Home

Installation & operating instructions DPHM

image

Contents

1. DP H M Cj 2 2 B Label DP Product Label Material H Horizontal Construction M All hydraulic parts Stainless Steel 1 4301 AISI 304 with close coupled motor C Cast Iron pump casing Connections DIN connection size suction G 5 4 discharge G 1 2 Size Capacity in m3 h at Qopt 12 Number of stages B Design version B 5 2 Description of the product The horizontal multi stage centrifugal pump is designed for pumping clean or slightly aggressive watery mediums The pump is easy to install commission and operate The hydraulic assembly is driven by an electric motor All hydraulic parts of the pump are made of stainless steel Pump casings are available in stainless steel or cast iron 5 3 Intended use The pumps DPHM are suitable to transport and increase the pressure of cold and hot water without wear to parts within the indicated working range The transport of liquids with a different viscosity or density than water is possible as well For this a motor with an adjusted power could be required Ask DP Pumps or your distributor for advice Any other or further use of the pump is not in conformity with its intended use DP Pumps does not accept any liability for any damage or injury that results from this The pump is produced in accordance with the current standards and guidelines Use the pump only in a perfect technical state in conformance with the intended use described below The Intend
2. Horizontal multi stage centrifugal pumps series DPHM C Installation and operating instructions Table of Contents 10 11 Manual Introduction A PRETACE A EN NN TEN O O INTE 3 1 2 ICONS and SYM DO S ii peo Enait 3 Identification service and technical support 2 1 Obtaining data and information DPHM C 2 4 6 ooooonociicccconocccnnocinnonnccnonononnno cnn non cnn nn nn nnnn nr nr nnnnrnnnn 4 2 2 A ck Mees ed iaia a N a ev A 5 253 A O T T 5 2 4 Supplementary dOCUMENMtatiON oooonccccnnnccnococcnonanonono non onnnnnno nn nc an cnn rra carrera 5 Warranty Sl Terms Of Wa Yo A as a Meds 6 Safety and environment AN Generals AA 7 A O cians veast eventyhuee doce Peccessaekits E A 7 4 3 Safety POVISIO Singet ienn cee ee eae A ei ee ee ee AU en ie 7 44 Safety PreCautiOns ici ii ina ats Leta ee See 7 4 5 Environmental aspects sc scccccccceeceseesccen setae tects cede dae 8 Pump Introduction Br Model KO ico idas 9 5 2 Description of the product cian ais 9 5 37 InteMded USO ai A A A a A Tao soe a ee eave 9 e O NT 9 5 5 Measuring draining and VENting cccccccecceececeeeeceeeeeeceeeeeeesesaaaeeeeeeeaaeeeeeeseaaeeeeesenaeeeeeseeeeeeeeeeatees 10 5 0 gt WOFKING FANGS ci a 10 Transport 6 1 A shee apis tee dey ca Senta dee N a ost Base ton ga e Set oe Neca ce ee 11 O22 OA eS E lA sica 11 Installation instructions 7A SON UP the PUMA a eee 12 2 Electrical installation dicas
3. For example in particular non compliance can result in e failure of important pump system functions e failure of prescribed maintenance and servicing practices e injury to persons by electrical mechanical and chemical effects e hazard of the environment due to leakage of hazardous substances e explosions Depending on specific activities extra safety measures may be required Contact DP Pumps if a potential danger arises during use IS ATTENTION The owner of the product is responsible for compliance with the local safety regulations and internal company guidelines IS ATTENTION Not only must the general safety instructions laid down in this chapter on Safety be complied with but also the safety instructions outlined under specific headings 4 2 Users All personnel involved in the operation maintenance inspection and installation of the product must be fully qualified to carry out the work involved and be aware of all applicable responsibilities authorisations and super visions If the personnel in question is not already in possession of the required know how appropriate training and instruction must be provided If required the operator may commission the manufacturer supplier to take care of such training In addition the operator is responsible for ensuring that the contents of the operating instructions are fully understood by the responsible personnel 4 3 Safety provisions The product
