Home
SmartModel Library Installation Guide
Contents
1. Chapter 4 Authorizing and Configuring the Library SmartModel Library Installation Guide Create the License Files Use the following procedure to create the license files 1 Create a file named smartlicense dat in the LMC_HOME data directory Choose the format below that matches the information in the Authorization Certificate you received Format A old license daemon SERVER hostname hostid 5300 DAEMON la_dmon full _path_to_la_dmon FEATURE feature_name la_dmon 1 000 expire_date token_count auth_code options Format B new Synopsys Common Licensing daemon SERVER hostname hostid 5305 VENDOR snpslmd full_path_to_snpsimd INCREMENT feature_name snpslmd 1 000 expire_date token_count auth_code options For a detailed description of the FLEXIm license file refer to the FLEXIm documentation at LMC_HOME doc flexlm TOC htm 2 In the FEATURE or INCREMENT line enter the feature_name expire date token_count and auth_code from your Authorization Certificate 3 In the SERVER line enter the hostname and hostid The hostid is listed in your Authorization Certificate but you need to provide the hostname Also note that some Authorization Certificates list a portid of 5300 or 5305 as shown in the format examples above but you can substitute any unused portid for your license server 4 If you are using Format B in the VENDOR line enter the full path to the license daemon as follows scl_root platform bin snp
2. How Licensing Works Following are details on how SmartModel licenses work e Per Model Licenses License tokens are consumed on a per model basis not a per instance basis Multiple instances of a specific model in a single simulation consume only one license token Each simulation session requires license tokens for the models in that simulation If you run multiple simulations concurrently each simulation consumes one or more license tokens e License Requires Live Server Connection The licensing software maintains a connection with the license server If the connection is broken the license is revoked April 2001 Synopsys Inc 19 Chapter 3 Network Licensing for SmartModels SmartModel Library Installation Guide 20 Licenses Are Release Independent SmartModel license feature lines do not use the feature version field This means that new licenses are not required to license new releases of the SmartModel software Merged Licenses Supported on Same Server SmartModel licenses may be merged with other FLEXIm features However all feature lines must have been generated for the same license server Expiration at Midnight Licenses expire at midnight of the expiration date given in the feature line License Usage Algorithm When a model is loaded by the simulator it needs to obtain a valid license token before it can run Either a DesignWare license feature or one of the legacy SIMMODEL based license features will authoriz
3. click on OK By default new variables that you enter become User environment variables If you have administrator privileges you will also be allowed to create System environment variables Note that any User variables that you create will override System variables set up by the system administrator at your site If the NT machine where you installed the SmartModel Library is to be used by multiple users it is probably best to set basic environment variables such as LMC_HOME as System variables To do this you need administrator privileges First highlight an existing entry in the System or User Variables portion of the System Properties window Then enter the variable name and value and click Set Running Console Applications on NT Platforms Many SmartModel Library user procedures assume that you have access to a UNIX shell such as the C shell For example instructions and examples for using SmartModel Library command line tools assume that you have access to a C shell If you are running on an NT platform use the Console Application to run these tools To access the Windows NT Console Application select Start gt Programs gt Command Prompt This environment looks like DOS but it works fine for running installed programs from the command line just as you would in UNIX References to environment variables on the NT command line must be delimited by the percent sign This differs from the way environment
