 22 ARSALIN G EE o 22 Maintenance 23 Protection of persons during a storm 23 ENVIRONMENTAL PROTECTION ans 23 XV HANDLING TRANSPORTING eiie eese seen nnns nn nn naar rash narrans 24 XVI GUARANTEE TRANSFER OF OWNERSHIP eese esee ee esee nenne nana nnns 25 DIAN 29 Accommodation layout E 30 2 61111 05 DIAN 32 3 aa 2 Halyard and sheet operating 36 5 220 circuit diagrai
8. the codes of good practice ENGLISH 22 04 2013 23 74 DUFOUR 450 Grand Large XIV SAFETY FACILITIES There is no harmonization of mandatory safety equipment across the European Community You should find out about current national requirements for CE marked vessels In France the skipper is responsible for ensuring that recreational craft bearing the CE mark carry aboard the mandatory handling and safety equipment stipulated for the relevant sailing category Your boat is provided with a stowage position for a life raft read the life raft instruction manual carefully The crew must be made familiar with the use of all the safety equipment harnesses flares life raft etc Sailing schools and clubs regularly organize training sessions Advice for hoisting a person up the mast XV HANDLING TRANSPORTING HAULOUT When craning take care that the slings are correctly positioned and are not fouling the propeller the sail drive or a fragile transducer Lifting frames must be wide enough or fitted with spreaders so as to avoid applying excessive lateral pressure on the rubbing strakes Avoid allowing slings to foul the life lines During transport or haulout the keel should be in proper contact with its support and should be taking most of the boat s weight Cradle pads must be positioned against structural elements and exert only the pressure necessary for the boat to be properly balanced Take advantage of the opportunity
9. 17 Skin fitting location diagram Ref Description Skin fittings seacocks 1 Galley sink discharge 1 2 Washbasin discharge 1 3 WC water intake 3 4 4 Toilet discharge 2 5 Shower waste 3 4 6 pump sea water intake 1 2 Skin fitting 7 Electrical bilge pump discharge 3 4 8 Manual bilge pump discharge 1 Strainer skin fitting 9 Air con seawater intake 10 Desalinator seawater intake 11 Power generator seawater intake 12 Aircon discharge 13 Desalinator discharge Option ENGLISH 22 04 2013 Page 62 74 DUFOUR 450 GRAND LARGE am 5 8 deo 13 2 11 33 EE EE la _ dn G 00065 121 M EL du i ME 18 Engine installation diagram ENGLISH 22 04 201 Re Th Description WD 10 11 12 13 14 15 16 17 18 19 20 1 22 23 30 24 25 26 27 28 29 Sail drive Engine sea water pump Polyester frame Isolator Propeller Anode Cooling system Exhaust Seawater valve on sail dr
10. Address owner of DUFOUR 450 No confirm that have received the Owner s Manual for my DUFOUR 450 and accept its being written in English Dated Signature ENGLISH 22 04 2013 3 74 DUFOUR 450 Grand Large Cette page est blanche intentionnellement This page is intentionally left blank Cette page est blanche intentionnellement This page is intentionally left blank Cette page est blanche intentionnellement This page is intentionally left blank ENGLISH 22 04 2013 4 74 DUFOUR 450 Grand Large 5 INTRODUCTION O 7 L GENERAL INFORMATION Design category 8 Certification 8 Identification 8 Degrees of danger 9 Il PRINCIPAL SPECIFICATIONS 7 Il ELECTRICAL SYSTEMS iioi EAA 77 Safety and operating instructions for the electrical system ISO 10133 11 Installing new equipment 11 Batteries 12 Electric windlass 12 220 110 Volt installation 13 Operating advice 14 Checking the system 15 Changing the gas cylinder 15 V DRAIN amp SANITATION SYSTEM ea ENEE 16 Specifications of the drain system 16 Pressurized fresh water pump 16
11. Page 72 74 DUFOUR 450 GRAND LARGE DOO 6 9 9 0 n 7 7 KER E Le Sg SS bbb ENGLISH 22 04 2013 Page 73 74 DUFOUR 450 GRAND LARGE 5 ENGLISH 22 04 2013 Page 74 74 DUFOUR 450 GRAND LARGE
12. draught 2 20m ENGLISH 22 04 2013 Page 68 74 DUFOUR 450 GRAND LARGE ENGLISH 22 04 2013 69 74 DUFOUR 450 GRAND LARGE 21 220 airconditioning installation plan 5 T Description 01 PS ON O Reversible airconditioning Seawater intake pump Seawater filter Skin fitting seawater intake valve Air intake grille Ducts Transition unit Air blower grille Skin fitting elbow seawater discharge Sea water hose Option ENGLISH 22 04 2013 Page 70 74 DUFOUR 450 GRAND LARGE 1 AE 82 SEH A 4 06 0 0 04 DUFOUR 450 GRAND LARGE 22 Power generator plan ENGLISH 22 04 2013 Ref Description General 1 Power generator Cooling system Exhaust system 2 Seawater inlet 3 Seawater 056 4 Seawater filter 5 Exhaust pipe 6 Exhaust outlet 7 Anti siphon elbow 8 Exhaust pipe 9 Water separator 10 Expansion tank Fuel system 11 Fuel tank vent 12 Fuel tank hose 13 2501 Fuel tank 14 Fuel shut off valve 15 Fuel feed 056 16 Fuel return 056 17 Diesel pre filter 18 Fuel filler deck plate 19 Diesel pump 20 Filler hose Miscellaneous 21 Electronic unit 22 Control panel Option
13. in order to prevent boat movement and or rotation of the propeller On subsequent launches a brief check of propeller fixing can be made Incorrect operation of the folding propeller will lead to vibration Regularly check the condition of the anodes and ensure that they are suitable for the boat s environment fresh water salt water Change the anodes every year The 3 anodes have an average life of 1 2 years These anodes are made of zinc It is essential not to use magnesium ones Impressed current cathodic protection systems should not be used If the anodes are not eroded you need to check that they have not been painted over that they are correctly fixed and in contact with the hull and that they are indeed made of zinc Exhaust gas emissions DANGER Internal combustion engines produce carbon monoxide Prolonged exposure to exhaust gasses can have serious consequences and may even cause death Safety DANGER In order to avoid all risk of serious injury from the propeller the engine must not run when there are people swimming near the boat Whenever possible the engine must be stopped for any engine maintenance or checking operations If this is impossible then particular care must be taken with moving parts propeller shaft belts etc to avoid any danger of injury ENGLISH 22 04 2013 20 74 DUFOUR 450 Grand Large Wintering Read carefully the operating and maintenance instructions for the engine that co
