Home
Lockwood Wireless Digital Deadbolt User Guide
Contents
1. Escutcheon Escutcheon with Gasket Batteries back of Inside Escutcheon Strike Plate S D g SS KR Ce 2 Through 3 Inside Escutcheon ied 4 Bolt amp Strike Plate bolts Mounting screws Keys Network Module Mounting Screws Optional Tools Needed Door Preparation Lock Installation e 54mm hole saw e 2 Phillips screwdriver e 25 4mm spade bit e 2 5mm drill bit e Chisel amp hammer COCKLIDOD ASSA ABLOY Prepare lock for installation Unpack the Lock The lock is packed representative of how it will install on the door Before installing the lock on the door A Inside escutcheon 1 Loosen the screw Phillips 2 holding the battery cover The screw remains attached to battery cover 2 Slide the battery cover up and out note the two tabs at bottom of battery cover 3 Remove the inside mounting plate with gasket from the back door side of the inside escutcheon Battery Cover Inside Escutcheon A Ensure that gasket on both Outside N Escutcheon and Inside Mounting x Plate Figure 3A is properly fitted C Q Use either Rubber gaskets for i doors 37 50mm thick or Plastic ty gaskets for doors 32mm 36mm thick Inside Escutcheon amp Mounting Plate with gasket Figure 3A B Bolt NOTE Bolt ships with backset in 60mm position If required press small black button on underside of bolt and pull to extend
2. Lockwood Wireless Digital Deadbolt CHD ASSA ABLOY Table of Contents Warnings Introduction Installation Components and Tools 5 Prepare Lock for Installation 6 Install Lock 7 Programming Programming Features Menu Keys Definitions 9 Components and Tools 10 Definitions 10 Operation 11 Feature Programming Through Menu Mode Using Master PIN code 13 Miscellaneous Information Pairing with Z Wave ZigBee Controllers 14 Hardware Troubleshooting 16 Programming Troubleshooting 17 Reset Lock to Factory Default 18 Installing the Network Module 19 PIN Code Management Sample Sheet 20 Replace install Cylinder 21 COCKLIDOD ASSA ABLOY WARNING Changes or modifications to this device not expressly approved by ASSA ABLOY could void the user s authority to operate the equipment CAUTION Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment IMPORTANT The accuracy of the door preparation is critical for the proper functioning and security of this product Misalignment can cause premature wear and a lessening of security The Lockwood Digital Deadbolt should only be serviced by a qualified technician Finish Care This lockset is designed to provide the highest standard of product quality and performance Care should be taken to ensure a long lasting finish Whe
3. plastic cable p n guide a o Cable Hook a SE i d Cable Guide Harness Clip F D NII 16 COCKLIDOD oo 17 ASSA ABLOY Programming Troubleshooting Symptom Suggested Action Lock does not respond door is open and accessible e Press each keypad button to see if they respond when pressed e Check batteries are installed and oriented correctly in the battery case e Check batteries are in good condition replace batteries if discharged e Check to see if cable is fully connected and not pinched Lock does not respond door is locked and inaccessible e Lock may be in Privacy mode set from inside room Key will grant access e Batteries may be completely discharged e Use mechanical key to gain entry and replace batteries Unit chimes to indicate code acceptance but the door will not open Check to see if there is another locking device on the door e Check the door gaps for any foreign objects between door and frame e Check that the cable is firmly connected to the PC board Unit operates to allow access but will not automatically re lock Check to see if Auto Re lock Mode is enabled Disable Auto Re lock Mode to lock the door automatically e If low battery indicator is lit see below change batteries PIN codes will not register The Master PIN code must be registered prior to adding user codes PIN codes must consist of 4 to 8 digits to regis
4. your hand or fingers to activate Step 2 Press the key Lock Response Register Master Code press the key to continue Step 3 Press the key Lock Response Enter a 4 to 8 digit PIN code followed by the pound key Step 4 Enter a new 4 8 digit Master PIN code followed by the key Lock visually confirms PIN code selection announces Registered This initial step must be performed upon installation or after resetting the lock to factory default Programming and subsequent use of the lock is not possible until this step has been successfully completed SSS Sass bess Touch screen with the back ri Press the key followed Enter the new Master PIN code 4 8 of g hand or fingers to by the 3 key digits followed by the key activate TN PIN code structure Maximum number of user codes is 250 with Network Module without Network Module maximum is 25 user codes 11 12 LOCKUUODD oS ASSA ABLOY Set Up User Codes O User PIN Codes can only be programmed through the Master PIN Code 1 Touch the screen with the back of your hand or fingers to activate 2 Enter a 4 8 digit Master PIN code followed by the key Lock response Menu mode enter number press the 73 key to continue 3 Enter 2 followed by the key 4 Enter 1 followed by the key 5 Enter the User Number to be registered 1 25 followed by the key 6 Enter a 4 8 digit PIN code for the User numb