4. WARNING Surfaces of a pump can be hot after continuous operation WARNING Make sure that no one can be near rotating components when starting a pump WARNING Handle a pump with dangerous liquids with the utmost care Avoid danger for persons or the environment when repairing leakages draining liquids and venting It is strongly recommended to place a leakage tray under the pump WARNING Immediately following completion of the work all safety relevant and protective devices must be re installed and or re activated WARNING Please observe all instructions set out in the chapter Commissioning Start up before returning the product to service gt PEPE amp 4 5 Environmental aspects 4 5 1 General The products of DP Pumps are designed to function in an environmentally friendly way during their entire lifetime Therefore when applicable always use biodegradable lubricants for maintenance OY ENVIRONMENTAL INSTRUCTION amp amp Always act according to the laws by laws regulations and instructions with respect to health safety and the environment 4 5 2 Dismantling The owner is responsible for the dismantling and environmentally friendly disposal of the product ENVIRONMENTAL INSTRUCTION cA amp Ask at the local government about the re use or the environmentally friendly processing of discarded materials 5 Pump Introduction 5 1 Model key Table 5 Model key Example
5. PANES 7 CAB g O o o e oe o e o e o o gee Ko o o Jol om o o o o 0 8 won o o 20 o o 20 LO Lo o o o o Figure 9 Example installation of a pump in suction operation 20131397 A 7 3 2 Open the discharge shut off valve B Remove the fill plug C Put a funnel into the port C and completely fill the pump with the liquid to be pumped e Vent the pump on discharge side for example via a venting valve D on discharge side see Figure 9 Example installation of a pump in suction operation e Make sure all air is removed from the pump e Close the venting option on discharge side Close the discharge shut off valve B Close the fill plug C Start the pump Start the motor Gradually open the discharge shut off valve B Make sure the pump started correctly within 20 seconds if not then s Switch off the motor e Re prime the pump Start the motor again Switch the pump off and on for 2 3 times after running continues for 30 seconds and make sure all air is removed from the pump 8 Operation 8 1 Operation The pump is controlled externally and therefore does not need any operation guidance 15 16 9 Maintenance 9 1 Introduction WARNING Observe the general safety precautions for installation maintenance and repair Regular maintenance is necessary for the correct operation of a pump Please contact your supplier fo
6. before putting into operation 11 12 7 1 Installation instructions Setting up the pump ATTENTION Avoid stress in the pump casing caused by misalignment in the piping system Please see table below ATTENTION Pumps which do not stand steady or stable on their own should be mounted on a rigid and stable base ATTENTION Locate the pump at the place with the lowest risk for noise nuisance TPO PO 20200000 Me ls hoe AA 20 20 C 0 O O Q O O O Figure 5 DPHM C not connected 20131398 Place and install the pump on a level stable surface in a dry and frost proof room Place the pump as close to the source tank as possible Make sure that sufficient air can reach the cooling fan of the motor For this purpose the free space above the cooling fan should be at least 1 4 of the diameter of the fan hood air intake It is advised to install a shut off valve on the supply and on the delivery connection of the pump To avoid medium flowing back through the pump when idle make sure a non return valve is installed 6 To the suction line should apply 1 2 3 Figure 6 Terminal box and fan hood sticker 100 airtight No camber Running from the lowest point in the tank straight to the pump Provided with a foot valve that shuts off well making sure that the suction line is always filled with water If the diameter of the suction line is larger t
7. following icons and symbols are used gt E WARNING Danger of electric Voltage Safety sign according to IEC 417 5036 WARNING Operations or procedures if carried out without caution may cause personal injury or damage to the product General hazard sign according to ISO 7000 0434 IS ATTENTION Is used to introduce safety instructions whose non observance may lead to damage to the product and its functions OY ENVIRONMENTAL INSTRUCTION Remarks with respect to the environment 2 Identification service and technical support 2 1 Obtaining data and information DPHM C 2 4 6 i The name plate indicates the type series size main E operating data and identification number Please quote this information in all queries repeat orders and particularly when ordering spare parts If you need any additional information or instructions E Q exceeding the scope of this manual or in case of IS damage please contact DP Pumps nearest customer service centre Q o Figure 2 Duty point 3 DPHMC 4 6 B acom El 1 1kW 50Hz ai oa 10 290048451060M Seal Ca Ce NBR EPDM 5 a 43mh nfix 2880rpm o H 404m T 10 60 C gt PO p PN10 J Prod 07 2014 1103153 4682 CE a i Figure 1 Pump with motor 3 Table 1 Description nameplate Indication Meaning DPHMC 4 6 B Model key design version B 1 1 kw Installed motor power 50 Hz Nominal frequency ID 290048451060M Pump ID Q 4 3 m h Optimum capacity