14. reminder of safety practices or attracts attention to hazardous CAUTION practices that may cause injuries or damage to the boat its components or the environment 1 PRINCIPAL SPECIFICATIONS Model DUFOUR 445 Grand Large Designer Umberto Felci Interior design DUFOUR Design Design category A Notified body No CE 0607 Engine LOA Lmax 13 50 Hull length Ly 13 25 LWL 11 92 Maximum beam Bmax 4 34 beam 4 34 m Draft deep ballast 2 20 Deep ballast weight 2850 kg Light displacement deep ballast 10275 kg Displacement at maximum loading deep ballast 12885 kg Draft shallow ballast 1 95 Shallow ballast weight 3000 kg Light displacement shallow ballast 10425 kg Displacement at maximum loading shallow ballast 13035 kg Air draft standard 18 50 m Standard mainsail area approximate 43 5 m Genoa area approximate 50 5 Water capacity excluding 20 L water heater 530 approximate Diesel capacity approximate 250 L Holding tank standard optional 501 501 Engine battery 100 Ah Auxiliary battery 2 as standard 2 as option 2 x 100 Ah 2 x 100 Ah option Primary means of propulsion Sail Maximum permissible on board engine power 75 55 kW Total weight of liquids all tanks full 742 kg NB due to the trim and loading of the boat it is not usually possible to use the
15. whole of the various tank capacities for fresh water and diesel You are recommended to maintain a diesel reserve of 20 ENGLISH 22 04 2013 10 74 DUFOUR 450 Grand Large III ELECTRICAL SYSTEMS Safety and operating instructions for the electrical system ISO 10133 If a fuse or circuit breaker blows continually you should consult a specialist to determine the cause of the short circuit Installing new equipment Since 1 January 1996 electrical equipment is subject to the European electromagnetic compatibility directive Ref 89 336 CEE So new equipment being installed must meet this standard and bear the CE mark Equipment must also be supplied with a compliance certificate and instructions for use In the case of 220 or 110 V installations use only double insulated or earthed equipment When such equipment is being installed respect the fitting instructions conductor size protection To avoid maintenance problems be sure to enter in the manual any modifications that may have been made to the electrical circuits ENGLISH 22 04 2013 11 74 DUFOUR 450 Grand Large Batteries The battery facilities consist of two 100 Ah auxiliary batteries as standard in the technical space between the aft bunks with two supplementary 100 Ah batteries as an option for engine starting Their capacities have been designed to handle the power requirements of the on board accessories To avoid any problems it is necessary to keep a close eye on t
16. 30 Triple ratchet block Life line anchor point on port amp starboard cleats B Towing points Port amp Starboard C Hatches must be closed when sailing D overboard reboarding E Space provided for stowing life raft F Anchor point for safety harnesses G Lockers must be closed when sailing Option ENGLISH 22 04 2013 Page 32 74 DUFOUR 450 GRAND LARGE 9 9 50 SSS 6 6 EX 0 e 5 gt 7 DUFOUR 450 GRAND LARGE Page 33 74 ENGLISH 22 04 2013 3 58 diagram 15 80 m 5 00 14 85 5 10 LP 140 overlap 7 00 Mainsail area 43 5 m Genoa area 140 55 0 Jib area 108 42 5 m Gennaker 130 m Not supplied ENGLISH 22 04 2013 Page 34 74 DUFOUR 450 GRAND LARGE ENGLISH 22 04 2013 35 74 DUFOUR 450 GRAND LARGE 4 Halyard and sheet operating diagram ENGLISH 22 04 2013 Ref Description standard mast 1 Spinnaker tack 2 Spinnaker halyard 3 Mam halyard 4 Reef line 1 5 Mainsheet 6 Adjusting Mainsail car 2 7 Adjusting Mainsail car 1 8 Boom vang 9 Mainsail foot 10 Reef line 2 11 halyard 12 Releasable forestay chain plate or self tacking jib sheet 13 Spinnaker sheet 14 Genoa she
17. DUFOUR YACHTS OWNER S MANUAL INACCORDANCE WITH EUROPEAN DIRECTIVE 94 25 EC AS AMENDED BY EUROPEAN DIRECTIVE 2003 44 EC DESIGN CATEGORY A ENGLISH 22 04 2013 1 74 DUFOUR 450 Grand Large Cette page est blanche intentionnellement This page is intentionally left blank Cette page est blanche intentionnellement This page is intentionally left blank Cette page est blanche intentionnellement This page is intentionally left blank ENGLISH 22 04 2013 2 74 DUFOUR 450 Grand Large Your agent is DUFOUR YACHTS representative and will give you all the help you need to resolve any difficulties you might have during launching and masting of your boat as well as for commissioning and maintenance technical checks If necessary he will help you with the administrative process of registering your boat As soon as you become the owner familiarize yourself with the manual supplied with your boat sign and date the receipt acknowledgements below and give or send the last one to your agent Owner s Manual receipt acknowledgement to be kept in your Manual 1 the undersigned Name Address owner of DUFOUR 450 No confirm that have received the Owner s Manual for my DUFOUR 450 and accept its being written in English Dated Signature Detach along dotted line Owner s Manual receipt acknowledgement to be returned to DUFOUR YACHTS 1 Rue Blaise Pascal 17187 PERIGNY CEDEX FRANCE 1 the undersigned Name
18. Ranae 62 18 Engine installation diagram 64 19 Holding tank installation diagram 66 20 Lifting essai 68 21 220V airconditioning installation plan 70 22 SPOWE 08116 210 72 ENGLISH 22 04 2013 Page 28 74 DUFOUR 450 GRAND LARGE Presentation plan 1 Accommodation layout V3 i i A 12 WSS 727 2 ENGLISH 22 04 2013 30 74 DUFOUR 450 GRAND LARGE V4 ENGLISH 22 04 2013 Page 31 74 DUFOUR 450 GRAND LARGE 2 Deck fittings plan Ref Description 1 Twin roller stemhead fitting 2 Forestay chain plate 3 Mainsail track traveller 4 Windlass 5 Bow pulpit 6 Lifebelt bracket 7 Telescopic bathing ladder 8 Coachroof handrail 9 Single jam cleat 10 Genoa sheet winch 11 Stanchion 12 Stanchion base 13 Toerail 14 Fuel filler deck plate 15 Water deck plate 16 4 way deck organizer 17 5 way deck organizer 18 Single chainplate for mains and lower shrouds 19 Genoa track with traveller 20 Preventer stay chain plate 21 Starboard stern rail 22 Stern Port balcony 23 Mooring cleat 24 Mainsail sheet track 25 Hinged chain plate 26 Dual ratchet block 27 Halyard winch 28 Crank handle holder 29 Genoa return pulley
