a & m sales, inc. p.o. box 171 chagrin falls, ohio 44022 (440) 708
Contents
1. Break A way Swivel Essential for fiber optic and coaxial cable pulling these swivels have a break load ranging from 150 1 800 pounds 667 8 006 N and are de signed to separate at 10 of their rated break load If the load rating is exceeded the interior break pin fractures the swivel separates and the cable remains undamaged Break pin is easily replaceable Break A way Swivel Dimensions A B C D E F in mm in mm in mm in mm in mm mm 5 8 16 28 7 3 56 90 19 20 23 6 ot 9 Jis 22 38 10 4 5 115 1 00 27 ol 8 3 13 Break A way Swivel 7 8 Swivel 22 mm 7 8 Swivel 22mm 5 8 Swivel 16 mm Part Break Load Part Break Load Part Break Load Number Ibs N Number Ibs N Number Ibs N 8018100 150 667 53703 800 3 560 3017300 00 390 8018300 200 890 8018700 800 3 558 71399 200 390 8018000 250 1 112 8018800 850 3 781 71400 220 979 8017600 300 1 334 8076600 900 4 003 3017400 250 1112 53700 340 1 513 53704 1 000 4 450 71401 290 1 290 8018400 350 1 557 8015700 1 000 4 448 3017800 300 1 334 8075300 400 1 779 8018900 1 100 4 893 71402 340 1 513 53701 450 2 002 53705 1 200 5 340 71403 400 1 780 8015800 450 2 002 8015200 1 200 5 338 71404 420 1 869 8076500 500 2 224 8019100 1 300 5 782 71405 435 1 935 8018500 550 2 446 8074600 1 400 6 227 71406 450 2 002 53702 600 2 670 8076900 1 500 6 672 8016900 450 2 002 8015000 600 2 669 8019200 1 600 70188 500 2225 8018600 650 2 891 801
2. Continued From Last Page 8761415 DUCTSEAL CARRIER FOAM CARRIER Part No Duct O D Part No Duct O D Part No Duct I D Part No Carrier Part No O D 8761250 CABLE GRIP Duct O D 1 00 1 24 25 4 31 5 Part No 8643137 033 03 013 1 25 SDR 11 13 5 8761375 Pack 2 8761416 8761417 8761255 1 50 1 99 38 1 50 5 8643149 033 03 016 1 5 8761380 8761418 8761419 SDR 11 13 5 Pack 3 8761260 1 50 1 99 38 1 50 5 8643149 033 03 016 2 8761385 SDR 11 13 5 Pack 4 8761420 8761421 8761265 2 00 2 49 50 8 63 2 8643155 033 03 017 32mm 8761570 Pack 5 8761543 8761545 8761560 1 25 1 49 31 8 37 8 8643143 033 03 015 8761565 37mm Pack 6 8761536 8761538 8761555 1 25 1 49 31 8 37 8 8643143 033 03 015 8761520 Pack 7 40mm Hydraulic System Requirements Air Compressor Requirements recomended Operational Capacities Distance and Speed Displays Blower Packages 1 2 3 amp 4 Electronic Control System Blower Packages 5 6 7 amp 8 8761530 8761535 Specifications Hydraulic Operating Pressure Hydraulic Circuit Type Required Flow Capacity Pushing Force Pushing Speed Cable Sizes Standard Duct Sizes other sizes available Typical Installation Distances External Power Requirements Display Unit External Power Requirements Automatic Shutdowns Display Unit
3. Model Pulling Grip The Model R is basically the same grip in size and basket construction as the Model OH however it is shorter This grip is em ployed in pulling all types of rope Diameter Breaking Weave E In M In Number Range In Strength Ibs R36LTW 75 875 18 000 Triple 4 36 RAILTW 875 1 25 20 500 Triple 4 36 Heavy Duty Split Grips Heavy Duty Split Grips are specially designed to pull or support wire or cable already in place They are manufactured of Hi Fatigue Aircraft Strand steel cable with abrasive resistant plastic coating Split Grips are closed with plastic coated stainless steel flexible lacing cable _ m LL 22 20 E SE T a atu rm Mr mI I E Cable Approx Part Diameter Breaking Weave E In M In Number Range In Strength Lbs S115SW 75 1 25 15 000 Single 9 14 S120DW 75 1 25 20 000 Double 9 14 S220SW 1 25 1 75 20 000 Single 11 18 S230DW 1 25 1 75 20 000 Double 11 18 S3258W 1 75 2 25 25 000 Single 13 24 S340DW 1 75 2 25 40 000 Double 13 24 SA30SW 2 45 2 19 30 000 Single 15 30 S450DW 2 25 2 75 50 000 Double 15 30 Split Pulling Grips Rod amp Lace Closing A amp M Sales Split Grips both rod and lace closing are designed for all phases of suspension or pulling where neither end of the conductor is available and middle of the run application of the grip is desi
4. 3 3 1 2 amp 4 Heads Seal Off Body Nominal Innerduct Duct Size I D Range Part Description in mm in mm s 8032900 2 Quick Conduit Seal Off 2 51 1 93 2 36 49 60 v 8032905 2 1 2 Quick Conduit Seal Off 2 1 2 63 2 40 2 76 61 70 N 8032910 3 Quick Conduit Seal Off 3 76 2 87 3 31 73 84 s Tin im 2 bus 8032915 3 1 2 Quick Conduit Seal Off 3 1 2 89 3 50 3 75 89 95 vii mr 8032920 4 Quick Conduit Seal Off 4 102 3 54 4 25 90 108 8032925 5 Quick Conduit Seal Off 5 127 4 72 5 37 120 136 8032930 6 Quick Conduit Seal Off 6 152 5 50 6 29 140 160 8032935 8 Quick Conduit Seal Off 8 203 7 83 8 27 199 210 T x Double Seal Off Kit 4 Locks into duct with a turn of the wing nut handle compressing both rubber rings for a better seal Also helps to align the seal off during insertion 15 psi 1 bar maximum Order Seal Off Body Control Valve and Seal Off Heads separately w w Wa 3w b ndi f bel Part Description a7 e 8032906 Double Seal Off Kit E 2 3 3 1 2 amp 4 Heads and Seal Off Body Double Seal Off Heads Nominal Innerduct Duct Size I D Range Part Description in mm in mm 8032940 2 Quick Conduit Seal Off 2 51 1 93 2 36 49 60 8032945 2 1 2 Quick Conduit Seal Off 2 1 2 63 2 40 2 76 61 70 8032950 3 Quick Conduit Seal Off 3 76 287 331 73 84 8032955 3 1 2 Quick Conduit Seal Off 3 1 2 89 3 50 3 75 89 95 8032960 4 Quick Conduit Seal Off
5. 8761525 1500 psi 103 bar maximum Hydraulic Flow 8gpm 30Ilpm maximum 5 gpm 19 lpm minimum Open Center 1 50 1 99 38 1 50 5 8643149 033 03 016 Pneumatic Pressure 150 psi 10 3 bar maximum 100 psi 6 9 bar minimum 175 to375 SCFM 5m3 min 1 1 m3 min 150165 667 maximum 300 ft min 91 m min Maximum 3 8 to 1 1 4 10mm to 32mm 1 1 1 4 1 1 2 and 2 SDR 11 and 13 5 32 37 and 40 mm 4000 12 000 ft 1200 3700 m No External Power Required Digital LCD Display 12 Volts DC At Programmed minimum and maximum speed When cable slipage or stoppage is detected Digital LCD Display Depends on duct geometry air leakage of duct system and couplings and size of duct and cable Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 700 42 a amp m sales inc 171 chagrin falls ohio 44022 440 708 0180 Innerduct Pressure Test Kit Use the Innerduct Pressure Test Kit to test innerduct before setting up the Fiber Optic Cable Blower The duct system must be able to withstand and hold 150 psi 10 3 bar for the Cable Blower to work properly Kit includes Control Valve Assembly Seal Off Heads Pulling Eyes Pulling Grips and a Tool Box Part Description 8761457 Pressure Test Kit for 1 1 1 4 amp 1 1 2 SDR 11 amp 13 5 Innerduct Other Components Available Part Description 8034318 Seal Off Head for 2
6. Reusable Power Pulling Eyes Swivel Head The Swivel Head Power Pulling Eye is a hybrid tool that combines features from standard reusable power pulling eyes and swivels for superior performance A swivel head prevents twisting and binding of the cable as it is installed It eliminates the need for a separate swivel on each pulling eye when installing single cables into individual conduits or multiple cables into a single conduit Each Swivel Head Power Pulling Eye includes a swivel head sleeve nut and plug Max Diameter Max Eye O D Slot Width Slot Depth Pin Dia Pin Center Part Cable Diameter A B C D E Number Size Color in mm in mm in mm in mm in mm in mm 8917755 1750 Yellow 1 526 39 2 50 64 1 00 25 2 80 71 88 22 1 23 31 8917975 1500 kcmil Black 1 412 36 2 38 60 J3 19 1 78 45 63 16 12 18 8917875 1250 Blue 1 289 33 2 25 9d 19 1 78 45 63 16 d2 18 8917175 1000 kcmil Orange 1 152 29 2 06 52 5 19 1 78 45 63 16 12 18 8917275 750 kcmil Brown 998 25 1 75 44 63 16 1 59 40 56 14 78 20 8917375 700 kcmil Gray 964 24 LJ 44 63 16 1 59 40 56 14 78 20 8917475 500 Yellow 813 2 1 44 37 59 15 141 36 44 11 59 15 8917575 350 kcmil White 681 17 1 25 32 56 14 1 34 34 38 10 59 15 8960375 250 Blue 2375 15 1 13 20 38 10 1 06 27 I 8 293 13 8960475 4 0 AWG Green 528 13 1 00 25 38 10 1 06 27 31 8 53 13 8960875 2 0 AWG Black 419 11 1 00 25 38 10 1 06 27 ll 8 53 13 8960575
7. 18 0 5 5 in long 3384200 Manhole Ladder 20 0 6 1 m long 8384000 Manhole Ladder 22 0 6 7 m long Pulling In Irons Set into the walls of the concrete manholes opposite all duct entrances to provide a strong convenient v attachment for pulling in blocks when installing or removing cables Manufactured with 7 8 22 mm diameter steel and hot dip galvanized Part Description 8383000 9 228 mm w retaining plate 8383001 9 228 mm w cross bar amp retaining plate ia m 8383002 9 228 mm w opposing bends y 8381300 12 305mm w retaining plate if 8381301 12 305 mm w cross bar amp retaining plate Sh Hf 8381302 12 305 mm w opposing bends Mounting Hardware Part Description 2063303 Capscrew 1 2 13 x 1 25 grade 5 hot galvanized 12008202 Capscrew 1 2 13 x 1 50 grade 5 hot galvanized 12022003 Capscrew 1 2 13 x 1 75 grade 2 hot galvanized 8384800 Capscrew 1 2 13 x 2 00 grade 5 hot galvanized 2155703 Capscrew 1 2 13 x 2 50 grade 2 hot galvanized 1 2010003 Lockwasher 1 2 hot galvanized 12008303 Flatwasher 1 2 hot galvanized 2125103 Hex Nut 1 2 13 hot galvanized Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 EIN a amp m sales inc p o box 171 chagrin falls ohio 44022 440 708 0180 Expansion Anchor For use in pre drilled holes Plug expands as anchor is driven into it making
8. 8024405 6 500 28 912 Red Blue PE amp PVC Pulling Eyes Available in the following sizes 1 1 4 1 1 2 2 2 1 4 2 1 2 3 4 5 6 7 10 12 amp 14 Pulling Eyes A amp M PE amp PVC Pulling Eyes feature an extremely rigid center rod to prevent bending and a steel tapered lead cone with the same O D as the conduit This design feature protects the outer leading edge of the conduit They also feature split gripping segments with aggressive gripping threads coupled with a steel expander plug that better grips the full range of conduit I D s Installation of the PE amp PVC Pulling Eyes simply requires the leading eye to be tightened The pulling eyes come standard with attachment eyes at both ends for connecting rope or steel lines Pull out strengths generally exceed the tensile capacity of the conduit For thin wall conduit A amp M has an external 1 8 8 steel sleeve that ensures pulling integrity NOTE PE amp PVC Pulling Eyes come with a 90 day limited warranty Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 amp m sales inc p o 171 chagrin falls ohio 44022 440 708 0180 PE amp PVC Pipe Pulling Eye Sleeves On thin wall PE or PVC duct it is recommended that a steel sleeve be used This product will limit the expansion of the pipe as the pulling eye is installed ensuring the best possible grip for the eye Note 1 1
9. 8031850 5 127 5 00 127 8031860 6 152 6 00 152 6031880 8 203 8 00 203 Replacement Cones for Duct Projectile Part Duct Size Max O D Original equipment replacement cones unm n unm 8031805 1 1 4 32 1 25 32 8031803 1 3 8 35 1 37 35 8031806 1 1 2 38 1 50 38 8031804 1 5 8 41 1 62 41 8031819 2 50 2 00 50 8031821 2 1 4 56 2 20 56 8031826 2 1 2 64 2 50 64 8031831 3 76 3 00 76 8031802 3 1 2 89 3 50 89 8031841 4 102 4 00 102 8031801 4 1 4 108 4 25 108 8031847 4 1 2 115 4 51 115 6031851 5 127 5 00 127 8031861 6 132 6 00 152 8031881 8 203 8 00 203 Poly Line Pail Line attaches to the back of a foam carrrier inflatable carrier or line carrier and is used to pull back a rope Packaged in a weather proof reusable plastic bucket with lid Part Break Strength Length Number Ibs N ft m 8561285 200 890 6 500 1981 8561297 450 2 002 2 500 762 Pallet quantities of 48 available Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Dia Number in mm 8090906 5 8 16 8090912 5 8 16 8091103 7 8 22 8091106 7 8 22 8091112 He 22 S es Part Dia Number in mm 8051303 1 4 6 8051305 1 4 6 8051401 3 8 10 8051403 3 8 10 8051405 3 8 10 Pail Opener Easy to use opener works on any 5 gallon pail including Poly Line Pails E j Part 4 Description 8095000 Pail Opener Double Braided Cable Pulling Rope Premium quality rope recommended
10. 8083975 8083980 8083990 8083910 8083911 8083912 8083913 80839 14 8083915 3 4 10 End Fitting Part No 8083260 8083265 8083270 8083275 8083280 8083290 8083210 ft 600 650 700 750 800 900 1000 Length ft 700 750 800 900 1000 Length ft 700 750 800 900 1000 Length ft 600 650 700 750 800 900 1000 Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 RodNo 8082360 8082365 8082370 8082375 8082380 8082390 8082310 45 Cage Replacement RodNo 8086370 8086375 8086380 8086390 8086310 8086311 8086312 8086313 8086314 8086315 Replacement Rod No 8086570 8086575 8086580 8086590 8086510 8086511 8086512 8086513 8086514 8086515 45 Cage Replacement Rod No 8075760 8075765 8075770 8075775 8075780 8075790 8075710 lS Fiberglass Duct Rod Covers A amp M Rodder Covers are made from 100 UV blocking fabric to give the rodder extra 5 protection from the sun s rays They offer complete weather protection from rain snow and ice in temperatures as low as 40 below zero Rodder Covers are velcro removable Rodder Covers are available in four sizes and can be installed without disassembling the rodder cage Best of all there is no need to remove the cover when rodding PartNumber Description 8081216 16 Duct Rodder Cover 8081224 24 Duct Rodder Cover 8081230 30 Duct Rodder Cover 8081250 45 Duct Rodder Cover Duct Rodder Re
11. 028 2 50 2 99 33 000 10 38 1 7 8 TW TE 033 01 029 3 00 3 49 41 000 10 39 1 7 8 033 01 030 3 50 3 99 48 000 10 41 1 7 8 Rotating Eyeis nota swivel It will not turn while under tension but 033 01 031 4 00 4 49 48 000 10 42 1 7 8 it can turn to relieve pulling torque when the tensionis relaxed 033 01 039 4 50 4 99 48 000 10 58 1 7 8 033 01 047 5 00 5 99 48 000 10 60 1 7 8 033 01 045 6 00 6 99 48 000 10 66 1 7 8 Cable Breaking Rotate Multiple Strength Grip Rotating Eye Part Color Diameter Strength E In M In Eye Number Code Range In Lbs A 033 02 016 Dr Green 0 25 0 49 6 800 5 26 7 8 _ 033 02 018 Brown 0 50 0 74 10 000 6 32 1 033 02 020 Lt Blue 0 75 0 99 14 400 6 41 1 le eere 033 02 022 Gold 1 00 1 24 24 600 8 52 T38 033 02 024 Black 1 25 1 49 30 600 8 56 1 5 8 M Mesh length at nominal diameter 033 02 026 Red 1 50 1 74 30 600 9 60 1 7 8 033 02 028 Dark Blue 1 75 1 99 48 000 10 70 1 7 8 Rotating Eye is not a swivel It will not turn while 033 02 066 Yellow 2 00 2 49 48 000 10 50 1 7 8 under tension butit can turn to relieve pulling 033 02 097 Orange 2 50 2 99 48 000 10 52 1 7 8 torque when the tension is relaxed 033 02 1030 Aluminum 3 00 3 49 48 000 10 54 1 7 8 033 02 1031 Lt Green 3 50 3 99 48 000 10 56 1 7 8 Multiple Strength Grip Flexible Eye Cable Breaking Eye Part Color Diameter Strength E In M In Dia Number Code Range In Ibs A 033 02 044 Green 0 25 0 49 6 800 9 26 1 4 033 02 046 B
12. 1 750165 1 500 Ibs FO 100 DLE 6 8 1 1 1 4 750165 1 5001bs Hook Bail Grip The Hook Bail Grip provides sturdy support for suspending wire and for supporting vertical wire runs on poles in shafts elevator shafts and processing towers Used when the cable ends are available Part Number M n E in Grip Size FO 25 DLE 6 d 1 4 3 8 FO 37 DLE 6 6 1 4 1 2 FO 50 DLE 6 6 1 2 5 8 FO 62 DLE 6 T 5 8 3 4 FO 75 DLE 6 T 3 4 1 FO 100 DLE 6 8 1 1 1 4 U Bail Grip The U Bail is especially suited for suspending cable or wire vertically This grip is made of uncoated galvanized aircraft strand steel for long life and safety Working Load 500 Ibs 500 Ibs 600 Ibs 600 Ibs 750 Ibs 750 Ibs Breaking Strength 1 000 Ibs 1 000 Ibs 1 250 lbs 1 250 lbs 1 500 Ibs 1 500 Ibs Part Number FO 25 U FO 37 U FO 50 U FO 62 U FO 75 U FO 100 U u f M n Ein 6 6 6 6 6 6 5 6 6 T T q Grip Size 1 4 3 8 1 4 1 2 1 2 5 8 5 8 3 4 3 4 1 1 1 1 4 Working Load 500 Ibs 500 Ibs 600 Ibs 600 Ibs 750 Ibs 750 Ibs Breaking Strength 1 000 Ibs 1 000 Ibs 1 250 lbs 1 250 lbs 1 500 Ibs 1 500 Ibs Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 EIN a amp m sales inc p o box 171 cha
13. 1 0 AWG Red 373 10 88 22 38 10 1 06 27 ESI 8 53 13 Reusable Power Pulling Eye Kits For cost savings and ease of ordering we have prepared kits for the Clevis Standard and Swivel Head Reusable Power Pulling Eyes Standard Head Kits Part Description 8917020 Kit for 350 to 100 kcmil power pulling eyes with eye ends Includes 3 each of the eyes for 350 to 1000 kcmil cable 8917070 Kit for 1 0 AWG to 250 kcmil power pulling eyes with eye ends Includes 3 each of the eyes for 1 0 AWG to 250 kcmil cable Clevis Head Kits Swivel Head Kits Part Description Part Description 8917010 Kit for 350 to 100 kcmil power pulling eyes with clevis 8917030 Kit for 350 to 100 kcmil power pulling eyes with swivel ends Includes 3 each of the eyes for 350 to 1000 kcmil ends Includes 3 each of the eyes for 350 to 1000 kcmil cable cable 8917060 Kit for 1 0 AWG to 250 kcmil power pulling eyes with 8917080 Kit for 1 0 AWG to 250 kcmil power pulling eyes with clevis ends Includes 3 each of the eyes for 1 0 AWG swivel ends Includes 3 each of the eyes for 1 0 AWG to 250 kcmil cable to 250 kcmil cable Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 a amp m sales inc p o 171 chagrin falls ohio 44022 440 708 0180 CableGlider amp STD Cable Puller The CableGlider STD cable puller offers portability and ease of set up in a completely self contained unit to adapt to
14. 1 50 1 99 16 400 7 25 1 3 8 2 Mesh length 033 01 018 2 00 2 49 27 200 8 26 1 5 8 033 01 019 2 50 2 99 33 000 10 28 1 7 8 033 01 020 3 00 3 49 41 000 10 30 1 7 8 033 01 021 3 50 3 99 48 000 10 32 1 7 8 033 01 1017 4 00 4 49 48 000 10 33 1 7 8 Rotating Eye is not a swivel It will not turn while under tension but it can turn to relieve pulling torque when the tension is relaxed Dual Pull Grip undi ensi ccs cR CRM ee 4 Breaking Part Color Diameter Range In Strength E In Number Conductor Rope Lbs 033 27 1037 Black 0 19 0 37 0 25 0 65 6 500 10 24 0 218 033 27 1038 Green 0 38 0 62 0 50 0 90 14 000 12 36 0 375 033 27 1039 Red 0 63 0 87 0 75 1 10 20 000 13 48 0 437 033 27 1040 Blue 0 88 1 12 1 00 1 50 30 600 15 60 0 500 033 27 1041 Yellow 1 13 1 37 1 25 1 70 46 800 18 76 0 625 033 27 1042 Alum 1 38 1 90 1 50 2 10 66 500 24 89 0 750 Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Copyright 1992 A amp M Sales Inc EN a amp m sales inc p o box 171 chagrin falls ohio 44022 440 708 0180 Cable Approx Rotate K TypeGrip standard Part Diameter Breaking E In M In Eye Number Range In Strength Lbs Dia 033 01 011 0 50 0 61 5 600 5 16 7 8 033 01 012 0 62 0 74 6 800 5 16 7 8 033 01 024 0 75 0 99 9 600 6 32 1 033 01 025 1 00 1 49 16 400 7 33 1 3 8 033 01 026 1 50 1 99 16 400 7 34 1 3 8 033 01 027 2 00 2 49 27 200 9 36 1 5 8 n Alp m eects 033 01
15. 1 Cartridge Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Copyright 1992 A amp M Sales Inc a amp m sales inc 171 chagrin falls ohio 44022 440 708 0180 Replacement Parts for Directional Drilling Swivels D Drill Swivel rebuild kits allow the swivel to be rebuilt by the user if bentonite gets past the seals and damages the bearings Kit includes 4 bearings 2 seals a roll pin a setscrew a grease zerk and instructions Individual replacement clevis pins and clevis pin locking nuts are also available Rebuild Clevis Locking Rebuild Swivel Part No Kit Pin Nut Tool 1 5 8 41mm 8190001 8190104 2250500 2 51mm 8190002 8190114 2250600 2 1 2 64mm 8190003 8190124 2250700 3 76mm 8190004 8190134 2250800 4 102mm 8190008 8190154 2263000 4 5 8 117mm 8190005 8190144 2250900 6 152mm 8190006 8190164 2251000 8190168 8 203 mm 8190009 8190167 2279000 8190188 Break A way Swivels for Directional Drilling Avoid overstressing cable or conduit being pulled in during directional drilling operations The A amp M Break Away Swivels for directional drilling care designed exclusively to provide both the swivel and the break link for product pull back Eliminate the use of two or more components and shorten the gap between the reamer and pulling eye No need to use weak link pipe sections or wire when using the A amp M Break Away Swivel Six different diameter Swivels are
