Home

HP StorageWorks Modular Smart Array 500 G2

image

Contents

1. adding redundancy to both the HBA in the host server as well as the SCSI cables connecting the host servers to the shared storage e Attach up to four independent servers to the Modular Smart Array 500 G2 The storage capacity to each server is assigned with SSP Shared Storage Presentation a feature of the Array Configuration Utility Using SSP and sharing storage among multiple host servers maximizes hard drive capacity utilization and allows for additional hard drive capacity to be deployed up to 14 with the volume extension and capacity expansion capabilities e Mix 2 node cluster and shared storage configurations This supported configuration allows for a 2 node cluster and 2 non clustered servers to share the Modular Smart Array 500 G2 storage systems for maximum storage utilization CA invent DA 11956 Worldwide Version 15 December 22 2006 Page 6 i Qu ickSpecs HP StorageWorks Modular Smart Array 500 G2 Modular Smart Array 500 G2 Components Smart Array Multipath Software Modular Smart Array 500 G2 Controller Management Features Controller Firmware Cloning Multi Host Storage Sharing O invent The Smart Array Multipath software included with the MSA500 G2 4 port I O Module or the High Availability Kit provides an additional level of fault tolerance by adding redundancy and performance to both the HBA in the host server as well as the SCSI cables connecting the host servers to the shared storage S
2. ADG drive rebuild rates Optional MSA 4 Port I O Module with Smart Array Multipath software Convertible to MSA 1000 for capacity expansion and increased host connections Remote configuration and monitoring via Array Configuration Utility amp System Insight Manager Qualitied and certitied for Windows Linux and NetWare clustering Support for ProLiant servers see Server Compatibility on page 14 or http www hp com go msa for latest compatibility O invent DA 11956 Worldwide Version 15 December 22 2006 Page 3 i Qu ickSpecs HP StorageWorks Modular Smart Array 500 G2 Product Highlights Modular Smart Array 500 G2 Highlights High Levels of Performance Data Protection and Functionality DtS DAS to SAN Technology O invent e High Availability supports a broad range of clustering options for Microsoft Windows Server Linux Server and Novell NetWare environments e High Performance 14 000 IO s in a 2 host 14 drive environment Double the workload performance of Ist generation MSA500 e Storage Capacity The Modular Smart Array 500 G2 cabinet supports up to fourteen 1 Universal hard drives for a maximum of 4 2TB of shared storage capacity using HP 300GB Ultra320 SCSI Universal 1 hard drives e Data Protection Modular Smart Array 500 G2 is designed for a high level of data protection It includes redundant controllers optional redundant fans and power supplies standard multiple I O p
3. Enterprise Server 8 UnitedLinux Conectiva Linux Enterprise Edition SCO Linux 4 0 SuSE Linux Enterprise 8 and TurboLinux 8 all powered by UnitedLinux 1 0 Not all configurations are supported on all operating systems please refer to compatibility matrix http www hp com products sharedstorage for latest compatibility information O invent DA 11956 Worldwide Version 15 December 22 2006 Page 9 J Qu ickSpecs HP StorageWorks Modular Smart Array 500 G2 Software Components Supported Clustering Solutions Microsoft Cluster Service for Microsoft Windows Server 2003 Enterprise Edition Microsoft Cluster Service for Microsoft Windows 2000 Advanced Server Novell Cluster Services on Novell NetWare 5 1 Novell Cluster Services on Novell NetWare 6 5 HP Serviceguard for Linux on Red Hat Enterprise Linux 2 1 Red Hat Enterprise Linux 3 0 UnitedLinux 1 0 SuSE Linux Enterprise Server 8 9 e SteelEye s LifeKeeper for Linux on Red Hat Enterprise Linux AS ES 2 1 Red Hat Enterprise Linux AS ES3 UnitedLinux 1 0 and SuSE Linux Enterprise Server 9 UnitedLinux Conectiva Linux Enterprise Edition SCO Linux 4 0 SuSE Linux Enterprise 8 and TurboLinux 8 all powered by UnitedLinux 1 0 Please refer to the HP High Availability Web site http h18000 www1 hp com solutions enterprise highavailability for latest information invent DA 11956 Worldwide Version 15 December 22 2006 Page