8. has been designed with the greatest possible care Original parts and accessories meet the safety regulations Modifications in the construction or the use of non original parts may lead to a safety risk IS ATTENTION Make sure that the product operates within its working range Only then the product performance is guaranteed 4 3 1 Labels on the product The icons warnings and instructions applied to the product are part of the safety provisions The labels may not be removed or covered Labels must remain legible during the entire life of the product Replace damaged labels immediately 4 4 Safety precautions 4 4 1 During normal use e Contact the local electricity company for questions about the power supply d Protect the parts that can become hot making direct contact impossible e When applicable always place undeformed coupling guards to protect the coupling before putting the pump into use Make sure that the coupling guards are never in contact with the rotating coupling Always close the terminal box of the motor Always close the control panel where applicable cb 4 4 2 During installation maintenance and repair Only authorised personnel may install maintain and inspect the product and repair electrical components Observe the local safety regulations WARNING Always disconnect the energy supply to the product first before installation maintenance and repairs Secure this disconnection
9. running at ng see fig 2 Duty point H 40 4m Optimum head running at ng see fig 2 Duty point PO Purchase order number Prod 07 2014 1103153 4682 Production week year and production serial number gt as built file Seal Ca Ce NBR EPDM Mechanical Seal Surface Code and elastomer and pump elastomer see table 2 2 Seal codes n fix 2880 rpm Rotation speed indication at which Q H are given T 10 60 C Temperature range p PN10 Pressure Class connection 2 2 Seal codes Table 2 Material code shaft seal Code acc to EN 12756 Description Material Note B Spring loaded ring Carbon graphite Ca Resin impregnated V Seat ring Ceramic Ce Aluminium oxide E Elastomers EPDM EPDM Ethylene propylene rubber P NBR NBR Nitrile butadiene rubber F Spring CrNi steel F Other metal parts CrNi steel 2 3 Current 2 4 Supplementary documentation 2 3 1 Nominal current The nominal allowable current of the motor is stated on the motor plate This shows the nominal working range of the motor and can be used to protect the motor Measuring the actual current of the pump during operation can be used to pre set the motor protection switch to protect the pump motor combination This current value can also be used to determine the proper electrical equipment such as variable frequency drive main switch wiring diameter etc A 2 3 2 Motor protection Standard single phase motors are delivered including motor protection The m
10. 13 73 COMMISSIONING A aaae a aaa NEE A A sland evgqcebeedetenediite cbececueuslavgguedecnegedyestegedets site 13 Operation 8 1 Oper coin tiaan aa aaa ae adeante e 15 Maintenance Solo INTO UCA e an AA RAN 16 9 2 Maintaining the pump for an extended period of non operation ooconniccninocinnoccccnannnononano nano no nana nonno no 16 Failures TOA a OEE E A E E E ba 17 10 2 Torques of vent and draining plUYS coooncccnnccnnnncccnnnonnnonannnononcnnno nc n nn nro rr rn rn 18 Annexes 11 1 EC decl ration of Conformity vitoria ia 19 1 1 1 Manual Introduction Preface This manual contains important information for reliable proper and efficient operation Compliance with the operating instructions is of vital importance to ensure reliability and a long service life of the product and to avoid any risks The first chapters contain information about this manual and safety in general The following chapters provide information about normal use installation maintenance and repairs of the product The annex contains the declaration s of conformity 1 2 Make yourself familiar with the content Accurately follow the directions and instructions Never change the sequence of the operations to be carried out Keep this manual or a copy of it together with the logbook in a fixed place near the product which can be accessed by all personnel Icons and symbols In this manual and in all accompanying documentation the