19. Your boat is delivered without a boat shore power supply cable or shore connection plug The cable used must be designed for exterior use Its cross sectional area must be appropriate for its length and the rating of the main circuit breaker see electrical diagram The plug must be suitable for the socket on the shore if necessary seek the advice of a professional It should be as close as possible to the IP 67 IEC529 type e Switch off the shore supply at the on board isolator before connecting or disconnecting the shore boat supply cable e Connect the shore boat supply cable at the boat end before connecting it to the shore outlet e Disconnect the shore boat supply cable at the shore outlet before disconnecting it at the boat end e Close the shore outlet cover properly Never e Make modifications to the shore supply cable you must only use compatible connectors e Go swimming close to a boat connected to a shore supply socket danger of electrocution Location of the 220 V master circuit breaker by the chart table Have the system inspected at least every two years During haul out maintenance set to the on position in order to have earth grounding protection via the shore socket ENGLISH 22 04 2013 13 74 DUFOUR 450 Grand Large IV GAS INSTALLATION Operating advice Read carefully all instructions for the cooker and regulator before use or maintenance Ensure that the gas cylinder and regulator are in ac
20. al current C B Power generator Option ENGLISH 22 04 2013 Page 40 74 DUFOUR 450 GRAND LARGE 7 Fuse location diagram Ref Description A ZoneA 12V 250A blade fuse bow thruster ZoneB 12V 125A blade fuse on board protection 80A blade fuse power generator 3A spade fuse power generator auto start 15A spade fuse auto bilge pump 10A spade fuse bilge fan Single pole 6A C curve circuit breaker rear hatch piston Single pole circuit breaker 100A elec winch port halyard Single pole circuit breaker 100A elec winch starboard halyard Single pole circuit breaker 100A elec winch port Single pole circuit breaker 100A elec winch starboard Genoa C ZoneC 12V 30A spade fuse 12 220V converter 1A spade fuse gas solenoid 10A spade fuse thruster 15A spade fuse freezer 40A spade fuse autopilot 10A spade fuse heating 5A spade fuse windlass Free resetting circuit breaker type C 16A WC x2 Free resetting circuit breaker type C 100A windlass Free resetting circuit breaker type C 63A desalinator Zone 220 Ph N circuit breaker 10A dishwasher 16A 30mA residual current circuit breaker airconditioning 10A D curve 2 pole circuit breaker fore aircon 10A D curve 2 pole circuit breaker aft aircon 16A D curve 2 pole circuit breaker saloon aircon D ZoneD 220V 32A 2 pole circuit breaker sho
21. andle perpendicular to seacock body Open seacock Closed seacock Never interfere with the tightening of the seacocks to the hull In the event of a leak consult a professional e In bad weather or when leaving your boat close all the sanitation system seacocks e Keep seacocks closed when not being used e During wintering clean and rinse the seacocks and skin fittings Inspect the brass accessories slight surface corrosion is normal e In the event of more serious corrosion consult your agent Operation of the sea toilets Open the seawater inlet seacock Open the bowl emptying seacock Set the lever to the FLUSH position Operate the pump To empty the bowl and avoid any water slopping when heeling set the lever to the DRY BOWL position Operate the pump until the bowl is dry Repeat these flushing bowl draining operations as many times as is necessary to ensure complete emptying of the pipes When toilets are not being used set the lever to the DRY BOWL position or the CLEF KEY position for certain models Close seacocks after use as the toilet is below the waterline Change the toilet seals regularly Holding tank operation ATTENTION Where a holding tank is fitted take care to lock the evacuation tank to avoid any accidental discharge during wintering The
22. as standard with an emergency tiller and as option with a dual wheel with a system of rudder cables and chains Checks to be carried out periodically Check the play in the various elements rudder stock bearings tension and wear in mechanical components and grease the sprocket and chain if necessary In the event of any doubt or problem consult your agent ENGLISH 22 04 2013 21 74 DUFOUR 450 Grand Large Emergency tiller To use it Unscrew the deck plate to reveal the head of the rudder stock Fit the tiller onto the head of the rudder stock SAILING ENGLISH 22 04 2013 22 74 DUFOUR 450 Grand Large LIGHTNING PROTECTION Your boat is protected against lightning The rigging is electrically grounded Nonetheless for your safety it is necessary to respect certain precautions Maintenance If the vessel has been hit by lightning The protection installation must be inspected to detect physical damage and check the integrity of the device as well as the continuity of the grounding protection The compasses electrical and electronic devices must be examined in order to ascertain if damage or calibration changes have occurred Protection of persons during a storm XIII ENVIRONMENTAL PROTECTION amp SAFETY We recommend you to find out about local regulations concerning respect for the environment and to obey international regulations against pollution in the marine environment MARPOL together with