5. e global leader in door opening solutions dedicated to satisfying end user needs for security safety and convenience ASSA ABLOY Australia Pty Ltd 235 Huntingdale Road Oakleigh Victoria 3166 Australia info au assaabloy com assaabloy com au Lockwood is the leading brand in the Australian locking industry With an established reputation for high quality products this iconic brand provides a wide range of locking solutions to residential housing commercial building and industrial application markets Lockwood is supported by an extensive distribution and after sales support network Our customers include retailers architects trade and industrial personnel locksmiths and security dealers ASSA ABLOY is the global leader in door opening solutions dedicated to satisfying end user needs for security safety and convenience ASSA ABLOY is represented in all major regions in both mature and emerging markets with leading positions in Australia Europe and North America As the world s leading lock group ASSA ABLOY offers a more complete product range of door opening solutions than any other company in the market Australia 1300 LOCK UP 1300 562 587 lockweb com au MC02375_ASSA ABLOY Australia Pty Limited ABN 90 086 451 907 2013 AOLE The Ley va
6. er followed by the 3 key 7 To continue adding users press the key 8 Press the J key to complete the process and conclude the programming session NOTE When registering User codes the code must be entered within 20 seconds or the time expires Lock Response Time expired no codes are registered and the process must be re started Master PIN code must be registered before User codes can be added Protect your privacy always shield your PIN code entry en Door with PIN Code UER Touch lock with back Enter PIN code Press the key to of hand or fingers confirm selection to activate LOCKUUODD oo ASSA ABLOY Feature Programming Through Menu Mode Using Master PIN code 1 Enter the 4 8 digit Master PIN code followed by the amp key 2 Enter digit corresponding to the function to be performed followed by the key om 0 gt B a Master PIN Setting B gt M M denotes Master PIN e denotes User Number Uy denotes User PIN PIN codes can be 4 to 8 digits in length The amp key is used to enter or accept an entry and also to end a programming session The 3 key is used either to enter or to continue additional steps in a programming sequence 13 LE Advanced Lock Settings B Default settings in bold This function appears only with RF network module installed User Number UN 1 25 without network m
7. hat the cable lies against the back recessed area of the inside escutcheon Fig 6A Position and bend cable using the harness clips as shown in Fig E 6A to prevent binding when installing the escutcheon over the f E U Route cable as indicated do not cover hole mounting plate 6 Attach cable assembly to the inside escutcheon PC board by E lining up notches on top of cable connector to slots on PCB connector Fig 6B 8 NOTE Connector should be pressed in firmly using thumbs until Figure 6A IN completely seated Proper position is indicated by arrows on PCB as in Fig 6A amp 6B 7 Install inside escutcheon on inside mounting plate Note the i l P horizontal orientation of the tail piece Fig 7 as you insert the inside escutcheon thumbturn should be vertical Figure 6B 8 Install and secure using 3 M4 x 8mm pan head screws through the inside escutcheon into the mounting plate Fig 8 the mechanical operation of the lock by using both thumbturn and the key The movement of the bolt should be smooth and unobstructed If operation is not smooth review the previous steps to ensure proper installation IMPORTANT Before installing the batteries test NOTE The bolt must be i