4. J Qu ickSpecs HP StorageWorks Modular Smart Array 500 G2 Overview 1 Display 5 Power Switch 2 Display Buttons 6 Status Indicators 3 Display Indicators 7 Redundant Controller Slot Blank 4 Modular Smart Array Controller 8 Drive Bay s 1 Power Supply Blower Indicators 4 SCSI Port B 2 Power Supply Blower Assemblies 5 SCSI O Indicators 3 SCSI Port A 6 SCSI I O with Integrated Environmental Monitoring Unit EMU ra DA 11956 Worldwide Version 15 December 22 2006 Page 1 J Qu ickSpecs HP StorageWorks Modular Smart Array 500 G2 Overview What s New End to end Ultra320 SCSI technology Support for 4 node clustering 256MB battery backed cache New Rapid Drive Rebuild technology increases RAID 5 and RAID ADG drive rebuilds At A Glance Total storage capacity of 4 2TB 14 HP Universal disk drives of 300 GB 4 node high availability clustering for Linux Lifekeeper and Serviceguard and NetWare 2 node high availability clustering for Windows Linux and NetWare Shared storage for up to 4 ProLiant servers Boot from storage move all disks to external storage for best capacity utilization Redundant capable Smart Array Controllers Multipath connectivity option with load balancing Redundant power supplies and fans standard Convertible to HP StorageWorks Modular Smart Array 1000 3 year warranty with next day on site service Protected by HP Services and a worldwide network of resellers and servi
5. Weight Gross 6 Ib 2 72 kg MSA500 G2 High Availability Kit option O invent DA 11956 Worldwide Version 15 December 22 2006 Page 17 QuickSpecs Technical Specifications HP StorageWorks Modular Smart Array 500 G2 Contents MSA500 G2 Controller 4 port Shared Storage I O Module 2 6ft SCSI Cables 2 SA 642 Adapters and Smart Array Multipath Software 2 0B Packaging Dimensions L x W x D 18x 12x 10 in 45 7 x 30 5 x 25 4 cm Weight Gross 8 Ib 3 6 kg Copyright 2006 Hewlett Packard Development Company L P The information contained herein is subject to change without notice Microsoft and Windows NT are US registered trademarks of Microsoft Corporation The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein For hard drives 1 GB 1 billion bytes Actual formatted capacity is less O TER DA 11956 Worldwide Version 15 December 22 2006 Page 18
6. 10 J Qu ickSpecs HP StorageWorks Modular Smart Array 500 G2 Services and Support HP Care Packs and Warranty Information Service and Support O invent Hardware diagnostic support and repair is available for three years from date of purchase Support for software and initial setup is available for 90 days from date of purchase Additional support may be covered under the warranty or available for an additional fee Enhancements to warranty services are available through HP Care Pack services or customized service agreements NOTE Limited warranty includes 3 year parts 3 years labor 3 years on site support Care Pack services provide a range of life cycle support options that let you choose the service levels that meet your business requirements from basic to mission critical A full range of HP Care Pack hardware and software services are available including e Installation and start up e Education courses e Extended onsite hardware coverage hours from same business day 13 hours 5 day to 24 hours 7 days call window with options including 4 hour response or 6 hour Call To Repair e Comprehensive range of software technical support for Microsoft Linux ProLiant Essentials and VMware based IT solutions helping to deliver high level of application availability Response times range from 30 mins for critical problems to 2 hours e System Management Performance Services and Mission Critical Support Solution Service includes
7. 2 Services and Support HP Care Packs and Warranty Information HP Care Pack 3 Yr 4h 13x5 U6455E Fixed Price Care Pack 3 Yr 4h 24x7 U6456E 3 Yr 6h CTR U6457E 1 Yr 4h 13x5 U8148E 1 Yr 4h 7x24 U8149E 1 Yr 6h CTR U8150E Hardware Installation U6458E HP Care Pack Support MSA500 1 Yr ND Hardware HA101A1 7GN Flexible Care Pack Support MSA500 3 Yr ND Hardware HA101A3 7GN Support MSA500 1 Yr 4h 13x5 Hardware HA103A1 7GN Support MSA500 3 Yr 4h 13x5 Hardware HA103A3 7GN Support MSA500 1 Yr 4h 2x7 Hardware HA104A1 7GN Support MSA500 3 Yr 4h 24x7 Hardware HA104A3 7GN Support MSA500 1 Yr 6h CTR Hardware HA105A1 7GN Support MSA500 3 Yr 6h CTR Hardware HA105A3 7GN Support MSA500 1 Yr Support Plus HA109A1 7GN Support MSA500 3 Yr Support Plus HA109A3 7GN Support MSA500 1 Yr Support Plus 24 HA110A1 7GN Support MSA500 3 Yr Support Plus 24 HA110A3 7GN Support MSA500 Installation HA113A1 564 O invent DA 11956 Worldwide Version 15 December 22 2006 Page 12 QuickSpecs HP StorageWorks Modular Smart Array 500 G2 Configuration Information Step 1 Order Required Items Models Package Contents HP Modular Smart Array 500 G2 includes 2 HBA Adapters Modular Smart Array 500 G2 Chassis Modular Smart Array 500 G2 Controller with 256MB cache 2 port Ultra320 SCSI I O Module Redundant Hot Pluggable Power Supply blower assemblies 2 HBA Smart Array 642 Adapters Modular Smart Arra
