Home

ELATION DW PROFILE - USER MANUAL 1.0

image

Contents

1. sediments Never remove the ground prong from the power cable 24 DW PROFILE User Manual 1 0 EtATION TECHNICAL SPECIFICATIONS FEATURES 17 27 Manual Zoom 4 Blade Manual Framing Shutters Variable Color Temperature Settings 3 000K 6 000K Manual and DMX Controlled Strobe and Dimmer Flicker Free Operation for TV and FILM SOURCE 250W Dynamic LED Engine 100 000 Hour Average LED Life PHOTOMETRIC DATA 20 200 LUX 1877 FC 8 2 2 5M 17 Full On 9 640 LUX 896 FC 28 2 2 5M 27 Full On EFFECTS Variable Strobe Settings 1 18 fps Electronic Dimming 0 100 GOBOS supports B Size Glass Metal HT Transparency Gobos Gobo Size OD 86mm IA 64mm Thickness O 15mm CONTROL CONNECTIONS 7 DMX Channel Modes 2 3 8 Manual Zoom Manual and DMX Color Temperature and Dimmer 4 Button and 2 Dial Control Panel LCD Menu Display 3pin and 5pin DMX In Out powerCON In SIZE WEIGHT Length 30 1 764mm Width 12 8 325mm Vertical Height 18 0 458mm Weight 30 0 Ibs 13 6 kg ELECTRICAL THERMAL 100 240V 50 60Hz 300W Max Power Consumption 14 to 113 F 10 to 45 C APPROVALS RATINGS CE Approved IP20 Rated INSTALLATION Rigging Clamp or Stand Not Included Working Position Any 360 INCLUDED ITEMS 1 powerCON Cable 1 3pin XLR Cable 1 Safety Cable www elationlighting com Please Note Specifications and improvements in the design of this unit an
2. to prevent any fire hazard The fixture must be installed in a location with adequate ventilation at least 1 5 feet 5m from adjacent surfaces Be sure no air ventilation slots are blocked DO NOT attempt installation and or operation without knowledge how do so DO NOT permit operation by persons who are not qualified to operate this type of fixture Most damages are the result of operations by nonprofessionals Consistent operational breaks may ensure the fixture will function properly for many years fo come DO NOT shake fixture avoid brute force when installing and or operating fixture Always install the fixture with an appropriate safety cable When installing the fixture in a suspended environment always use mounting hardware that is no less than MIO x 25 mm also be sure the hardware is insert in the pre arranged screw holes in the bracket of the fixture Use the original packaging and materials to transport the fixture in for service DO NOT TOUCH the housing bare hand during its operation Turn OFF the power and allow approximately 15 minutes for the fixture cool down before replacing Or serving 8 DW PROFILE User Manual 1 0 FIXTURE OVERVIEW e wr oe LCD Menu Function Display UP Button DOWN Button MODE ESC Button ENTER Button COLOR TEMPERATURE DIAL DIMMER DIAL BLADE SHUTTERS GOBO Slot Holder Optional ZOOM Buttons www elationlighting com 12 13 14 15 16 18 19 2
3. 14 amp 15 Auto Pro Part 1 is Program 2 Auto Pro Part 2 is Program 3 Auto Pro Part 3 is Program 6 The 3 Slave groups run Auto Program in certain time segments as shown in the following picture Part 1 Pe serit wb Sw Part 2 M me me es Part 3 22 DW PROFILE User Manual 1 0 EtATION www elationlighting com Que g g DMX CHANNEL FUNCTIONS AND VALUES ELATIONO DW PROFILE DMX Channel Values Functions 8 DMX Channels opecifications are subject to change without any prior written notice 001 WHITE LED 0255 Cool White 0 Black 255 100 Cool White mun 0255 255 Warm White O Black 255 100 Warm White COLOR TEMPERATURE 1 0 RO FUNCTION 1 125 Color Temperature 1 3 200K 255 6 000K COLOR TEMPERATURE 2 ONO FUNCTION E NO FUNCTION 32 63 NO FUNCTION DIMMER INTENSITY o 0 255 Intensity O to 100 D 0 255 255 FINE Intensity O to 100 DIMMING CURVES 128 170 ARCHITECTURAL 171 213 THEATRE 214 255 Default to Unit Dimming Curve Setting 23 DW PROFILE User Manual 1 0 www elationlighting com CLEANING AND MAINTENANCE CAUTION Disconnect from mains before starting maintenance operation CLEANING Frequent cleaning is recommended to insure proper function optimized light output and an extended life The frequency of cleanin