11. ater meter Leakage 10 2 plugs Table 9 Torques YN c e 2 a G YN 5 5 ae 8 55 a eZ PEHD G1 4 3 AISI G1 4 15 Pump failure Torques of vent and draining Figure Locations E and F in fig 3 DPHM C 2 4 6 Contact the supplier 11 Annexes 11 1 EC declaration of conformity DP Pumps Kalkovenweg 13 2401 LJ Alphen aan den Rijn The Netherlands Tel 31 0 172 48 83 88 Hereby declares as manufacturer entirely on his own responsibility that the products Horizontal multi stage centrifugal pumps series DPHM C Serial number 18 2012 1000000 0001 52 2016 9999999 9999 to which this declaration refers is in accordance with the following standard EN 809 1998 A1 2009 AC 2010 according to the provisions of the harmonized standard for pumps and which implies the regulations of Machine directive 2006 42 EC EMC directive 2004 108 EC in the most recent form The pump is subject to this declaration of conformity as a stand alone product Make sure the appliance or installation in which the pump is built in has got a declaration of compliance with the directives listed above for its complete assembly y f f Wa oe LK A Alphen aan den Rijn 01 03 2014 Authorized representative W Ouwehand technical director 19 dp pumps dp pumps P O Box 28 2400 AA Alphen aan den Rijn The Netherlands t 31 172 48 83 88 f 31 172 46 89 30 dp dp pumps
12. com www dp pumps com 06 2015 BE00000554 D EN Can be changed without prior notice Original instructions
13. e noise emission of the motor is documented IS ATTENTION The temperature difference between the medium and the pump should never exceed 60 C The pump must be filled heated up slowly in any case where the difference between pump and medium is more then 30 C to avoid any chance of a thermal shock For minimum maximum flow at medium temperature of 20 C see table 7 Minimum maximum capacity Qmin max for higher temperatures see figure 4 Minimum capacity vs temperature in of Q optimum Table 7 Minimum maximum capacity Q min max size Gmin max M h 2 pole 50 Hz 60 Hz Min Max Min Max 2 0 2 3 3 0 2 4 0 4 0 4 6 5 0 5 7 8 6 0 6 9 0 0 8 10 8 11 4 Q 10 5 10 9 5 4 a 40 45 50 55 T C 60 Figure 4 Minimum capacity vs temperature in of Q optimum 4431 6 Transport 6 1 Transport Always observe the directions as indicated on the installation by means of stickers 1 Transport the installation in the position as indicated on the pallet or packaging 2 Make sure that the installation is stable 3 Observe the instructions on the packaging if present 6 2 Storage Fill the pump with glycol in order to protect it against the risk of frost Table 8 Storage Storage tambient C Max rel humidity 10 40 80 at 20 C not condensing 6 2 1 Inspection during storage 1 Turn the shaft every three months and just
14. ed in accordance with its designated use as described in the following sections of this manual The limits stated in the data sheet must not be exceeded under any circumstances The warranty becomes invalid if one or more of the points below occur e The buyer makes modifications himself e The buyer carries out repairs himself or has these carried out by a third party The product has been handled or maintained improperly e The product has non original DP Pumps spare parts fitted DP Pumps repairs defects under warranty when e They are caused by flaws in the design the material or the production e They are reported within the warranty period Other terms of warranty have been included in the general terms of delivery which are available upon request 4 Safety and environment 4 1 General This DP Pumps product has been developed using state of the art technology it is manufactured with utmost care and subject to continuous quality control DP Pumps does not accept any liability for damage and injury caused by not observing the directions and instructions in this manual or in cases of carelessness during the installation procedure use and maintenance of the product Non compliance with safety instructions can jeopardize the safety of personnel the environment and the product itself Non compliance with these safety instructions will also lead to forfeiture of any and all rights to claims for damages