4. information about Verilog XL third party tool requirements refer to the Cadence documentation Installation Considerations Before you install any models please note the following e The SmartModel products in this release should be installed by a system administrator e When installing the same release of a SmartModel product for multiple UNIX platforms for example Solaris and HP UX install the products in the same top level directory e You can install the entire library but you will decrease the size of your installed image if you install only those models used in designs at your location You can easily install additional models at a later date gt Note You cannot perform cross platform installations between UNIX and NT in either direction 10 Synopsys Inc April 2001 SmartModel Library Installation Guide Chapter 1 Installation Preparation Setting Environment Variables on NT Platforms Many SmartModel Library installation and configuration steps require that you set environment variables Most of the examples in this manual show how to set an environment variable in UNIX using a C shell For NT you set environment variables using the System Properties window To access the System Properties window select Start gt Settings gt Control Panel and double click the System icon From the System Properties window select the Environment tab enter the variable name and value and click Set To dismiss the window
5. l log file path e path_to_lmgrd To remove the service invoke installs exe using the remove switch r gt Note Be sure to start the appropriate Imgrd binary for your license server machine type The binaries reside at LMC_HOME lib platform_name lib lmgrd where platform_name is either hp700 ibmrs pent or sun4Solaris For more information about installing and using the FLEXIm licensing software refer to the FLEXIm documentation at XLMC_HOME doc flexlIm TOC htm You can also find more information about FLEXIm on the GLOBEtrotter Web page at http www globetrotter com Step 2 Configure each User s Environment For each account that requires access to a SmartModel product enter the following commands at the UNIX prompt or if you want them to persist add them to your startup file For information on how to set environment variables and how to use the console application on NT platforms refer to Setting Environment Variables on NT Platforms on page 11 and Running Console Applications on NT Platforms on page 11 1 Set your LMC_HOME environment variable to the install directory as shown in the following example setenv LMC HOME install directory 2 Set your LMC_CONFIG environment variable if you want to use model versions that are different from the versions specified in the default configuration file The LMC_CONFIG variable points to the locations of one or more custom configuration files each of whi
6. AGP Test Suite Installation 0 ccc ccc ccc cece cece eee eens 29 DARI wine Chey hk eee dai Ei 29 RR 31 4 Synopsys Inc April 2001 SmartModel Library Installation Guide Preface Preface About This Manual This document provides information about installing and configuring the SmartModel Library Related Documents For general information about SmartModel Library documentation or to navigate to a different online document refer to the Guide to SmartModel Documentation For the latest information on supported platforms and simulators refer to SmartModel Library Supported Simulators and Platforms For detailed information about specific models in the SmartModel Library use the Browser tool LMC_HOME bin sl_browser to access the online model datasheets Manual Overview This manual contains the following chapters and appendixes Preface Describes the manual and lists the typographical conventions and symbols used in it tells how to get technical assistance Chapter 1 Requirements considerations and environment Installation Preparation variables for installation Chapter 2 How to install the SmartModel Library models Installation Procedure Chapter 3 Describes elements unique to the Synopsys Network Licensing for implementation of FLEXIm SmartModels April 2001 Synopsys Inc 5 Preface SmartModel Library Installation Guide Chapter 4 How to authorize SmartModel Library models and Authorizing and Confi
7. Install the Acrobat Reader Software i Step 2 Load the SmartModel CD ROM and Mount the Drive Step 3 QuickSim II Users Only Set LM_LICENSE_FILE and MGC_HOME Step 4 Use the Admin Tool to Install the Models and Library Tools Library Tool and Documentation Installation 0000 Accessing Online Documentation ascii ir LMC HOME Directory Structure siii Edi ORARIA LMC_HOME bin Directory svariati LMC_HOME doc Directory either LMC OME Directory Lascia init lata Mehosevewe es LMC_HOMF include Directory csi SL HOME mod dels DIO asso dno kode Ghee baia LMC HOME data Diy siste SLM HOME special Directoy corri iaia April 2001 Synopsys Inc Contents SmartModel Library Installation Guide Chapter 3 Network Licensing for SmartModels ccc cece cece cc ccccccccscees 19 WOU dread CA ARR a ee Kea RRS AA LEAR SER ONES SS 19 How Licensing WOrkS seria 19 Chapter 4 Authorizing and Configuring the Library cc cece eee cece ences 21 Idle 1 RARE eae ae eee oe Ae eee T E EE 21 Step 1 Authorize the SmartModel Products cirie keene aceaw es 21 Create he License Files asia Tdi 2a Start the License Server Daemons UNIX Platforms 23 Start the License Server Daemons NT Platforms iii 23 Step 2 Configure each User s Environment sussesesessresreerse 24 Chapter 5 Debugging the Installation i iii 27 eC ee hie sore deere able ZI Appendix A PCI
