Home

to manual

image

Contents

1. 8 9 Carefully remove contents from the package which may include fragile parts Carefully assemble the scale by placing the scale pan Place the scale in a firm and flat surface and avoid location where the scale maybe subject to vibration sunlight airflow contact with water and strong electromagnetic wave Level the scale by using the bubble level indicator if available and adjusting the feet of the scale Locate scale in the following condition Temperature 0 C 40 C Plug in the scale to a surge protected power outlet if using the AC adapter If using batteries carefully install the 4 AA batteries by opening the battery compartment cover and making sure the polarity is correct Press the ON OFF key in the front panel to turn the scale on and wait for it to finish initialization i e when the display shows a weight of 0 Let the scale warm up for minute before calibration and use Make sure any weight placed on the scale is not beyond the rated maximum IO If scale is not used for an extended period of time disconnect all power including the 4 AA batteries Calibration After all the preparation procedure has been performed remember the scale needs to warm up for minute follow the steps below for calibration 3 CON ON VI R If the scale is not already on press the ON OFF key to turn on the scale and warm up for minute Press the ON OFF key to turn scale off Making sure there is
2. OPK P S Series User Manual Warnings Avoid using the balance in any harsh environment Only trained professionals are allowed to do repair work e Turn power off before connecting disconnecting the power source Avoid overloading or dropping material onto the platform as that could damage the balance Do not spill liquids on the balance as that could damage the balance Material that has a static charge could influence the performance of the balance Electromagnetic interference can affect the reading of the balance Unplug the power before cleaning and use a piece of soft cloth do not use aggressive cleaning agent Make sure no liquid enters the balance Getting Startedassiueai keinen OVERVIEW eissie ea Contents esse eis PR PATATION ae een ANID PALI OU a as een yet Low Battery Indicator ss PUGH CTO essen ses sr 1roubleshoating zu ee Technical Support ms nn Overview Thank you for using Optima scales for your important application Here is the list of models this manual covers Model Max Weight grams Accuracy grams 250 500 250 500 OPK P 250 OPK P 2500 2500 5000 2 5 2500 2500 5 5000 5000 2 Note Plastic platter Stainless platter OPK P 5000 OPK S 250 OPK S 500 Contents Scale main unit Scale pan User Manual AC adapter 2V 100mA 4 x AA size battery not included Preparation T
3. a firm and flat surface and that there are no external interference Please revisit the Preparation section of this manual Also please make sure the calibration procedure has been performed correctly It won t hurt to run through the calibration process again when in doubt Q The scale does not turn on Make sure the power cord is plugged in and that there is power One easy way to test this is by connecting another appliance to the same outlet and see if it s operational Technical Support Please email support optimascale com if you have any further questions
4. no weight on the pan press the ON OFF key once to turn on the scale Press the TARE key once Press and hold the MENU key until the display show CAL Press the MENU key once and the displayed CAL flashes Place the calibration weight as shown on the display on the pan When display shows PASS the calibration procedure is completed If display shows the unit will turn off automatically After initialization is done put the calibration weight again to confirm the value If it s correct the calibration is done correctly If not repeat the calibration steps Basic Weighing After the scale has been properly calibrated the scale is now ready for use If scale is not on press the ON OFF key to turn the scale on 2 Make sure the display is showing O after initialization If not press the ZERO key to zero out the display 3 Place the object s of interest on the scale pan as close to the center as possible 4 Read the value on the display 5 Remember NOT to overload the scale since this may permanently damage the scale Units The available units are grams OZ and Carats Tare To tare follow the procedure below Make sure the scale 15 stabilized 2 Press the ZERO key Low Battery Indicator When the display shows a battery symbol it is time to replace the battery Troubleshooting Q The scale is not showing an accurate reading A Make sure the scale is placed on

Download Pdf Manuals

image

Related Search

Related Contents

CS-255DAB Mini-système CD Hi-Fi  『コッコでパン屋さん』を新発売  GUI User Guide - Borsa Italiana  CSR14_2_Swapnil  K-Tech News Vol.3 No.1  SBS TEBOOKUN50P mobile phone case  User's Manual - Divitec Camera Solutions  Gigabyte 6EA Network Card User Manual  Anthro Tablet Charging Cabinets  

Copyright © All rights reserved.
Failed to retrieve file