23. cordance with the requirements of the cooker flow rate pressure type of gas and with the regulations in force in the country where it is being used Make sure the appliance gas taps are closed before opening the valve on the cylinder WARNING e Fuel burning naked flame appliances use up the oxygen in the cabin and release combustion products inside the vessel Proper ventilation is necessary open the designated vents while these appliances are being used e Never block the ventilation openings and check that appliances with flues are working properly e Do not use the cooker oven as a means of heating Do not obstruct quick access to the elements of the gas installation cylinder locker shut off valve The gas cylinder must always be stowed in the sealed ventilated space provided The same applies to spare or empty cylinders Keep close to hand the protective mechanisms lids or caps No other equipment must be stowed in this space Never leave the boat unattended when gas appliances are on Close all valves in the circuit when the boat is left empty shut off valve regulator valve even if the cylinder is believed to be empty In the case of the latter disconnect the valves After the boat has been shut up never smoke when going below and ensure that there is no smell of gas f you smell gas close the circuit valves and the cooker taps ventilate the boat and find the leak before using the installatio
24. cy shall lapse after two years from the date of handover of the goods Article 1641 of the Civil Code The seller is obliged to guarantee against latent defects in the article sold which render it unfit for its intended use or which adversely affect this use to such an extent that the buyer would not have purchased it or would have only paid a lower price if he had known about them Article 1648 Para 1 of the Civil Code Actions arising out of redhibitory defects must be brought by the purchaser within two years of discovery of the defect DUFOUR 450 Grand Large DUFOUR YACHTS TRANSFER OF OWNERSHIP CERTIFICATE TRANSFER OF OWNERSHIP Mod le du bateau Boat N de coque _ _ De Adresse 55 Ville We Date d achat A P A ETE VENDU C P aS Ville E TEL Date d achat Pc en E Le vendeur L acheteur DUFOUR YACHTS Exemplaire retourner dans les 15 jours suivant la transaction S AV DUFOUR YACHTS 11 rue Blaise Pascal 17187 PERIGNY CEDEX FRANCE ENGLISH 22 04 2013 Page 27 74 DUFOUR 450 GRAND LARGE DRAWINGS Presentation DIAN
25. e following specifications a b Minimum capacity per extinguisher 5A 34B Minimum combined extinguisher capacity 10A 68B As per the ISO WD 9094 2 standards 1 extinguisher within 1 m for boats 10 m or 2 m for boats 10 m of the cockpit 2m of the extinguisher opening for dowsing the engine 1 extinguisher within 2 m of the cooker 1 extinguisher within 5 m of the bunks CO2 extinguishers may be placed in accommodation areas only where flammable liquids are present e g galley or where there is powered electrical equipment There must not be more than one CO2 extinguisher per area at risk and its maximum capacity must not exceed 2 kg Only compatible replacement parts must be used in fire protection systems They must bear the same markings and be technically equivalent In addition a fire blanket should be stored close to the galley very useful particularly in the event of a pan fire involving oil ENGLISH 22 04 2013 18 74 DUFOUR 450 Grand Large Safety instructions Vill ENGINE Regular maintenance must be carried out in accordance with the engine manufacturer s recommendations Read carefully the engine operating instructions that come with the boat Do not hesitate to consult your agent or a qualified professional In particular follow the instructions for wintering General precautions ENGLISH 22 04 2013 19 74 DUFOUR 450 Grand Large Place the throttle in neutral before starting the engine
26. e to determine the circumstances of the occurrence of the problem and demand any necessary papers Immobilization following problems encountered and or replacement and or repair work whatever the duration does not create entitlement to compensation The owner shall under all circumstances remain liable for parking fees customs duties and other ancillary expenses All repairs and or replacements will be carried out by an authorized DUFOUR YACHTS agent or by a professional duly acting under the Boatbuilder s instructions If the nature of the repairs requires the guarantee repair work to be carried out in DUFOUR YACHTS workshops or in any location other than the place where the Product is located the owner will be liable for the cost of both outward and return transport to the Yacht builder In the event of the boat s needing to be taken out of the water haul out and re launching costs shall be at the owner s expense C WARRANTY TRANSFER The guarantees are afforded to the first purchaser of the boat involved They are only transferable with DUFOUR YACHTS prior written agreement An ownership transfer note is supplied with the Product documents This must be sent to DUFOUR YACHTS within thirty 30 days of the transfer This note must bear the names addresses and telephone numbers of the former owner and the Purchaser the date of sale and the Product s hull number Upon reception DUFOUR YACHTS will confirm the guarant
27. ee expiry dates and specify whether the unit has received the annual inspection that gives entitlement to the continuation of the contractual guarantees ENGLISH 22 04 2013 26 74 Statutory declarations Article L 211 4 of the French Consumer Code The seller is required to supply goods that conform to the contract and to assume liability for discrepancies existing at the moment of handover He shall likewise be liable for discrepancies arising out of the packaging assembly instructions or installation when he is liable for this under the contract or it has been carried out under his responsibility Article L 211 5 of the French Consumer Code In order to conform to the contract the goods must 1 Be suitable for the normally expected use for similar types of goods and where applicable correspond to the description given by the seller and possess the qualities the sellet has presented to the buyer in the form of a sample or model present the qualities that a buyer may reasonably expect with regard to public declarations made by the seller by the producer or by his representative particularly in advertising material or labelling 2 Either present the characteristics defined by joint agreement by the parties or be suitable for any special usage sought by the buyer that the seller has been made aware of and has agreed to Article L 211 12 of the French Consumer Code Actions arising out of a discrepan