16. 12 254 0 500 I2 0 038 23 8 4 875 123 8 3 038 100 8581256 4 410 19 616 0 563 14 3 1 063 27 0 5 563 141 3 4 500 114 8581262 5 510 24 508 0 625 15 9 1 125 28 6 6 313 160 3 5 063 129 8581268 6 615 29 424 0 688 179 1 250 31 8 6 938 176 2 5 500 140 8581278 7 935 223 205 0 781 19 8 1 375 34 9 7 813 198 4 6 250 159 Figure 8 Swing Link For quick connections to winch line or pulling harnesses Note To be used for cable stringing or pulling only Working A B C D Part Size Load Length Width Eye I D Eye I D Number ibs N dbs N in mm in mm in mm in mm 8580825 1 4 6 540 2 402 1 94 49 94 24 38 10 50 13 8580837 3 8 10 900 4 003 2 00 74 1 31 33 50 13 63 16 8580850 1 2 13 1 620 7 206 3 25 83 1 63 41 69 18 a5 19 8580875 3 4 19 3 600 16 013 5 00 127 2 50 64 94 24 1 13 29 8580899 1 25 8 100 36 029 6 50 165 2 29 83 125 32 1 50 38 Multiple Pulling Harness Allows staggered attachment to cable or innerduct when pulling through conduit systems Configuration includes 2 3 4 or 5 way legs Choice of steel cable or chains varies by model 7 Separation Between Lead Ring Leg Working Load Working Load Width Legs Dia Dia Part Per Leg Combined A B C D Number Description Ibs N Ibs N in mm in mm in mm in mm 8549200 3 Way 1 8 3mm Cable 550 2 446 1 600 7 117 2 25 57 14 356 37 10 12 8549230 3 Way 1 4 6mm Cable 1 400 6 227 2 900 12 889 3 00 76 14 346 50 13 25 6 85
17. 3 4 7 JL50 0 50 0 61 1 300 4 1 4 8 1 2 JL62 0 62 0 74 1 950 D 10 JL75 0 75 0 99 2 800 5 3 4 10 JL100 1 00 1 24 3 900 6 1 2 11 1 2 JL KIT of the above grips plus a carrying case Kit Consists Of One 1 Each of the Listed Grips With the Carrying Case Included Heavy Duty Grip amp Swivel Case Case provides a secure place to store grips and swivels Constructed of heavy duty plastic coated canvas with Velcro closures Plastic lined pockets snap shut for swivels Case 1s mildew and water resistant for years of use Grips amp Swivels not included Part Description Case Heavy Duty Grip amp Swivel Case Cable Approx Part Diameter Breaking E In M In Light Duty Grip short Number Range In Strength Lbs 033 03 001 0 50 0 61 2 800 3 11 033 03 002 0 62 0 74 2 800 5 11 033 03 003 0 75 0 99 4 000 6 12 033 03 004 1 00 1 24 5 300 7 13 033 03 005 1 25 1 49 5 300 7 14 033 03 006 1 50 1 74 6 800 8 15 033 03 007 1 75 1 99 6 500 8 17 Mesh length at nominal diameter 033 03 008 2 00 2 49 8 500 9 18 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 e Cable Approx Light Duty Grip Standard Part Diameter Breaking E In M Number Range In Strength Lbs 033 03 010 0 50 0 61 2 800 5 16 033 03 011 0 62 0 74 2 800 5 16 033 03 012 0 75 0 99 4 000 6 20 033 03 013 1 00 1 24 6 800 7 20 033 03 015 1 25 1 49 6 800 7 21 033 03 016 1
18. 376 2 51 625 16 7 175 625 16 W 3 12 000 53 376 2 51 1 00 25 7 79 194 625 16 W 4 15 000 66 720 2 1 4 od 125 231 25 8 94 224 19 8080925 20 000 88 960 2 1 2 64 1 00 25 10 23 260 2 80 71 87 22 1 23 31 HD 3 21 000 93 408 2 51 T3 19 8 75 219 M 19 HD 4 30 000 133 440 2 3 8 60 875 22 10 125 254 875 22 8080930 30 000 133 440 3 76 1 31 33 12 04 306 3 56 90 1 12 28 1 37 35 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 EN a amp m sales inc p o box 171 chagrin falls ohio 44022 440 708 0180 821 Champion Swivels Designed to meet common dimensional specifications the 821 Champion swivels are designed for underground cable pulling applications and can handle all types of utility cable Precision machined from high strength steel Fe CAUTION To be used for cable stringing or pulling only NOTE Swivels are not designed to run around bullwheels Part Working Load A B C D E F Number Ibs N in mm in mm in mm in mm in mm in mm 8210007 1 800 8 006 7 8 22 31 8 3 09 78 84 21 31 8 38 10 70136 2 500 11 120 7 8 22 38 9 5 3 38 85 7 8210012 4 000 17 792 1 1 4 32 59 15 4 52 115 1 22 31 38 10 44 11 70137 5 000 22 240 1 1 4 32 54 14 4 16 104 131 5 400 24 019 7 8 22 ol 8 3 09 78 84 21 31 8 38 10 70138 7 000 31 136 1 3 8 35 2I 14 25 4 59 115 8210014 7
19. 4 1 1 2 and 2 eyes come complete with sleeves Pulling Part Eye Size Length I D O D Number in mm in mm in mm in mm 8220125 2 1 2 64 1 88 48 2 90 74 3 13 80 8220130 3 76 2 25 57 3 53 90 375 95 8220140 4 102 2 56 65 4 54 115 4 75 121 8220150 5 127 3 19 81 5 63 143 5 88 149 8220160 6 152 3 69 94 6 67 169 7 00 178 8220170 7 1 8 178 4 00 102 7 17 182 7 50 191 8220180 8 203 4 31 109 8 67 220 9 00 229 8220110 10 254 4 65 118 10 85 276 11 19 284 Swivel Head Innerduct Pulling Eye The Innerduct Pulling Eye is a hybrid tool that combines features from standard innerduct pulling eyes swivels A swivel head prevents twisting and binding of the innerduct as it is installed It eliminates the need for a separate swivel on each pulling eye when installing single innerducts into individual 3 conduits or multiple innerducts into a single conduit Its short length is an advantage on tight bends compared to using a separate swivel and pulling eye Easily installed using a 1 3 8 deep socket or adjustable wrench DU NOTE To determine correct pulling eye size obtain the actual innerduct inside diameter I D The I D measurement must be greater than dimension A and Smaller than dimension B Innerduct Max O D Hole Dia Slot Width Slot Depth Pin Dia Pin Center Part Nominal Size I D Range C D E F G H Number in mm A B in A B mm in mm in mm in mm in mm in mm in mm 8960712 1_1 1 4 25 32
20. 50 1 99 6 800 8 23 033 03 017 2 00 2 49 8 500 9 25 033 03 018 2 50 2 99 10 600 9 21 033 03 019 3 00 3 49 14 700 10 30 033 03 029 3 50 3 99 14 700 10 32 e Cable Approx T Type Grip Short Part Diameter Breaking E in M in Number Range In Strength Lbs 033 04 1082 0 05 0 61 4 500 8 21 A A mM Ee 033 04 1083 0 62 0 74 5 600 8 24 N 033 04 1084 0 75 0 99 6 800 9 24 Lm m 033 04 1085 1 00 1 49 9 600 9 24 RENEE RE RR SRR RR Ae SQ J 033 04 1086 1 50 1 99 16 400 11 24 E Eye length 033 04 1087 2 00 2 49 18 500 12 24 M Mesh length at nominal 033 04 1088 2 50 2 99 24 500 12 24 033 04 1089 3 00 3 49 24 500 14 24 033 04 1090 3 50 3 99 31 000 14 26 T Type Grip Standard Cable Approx Part Diameter Breaking E in M in Number Range In Strength Lbs vl 7 gt 033 04 1091 0 75 0 99 6 800 9 36 033 04 1092 1 00 1 49 9 600 9 36 033 04 1093 1 50 1 99 16 400 11 36 033 04 1094 2 00 2 49 18 500 12 36 m TN 033 04 1095 2 50 2 99 24 500 12 36 033 04 1096 3 00 3 49 24 500 14 36 033 04 1097 3 50 3 99 31 000 14 40 K Type Grip Short Cable Approx Rotate Part Diameter Breaking E In M In Eye Number Range In Strength Dia 033 01 001 0 50 0 61 5 600 3 11 7 8 033 01 002 0 62 0 74 6 800 3 11 7 8 PEN 033 01 013 0 75 0 99 6 800 6 20 1 033 01 014 1 00 1 24 12 800 7 20 1 3 8 E a a a ETE m a W 033 01 016 1 25 1 49 12 800 7 21 1 3 8 33 01 0017
21. 553 6466 or FAX 888 553 6466 EIN a amp m sales inc p o box 171 chagrin falls ohio 44022 440 708 0180 Cable Approx Slack Grip Closed Mesh Part Diameter Breaking E In Number Range in Strength Ibs 033 08 003 0 75 0 99 2 600 7 12 033 08 004 1 00 1 24 4 000 8 15 u mE 033 08 005 1 25 1 49 5 400 8 16 05060506260606252 lt 033 08 006 1 50 1 74 6 600 9 17 E Eye length 033 08 007 1 75 1 99 10 000 10 18 M Mesh length at nominal diameter 033 08 008 2 00 2 49 11 000 10 19 033 08 009 2 50 2 99 11 000 10 20 033 08 010 3 00 3 49 14 500 I2 21 033 08 011 3 50 3 99 14 500 12 22 Standard Pulling Grips Models A thru J are heavy duty grips manufactured of Hi Fatigue Aircraft Strand continuous weave process with flexible stress relieving pulling eye strands are plastic coated which increases the life of the grip provides a bearing surface on underground pulls and increases the ease and safety of installation and removal for workmen Part Number A18LSW A24LDW B26LTW B32LTW C32LTW C38LTW D38LTW D46LTW E46LTW ES2LTW F52LTW F5S8LTW G58LAW G64LAW H58LAW H64LAW IS8L4W 164L4W J58LDW J64LDW Cable Diameter Range In 15 1 1 4 15 1 1 4 1 1 4 2 1 1 4 2 2 2 3 4 2 2 3 4 2 3 4 3 1 2 2 3 4 3 1 2 3 1 2 4 1 4 3 1 2 4 1 4 4 1 4 4 7 8 4 1 4 4 7 8 4 7 8 5 1 2 4 7 8 5 1 2 5 1 2 6 5 1 2 6 6 6 3 4 6 6 3 4 6 3 4 8 6 3 4 8 Approx Breaking S
22. CableGlider cable pullers are not to be used as a hoist or for lifting supporting or transporting people or loads Part Description 8610620 Floor Mount Frame STD model 8674595 Floor Mount Frame Plus amp HD models Floor Conduit Pole Mount Frame Makes it possible to attach the power pack to the floor steel conduit I beams or a wood pole Usually is used where there is limited access for overhead pulling or pulling from pole risers Floor mounting requires 5 8 or MI 6 fasteners grade 5 or better NOTE 24 610mm diameter maximum pole WARNING CableGlider cable pullers are not to be used as a hoist or for lifting supporting or transporting people or loads rd z Part Description A D 1 8674005 Floor Conduit Pole Mount Frame A STD model H 8674010 Floor Conduit Pole Mount Frame Plus amp HD models Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 EIN a amp m sales inc p o box 171 chagrin falls ohio 44022 440 708 0180 Extension Frame Productivity reaches anew level with the CableGlider Cable Puller Extension Frame Using only afew modular components difficult pulling situations can have easy solutions Ideal for cable pulling in deep manholes where added reach is necessary Also high overhead ducts can be reached without compromising the stability of the cable puller Pull slack with the extension frame when extra reach is not needed It actually adds length to the cond
23. Description 8034319 Innerduct Seal Off Kit 1 1 1 4 1 1 2 amp 2 Heads and Seal Off Body with carrying case 8034320 Innerduct Seal Off Kit 1 1 1 4 1 1 2 amp 2 Heads and Seal Off Body Innerduct Seal Otf SSIES SEES 0 y Air Flow Va Innerduct Universal Seal Off aN ry bay Control Valve Air Hose Coupling Nominal Innerduct Duct Size I D Range Part Description in mm in mm Innerduct Seal Off Heads 8034315 1 Quick Innerduct Seal Off 1 29 93 1 19 24 30 8034316 1 1 4 Quick Innerduct Seal Off 1 1 4 32 1 18 1 44 30 37 8034317 1 1 2 Quick Innerduct Seal Off 1 1 2 38 1 31 1 69 33 43 8034318 2 Quick Innerduct Seal Off 2 51 1 93 2 31 49 59 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Rope Adapter Kit Allows a wider range of rope diameters to be used with the Innerduct and Compressor seal offs Adapters specific for 3 16 5 mm 1 4 6 mm 3 8 10 mm diameter ropes provide optimum seal off performance Part Description 8032181 Adapter Kit for Conduit Seal Offs Conduit Seal Off Locks into duct with a turn of the wing nut handle compressing the rubber ring for a firm seal 15 psi 1 bar maximum Order Seal Off Body Control Valve and Seal Off Heads separately Part Description 8032903 Conduit Seal Off Kit 2 3 3 1 2 amp 4 Heads Seal Off Body with Carrying Case 8032904 Conduit Seal Off Kit 2
24. Job Box Blower Job Box Common Parts Pack Common Parts Pack Cable Pack 1 3 Duct Pack 1 3 e Cable Pack 1 3 eDuct Pack 1 3 Common Parts Packages comes in all blower packages includes Allen Wrench eL arge Case w Foam Insert qt Blowing Lubricant e Ratchet Wrench e Small Case w Foam Insert Capscrew Set 6 8 32 s eSocket 11 16 3 8 drive e Small Divided Case w Parts Label O Ring Seal Kit 5 8 x 600 lb Swivel Parts and User Manual Venturi Air Plug Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 EUN a amp m sales inc p o box 171 chagrin falls ohio 44022 440 708 0180 Component Options Duct Packs amp Cable Packs The Fiber Optic Cable Blower operates efficiently with most common combinations of cable and innerduct sizes The correct size cable seals feed tube and venturi must be determined for the cable being installed Also necessary are the correct size innerduct seals clamps and carrier for the innerduct being occupied Use the chart below to determine the correct size components for your specific cable and innerduct installation project Innerduct Seal Cable Seal Innerduct ssembly Clamp I SL T El Tractor Feed Feed Tube Venturi CABLE PACK VENTURI FEED TUBE CABLE SEAL CABLE GRIP Cable O D Part No Cable O D Part No Cable O D Part No Cable O D Part No Cable O D P
25. Quadrant Block Protects fiber optic cable during installation Pulling radius of 26 660 mm 13 alluminum rollers on bronze bearings allow cable to make a gradual 90 turn for easy pulling through manhole opening Lightweight corrosion resistant aluminum side plates Can be lowered into any manhole opening and chained in place for good allignment or used as a cable guide at street level 2 600 Ibs 1 1 565 N calble tension load capacity 1 1 2 38 mm maximum cable diameter consult cable manufacturer for minimum bend radius Support bar sold separately Replacement Sheaves available Part Description 8539350 Fiber Optic Quadrant Block Hanger Arms Allows the hanging of the fiber optic quadrant block in a manhole for more flexible positioning Part Description 8539320 Hanger Arm Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Fiber Optic Hanger Block 5 aluminum rollers on bronze bearings allow cable to make a gradual 90 turn for easy pulling through manhole opening Has a pulling radius of 12 305 mm Two non metallic keeper rollers to hold the cable in place during the pull Lightweight corrosion resistant aluminum side plates Can be sus pended in the manhole or hung on an overhead pole for easy pulls 3 4 19mm maximum cable diameter consult cable manufacturer for minimum bend radius 800 Ibs 3 558 N cable tension load capacity Replacement She
26. a solid hold in concrete Allowable Working Loads Part Tension Shear Number Description Ibs N Ibs N 8409900 3 4 10 UNC Threads 4 010 17 836 4 400 19 571 8409901 5 8 11 UNC Threads 2 420 10 764 3 050 13 566 8409902 1 2 13 UNC Threads 1 690 7 517 1 560 6 939 Universal Plug For temporarily plugging duct bell ends and terminators These polyethylene plugs come in sizes to fit all types of manufactured duct even when it s bell ended or coupling is attached The universal plugs extended lip design permits easy extraction Part Size Conduit I D Range Number in mm in mm 8047400 2 5 1 20 2 60 30 66 8047500 3 76 2 75 3 65 70 93 8047601 4 102 3 70 4 70 94 119 8047700 5 127 4 80 5 75 122 146 8047800 6 152 5 82 6 80 148 173 8047600 4 102 3 70 4 70 94 119 Fiber Optic Innerduct Plug Split plug with bushing assembly for sealing around cable in duct installations Simple installation around in place cables seal all types of innerduct ideal for manholes buildings and cabinets U S Patent No 4 842 364 Part Size Conduit I D Range Innerduct I D Range Number in mm in mm in mm 8043910 1 25 1 00 1 14 25 29 35 57 9 14 8043911 1 25 1 00 1 06 25 27 50 70 13 18 8043912 1 1 4 32 1 22 1 36 31 35 35 57 9 14 8043913 1 1 4 32 1 22 1 36 31 35 57 70 13 18 8043914 1 1 4 32 1 24 1 34 31 34 70 90 18 23 8043915 1 172 38 1 50 1 65 38 42 35 57 9 14 8043916 11 2 38 1 50 1 65 38 42 50 70 13 18 8043920
27. a variety of pulling situations It comes equipped with a two speed removable power pack providing up to 6 500 pounds 28 912 N of pulling force at low speed Speed changes are no problem with just a turn of a dial Design features include a self tailing capstan for added stability a pivoting arm and a footswitch for operator convenience and safety Accepts all diameter rope self tailing capstan accepts 5 8 16 mm to 7 8 22 mm rope only CableGlider STD includes the following items e Puller Foot switch Retaining Fork e Conduit Adapters 2 51 mm 3 76 mm 3 1 2 89 mm 4 102 mm Tool box for the accessories CableGlider STD Part Number Description 8610650 110 Volt Standard Cable Puller 8678025 220 Volt Standard Cable Puller for export only International orders must specify plug Warning CableGlider cable pullers are not to be used as a hoist or for lifting supporting or transporting people or loads Complete Pulling Packagesfor CableGlider STD Pulling packages offer cost savings and ordering convenience Part Number Description 8674389 CableGlider STD Package 1 sara ae om 110 Volt Puller with accessories above 7 ableGiider Package 4 for export only HD Extension frame e 220 Volt Puller with accessories above e 600 ft 183 m of 7 8 22mm double braid rope a m Floor conduit pole mount frame t 183 m of 7 8 22mm double braid rope e 5
28. amp m sales inc p o box 171 chagrin falls ohio 44022 440 708 0180 3 8 16 End Fitting 30 Cage 5 16 Python Rod Length Replacement Length Replacement Part No 8084320 8084325 8084330 8084335 8084340 8084345 8084350 8084355 Part No 8083820 8083825 8083830 8083835 8083840 8083845 8083850 8083855 8083860 8083865 Part No 8083920 8083925 8083930 8083935 8083940 8083945 8083950 8083955 8083960 8083965 Part No 8083220 8083225 8083230 8083235 8083240 8083245 8083250 8083255 Copyright 1992 A amp M Sales Inc ft 200 250 300 400 500 7 16 Cobra Rod Length ft 200 250 300 400 500 600 7 16 Python Rod Length ft 200 250 300 400 500 600 9 16 Python Rod Length ft 200 250 300 400 500 RodNo 8082320 8082325 8082330 8082335 8082340 8082345 8082350 8082355 Replacement RodNo 8086320 8086325 8086330 8086335 8086340 8086345 8086350 8086355 8086360 8086365 Replacement RodNo 8086520 8086525 8086530 8086535 8086540 8086545 8086550 8086555 8086560 8086565 Replacement Rod No 8075720 8075725 8075730 8075735 8075740 8075745 8075750 8075755 Part No 8084360 8084365 8084370 8084375 8084380 8084390 8084310 3 8 16 End Fitting Part No 8083870 8083875 8083880 8083890 8083810 8083811 8083812 8083813 8083814 8083815 3 8 16 End Fitting Part No 8083970
29. coefficient of friction universal cable jacket compatibility minimal residue and safe clean use The use of American Poly water lubricants is an extremely effec tive way to minimize tension on cable as it is pulled into conduit A number of lubricants are available to meet specialized end user needs A amp M Sales Offers a complete line of Polwater products in every available size from quart sized bottles to 55 gallon drums See below for a list of available products Call toll free for any questions pertaing to your pulling needs Check out the new software available from Polywater It uses commonly accepted pulling equations to estimate cable pulling tension and sidwall pressure around bends Planning cable pulls can save money by minimizing the number of splices vaults hand holds and pulling setups while ensuring pulling tensions that won t damage cable Polywater Products that we offer 1 Polywater Cable Lubricants amp Accessories 2 Polywater Plus Silicone A Type NN B Type WNN C Type NB D Type WNB E Type FS 3 CableFree Loosener for Stuck Cables 4 Type HP Cleaner Degreaser 5 Type KC Contact Cleaner 6 HydraSol Cable Gel Remover 7 Pull Planner II Cable Tension amp Conduit Design Software 8 Ice Free Antifreeze Gel 9 Lube Master Cable Lubricant Applicator 10 LongShot Lubricant Spreaders 11 FlexLite Lubricant Funnel 12 SureGrip Cable Handling Gloves 13 Sandbore Drilling Fluid Additive 14 HydraFoam 2020 Clean
30. e Seal Off Body e Seal Offs for 1 2 13 mm 6 152 mm conduit e Line Carriers for 2 51 mm 3 76mm 4 102 mm ho EM id 5 127 mm amp 6 154mm conduit E Yi ii m M vo io Mr LT Ham Part Description 8030000 110 Volt System with 30 Amp twist plug j de mi et im 8030040 220 Volt System Supplied without a plug 8030001 110 Volt Utility Kit complete with Accessory Bag 8030041 220 Volt Utility Kit complete with Accessory Bag Contractor Power Dart Kit Includes the following items for electrical contractor applications e Blower Unit e 25 8m x 2 1 2 64 mm heavy duty hose eSeal Off Body e Seal Offs for 1 2 13 mm 6 152mm conduit Foam Carriers for 1 2 13mm 3 4 19 mm 1 25mm 1 1 4 32 mm 1 1 2 38 mm 2 51 mm 21 2 64 mm 3 76 mm 3 1 2 59 mm amp 4 102 mm conduit Part Description 8030030 110 Volt System with 30 Amp twist plug 8030050 220 Volt System Supplied without a plug 8030031 110 Volt Utility Kit complete with Accessory Bag 8030051 220 Volt Utility Kit complete with Accessory Bag Replacement Accessories Power Dart Blower Seal Off Seal Off 2 1 2 6 64 152 mm Part Duct Size Number in mm 8039700 1 2 1 1 4 13 32 8066800 1 1 2 2 1 2 38 64 8039500 2 12 6 64 152 Seal Off Body Power Dart Blower Seal Off Body Part Duct Ss Seal Off 1 1 2 2 1 2 38 64 mm Number in mm 8039400 1 2 6 13 152 Powe