4. Clear fixture last run time Time can only be cleared after the timer password is entered Info Tempinfo HeadTemp Displays temperature of the fixture Info Soft Ver Displays software version of the fixture Persnal Stat Set Addr DMX Define desired DMX address via an external controller Persnal Stat Set NoDMXSta Define how fixture operates if NO DMX signal is detected Persnal Disp Set Off Time Define how many minutes before the LCD Menu display will automatically shut OFF Persnal Disp Set Key Lock When ON Control Panel buttons lock automatically after exiting main menu for 15 seconds To unlock keep MODE ESC button pressed for 3 seconds Persnal Temp C F Define how fixture displays internal temperature Celsius or Fahrenheit Persnal ResetDef When ON all factory settings are restored 19 DW PROFILE User Manual 1 0 www elationlighting com ManCntrl ManCntrl Adjust functions manually Mode Set UserMode select DMX channel modes Dimming DimModes select dimming modes Standar stage TV Archite Theatre EditProg Sel Prog select one of the 10 user defined internal Auto Programs EditProg EditProg Edit any of the 10 user defined internal Auto Programs EditProg EditScen Edit any of the 290 scenes of the internal Auto Programs EditProg RecChniri The fixture features an integrated DMX reco
5. 0 GEL FRAME Optional Mounting Yoke 3pin DMX OUT 5 DMX OUT 5pin DMX IN 3pin DMX IN Safety Cable Eyelet powerCON In Fuse Power Switch DW PROFILE User Manual 1 0 www elationlighting com FIXTURE INSTALLATION CAUTION Please consider the GB7000 15 EN60598 2 17 and the other respective national norms during the installation The installation must only be carried out by a gualified person CAUTION T he electric connection must only be carried out by a qualified electrician EI CAUTIONS For added protection mount the fixture in areas outside walking paths seating areas or in areas were unauthorized personnel might reach the fixture Ambient operating temperature range for this fixture is 14 to 113 F 10 to 45 Do not use the fixture under or above this temperature Before mounting the fixture to any surface make sure the installation area can hold a minimum point load of 10 times the weight of the fixture 300 15 136 kg Fixture installation must always be secured with a secondary safety attachment such as an appropriate safety cable Never stand directly below the device when mounting removing or servicing FLAMMABLE MATERIAL WARNING Keep fixture at least 1 5 ff 1 5m away from any flammable materials decorations pyrotechnics etc 10 DW PROFILE User Manual 1 0 www elationlighting com MOUNTING POINTS e Overhead mounting requires extensive experien
6. ELATION DW PROFILE user manual 1 0 DW PROFILE User manual 1 0 PROFESSIONAL ELATION www elationlighting com 2014 ELATION PROFESSIONAL all rights reserved Information specifications diagrams images and instructions herein are subject to change without notice ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged All non ELATION brands and product names are trademarks or registered trademarks of their respective companies ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation of this product Elation Professional USA 6122 S Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www elationlighting com info elationlighting com Elation Professional B V Junostraat 2 6468 EW
7. Kerkrade Netherlands 31 45 546 85 66 31 45 546 85 96 fax www elationlighting eu info elationlighting eu 2 DW PROFILE User Manual 1 0 www elationlighting com CONTENTS 4 man Fixture Overview 4 Fixture Installation 10 Understanding DMX 13 28 DMX Channel Functions And Values Technical Specifications 225 13 17 Cleaning and Maintenance 24 25 Optional Accessories 3 DW PROFILE User Manual 1 0 www elationlighting com GENERAL INFORMATION INTRODUCTION Congratulations you have just purchased one of the most innovative and reliable lighting fixtures on the market today The DW PROFILE has been designed to perform reliably for years when the guidelines in this booklet are followed Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit These instructions contain important information regarding safety during use and maintenance UNPACKING Thank you for purchasing the DW PROFILE by Elation Professional Every DW PROFILE has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your unit for damage and be sure all accessories necessary operate the unit have arrived intact In the event damage has been found or parts are missing ple