28. ers and numbers that begin with FR DUF ENGLISH 22 04 2013 8 74 DUFOUR 450 Grand Large Builder s plate ES DUFOUR YACHTS 11 Rue Blaise PASCAL 17187 PERIGNY Cedex FRANCE Cat gorie de Design A B C D 1010 1212 m kg 2154 2284 C 0607 Design category A Maximum No of persons in A 10 Maximum No of persons in B 10 Maximum No of persons in D 12 e Max recommended load A B 2154 kg Max recommended load C D 2284 kg 0607 Degrees of danger Part of this information is given on the builder s plate attached to the boat A full explanation of this information is given in the chapter that follows Ocean going see 1 1 Recommended byMasirouitd Nofoofnmargatiom iG 2 sea conditions for category for which it was built recommended by the builder including the weight of all persons aboard the provisions and personal effects and of all equipment not included in the light displacement weight of the boat excluding the content of the tanks CE mark indicating that the boat complies with all the requirements of the Directive The sequence of numbers is the Certification institution s code In this case ICNN Institut pour la Certification et la Normalisation dans le Nautisme refer also to Safety Compliance Declaration ENGLISH 22 04 2013 9 74 DUFOUR 450 Grand Large Indicates a
29. et 15 Mainsail sheet block Option Page 36 74 DUFOUR 450 GRAND LARGE DUFOUR 450 GRAND LARGE Page 37 74 ENGLISH 22 04 2013 5 220 V circuit diagram Ref Description CL1 CL2 CL3 Omo 8 5 2 0 0 7 gt a 3 3Q Equipment Shore AC connection Electrical cabinet with master circuit breaker 16 A residual current circuit breaker 700 W air conditioning 1500 W air conditioning 700 air conditioning 220V outlets E Connector F Connector G Connector Power generator Shore cable 220 V Inverter SAS unit Connection box Battery charger Water heater Optional equipment microwave oven Optional equipment dishwasher Desalinator Earthing plate Thruster Fuse3A Auxiliary battery Residual current circuit breaker Residual current circuit breaker Electrical wiring colours light blue green brown black red green yellow white Option ENGLISH 22 04 2013 Page 38 74 DUFOUR 450 GRAND LARGE 9 www 08 4 4 1 ANM LON 6 220 V electrical installation diagram h Description JO 220 V or 110 V outlet Water heater Battery charger Main circuit breaker box Air conditioning Power socket for microwave oven 6 way box with residu
30. exceptional events and or events arising out of an error of seamanship 8 5 Loss of or damage to products occurring after handover do not release the Purchaser from their obligation to pay the price b Used boats and equipment The order form specifies if the boat or equipment is second hand The Purchaser benefits from a contractual guarantee covering hull and engine only running for DUFOUR 450 Grand Large one year from the date of acceptance of the vessel or goods as noted on the acceptance report c In addition to the contractual warranty detailed above the Seller remains liable for discrepancies in the goods and for latent defects under the conditions provided for under Articles 1641 to 1649 of the French Civil Code and the provisions of the Order dated 17 02 2005 where applicable B COMMON WARRANTY CONDITIONS Any claim under these guarantee conditions must be made formally to DUFOUR YACHTS in writing as soon as the defect is discovered and within eight 8 days for claims under the contractual guarantee Any claim will also be required to quote the serial number of the boat concerned and where applicable the part number s of the part s involved in the guarantee claim Furthermore the shall indicate the exact circumstances under which the problem occurred In order to investigate the request DUFOUR YACHTS may ask for any details and appoint at its own expense a survey or or technician of its choic
31. gas cylinder is well ventilated when replacing it ENGLISH 22 04 2013 15 74 DUFOUR 450 Grand Large V DRAIN amp SANITATION SYSTEM Specifications of the drain system Pump type Theoretical flow rate Manual 36 L 45 strokes minute Electric 12V 1920L h Read carefully the operating and maintenance instructions for your boat s bilge pump Pressurized fresh water pump Fresh water is supplied to the sink and washbasins by an electric pump A filter is installed upstream of the pump and must be cleaned regularly Never allow the pump to run if the tank is empty Refill the tank before using the water supply again The tanks can be sterilized using Clonazone tablets available from pharmacies Every year remove the inspection covers and clean them by filling with water containing a bactericidal detergent leave it to act for a few hours then rinse two or three times During wintering fill the tanks up completely to avoid the development of algae or bacteria or if there is a risk of freezing empty the tanks never use anti freeze Hot water is produced by a water heater connected to the engine cooling circuit and the shore electric supply After the water heater has been emptied make sure that the heating element is covered before power is re applied ENGLISH 22 04 2013 16 74 DUFOUR 450 Grand Large Seacocks Seacocks are of the type OPEN position handle in line with seacock body CLOSED position h