31. for cable pulling Complete with spliced eye on each end Double braided construction offers high working loads and tensile strength without kinking Other sizes available Recomended Working Load Length Standard Tensile Minimum Tensile 5 1 12 1 ft m Ibs N Ibs N Ibs N Ibs N 600 183 16 200 72 058 13 500 60 048 2 700 12 010 1 125 5 004 1 200 366 16 200 72 058 13 500 60 048 2 700 12 010 1 125 5 004 300 9 28 000 124 544 25 200 112 090 5 040 22 418 2 100 9 34 600 183 28 000 124 544 25 200 112 090 5 040 22 418 2 100 9 34 1 200 366 28 000 124 544 25 200 112 090 5 040 22 418 2 100 9 34 Polypropylene Rope Yellow Good quality general purpose rope Not recommended for powered pulling applications Other sizes available Contact factory for additional rope specifications Recomended Working Load Length Standard Tensile Minimum Tensile 5 1 12 1 ft m Ibs N Ibs N Ibs N Ibs N 3 000 914 1 250 5 560 1 130 5 026 226 1 005 94 418 5 000 1 524 1 250 5 560 1 130 5 026 226 1 005 94 418 1 200 366 2 700 12 010 2 440 10 853 488 2 171 203 903 3 000 914 2 700 12 010 2 440 10 853 488 2 171 203 903 5 000 1 524 2 700 12 010 2 440 10 853 488 2171 203 903 2 P ee Pulling Tape A flat woven replacement to 1 4 Polypropylene rope that provides a lower coefficient of friction due to its flat woven design Drastically reduces the chance of burn through that is associated with r
32. is installed It consists of two components Mechanical Sensing Unit which mounts directly to the cable puller and Electronic Control Box The unit will accommodate pull tape and rope up to and including 7 8 diameter with an accuracy of 5 of full scale Load handling capabilities and other specifications are determined by the model used Mechanical Sensing Unit Mounts easily to the cable puller frame with a mounting bracket and pin The Running Line Tensiometer s Mechanical Sensing Unit permits rope installation without disassembly of the unit Electronic Control Box Features large LED display and analog display of pulling tension A programable overload setpoint has both an audible and visual indication of an overload condition The Electronic Control Box also has the capability to disengage the cable puller if an overload occurs A chart recorder optional offers a permanent record of the pull Running Line Tensiometer CableGlider STD Measures loads of 0 to 6 500 Ibs O to 28 912 N with an accuracy of 325 165 1 446 N Running Line Tensiometer Package I m Includes the following iterns Mechanical Sensing Unit Electronic Control Box Mounting Hardware Mechanical Sensing Part Description Unit mounted on 8674235 110 Volt RLT fo CableGlider STD CableGlidder STD 8674243 220 Volt RLT for CableGlider STD for export only Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX
33. made to your specifications Illustration shows Flex Eye Grip with 07 A 3 4 11 4 Single Weave 1 A 3 4 11 4 Double Weave B 11 4 2 Triple Weave gg Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466
34. manhole to guide cable into the duct Also used with alignment arm for cable removal Hinged yoke for easy cable installation and removal 10 000 Ibs 44 480 N cable tension load capacity Alignment arm sold separately Replacement sheaves available Part Sheave Size Number in mm To 8041400 3x11 76 x 279 d pe 8042400 4x 11 102 279 sold separately 8042420 4x 20 102 x 508 8042500 5 11 1271x279 8042520 5x20 127 x 508 8042526 5 x 26 1 2 127 x 673 8042527 5 x 26 1 2 127 x 673 w Light Duty Hanger Arm 8082600 6x11 152 x 279 EY Hooked Hanger 8082800 8 11 203 279 Sheave 8045901 Alignment arm for 3 4 amp 5 76 102 amp 127 mm Sheaves Assembly With 26 1 2 Sheave Cable Sheaves GMP These Sheaves are used in placing and removing underground cable Constructed from high strength aluminum alloy and have self lubricating bushings hole sizes are 1 3 8 in diameter to fit a 1 5 16 pin These units are available in 11 20 and 26 1 2 diameters and may be purchased for maximum 3 4 and 5 cables These units are normally used in conjunction with either the GMP Pulling Frames or Cable Sheave Shackles A GMP Sheave Pin is also used to retain the Sheave to either unit Included with the frames or shackles Part Description Sheave Size Root Weight 71723 CableSheave 3 x IT 8 1 2 15 Ibs 71726 CableSheave 4 x 11 7 7 8 20 Ibs 71729 CableSheave 3 x II 6 7 8 25 Ibs 71722 Cable Sh
35. or FAX 888 553 6466 Fiber Optic Cable Puller Trailer Positioning Three built in cable puller An example of the proper way mounts provide a total of to set up the Fiber Optic Cable seven cable pulling positions Puller Trailer for a pull The Remote Mounting Stand detaches from the trailer for more versatility Slip Clutch Capstan Slip Clutch Capstans from A amp M Sales are designed to mount directly on a bayonet style winch drive shaft A factory preset torque limiter prevents pulling tensions from exceeding 600 pounds 2 670 N 10 60 Ibs or 267 N If the preset load is reached the capstan will slip and discontinues rotating High strength aluminum and steel construction ensures product durability and cable protection The capstan is factory calibrated to 600 Ibs 2 269 but can be calibrated to different loads from 300 to 1 000 Ibs 1 334 to 4 448 The capstan is designed for use with a 2 7 16 62 mm diameter AT amp T specification bayonet style power take off PTO shaft Part Description Flat Width Max Cable O D Number in mm in mm in mm 8760030 30 762 4 102 T5 19 Portable Hydraulic Power Pack This portable power source is matched perfectly to the power requirements of the Fiber Optic Cable Puller and the Fiber Optic Cable Blower Power source is a 16 HP 11 9 kW Briggs amp Stratton V Twin Vanguard gas or diesel engine Features electric start large capacity hydraulic cool
36. s The blower features a patented expandable split ring coupled with a tapered expander plug that allows the seal off to work on the full range of ID s fora specific conduit O D e g 4 102 mm schedule 40 telephone TC 6 DB amp EB and TC 8 DB amp EB This feature allows up toa 1 2 13 mm variation in conduit ID with no loss in seal off efficiency The Winch Line Blower System The system is comprised of these mechanical assemblies e Seal off body for specific range of Conduit ID s e Seal disc to prevent blow back Cable insert for abrasion resistant cable travel Carrier for specific range of conduit ID s Control Valve Assembly Air Hose Assembly 25 feet 7 6 m e Job Box Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 EIN a amp m sales inc p o box 171 chagrin falls ohio 44022 440 708 0180 Winch Line Blower Single Conduit Kits Includes all mechanical components and accessories listed on previous page bottom for a specific range of conduit sizes Winch Line blower kits are available for the following conduit sizes 1 5 2 2 5 3 3 5 4 5 6 and 8 PVC Call for a complete listing of Winch Line Blower Kits and help in selecting a kit that will best suit your needs Winch Line Blower Multiple Conduit Kits Combined single kits to make multiple conduit kits Includes all mechanical components and accessories for a full range of conduit
37. sheaves on bronze bearings allow cable to make a gradual 90 turn for easy pulling through manhole opening Pulling radius of 24 25 inches 616 mm Can also be suspended in manhole to provide alignment to duct run 4 800 Ibs 21 350 N cable tension load capacity Support Bar sold separately Replacement Sheaves available Part Size Number in mm 8539000 3 76 8539100 4 102 8539200 5 127 Quadrant Block GMP The Quadrant Block is used to guide the winch line and cable when placing and removing under ground cable Consists of six sheaves supported in an arc of a circle by an aluminum frame to provide a bending radius of 24 inches A sturdy aluminum housing utilizes six cast aluminum sheaves each mounted on a self lubricating bushing Each block is approximately 43 1 2 long There is a hole in each side plate for insertion of a 1 1 4 digging bar parrellel to the ground This is to keep the sheave from falling into the manhole These quadrant blocks are normally used with either the GMP Cable Sheave or Pulling Frame Part Size Number in mm Weight 84453 3 76 60 Ibs 84454 4 102 75 lbs 84455 5 127 90 Ibs Fiber Optic Quadrant Block GMP The Fiber Optic Quadrant Block provides a smoother and safer cable placement in manhole vaults with a minimum of set up time This quadrant block has eleven machined aluminum sheaves that provide better cable support than all other conventional blocks Its corrosion resistant aluminum and stainl
38. sizes These kits are great if you have a need for multiple pulling applications in various sized ducts Part Description 8202300 Multiple conduit kit fo 2 51mm 3 76mm and 4 102mm duct Includes single kits 8202001 8203001 8204001 control valve assembly air hose assembly and job box 8202400 Multiple conduit kit for 2 51mm thru 4 102mm duct Includes single kits 8202001 8202501 8203001 8203501 8204001 control valve assembly air hose assembly and job box 8204600 Multiple conduit kit for 4 102mm thru 6 152mm duct Includes single kits Compressor Seal Offs Universal duct seal off for blowing projectiles and line cariers through the duct using an external air compressor Order Seal Off Body Control Valveand Seal Off Heads separately Universal Seal Off Control Valve The Universcd Seal Off Control Valve Body is used with the Innerduct Seal Off Conduit Seal Off amp Double Seal Off Usethe interchangeable Part Description heads for the style and size you need Comes equipped with an air flow 8032165 Seal Off Control Valve Body valve and a universal hose coupling for attachment to most compressors 3 16 rope adapter included Innerduct Seal Off Kits Inserts into innerduct and twists tight for seal Consists of a common Universal Seal Off Control Valve Body and an assortment of heads to fit duct sizes shown below Order Seal Off Body Control Valve and Seal Off Heads separately Part
39. the pin using a handy built in bearing detente There s even a stop pin built in to each member to keep the shackle from closing completely in either direction Part Description Weight 70045 Fiber Optic Shackle 30 Ibs Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 EIN a amp m sales inc p o box 171 chagrin falls ohio 44022 440 708 0180 Fairlead Quadrant Block Originally designed to install transpacific fiber optic cable these quadrant blocks provide a 60 1 524 mm pulling radius to guide any type of cable 18 machined rollers on bronze bearings 8 203 mm wide by 5 5 140 mm in diameter allow the cable to make a gradual 90 turn for easy cable installation 10 000 Ib 44 480 N capacity Replacement sheaves available A B C Part Description in mm in mm in mm 8094500 Fairlead Quadrant Block 96 2438 36 914 9 229 3 Sheave Cable Guide 3 cast aluminum sheaves on bronze bearings allow a gradual 90 turn for easy pulling through manhole opening Pulling radius of 24 6 1 0 mm the cable guide will sit on manhole edge suspended in manhole or fit the jamb skid 10 000 165 44 480 N cable tension load capacity Support bar sold separately see support bar Replacement Sheaves available Part Size Number in mm 8539600 6 152 8539800 8 203 Note To fit the Jamb Skid the four bolts holding the hook must be removed Mini Corner
40. 00 SDR 11 amp 13 5 Innerduct 8913328 Pulling Eye for 2 00 SDR 11 amp 13 5 Innerduct 8643155 Pulling Grip for 2 00 SDR 11 amp 13 5 Innerduct Innerduct Couplings ETCO Double E Loc Innerduct Couplings are designed to join both smooth and ribbed HDPE innerduct specifically for pneu matic methods of cable placement where air and water tight integrity of the system is imperative and where the joint is unrestrained such as in a vault manhole or hand hole The couplers are pressure tight to internal pressures above 200 psi when restrained or buried and can maintain these pressures unrestrained and are reusable There are no metal parts and can be hand tightened with no special tools Coupling Duct Length Part Nominal Duct O D when tight Number Duct Size Type in mm in mm 8676510 1 IPS Smooth 1 315 33 6 25 159 1 34 O D Ribbed 1 340 34 6 25 159 8676511 1 42 O D Smooth 1 420 36 6 25 159 1 1 8 SIDR 9 Ribbed 1 460 37 6 25 159 8676512 1 50 O D SDR 11 Smooth 1 500 38 6 25 159 8676513 1 1 4 True 1 125 I D Smooth 1 530 39 6 25 159 1 1 4 O D Ribbed 1 575 40 6 25 159 8676514 1 60 O D Smooth 1 000 41 6 25 150 8676515 1 1 4 IPS Smooth 1 660 42 6 25 159 1 1 4 O D Ribbed 1 700 43 6 25 159 8676516 1 1 2 True SIDR 9 Ribbed 1 830 46 8 25 210 8676517 1 1 2 True SIDR 9 Smooth 1 830 46 8 25 210 8676518 1 1 2 IPS Smooth 1 900 48 8 25 210 8676520 92 IPS Smooth 2 375 60 8 50 216 Fiber Optic
41. 00 9 786 8059525 2 1 2 64 2 98 76 2 00 51 2 200 9 786 8059530 3 76 3 50 89 2 37 61 2 200 9 786 m 8059535 3 1 2 80 4 10 104 2 19 70 4 500 20 016 8059540 4 102 4 84 123 3225 83 4 500 20 016 8059550 5 127 5 98 152 4 00 102 4 500 20 016 8059560 6 I52 7 08 180 4 75 121 4 500 20 016 Rubber DuctSwab Ideal for cleaning and assisting in the spreading of lubricant throughout the duct 7 000 Ibs 31 136 N load capacity Body Part Duct Size Length Max O D Number in mm in mm in mm 8028820 2 51 10 254 2 00 51 8028830 3 76 10 254 3 00 76 8028700 3 1 2 80 10 254 3 50 89 8028800 4 102 10 254 4 00 102 8058700 5 127 10 254 5 00 127 2058800 6 152 10 254 6 00 152 4 5001bs 20 016 N load capacity 8022880 8 203 10 254 8 00 203 Leather Washer Duct Cleaner Tough durable leather washers in graduated sizes for cleaning duct prior to cable pulling 4 500 Ibs 20 016 N load capacity Body Part Duct Size Length Number in mm in mm in 8025430 3 76 14 38 365 3 00 8025300 3 1 2 89 14 38 365 3 50 8025400 4 102 14 38 365 4 00 Short Rubber Slug For proving duct integrity and for spreading pony a Duct Size Length Max O D cable pulling lubricant especially in tight radius Number in trii in in tium 8082025 2 1 2 64 3 25 83 2 50 64 8082030 3 76 3 25 83 3 00 76 8082035 3 1 2 89 3 25 83 3 50 89 8082040 4 102 3 25 83 4 00 102 8082050 5 127 3 25 83 5 00 127 8082060 6 152 3 25 8
42. 1 Mu Hydraulic puller mounted on a 2 1 2 64 mm square tube e 30 762 mm diameter capstan Foot Control hydraulic control assembly Hoses and cords to connect the puller Package2 Fiber Optic Cable Puller Contains all items in package 1 plus the electronic tension monitoring system items listed below Puller package does not include a remote mounting stand or a base mount please order separately Part Description 8690025 Fiber Optic Cable Puller Package 2 Electronic control box Battery pack All Items in package 1 Package 3 Fiber Optic Cable Puller Deluxe ordering package includes all items in package 2 plus a chart recorder for permanent documentation of your pull Puller package does not include a remote mounting stand or a base mount please order separately Part Description 8690050 Fiber Optic Cable Puller Package 3 Chart Recorder All Items in package 2 Fiber Optic Cable Puller Package Upgrade Kits Part Description 8690075 Pkg 1 to Pkg 3 Upgrade Kit Electronic Control Box with Chart Recorder and Load Cell 8690080 Pkg 1 to Pkg 2 Upgrade Kit Electronic Control Box and Load Cel 8675875 Pkg 2 to Pkg 3 Upgrade Kit Chart Recorder Chart Recorder Replacement Accessories Part Description 2273600 Chart Recorder Paper 0 2 000 Ibs 2245800 Ink Cartridge 3 pack Chessell recorder 2246001 Ink Cartidge single Jumbo Recorder Copyright 1992 A amp M Sales Inc Cal
43. 1 to 1 1 2 plastic innerduct If speed is your concern this is Without question the fastest tool for doing the job This puller comes in various lengths for pulling in multiple pieces of conduit so there is no need for a multiple pulling harnes These tools are made from stainless steel and aluminum for long life and durability Features Easy set up no tools required Fits both 1 and 1 1 4 ID Inner Duct No bundle size increase on OD because puller goes inside of duct Pull One Two or Three at a time Available in three lengths 12 18 and 24 for staggering Works on chinese finger principle Field tested and proven Pm EEE How toorder 1 Choose your tool with the desired leader 12 18 or 24 Washer 2 Choose the Jaw size for your innerduct In you are pulling innerduct 1 3 8 to 1 1 2 o a 1037W Washer is suggested Part Description Leader Length Part Description Size 106212P Innerduct Pulling Tool 12 1062J Jaws 1 to 1 1 4 106218P Innerduct Pulling Tool 18 10371 Jaws 1 1 4 to 1 1 2 106224P Innerduct Pulling Tool 24 6237 Spring Only 1037W Washer for 1037 J Only Reusable Power Cable Pulling Eyes Non crimp reusable cable pulling eyes waste virtually no cable and all components are completely reusable These eyes will remain firmly secured on the cable for a confident pull No special tools or crimpers are required for installation Three designs of Reusable Power Pulling Eye
44. 1 06 1 43 27 37 1 75 44 44 11 56 14 1 31 33 44 11 56 14 8960715 1 1 2 38 1 37 1 68 35 43 2 00 51 44 11 56 14 1 31 33 44 11 56 14 8960720 2 5 1 98 2 12 49 54 244 62 44 11 56 14 1 31 33 44 11 56 14 Innerduct Pulling Eye Installation Tool Fits on a 1 2 Drive Wrench to facilitate insertion of the eye into the innerduct Part Description 8913350 Installation Tool Universal Innerduct Couplings Part Duct Size Int 1 Number in mm 8565803 1 25 Best for use with corrugated duct 8567001 1 1 4 3 External d Part Duct Size Duct O D Range Couplings feature a tapered design E Number in mm in mm that provides a secure fit on nearly 22 8566010 l 25 1 23 1 42 31 2 36 1 all types of innerduct 8566012 1 1 4 32 1 49 1 70 37 8 43 2 8566015 1 1 2 38 1 80 2 01 45 7 51 1 8566020 2 51 2 31 2 52 58 7 64 0 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Clevis Head Innerduct Pulling Eye Same tapered threads as the standard innerduct pulling eye these pulling eyes feature a slotted head with clevis pin to permit direct attachment to multiple pulling harness leg ends When properly sized and installed these eyes will not pull out of the innerduct until the pulling tensions have greatly exceeded the maximum pulling tensions recommended by the innerduct manufacturers NOTE To determine correct pulling eye size obtain the actual innerduct inside diameter I D
45. 127 mm amp 6 152 mm adapters w retaining fork i FIOI condui poe D Running Line Tensiometer 5 127 mm amp 6 152 mm adapters w retaining fork 8674388 CableGlider STD Package 2 u Package d niue 8674820 Me id d verdi 5 for export only Chart recorder for running line tensiometer All items in Package 4 plus 8610686 CableGlider STD Package 3 Chart recorder for running line tensiometer Items in Package 1 plus 8674830 CableGlider STD Package 6 for export only Amp Type tensiometer All Items in Package 4 plus Amp Type tensiometer Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 CableGlider Plus Cable Puller This model comes equipped with the same removable two speed 6 500 Ibs 28 912 N power pack and accessories as our STD model but features a heavy duty frame with an extra pivoting arm for added performance and versatility In addition the front frame height can easily be adjusted with pins Like all CableGlider models the Plus is portable sets up quickly and comes completely self contained ready to work As with the STD model the CableGlider Plus features a self tailing capstan for added stability a pivoting arm and a footswitch for operator convenience and safety Accepts all diameter rope self tailing capstan accepts 5 8 16 mm to 78 22 mm rope only CableGlider Plu
46. 13 2l 1 44 37 59 15 141 36 44 ll 59 15 8917550 350 White 681 L7 1 25 32 56 14 1 34 34 38 10 59 15 8960350 250 Blue 575 15 1 13 29 38 10 1 06 27 31 8 93 13 8960450 4 0 Green 528 13 1 00 25 38 10 1 06 27 31 8 135 15 8960850 2 0 AWG Black 419 11 1 00 29 38 10 1 00 27 31 8 93 13 8960550 1 0 AWG Red 373 9 88 22 38 10 1 06 27 31 8 53 13 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Reusable Power Pulling Eyes Standard Head The Standard Head Power Pulling Eyes are an excellent alternative when pulling multiple cables into a single conduit Single conductors can be attached to a multiple pulling harness with links or with swivels Installation is then simplified to a single pull of one assembly Each Standard Power Pulling Eye includes an eye socket sleeve nut amp plug Max Max Part Conductor Dia Eye O D Number Cable Size Color in mm in mm 8917720 1750 kcmil Yellow 1 526 39 2 50 63 8917920 1500 kcmil Black 1 412 36 2 38 60 8917820 1250 Blue 1289 33 295 8917120 1000kemil Orange 1 152 29 206 52 8917220 750kcmil Brown 998 25 175 44 8917320 700 kcmil Gray 964 24 175 44 8917420 500 kcmil Yellow 813 21 LSO 38 8917520 350 kcmil White 681 17 125 32 8960320 250 kcmil Blue 575 15 113 29 8960420 4 0 AWG Green 528 13 L00 25 8960820 2 0 AWG Black 419 l L00 25 8960520 1 0 AWG Red 313 9 88 22