8. PROFILE can be controlled via DMX 512 protocol and the DMX is set via the control menu DATA CABLE DMX Cable REQUIREMENTS For DMX and Master Slave Operation Your fixture and your DMX controller require a standard 3pin or 5pin XLR connector for data input and data output see figure below If you are making your own cables be sure use two conductor shielded digital DMX cable rated at 120 ohms this cable is designed for DMX transmission and may be purchased from your Elation dealer or at most professional lighting retailers Your cables should be made with male and female XLR connector on either end of the cable Also remember that a DMX line must be daisy chained and cannot be split unless using an approved DMX splitter such as Elation s Opto Branch 4 Opto Branch 8 or DMX Branch 4 M 13 DW PROFILE User Manual 1 0 www elationlighting com DMX Output DMX Input DMX Output DMX Input 3 Pin XLR Socket 3 Pin XLR Socket 5 Pin XLR Socket 5 Pin XLR Socket 1 Ground 1 Ground 2 Data o e 2 Data o 3 Data 3 Data 4 Open 5 Open Be sure to follow the above figure when making your own cables Do not use the ground lug on the XLR connector Do not connect the cable s shield conductor the ground lug or allow the shield conductor come in contact with the XLR outer casing Grounding the shield could cause a short circuit and erratic behavior DMX 512 CONTROLLER CONNECTION C
9. am 1 10 Program 3 EditProg EditProg Prog 10 scene 001 EditScen Scene 250 OPTIONS VALUES Default Settings in BOLD Adjust Functions Manually DMX Channel Modes Dimming Modes select Programs To Be Run ProgTest 101 Testing Program EdStep 01 5015 Program In Loop EdStep 64 S64SC xx Save and Exit Cool Cool 200 Save and Automatically Return InByOut Time xx xs Manual Scenes Edit RecCn rl Automatic Scenes Recorder FuncMode Address Define desired DMX address via the Control Panel FuncMode ValuDisp Disolay DMX 512 value of each channel FuncMode SetSlave Define fixture slave mode Slavel Slave2 Slave3 FuncMode AutoProg Define fixture mode Master or Alone for running Auto Programs Select desired internal programs under Select Program set the number of steps under Edit Program and edit individual scenes under Edit Scenes 18 DW PROFILE User Manual 1 0 www elationlighting com Info Timelnfo Cur Time Displays fixture run time from last power ON The counter is reset after each time the fixture is powered OFF Info Timelnfo TotalHrs Displays fixture total run time Info Timelnfo Last Hrs Displays fixture run time for a given period of time i e rental period This counter can be reset Info Timelnfo TimePass Displays timer password 038 Info Timelnfo Clr Last
10. ase contact our customer support team for further instructions Please do not return this unit to your dealer without first contacting customer support at the number listed below Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS 1 3pin DMX Cable 1 powerCON Cable e 1 Safety Cables Manual amp Warranty Card gt MANUAL UPDATES Please check www elationlighting com for the latest updated version of this manual 4 DW PROFILE User Manual 1 0 www elationlighting com CUSTOMER SUPPORT Elation Professionale provides a customer support line to provide set up help and to answer any question should you encounter problems during your set up or initial operation You may also visit us on the web at www elationlighting corn for any comments or suggestions For service related issue please contact Elation Professional6 ELATION SERVICE USA Monday Friday 8 00am to 5 00pm PST Voice 323 582 3322 Fax 323 832 9142 E mail support elationlighting com ELATION SERVICE EUROPE Monday Friday 08 30 to 17 00 CET Voice 31 45 546 85 30 Fax 31 45 546 85 96 E mail support elationlighting eu WARRANTY REGISTRATION The DW PROFILE carries a two year 730 days limited warranty Please fill out the enclosed warranty card to validate your purchase All returned service items whether under warranty or not must be freight pre paid and accompany a return au
11. ce including amongst others calculating working load limits installation material being used and periodic safety inspection of all installation material and the device If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury e Fixture is operational in the specific mounting positions as illustrated below er SAFETY CABLE al yi di eJ Always use Sdfety Cable whenever installing this fixture in a suspended environment to ensure the fixture will not drop if the clamp fails 11 DW PROFILE User Manual 1 0 www elationlighting com CLAMP MOUNTING The DW PROFILE includes an adjustable mounting yoke and safety cable rigging point attached to the fixture see the illustration below When mounting this fixture to truss be sure to secure an appropriately rated clamp not included to the yoke using an MIO screw fitted through the center hole of the clamp Be sure to attach the included Safety Cable to the fixture using the safety cable rigging point SECURING Regardless of the rigging option you choose for your DW PROFILE always be sure to secure your fixture with a safety cable The fixture provides a built in rigging point for a safety cable on the hanging bracket as illustrated above Be sure to only use the designated rigging point for the safety cable and never