8. SYNOPSYS SmartModel Library Installation Guide SmartModel Library Installation Guide Copyright 2001 Synopsys Inc All rights reserved Printed in USA Information in this document is subject to change without notice SmartModel ModelAccess ModelTools SourceModel Library LM 1200 and Synopsys Eaglei are registered trademarks MemPro MemSpec MemScope FlexModel LM family LM 1400 Logic Model ModelSource and SourceModel are trademarks of Synopsys Inc All company and product names are trademarks or registered trademarks of their respective owners Synopsys Inc April 2001 SmartModel Library Installation Guide Contents Contents aot ne ee ree re eer ee re re eee AAA A Abomt This Mammal ieri eeeh atta Fee OU iii idoli eee sede tinea Mannal OVOCIE hie ceiens woeed dos onde ohh be ei ee let Typographical and Symbol Conventions 92 46 05 0e s aes eins saaesiaseren CE saliti iodato cio The Synopsys Websil iii TITRES LETI SE Synopsys Common Licensing SCL Document Set CEE arrivo AA Chapter 1 Installation Preparation cascine lies RR ATTO DES asia iaia paia Third Party Tool Requirements ihih reiherra eri Installation Considerations iii irradia Setting Environment Variables on NT Platforms 22 444 054 iii Running Console Applications on NT Platforms L 00005 Chapter 2 Installation Procedure ss 445 6K bd di ERRE RE ai Per hh eho ee EEE ORO ae E OI OTTO Step 1
9. ation refer to Debugging the Installation on page 27 26 Synopsys Inc April 2001 SmartModel Library Installation Guide Chapter 5 Debugging the Installation 9 Debugging the Installation Using swiftcheck The swiftcheck utility identifies common problems you may encounter when using SmartModels in the SWIFT environment The swiftcheck tool e Checks that required environment variables are properly set e Verifies that the SmartModels are properly installed e Loads a user specified model and exercises basic functionality To get a usage message for swiftcheck enter the following command at the prompt LMC_HOME bin swiftcheck u For a detailed description of the checks performed by swiftcheck enter the following command LMC_HOME bin swiftcheck h For more information about the swiftcheck utility refer to the SmartModel Library User s Manual April 2001 Synopsys Inc 27 Chapter 5 Debugging the Installation SmartModel Library Installation Guide 28 Synopsys Inc April 2001 SmartModel Library Installation Guide Appendix A PCI AGP Test Suite Installation A PCI AGP Test Suite Installation Introduction The PCI Test Suite for both SourceModel and FlexModel PCI users and the AGP SourceModel Test Suite install just like regular SmartModels using the Admin tool as detailed in this installation guide The model name for the PCI test suite product is pci_ts and the model name for the test sui
10. ch must have an extension of Imc Specify multiple custom configuration files in the order that you want them searched and separate the names with colons as shown in the following example setenv LMC CONFIG filel lmc file2 lmc file3 lmc For NT you must separate multiple entries for the LMC_CONFIG environment variable using a semicolon separated list not a colon separated list as in UNIX 24 Synopsys Inc April 2001 SmartModel Library Installation Guide Chapter 4 Authorizing and Configuring the Library 3 Add the license file to the search path by setting the LM_LICENSE_FILE environment variable or the SmartModel specific LMC_LIC_FILE environment variable gt Note Customers on NT using a simulator running a version of FLEXIm prior to v5 1 cannot use the LM_LICENSE_FILE variable to point to more than one license file To work around this limitation you can use the LM_LICENSE_FILE variable to point to your simulator license file and the LMC_LIC_FILE variable to specify one or more SmartModel license files a If LM_LICENSE_FILE is not already set enter this command setenv LM LICENSE FILE LMC_HOME data smartlicense dat b If LM_LICENSE_FILE is already set enter this command Q setenv IM LICENSE FILE LM_LICENSE_FILE LMC_HOME data smartlicense dat For NT you must separate multiple entries for the LM_LICENSE_FILE or LMC_LIC_FILE environment variables using a semicolon separated list not a colon s
11. d disk space 10 32 SmartModel Library Installation Guide T Tools Admin 15 Admin invocation commands 15 Imgrd 23 mount 14 sl_browser 16 swiftcheck 27 V Variables environment LD_LIBRARY_PATH 25 LM_LICENSE_ FILE 14 25 LMC_CONFIG 24 LMC_HOME 16 22 24 LMC_PATH 26 ViewSim required disk space 10 Synopsys Inc April 2001