47. 165 JL 62 FO SR 24 8 5 8 3 4 750 Ibs 1 500 165 JL 75 FO SR 24 8 3 4 1 900 Ibs 2 000 Ibs JL 100 FO SR 24 8 1 11 4 900 Ibs 2 000 Ibs XIE Grips The XIE model has the same basic features as the X model However the XIE offers an interior pulling eye The interior eye is attached to a Part Mesh Working Breaking Number Length Range Load Strength strength member found on some fiber optic ble d the fib XIE 10 FO SW 10 10 25 500 1500 cable en the interior eye is used the fiber XIE 25 FO SW 14 25 37 500 1500 remains neutral and will not detach from the XIE 37 FO SW 24 25 50 750 2200 exterior insulation Please use an A amp M HD XIE 42 FO SW 24 42 61 750 2200 00 ball bearing swivel when installing fiber in XIE 53 FO SW 247 25374 750 2200 order to release tension that would otherwise XIE 64 FO SW 24 64 87 750 2200 damage the cable XIE 75 FO SW 24 75 1 00 750 2200 XIE 100 FO SW 24 1 00 1 25 750 2200 XIE 125 FO SW 24 1 25 1 50 750 2200 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Standard Fiber Optic Pulling Grip X FO Grips A amp M Sales now offers a flexible eye fiber optic cable pulling grip The grips are manufactured with high strength galvanized wire Add S S to the end of the part number if stainless steel mesh is required The Part Mesh Working Breaking flexible eye connects easily to a swivel or p
48. 2 51 1 98 2 20 50 56 35 57 9 14 8043921 2 51 1 98 2 20 50 56 50 70 13 18 Innerduct Organizer Plug Removable and reusable duct seal holds innerduct securely and prevents migration requires no foam or chemicals Easy installation Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Conduit I D Maximum Innerduct Innerduct O D Part Size Range number of Size Range Number mm in mm Innerduct in mm in mm 8093436 4 102 3 97 4 13 101 105 4 1 25 1 19 1 36 30 35 8093442 4 102 3 97 4 09 101 104 3 1 amp ll s 25 amp 29 1 30 1 42 33 36 8093467 4 102 3 97 4 09 101 104 3 11 8 amp 11 4 29 amp 32 1 53 1 67 39 42 Part Size Conduit I D Range Non Metallic Eye Nut Plug Number in mm in mm 8067811 1 25 36 1 16 24 29 Made of durable expansive polyurethane with rugged polypropylene 3067812 11 4 32 1 14 1 48 29 38 compression plates and eye nut No tools required for installation 8067814 1 1 2 38 1 49 1 83 38 46 Completely water and air tight 8067820 2 51 1 83 2 36 46 60 8067825 2 1 2 64 2 34 2 9 59 74 8067830 3 76 2 99 3 46 76 88 8067840 4 102 3 94 4 33 100 110 8067850 5 127 5 00 5 35 124 136 8067860 6 152 5 82 6 37 148 162 American Corporation American Polywater Corporation pioneered the development of water based polymer cable pulling lubricants over a decade ago Today American Polywater s polymer lubricants uniquely combine extremely low
49. 2 mounting hardware see mounting hardware Part Steel Size Ext from wall Number in mm in mm 8381500 5x 1 00 13x25 35 8 89 8383900 5x 1 00 13 25 69 16 165 8383800 5x 1 25 13x32 69 16 165 Corner Rack Support To bolt the racks at manhole corners Mounting bolt holes for 1 2 or M12 bolts see mounting hardware Formed of 1 1 2 x 1 4 38 x 6 mm steel and hot dip galvanized Part Description 8383700 9 x 12 228 x 305 mm legs 8383600 12 12 305x305 mm legs Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Manhole Ladders ladders are manfactured of steel The rungs pass through the side rails and are riveted or welded The unique design assures a rung cannot turn Manhole Ladders Wall Mount ladders are manufactured of steel The rungs pass through the side rails and are riveted or welded Features Features e5 8inch 16 rnm diameter deformed rungs on 12 inch 5 8 inch 16 mm diameter knurled rungs on 12 inch 305 305 mm centers mm centers 14 inches 356 mm clearance between side rails 12 inches 305 rnm clearance between side rails e 3 8 x 1 1 2 inch 10 x 38 mm side rails through 12 foot 3 7 m lengths e 3 8 x 2 1 2 inch 10 x 64 mrn side rails 13 foot 4 Oin length and above e2x 1x 1 8 51x25 x 3mm channel side rails e Furnished with 4 unattached floor ceiling brackets e Wall mounting b
50. 25 6 500 28 912 8617260 6 114 450 114 5 37 136 5 90 150 6 500 28 912 8617360 6 114 4 50 114 5 00 127 5 56 141 6500 28 912 8617280 8 203 6 00 152 7 18 182 7 94 2 02 6500 28 912 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Cable Bending Shoe Protects cable from corner abrasion during pulling operations Made of cadmium plated 13 gauge steel with a protective polymer coating to extend the life Part Description Size 86570 Cable Bending Shoe 3 86571 Cable Bending Shoe 3 1 2 Nylon Cable Protector Flanged split tube to insert in duct end and protect cable from damage during installation Also can be left in place for permanent protection Part Description 8042301 1 2 1 2 25 63 mm Duct 8042300 3 6 76 152 mm Duct Support Bar Used to support quadrant blocks or cable guides at street level Part Description 8091440 1 1 4 32mm x 4 1 2m Steel Bar Chains Used to tie off cable guides in the manhole Not to be used for overhead lifting Part Description 8066301 4 1 2 m Chain Double Hook 3 16 9mm Alloy Links 7 100 Ibs 31 581 N capacity 8066300 8 2 4m Chain Double Hook 3 8 9mm Alloy Links 7 100 Ibs 31 581 N capacity Replacement Sheaves Condux Refer to this chart for specifications on sheave sizes for these products Hooked Hanger Sheave Cable Feeding Sheave Corner Cable Guide Heavy Duty Quadrant Block Fi
51. 3 6 00 152 8082080 8 203 3 25 83 8 00 203 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Wire Brush Mandrel Body Flat steel bristles with a pulling eye on one Sd od pt in pus in ico 8028904 1 1 4 32 425 108 1 00 25 removes sand grit and other light obstruc 2028905 1 1 2 38 425 108 125 32 tions from the duct 800 Ibs 3 558 N load 8028900 2 51 4 25 108 1 75 44 capacity 8046000 2 1 2 64 4 25 108 2 29 57 8067100 3 76 5 50 140 2 13 70 8067200 3 1 2 89 5 00 127 2 29 82 8029000 4 102 6 75 171 3 75 95 8029100 5 127 6 50 165 4 75 121 8068100 6 152 6 75 171 9503 146 8029080 8 203 4 75 121 Ido 197 Heavy Duty Wire Brush Mandrel Body Load Part Duct Size Length Max O D Capacity Heavy duty steel bristles with pwling eyes on rini hp dmm ft m Ibs N each end For removing obstructions from the 8029104 2 51 3 50 89 175 AA 1 240 5 516 duct 8046001 2 1 2 64 4 25 108 2 25 SU 1 240 5 516 k 8067101 3 76 5 25 133 2 129 70 1 240 5 516 Lr 8067201 3 1 2 89 5 25 133 3 23 82 2 240 9 964 0 E 8029001 4 102 SWA 133 3 75 95 2 240 9 964 8029101 5 127 5 00 127 4 75 121 2 240 9 964 8029105 6 152 5 00 127 DS 146 2 240 9 964 Flexible Steel Mandrel mony Part Duct Size Length Max O D Steel discs in graduated sizes make this Number in mm in mm in mm mandrel ideal for removing obstructions in 8021700 7 51 1 31 186 1 75 AA duct
52. 4 102 3 54 425 90 108 8032965 5 Quick Conduit Seal Off 5 127 472 537 120 136 8032970 6 Quick Conduit Seal Off 6 152 5 50 6 29 140 160 8032975 8 Quick Conduit Seal Off 8 203 7 83 8 27 199 210 Nominal Replacement Seals for Compressor Seal Offs Duct Size Part in mm 8082121 2 51 8082126 2 1 2 63 8082131 3 76 8082136 3 1 2 89 8082141 4 102 8082151 5 127 8082161 6 152 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 rr amp m sales inc p o box 171 chagrin falls ohio 44022 440 708 0180 Power Dart Blower The Power Dart Blower is a pneumatic rodding system especially suited for long duct runs A three motor system allows you to choose the right speed for your needs With all three motors engaged the Power Dart Blower will deliver up to 300 cfm 8 5 m min of air at 3 psi 2 bar max pressure easily blowing 1 2 13 mm poly line or measuring tape over 2 000 feet 610 m in conduit up to 6 inches 152 mm in diameter The complete kit comes with 25 feet 7 6 m of air hose an assortment of conduit seal offs and an assortment of carriers Weighs only 31 pounds 14 kg and operates at or 220 Volts 11O Volt model includes a 30 amp twist plug The 220 Volt model is supplied without a plug Requires a 3 000 Watt generator Utility Power Kit Includes the following items for utility applications Blower Unit e 25 8 m x 2 1 2 64 mm heavy duty hose
53. 40325 4 Way 1 4 6mm Cable 1 400 6 227 4 200 18 682 3 75 95 14 356 62 16 25 6 8569910 5 Way 1 4 6mm Cable 1 400 6 227 4 200 18 682 3 75 95 14 356 62 16 25 6 8549333 Way 3 8 10mm Cable 4 800 21 350 9 000 40 032 2 63 67 10 254 62 16 7 10 8549329 4 Way 3 8 10mm Cable 4 800 21 350 9 000 40 032 2 63 67 10 254 62 16 10 8549331 2 Way 1 2 13mm Cable 7 000 31 136 10 000 44 480 2 50 64 12 305 50 13 50 13 8549332 Way 1 2 13mm Cable 7 000 31 136 15 000 66 720 3 75 95 12 305 87 22 50 13 8549340 4 Way 1 2 13mm Cable 7 000 31 136 15 000 66 720 3 75 95 12 305 87 22 50 13 8549255 3 Way Link Chain 3 500 15 568 5 000 22 240 3 50 89 14 356 50 13 31 8 8549250 3 Way Link Chain 3 500 15 568 5 000 22 240 3 50 89 14 356 50 13 31 8 8549254 4 Way Link Chain 3 500 15 568 5 000 22 240 3 50 89 14 356 50 13 31 8 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 D Drill amp Directional Drilling Swivels Designed specifically for directional drilling the 819 D Drill Swivels prevent boring equipments rotational torque from interfering with the product cable or conduit being pulled The D Drill Swivels are greasable and double sealed to keep contaminants out Clevis pins with hex nuts allow for installation and removal from either side of the swivel There is a 90 day warranty on the directional drill swivels CAUTION To be used for directional drilling only
54. 46 4 102 8610648 5 127 8610649 6 152 Offset Adapters Duct Size Part Number in mm Offset Adapter 8674029 2 51 8674026 3 76 N aN 8674036 30 pr R 8674037 45 bag TAE m 8674038 60 Ke 8674039 80 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Accessories Part Description Elbow 8610667 Tool Box for Accessories Adavt 867402 1 Retaining Fork for 2 4 51 102 mm Conduit Adapters peer 8674022 Retaining Fork for 5 6 127 152 mm Conduit Adapters 8674014 4 102 mm 45 Elbow Adapter 8674017 Complete Tool Box includes all six Items Above Extension Cords Part Number Description 8677325 120 Volt 20 Amp Twist 25 7 6 m Extension Cord 8677330 120 Volt 20 Amp Twist 100 30 m Extension Cord 220 Volt Extension Cords are available upon request Amp TypeTensiometer 8 for HD Model sy amp Amp Type Tensiometer Amp Type Tensiometer f Part Description or 8674100 110 Volt Amp Type Tensiometer STD amp Plus models STD amp Plus 8674501 110 Volt Amp Type Tensiometer HD model Models wd 8674502 220 Volt Amp Type Tensiometer STD amp Plus models for export only 8674503 220 Volt Amp Type tensiometer HD model for export only Running Line Tensiometer The Running Line Tensiometer used with CableGlider cable pullers or other rope capstan pullers will give accurate measurements of the force exerted on a cable as it
55. 46 Blue Green 8074605 1 400 6 227 Green Red 8015005 600 2 669 Orange black 8076905 1 500 6 672 Green Yellow 8018605 650 2 891 Slate Green 8019205 1 600 7 117 Black White 8076005 700 3 114 Orange White 8019305 1 700 7 562 Red White 8075505 750 3 336 Orange V iolet 8017705 1 800 8 006 Brown Black 700 18 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 EN a amp m sales inc p o box 171 chagrin falls ohio 44022 440 708 0180 Eye to Eye Connectors Light duty winch line pulling connector drop forged from C 1035 steel Hot dip galvanized Part Size Working Load Number in mm Ibs N 8050300 3 8 10 2 200 9 786 8050500 1 2 13 3 600 16 013 8050501 5 8 16 5 200 23 130 Threaded Chain Connectors Offer a quick and easy way to attach pulling eyes or swivels to winch lines harnesses or d nas i rope To close simply screw the nut onto the threaded end Connectors are reusable Note To beused for cablestringing or pulling only i Work Load Stock Diameter 7 A Part Limit S A B C Number Ibs N in mm in mm in mm in mm 8581212 200 890 0 125 3 2 0 575 9 5 1 813 46 0 1 563 40 8581218 550 2 446 0 188 4 8 0 500 12 7 2 438 61 9 2 063 52 6581225 TIO 3 425 0 250 6 4 0 563 14 3 2 750 69 9 2 9129 39 8581231 1 430 6 361 0 313 1 9 0 688 17 5 3 438 87 3 28 13 71 8581237 1 760 7 828 0 375 9 5 0 750 19 1 3 750 95 3 3 000 76 8581250 2 123
56. 500 33 360 1 7 16 87 59 15 5 13 130 1 41 36 44 11 59 15 70139 10 000 44 480 1 5 8 41 69 18 5 44 136 8210018 10 000 44 480 1 7 8 48 5 19 7 06 179 1 88 48 63 16 81 21 13L 12 000 53 376 1 1 4 32 59 15 4 34 109 1 13 20 38 10 44 11 B 13L 22 500 100 080 1 7 16 36 59 15 5 13 129 1 38 35 44 11 14 70140 25 000 111 200 2 1 2 62 5 34 9 9 63 240 C13L 30 000 133 440 1 7 8 47 T3 19 7 07 1 75 44 63 16 82 21 D 15345 48 000 213 504 2 7 16 61 1 00 25 10 19 255 2 69 68 88 22 1 13 29 Rope to Swivel Clevis Used to connect the swivel to rope up to 1 25 mm in diameter To be used with an 808 Champion swivel of the same size only Part Size Max O D Load Rating Number in mm in mm in mm 8091212 1 1 4 32 2 51 4 000 17 792 8091213 1 3 8 35 2 51 6 500 28 912 8091216 1 5 8 41 2 51 8 500 37 808 8091220 2 51 2 51 10 000 44 480 to Rope Grip Clevis Versatile clevis provides efficient link for several applications All steel construction with 10 000 Ibs 44 480 N load capacity Combinations of sheaves and pins allow the following connections 3 4 19 mm diameter rope to 3 4 19 mm diameter rope Rope to forged eye pulling grip Forged eye pulling grip to forged eye pulling grip Rope to flexible eye pulling grip Part Max O D Number in mm 8091200 1 3 4 44 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466
57. 80 80 8032100 3 1 2 89 3 50 89 8032600 4 102 4 00 102 8059100 5 127 5 00 127 8059200 6 152 6 00 152 Line Carriers Fast and efficient plastic carriers for fishing with highspeed blowers even in out of round duct Carrier will travel over minor obstructions in duct Part Duct Size Max O D Number in mm in mm 8067900 2 51 2 06 52 8030100 3 76 3 06 78 8030200 3 1 2 89 3 56 90 8030300 4 102 4 06 103 8030400 5 127 5 06 129 8030500 6 152 6 06 154 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 a amp m sales inc p o 171 chagrin falls ohio 44022 440 708 0180 Inflatable Carriers Rip stop nylon bag conforms to cable occupied ducts One carrier can be used in a variety of duct sizes or when the duct size changes throughout the run Easy pull back Part Duct Size Number in mm 8032700 3 4 1 1 4 19 32 8032800 1 1 2_2 1 2 38 64 8031600 3 4 76 102 8031700 4 6 102 152 Duct Projectile Flexible rubber cones are durable for many repeated uses Fast and efficient for long runs with easy pull back Part Duct Size Max O D Number in mm in mm 8031812 1 1 4 32 1 25 32 8031814 1 3 8 35 1 37 29 8031815 1 1 2 38 1 50 38 8031816 1 5 8 41 1 62 41 6031820 2 50 2 00 50 8031822 2 1 4 56 2 20 56 8031825 2 1 2 64 2 50 64 8031830 3 76 3 00 76 8031835 3 1 2 89 3 50 89 8031840 4 102 4 00 102 8031844 4 1 4 108 4 25 108 8031846 4 1 2 115 4 51 115
58. 888 553 6466 EIN a amp m sales inc p o box 171 chagrin falls ohio 44022 440 708 0180 Running Line Tensiometer Package 2 Includes the following items Mechanical Sensing Unit Electronic Control Box Chart Recorder Mounting Hardware Part Description 8674230 110 Volt RLT fo CableGlider STD with chart recorder 8674242 220 Volt RLT for CableGlider STD with chart recorder for export only Running Line Tensiometer Package 2 110 Volt Y AA CableGlidder STD Chart Recorder Replacement Accessories EI Part Description x T i m 2245600 Z fold chart paper replacement for STD 2246001 Ink Cartridge Replacement Juno recorder 2245800 Ink Cartridge 3 pack Chessell recorder Running Line Tensiometer CableGlider Plus Measures loads of 0 to 6 500 Ibs O to 28 912 N with an accuracy of 325 Ibs 1 446 N Running Line Tensiometer Package I Includes the following iterns Part Description Mechanical Sensing Unit 8674228 110 Volt RLT fo CableGlider Plus e Electronic Control Box 8674241 220 Volt RLT for CableGlider Plus Mounting Hardware for export only Running Line Tensiometer Package 2 UT Includes the following items Mechanical Sensing Unit Part Description Electronic Control Box 8674225 110 Volt RLT fo CableGlider Plus with chart recorder Chart Recorder 8674240 220 Volt RLT for CableGlider Plus with chart recorder Mounting Hardware for export only Ch
59. 9300 1 700 7 562 71408 600 2 670 8076000 700 3 114 8017700 1 800 8 006 8017200 600 2 669 901 3300 750 3 336 8017500 650 2 891 Dimensions on Stared Swivels may vary call for details 70191 700 3 115 5 8 Swivels with the next to the are made out of Steel 8017900 750 3 336 7 8 Swivels with the next to them are made out of Aluminum Replacement Pins Break pins for th 5 8 amp 7 8 Break Away swivels are easy to order and ready to ship L m Break Pin a A Bearings Externally Body Internally Threaded Head Threaded Head Replacement Pins for Replacement Pins for 7 8 Swivel 22 mm Replacement Pins for 5 8 Swivel 16 mm Part Break Load 7 8 Swivel 22mm Part Break Load Number lbs N Color Part Break Load Number lbs N Color 8018105 150 667 Slate White Number lbs N Color 8017305 200 890 Green Black 8018305 200 890 Green Orange 8018705 800 3 558 Red Yellow 8017405 250 1 112 Blue White 8018005 250 1 112 Blue White 8018805 850 3 781 Black Yellow 8017805 300 1 334 Blue Violet 8017605 300 1 334 Brown Red 8076605 900 4 003 Orange Yellow 8016905 450 2 002 Blue Yellow 8018405 350 1 557 Black Green 8015705 1 000 4 448 Green White 8017205 600 2 669 Orange Black 8075305 400 1 779 Blue Black 8018905 1 100 4 893 White Yellow 8017505 650 2 891 Brown White 8015805 450 2 002 Blue Yellow 8015205 1 200 5 338 Brown White 8017905 750 3 336 Orange Violet 8076505 500 2 224 Orange Red 8019105 1 300 5 782 Brown Yellow 8018505 550 2 4
60. CAUTION A amp M Sales requires the use of a calcium based lubricant only Other lubricants may have adverse reactions when exposed to bentonite products A amp M Sales requires that the swivels be flushed with grease after each use to purge any contaminants that may have penetrated past the seals into the swivel while boring Working Load Part Tension Compression Number Ibs N Ibs N 8190016 8 500 37 808 2 800 12 454 8190020 10 000 44 480 3 300 14 678 8190025 20 000 88 960 6 600 29 357 8190030 30 000 133 440 10 000 44 480 8190040 45 000 200 160 15 000 66 720 8190045 60 000 266 880 20 000 88 960 8190060 90 000 400 320 30 000 133 440 8190080 120 000 533 760 40 000 177 920 Universal Joints A in mm 1 5 8 41 2 51 2 1 2 64 3 76 4 102 4 5 8 117 6 152 8 203 174 199 278 324 387 444 464 B in mm in mm 63 16 6 85 75 19 7 83 1 00 25 10 93 1 31 33 12 75 1 68 41 1525 1 75 44 1748 2 00 51 1827 225 57 2171 532 in mm in mm in mm in mm 159 40 56 14 20 2 36 60 181 46 63 16 19 2 89 73 2 84 72 88 22 1 25 32 3 67 93 3 56 90 1 13 29 137 36 4 50 114 400 102 1 25 32 1 84 47 5 58 142 462 117 1 50 38 2 13 54 6 31 160 450 114 1 75 44 218 56 6 59 167 5 25 133 2 00 51 2 50 64 8 25 210 A amp M Sales U Joints are used to aid the pulling of conduit or other material in a directional drilling application Used in conjunction with D Drilling Swivels U Joints prevent side loading and
61. Cable Guide Features two hardened steel rollers that guide steel winch line over sharp edges It 1s small but sturdy allowing for easy handling and set up along with heavy duty capacities 10 000 Ibs 44 480 N cable tension load capacity Replacement sheaves available Part Description 8045000 Mini Corner Cable Guide Corner Cable Guides Aluminum sheaves for pulling cable into manholes 5 000 Ibs 22 240 N cable tension load capacity Replacement Sheaves available See Specifications and Selection Charts Support bar sold separately Condux GMP Part Size Part Number in mm Number Size Weight 8040000 3 76 70283 3 32 165 E 8043100 4 102 70284 4 55 Ibs 8043200 5 127 70285 S 65 165 8088600 6 152 60975 5 HD 65 Ibs s 8088800 8 203 Heavy Duty REEL o Cable Feeding Sheaves Plugs into conduit in manhole wall guiding cable safely into the conduit regardless of the pulling angle Replacement Sheaves available Part Size A I D O D Load Capacity Number in mm in mm in mm in mm lbs N 8617215 1 1 2 38 104 26 1 25 32 144 37 1 500 6 672 8617220 2 51 1 38 35 1 75 44 1 95 50 2 600 11 565 8617225 2 1 2 63 144 37 2 16 55 240 61 2 600 11 565 8617230 76 2 05 57 2 62 67 2 95 75 4 800 21 350 it 8617235 3 1 2 89 2 75 70 3 00 76 3 38 86 4 800 21 350 A gt J 8617200 4 102 300 76 3 50 89 3 95 100 6 500 28 912 i 86173407 4 102 3 00 76 3 25 83 3 65 93 6 500 28 912 8617250 5 127 3 75 95 4 50 114 4 90 1