32. h the use of all the safety equipment and with emergency safety procedures man overboard recovery towing etc training sessions are regularly organized by sailing schools and clubs It is recommended that all persons wear appropriate buoyancy aids life jackets personal flotation devices when on deck It should be noted that in certain countries it is compulsory to wear a buoyancy aid complying with national regulations at all times KEEP THIS MANUAL IN A SAFE PLACE AND PASS IT ON TO THE NEW OWNER IF YOU SELL THE BOAT WARNING Our boats are regularly improved in the light of our customers experiences and researched by the shipyard and so the specifications given in this Owner s Manual are not contractually binding and may be changed without notice and without any obligation to update This manual is intended to cover as much information as possible so certain equipment or paragraphs might not apply to your boat In case of doubt please refer to the inventory which should have been given to you by your agent when you placed your order ENGLISH 22 04 2013 7 74 DUFOUR 450 Grand Large GENERAL INFORMATION Design category Your DUFOUR 450 comes under the OCEAN GOING design category A Under conditions of normal use your boat is designed to sail in waves with a significant height exceeding 4 m and winds of force 8 or above on the Beaufort scale and to withstand the severest conditions This sailing capability is equally depende
33. he maintenance and correct charging of the batteries ATTENTION e When installing new electrical appliances take care that the overall consumption of these appliances remains within the capacity of your batteries e Always disconnect the negative battery terminal before the positive terminal e Never allow a conductive object tools etc to bridge across the two battery terminals e When handling batteries keep them horizontal to avoid spillage of electrolyte Wear gloves and protective clothing that will prevent any risk of contact with electrolyte in the event of a leak In the event of electrolyte splashes rinse the affected part of the body copiously and consult a doctor Electric windlass ATTENTION It is essential to run the engine with the throttle slightly open when using the electric windlass ENGLISH 22 04 2013 12 74 DUFOUR 450 Grand Large 220 110 Volt installation DANGER The on board 220V installation is protected by a circuit breaker and fitted with a residual current device The wiring of additional 220 V on board accessories must be carried out by professionals and the master circuit breaker uprated if necessary Disconnect the boat s power supply when system is not in use Connect the metal cases or housings of installed electrical equipment to the boat s protective conductor green or green yellow wire Use double insulated or earthed electrical appliances DANGER
34. ilot B connector Navigation lights and compass Battery positive Saloon and chart table lights Mooring light Cabin and toilet lights Steaming light Battery negative HIFI 12 V outlet C Connector Engine battery test T1 Fore watertank sensor D1 Aft watertank sensor D2 Fuel gauge transducer G1 Water amp fuel at level 0 Fuel gauge transducer G2 D Connector Deck lights Spares 1 Battery positive Spares 5 Spares 2 Spares 4 Windlass control Battery negative Spares 3 Electrical wiring colours p black red white orange brown blue Option We Not supplied ENGLISH 22 04 2013 Page 48 74 DUFOUR 450 GRAND LARGE 1 n i p NM gii 019 zuu g ub auw 9 9 0 auw EL u guu g u 9 q g h A 9 ub FL 50 191 4 9 28119 4 4 21119 4 96 4 p 4 4 9 1 zulul p 4 p u aU 62 1 2 1 5 2 1 93 553 Ho 019 63 83 20 9 000 t 6 966 UUFUUK 49U GRANU LARGE 4 ENGLISH 44 04 4013
35. ive Sea water hose Seawater filter Anti siphon swan neck Waterlock silencer Exhaust pipe Exhaust outlet Fuel system Fuel filler deck plate Filler hose Fuel tank vent Fuel tank hose 250 L Fuel tank Fuel shut off valve Fuel feed hose Fuel return hose Diesel filter with water separator Anti overflow vent Ventilation Ventilation duct Bilge fan Ventilation grilles Miscellaneous Engine battery Engine controls Control cables Page 64 74 DUFOUR 450 GRAND LARGE 26 28 29 27 9 4 E mi 1 XE E TE E pe ge A Se cH Y RENE 16 4 I 2 1 9 9 7 ge 19 Holding tank installation diagram Ref Description Skin fitting amp seacock 34 50 waste deck plate Skin fitting amp seacock 2 220 056 338 anti odour hose 251 anti odour hose Chromed brass vent Aft 50 L polythene holding tank Forward 50 L polythene holding tank U bend gt JO Option ENGLISH 22 04 2013 Page 66 74 DUFOUR 450 GRAND LARGE D E 7 we 9 yall Le ENGLISH 22 04 2013 67 74 DUFOUR 450 GRAND LARGE 20 Lifting diagram Ref Description v See red triangular marker under deck line Light displacement 10275 kg Max beam 4 34 m Standard
36. me with your boat along with the instructions for wintering In the absence of other instructions proceed as follows Close the engine water intake seacock Disconnect the pipe from the engine water intake seacock Drain the seawater circuit Place the pipe into a drum of 25 anti freeze coolant Run the engine until the fluid comes out of the exhaust Atthe end of this operation re connect the pipe to the seacock Attach a notice to the electrical panel and the battery isolator to the effect that the engine water intake seacock is closed IX FUEL INSTALLATION In the event of deterioration flexible fuel pipes must be replaced by pipes bearing the same markings Do the same for all fuel lines ATTENTION e Depending on the trim and loading of your boat the whole of the nominal fuel capacity may not be usable Always maintain a 2095 reserve for safety e Avoid contact between flammable materials and hot parts of the engine e Clear up any fuel overflows in the boat when filling the tanks Never e Store flammable materials in unventilated spaces e Smoke while filling tanks e Obstruct ventilation openings vents engine ventilation grilles ensure that they are kept Clear e Modify the installation unless this is carried out by a technician qualified in this field STEERING SYSTEM The steering system plays a vital role in the safety and comfort of your boat Helm The DUFOUR 450 is fitted