12. ce of purchase by acceptable evidence at the time service is sought B For warranty service send the product only to the Elation Professional amp factory All shipping charges must be pre paid If the requested repairs or service including parts replacement are within the terms of this warranty Elation Professional amp will pay return shipping charges only to a designated point within the United States If the entire instrument is sent it must be shipped in its original package No accessories should be shipped with the product If any accessories are shipped with the product Elation Professional amp shall have no liability what so ever forloss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number has been altered or removed if the product is modified in any manner which Elation Professional amp concludes after inspection affects the reliability of the product if the product has been repaired or serviced by anyone other than the Elation Professionale factory unless prior written authorization was issued to purchaser by Elation Professional amp if the product is damaged because nof properly maintained as set forth in the instruction manual D This is not a service contract and this warranty does not include maintenance cleaning or periodic check up During the period specified above Elation Professional amp will replace defective parts at its expense and will absorb all exp
13. d this manual are subject to change without any prior written notice 25 DW PROFILE User Manual 1 0 www elationlighting com PHOTOMETRIC DATA a Beam 2 5m 5m 7 5m MIN ZOOM ft ft m T Distance 2 5 8 2 5 16 4 9 24 6 17 Beam Diameter MAX ZOOM ft m ft Distance 2 5 8 2 i 16 4 ar team Demeter 12 3 24 79 ase WARM WHITE 4406 409 Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice 26 DW PROFILE User Manual 1 0 www elationlighting m 227 g g co DIMENSIONAL DRAWINGS 1 8 9 3 235mm ill TE ri LI TR 12 0 3 6 305 4mm 218mm 12 8 E IH 8 0 325mm da E 210mm e 42 rae Please Note Specifications and improvements the design of this unit and this manual are subject to change without any prior written notice 27 DW PROFILE User Manual 1 0 www elationlighting com OPTIONAL ACCESSORIES Gm Spin PRO DMX Cable 25 5m Spin PRO DMX Gabi Po A Gm Spin PRO DMX Cable 28 DW PROFILE User Manual 1 0
14. een PIN 2 DMX Nas and PIN 3 DMX of the last fixture 5 XLR CONNECTORS some manufactures use XLR connectors for DATA transmission in place of 3pin opin XLR fixtures may be implemented in a 3pin XLR DMX line When inserting standard 5pin XLR connectors in to a 3pin line a cable adaptor must be used these adaptors are readily available at most electric stores The following chart details a proper cable conversion 3 Pin XLR to 5 Pin XLR Conversion Conductor 3 Pin XLR Female Out 5 Pin XLR Male In Data Compliment signal Pin 2 Data True signal Pin 3 Not Used Pin 4 Do Not Use Not Used BENE Pin 5 Do Not Use 15 DW PROFILE User Manual 1 0 www elationlighting com DMX ADDRESSING fixtures should be given a DMX starting address when using a DMX controller so the correct fixture responds to the correct control signal This digital starting address is the channel number from which the fixture starts to listen to the digital control information sent out from the DMX controller The allocation of this starting DMX address is achieved by setting the correct DMX address on the digital display located on the back of the fixture You can set the same starting adaress for all fixtures or a group of fixtures or set different address for each individual fixture Be advised that setting all fixtures to the same DMX address will subsequently control all fixtures in the same fashion in oth
15. enses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of Elation Professionale under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of Elation Professional amp All products covered by this warranty were manufactured after January 1 1990 and bare identifying marks to that effect E Elation Professional amp reserves the right to make changes in design and or improvements upon its products without any obligation to include these changes in any products theretofore manufactured F No warranty whether expressed or implied is given or made with respect fo any accessory supplied with products described above Except to the extent prohibited by applicable law all implied warranties made by Elation Professional in connection with this product including warranties of merchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or fitness shall apply to this product after said period has expired The consumer s and or Dealer s sole remedy shall be such repair or replacement as is expressly provided above and under no circumstances shall Elation Professionale be liable for any loss or damage direct or consequential arising out of the use of or inability To use this product G This warranty is