62. EN a amp m sales inc p o box 171 chagrin falls ohio 44022 440 708 0180 Duct Rodders A amp M duct rodders combine ease of operation and reliable performance to help increase the efficiency of your rodding operations Our duct rodder cages have been designed to be lighter weight for easy handling in the field They feature sturdy construction and a hand operated wheel brake They can be used on their side as well as upright Larger cages come with flotation wheels for added mobility Cage sizes are matched to suit the rod you order End Fittings Included A amp M duct rods come equipped with a threaded end fitting on each end plus a tapered head on the outward end A amp M offers a number of optional end fitting accessories for additional applica tions Easy to Order Simply refer to the charts in this section based on the diameter of rod you need A amp M provides 48 hour turnaround on most rodder orders Three Types of Rod A amp M Sales offers three types of duct rod Cobra Python and Mini Cobra Each has a glass reinforced composite core jacketed in a rugged plastic coating to ensure long life All three have excellent flexural strength compressive strength fatigue resistance and memory They also have favorable electrical and thermal properties that make them safe for use in cable occupied duct They are suitable for pulling back winch line or small diameter cable COBRA Cobra is our highest qualit
63. The I D measurement must be greater than dimension A and smaller than dimension B ti s WEET IU L T Innerduct Max O D Hole Dia Slot Width Slot Depth Pin Dia Pin Center Part Nominal Size I D Range C D E F G H Number in mm A B in A B mm in in mm in mm in mm in mm in mm 8913500 3 4 19 68 81 17 21 1 13 29 23 6 38 10 1 06 27 31 8 53 13 8913501 7 8 22 81 93 21 24 1 25 32 28 6 56 14 1 34 34 38 10 59 15 8913502 1 23 93 1 06 24 27 1 38 35 38 10 56 14 1 31 33 44 11 56 14 8913340 1 25 98 1 14 25 29 1 38 29 38 10 56 14 1 31 33 44 11 56 14 8913503 1 1 4 32 1 06 1 18 27 30 1 44 37 38 10 59 15 1 41 36 44 11 59 15 8013504 1 1 4 32 1 18 1 34 30 34 1 63 41 38 10 63 16 1 59 40 56 14 78 20 8913341 1 1 4 32 1 23 1 39 31 35 1 63 41 38 10 63 16 1 59 40 56 14 78 20 8913505 1 1 2 38 1 34 1 50 34 38 1 88 48 38 10 do 19 1 88 48 63 16 81 21 8913506 1 1 2 38 1 50 1 62 38 41 2 00 51 38 10 T3 19 1 78 45 63 16 72 18 8913507 1 3 4 44 1 68 1 81 43 46 2 00 51 38 10 19 1 78 45 63 16 2112 18 8913510 2 5 1 82 1 96 46 50 2 50 64 38 10 1 00 23 2 68 68 88 22 1 25 32 8913508 2 51 1 96 2 09 50 53 2 50 64 38 10 1 00 23 2 80 71 88 22 1 25 32 8913509 2 5 2 06 2 18 52 56 2 50 64 38 10 1 00 25 2 80 71 88 22 125 32 Fixed Head Innerduct Pulling Eye Tapered buttress threads thread into the innerduct for maximum pulling strength These eyes connect directly toa swivel When properly sized an
64. ale 8033487 8033486 8036318 8036319 8036316 Female 8036317 8036314 8036315 Copyright O 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 rr amp m sales inc p o box 171 chagrin falls ohio 44022 440 708 0180 Epoxy Use with end fittings or splice tubes to repair duct rodders Part Description 8035851 Single pack for replacing end fitting 8035852 Double pack for splice tubes Splice Kit Use to repair duct rod if it breaks towards the middle of the duct rod Kit includes splice tube epoxy and installation instructions Rod Dia in mm 3 16 5 1 4 6 5 16 8 7 16 11 9 16 13 Splice Kit 8033457 8033465 8035753 8035751 8035752 Splice Tube Only 8033455 8033463 8035703 8035701 8035702 Tapered Head Attaches to the end fitting on the duct rod Guides duct rod through the conduit and allows a pull line diameter A to be attached to the duct rod Comes standcad with each of the duct rodders Rod Dia in mm 3 16 5 1 4 6 5 16 8 7 16 11 9 16 13 USC Thread 12 24 5 16 18 3 8 16 3 8 16 3 4 10 8033421 8033441 8038400 8038400 8038300 Diameter A 156 4 156 4 281 7 281 7 343 9 Metric Thread 5 8 12 12 M12 Tapered Head 8033410 8033480 8038301 8038301 8038301 Diameter A 156 4 156 4 281 7 281 7 281 7 O Rings Used to help keep accessories on the end fitting while rodding Comes standard with the Mini Cobra ro
65. art No 0 35 0 42 0 35 0 48 0 35 0 48 8 9 10 7 08 9 12 2 9761400 891535 8761401 793 048 0 35 0 60 8761350 10 8 12 2 m eene 0 49 0 60 0 49 0 60 ego 14 1 15 2 8761424 932 048 8643755 2615s 8 1 12 2 03329 1195 0 42 0 61 8643756 10 7 15 5 033 29 1196 0 53 0 74 8643757 13 5 18 8 033 29 1197 0 61 0 67 0 61 0 73 061 073 gre ane 153 170 8761428 15 3 18 5 15 3 18 5 0 68 0 73 cag 0 61 0 85 8761355 17 1 18 5 15 3 21 6 Pack 2 0 74 0 79 8761430 0 74 0 85 0 74 0 85 86 2041 0 64 0 87 8643758 16 3 22 1 033 29 1198 18 6 21 6 18 6 21 6 0 80 0 85 202 216 8761431 0 86 0 92 0 86 0 97 0 86 0 97 21 7 23 4 8761432 8761409 0 93 0 97 8761433 0 86 1 13 8761360 23 5 24 6 21 7 28 7 Pack 3 0 98 1 04 0 98 1 13 0 98 1 13 24 7 26 4 71535 24 7 28 7 24 7 28 7 105 113 ease 26 5 28 7 0 75 1 00 8643759 19 1 25 4 033 29 1199 21 7 24 6 21 7 24 6 1 00 1 24 8643137 25 4 31 5 033 03 013 1 00 1 24 8643137 3761437 49 4315 033 03 013 30 3 31 8 1 14 1 19 L14 125 8761365 1 14 1 25 114125 088 302 28 8 31 8 4 28 8 31 8 28 8 31 8 1 20 1 25 Continued On Next Page Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 DUCT PACK Duct Size 1 8761370 SDR 11 13 5 Pack 1 DUCT CLAMP 8761414
66. art Recorder Replacement Accessories Part Description 8674225 110 Volt RLT fo CableGlider Plus with chart recorder 8674240 220 Volt RLT for CableGlider Plus with chart recorder Mechanical Sensing Unit for export only mounted on Running Line Tensiometer CableGlider HD CableGlidder HD or Plus Measures loads of 0 to 12 000 Ibs 0 to 53 376 with an accuracy of 600 Ibs 2 669 Running Line Tensiometer Package I Includes the following iterns Mechanical Sensing Unit Electronic Control Box Mounting Hardware Part Description 8674222 110 Volt RLT fo CableGlider HD 8674241 220 Volt RLT for CableGlider HD for export only Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Running Line Tensiometer Package 2 110 Volt CableGlidder HD Running Line Tensiometer Package 2 Includes the following items Mechanical Sensing Unit Electronic Control Box Chart Recorder Mounting Hardware Part Description 8674212 110 Volt RLT fo CableGlider HD with chart recorder 8674240 220 Volt RLT for CableGlider HD with chart recorder for export only Chart Recorder Replacement Accessories Part Description 2245700 Z fold chart paper replacement for HD 2246001 Ink Cartridge Replacement Juno recorder 2245800 Ink Cartridge 3 pack Chessell recorder Fiber Optic Cable Puller The Fiber Optic Cable Puller sets new stan
67. available to accommodate various pulling needs Break loads range from 1 900 Ibs 8 451 N to 22 000 Ibs 97 856 N and are designed to separate at 10 of their rated break load Order Replacement Pins as needed NOTE D DrillSwivels come with a 90 day limited warranty WARNING These swivels are to be used while Directional Drilling only Severe personal injury could result if used with rope or steel winch lines in cable pulling applications Break A way D Drill Swivel Break A way D Drill Swivel 1 1 4 1 3 8 1 5 8 3 1 1 4 Swivel 32mm 1 5 8 Swivel 41mm Part Break Load Part Break Load Number Ibs N Number Ibs N 8019400 1 900 8 451 8024500 7 000 31 136 8019500 2 000 8 896 8025500 7 500 33 360 8019600 2 500 11 120 8027900 8 000 35 584 8019700 3 000 13 344 8028400 8 500 37 808 8076100 3 400 15 123 2 Swivel 51mm 8019800 4 000 17 792 Part Break Load Number Ibs N e Swivel 35mm 8029200 9 000 40 032 ii 8029400 10 000 44 480 Number Ibs N 8019900 4 500 20 016 2 1 2 Swivel 64mm 8021300 5 000 22 240 Part Break Load 8022100 5 500 24 464 Number Ibs N 8024200 6 000 26 688 8029600 12 000 53 376 8024400 6 500 28 912 8029700 14 000 62 272 3 Swivel 64mm Part Break Load Number Ibs N 8075600 18 500 82 288 8075800 22 000 97 856 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Use the
68. aves available Part Description 8539550 Fiber Optic Hanger Block Vs ae Overhead Fiber Optic Cable Sheave Specially designed in cooperation with Alcoa Fujikura Ltd for guiding fiber optic or CATV cable safely and efficiently these Cable Sheaves feature an innovative hanger arm that eliminates the possibility of cable coming off the sheave or binding against the support arm With the removal of a pin the hanger arm separates and allows cable to be slipped in easily even at midpoints A 22 inch 559 mm sheave diameter allows for a gentle cable arc Aluminum sheave construction means durability with less oe Maximum capacity is 1 500 lbs 6 672 N Replacement Sheaves available Part Description 8637825 Overhead Fiber Optic Cable Sheave i Underground Fiber Optic Cable Sheave The Underground Fiber Optic Sheave has all the features of the Overhead Sheave above but with an additional second arm for convenient tie off Replacement Sheaves available Part Description 8637800 Underground Fiber Optic Cable Sheave Fiber Optic Sheave Mount Fiber Optic Sheave Mounts are an ideal solution to mid point cable pulling situations The Adjustable Sheave Mount allows pinpoint adjustment from horizontcd to vertical Portable components set up quickly and adjust from job to job offering maximum versatility with minimum equipment Uses a standard 2 1 2 square mounting post for use with FO Cable Puller Remote M
69. ber Optic Quad Block Fiber Optic Hanger Block 3 Sheave Cable Guide Fiber Optic Sheave Mount Overhead and Underground Fiber Optic Cable Sheave and Jamb Skid Maximum Min Bending Max Sheave Maximum Cable O D Radius Width Sheave O D Shaft Dia Part Sheave Size A B C D E Number in mm in mm in mm in mm in mm in mm 8539308 1x3 25 x 76 1 50 38 J3 19 3 00 76 3 00 76 62 15 8539036 9x 76 x178 3 00 76 2 23 57 3012 94 7 00 2 03 1 25 31 8539136 4x7 102 x 178 4 00 102 2 29 57 4 31 109 7 00 2 03 1 25 3l 8539236 5x7 127 x 178 5 00 127 2 25 57 SN E 130 7 00 203 1 25 3l 8046611 3x11 76 x 279 3 00 76 4 25 107 3 75 95 11 00 279 1 25 3l 8046711 4x 11 102 x 279 4 00 102 3 13 95 4 75 120 11 00 279 1 25 31 8046811 5 11 127 x 279 5 00 127 329 82 5 75 146 11 00 279 1 25 31 8087811 6x11 152x279 6 00 152 3 12 79 75 171 11 00 279 1 25 3l 8087911 8xll 203 x 279 8 25 209 2 15 69 8 75 222 11 00 279 1 25 3l 8065411 4x20 102x508 4 25 107 8 50 215 4 75 120 20 00 508 1 25 3l 8042911 5x20 127x508 5 00 127 8 00 203 5 75 146 20 00 508 1 25 31 8637743 3x24 76 x 609 1 38 35 11 125 282 4 00 102 24 125 613 1 00 29 8043011 5x26 1 2 127x673 5 00 127 11 31 287 5 75 146 26 50 376 1 25 31 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 EN a amp m sales inc p o box 171 chagrin falls ohio 44022 440 708 0180 Cable Racks Supports cable runs in manholes and vaults Made of 1 1 2
70. binding that may occur at points in a directional bore To ensure load rating and size match U Joints are available with the same specifications as the 819 D Drill Swivels Part Number 8190316 8190320 8190325 8190330 8190340 8190345 Working Load Tension A B C D E Ibs N in mm in mm in mm in mm in mm 8 500 37 808 1 5 8 41 16 688 175 159 40 56 14 10 000 44 480 2 51 75 19 797 202 1 81 46 63 16 20 000 88 960 2 1 2 64 1 00 25 11 13 283 2 84 72 88 22 30 000 133 440 3 76 131 33 13 75 349 356 90 113 29 45 000 200 160 4 102 163 41 17 25 428 4 00 102 1 25 32 60 000 266 880 4 5 8 117 1 75 44 20 75 527 4 63 118 1 50 38 Directional Drilling Grease F G H J in mm in mm in mm in mm 20 236 60 19 2 89 73 73 19 76 19 1 25 32 367 93 298 25 89 23 1 38 35 450 114 129 33 1 14 29 184 47 558 142 161 41 126 32 2 12 54 631 160 1 73 44 1 52 39 Specially formulated for use in a bentonite clay environment This is an extreme pressure multiservice lubri cant designed to give outstanding performance in directional drilling boring applications Manufactured from the highest quality petroleum oil and thickened with a unique calcium complex soap This thickener resists breakdown caused by bentonite which is common with lithium based lubricants Packaged in car tridges to fit a standard grease gun Standard package quantity is 10 cartridges Part 4 8190007 Description Directional Drilling Grease
71. d 8036150 3 4 10 male end for 5 8 16mm rod 8036151 3 4 10 female end for 5 8 16mm rod Mud Scoop Attaches to the end of the hand rods and is used to clear the conduit of mud The mud scoop is pushed into the conduit it fills with mud and is then pulled back out and cleaned This process is repeated until the conduit is cleaned of mud Works in four inch 102 mm or larger conduit only Does not negotiate tight bends Rod Dia in mm 3 16 5 1 4 6 5 16 8 7 16 11 9 16 13 US Thread 412 24 5 16 18 3 8 16 3 8 16 3 4 10 Mud Scoop 8049302 8049302 8049301 Metric Thread M5 MS M12 M12 M12 Mud Scoop 8049304 8049304 8049304 Winch Line Blower The Winch Line Bloweris a method of installing winch line in conduit It turns the job of pulling winch line into one easy step eliminating the need to blow a string and pull back arope Using compressed air 65 psi 4 5 bar and 100 cfm 2 8 m min the Winch Line Blower can propel up to 5 8 16 mm steel winch line or 3 4 19 mm rope up to 1 600 feet 500 m depending on job conditions in conduit from 1 1 2 38 mm to 8 203 mm in diameter Typical travel time is 5 to 7 minutes for 1 400 feet 427 m in 4 102 mm conduit Easy Installation o a i Installation is easy No special tools are required The blower s seal off slides 7 a t het into the duct and is held in place by hand tightening the adjustment handles Expands to fit a range of Conduit ID
72. d 8040800 4 102 4 102 Round 8087200 4 102 5 127 Round 8040900 5 127 4 102 Round 8041300 5 127 5 127 Round 8041200 5 127 5 152 Round 8087000 6 152 5 127 Round 8086800 6 152 6 152 Round 8040133 4 102 3 1 4 83 Square 8040136 4 102 3 1 2 89 Square 8040142 4 102 4 102 Square Split Cable Guides Ease of removal from cable being installed allows for figure eight type installation so cable remaining on reel can be pulled in a different direction without having to terminate and splice Ideal for use with pre connectorized cable Split feeder is hinged on one side and has a series of flexible latches on the other side to allow full closure Requires steel duct adapters Fi Split Guide Split Guide Part Diameter Length 1 Number in mm ft m 8064700 4 102 7 M2 2 3 Extensioin for Split Cable Guide Extension Extension Part Diameter Length Number in mm ft m 8064800 4 102 3 1 2 1 1 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Jamb Skid The Jamb Skid is a device for supporting sheaves or quadrant blocks inside a manhole to pull cable into underground condiut By positioning the top of the jamb skid against the underside of the manhole opening and using the camlock foot pedal set up can be done in a fraction of the time it takes to install a hanging sheave assembly Pulling tension actually increases the stability of the jamb skid during the pull No dang
73. d installed these eyes will not pull out of the innerduct until the pulling tensions have greatly exceeded the maximum pulling tensions recommended by the innerduct manufacturers NOTE To determine correct pulling eye size obtain the actual innerduct inside diarneter I D The I D measurement must be greater than dimension A and smaller than dimension B gt n Fin i NL MX 4 We Att Innerduct Max O D Hole Dia Eye Dia Part Nominal Size I D Range C D E Number in mm A B in A B mm in mm in mm in mm 8913318 3 4 19 68 81 17 21 1 12 29 25 6 50 13 8913319 7 8 22 81 93 21 24 1 25 32 25 6 50 13 8913320 1 25 93 1 06 24 27 1 17 20 2 6 50 13 8913321 1 1 4 32 1 06 1 18 27 30 1 50 38 EY 10 62 16 8913325 1 1 4 32 1 18 1 34 30 34 1 50 38 E 10 62 16 8913323 1 1 2 38 1 34 1 50 34 38 1 87 47 37 10 62 16 8913327 1 1 2 38 1 50 1 62 38 41 2 12 54 37 10 62 16 8913322 1 3 4 44 1 68 1 81 43 46 2 23 EY 10 62 16 8913324 2 51 1 81 1 98 46 50 2 38 60 E 10 62 16 8913328 2 51 1 98 2 06 50 52 2 50 64 37 10 62 16 8913329 2 51 2 06 2 18 52 56 2 50 64 P d 10 62 16 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 EIN a amp m sales inc p o box 171 chagrin falls ohio 44022 440 708 0180 Innerduct Pulling and Placing Tool Without a doubt the fastest and easiest tool on the market for pulling in
74. dards for safe accurate pulling of fiber optic cables Only our puller can offer load cell torque input for the most accurate tension measuring available Unlike most hydraulic measuring systems this system is not affected by changes in oil temperature component age and power source That means the Fiber Optic Cable Puller does not need to be recalibrated under different weather conditions Standard Features These pullers consist of a 30 762 mm diameter capstan hydraulic motor variable speed foot control manual flow control valve for adjusting maximum speed and a manually adjustable pressure relief valve for adjusting the ultimate pull tension A footage counter is also included Optional Features The Fiber Optic Cable Puller features an optional electronic tension control system with adjustable digital load limits and a load cell tension measuring device Also available Ls a 4 102 nm strip chart recorder incorporated into the electronic control box for a permanent record of the cable pull Components The Fiber Optic pullers are multi component products Order a puller to fit your requirements with combinations of these components Components include Hydraulic puller mounted on a standard 2 1 2 64 mm square tube e 30 762 mm diameter capstan Foot control hydraulic control assembly Electronic control box Chart recorder Battery pack for the tensiometer Hoses and cords to connect the puller to the foot contro
75. dders C Rod Dia in mm 3 16 5 1 4 6 5 16 8 7 16 11 9 16 13 US Thread 1112 24 5 16 18 3 8 16 3 8 16 3 4 10 O Rings 2163600 2215000 Metric Thread 5 8 12 12 M12 O Rings 2163600 2215000 Basket Combination u Used to connect two hand rods pushed into the conduit from opposite ends of a the conduit run Both rods can then be pulled out in one directon Used instead of a swivel coupling when the full length of the rod is dif ficult to push T umm from one end Works in 4 102 mm or larger conduit only Does not negotiate tight bends Rod Dia in mm 3 16 5 1 4 6 5 16 8 7 16 11 9 16 13 US Thread 12 24 5 16 18 3 8 16 3 8 16 3 4 10 Basket Comb 8031400 8031400 8031300 Metric Thread M5 8 12 12 M12 Basket Comb 8033700 8033700 8033700 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Fiberglass Hand Rods Screw together fiberglass duct rods for straight runs All rods equipped with 3 4 10 end fittings which work with 3 4 10 duct rodder accessories 2 500 Ibs 11 120 N pull rating Part Size Number in x ft mm x m 8031923 1 2x 5 12x 1 5 8031922 1 2 x 10 12x3 8032026 5 8 x 5 16x 1 5 8032022 5 8 x 10 16x3 Replacement Brass Hand Rod End Fittings Requires Epoxy 8035851 Part Size in mm 8036021 3 4 10 male end for 1 2 12mm rod 8036022 3 4 10 female end for 1 2 12mm ro
76. draulic and pneumatic controls for ease of operation Ergonomi cally designed No special maintenance required Portability Legs with wheels shown or job Box with wheels Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Fiber Optic Cable Blower Packages Without Electronics With Electronics Package 5 8761330 e Fiber Optic Cable Blower Electronic Controls Blower Leg Kit Common Parts Pack Package 1 8761310 e Fiber Optic Cable Blower Blower Leg Kit Common Parts Pack Requires a minimum of one ii Requires a minimum of one Cable Pack and one Duct Pact Cable Pack and one Duct Pact Package 6 8761335 Fiber Optic Cable Blower Electronic Controls Blower Job Box Common Parts Pack Package 2 8761315 e Fiber Optic Cable Blower Blower Job Box e Common Parts Pack Requires a minimum of one Cable Pack and one Duct Pact J Requires a minimum of one Cable Pack and one Duct Pact Package 7 8761340 Package 3 8761320 Fiber Optic Cable Blower Fiber Optic Cable Blower Electronic Controls i Blower Leg Kit Blower Leg Kit Parts Pack ommon Parts Pac Cable Pack 1 3 Cable Pack 1 3 P Duct Pack 1 3 eDuct Pack 1 3 Package 8 8761345 Package 4 8761325 Fiber Optic Cable Blower e Fiber Optic Cable Blower Electronic Controls Blower