37. n again WARNING In the event of an emergency the circuit valves must be closed immediately ATTENTION Certain precautions must be taken to avoid any contact with naked flames or other hot areas ENGLISH 22 04 2013 14 74 DUFOUR 450 Grand Large Checking the system Check the LPG installation for leaks before use Check the seals for all connections as follows close valves on all devices open gas cylinder valve allow gauge pressure to stabilize close gas cylinder valve observe pressure gauge value for 3 minutes if it drops there must be a leak do not use devices search for leaks using a leak detection device or using soapy water cylinder valve open other valves closed or any other foaming solution as per standard EN14291 have leaks repaired before using installation again repairs and modifications to the circuit should be carried out by a competent person DANGER Never use a flame to look for leaks Flexible hoses must be checked regularly at least once a year replaced if the expiry date marked on the hose is passed replaced five years after the date of manufacture that may be marked on them replaced in the event of damage Changing the gas cylinder DANGER e Close the cooker valves and those on the front of the cooker before changing the gas cylinder e Do not smoke nor use a naked light during replacement of the gas cylinder e Ensure that the compartment housing the
38. nt on the skills of the crew their physical capacities the maintenance of the boat and its equipment So always take care before putting to sea DUFOUR YACHTS is not able to guarantee perfect functioning of the boat in exceptional sea conditions violent storms hurricanes cyclones waterspouts etc SUMMARY OF DESIGN CATEGORIES Design Wind strength s dnimcant Wave Type of sailing Beaufort Wind speed height to be taken g into account A Ocean going Greater than 8 Up to 28 m s Higher than 4 m Up to and Up to and including B Open sea including 8 Up to 21m s dim Up to and Up to and including C Inshore including 6 Up to 17 m s 2m Up to and Up to and including D Sheltered waters including 4 Up to 13 m s 05m Check weather information before putting to sea Take to the sea don t take risks In port every day the Harbor Master s Office posts weather bulletins and forecasts for the next few days M t o France on 0836 68 08 08 Navifax direct on 0836 70 18 52 VHF CROSS transmit several bulletins per day preceded by an announcement on Channel 16 Certification DUFOUR YACHTS has chosen the Institut pour la Certification et la Normalisation dans le Nautisme as the notified body for verifying that your boat complies with European directive CE 94 25 as per module B Identification The hull identification number is located on starboard side of transom It contains a series of lett
39. on panel diagram ENGLISH 22 04 2013 3 Ref Description Protection 12 V distribution panel Deck light Spares 1 Miscellaneous 2 Windlass control Water pump unit Bilge pump Shower drain pumps Navigation lights Mooring light Steaming light Refrigerator Navigation instrument pack Auto pilot Saloon lights Cabin lighting HiFi 12 V outlet 10A 10A 10A 10A 15A 10A 10A 10A 10A 10A 10A 20A 15A 15A 10A Page 46 74 DUFOUR 450 GRAND LARGE 513 17 ZL 2d HH SIHON SMY SIHT 3MMV2 7123 103d 0 3 LIN 39044 IHON DNWIVALS 27 3 51 MOLLYSIAVN 30 GEI 5 234026100 20 0 aiid 239 9 30 3dWOd 55 16 SSW 12 2534 5 0 1 52 5 LH9f1230 1 zh UBI e 30 NH DUFOUR 450 GRAND LARGE Page 47 74 ENGLISH 22 04 2013 10 Electrical panel terminal diagram Ref Description A 1 2 5 N N AW 1 2 3 4 9 10 11 12 Cc OND FW 5 5 Connector Water pump unit Battery positive Fridge thermostat relay Bilge pump Navigation equipmen Shower drain pumps Battery negative Autop
40. pancies between the goods and the contract and for redhibitory defects under the conditions provided for under Articles 1641 to 1649 of the French Civil Code see 8 1 1 8 2 Visible defects acceptance by the Purchaser releases the Seller from their obligation in respect of discrepancies and visible defects 8 3 Contractual guarantee Except for guarantee or penalty clauses expressly agreed at the time of accepting the order the Seller s guar antee is granted under the following conditions The Purchaser benefits from a contractual warranty running for two years from the date of acceptance of the vessel as noted on the acceptance report This is limited to the replacement or free repair at the yacht builders discretion of parts acknow ledged as being defective by the yacht builder s technical services this being without any other com pens ation of any kind For components and accessories visibly bearing the mark of another supplier the warranty is limited to the warranty offered by that supplier It is stipulated that any handling transport parking ENGLISH 22 04 2013 25 74 or convoying costs incurred in carrying out these operations remain the sole liability of the buyer user unless DUFOUR YACHTS yacht builders offer to waive them in full or in part boatbuilder s warranty excludes the cost of transporting the boat or any parts and any consequences thereof together with expense
41. provided by haul outs to inspect the propeller rudder skin fittings and transducers ATTENTION Aft lifting point is located near the sail drive ENGLISH 22 04 2013 24 74 DUFOUR 450 Grand Large XVI GUARANTEE TRANSFER OF OWNERSHIP A CONTRACTUAL WARRANTIES Note This guarantee does not apply to boats being used for commercial purposes it being specified that any hiring or chartering activity falls into this category nor to sailing boats taking part in competitions which may be covered by special guarantees 8 Warranties a New boats and equipment 8 1 1 For both Commercial Purchasers and private consumers domiciled outside the territory of the European Union the Seller is required to furnish the statutory warranties defined in the context of the sale of vessels by Articles 1641 and 1648 of the French Civil Code and in the context of a marine construction contract by Articles 7 and 8 of Act No 67 5 dated 3rd January 1967 pertaining to vessels 8 1 2 For Purchasers domiciled within the territory of the European Union and taking out the contract as private consumers the Seller is required to furnish the guarantees as defined in the context of a boat sales contract by Articles 7 and 8 of the Act dated 7 1 1967 pertaining to vessels and in the context of the Order 2005 136 dated 17 2 2005 and incorporated into the French Consumer Code Independently of this guarantee the Seller remains liable for discre