15. ed use as laid down in ISO 12100 2010 is the use for which the technical product is intended according to the specifications of the manufacturer The use of the product has been described in the sales brochure and in the user manual Always observe the instructions given in the user manual When in doubt the product must be used as becomes evident from its construction version and function 5 4 Operation 20131394 Figure 3 DPHM C 2 4 6 The rotating impeller causes the pressure at the inlet of the impeller to drop This decrease in pressure creates the flow through the suction connection A Every stage B consists of an impeller and a diffusor The capacity of the pump is determined by the size of the passageway of the stage The pressure of the stage is determined by the diameter of the impeller Because of the modular type of construction it is possible to choose the number of impellers most suited to the required duty point After leaving the last impeller the medium flows between the pump stages and the outer sleeve C and exits the pump at the discharge connection D Cb 10 5 5 Measuring draining and venting The pump is provided with plugs for measuring draining and venting Connection E is meant to fill and vent the pump or to measure the inlet suction pressure using a G Y connection Connection F is meant to drain the pump or to measure the discharge pressure using a G Y connection 5 6 W
16. han the pump suction connection then install an eccentric adapter in order to prevent air pockets and swirling Indicators 20131395 The arrow A on the fan hood indicates the rotating direction of the motor in case of a 3 phase motor 7 1 2 Install bypass Install a bypass if the pump may operate against a closed valve for a long period The required capacity of the bypass is at least 10 of the maximum volume flow At high operating temperatures a higher volume flow is required With temperatures above 60 C the required capacity is more than 10 ES ATTENTION Do not make use of quick closing valves and or shut off valves to prevent pressure impulses in the pump and in the lines as a result of changes in the flow rate 7 2 A Electrical installation WARNING In accordance with the local regulations only authorised personnel is allowed to make electrical connections to the motor Example may differ upon chosen motor ES ATTENTION Connect the motor according to figure 7 Motor connections and always check the rotation direction Electrical connections s Make sure that the motor specifications correspond with the power supply to which the pump motor is connected Consult Electrical diagrams for the correct connection diagram e Connect the motor using a motor safety switch 3x 400V OVERLOAD PROTECTION lt SIn N N 230 400V U1 l O O e Overload protection Q
17. orking range Table 6 General working range specification Pump type DPMM noe Ambient temperature C 20 upto 30 50 11 75 Medium temperature C 10 up to 60 Minimum inlet pressure NPSH eq 1M Viscosity cSt 1 100 a Density kg m 1000 2500 z Cooling forced motor cooling Minimum frequency Hz 30 Maximum frequency Hz 60 5 oO Maximum number of starts see motor data sheet Noise emission al see motor data sheet Allowable size of solids pumped 5 um to 1 mm 1 Avoid freezing the pump 2 Ifthe ambient temperature exceeds the above value or the motor is located more than 1000 m above sea level the motor cooling is less effective and could require an adapted motor power Please contact your supplier for more detailed advice 3 Single phase motors are equipped either with a ther mal circuit breaker or motor winding protection see 2 3 2 Motor protection Please contact your supplier for more detailed information about your motor protec tion 4 Deviation in viscosity and or density could require an adapted motor power Please contact your supplier for more detailed advice 5 Pumps that are intended for 50 Hz operation may not be connected to 60 Hz power supply 6 Frequent start stops in particular in combination with higher pressure differences Ap may result in a short ened product lifetime Consult your supplier for such applications 7 Only th
18. otor protection is provided either by a thermal circuit breaker or by a motor winding protection WARNING Not only the motor but also the pump has to be protected in its application Table 3 Type of protection z a 8 s a gt gt E 9 o a hoj z 9 c os E O o oO S O 20 2 25 lo so v ey SE 8 3 as a2 a ra 1 Thermal 20 30 Thermal Manual circuit breaker box 2 Winding 20 50 Motor Automatic protection winding Please contact your supplier for more detailed information about your motor protection Apart from this manual the documentation given below is also available Table 4 Supplementary documentation Document Code General terms of delivery 119 1998 DPHM C 2 4 6 Technical Data 50 60 Hz Version B 97004494 See also www dp pumps com 3 Warranty 3 1 Terms of warranty The warranty period is settled by the terms of your contract or at least by the general terms and conditions of sales IS ATTENTION Modifications or alterations of the product supplied are only permitted after consultation with the manufacturer Original spare parts and accessories authorized by the manufacturer ensure safety The use of other parts can invalidate any liability of the manufacturer for consequential damage IS ATTENTION The warranty relating to the operating reliability and safety of the product supplied is only valid if the product is us