12. e If you installed the SmartLicense Network Authorization software at the default location licensefile_path is LMC_HOME data smartlicense dat 3 To start the server daemons automatically whenever the license server node reboots edit the applicable rc local file to add these lines if f lmgro path then Imgrd_path c licensefile path 1 usr tmp smartlicense log amp echo Imgrd c gt dev console fi If you are unsure about which rc local file to edit check with your system administrator The actual file name varies from one platform to another Use the same values for lmgrd_path and licensefile_path as described in Step 2 Start the License Server Daemons NT Platforms Use the following procedure to start the license server daemons on an NT platform 1 On the license server node invoke the license daemon as follows lmgrd_path lmgrd app c licensefile path l license _log path April 2001 Synopsys Inc 23 Chapter 4 Authorizing and Configuring the Library SmartModel Library Installation Guide 2 To start the server daemons automatically whenever the license server node reboots run the installs exe program from GLOBEtrotter to install Imgrd as a service You can find the installs exe program in the LMC_HOME bin directory after you install the SmartModel Library You must be logged on as an administrator to run the installs exe program Use the following syntax installs c licensefile path
13. e a model These two types of license features are not additive Synopsys Inc April 2001 SmartModel Library Installation Guide Chapter 4 Authorizing and Configuring the Library 4 Authorizing and Configuring the Library Introduction To complete the setup for the SmartModel Library following these steps e Step 1 Authorize the SmartModel Products e Step 2 Configure each User s Environment Step 1 Authorize the SmartModel Products Before authorizing the library you must have one or more authorization codes You may have received these with your order via the Web or directly from your sales representative If you do not have an authorization code contact your local Synopsys sales office to get one Note that authorization codes are keyed to the license server you specified on your order If you have changed servers you need to obtain new codes The following procedure describes how to configure SmartModel products to use the SmartLicense Network Authorization software lt gt Note If you are using an NT machine as your license server you must install the network driver and an Ethernet card for network access The network driver can be installed in several ways 1 as an SNMP service 2 NETBEUI Transport Protocol or 3 NW Link IPX SPX Transport Protocol For more information on installing the network driver refer to the FLEXIm documentation at LMC_HOME doc flexIm TOC htm April 2001 Synopsys Inc 21
14. eparated list as in UNIX For example in this step if the LM_LICENSE_FILE variable is already set and you want to add a license file for SmartModel Library authorization set the value of the environment variable as follows SLM LICENSE FILE LMC_HOME data smartlicense dat c To use the LMC_LIC_FILE variable enter this command Q setenv IMC LIC FILE LMC_HOME data smartlicense dat 4 Set the executable search path to include the path name to the Synopsys tools directory as shown in the following example set path existing_path_entries LMC_HOME bin 5 For Solaris only set the LD_LIBRARY_PATH as shown in the following example o setenv LD_LIBRARY_PATH IMC_HOME lib sun4SunOS lib If LD_LIBRARY_PATH is already set enter o setenv LD_LIBRARY_PATH LMC_HOME lib sun4SunOS 1ib LD_LIBRARY_PATH April 2001 Synopsys Inc 25 Chapter 4 Authorizing and Configuring the Library SmartModel Library Installation Guide 6 If you have custom timing versions you want to use you may need to set the LMC_PATH environment variable For more information on creating and using a custom timing version refer to the SmartModel Library User s Manual TS Note For NT multiple entries in the LMC_PATH variable must be separated by semicolons not colons as in UNIX 7 If after setting up a library the installed products do not operate correctly you can debug the installation using the swiftcheck tool For more inform
