15 Manual - Cole
Contents
1. What is a Start Date Time If you are using this feature you will be able to set a date time to start a process or a program in the future Copyright 9 SalvisLab Edition 180311 11 Main Menu Overview General operation buttons In general you can scroll through the menu points with the button Select the desired menu point with lt 1 Temperature amp Options Manual Operation Define a set temperature and options like Gradient and Hold Time o Change Menu A Accept Menu gt 1 1 ESC returns to 1 2 Program Programmed Operation The menu Program is divided in menus for creating editing deleting starting and printing programs o Change Menu Accept Menu 2 1 ESC returns to gt 1 3 Configuration This menu point allows you to configure the system o Change Menu A Accept Menu gt 3 1 ESC returns to gt 1 4 Service Mode This menu point is protected by a access code and has limited access for the user o Change Menu A Accept Menu gt 4 1 ESC returns to gt 1 12 Copyright SalvisLab Edition 180311 1 Main Menu Temp amp Options Manual Operation Define a set temperature and options like Gradient Hold Time Dwell Time and Start date time A Accept menu D 1 1 ESC returns to 3 1 1 1 Set Temperature OO Change value TD E Accept value gt 1 2 ESC restores the old value or returns to 3 1 1 2 Select Quick Start or Start with Options O O Change ans
2. Less heat loss Saves energy and costs Robust Swiss quality design Made for scientific applications Work Chamber made of stainless steel and provided with wire shelf Exterior is of textured powder coated mild steel Applications The Incucenter is designed for all purposes of incubation in a variety of laboratory fields All Systems have a controller with alphanumeric display and programming capabilities Temperature range up to 80 C Note The Incucenter is not built to use as ovens for drying substances which are explosive or let free explosive gases during the drying process Construction Extremely compact construction Saves valuable space in the lab Inner chamber made of stainless steel For max 8 wire shelves Door seal can easily be removed for cleaning or replacing The door handle is integrated in the door No hot surfaces There is no risk of injury or burn Controller Fuzzy Logic Microprocessor controller with digital alohanumeric LCD Display and real time clock Wide range of temperature ramping functions More user application In combination with Fuzzy Logic gives you an excellent stability of temperature distribution and accuracy of programmed values Brilliant LCD Display for user dialog and easy to operate keypad for fast programming and operating User dialog with controller is displaying your local language Up to five languages can be selected Easy to operate and programming with EasyMenu It allows the
3. Offsets the internal PT100 sensor with the actual displayed temperature Calibrate with an external temperature sensor O O Change value A Accept value 3 3 11 ESC restores value 3 11 Confirmation of Storing Entered Values Confirmation that the Configuration has been Stored After a few seconds Display will return to Copyright 9 SalvisLab Edition 180311 21 4 Menu Service Mode 22 End user has only access to the History Data s Accept menu Change value to 8 Accept value Repeat until Display shows 888 Accept last value The number 11 indicates how many entries are stored Accept menu Display shows in the first line Date and Time when the entry was stored Second line shows the code for the Stored value message Change to next entry Change to next previous entry Back to Main Display History Change to next input field Change answer Accept answer After a few seconds Display will return to gt 1 Copyright 9 SalvisLab Edition 180311 Status Displays General Change the display with or set Display Interval to yes in Menu Configuration to let change the display automatically The display will differ according to the installed options 5 Status Display Manual Mode Defined Start Date If the programmed start date time has achieved the systems starts The display switches to 2 6 Start Date and Time O to next set of operating display Set T