8. n a retracted unlocked position prior to installing the batteries 9 Insert four 4 AA alkaline batteries The lock will flash beep several times and respond with a vocal prompt When activating the lock for the first time the lock will adjust for proper handing Figure 8 zang NOTE Refer to programming instructions prior to completion of step 10 10 Install battery cover and tighten Phillips head screw COCKLIDOD ASSA ABLOY PROGRAMMING Programming Features Menus Keys Definitions 9 Operation 11 Programming Features Menus Keys Definitions Outside Inside Phillips Head Screw Touchscreen P Key Battery Cover Network Module Slot a Numbers Alkaline Batteries 4 AA Type Status Indicator Low Battery Indicator Lockout Mode Cylinder Thumbturn Privacy Mode Button Speaker Hole Menu and Icons Used in This Guide O Press the indicated number M EN Enter Master PIN code 4 8 digits in length ress the 3 on the keypad to Enter or Accept entry SEN Enter User PIN Can be 4 8 digits in length H Press the Key to enter the Menu mode gg Manage User Codes 1 25 RF Network Controlled 1 250 ress the Key to return to the previous step or menu setting COCKLIDOD ASSA ABLOY Component
9. n cleaning is required use a soft damp cloth Using lacquer thinner caustic soaps abrasive cleaners or polishes could damage the coating and result in tarnishing This lock may not be used on moving doors i e Cars Trains or similar applications The lock is designed for residential and commercial applications only and door sizes between 32 50mm We highly recommend that a secondary entrance is required in the unlikely event of total failure This lock may not be used on fire doors Introduction The Lockwood Wireless Digital Deadbolt Lock combines a robust lockset with a contemporary electronic aesthetic Users benefit from a touch keypad that makes day to day access effortless Up to two hundred and fifty codes can be distributed amongst users to allow a keyless solution for accessing secure doors Lockwood Wireless Digital Deadbolt is engineered for quick and easy installation and fits in place of a standard 54mm bore hole and 25mm latch hole preparation INSTALLATION ASSA ABLOY Components and tools Included in the box e Installation amp Programming Guide e Inside Mounting Plate e Strike Plate e Outside Escutcheon Battery Cover e Screw Pack e 4 AA Alkaline Batteries e Keys e Plastic Gaskets e Inside Escutcheon e Bolt e Rubber Gaskets Parts Illustrations 1 2 3 mw Battery Cover Bolt l Outside Inside Inside Mounting Plate 4 AA Alkaline
10. nstall batteries T Use feature programming step 7 page 13 for enrollment of the Network Module CD Pin Code Management Sample Sheet PIN Code Management up to 20 users Location Door Number User Type User Name PIN Code User Type User Name PIN Code Master User 01 User 11 User 02 User 12 User 03 User 13 User 04 User 14 User 05 User 15 User 06 User 16 User 07 User 17 User 08 User 18 User 09 User 19 User 10 User 20 20 21 LOCKLIDOD ao ASSA ABLOY How to Replace or Install Cylinder 1 Remove cylinder A Remove outside escutcheon from door B Remove rubber gasket C Remove two screws holding plastic guide in place D Remove plastic guide E Remove screw with washer holding cylinder in place visible after plastic guide is removed F Remove cylinder by pulling towards the door side of escutcheon Before installing cylinder please be sure you have correct length tailpiece 2 Install new cylinder A Reverse previous steps for removing cylinder Cylinder tailpiece information L 92mm a 32 36mm thick doors requires the internal and external plastic thin door gasket 37 50mm thick doors requires the internal and external rubber thin door gasket ASSA ABLOY is th
11. odile 1 250 with network module A Register User PIN B Register B gt 6 gt 3 delete EF gt B oag Continue Continue Complete g Complete a Automatic Re lock bg Enable EE p A Inside Indicator Light B Enable HE p am Hey One Touch Locking B Enable E C B Goan Gian GB EJ Language Setting Mode B English Ha All Code Lockout Mode 30 5 EoD Loy Network Module Setting Bg Join the network Esd ej Exit the network B LEJ Handing the Lock B B Volume Setting Ba B TB Performs automatic handling of the lock a Note If the lock is connected to a network controller it is recommended that it is programmed through the centralised interface PC or hand held device to ensure communication between the lock and the controller unit TID FESTEN MISCELLANEOUS Pairing with Z Wave ZigBee Controllers 14 Hardware Troubleshooting 16 Programming Troubleshooting 17 Reset the Lock to Factory Default 18 Installing the Network Module 19 Pin Code Management Sample Sheet 20 How to Replace Install Cylinder 21 Pairing with Z Wave ZigBee Controllers 1 Check that the Lockwood Wireless Digital Deadbolt is not already paired Before pairing the Lockwood Wireless Digital Deadbolt to a new Z Wave ZigBee network controller be sure it is not paired to another controller You can check this by following these sim