15. ex Index E Environment variables LD_LIBRARY_PATH 25 LM_LICENSE_ FILE 14 25 LMC_CONFIG 24 LMC_HOME 16 22 24 LMC_PATH 26 Environment user configuration 24 F Files license 22 25 FLEXIm 24 I Installation Admin and Browser tools 15 considerations 10 library versioed tools 15 models Admin tool 15 SmartModel library 9 SmartModel Library documentation 15 steps for 13 Intel NT command line 11 console application 11 licensing 23 setting environment variables 13 L Libraries authorizing 21 model using Admin tool 15 setting up 21 SmartModel setting up 21 Library SmartModel installation 9 License files 22 25 server daemons 23 April 2001 Synopsys Inc 31 Index Licensing DesignWare license feature 20 network 19 SIMMODEL licesnes features 20 SimModels 19 LM_LICENSE_FILE 14 25 Imgrd command 23 M MGC_HOME 14 Models installation Admin tool 15 mount command 14 N NT Intel command line 1 console application 11 licensing 23 setting environment variables 13 Q QuickSim II required disk space 10 S Servers license daemons 23 SIMMODEL license features 20 SimModels licensing 19 Simulators QuickSim II required disk space 10 ViewSim required disk space 10 sl_browser command 16 SmartModel Browser invoking 16 SmartModels authorizing 21 installation considerations 10 library installation 9 library setting up 21 swiftcheck command 27 Symbols require
16. f a model in the same LMC_HOME models directory it is important to use the Browser tool sl_browser to access the correct version of the model datasheet LMC_HOME data Directory This directory contains library configuration files platform Imc files needed by the SmartModel version control software A configuration or Imc file is a list of SmartModel Library models each with a specific version defined For more information on configuration files refer to the SmartModel Library Administrator s Manual LMC_HOME special Directory This directory contains simulator specific data such as schematic capture symbols supplied by Synopsys 18 Synopsys Inc April 2001 SmartModel Library Installation Guide Chapter 3 Network Licensing for SmartModels 3 Network Licensing for SmartModels Introduction Synopsys simulation models use GLOBEtrotter Software FLEXIm floating licenses to control their usage This section describes the elements that are unique to the Synopsys implementation of FLEXIm All models are first loaded by the simulator Each model then acquires its license as the simulator initializes it The model keeps its license token until the simulator exits Models do not release license tokens when the simulator is paused After installation the FLEXIm documentation is available at LMC_HOME doc flexlm TOC htm For more information about FLEXI1m refer to the GLOBEtrotter Web site http www globetrotter com
17. g directory structures under LMC_HOME doc e smartmodel manuals contains all of the PDF manuals as well as the install guide and release notes e smartmodel readme contains the ASCII readme file e admin help contains PDF based help files for the Admin and Browser tools Although it is possible to view PDF documentation directly using third party tools we recommend that you use the Admin and Browser tools to ensure that you always get the correct version of the documentation April 2001 Synopsys Inc 17 Chapter 2 Installation Procedure SmartModel Library Installation Guide LMC_HOME lib Directory This directory is for binaries scripts and data not directly associated with a specific model There is a separate subdirectory underneath LMC_HOME lib for each supported platform where platform is either hp700 ibmrs pent sun4Solaris or x86_linux Do not alter the contents of this directory LMC_HOME include Directory The include directory is for simulator interface source files provided by Synopsys These are generally header files for Verilog PLI simulations but may be C source or other source that needs to be compiled and linked with a simulator Do not alter the contents of this directory LMC_HOME models Directory This directory contains all of the models you have installed Each model comes with a datasheet that is located in LMC_HOME models model_name Because it is possible to have more than one version o
18. guring configure environments for their use the Library Chapter 5 How to debug an installation using the swiftcheck tool Debugging the Installation Appendix A Information about installing the PCI and AGP test suites PCI AGP Test Suite Installation Typographical and Symbol Conventions Default UNIX prompt Represented by a percent sign 3 User input text entered by the user Shown in bold type as in the following command line example ed LMC_HOME hd1 System generated text prompts messages files reports Shown as in the following system message No Mismatches 66 Vectors processed 66 Possible Variables for which you supply a specific value Shown in italic type as in the following command line example setenv LMC_HOME prod_dir In this example you substitute a specific name for prod_dir when you enter the command Command syntax Choice among alternatives is shown with a vertical bar as in the following syntax example effort_level low medium high In this example you must choose one of the three possibilities low medium or high Synopsys Inc April 2001 SmartModel Library Installation Guide Preface Optional parameters are enclosed in square brackets as in the following syntax example pinl pin2 pinN In this example you must enter at least one pin name pin but others are optional pin2 pinN Getting Help If you have a question while using Synopsys