77. eGlider cable pullers are not to be used as a hoist or for lifting supporting or transporting people or loads Complete Pulling Packagesfor CableGlider HD Pulling packages offer cost savings and ordering convenience Part Number 867469 8674689 8674688 Description CableGlider HD Package 1 110 Volt Puller with accessories above e HD Extension frame 600 ft 183 m of 7 8 22mm double braid rope Floor conduit pole mount frame 5 127 mm amp 6 152 mm adapters w retaining fork Running Line Tensiometer CableGlider HD Package 2 Part Number 8674810 All items in Package 1 plus 8674805 Chart recorder for running line tensiometer CableGlider HD Package 3 8674688 All Items in Package 1 plus Amp Type tensiometer Copyright 1992 A amp M Sales Inc CableGlider HD Package 2 Description CableGlider HD Package 4 for export only e 220 Volt Puller with accessories above HD Extension frame 600 ft 183 m of 7 8 22mm double braid rope Floor conduit pole mount frame 5 127 mm amp 6 152 mm adapters w retaining fork Running Line Tensiometer CableGlider HD Package 5 for export only All items in Package 4 plus Chart recorder for running line tensiometer CableGlider HD Package 6 for export only All Items in Package 4 plus Amp Type tensiometer Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Powe
78. eave 20 17 1 2 32 165 71725 Cable Sheave 4 x 20 16 36 lbs 71728 CableSheave 5 x 20 16 1 2 40 Ibs 71721 Cable Sheave 3 x 26 1 2 24 38 Ibs 71724 Cable Sheave 4 x 26 1 2 22 1 2 44 165 71727 CableSheave 5 x 26 1 2 23 56 lbs Cable Sheave Shackle GMP Used for supporting a cable sheave or quadrant block in place at a manhole equipped with pulling in irons The shackle contains a two part clevis made of high strength structural steel with two sets of sheave pin holes 1 3 8 in diameter for accomodating either a cable sheave or a quadrant block The load half has a forged steel hook that attaches to the pulling in irons with a standard 1 2 x 6 foot construction chain while the support half has a shoulder eyebolt so you can tie it off to a support rope over the manhole Each shackle includes a 1 5 16 diameter sheave pin and can withstand working loads of up to 10 000 Ibs This shackle will accomodate any 11 20 or 26 1 2 diameter cable sheave with a 1 3 8 diameter hole size for 3 4 5 cable Make sure that you choose the correct combination shackle and sheave Part Description Sheave Size Weight 71643 Cable Sheave Shackle 3 32 165 71644 Cable Sheave Shackle 4 75 lbs 71645 Cable Sheave Shackle gt 90 Ibs Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Heavy Duty Quadrant Block Condux A series of 6 cast aluminum
79. ecorder for running line tensiometer 8674386 CableGlider Plus Package 3 8674845 CableGlider Plus Package 6 for export only All Items in Package 1 plus All Items in Package 4 plus Amp Type tensiometer Amp Type tensiometer Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 EIN a amp m sales inc p o box 171 chagrin falls ohio 44022 440 708 0180 CableGlider HD Cable Puller The CableGlider HD is specially designed to provide maximum pulling power for longerruns inacompletely self contained unit It offers fast setup portability and is easily adaptable for a variety of pulling situations The removable power pack delivers up to 12 000 pounds 53 375 N of pulling force at low speed over 80 more than our STD puller The two speed motor pulls up to 30 feet per minute at high speed and up to 15 feet per minute at low speed The CableGlider HD comes witha heavy duty frame and extra pivoting arm The front frame height can easily be adjusted with pins CableGlider HD includes the following items e Puller Foot switch Retaining Fork e Conduit Adapters 2 51 mm 3 76 mm 3 1 2 89 mm 4 102 mm Tool box for the accessories CableGlider HD Part Number 8674500 plug 8678075 Description 110 Volt HD Cable Puller with 20 amp twist 220 Volt HD Cable Puller for export only International orders must specify plug Warning Cabl
80. ects of abrasion corrosion prior use or misuse must be considered and the grip replaced when necessary The safety factor is ultimately determined by the user Special Pulling Grips are also available for the stringent requirements of fiber optic applications They feature a special weave that provides positive holding power while allowing the grip to remain flexible ensuring cable protection Each A amp M SALES Kellems pulling grip is designed to work on a specific range of cable diameters and working loads In order to select a grip for your application Estimate the tension to be put on the grip and the working load required Contact A amp M SALES for more assistance in selecting a grip for your application Pulling Grip Selection Chart Grip Style Dual Pull flexibleeye Multiple Strength flexible eye Multiple Strength forged eye K Type grip forged eye T Type grip flexible eye Universal Slack flexibleeye Universal Slack split mesh Application Extra high strength transmission line stringing for bare or insulated conductor and synthetic rope Normal overhead transmission and distribution line stringing for bare or insulated conductor Normal overhead transmission and distribution line stringing for bare or insulated conductor Underground power cables and communication lines Service lines into factories Underground power cables and communication lines Service lines into factories Remove underground cable For pu
81. er quick disconnects low oil shut off and 16 406 mm diameter pneumatic tires Specifications Hydraulic System Open Center Frame Type Two wheel mobile unit Length 35 0 in 889 mm Width 29 0 in 736 mm P Height 32 0 in 812 mm Weight Dry 233 Ibs 105 6 kg Filtration 10 Micron Return Line Canister Type Oil Color Air to Oil Engine Briggs amp Stratton V Twin Vanguard Rated at 16 HP 3 600 RPM Fuel 5 0 gallons 18 9 liters Hydraulic Oil Usable 5 0 gallons 18 9 liters GPM PSI LPM BAR Hydraulic Rated Flow 9 1 0 34 4 0 Part Description 82 2 000 31 0 138 8675200 Hydraulic Power Pack Gas 8675250 Hydraulic Power Pack Diesel Hydraulic Relief 2 150 0 PSI 148 3 BAR Valve Pressure Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 a amp m sales inc p o 171 chagrin falls ohio 44022 440 708 0180 Fiber Optic Cable Blower As a leader in the manufacturing of fiber optic power and CATV cable installa tion tools and equipment Condux offers a superior fiber optic cable blower that is easy to use and safe to operate Our Fiber Optic Cable Blower offers more speed and more push force monitor ing This results in faster installations Install 300 feet of fiber optic cable per minute 90 m min with the new Fiber Optic Cable Blower Our engineers designed the speed in by making the cable travel at the same speed as the air A carrier is always at
82. er Degreaser If you have any Quuestion or would like any additional information about any of these products feel free to call our toll free number New Products From A amp M Sales HP K 24 The most popular non hazardous electrical cleaner degreaser Type HP is available in a new multi pak package e 24 premoistened lint free towelettes in a handy resealable dispenser Convenient safe alternative to bulk packages Economical one step cleaning HP Cleaner Great for shop maintenance use Degreaser HP Cleaner Degreaser A unique and effective Cleaner and Degreaser which is HP K24 W l 7 Non Ozone Depleting and Non Carcinogenic Now available from A amp M Sales Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 EUN a amp m sales inc p o box 171 chagrin falls ohio 44022 440 708 0180 Pulling Grip A amp M SALES Kellems K Pulling Grips are an industry standard for pulling electrical cable bare conductor or rope through conduit systems The grips are made of high quality galvanized steel strand to assure long life and durability Under normal conditions the grips should be used with a safety factor of five but this will vary depending on the situation The tension diameter movement number of objects gripped gripping surface and the attachments used are some of the variables affecting the safety factor In addition the eff
83. ered heads taped in a hand coil The 5 16 8 mm to 9 16 13 mm rod comes with end fittings and a tapered head in a disposable replacement cage Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Cobra Rod Rugged Polymer Jacket Composite Core Braided Reinforcing Wrap Python Rod Rugged Polymer Jacket Composite Core Mini Cobra Rod Rugged Polymer Jacket Composite Core Duct Rod Specifications Duct Rod Min Bending Duct RodDia Pull Strength Core O D Coating O D Radius in mm Ibs n in mm in mm mm 3 16 5 200 890 125 3 2 187 4 8 3 76 1 4 6 350 1 557 187 4 8 250 6 3 5 127 5 16 8 950 4 226 237 6 0 312 7 9 7 178 7 16 11 950 4 226 300 7 6 A37 11 1 11 280 9 16 13 1 400 6 227 375 9 5 500 13 0 11 280 Core D Tolerence Plus Minus 007 Coating D Tolerence Plus Minus 015 Recommended Rod Sizes Conduit Sizes mm 1 2 13 Conduit Sizes mm 3 76 3 1 2 89 4 102 5 127 6 152 amp 203 Recommended Duct Rod Size in mm 3 16 5 3 16 5 3 16 1 4 5 6 3 16 1 4 5 6 1 4 5 16 6 8 1 4 5 16 6 8 1 4 5 16 6 8 Recomended Duct Rod Size in mm 5 16 7 16 9 16 8 11 13 5 16 7 16 9 16 8 11 13 5 16 7 16 9 16 8 11 13 7 16 9 16 11 13 7 16 9 16 11 13 9 16 13 3 4 19 1 25 1 1 4 32 1 1 2 38 2 51 2 1 2 64 Conduit si
84. erous breakage of chains or straps The Jamb Skid is especially useful when there are no pulling in irons available or when the existing irons do not align correctly with the duct opening The Jamb Skid can be placed anywhere within a 360 radius inside the manhole Constructed of solid aluminum the Jamb Skid is both strong and lightweight In most instances it can be installed by one person The complete unit is created by combining a base unit with one of several extension units depending upon the height required Locking 1 1 4 32 mm pins allow the height adjustment of the Jamb Skid Also the width adjusts to accept all Condux sheave assemblies up through 8 203 mm 10 000 Ibs 44 480 N cable tension load rated NOTE Order base section and choice of extension separately for a complete Jamb Skid unit Locking pins coreincluded with the base section Part Manhole Height Range Number Description in mm 8097000 46 1 168 mm Base Section with locking pins 8097001 43 1 092 mm Extension 49 80 1 244 2 032 8097002 76 1 930 mm Extension 78 109 1 981 2 767 8097003 109 2 769 mm Extension 107 138 2 718 3 505 Replacement Pins Part Description 8097040 1 1 4 32 mm diameter pin Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 EIN a amp m sales inc p o box 171 chagrin falls ohio 44022 440 708 0180 Hooked Hanger Sheaves Condux Tie off in the
85. ess steel construction provides a smooth non chafing cable placement surface This quadrant can be used either inside the vault or on the edge of the manhole This unit has an 18 bending radius and is compatible with all fiber optic cables up to 7 8 in diameter The Fiber Optic Quadrant Block when used in the manhole is mounted with a GMP Fiber Optic Shackle or a pulling Frame Part Description Weight 15316 Fiber Optic Quadrant Block 18 Ibs 8 oz Fiber Optic Shackle GMP The Fiber Optic Shackle when secured to the pulling irons will allow you to mount up to two Fiber Optic Quadrants for ease of cable Placement This light weight all aluminum shackle provides a maximum load strength of 3 000 Ibs The shackle is made of two U shaped members each of which has a seperate swiveling safety hook on one end Both members are joined by a special bushing An L shaped locking pin included 1 5 16 diameter fits through this bushing to support both quadrants or sheaves To change add or remove a quadrant or sheave all you have to do is remove the locking pin the shackle stays together A knurled knob is attached to the shackle by a wire rope that lets you open it on one side for easy removal even when there is a continuous section of cable running through the shackle Two self storing spacers come with each shackle to securely hold a single quadrant or sheave in place When you want to use more than one quadrant you can stow the spacers on one end of
86. grin falls ohio 44022 440 708 0180 Single Offset Eye Grip This grip works identically to the U Bail grip except that the grip eye is offset for off center pulls This grip is made of uncoated galvanized aircraft strand steel for long life and safety Part Working Breaking m ee ee eee Number M in E in Grip Size Load Strength E 25 6 a 1 4 3 8 500 lbs 1 000 Ibs i FO 37 OE 6 6 1 4 1 2 500 Ibs 1 000 Ibs FO 50 OE 6 6 1 2 5 8 600 Ibs 1 250 Ibs FO 62 OE 6 1 5 8 3 4 600 Ibs 1 250 Ibs FO 75 OE 6 2 3 4 1 750 Ibs 1 500 165 M M i e M FO 100 OE 6 8 1 1 1 4 750 Ibs 1 500 Ibs Pulling Grips Cable Approx Junior Grip Part Diameter Breaking E in M in Number Range In Strength Lbs ON Im M E 033 05 011 0 19 0 24 400 3 1 4 4 1 4 i JL25 0 25 0 36 450 3 1 4 4 1 4 M 7e JL37 0 37 0 49 900 3 3 4 7 JL50 0 50 0 61 1 300 4 1 4 8 1 2 Mesh length at nominal diameter Mi 2 m JL75 0 75 0 99 2 800 5 3 4 10 JL100 1 00 1 24 3 900 6 1 2 11 1 2 Junior Grip Kit The best Small Grip Kit on the market This kit includes some of the most widely used grips used for pulling fiber and small cables all included in a carrying case for ease of transport and storage Cable Approx Part Diameter Breaking E In M In Number Range In Strength Lbs Junior Grip Kit JL25 0 25 0 36 450 3 1 4 4 1 4 JLKIT JL37 0 37 0 49 900 3
87. haft Part Diameter Flat Width Max Cable O D Number in mm in mm in mm 10727 7 1 4 184 8 204 8675213 12 305 9 229 8675230 30 762 4 102 12 19 8675430 30 762 8 203 1 00 25 30540 40 1 020 8 203 8675220 50 1 270 8 203 1 25 32 Not to be used for fiber optic cable or steel rope Intended for pulling innerduct power telephone or coaxial cables Mounting Sockets Floor Socket Mount The Fiber Optic Cable Puller has a square mounting post 2 1 2 64mm x 2 1 2 64mm A female mounting socket is required for stability during cable pulling operations Part Description 2260800 Floor Socket Mount Cast 2260900 Overhanging Socket Mount Cast Base Mount 8675130 Base Mount 8675138 Side Mount Side Mount Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 amp m sales inc 171 chagrin falls ohio 44022 440 708 0180 Calibration Dynamometer The Fiber Optic Cable Puller is calibrated at the factory prior to shipment The Calibration Dynamometer is used to check that the puller s calibration has not changed especially if the relief valve has been adjusted in the field On cable puller models equipped with an Electronic Control box the Calibration Dynamometer simply verifies the readings Other load capacities available Part Description 2261000 1 000 Ib 454 kg Calibration Dynamometer Optional Electronic Co
88. ible Guide Part Diameter Length Number in mm ft m 8931503 2 5 3 9 8931506 2 5 6 1 8 8931509 2 5 9 27 i a Extensions Includes Mounting Bolts 8934503 4 102 3 9 8934506 4 102 6 1 8 8934509 4 102 6 1 8 8934512 4 102 12 3 6 8935503 5 127 3 9 8935506 5 127 6 1 8 8935509 5 127 9 277 8935512 5 127 12 3 6 8936503 6 152 3 9 1 8936506 6 152 6 1 8 8936509 6 152 9 27 8936512 6 152 12 3 6 8988503 8 203 3 9 8988506 8 203 6 1 8 8988509 8 203 9 27 8988512 8 203 12 3 6 Copyright 1992 amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 amp m sales inc p o 171 chagrin falls ohio 44022 440 708 0180 Close Clearance Flexible Cable Guides For guiding cable from the reel into the duct The cable feeds through the bell adapter and exits through the duct adapter which fits into the duct Duct adapters ordered separately Other lengths availalble upon request Flexible Cable Flexible Cable Part Diameter Length Number in mm ft m 8040109 4 102 9 228 8041009 5 127 9 228 3 8044509 6 152 9 228 Extensions 5 Flexible Cable Flexible Cable Part Diameter Length Number in mm ft m 8040203 4 102 3 1 2 eN 8041103 5 127 3 1 2 3 4 8044603 6 152 3 1 2 3 7 Steel Duct Adapters Duct Adapter Duct Size Part Diameter Length Number in mm ft m Style 8040300 4 102 3 76 Round 8040400 4 102 3 1 4 83 Round 8040600 4 102 3 1 2 89 Roun
89. l assembly and electronic control box WARNING The Fiber Optic Cable Puller is not to be used as a hoist or for lifting supporting or transporting people or loads Variable Speed Foot Control Like the accelerator pedal in your car or truck the Variable Speed Foot Control allows the operator to easily manage the speed of the pull Bi directional Pulling Bi directional pulling capabilities means less set up time and more productivity Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 EIN a amp m sales inc p o box 171 chagrin falls ohio 44022 440 708 0180 Specifications 12 in 305 mm 30 in 762 mm 50 in 1270 mm Diameter Capstan Diameter Capstan Diameter Capstan Pulling Force Ibs KN Ibs kN Ibs kN Maximum 2 000 8 9 1 000 4 4 600 2 1 Continuous 2 000 8 9 1 000 4 4 600 2 1 Pulling Speed ft min m min ft min m min ft min m min No Load 93 9 28 6 240 0 73 2 391 4 119 3 At Maximum Force 93 9 28 6 240 0 73 2 391 4 119 3 Power Requirements Pressure 2 000 to 2 500 psi 137 to 172 bar Flow 6 to 10 gpm 22 7 to 37 9 Ipm Peak Power 8 HP 5 97 kW Fiber Optic Cable Puller Packages Package l Fiber Optic Cable Puller r Standard ordering package includes items listed below Puller package does not 1 id include remote mounting stand a base mount please order separately WG t Part Description a i j i 8690000 Fiber Optic Cable Puller Package
90. l A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 op TRE Pole Mounting Frame ECNE ENT When overhead fiber optic cable installation applications require the smooth hydraulic d power and accurate tension measuring system of the Fiber Optic Cable Puller the Pole HN Mounting Frame is available Install the cable puller on the frame with no modifica tions necessary to the puller By design the Pole Mounting Frame offers a secure hold on the cable puller both vertically and horizontally for a worry free pull A special plug drives into wood poles for added stcibility Includes all mounting hardware Rr Part Description Es ie 8676000 Pole Mounting Frame aaa and Hardware Mounting Stand For fiber optic cable pulling applications that demand flexibility in setup the Remote Mounting Stand allows positioning of the cable puller well away from the power source Easy to set up the unit is both sturdy and compact Features 2 1 2 64 mm square mount to accommodate any Fiber Optic Cable Puller Part Description 8675115 Remote Mounting Stand Capstans To conform to the many specifications of fiber optic cable available and to offer more cable pulling capabilities A amp M offers several sizes of capstans that fit the Fiber Optic Cable Puller These bayonet style capstans are offered in 12 305 mm 30 762 mm and 50 1 270 mm diameters for a standard 2 7 16 diameter AT amp T bayonet style s
91. length for maximum JL 62 FO CM 24 2 Sg aA 750 lbs 1 500 Ibs gripping surface JL 75 FO CM 24 8 1 900 lbs 1 800 Ibs JL 100 FO CM 24 8 1 1 1 4 900 Ibs 1 800 165 Split Lace This grip has the same long life easy pulling characteristics as the closed mesh grip but is for use on any phase of suspension or pulling when a conductor end is not available This grip can also be used for middle of the run applications The lacing is made of coated steel flexible lacing cable Part Number M in E in Grip Size Working Load Breaking Strength JL 25 FO SL 24 8 1 4 3 8 500 165 1 200 lbs JL 37 FO SL 24 8 1 4 1 2 500 Ibs 1 200 lbs JL 50 FO SL 24 8 1 2 5 8 750 165 1 500 165 JL 62 FO SL 24 8 5 8 3 4 750 Ibs 1 500 165 JL 75 FO SL 24 8 3 4 1 900 Ibs 1 800 Ibs JL 100 FO SL 24 8 1 1 1 4 900 Ibs 1 800 165 Split Rod Use this grip as you would the Split Lace Grip for middle of the run applications or when neither end of the conductor is available Same 24 mesh length for maximum gripping surface same continuous single weave through the eye for even pulling tension The rod and eyelets are made of HI Strength steel for durable service Part Number M n Ec in Grip Size Working Load Breaking Strength JL 25 FO SR 24 8 1 4 3 8 600 Ibs 1 200 165 JL 37 FO SR 24 8 1 4 1 2 600 Ibs 1 200 Ibs JL 50 FO SR 24 8 1 2 5 8 750 Ibs 1 500