42. re general protection 32A residual current circuit breaker power generator general protection W Winches zone spade fuse port halyard 5A spade fuse starboard halyard winch spade fuse port Genoa winch 5A spade fuse starboard Genoa winch Option ENGLISH 22 04 2013 Page 42 74 DUFOUR 450 GRAND LARGE ENGLISH 4 30 306 4 UUFUUK 49U 8 Charging amp power circuit diagram Ref Description Windlass Windlass remote control Windlass remote control relay Fuse 15A Battery charger 12 V distribution panel Windlass single pole 100 A circuit breaker Auxiliary batteries 2 as std 2 as option Fuse 125 A auxiliary House batteries switch Fuse 5A Alternator Splitter Starter motor Engine battery Engine battery isolator Windlass relay Bilge fan relay Fuse 5A Bilge fan Fuse 6 ve terminal electrical panel ve terminal electrical panel Battery test Panel for auto bilge pump option ve terminal technical area ve terminal technical area gt gt Option ENGLISH 22 04 2013 Page 44 74 DUFOUR 450 GRAND LARGE ENGLISH 22 04 2013 Page 45 74 DUFOUR 450 GRAND LARGE 9 12 V distributi
43. s and or any damage arising out of the inability to use the boat and or the equipment normal wear and tear cracking crazing or discolouration of the gelcoat damaging resulting from o unforeseeable circumstances or force majeure conversions and modifications repairs even partial carried out other than in workshops authorized by the manufacturer failure to observe the maintenance recommendations set out in the Owner s Manual supplied with the boat o improper use in particular through negligence carelessness abuse or abnormal usage o participating in competitions o negligence in respect of essential protective measures o unsuitable storage conditions transport In order to benefit from the boatbuilder s contractual warranty each time they make a claim under it the buyer user shall be required to submit the boat delivery certificate and the warranty document duly completed and on pain of rendering it void shall notify their dealer vendor of the fault or defect in writing in detail and with justifications within 15 days of its being discovered 8 4 the guarantee covers usage at sea in wind and sea conditions acceptable for safety and in accordance with the vessel s approval category Under these conditions it cannot under any circumstances cover events arising during or resulting from collisions groundings breaking Seas tidal waves cyclones severe storms and all other
44. s or waves these are dangerous conditions in which only an experienced trained crew in good condition sailing a properly maintained boat can sail in a satisfactory manner This Owner s Manual is not a detailed maintenance or repair guide In the event of problems consult the boatbuilder or the boatbuilder s representative If a maintenance manual is provided be sure to use it Always employ the services of an experienced professional for maintenance fitting accessories or modifications Modifications that could affect the characteristics of the boat must be assessed carried out and documented by qualified personnel The boatbuilder cannot be held responsible for modifications made without their approval In certain countries a skipper s licence or authorization is required or special regulations are in force Always maintain your boat correctly and make allowance for deterioration due to age or resulting where applicable from heavy or unsuitable use Any boat however sturdy it is can be severely damaged if it is used incorrectly This is incompatible with safe sailing Always suit your speed and heading to the prevailing sea conditions If your boat is equipped with a life raft read its instruction manual carefully The crew must have on board all the safety equipment life jackets harnesses etc corresponding to the type of boat weather conditions etc In some countries this equipment is mandatory The crew must be familiarized wit
45. sewage tanks 50 optional extra 50 operate using the toilet hand pump The contents of the toilet bowl are discharged straight into the holding tank Periodically check that the vent is working properly A deck plate is provided for emptying the tank The discharge valve can be sealed in the closed position Once a season arrange to clean out the tank using a biodegradable disinfectant chemical Leave the system empty if the vessel is to be left in below freezing temperatures ENGLISH 22 04 2013 17 74 DUFOUR 450 Grand Large VI FLOODING To avoid the risks of the boat flooding Before putting to sea always check that portholes deck hatches and any other openings that could allow flooding are shut When sailing close all seacocks when they are not being used except the engine water intake Do not exceed the recommended maximum load Periodically check the seals of skin fittings seacocks and pipes proper emptying of the cockpit drains the seals of cable glands and sail drive gaskets WARNING Cockpit locker lids must be fastened shut before putting to sea This is particularly important for those lockers that represent a major flooding risk FIRE PROTECTION Installation Fire extinguishers are subject to national regulations and for this reason they are not supplied with your boat We recommend you to equip your boat with fire extinguishers meeting the ISO 9094 1 standard with th
Download Pdf Manuals
Related Search
Related Contents
Bilan de campagne tournesol 2010 Dyson AM09 Hot + Cool Fan Heater White / Nickel 302427 AAC Design-INV 14000 A - PTC Milwaukee 2347-XL Use and Care Manual Emissions - Peterbilt PRESENTATION DE L` INSTITUTION Powermate PW0551750 User's Manual Handy Hints For Easy Home Maintenance Panasonic CU-2E18NBU-1 Installation Manual Copyright © All rights reserved.
Failed to retrieve file