8. 4 Status Indicators on front of Controller 16 LVD Low Voltage Differential Wide Ultra320 SCSI 320 MB s per channel 4 total 2 Ultra320 SCSI channels supporting up to 4 host servers 2 Ultra320 SCSI channels supporting 14 disk drives 7 drives per channel 640 MB s maximum transfer rate Up to 14 drives 4 2 TB 14 drives x 300GB Up to 32 logical drives RAID ADG Advanced Data Guarding RAID 5 Distributed Data Guarding RAID 1 0 Striping amp Mirroring RAID 1 Mirroring RAID O Striping Standard 256 MB Read Write Cache Up to 512 MB Read Write with second 256MB cache module ECC protection battery backed and removable NOTE The Modular Smart Array Controller allows the following cache configurations 1 x256 MB 2 x 256 MB NOTE When redundant controllers are installed the cache configurations in both controllers must be identical Up to three days of redundant battery life removable for easy replacement 2 MB flashable ROM Ulltra320 Ultra3 and Ultra2 SCSI 1 inch Universal drives Dimensions L x W x D 14 5 x 11 5x 3 1 in 36 8 x 29 2 x 8 cm Weight Gross 6 Ib 2 72 kg MSA500 G2 Shared Storage I O Module option Connector Type Ports Bandwidth VHDCI Ultra320 SCSI 4 Ultra320 SCSI 320 MB s per port Protocols HBA Supported Ultra320 Smart Array 642 Smart Array 6i adapters Software Packaging Smart Array Multipath software 2 0B Dimensions L x W x D 14 5 x 11 5x 3 1 in 36 8 x 29 2 x 8 cm
9. HP branded hardware options qualitied for the storage enclosure purchased at the same time or afterwards internal to the enclosure These will be covered at the same service level and coverage period as the storage enclosure NOTE For more information on HP Care Pack services contact any of our worldwide sales offices or resellers or visit our worldwide Web site on the internet at http www hp com hps carepack NOTE For more complete information on HP Services offerings customers and resellers please visit us at http www hp com hps NOTE Additional information regarding worldwide limited warranty and technical support is available at http h1 8004 www1 hp com products servers plattorms warranty index html NOTE For additional information on Server Services Rack and Power Options please visit http h20219 www2 hp com services cache 111072 0 0 225 121 html NOTE The information contained herein is subject to change without notice and is provided as is without warranty of any kind NOTE The warranties for HP products and services are set forth in the express limited warranty statements accompanying such products and services NOTE Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein DA 11956 Worldwide Version 15 December 22 2006 Page 11 J Qu ickSpecs HP StorageWorks Modular Smart Array 500 G
10. ar Smart Array 500 G2 reducing expensive server downtime single path configuration only e Online Volume Extension allows for the capacity growth of existing logical volumes single path contiguration only e Logical Drive Capacity Extension allows the user to increase the size of existing logical drives online under Windows and offline for other operating systems e Online Stripe Size Migration allows changing stripe sizing of a logical drive e User selectable read write cache size allocate cache sizes e User selectable disk drive expand and rebuild priority with Rapid Drive Rebuild technology Enhanced Controller Firmware Auto Cloning allows customer choice of controller firmware version when adding redundant controller with different firmware version Easy to manage functionality through controller LCD panel at time of installation Selective Storage Presentation SSP support standard on both the base 2 port model of Modular Smart Array 500 G2 as well as the optional MSA 500 G2 4 port I O Module SSP allows the administrator to create volumes and assign access rights to a particular host server This allows sharing the Modular Smart Array 500 G2 with up to 4 host servers maximizing storage capacity utilization SSP also allows online capacity expansion as well as online volume extension in DAS configurations DA 11956 Worldwide Version 15 December 22 2006 Page 7 i Qu ickSpecs HP StorageWorks Modular Smart Array 500 G2 M