19. ibrary Installation Guide Chapter 2 Installation Procedure o For NT machines set MGC_HOME to your_mgc_directory for information on the procedure for setting environment variables on NT machines refer to Setting Environment Variables on NT Platforms on page 11 This causes the Admin tool to automatically generate SmartModel menu entries in Design Architect Note that you must have an active MGC license for the menus to build successfully If you do not set MGC_HOME before installation you must install the SmartModel menus in Design Architect yourself Step 4 Use the Admin Tool to Install the Models and Library Tools Use the Admin tool to install the models Refer to Table 3 to find the appropriate command for invoking the Admin tool on your platform If you are mounting from an FTP image substitute the FTP image location for cdrom The Admin tool steps you through setting your LMC_HOME environment variable and selecting your installation platform Answer the questions as prompted Table 3 Admin Tool Invocation Commands OS Command HP UX cdrom SL_ADMIN CSH Solaris cdrom cdrom0 sl_admin csh AIX cdrom sl_admin csh NT If the Admin tool sl_admin does not start up automatically when you insert the SmartModel CD ROM in the drive navigate to the CD ROM drive open the pent folder and double click on the sl_admin exe file Linux cdrom sl_admin csh Library Tool and Documentation Installati
20. l Library Installation Guide Step 2 Load the SmartModel CD ROM and Mount the Drive This step requires root privileges Table 2 lists some generic mount commands that may or may not be correct for your system depending on its configuration If necessary check with your system administrator before using these commands Table 2 Generic Mount Commands OS Command HP UX etc mount r F cdfs device_name cdrom Solaris Automatically mounted at cdrom cdrom0 if you are running vold daemon if not consult your system administrator AIX etc mount v cdrfs o ro NT Insert the CD in your CD ROM drive Linux bin mount t iso9660 dev cdrom mnt cdrom Step 3 QuickSim Il Users Only Set LM_ LICENSE FILE and MGC HOME QuickSim II users need to set these environment variables in order to have a proper SmartModel Library installation 1 Set the LM_LICENSE_FILE environment variable as shown in the following examples o For UNIX machines setenv LM LICENSE FILE path_to_mgc_authorization_file o For NT machines set LM_LICENSE_FILE to path_to_mgc_authorization_file for information on the procedure for setting environment variables on NT machines refer to Setting Environment Variables on NT Platforms on page 11 2 Set the MGC_HOME environment variable as shown in the following examples o For UNIX machines setenv MGC_HOME your_mgc_directory 14 Synopsys Inc April 2001 SmartModel L
21. mon licensing SCL software is delivered on a CD that is separate from the tools that use this software to authorize their use The SCL documentation set includes the following publications which are located in root docs scl on the SCL CD and also available on the Synopsys FTP server ftp ftp synopsys com e Licensing QuickStart 142K PDF file This booklet provides instructions for obtaining an electronic copy of your license key file and for installing and configuring SCL on UNIX and Windows NT e Licensing Installation and Administration Guide 2 08M PDF file This guide provides information about installation and configuration key concepts examples of license key files migration to SCL maintenance and troubleshooting You can find general SCL information on the Web at http www synopsys com keys Comments To report errors or make suggestions please send e mail to doc synopsys com To report an error that occurs on a specific page select the entire page including headers and footers and copy to the buffer Then paste the buffer to the body of your e mail message This will provide us with information to identify the source of the problem 8 Synopsys Inc April 2001 SmartModel Library Installation Guide Chapter 1 Installation Preparation 1 Installation Preparation Introduction Before installing the library please note the following e Disk Space Requirements e Third Party Tool Requirements e Ins