12. ple steps A D gt M PIN EAA Network Module Setting H B a Exit the network E If the Lockwood Wireless Digital Deadbolt shows option B as above the Digital Deadbolt has been paired with another Z Wave Zigbee controller and needs to be unpaired 2 Unpairing a Z Wave Zigbee Controller The old Z Wave ZigBee network controller must be set on the unpaired mode Repeat steps A and B above in the Digital Deadbolt to remove it from the old Z Wave ZigBee network The lock will communicate a successful change 14 COCKLIDOD ao 15 ASSA ABLOY 3 Pairing a Z Wave Zigbee Controller Repeat step A The Digital Deadbolt will show the option below GE Join the network E NOTE If the Lockwood Wireless Digital Deadbolt continues showing B Exit the network the Digital Deadbolt is still paired with the controller and steps A and B need to be repeated again This means the Digital Deadbolt is ready to be paired To do that the controller must be set on the paired mode Then the above step 3 needs to be followed in the Lockwood Wireless Digital Deadbolt to include it to the new Z wave ZigBee network NOTE Lockwood Wireless Digital Deadbolt has been tested successfully with some Z Wave ZigBee controllers Please ask your Home Automation Z wave ZigBee controller retail vendor or dealer for more information about integrations with a specific controller LOCKLIDOD ASSA ABLOY Troubleshooti Hardware Troubleshoo
13. s and tools Low Battery Warning All Code Lockout Mode Return to previous step 0 ai MDN g Pore Master PIN Code The Master PIN code is used for programming and for feature settings It must be registered prior to programming the lock The Master code will also operate unlock lock the lock Main Menu selection 1 User PIN Code The User code operates the lock Maximum number of user codes is 250 with network module without the network module maximum is 25 user codes Main Menu selection 2 Volume Mode The volume setting for PIN code verification is set to low by default Otherwise it can be set to High or Silent Main Menu selection 4 Automatic Re lock Time After a successful code entry and the unit unlocks you can set your lock to automatically re lock after a default time of 30 seconds The Automatic Re lock function can be enabled or disabled Main Menu selection 3 1 All Code Lockout Mode This feature is enabled by the Master PIN code When enabled it restricts all User PIN codes except the Master PIN code When the unit is in Lockout mode the red locked padlock will appear on the screen when attempting to enter a PIN code Main Menu Selection 6 Inside Indicator Light Shows active status Locked of lock and can be enable or disabled in the Advanced Lock Settings Main menu selection 3 2 Low Battery When battery power is low the low battery icon will begin flashing If battery power is completely los
14. ser codes including the Master PIN code and returning all programming features to their original default settings see below 1 Remove the batteries and then remove the interior escutcheon to access the reset button 2 The reset button see image at right is located above the PCB cable connector 3 Hold down the reset button for a minimum of 3 seconds and then reinstall the batteries once the batteries are properly installed release the reset button All features should now be returned to factory default Upon reset Master Code Registration is the only option available and must be performed prior to any other programming of the lock See Operation in this manual for programming instructions Inside Escutcheon Factory Default Settings Settings Factory Default Master PIN Code Registration required Automatic Re lock Disabled Inside Indicator Light Disabled Off One Touch Locking Enabled Audio Enabled Low Privacy Mode Disabled Automatic Re lock Time 30 Seconds Wrong Code Entry Limit 5 Times Shutdown Time 60 Seconds The Master PIN code must be registered prior to any other programming of the lock 18 LOCKUUODD oo 19 ASSA ABLOY Installing the Network Module IMPORTANT The batteries must be removed prior to removing and or inserting the network module e Remove battery cover e Remove batteries e Remove and or insert network module e Rei
15. t use the key override One Touch Locking When the latch is retracted touching the keypad will extend the bolt during Automatic Re lock duration or when Automatic Re lock is disabled Privacy Mode Button Pressing and holding the Privacy button found below thumb turn for a duration of four beeps deactivates the keypad and because it is set from the inside provides a secure lock for the convenience of the occupant s Wrong Code Entry Limit After a specified number of unsuccessful attempts at entering a PIN code the unit will shut down and not allow operation With no RF network enabled default is 5 10 with RF network enabled Shutdown time The unit will shutdown for a default of sixty 60 seconds and not allow operation after the wrong code entry limit has been met When the unit is in Shutdown the red locking symbol will be flashing Tamper Alert Audible alarm sounds if attempting to forcibly remove outside lock from door Language Setting Mode Available in English mode only Main Menu selection 5 Network Module Setting With the optional network module installed this setting becomes available through Main Menu option 7 and allows the lock to connect with a network controller Previous While in menu mode pressing the icon above 3 cancels the current operation and returns the user to the previous step COCKLIDOD ASSA ABLOY Register Master PIN Code Before Programming Step 1 Touch the screen with the back of