11. ath capability with Smart Array Multipath software option battery backed cache and RAID ADG standard e Storage Manageability The Smart Array Controllers feature familiar configuration and management tools such as HP Smart Array Configuration Utility and Insight Manager Online Management Features Online Capacity Expansion single path only Online RAID Level Migration Online Stripe Size Migration Online Spares Global User Selectable Read Write cache User Selectable Expand and Rebuild Priority e Choice of Computing Platform The Modular Smart Array 500 G2 is designed and qualified for ProLiant servers e Advanced Data Guarding RAID ADG Fault Tolerance This is the highest level of RAID fault tolerance It allocates two sets of parity data across drives and allows simultaneous write operations This level of fault tolerance can withstand two simultaneous drive failures without downtime or data loss The Smart Array architecture provides a quick and easy way to migrate from the Modular Smart Array 500 G2 to the Modular Storage Array 1000 MSA 1000 for additional scalability In order to convert the Modular Smart Array 500 G2 to a SAN simply remove the Modular Smart Array Controller s and replace them with StorageWorks MSA 1000 Conitroller s and add FC I O board or FC Switch please refer to MSA 1000 QuickSpecs for additional SAN requirements information This is referred to as DtS technology DAS to SAN technology In ad
12. cables two Ultra320 SCSI host adapters SA 642 two VHDCI SCSI cables and a crossover Ethernet cable for clustering Modular Smart Array 500 The Modular Smart Array 500 G2 Controller is an integrated RAID controller with an integrated G2 Controller LCD LED status display and 256 MB read write battery backed cache expandable to 512MB per controller One Modular Smart Array 500 G2 Controller is included with the Modular Smart Array 500 G2 the redundant Modular Smart Array 500 G2 Controller is an option Modular Smart Array 500 The Modular Smart Array 500 G2 HBA is a Smart Array 642 that offers two Ultra320 SCSI channels An G2 HBA external channel for connectivity to the MSA500 G2 systems and an internal channel to provide RAID protection to Disk internal to the ProLiant server The SA 642 is a 64 bit PCI X card backward compatible with 64 bit PCI slots MSA500 G2 4 Port I O The MSA500 G2 4 Port I O Module option offers 4 Ultra320 ports to extend connectivity to up to 4 Module with Smart Array hosts or supporting multipath configurations It frees captive storage capacity dedicated to a single Multipath server and increase storage utilization over internal server storage e 4 node cluster support with Serviceguard and LifeKeeper for Linux and Novell NetWare e Multipath support with load balancing enhances cluster fault tolerance by adding multiple paths trom the host servers to the MSA500 G2 This provides an additional level of fault tolerance by
13. cache memory protects data in the event of a power failure In the unlikely event of a controller failure the battery backed cache will save critical user data for up to three days Ultra320 SCSI I O e The I O module on the Modular Smart Array 500 G2 includes an integrated Environmental Module Monitoring Unit which performs several functions including monitoring the enclosure functions providing I O connectors and signaling enclosure status Modular Smart Array 500 G2 ships standard with a 2 Port I O Module The MSA500 G2 4 Port I O Module with Smart Array Multipath is available as an option e The 4 Port Shared Storage Module may be deployed as follows 4 node cluster with Linux LifeKeeper and Serviceguard and NetWare Multiple I O paths to a two attached servers 2 node cluster or shared storage and as the shared storage component with up to four servers in a configuration NOTE For additional information regarding ProLiant Server compatibility please refer to the following URL http www hp com go msa for latest compatibility O invent DA 11956 Worldwide Version 15 December 22 2006 Page 8 J Qu ickSpecs HP StorageWorks Modular Smart Array 500 G2 Software Components The Modular Smart Array 500 G2 utilizes a single consistent set of utility software for storage and RAID management setup configuration and troubleshooting This consistency reduces the cost of ownership by reducing the training and technical