16. er words changing the settings of one channel will affect all the fixtures simultaneously If you set each fixture to a different DMX each unit will start to listen to the channel number you have set based on the quantity of control channels DMX channels of each fixture That means changing the settings of one channel will only affect the selected fixture In the case of the DW PROFILE when in the 8 Channel Mode you should set the starting DMX address of the first unit to 1 the second unit to 9 1 8 the third unit to 17 9 8 and so on Note During start up the DW PROFILE will automatically detect whether a DMX data signal is being received or not If DMX data signal is being received the display will show AddrzXXX XXX representing the actual DMX address If the fixture is not receiving a DMX signal the display will flash If your fixture is connected to a DMX controller and the display is flashing not receiving a DMX signal please check the following he 3pin or 5pin XLR input plug cable with DMX signal from controller is not connected or is not inserted completely into the DMX input jack of the fixture The DMX controller is switched off or defective The DMX cable or connector is defective A DMX terminator has been inserted into the last fixture in your DMX chain 16 DW PROFILE User Manual 1 0 www elationlighting com FIXTURE MENU ON BOARD SYSTEM MENU The DW PROFILE comes w
17. g depends on the environment in which the fixture operates damp smoky or particularly dirty environments can cause greater accumulation of dirt on the fixture s optics Clean the external lens surface at least every 20 days with a soft cloth to avoid dirt debris accumulation e Never use alcohol solvents or ammonia based cleaners MAINTENANCE Regular inspections are recommended to insure proper function and extended life There are no user serviceable parts inside this fixture please refer all other service issues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A detailed electric check by an approved electrical engineer every three months to make sure the circuit contacts are in good condition and prevent overheating Be sure all screws and fasteners are securely tightened at all times Lose screws may fall out during normal operation resulting in damage or injury as larger parts could fall Check for any deformations on the housing color lenses rigging hardware and rigging points ceiling suspension trussing Deformations in the housing could allow for dust to enter into the fixture Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously injure a person s e Electric power supply cables must not show any damage material fatigue or
18. ith an easy to navigate system menu The next section will detail the functions of each command in the system menu LCD MENU CONTROL PANEL The control panel see image below located on the fixture allows you to access the main menu and make all necessary adjustments to the DW PROFILE During normal operation pressing MODE ESC button once will access the fixture s main menu Once in the main menu you can navigate through the different functions and access the sub menus with the UP and DOWN buttons Once you reach a field that requires adjusting press the ENTER button to activate that field and use the UP and DOWN buttons to adjust the field Pressing the ENTER button once more will confirm your setting You may exit the main menu at any time without making any adjustments by pressing the MODE ESC button CTadjust DW Profile 17 DW PROFILE User Manual 1 0 EtATION www elationlighting com ELATIONO DW PROFILE SYSTEM MENU specifications are subject to change without any prior written notice AXXX OOl Warm lave Slave2 Slaves FuncMode VB AutoProg otalHrs Timelnfo ast Hrs imePass 9 Templnfo HeadTemp V1 0 aster Alone emp C F Celsius Fahrenheit ResetDef ON OFF Cool Cool xxx Mancnrl 1 DiMo DiMo xxx Addr DMX stat Set NoDMXSta Off Time Persnal Disp Set I icc roPartl Program 1 10 Program 1 sel Prog roPart2 Program 1 10 Program 2 roPari3 Progr