92. les Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Dua Pull Feed Tube Feed Tube Part For Use With Rope Diameter Length Number Description Dua Pull Grip in mm in imn 08641610 091 06 1043 08641710 25 65 6 17 28 711 08641616 091 06 1044 08641716 50 90 13 23 40 1 016 08641628 091 06 1045 08641728 75 1 10 19 28 52 1 321 08641634 091 06 1046 08641734 1 00 1 50 25 38 67 1 702 08641640 091 06 1047 08641740 1 25 1 70 32 43 83 2 108 08641646 091 06 1048 08641746 1 50 2 10 38 53 96 2 438 Support Grip A amp M SALES Kellems Support Grips are used to hold the weight of electrical cable as it hangs in a vertical sloping or horizontal position The grips are made of high grade non magnetic tin coated bronze strand Electrical cable must be supported or its dead weight can cause excessive strain or pullout at the connections resulting in power failure Support grips also absorb additional strain from flexure vibration expansion and contraction Fiber Optic Support Grips available from A amp M SALES are specially designed to provide fiber optic cable support easily and GripStyle Application economically Closed Mesh Permanent support cable end available Split Mesh Permanent support cable end unavailable Each A amp M SALES Kellems Support Grip is designed to work on a lace closing specific range of cable diameters and working load Contact A amp M Split Mesh Temporary sup
93. ll A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Flexible Cable Guide with Aluminum Adapters Cable feeds through the bell adapter and exits through the duct adapter which fits into the duct Bell adapter and duct adapter included for specific duct and guide size ordered Other lengths available upon request Flexible Guide Flexible Guide Part Diameter Length Number in mm ft m NE 8931009 2 51 9 2 7 8931012 2 51 12 3 6 8934009 4 102 9 27 8934012 4 102 12 3 6 6935009 5 127 9 2 1 8935012 5 127 12 3 6 8936009 6 152 9 2 7 8936012 6 152 12 3 6 8988009 8 203 9 8988012 8 203 12 3 6 Duct Adapter l Bell Adapter Flexible Guide Flexible Guide mt Part Diameter Length E Number in mm ft m em d 8960200 2 31 Innerduct _ 8931010 2 51 1 25 8931013 2 51 1 4 3 A DuctAdapter 8931015 2 51 A 38 mre 8931020 2 51 2 51 8934020 4 102 2 51 8934030 4 102 3 76 Bell Adapter Includes Mounting Bolts 8934035 4 102 3 1 2 89 Part Size 8934040 4 102 4 102 Nahar in mm 8935020 5 127 2 51 8931000 51 8935030 5 127 3 76 8934000 4 102 8935035 5 127 3 1 2 89 8935000 5 127 8935040 5 127 4 102 8936000 6 152 8935050 5 127 5 127 8988000 g 203 8935060 5 127 6 152 8936040 6 152 4 102 Included with cable guide unit above for that specific duct size d fos 3 is 8936060 6 152 6 152 Tapered and threaded to fit over 1 2 innerduct 8988080 203 203 Flexible Guide Flex
94. lling slack in final placement of new cable when end of cable 1s available Remove underground cable For pulling slack in final placement of new cable when end of cable is not available Remove underground cable For pulling slack in final placement of new cable when rod rod closing closing end of cable is not available With rod closing for quick installation Light pulling underground electrical construction Industrial plant wiring and rewiring jobs 0 Connect bundled insulated building wire to a pulling tape Pull wire through conduit 7 Universal Slack split mesh Light Duty flexible eye Junior flexibleeye Calculating grip sizefor multiple cables with the same diameter Number of Cables Grip 2o omo wa ma 28 2 19 24 12 25 1 25 1 49 1 50 1 74 38 44 31 36 27 31 24 29 22 20 1 75 1 99 4 44 59 36 49 31 42 29 38 26 34 2 75 3 06 77 188 60 69 88 110 77 96 69 86 1 76 1 98 1 54 1 74 1 37 1 55 1 98 2 20 89 1 02 1 02 1 28 1 28 1 53 1 53 1 79 1 79 2 05 2 05 2 30 2 30 2 56 59 75 49 63 34 43 75 90 63 76 65 77_ 58 67 52 60 69 2 00 2 49 2 50 2 99 3 00 3 49 1 74 1 93 1 55 1 72 1 39 1 55 1 27 1 41 4 50 4 99 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 700 57 Fiber O
95. meter Breaking E In M ln D in T Number Range In Strength po 033 29 1007 0 10 0 22 1 000 4 9 0 9 033 29 1008 0 21 0 35 1 500 4 14 0 9 E 033 209 1009 0 32 0 48 2 200 4 18 0 9 G 033 29 1010 0 42 0 61 2 800 4 21 0 9 033 29 1011 0 53 0 74 3 300 45 24 1 3 033 29 1012 0 64 0 87 45 27 1 3 Fiber Optic Slack Grip Slit Mesh Rod Closing Single Weave Cable Approx Part Diameter Breaking E In M In Number Range In Strength Lbs 033 29 1015 0 25 0 37 300 3 033 209 1016 0 38 0 49 800 3 5 033 29 1017 0 50 0 61 800 3 7 5 033 29 1018 0 62 0 74 1 200 3 8 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 a amp m sales inc p o 171 chagrin falls ohio 44022 440 708 0180 Closed Mesh This grip is especially designed for long pulls It features a continuous single weave ppe e design that provides an even pull from the receiving end through the pulling eye The 9 09 9 9 9 09 9 9 9 9 0 0 0 0 0 0 0 0 0 0 0 0 0 9 OO Sn S LAA AN RELIG SSS SS GS OS on cum Part Number M in E in Grip Size Working Load Breaking Strength MM JL 25 FO CM 24 8 1 4 3 8 600 Ibs 1 200 Ibs grip is fabricated of coated galvanized JL 37 FO CM 24 Q l 4 12 600 Ibs 1 200 Ibs aircraft strand for long life and safety Each JL 50 FO CM 24 gn 1 27 5 g 750 lbs 1 500 Ibs grip has a 24 mesh
96. mple storage is built in and all doors and openings have locks for security At the job site any cable puller can be set in the left center or right positions on the trailer bed These three built in cable puller mounts provide a total of seven cable pulling positions A remote mounting stand is incorporated into the center position to provide a travel mount for the puller It also detaches for use away from the trailer Power for the cable puller is provided by an integrated gasoline or diesel driven Briggs amp Stratton 18 HP 13 4 kW hydraulic power unit Gasoline Part Description 8675820 Trailer includes gasoline driven hydraulic power unit gas tank 4 leveling jacks 2 wheel chocks and remote mounting stand 8675821 Trailer with Fiber Optic Cable Puller pkg 1 8675822 Trailer with Fiber Optic Cable Puller pkg 2 8675823 Trailer with Fiber Optic Cable Puller pkg 3 Diesel Part Description 8675620 Trailer includes gasoline driven hydraulic power unit gas tank 4 leveling jacks 2 wheel chocks and remote mounting stand 8675621 Trailer with Fiber Optic Cable Puller pkg 1 7 8675622 Trailer with Fiber Optic Cable Puller pkg 2 6675623 Trailer with Fiber Optic Cable Puller pkg 3 For information on Fiber Optic Cable Puller Packages see previous pages For Specifications on Fiber Optic Cable Trailer Please Call Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466
97. nd bends sweeps and duct misalignments P 5 16 8mm to 9 16 13mm Rod Dia in mm 3 16 5 1 4 6 5 16 8 7 16 11 9 16 13 USC Thread 12 24 5 16 18 3 8 16 3 8 16 3 4 10 Flexible Leader 8033428 8033443 8037538 8037538 8037534 Metric Thread M5 M8 M12 M12 M12 3 16 5mm to 1 4 6mm Flexible Leader 8033448 8033444 8037512 8037512 8037512 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Mini Harness x Screws onto the threaded end fitting to allow for easy wire attachment when cC pulling wire into conduit m O O OOO RodDia in mm 3 16 5 1 4 6 5 16 8 7 16 11 9 16 13 USC Thread 12 24 5 16 18 3 8 16 3 8 16 3 4 10 Mini Harness 8033433 8033434 8033435 8033435 8033436 Metric Thread M5 M8 M12 M12 M12 Mini Harness 8033432 8033431 8033437 8033437 8033437 Roller Guide 5 16 8mm to 9 16 13mm Helps guide the duct rod around bends sweeps and duct misalignments Also used when the conduit is already occupied by other cables 3 16 Smm to 1 4 6mm Rod Dia in mm 3 16 5 1 4 6 5 16 8 7 16 11 9 16 13 USC Thread 12 24 5 16 18 3 8 16 3 8 16 3 4 10 Roller Guide 8037430 8037440 8037401 8037401 8037400 Metric Thread 5 Ms M12 M12 M12 Accessory Kit 8037428 8037450 8037405 8037405 8037405 Swivel Coupling Used to connect two duct rods pushed into the conduit from the same end Used when one length of duct rod is not long eno
98. ntrol System The electronic control system in a Fiber Optic Cable Puller directly measures the rotational torque at the motor thereby indicating actual cable pulling forces It is the most accurate technology available for measuring pull tension True Measurement Better Control Not affected by oil temperature power source or component age Does not require recalibration from job to job The Control Box features analog and LED tension displays and an easy to use membrane switch control panel Program the maximum tension your cable will allow and the cable puller will be shut off if that tension is reached The Control Box may run off a 12 volt vehicle battery or the supplied battery pack The optional Chart Recorder provides you with permanent documentation of each pull for your records Fiber Optic Cable Puller Trailer A portable self contained cable pulling system incorporating a gasoline or diesel driven hydraulic power source cable puller mounts leveling and stabilizing hardware and lockable storage areas Designed with the Fiber Optic Cable Puller in mind the Fiber Optic Cable Puller Trailer can handle the stress of pulling 2 000 Ibs 8 896 N of line tension and offers a multitude of cable puller positions The unit is light and easily transported by a standard pickup truck The rear compartment slides forward to uncover the working platform controls for the power unit are easily accessed for operator convenience A
99. opes and has an elongation of less than 10 compared to Polypropylene rope which is 20964 Not available printed Other lengths available Part Break Strength Approx Width Length Number in mm in mm ft m 8099703 1 130 5 026 1 2 13 3 000 914 Conduit Measuring Tape For pulling fiber optic or coaxial cable through innerduct or for determining exact wall to wall measurements in duct runs Other strengths and lengths are avail able Part Break Strength Approx Width Length Number in mm in mm ft m 8073900 150 578 3 16 5 3 000 914 Pallet quantities of 48 available Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 EN a amp m sales inc p o box 171 chagrin falls ohio 44022 440 708 0180 Wood Test Mandrels Pull through duct to prove joint integrity and test for out of round duct 2 240 Ibs 9 964 p N N load capacity Wood body with steel end caps and pulling eyes au y Body Part Duct Size Length Max O D Number in mm in mm in mm 8020660 4 102 6 152 3 56 90 8020600 4 102 11 1 2 292 3 56 90 Aluminum Test Mandrels Pull through duct to prove joint integrity and test for out of round duct Provides an 80 fill in schedule 40 and telephone conduit Body Load Part Duct Size Length Max O D Capacity Number in mm n mm ft m Ibs N 8059515 1 1 2 38 1 74 44 1 18 30 2 200 9 786 8059520 2 51 2 40 61 1 62 4 2 2
100. ounting Stand or Mounting Sockets Fiber Optic Sheave Mount Components Part Description 8637900 Adjustable Sheave Mount Head includes sheave mounting shaft and pins 8637909 18 457 mm Center Tube Mount 8637910 32 812 mm Center Tube Mount 8637911 48 1220 mm Center Tube Mount 8637912 Fiber Optic Sheave Mount Assembly 8637743 Fiber Optic Aluminum Hanger Sheave 3 x 24 76 x 610 mm 8675115 Fiber Optic Puller Remote Mounting Stand Assembly Replacement Sheaves are available Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Eu a amp m sales inc p o box 171 chagrin falls ohio 44022 440 708 0180 Fiber Optic Sheave Mount Packages Part Description 8637930 Adjustable Fiber Optic Sheave Mount Pkg 1 Includes Mounting Head all three mounting tubes sheave and sheave arm assembly 8637940 Adjustable Fiber Optic Sheave Mount Pkg 2 Includes Mounting Head all three mounting tubes and sheave 8637950 Adjustable Fiber Optic Sheave Mount Pkg 3 Includes Mounting Head and all three mounting tubes Fiber Optic Sheave Mount Package 3 Package 2 Fiber Optic Sheave Mounting Stand Fiber Optic Sheave Mounting Stand with Sheave Arm Assembly Sheave at 45 Angle iX 7d Fiber Optic Sheave Mounting Stand Sheave Vertical Fiber Optic Sheave Mounting Stand Sheave Horizontal Copyright 1992 A amp M Sales Inc Ca
101. placement Cages Use A amp M Sales Replacement Cages to update older cages or to replace damaged cages Fits all major manufacturers fiberglass rods Make sure that you choose the right size cage for the rod that you are using Available sizes 16 24 30 and 45 If you need help in determining the correct size cage feel free to contact us on our toll free line for help in deciding what cage may suit your needs best RodDia in mm 3 16 5 1 4 6 5 16 8 7 16 11 9 16 13 ReplacementCage 8081516 8081524 8081530 8081550 8081550 Cage Diameter 16 406 24 610 30 762 45 1 143 45 1 143 16 Cage 24 Cage 30 Cage Fiberglass Duct Rodding Units CS Kits come complete with NON CONDUCTIVE TOOLS ea Self Feeding Frisbee Type Reel 100 or 165 3 ea Spring Ball Leaders 1 4 3 8 and 1 2 2 ea Brass Pulling Eyes ea Cable Grip with Eye ea Bottle of Pulling Lube ea Pulling Plier REPAIRITEMS 3 ea Glue On Rod Ends 2 ea Brass Splices lea Small Bottle Of Glue Part Description 44100 1 8 x 100 Coated Rod Rod amp Dispenser Only 44100 CS 1 8 x 100 Coated Rod with Carrying Case 44165 1 8 x 165 Coated Rod Rod amp Dispenser Only 44165 CS 1 8 x 165 Coated Rod with Carrying Case All items are packed in a Brief case 15 x 16 x 3 Weight 4 Ibs Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 EIN a amp m sales inc p o bo
102. port cable end unavailable SALES for more assistance in selecting a grip for your application Support Grip Selection Chart rod closing Slack Grip Split Mesh Rod Closing Cable Approx Part Diameter Breaking E In M In Number Range in Strength 165 033 10 001 0 50 0 61 1 500 7 6 033 10 002 0 62 0 74 1 800 7 8 A 033 10 003 0 75 0 99 2 200 7 10 M q EB c 033 10 004 1 00 1 24 3 400 8 12 SCS i 033 10 005 1 25 1 49 4 500 8 14 xe SS 033 10 006 1 50 1 74 5 800 9 15 E Eye length mier 033 10 007 1 75 1 99 7 600 10 16 Mesh length at nominal diameter 033 10 008 2 00 2 49 9 000 10 19 033 10 009 2 50 2 99 11 000 10 20 033 10 010 3 00 3 49 12 000 12 21 033 10 011 3 50 3 99 12 000 12 24 Cable Approx Slack Grip Split Mesh Lace Closing Pari Diameter Breaking Ed Mdm Number Range in Strength Ibs 033 09 003 0 75 0 99 2 500 7 12 033 09 004 1 00 1 24 3 500 8 15 033 09 005 1 25 1 49 4 000 8 16 M 4 033 09 006 1 50 1 74 4 000 9 17 ca 033 09 007 1 75 1 99 4 000 10 18 COCOA 033 09 008 2 00 2 49 4 000 10 19 E Eye length 1 033 09 009 2 50 2 99 4 000 10 20 Mesh length at nominal diameter 033 09 015 1 50 1 99 4 000 9 5 033 09 016 2 00 2 49 4 000 10 26 033 09 017 2 50 2 99 4 000 10 29 033 09 018 3 00 3 49 4 000 12 32 033 09 019 3 50 3 99 4 000 12 35 Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800
103. ptic Pulling Grips Fiber Optic Grip Flexible Eye Low Profile Double Single Weave Mesh Double Single weave mesh galvanized steel for outside plant cable Used for the installation of fiber optic communicaton lines either underground overhead through condiut or through enclosures They will fit single cables or cable bundles are easily installed on the cable and are reusable N 6 Cable Diameter Approximate Breaking Part Range Strength E M Number Description in mm in mm in mm n mm 08643753 033 29 1193 10 22 3 6 900 4 003 71 2 190 10 254 08643754 033 29 1194 21 35 5 0 1 400 6 227 71 2 190 14 356 08643755 033 29 1195 32 48 8 12 2 000 8 896 31 2 216 19 483 08643756 033 29 1196 42 61 11 15 2500 11 120 81 2 216 21 533 08643757 033 29 1197 53 74 13 19 3000 13 344 81 2 216 2 584 08643758 033 29 1198 64 87 16 22 4200 18 682 81 2 216 25 635 08643759 033 29 1199 75 1 00 19 25 4200 18 682 81 2 216 28 711 Fiber Optic Grip Flexible Eye Cable Approx Part Diameter Breaking E In M In D In Number Range In Strength A M 033 29 1000 0 10 0 22 1 000 5 5 9 0 8 Y 033 29 1001 0 21 0 35 1 500 3 9 14 0 8 e ncs 2 033 29 1002 0 32 0 48 2 200 6 18 0 9 OO OC OO OO Se 57 ae SSS 033 29 1003 0 42 0 61 2 800 6 2 0 9 033 29 1004 0 53 0 74 3 300 6 5 24 13 D 033 29 1005 0 64 0 87 4 700 6 5 2 1 3 7 0 Fiber Optic Grip Swivel Eye Part Dia
104. r Dart Hose Part Description v 8039300 25 7 6 m x 2 1 2 64 mm heavy duty hose 6039301 Replacement hose end fitting Seal Off 1 2 1 1 4 13 32 mm Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 Power Dart Blower Accessory Bag Convenient canvas bag holds power dart hose Inner bag holds line carriers foam carriers seal off body and seal offs Part Description 8030060 Power Dart Blower Accessory Bag Carrier Kit For Power Dart Blowers A convenient way to order a practical assortment of carriers and seal off products for use with the Power Dart Blower or other applications Kit includes the following Duct Size Item in mm Power Dart Blower Seal Off 1 1 2 2 1 2 38 64 Power Dart Blower Seal Off 2 1 2 6 64 152 Power Dart Seal Off Body 1 2 6 13 152 Line Carrier 2 51 Line Carrier 4 102 Inflatable Carrier 1 1 2_2 1 2 38 64 Infaltable Carrier 3 4 76 102 Duct Projectile 2 50 Duct Projectile 4 102 Part Description 8030011 Carrier Kit for Power Dart Blowers Foam Carrier Part Duct Size Max O D Lightweight carrier easily blows through duct Best suited Number in mm in mm for short runs and runs with multiple bends MUN B E gt 8078300 3 4 19 Mis 19 8032200 1 29 1 00 25 8032300 1 1 4 25 32 8033600 30 30 8039300 1 1 2 38 1 50 38 8033500 45 45 8032400 2 51 2 00 51 8033800 60 60 8078400 2 1 2 64 2 50 64 8032500 3 76 3 00 76 8033900
105. r Packs As an added measure of versatility and convenience the CableGlider Power Packs can be puchased separately without the standard base frames provided with the CableGlider Cable Pullers The power packs provide the same pulling capacities as the CableGlider Cable Pullers and can be used on the Floor Mount Frame or the Floor Conduit Pole Mount Frames WARNING CableGlider cable pullers are not to be used as a hoist or for lifting supporting or transporting people or loads Part Description 8610860 110 Volt STD amp Plus Cable Puller Power pack 8678000 220 Volt STD amp Plus Cable Puller Power pack for export only 8674680 110 Volt HD Cable Puller Power pack 8678010 220 Volt HD Cable Puller Power pack for export only Adjustable Manhole Adapter Designed to work with CableGlider Cable Pullers the Adjustable Manhole Adapter allows greater stability and versatility for manhole pulls The rugged steel frame provides an adjustable platform to fit 18 450 mm to 34 850 mm manholes Use the frame to position a cable puller above a manhole Installation is easy the fit is secure and the strength is amaximum 12 000 lbs 53 376 N Requires 6 retaining fork Part Description 8674690 Adjustable Manhole Adapter g Floor Mount Frame Fastens to the floor of vault manhole or utility room The power pack pins easily to the frame Requires 5 8 or M16 fasteners grade 5 or better WARNING
106. rackets may be used e Approx weight is 5 5 lbs 2 5 kg per foot of length e Twisted hook is an integral part of side rail Part e Approx weight is 5 lbs 2 3 kg per foot of length Number Description tluough 12 feet 3 7 m 8381901 Manhole Ladder wall mount 6 5 2 0 m long Approx weight is 7 6 Ibs 3 4 kg per foot of length 382101 Manhole Ladder wall mount 3 0 24 m long over 12 feet 5 7 m 8382201 Manhole Ladder wall mount 9 0 2 7 m long 8382301 Manhole Ladder wall mount 10 0 3 0 m long rae Bescoppon 8382401 Manhole Ladder wall mount 11 0 3 4 m long ME Ladder 30 1 7 m Tong 8382501 Manhole Ladder wall mount 12 0 3 7 m long d 8382601 Manhole Ladder wall mount 13 0 4 0 m long 6382000 Manhole Ladder D 2 1 m long 8382701 Manhole Ladder wall mount 14 0 4 3 m long 8382801 Manhole Ladder wall mount 15 0 4 6 m long Manhole Ladder 20 27 m 8382901 Manhole Ladder wall mount 16 0 4 9 m long aea Matadia Dadder AU 8384101 Manhole Ladder wall mount 18 0 5 5 m long Manaole 8384201 Manhole Ladder wall mount 20 0 6 1 m long Manhole Ladder 12 0 3 7 m long 8384001 Manhole Ladder wall mount 22 0 6 7 m long 3382600 Manhole Ladder 13 0 4 0 m long 8382700 Manhole Ladder 14 0 4 3 m long 3382800 Manhole Ladder 15 0 4 6 m long 8382900 Manhole Ladder 16 0 4 9 m long 8384100 Manhole Ladder