14. ce providers Certain restrictions and exclusions apply Pre failure notification on processors memory and SCSI hard drives O invent DA 11956 Worldwide Version 15 December 22 2006 Page 2 J Qu ickSpecs HP StorageWorks Modular Smart Array 500 G2 Standard Features Modular Smart Array Family The HP StorageWorks Modular Smart Array family delivers simple affordable storage technology to meet today s demanding and growing IT needs These storage solutions offer the best price performance and best price availability features for direct attach environments small clusters workgroups and entry level SAN environments Each solution is designed to be easy to deploy secure reduce management costs while driving rapid return on investment Modular Smart Array 500 G2 High performance Modular Smart Array controller s with LCD for system status messages 256 MB Battery Backed Cache upgradeable to 512 MB maximum Optional redundant Modular Smart Array controller 4 2U rack mount chassis combining both the controller and disk shelf End to end Ultra320 SCSI Host interface back panel and drive interconnect Selective Storage Presentation SSP for storage sharing with multiple servers LUN Masking 4 2TB capacities with support of 14 Ultra320 Ultra3 and Ultra2 HP Universal Drives Redundant power supplies and fans are standard RAID levels O 1 1 0 5 RAID ADG Rapid Drive Rebuild technology accelerating RAID 5 and RAID
15. d for Linux A 11 16 for SUSE SLES 9 amp 10 and Red Hat EL 3 amp 4 single license version SteelEye LifeKeeper for Linux See http h18004 www1 hp com solutions enterprise highavailability linux index html NOTE Above options not required for Microsoft clustering Novell clustering or non clustered shared storage configurations Step 5 Choose Hard Drives Pluggable Universal U320 SCSI Hot Plug Hard Drives HP 72GB U320 10K Universal HDD HP 146GB U320 10K Universal HDD HP 300GB U320 10K Universal HDD HP 36GB U320 15K Universal HDD HP 72GB U320 15K Universal HDD HP 146GB U320 15K Universal HDD HP 300GB U320 15K Universal HDD NOTE All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds NOTE For complete compatibility information refer to the HP SCSI Hard Drive Compatibility table located at http www compaq com products hdd hotplug html Step 6 Choose Rack Option HP Rack 5000 Series HP 5642 RACK UNASSEMBLED Metallic Carbonite NOTE Please see the HP Rack 5642 QuickSpecs for additional part numbers and Technical Specifications such as height width depth weight and color http h1 8000 www hp com products quickspecs 12074 div 12074 div HTML Worldwide NOTE For additional information regarding Rack Cabinets please see the following URL www hp com go rackandpower Rack Options for Rack Stabilizer Kit for 5642 rack Graphite Carbon 5000 Series NOTE The s
16. dition to convertibility to the SAN the Modular Smart Array 500 G2 allows the seamless migration of stored data in ProLiant servers protected by Smart Array PCI controllers to a Modular Smart Array 500 system Data that is currently stored on 1 Universal disk drives using HP Smart Array controllers can easily be migrated to the Modular Smart Array 500 G2 Simply remove the drives from the older systems and insert them into the Modular Smart Array 500 G2 Existing data and configuration will remain intact In addition the RAID set and data will be preserved allowing migration to be completed in minutes not hours DA 11956 Worldwide Version 15 December 22 2006 Page 4 i Qu ickSpecs HP StorageWorks Modular Smart Array 500 G2 Product Highlights Low Total Cost of Ownership O invent The modular scalable design of the Modular Smart Array 500 provides an extremely flexible platform You can buy what you need today and purchase additional capacity and performance as your data storage needs grow instead of making a large up front investment Additional drives controllers and cache can be easily added as your needs dictate Storage Consolidation Improve storage utilization and lower storage management cost through moving internal storage to the Modular Smart Array 500 G2 Universal Hard Drive Since the Modular Smart Array 500 G2 supports HP Universal SCSI drives your investment in disk drives is protected and cost is m
