1. Mattress Characteristics Specification Max User Weight 275 lbs Q MEDQuUIP Mattress Dimensions 36 x 78 MQ9500 Materials PVC 0 3mm Alternating Pressure Pump amp Pad System MODEL APP B01 APP P01 USER S MANUAL Compressor pump Characteristics Cycle Time 6 Mins Air Output 6 7 L Min Pressure Range 0 130 mmHg Electrical Power Supply Volts 110V 60HZ Protection Against Class II Electric Shocks f Warranty One Year Distributed by MEDQUIP inc P O Box 1559 Bluffton SC 29910 CE OOS Made in China Operating Principles Alternating pressure at a sufficient rhythm avoids prolonged vascular compression which may cause tissue hypoxia Alternating pressure adapts the mattress to the patient and their position Guidelines For Use The traditionally accepted method of pressure sore control is to turn the client at regular intervals and to observe the areas of risk regularly Alternating pressure mattress is intended to compliment this treatment observation of the client and turning when necessary should still be considered as part of the treatment General For patients who are likely to spend more than 15 hours per day in bed For patients who are classed as medium to high risk of developing pressure ulcers Installation Use 1 Unroll the mattress 2 Position it on the bed 3 Secure mattress to the bed with the head and foot mattress flaps 4 Hang the
2. compressor pump at the end of the bed foot end using the hooks 5 Connect the mattress feed pipes to the compressor pump connector by matching the appropriate outlets 6 Connect the electrical power supply cable to the compressor pump 7 Guide it along the bed to the mattress plug socket and plug into outlet 8 Press switch to turn on the compressor pump 9 Before positioning the patient onto the mattress wait until the mattress has been fully inflated 10 Select the pressure corresponding to the patient s condition Safety Measures Close supervision is necessary when this product is used by on or near children or physically challenged individuals Use this product only for its intended use DO TAKE CARE when operating this electrical equipment DO NOT leave connected to electrical supply when not in use DO NOT expose the equipment to excessive humidity DO NOT use corrosive cleaning products such as industrial degreasers or acetic solvents DO NOT attempt to relocate this equipment whilst connected to the electrical supply Cleaning Disinfection Compressor Pump DO TAKE CARE to disconnect from the electrical supply before attempting to clean DO TAKE CARE to use a cloth impregnated with a mild detergent amp disinfectant following the product manufacturers directions Use a disinfectant cloth or detergent solution with a surface disinfectant to clean the unit Never immerse or soa
3. k the unit After cleaning insure the unit is completely dry from moisture before use Maintenance Periodically check the power cord and plug to insure there are no abrasions or excessive wear Plug in the pump and check the airflow from the hose connection port Airflow should alternate between the ports while cycling Compressor pump maintenance operations must be strictly carried out by an authorized trained technician
Download Pdf Manuals
Related Search
Related Contents
Metra Electronics NISSAN MURANO 99-7426 User's Manual Page 1 Page 2 旭川開村 ー 20年記念 ※コース開放日に来場される方 BECKER Repair and Service Manual VTLF, DTLF 取扱説明書 KW−H128 - 京セラコミュニケーションシステム Hotpoint BCI45 Dishwasher User Manual Community Edition dieser Ausgabe USER`S MANUAL Copyright © All rights reserved.
Failed to retrieve file