19. matic Program Run Select FuncMode Press ENTER confirm Select AutoProg Press ENTER fo confirm Select Master or Alone Press ENTER confirm Press MODE ESC in order to return to the main menu 3 Program Selection for Automatic Program Run e Select EditProg Press ENTER confirm Select Sel Progm Press ENTER confirm Select ProPart 1 ProPart 2 or ProPart 3 and select which slave program is to be sent Selection Part 1 means the Slave unit runs the same program as the master units Press ENTER fo confirm Press MODE ESC in order to return to the main menu 4 Program Selection for Edit Program Select EditProg Press ENTER confirm e Select EditProg Press ENTER confirm Select the desired program to edit specific scenes into a specific program Press ENTER confirm Press MODE ESC in order to return to the main menu 2 DW PROFILE User Manual 1 0 EtATION www elationlighting com Que g g 5 Automatic Scene Recording e Select EditProg Press ENTER confirm e Select EditScen Select desired scene numbers A maximum of 250 scenes can be programmed Press ENTER confirm Press MODE ESC in order to return to the main menu Example Program 2 includes scenes 10 11 12 amp 13 Program 4 includes scenes 8 9 amp 10 Program 6 includes scenes 12 13
20. onnect the provided XLR cable to the female XLR output of your controller and the other side to the male XLR input of the DW PROFILE The diagram below illustrates a typical DMX 512 connection when the fixture is in the 8 Channel Mode You can chain multiple panels together through serial linking The cable that should be used is two conductor shielded DMX cable with XLR input and output connectors Always be sure daisy chain your in and out data connections never split or Y your DMX connections unless you are using an approved DMX splitter such as Elation s Opto Branch 4 Opto Branch 8 or DMX Branch 4 M ED DMX controller gan DMX512 Address 17 Address 9 Address 1 14 DW PROFILE User Manual 1 0 www elationlighting com DMX 512 CONNECTION WITH DMX TERMINATOR DMX terminator should be used in all DMX lines especially in longer runs The use of a terminator may avoid erratic behavior in your DMX line A terminator is a 120 ohm 1 4 watt resistor that is connected between pins 2 and 3 of a male XLR connector DATA and DATA This fixture is inserted in the female XLR connector of the last fixture in your daisy chain to terminate the line Using a line terminator will decrease the possibilities of erratic behavior Termination reduces signal errors and avoids signal transmission problems MI and interference It is always advisable to connect a terminal Resistance JI 120 Ohm 1 4 W betw
21. rder by which you can transmit the programmed scenes from your DMX controller to the moving head Adjust the desired scene numbers via the encoder from to When you call up the scenes at your controller they will automatically be transmitted to the moving head EditProg RecCntrl Working With Built In Programs A Master unit can send up to 3 different data groups to the Slave units i e Master unit can start 3 different Slave units which run 3 different programs The Master unit sends the 3 program parts in a continuous loop Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Auto Pro Part 1 Part 2 Part 3 Part 1 Part 2 Part 3 Part 1 Part 2 Part 3 The Slave unit receives data from the Master unit according to the group which the slave unit was assigned If e g Slave unit is set to Slavel in the menu SetSlave the Master unit sends ProPart 1 to the Slave unit If set to Slave2 the Slave unit receives ProPart 2 To start an Auto Program proceed as follows 20 DW PROFILE User Manual 1 0 EtATION www elationlighting com Que g g EditProg RecCntrl Working With Built In Program continued 1 Slave Setting Select FuncMode Press ENTER fo confirm e Select SetSlave Press ENTER confirm e Select Slavel Slave2 or Slave3 Press ENTER confirm Press MODE ESC in order to return to the main menu 2 Auto
22. risk of damage and or personal injury e Never look directly into the light source of this fixture to prevent risk of injury to your retina which may induce blindness Those suffering from EPILEPSY should avoid looking directly into the light source of this unit at all times The fan and air inlets must remain clean and never blocked Allow approx 6 15cm between this fixture and other devices or a wall for proper cooling e Always disconnect from main power source before performing any of service and or cleaning procedure Only handle the power cord by the plug end never pull out the plug by tugging the wire portion of the cord e Do not operate this fixture if the power cord has become frayed crimped and or damaged If the power cord is damaged replace it immediately with a new one of similar power rating 7 DW PROFILE User Manual 1 0 www elationlighting com GENERAL GUIDELINES NEVER OPEN THIS FIXTURE WHILE IN USE During the initial operation of this fixture a light smoke smell may emit from the interior of the fixture This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time This fixture is a professional lighting effect designed for INDOOR DRY LOCATIONS ONLY on stage in nightclubs theatres etc Please make sure there are NO FLAMMABLE MATERIALS close to the fixture while operating