17. eight width depth weight and color http h1 8000 www1 hp com products quickspecs 10995 div 10995 div HTML HP StorageWorks Modular Smart Array 500 G2 Pallet Shock Pallet Crated Shock Pallet Crated Worldwide NOTE For additional information regarding Rack Cabinets please see the following URL www hp com go rackandpower DtS Expansion Options SAN Conversion Options HP StorageWorks MSA1000 High Availability Upgrade Kit for Windows NOTE Includes 1 redundant controller 1 MSA SAN Switch 2 8 2 FCA2214 HBAs cables plus a ProLiant HA F200 kit with Secure Path for two servers Designed O invent as an upgrade for the MSA500 G2 HP StorageWorks MSA1000 High Availability Upgrade Kit for Linux NOTE Includes 1 redundant controller 1 MSA SAN Switch 2 8 2 FCA2214 HBAs cables plus Secure Path for Linux Workgroup Edition for two servers Designed as an upgrade for the MSA500 G2 Modular Smart Array 1000 Controller MSA Fibre Channel I O Module MSA SAN Switch 2 8 Integrated FCA2101 Host Adapter Microsoft 2Gb s SFP SW Transceiver Kit Modular Smart Array 30 Single Bus rack mountable NOTE The MSA 1000 controller and the MSA 1000 Fibre Channel I O module or the MSA SAN Switch 2 8 are required for conversion To obtain conversion procedure document go to http www hp com go msa500 and download Converting Modular Smart Array 500 to a Modular Smart Array 1000 for Additional Scalab
18. expertise necessary to install and maintain your HP server storage solution Configuration Utilities Array Configuration Utility ACU On line for Microsoft and Linux Remote Web Based amp Off line CPQONLIN for NetWare On line configuration Option ROM Configuration for Arrays ORCA Management System Insight Manager Health Utilities Array Configuration Utility Provides a graphical view of HP drive array configurations ACU e Easy to use Wizards for configuration e Web Based ACU supports On Line Remote Web Based and Off line configuration e Supports on line configuration for Microsoft and Linux e Configures Selective Storage Presentation SSP System Insight Manager e Powerful storage server and server option management tool e Monitor storage from a remote central location e Browser based Insight Manager 7 provides full access from anywhere on the Intranet eliminating the need for a dedicated Insight Manager console Microsoft Windows Server 2003 Web Edition Microsoft Windows Server 2003 Standard Edition Microsoft Windows Server 2003 Enterprise Edition Microsoft Windows 2000 Server Microsoft Windows 2000 Advanced Server Supported Operating e e J e e Novell NetWare 5 1 e e e e e Systems Novell NetWare 6 5 6 5 SBS Red Hat Enterprise Linux AS ES 2 1 3 Red Hat Enterprise Linux 3 0 SuSE Linux Enterprise Server 9 SLES9 UnitedLinux 1 0AS ES UnitedLinux 1 0 including SuSE Linux
19. ility document DA 11956 Worldwide Version 15 December 22 2006 379006 001 379005 001 292302 B22 257415 B2 257415 B22 245160 B21 2451 60 B23 245163 B21 245163 B22 245163 B23 353804 B21 353805 B2 218231 B22 218960 B21 288247 B2 245299 B2 221470 B21 302969 B21 Page 15 J Qu ickSpecs HP StorageWorks Modular Smart Array 500 G2 Technical Specifications Modular Smart Array 500 G2 LED Indicators on Front Power 3 Fault detected in one or more sub systems Fault in Enclosure Management LED Indicators for Drive Drive Access center Modules 3 Online lefi Drive Failure right LED Indicators on Rear Power Supply Blower Assembly Fault 1 Panel 4 EMU 3 Power A bus B bus Interface Ultra320 SCSI to Hard Drives Ultra320 SCSI to Host Servers Maximum Number of 14 1 in Ultra320 Ultra3 or Ultra2 Universal Hard Drives Modular Smart Array 500 G2 cabinet Drives Temperature Range Operating 50 to 95 F 10 to 35 C Shipping 2 to 122 F 0 to 50 C NOTE Rated 1 C per 1000 feet of elevation to 10000 ft Relative Humidity Operating 10 to 90 Non operating Up to 95 Input Power Requirements Rated Input Voltage 100 to 240 VAC Rated Input Frequency 50 to 60 Hz Rated Input Current 2 3 A at 120 VAC typical 6A Maximum Input Power max 549 W Heat Dissipation 1876 Btu hr maximum Input Power and Heat Dissipation specifications are maximum values and apply to worst case conditio