22. n window 3 Click on the datasheet icon it looks like an AND gate to display the datasheet for that version of the selected model LMC_HOME Directory Structure LMC_HOME is the place for all SmartModel Library model and simulation products Before installation you set your LMC_HOME environment variable to point to this location After installation you can locate the installed software using the same environment variable The LMC_HOME directory structure is organized as shown in Figure 1 16 Synopsys Inc April 2001 SmartModel Library Installation Guide Chapter 2 Installation Procedure s _ browser sl_ admin smartccn LMC HOME swiftcheck doc ib include models data special platform lib la_dmon_platform mc files Figure 1 LMC_HOME Directory Structure LMC_HOME bin Directory This directory contains all of the user tools This includes the Admin sl_admin and Browser sl_browser GUI tools and the other command line tools such as compile_timing smartccn and swiftcheck LMC_HOME doc Directory This directory contains subdirectories for product documentation which is provided primarily in Portable Document Format PDF The number of subdirectories underneath LMC_HOME doc depends on the number of Synopsys products you have installed For example SmartModel Library customers always have the followin
23. on When you install one or more models using the Admin tool at the root level of the CD ROM the Admin and Browser library tools are installed into your LMC_HOME bin directory by default In addition all of the SmartModel Library documentation in your LMC_HOME doc smartmodel manuals directory is updated with the latest available versions Other library tools like mi_trans are also updated automatically when you install new models into your existing LMC_HOME tree For information on using the library tools refer to the following manuals April 2001 Synopsys Inc 15 Chapter 2 Installation Procedure SmartModel Library Installation Guide e Browser Tool SmartModel Library User s Manual e Admin Tool SmartModel Library Administrator s Manual Accessing Online Documentation You can access the SmartModel Library online documentation from the Admin or Browser tools using the Doc pull down menus To access the versioned model datasheets be sure to use the Browser tool so that you do not inadvertently open the wrong file The Browser handles versioning for you based on the selected model version Before invoking the Browser tool ensure that your LMC_HOME environment variable is set to your install directory 1 Invoke the Browser tool to open the Browser window as shown in the following example LMC_HOME bin sl_browser 2 Select the installed model that you are interested in by clicking on it in the Browser model selectio
24. products use the following resources 1 Start with the available product documentation installed on your network or located at the root level of your Synopsys CD ROM Every documentation set contains overview information in the intro pdf file Additional Synopsys documentation is available at this URL http www synopsys com products Im doc Datasheets for models are available using the Model Directory http www synopsys com products Im modelDir html 2 Visit the online Support Center at this URL http www synopsys com support lm support html This site gives you access to the following resources o SOLV IT the Synopsys automated problem resolution system o product specific FAQs frequently asked questions o lists of supported simulators and platforms o the ability to open a support help call o the ability to submit a delivery request for some product lines 3 If you still have questions you can call the Support Center North American customers Call the Synopsys Eaglei and Logic Modeling Products Support Center hotline at 1 800 445 1888 or 1 503 748 6920 from 6 30 AM to 5 PM Pacific Time Monday through Friday International customers Call your local sales office April 2001 Synopsys Inc 7 Preface SmartModel Library Installation Guide The Synopsys Website General information about Synopsys and its products is available at this URL http www synopsys com Synopsys Common Licensing SCL Document Set Synopsys com
25. slmd If you are using Format A in the DAEMON line enter the full path to the license daemon as follows full path to _LMC_HOME lib platform lib la_dmon where platform is either decalpha hp700 ibmrs pent sun4Solaris or sun4SunOS 22 Synopsys Inc April 2001 SmartModel Library Installation Guide Chapter 4 Authorizing and Configuring the Library Va Caution Include all of your Synopsys snpslmd based product and feature authorizations in the same smartlicense dat file However do not include la dmon based authorizations in the same file with snpslmd based authorizations If you have authorizations that use la_dmon keep them in a separate license file that uses a different license server Imgrd process than the one you use for snpslmd based authorizations After you have created the license files start the license server daemons using the procedure appropriate for your platform Start the License Server Daemons UNIX Platforms Use the following procedure to start the license server daemons on a UNIX platform 1 Check for the existence of the file usr tmp smartlicense log If this file exists delete or rename it 2 On the license server node invoke the license daemon as shown in the following example o Imgrd_path 1mgrd c licensefile path l license log_path where mgrd_path is the absolute path to the Imgrd binary for your server platform and licensefile_path is the absolute path and name of the license fil