23. secure a safety cable to a carrying handle 12 DW PROFILE User Manual 1 0 www elationlighting com UNDERSTANDING DMX DMX 512 DMX is short for Digital Multiplex This is a universal protocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers DMX allows all makes and models of different manufactures to be linked together and operate from a single controller This is possible as long as all the fixtures and the controller are DMX compliant A DMX controller sends the DMX data instructions to the fixture allowing the user to control the different aspects of an intelligent light DMX data is sent out as serial data that travels from fixture to fixture via data IN and data OUT XLR terminals located on the fixtures most controllers will only have output jacks DMX LINKING ensure proper DMX data transmission always use proper DMX cables and terminator When using several DMX fixtures try to use the shortest cable path possible Never split a DMX line with a Y style connector Ihe order in which the fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a starting DMX address of may be placed anywhere in the DMX chain at the beginning at the end or anywhere in the middle The DMX controller knows to send data assigned to adaress 1 to that fixture no matter where it is located in the DMX chain The DW
24. the only written warranty applicable to Elation Professional amp Products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published DW PROFILE User Manual 1 0 EtATION www elationlighting com e 9 9 SAFETY INSTRUCTIONS The DW PROFILE is extremely sophisticated piece of electronic equipment To guarantee a smooth operation it is important to follow the guidelines in this manual The manufacturer of this device will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual This device falls under PROTECTION CLASS 1 It s essential this device be grounded properly Only qualified personnel should perform all electrical connections CAUTION Never touch the device during operation The housing may heat up CAUTION Never look directly into the light source as sensitive persons may suffer an epileptic shock CAUTION Keep this device away from rain and moisture CAUTION Unplug mains lead before opening the housing e For proper operation follow the Installation guidelines described in this manual Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets included with this fixture should be used for installation Any modifications will void the original manufactures warranty and increase the
25. thorization R A number The R A number must be clearly written on the outside of the return package A brief description of the problem as well as the R A number must also be written down on a piece of paper and included in the shipping container If the unit is under warranty you must provide a copy of your proof of purchase invoice Items returned without a R A number clearly marked on the outside of the package wil be refused and returned at customer s expense You may obtain number by contacting customer support l gt IMPORTANT NOTICE There are no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will void your manufactures warranty Damages resulting from modifications to this fixture and or the disregard of safety and general user instructions found in this user manual void the manufactures warranty and are not subject to any warranty claims and or repairs 5 DW PROFILE User Manual 1 0 EtATION www elationlighting com Que g g 2 YEAR LIMITED WARRANTY A Elation Professional hereby warrants to the original purchaser Elation Professional products to be free of manufacturing defects in material and workmanship for a period of two years 730 days from the date of purchase This warranty shall be valid only if the product is purchased within the United States of America including possessions and territories It is the owner s responsibility to establish the date and pla