20. inimized as you add new drives Sharing of a common universal drive form factor between your server and storage can significantly reduce needs for hardware and spare inventory and offer overall reduction in storage management and business costs Pre Failure Warranty Drives installed in a Modular Smart Array 500 G2 and monitored under Insight Manager are supported by a Pre Failure replacement Warranty Pre Failure Warranty allows for the replacement of designated drives in Modular Smart Array 500 G2 before they actually fail when using Insight Manager on ProLiant servers NOTE Some operating systems may not support all of these features Integrated Configuration and Management Tools The Modular Smart Array 500 G2 utilizes the standard integrated set of Smart Array management and utility software These tools consistently lower the cost of ownership by reducing training and technical expertise necessary to install and maintain HP server storage DA 11956 Worldwide Version 15 December 22 2006 Page 5 i Qu ickSpecs HP StorageWorks Modular Smart Array 500 G2 Modular Smart Array 500 G2 Components Modular Smart Array 500 The 4U array houses up to fourteen 1 Universal hot pluggable Ultra320 Ultra3 and or Ultra2 drives G2 Enclosure Each Modular Smart Array 500 G2 includes the following standard components Modular Smart Array 500 G2 Controller 2 port Ultra320 SCSI I O Module dual hot pluggable fans power supplies two power
21. mart Array Multipath software delivers dual path functionality and supports failover capabilities for redundant host bus adapters HBAs When an HBA failure occurs the software moves the logical drives from the path of the failed HBA to the path of the redundant HBA located in the same server e Increase availability by protecting against connectivity HBA and cable failures and accidental pull outs e Increase performance with Static LUN Balancing Microsoft OS enables the administrator to optimize I O by assigning specific volumes to specific paths in the storage system If one path fails he system moves volumes to the path for redundant HBA for I O management e Increase performance with Static Load read only Balancing Linux OS enables the HBAs to optimize I O with dual paths to the same volumes in the storage system If one HBA fails the system moves volumes to the path for the redundant HBA for I O management e Supported Operating Systems Windows Server 2003 Standard Edition Windows Server 2003 Enterprise Edition Windows 2000 Server Windows 2000 Advanced Server Red Hat Enterprise Linux 2 1 Red Hat Linux Advanced Server 2 1 Red Hat Enterprise Linux 3 0 ES AS UnitedLinux 1 0 SuSE Linux Enterprise Server 8 9 e Online RAID Level Migration allows for online post configuration change to RAID level without destroying data or volume information e Online Capacity Expansion allows for adding storage to an operational Modul
22. ns at full rated power supply load The power heat dissipation for your installation will vary depending on the equipment configuration 2 Port SCSI I O Module Ports 2 VHDCI Ultra320 SCSI ports Dimensions 4 5 x 1 375 x 9 5 in 11 4 x 3 5 x 24 1 cm Weight 1 3 Ib 0 6 Kg Smart Array 642 Adapters Protocol Ultra320 SCSI SCSI Electrical Interface Low Voltage Differential LVD SCSI Port Connectors One external and one internal SCSI port Channel Transfer Rate 640 MB s total 320 MB s per channel PCI Bus Speed 64 bit 133 MHz PCI X 1 GB s maximum bandwidth PCI 3 3 volt CPI slot compatibility only Dimensions 12 3 x 4 2 x 0 6 in 31 24 x 10 7 x 1 5 cm H x Wx D Modular Smart Array 500 4U Rack Form Factor G2 Cabinet Dimensions HxWxD 6 9 x 19 x 20 5 in 17 5 x 48 3 x 52 1 cm Weight Net 50 Ib 22 5 kg Shipping Packaging Dimensions Lx Wx D 33 7 x 14 8 x 33 8 in 85 6 x 37 5 x 85 9 cm Weight Gross 70 to 105 b 31 5 kg O TE DA 11956 Worldwide Version 15 December 22 2006 Page 16 J Qu ickSpecs HP StorageWorks Modular Smart Array 500 G2 Technical Specifications Modular Smart Array 500 G2 Controller User Interface Electrical Interface Protocol Support SCSI Channels Drives Supported Maximum Capacity Logical Drives RAID Support Cache Memory Cache Batteries Upgradeable Firmware Disk Drive and Enclosure Protocol Support Packaging Controller Display with Status Indicators 2 and Push Buttons