107. red Head variations are DLE pictured SE or U Please specify head desired Working loads as listed in the table below are maximum holding power for the smallest conductor in each size range Cable Approx aa Cable Approx Part Diameter Breaking UE I Part Diameter Breaking Number Range In Strength Lbs Number Range In Strength Lbs SR 75 75 1 00 6 000 TN LSR2 50 2 50 3 00 15 000 75 1 00 6 000 Y LSL2 50 2 50 3 00 17 000 LSR1 00 1 00 1 25 7 500 A LSR3 00 3 00 3 50 17 000 LSL1 00 1 00 1 25 7 500 nN LSL3 00 3 00 3 50 17 000 LSR1 25 1 25 1 50 9 000 LSR3 50 3 50 4 00 17 000 LSL1 25 1 25 1 50 9 000 LSL3 50 3 50 4 00 18 000 LSR1 50 1 50 1 75 11 000 LSR4 00 4 00 4 50 20 000 LSL1 50 1 50 1 75 11 000 Wy i LSL4 00 4 00 4 50 20 000 LSR1 75 1 75 2 00 13 000 LSR4 50 4 50 5 00 22 500 LSL1 75 1 75 2 00 13 000 Ve LSL4 50 4 50 5 00 22 500 LSR2 00 2 00 2 50 15 000 We 1565 00 5 00 5 50 25 000 LSL2 00 2 00 2 50 15 000 LSL5 00 5 00 5 50 25 000 Flex Eye Multi Grips For support and pulling of different size cables from one flexible eye This gives complete support for each conductor where support ing a bundle is not desirable Used in conjunction where severe vibration may be encountered 1 e mine shaft industrial adjacent to heavily traveled freeways When ordering please give sizes and number of conductors to be supported Theseunits can be
108. rown 0 50 0 74 10 000 9 32 5 16 ET ok Nc 033 02 048 Light Blue 0 75 0 99 14 400 11 41 3 6 033 02 050 Gold 1 00 1 24 24 600 12 52 1 2 A 033 02 052 Black 1 25 1 49 30 600 12 56 1 2 EEE i 033 02 054 Red 1 50 1 74 30 600 12 60 E Eye length i 033 02 056 Dark Blue 1 75 1 99 48 000 18 70 5 8 Mesh length at nominal diameter 033 02 1078 Yellow 2 00 2 49 48 000 18 50 5 8 033 02 1079 Orange 2 50 2 99 48 000 18 52 5 8 033 02 1080 Aluminum 3 00 3 49 48 000 18 54 5 8 033 02 1081 Lt Green 3 50 3 99 48 000 18 56 5 8 Non Conductive Grip Non Conductve Pulling Grips are made of a high strength non conductive aramid fiber and are available for pulling single cable or cable bundles Their braided double weave design adds strength and positive holding power They were developed for use by utilities for pulling overhead distribution lines in close proximity to energized lines and hardware Cable Diameter Breaking Part Range Strength A C Number Description Color in MM N n mm in mmy in mm 08642422 036 28 001 Green 50 62 13 16 4 00017 792 551 40 240 610 08642428 036 28 002 Yellow 63 74 16 19 5 00022 240 551 40 260 660 08642431 036 28 003 75 99 19 25 6 00026 688 601 52 310 787 63 16 08642437 036 28 004 Blue 1 00 1 24 25 31 6 00026 688 651 65 36 0 914 63 16 08642443 036 28 005 Wlute 1 25 1 49 32 38 6 00026 688 6 71 70 415 1 054 63 16 Copyright 1992 A amp M Sa
109. s are available Clevis Head Standard Head and Swivel Head NOTE When properly installed all Reusable Power Pulling Eyes will exceed the recommended maximum pulling tensions for single conductor power cable as specified by the cable manufacturer Multiple Pulling Harness and connectors available Reusable Eyes are color coded for ease of use NOTE NOTE MAP Reusable Power Pulling Eyes Clevis Head The Clevis Head Power Pulling Eyes feature a slotted head with clevis pin to allow direct attachment to the multiple pulling harness When pulling multiple cables into a single conduit the conductors can be attached to a harness and installation is simplified to a single pull of one assembly Each Clevis Head Power Pulling Eye includes a clevis socket sleeve nut and plug TM EL arae mA WI Max Diameter Max Eye O D Slot Width Slot Depth Pin Dia Pin Center Part Cable Diameter A B C D E Number Size Color in mm in mm in mm in mm in mm in mm 8917750 1750 kcmil Yellow 1 526 39 2 50 64 1 00 25 2 80 71 88 22 1 23 31 8917950 1500 Black 1412 36 2 38 60 19 1 78 45 63 16 2 18 8917850 1250 kemil Blue 1 289 33 2 25 57 75 19 1 78 45 63 16 T2 18 8917150 1000 kcmil Orange 1 152 29 2 06 52 J3 19 1 78 45 63 16 N 18 8917250 750 kcmil Brown 998 23 1 175 44 63 16 1 59 40 56 14 78 20 8917350 700 kcmil Gray 964 24 1 75 44 63 16 1 59 40 56 14 78 20 8917450 500 Yellow 8
110. s includes the following items e Puller Foot switch Retaining Fork e Conduit Adapters 2 51 mm 3 76 mm CableGlider Plus Package 2 3 1 2 89 mm 4 102 mm Tool box for the accessories CableGlider Plus Part Number Description 8674300 110 Volt Plus Cable Puller 8678050 220 Volt Plus Cable Puller for export only International orders must specify plug Warning CableGlider cable pullers are not to be used as a hoist or for lifting supporting or transporting people or loads Complete Pulling Packages for CableGlider Plus Pulling packages offer cost savings and ordering convenience 0 Part Number Description Part Number Description 0 8674392 CableGlider Plus Package 1 8674840 CableGlider Plus Package 4 for export only 110 Volt Puller with accessories above e 220 Volt Puller with accessories above HD Extension frame HD Extension frame 600 ft 183 m of 7 8 22mm double braid rope 600 ft 183 m of 7 8 22mm double braid rope Floor conduit pole mount frame Floor conduit pole mount frame 5 127 mm amp 6 152 mm adapters w retaining fork 5 127 mm amp 6 152 mm adapters w retaining fork Running Line Tensiometer Running Line Tensiometer 86746391 CableGlider Plus Package 2 8674835 CableGlider Plus Package 5 for export only All items in Package 1 plus All items in Package 4 plus Chart recorder for running line tensiometer Chart r
111. se dimensions when ordering the 1 1 4 32mm and the 1 3 8 35mm swivels Use these dimensions when ordering the 1 5 8 41mm 2 51mm the2 1 2 64mm and the 3 76mm swivels A B E F G in mm in in mm in mm in mm in in mm 1 1 4 32 56 14 5 44 138 1 34 34 37 9 59 15 1 3 8 35 56 14 5 25 133 1 31 33 44 11 56 14 1 5 8 41 63 16 6 85 174 1 59 40 56 14 78 20 2 36 60 2 51 75 19 7 83 199 1 81 46 63 16 19 2 89 73 2 1 2 64 1 00 25 10 93 2778 2 84 72 88 22 1 25 32 3 07 93 3 76 1 31 33 12 79 324 3 56 90 1 13 29 1 37 36 4 50 114 111 PERT Break Pin E Bearings Externally Body Internally Threaded Head Threaded Head Replacement Pins for Break A way Directional Drilling Swivels Part Break Load Break Pin Part Break Load Break Pin Number Ibs N Color Code Number Ibs N Color Code 8019405 1 900 8 451 Violet Black 8024505 7 000 31 136 Orange 8019505 2 000 8 896 Slate White 8025505 7 500 33 360 Blue 8019605 2 500 11 120 Violet Green 8027905 8 000 35 584 Yellow 8019705 3 000 13 344 Slate Red 8028405 8 500 37 808 Slate 8076105 3 400 15 123 Blue Yellow 8029205 9 000 40 032 Red 8019805 4 000 17 792 Red Yellow 8029405 10 000 44 480 Green 8019905 4 500 20 016 Slate Yellow 8029605 12 000 53 376 White 8021305 5 000 22 240 Orange Blue 8029705 14 000 62 272 Brown 8022105 5 500 24 464 Brown Green 8029720 18 500 82 288 Black 8024205 6 000 26 688 Blue Brown 8075805 22 000 97 856 Yellow
112. tached to the front of the cable Compressed air propels the carrier and cable through the air tight sealed duct in a matter of seconds And because air flow and tractor drive speed can be adjusted you can install fiber at the rate which best suits any application Compared to other models on the market our Fiber Optic Cable Blower features longer tractor feed grip area for less stress on the cable We incorporate a hydraulic cylinder on the tractor feed to better control down pressure A refined speed and distance counter with LCD read out as well as convenient hydraulic and pneumatic controls come standard with the blower An optional electronic control system is available to monitor the cable and tractor drive speeds This system will shut down the blower if cable slippage an over speed situation or a cable stoppage is detected Compare features and quality to see why our Fiber Optic Cable Blower is better Speed and Distance Readout models come standard with speed and distance display Advanced Electronic Controls Optional system monitors and displays cable and tractor drive speeds Will iol automatically shut off the blower in these conditions e Slippage e Over Speed e Cable Stoppage Cable amp Duct Packs Components provide for the maximum amount of combinations of duct amp cable at the lowest possible price See ordering information for the complete listings Easy to use Convenient hy
113. trength Lbs 5 000 10 000 12 500 17 500 15 500 22 500 22 500 27 500 27 500 32 500 30 000 35 000 36 500 41 500 36 500 41 500 36 500 41 500 45 500 50 500 Weave Single Double Triple Triple Triple Triple Triple Triple Triple Triple Triple Triple 4 Wire 4 Wire 4 Wire 4 Wire 4 Wire 4 Wire Double Double 6 Braided 6 Braided 6 Braided 6 Braided 6 Braided 6 Braided 6 Braided 6 Braided M In Standard Mesh Lengths are Shown Special Lengths Available upon request Special Pulling Grips Model OH Pulling Grips Model OH Pulling Grips designed for the special demands of overhead stringing crews has a basket constructed of triple woven nylon coated Aircraft Strand for maximum abrasive resistance It has special tough plastic boots at eye end to prevent abrasion between the conductor and pulling dollies A steel thimble is manufactured into the eye and is furnished without swivel or steel thimble on request It is easily adaptable to ball bearing swivels Uncoated wire gives approximately 20 more strength Please specify when ordering Copyright 1992 A amp M Sales Inc Cable Approx Part Diameter Breaking Weave E In M In Number Range In Strength Lbs OH30LDW 25 50 10 000 Double 3 30 OH42LTW 3 0 336 M C M 16 000 Triple 4 42 OHASLTW 477 795 M C M 20 500 Triple 4 48 OHSILS5W 795 1 000 M C M 31 500 5 Wire 4 51 Call amp TOLL FREE 1 800 553 6466 or FAX 888 553 6466
114. ugh for the full conduit run Also used as a rotating swivel when pulling wire or rope with the tapered head or mini harness m Fano Rod Dia in mm 3 16 5 1 4 6 5 16 8 7 16 11 9 16 13 ques to USC Thread 12 24 5 16 18 3 8 16 3 8 16 3 4 10 waar Female Female Female 8033470 8033459 Male M Male Female 8033422 8033442 8036800 8036800 8036700 in Metric Thread 5 M8 MI2 M12 M12 Female Female Female 8033429 8033483 Male Female 8033426 8033485 8036806 8036806 8036806 Sonde Adapter Couples a locating sonde or other device with an M10 male thread to the male end fitting of the duct rod Rod Dia in mm 3 16 5 1 4 6 5 16 8 7 16 11 9 16 13 USC Thread 12 24 5 16 18 3 8 16 3 8 16 3 4 10 Sonde Adapter 8036500 8036503 8036503 8036504 Metric Thread M5 8 M12 M12 M12 Sonde Adapter 8036505 8036501 8036501 8036501 Replacement Repair Accessories Threaded End Fittings Use as a replacement to the factory installed end fittings if the end fitting breaks off or if the duct rod breaks close to the end of the rod Installation instructions are included with the end fittings Epoxy is required for installation and is ordered T separately Male End Fitting Rod Dia in Gmm 3 16 5 1 4 6 5 16 8 7 16 11 9 16 13 USC Thread 12 24 5 16 18 3 8 16 3 8 16 3 4 10 8033420 8033440 8036307 8036303 8036005 Female 8036306 8036304 8036006 Metric Thread M5 8 M12 M12 M12 M
115. uit run allowing the cable puller to be positioned farther back and more cable slack to be pulled through Extension frames are availalble in kits that configure to CableGlider Standard Plus and Heavy Duty Cable Pullers Each kit contains CablePuller Adapter Center Joint e Duct End Joint Steel duct 2 Sch 40 GRC not included Extension Frame Kits Part Description 8674940 Kit for CableGlider STD model 8674960 Kit for CableGlider Plus and HD models Replacement Parts Individual Components Part Description 8674928 Puller Adapter fo CableGlider STD model 8674927 Puller Adapter for CableGlider Plus and HD models 8674916 Center Joint for CableGlider STD Plus and HD models 8674901 Duct End Joint for CableGlider STD Plus and HD models Conduit Adapters Additional adapters are available which allow pulling into conduit up to 6 152 mm in size The 5 127 min and 6 152 mm adapters require the use of an optioned retaining fork Also available is a 45 elbow adapter for pulling into tight quarters Adapters for 2 51 mm 3 76 mm 3 1 2 89 mm 4 102 mm conduit are included in a tool box that comes standard with all cable pullers Order additional adapters separately below or order a complete toolbox includes all six items marked with below Straight Adapters Duct Size Part Number in mm 8610642 1 1 4 32 8610623 1 1 2 38 8610643 2 51 8610647 64 8610644 3 76 8610645 3 1 2 89 86106
116. ulling line Number Length Range Load Strength The single wire eye is very flexible and will conform to X 10 FO 5W 10 10 25 500 1500 the tightest of clearances A amp M flexible eye fiber X 25 FO SW 14 254397 500 1500 optic grips are used for the installation of fiber optic X 37 FO SW 24 25 50 750 2200 cables either underground overhead through conduit X 42 FO 5W 24 42 61 750 2200 or through enclosures These pulling grips will pull X 53 FO SW 24 53 74 750 2200 single cables or bundles are easily installed on the X 64 FO SW 24 64 87 750 2200 cable and are reuseable Please use an A amp M HD 00 X 75 FO SW 24 5 1 00 750 2200 ball bearing swivel when installing fiber in order to X 100 FO SW 24 1 00 1 25 750 2200 release tension that would otherwise damage the cable X 125 FO SW 24 1 25 1 50 750 2200 Special Application Fiber Optic Pulling Grips Dual Lift Eye Grip The Dual Lift Eye Grip provides two offset eyes for extra support stability This grip is especially well suited for suspending tempo rary power line cables This grip is made of uncoated galvanized aircraft strand steel for long life and safety Part Working Breaking Number Edn Size Load Strength FO 25 DLE 6 3 1 4 3 8 500 165 1 000 Ibs FO 37 DLE 6 6 1 4 1 2 500 Ibs 1 000 lbs FO 50 DLE 6 6 1 27 5 8 600lbs 1 2501bs FO 62 DLE 6 T 5 8 3 4 600lbs 1 250 Ibs FO 75 DLE 6 T 3 4
117. with extreme bends 7 000 lbs 31 136 N 8021925 2 1 2 64 11 25 286 2 25 57 load capacity 5 8021800 3 76 11 25 286 2 75 70 8049400 3 1 2 89 11 25 286 3 25 83 8021900 4 102 11 25 286 3 75 95 8067500 5 Sch 80 114 11 25 286 4 25 108 5 8058900 5 127 11 25 286 4 75 121 7 8059000 6 152 11 25 286 D 146 i 8079500 8 203 11 25 286 1 15 197 2 000 Ibs 8 896 N load capacity 808 Champion Swivels F PES Designed specifically for underground cable pulling applications Can handle all types of utility cables Precision machined from high strength steel CAUTION To be used for cable stringing or pulling only NOTE Swivels are not designed to run around bullwheels Part Working Load A B Number Ibs N in mm in mm in mm in mm in mm in mm 8017000 600 2 669 5 8 16 28 7 3 56 90 79 20 Ms 6 37 9 HD 00 1 500 6 672 7 8 22 a 13 5 06 127 Nf 10 8016000 1 800 8 006 7 8 22 38 10 4 51 115 1 06 24 31 8 53 13 W 1 3 000 13 344 1 5 16 33 625 16 6 69 168 44 11 8080912 4 000 17 792 1 1 4 32 56 14 5 44 138 1 34 34 37 9 59 15 HD 0 5 400 24 019 1 1 8 20 5 13 5 06 127 44 11 W 2 5 400 24 019 1 5 8 41 875 22 6 69 168 5 13 8080913 6 500 28 912 1 3 8 33 56 14 3 29 133 1 31 33 44 11 56 14 8080916 8 500 37 808 1 5 8 41 63 16 6 51 165 1 59 40 56 14 78 20 HD 1 9 000 40 032 1 3 8 35 9 13 6 38 160 2 13 8080920 10 000 44 480 2 51 75 19 6 99 178 1 78 45 62 16 d2 18 HD 2 12 000 53
118. x 171 chagrin falls ohio 44022 440 708 0180 Duct Rodder Accessories ee i Mini Harness I Roller Guide Flexible Leader ee Threaded End Fig Male INCLUDED ON ALL ROD Shackle Fig Tappered Head O Ring Threaded End Fig Male Swivel Coupling Mini CoBRA FEMALE FEMALE E a ea Threaded End Fig Female CoBRA amp PvrHRON m _ _ l Swivel Coupling MALE FEMALE Accessory Kit Popular accessories available in a convenient bag that attaches to the Mini Cobra cage Kit Includes Roller Guide Splice Kit Epoxy Swivel Coupling Tapered head and Threaded End Fittings RodDia in mm 3 16 5 1 4 6 5 16 8 7 16 11 9 16 13 USC Thread 112 24 5 16 18 3 8 16 3 8 16 3 4 10 Accessory Kit 8033498 8033499 8033497 8033494 8033488 Metric Thread M5 Ms M12 M12 M12 Accessory Kit 8033492 8033493 8033496 8033495 8033489 Kits for 3 16 5 mrn and 1 4 6 rrim rod also include Flexible Leader ard O Rings UP a 8033490 Bag Shackle Fitting Fits onto tapered head to provide a larger pulling loop for attaching the rope or pull line RodDia in mm 3 16 5 1 4 6 5 16 8 7 16 11 9 16 13 USC Thread 12 24 5 16 18 3 8 16 3 8 16 3 4 10 ShackleFittinq 8031101 8031101 8031100 Metric Thread M5 8 12 12 M12 Shackle Fitting 8031101 8031101 8031101 Flexible Leader Helps guide the duct rod arou
119. x 9 16 x 3 16 38 x 14 x 5mm hot rolled steel channel hot dip galva nized T slots for attaching hooks are spaced at 1 1 2 38 mm intervals The 8 14 and 18 hole racks have 19 32 X 3 4 15x 19 mm mounting slots at each end that interlock so two or more racks may be combined into one unit Longer racks are mounted through the T slots Use 1 2 or MI 2 mounting hardware see Mounting Hardware Part Support Length Bolt Hole Spacing Number Holes in mm in mm 8380000 8 15 381 131 2 343 8380100 14 24 610 221 2 572 8380200 18 30 762 281 2 724 8380300 37 55 1 4 1 403 8380400 43 64 1 4 1 631 6383500 47 70 1 4 1 784 8380500 54 81 2 057 Cable Rack Hooks Designed to fit snugly into the rack slots Turned up ends prevent cable or rack insulators from slipping off Manufactured from 3 16 5 mm steel and hot dip galvanized with smooth surfaces to prevent cable damage Ext Part mm 8380600 4 102 8380700 71 2 190 8380800 10 254 8380900 l4 356 8381000 18 457 Cable Rack Insulator Made of glazed porcelain the insulators rest on the cable rack hooks providing additional protection for the cable Part Groove Radius Groove A Width Groove B Width Number in mm in mm in mm 8381200 11 2 38 2 3 4 70 3 76 Cable Rack Support To extend the racks away from the wall and avoid obstructions or water seepage Each rack requires two supports Hot dip galvanized Use 1 2 or M1
120. y rod designed for heavy duty applications It gets its extra strength from a unique construction process that ensures greater rigidity and strength enabling it to endure the additional force required for long duct runs with multiple bends and sweeps A braided wrap of reinforcing fibers increases its rigidity and helps bond the core with the outer plastic coating The coating is made from a polymer blend for greater toughness and superior abrasion resistance to ensure extra long life Includes one male and one female end fitting and a tapered head PYTHON Our Python rod is best suited for less demanding applications It has strength properties similar to our Cobra rod but is more flexible Also like the Cobra it has a heavy duty outer plastc coating to resist abrasions and reduce wear Includes one male and one female end fitting and a tapered head MINI COBRA 9 Our Mini Cobra rod includes our 3 16 5 mm and 1 4 mm diameter rods used primarily for smaller duct sizes and shorter runs The rod has the same flexibility and strength features of our Python rod and comes wound in 16 406 mm and 24 610 mm cages in 50 25 m to 600 200 m lengths Includes two male end fitings and two tapered heads REPLACEMENT Replacement rod is available for all A amp M Duct Rodders Have your existing duct rodder part number ready to ensure an accurate match Replace ment rod 3 16 5 mm to 1 4 6 mm comes with end fittings and tap
121. zes are base on standard radius bends and should not be considered minimums Fiberglass Rod Units amp Replacement Rod 3 16 Mini Cobra Rod 12 24 End Fitting 16 Cage Length Replacement Length Replacement Part No 8072405 8072410 8072415 PartNo 8072510 8072515 8072520 8072525 8072530 8072535 Part No 8083720 8083725 8083730 8083735 8083740 8083745 8083750 8083755 ft 50 100 150 1 4 Mini Cobra Rod Length ft 100 150 200 250 300 5 16 Cobra Rod Length ft 200 250 300 400 500 Replacement Rod No 8073605 8073610 8073615 Replacement RodNo 8073710 8073715 8073720 8073725 8073730 8073735 RodNo 8079120 8079125 8079130 8079135 8079140 8079145 8079150 8079155 Part No 8072420 8072425 8072430 5 16 18 End Fitting Part No 8072540 8072545 8072550 8072555 8072560 3 8 16 End Fitting Part No 8083760 8083765 8083770 8083775 8083780 8083790 8083710 ft 200 250 300 Length ft 400 450 500 550 600 Length ft 600 650 700 750 800 900 1000 Replacement Replacement Copyright 1992 A amp M Sales Inc Call A amp M TOLL FREE 1 800 553 6466 or FAX 888 553 6466 RodNo 8073620 8073625 8073630 24 Cage RodNo 8073740 8073745 8073750 8073755 8073760 30 Cage RodNo 8079160 8079165 8079170 8079175 8079180 8079190 8079110 ES a