19. p O No No 230V WITHOUT OVERLOAD PROTECTION lt N 400 692V sO Os sQ Os lt OO N Figure 7 Motor connections 7 3 A Commissioning WARNING The pump must be switched off when it is not completely filled up N Os SO Oz lt gt O No No 20140034 ATTENTION Check the direction of rotation according to fig 6 Terminal box and fan hood sticker In case of a 3 phase motor the rotation direction can be changed by exchanging two of the 3 phases cb 13 14 7 3 1 Prime the pump PEE Lo So 0 0 00 0 90 70 90 8 10 0 lt Figure 8 Example installation of a pump S under pressure operation Q A e e Close the discharge shut off valve B e Close the suction shut off valve A e Unscrew the fill plug C e Gradually open the suction shut off valve A until the liquid flows from the fill plug C e Close the fill plug C e Open shut off valve B s Vent the pump on discharge side for example via a venting valve D on discharge side see Figure 8 Example installation of a pump under pressure operation e Close the venting option on discharge side e Close the discharge shut off valve B repeat these steps until all air is removed from the pump e Make sure that the suction shut off valve is entirely open
20. r maintenance of the pump 9 2 Maintaining the pump for an extended period of non operation Turn the shaft every three months This protects the seals from seizure Protect the pump if there is a risk of frost Proceed as follows Close all pump valves Drain each pump and or the system Remove all plugs from the pump Open the shut off and fill air vent plug if present Pdon gt 1 period may vary per application or medium Please consult your sales representative for application details 10 Failures 10 1 A Problem The motor is not running Failure table WARNING repair Observe the general safety precautions before installation maintenance and Possible cause No voltage on the power terminal Possible solution Check the power supply Checkpoints gt Circuit id Main switch id Fuses Check the motor safety relay e Earth leakage switch e Protective relay Thermal motor safety switch triggered Disconnect the motor from the main Let the motor cool down The thermal motor safety will reset it self Contact the supplier if this problem occurs often Check the free space of the motor and pump the ambient temperature and the medium temperature The motor is running but the pump does not work Pump is vibrating and or noisy Internal failure There is no water in the pump Contact the supplier Fill and vent the pump No supply of the medi
21. um Make sure there is suffi cient supply Check for blockages in the supply line Broken motor bearing Contact the supplier Available NPSH too low cavitation Improve suction condition Pump does not work in its working range Select another pump or adjust the system to work within its working range Pump supplies insufficient capacity and or pressure Outlet and or inlet shut off valve is closed Open both shut off valves There is air in the pump Vent the pump The suction pressure is insufficient Increase the suction pres sure Pump rotates in the wrong direction Change over L1 and L2 of the three phase supply 17 Foot valve blocked Clean the foot valve The suction line has not been vented Vent the suction line Air bubble in the suction line Install the suction line with pump end higher than the other end 18 Problem Pump supplies insufficient capacity and or pressure Possible cause Pump sucks air because of leakage in the suction line Possible solution Repair the leakage Checkpoints Water flow too low So air bubbles clog up in the pump Make sure the flow increases or use a smaller pump The diameter of the suc tion line is too small Increase the diameter of the suction line Capacity of water meter in the supply line is too small Increase the capacity of the w

Download Pdf Manuals

image

Related Search

Related Contents

Multi Layer Perceptron with Back Propagation User Manual  Fujitsu PLL Frequency Synthesizer Evaluation Tool (Version 5.0  取扱説明書 (1.94 MB/PDF)  Pinnacle Design TV24203 User's Manual  Miele DA 8-2 User's Manual  Toshiba 32 154W CRT Television User Manual  Operating Instructions  Fring for Windows Mobile - 3.34 User Guide  Philips RI1760 Blender  User Manual(MAI-P) revised  