23. odular Smart Array 500 G2 Components RAID Several fault tolerant configurations keep data available and servers running while drives are being replaced including e Advanced Data Guarding RAID ADG Allocates the equivalence of 2 parity drives across multiple drives and allows simultaneous write operations e Distributed Data Guarding RAID 5 Allocates parity data across multiple drives and allows simultaneous write operations e Drive Mirroring RAID 1 and 1 0 Striped Mirroring Allocates half of the drive array to data and the other half to mirrored data providing two copies of every file Modular Smart Array 500 Controller Cache e Cache on the Modular Smart Array 500 G2 Controller may be G2 Cache Upgrade and Upgrade upgraded to a maximum of 512 MB Fault Recovery NOTE The Modular Smart Array 500 G2Controller allows the following cache configurations 1 x 256 MB 2 x 256 MB NOTE When redundant controllers are installed the cache configurations in both controllers must be identical Fault Recovery e Rapid Drive Rebuild minimizes downtime reconstructs data and facilitates a quick recovery from drive failure e On Line Spares If a failure occurs recovery begins with an on line spare and data is reconstructed automatically One on line spare can be assigned per array and used across multiple arrays It is also possible to assign different on line spares across different arrays e Array Accelerator Onboard battery backed
24. tabilizer kit is used to prevent rack from tipping over Baying Kit for 5642 rack Graphite Carbon NOTE The baying kit is used to join two or more HP 5642 racks O invent DA 11956 Worldwide Version 15 December 22 2006 305199 B26 307754 B26 286714 B22 286716 B22 350964 B22 286776 B22 286778 B22 347708 B21 411089 B22 358254 B2 374493 B2 374499 B2 Page 14 QuickSpecs Configuration Information HP Rack 10000 Series Graphite Metallic Rack HP Infrastructure 42U LV Rack HP Infrastructure 42U HV HP 10614 14U Rack Cabinet Shock Pallet HP 10842 42U 800mm wide Rack Cabinet Pallet HP 10842 42U 800mm wide Rack Cabinet Shock Pallet NOTE Server Blade Enclosures must be field integrated into the 10842 racks Factory integration of Server Blade Enclosures into the 10842 is not supported HP 10647 47U Rack Cabinet HP 10647 47U Rack Cabinet HP 10636 36U Rack Cabinet HP 10622 22U Rack Cabinet HP 10622 22U Rack Cabinet NOTE xxxxxx B21 pallet used to ship empty racks shipped on a truck xxxxxx B22 shock pallet used to ship racks with equipment installed by custom systems VARs and Channels xxxxxx B23 crated used for air shipments of empty racks NOTE It is mandatory to use a shock pallet in order to ship racks with equipment installed NOTE Please see the Rack 10000 QuickSpecs for additional part number and Technical Specifications such as h
25. y 500 G2 Rack Mounting Kit Modular Smart Array 500 G2 Support Software or Smart Start Power cables 2 VHDCI SCSI cables 6 each 2 Crossover Ethernet cable for clustering User Manual Step 2 Choose Modular Smart Array 500 G2 System Options Options Modular Smart Array 500 G2 High Availability Kit includes MSA500 G2 controller MSA500 G2 4 port IO Module Smart Array Multipath Software and 2 SA 642 Adapters Modular Smart Array 500 G2 Controller MSA500G2 4 Port I O Module with Smart Array Multipath Software 256MB Battery Backed Cache Module M Series Rack Rail Kit Option Step 3 Choose ProLiant Server s Server Compatibility ML350 G3 G4 GS ML370 G3 G4 GS ML530 G2 ML570 G2 G3 G4 DL360 G3 G4 G5 DL380 G3 G4 G5 DL385 DL560 DL580 G2 G3 G4 DL585 G2 DL740 DL760 G2 For additional information regarding ProLiant Server compatibility please refer to the following URL http www hp com go msa for latest compatibility O invent DA 11956 Worldwide Version 15 December 22 2006 335880 B21 360229 B21 335881 B21 335882 B21 254786 B21 313877 B21 Page 13 i Qu ickSpecs HP StorageWorks Modular Smart Array 500 G2 Configuration Information Step 4 Choose Linux Clustering Configuration Options High Availability Software HP Serviceguard for Linux ProLiant Cluster A 11 16 for SUSE SLES 9 amp 10 and Red Hat EL 3 amp 4 2 node license cluster kit HP Serviceguar

Download Pdf Manuals

image

Related Search

Related Contents

NOVY 661 cooker hood  dreamGEAR ISOUND-1637  Smussatrici per tubi portatili  Bedienungsanleitung für Elektro-Unterbauherde mit  User Manual  SERVICE MANUAL - Wiki Karat  FUJITSU DL7600  MAGNA TYRES GROUP  Philips DVDR7250H User's Manual  Eglo SANIA  

Copyright © All rights reserved.
Failed to retrieve file