26. tallation Considerations e Setting Environment Variables on NT Platforms e Running Console Applications on NT Platforms For information about known problems and workarounds refer to the SmartModel Library Release Notes For the latest information on supported platforms and simulators refer to SmartModel Library Supported Simulators and Platforms Disk Space Requirements Installing the latest version of all models in this SmartModel product release requires up to 900 MB of disk space The actual disk space varies depending on the number of models installed the number of versions of each model and the simulator options specified If you install on more than one platform the second and all subsequent platforms require roughly 80 percent of the disk space needed to install on the first platform April 2001 Synopsys Inc 9 Chapter 1 Installation Preparation SmartModel Library Installation Guide Table 1 shows the additional disk space requirements for symbols used by some simulators Table 1 Disk Space for Simulator Dependent Symbols Simulator Disk Space For Symbols Mentor Graphics QuickSim II 125 MB Viewlogic ViewSim 75 MB Third Party Tool Requirements Customers on NT who want to use SmartModels with the Verilog XL simulator need to have an appropriate compiler installed in order to create the necessary libpli dll In our own testing we used Microsoft Visual C as recommended by Cadence For the latest
27. te product is agp_ts If you want to install either tool just highlight the appropriate model name in the Admin tool main window before you click on the install button Va Caution If you are a SourceModel customer who has not used SmartModel products before be sure to set your LMG_HDL_HOME environment variable to point to the location of your SourceModel installation and set LMC_HOME to point to a new location where you want to install the SmartModel Library software including the pci_ts PCI Test Suite or agp_ts AGP Test Suite products If you leave your LMC_HOME variable pointing to your SourceModel tree and then install the SmartModel software in that same location the Test Suite installation will fail April 2001 Synopsys Inc 29 Appendix A PCI AGP Test Suite Installation SmartModel Library Installation Guide 30 Synopsys Inc April 2001 SmartModel Library Installation Guide A Acrobat Reader Intel NT 13 Admin and Browser tools installation 15 Admin tool 15 invocation commands 15 Authorization SmartModels 21 B Browser SmartModel invoking 16 C CD ROM loading 14 Codes authorization 21 Commands invocation 15 Imgrd 23 mount 14 sl_browser 16 swiftcheck 27 D Daemons license server 23 Debugging with swiftcheck 27 DesignWare license feature 20 Disk space required QuickSim II 10 ViewSim 10 Documentation installation 15 Documentation online accessing 16 Drive mounting 14 Ind
28. variables are typed on the UNIX command line where the variable is simply introduced with the dollar sign For example LMC_HOME bin mytool works on UNIX platforms but must be typed as LMC_HOME bin mytool on NT April 2001 Synopsys Inc 11 Chapter 1 Installation Preparation SmartModel Library Installation Guide 12 Synopsys Inc April 2001 SmartModel Library Installation Guide Chapter 2 Installation Procedure 2 Installation Procedure Introduction This procedure describes how to install SmartModel products Before installation make sure that you have e Approximately 900 MB of disk space e Read write and execute rights to the directory where you want to install the product e Access to aC shell during installation not required for NT Step 1 Install the Acrobat Reader Software Install the Adobe Acrobat Reader 4 0 software using the custom CD ROM entitled Adobe Acrobat Reader 4 0 Installation Files PN 32198 000 that is provided along with your SmartModel product Even if you already have a previous version of the Reader software installed on your platform you should complete this step You can get additional free copies of the Acrobat Reader from Adobe s website at the following address http www adobe com The Acrobat Reader is required to view or print the SmartModel online documentation in Portable Document Format PDF April 2001 Synopsys Inc 13 Chapter 2 Installation Procedure SmartMode