16. ter The same PIN code cannot be used for multiple users e Registration management of PIN codes is set by the authority of the Master Code Contact the Master user e User codes must be entered within 5 seconds or the process will have to be restarted The star or pound symbol cannot be used as part of the PIN code The unit operates but it makes no sound Set the volume to high or low The unit displays intermittent RED flashes e This is the voice alarm alerting that it is time to replace the batteries Replace all four 4 batteries with new AA Alkaline batteries Upon entering a PIN code and pressing the key the unit responds with a series of beeps and the keypad flashes three times The digits entered were incorrect or incomplete Re enter the correct code followed by the Gg key The unit responds This is the voice alarm alerting that it is time to replace the batteries Replace all four 4 batteries with new AA Alkaline batteries ote When batteries are replaced Network Module locks have a real time clock that will be set through the User Interface it is recommended to verify the correct date and time particularly with locks operating under Daylight Saving Time DST COCKLIDOD oo ASSA ABLOY TO RESET THE LOCK TO FACTORY DEFAULT SEE THE FOLLOWING Reset Lock to Factory Default The following procedure returns the lock to its factory defaults by deleting all u
17. ting Cycle the lock in both the locked and the unlocked positions If problems are found Symptom Suggested Action Door is binding a Check that door and frame are properly aligned and door is free swinging b Check hinges They should not be loose or have excessive wear on knuckles Bolt will not deadlock a Check for sufficient clearance of the bolt within the strike side jamb Correct this by increasing the depth of the pocket for the bolt b Check for misalignment of bolt and or strike which may be preventing bolt from properly entering the strike With the door open extend and retract the bolt if it is smooth check the strike alignment Bolt does not extend or retract smoothly a Bolt and strike are misaligned see above b Check the backset of door relative to adjustments already made to bolt c Verify proper door preparation and re bore holes that are too small or misaligned d Verify keypad cable connector is routed under the bolt see Fig A e Verify bolt is installed correct side up Fig A Figure A Keypad numerics are scrolling Remove interior escutcheon and check to LJ ensure that the wire harness lies flat against Reset the back recessed area and is properly Do routed along the side of the escutcheon and tucked under the plastic cable guide A I _ EJ LH a Wire harness tucks under
18. to 70mm backset position Fig 3B C The outside escutcheon with gasket remains assembled Outside Escutcheon LOCKUUODD ASSA ABLOY Install Lock 1 Install bolt in door NOTE The bolt must be in a retracted unlocked position when installing the lockset Attach with 2 M4 x 25 4mm screws supplied 2 M4225 mm Flat Head Combination Screws 2 Install strike on the door frame making sure to allow for the bolt to be centred in the strike bd 2 M4 x 25 4mm 8 32 x 1 Flat Head Combination Screws 3 Install outside escutcheon mm As you position the outside escutcheon route the cable through 54mm diameter hole Figure 3A A NOTE Cable goes under bolt see Fig 3B mi Figure 3A Figure 3B 4 Holding the outside escutcheon flush to the door positioning the inside mounting plate by first routing the cable and connector through the mounting plate s 1 2 hole then inserting the mounting plate tongue into the bottom slot of the outside escutcheon See Fig 4A Inside of Door 5 Secure both assemblies using 2 M6 x 54mm pan head machine screws Fig 4B making sure that outside escutcheon is vertically aligned Hand tighten until snug Do not over tighten Figure 4A eas Figure 4B LOCKLIDOD ao ASSA ABLOY CAUTION Use care when assembling to ensure t
Download Pdf Manuals
Related Search
Related Contents
DX 351-CT Manuale di istruzioni per l`uso LA CAL NATURAL QUE RESPIRA LX100 e-Manual Bintec-elmeg hybird 130a Copyright © All rights reserved.
Failed to retrieve file