4. Confirming amp Saving the new program Confirmation that the new program has been stored After a few seconds Display will return to 2 2 2 3 Menu Program Edit The example assumes to edit the program Z4 with 2 steps Edit an existing program Accept menu gt 2 3 1 ESC returns to 2 2 3 1 Choose program step to edit O O Change value Accept value and skips to the next field PS or 2 3 2 to the selected Step Number respective ESC returns to 3 2 3 Note Only stored programs steps will appear in the display Copyright 9 SalvisLab Edition 180311 17 2 3 2 Set Temperature Step 1 O Change value Accept value D 2 3 3 ESC restores the old value or returns to 2 3 and the step 1 as well as selected program number is not stored 2 3 3 Set Gradient Step 1 5 Change value dl Accept value D 2 3 4 ESC restores the old value or returns to 2 2 and the step as well as selected program number is not stored Note A value of 0 0 means maximal gradient 2 3 4 Set Hold Time Dwell Time Step 1 O Change value A Accept value and skips to the nekt input field HH MM or stores the time and go to gt 2 3 5 ESC restores the old value and skips back one input field or goes back to 2 3 and step 1 is not stored Note Value of 00 00 means endless holding time and program will not go to next step 2 3 5 Set Temperature Step 2 O O Change value Accept value 2
5. Exhaust Knob 9 31W04140003 Door Outer Case ICN52 10 31W04140001 Door Outer Case ICN118 11 31W04144017 Insulation for Exhaust 12 31W04144016 Closing Bolt 13 31W04960700 Door Switch 14 31W04140002 Door Inner Case ICN52 15 31W04140000 Door Inner Case ICN118 16 31W04144123 Temperature Probe PT100 17 31W04144002 Door Hinge 18 31W04962507 Over Temperature Fuse 19 31W04870018 Heating Element 230V 110W 20 31W04870019 Heating Element 230V 133W 21 31W04962923 Heating Element 115V 110W 22 31W04962924 Heating Element 115V 133W 23 31W0481 2003 Air Distribution Plate ICN52 24 31W0481 2020 Air Distribution Plate ICN118 25 31W04943203 Door Seal ICN52 1 5 Meter 26 31W04943203 Door Seal ICN118 2 0 Meter Copyright SalvisLab Edition 180311 31
6. Note Only stored program numbers will appear in the display 2 4 2 Deletion selection will be displayed O O Change answer A Accept answer If Yes selected D 2 4 3 If No selected D 2 4 2 4 3 Deletion confirmation will be displayed Confirmation that the selected program has been deleted After a few seconds Display will return to 2 4 2 5 Menu Program Print Print a program a Accept menu gt 2 5 1 ESC return to gt 2 2 5 1 Choose program to be printed O O Change value x Accept value 2 5 2 Ge ESC return to gt 2 Note Only used program numbers will appear in the display 2 5 2 Displaying print in progress Confirmation that the program has been printed After a few seconds Display will return to 2 5 Copyright 9 SalvisLab Edition 180311 19 3 Main Menu Configuration Configuration of the system by the user In this menu point you can define and set system options A Accept menu 3 1 3 1 Select language O O Change language Accept language 3 3 2 Attention After confirmation subsequent dialogs are displayed in the selected language 3 2 Set Actual Date for the Real Time Clock en U O Change value E Accept value and skips to the next input field Bl DDMM or saves the date and goes to 3 3 3 ESC restores the old value and or skips back one input field MM DD 3 3 Set Actual Time for the Real Time Clock O Change value A Accept value and
7. back to 2 2 and the step 1 as well as selected program number is not stored Note A value of 00 00 means endless holding time and program will not go to next step 2 2 5 Choose if a additional step is required 2 2 6 Set Temperature Step 2 16 O Change answer Accept answer If Yes selected step number will increment with 1 2 2 6 If No selected gt 2 2 1 O O Change value Accept value 2 2 7 ESC restores the old value or if in step 2 and higher returns to 9 2 2 5 but the actual step will not be saved Copyright 9 SalvisLab Edition 180311 2 2 7 Set Gradient Step 2 O O Change value Accept value D 2 2 8 ESC restores the old value or if in step 2 and higher returns to gt 2 2 6 but the actual step will not be saved O O Change value A Accept value and skips to the next input field HH3 MM or stores the time and go to D 2 2 9 ESC restores the old value and skips back one input field MM 3 HH or if in step 2 and higher returns to 2 2 7 but the actual step will not be saved Note A value of 00 00 means endless holding time and program will not go to next step 2 2 9 Choose if a additional step is required U 9 Change answer A Accept answer Hao If Yes selected step number will increment with 1 2 2 2 If No selected D 2 2 10 2 2 10 End of programming sequence DO Change answer A Accept answer If Yes selected D 2 2 11 If No selected gt 2 2 9 2 2 11
8. 180311 Operating How to interpret Displays Messages described in this Manual Power ON Sequence By pressing the power ON button the display will show the Software version All data s and stored information s are loaded during this process After a while display will show Main Menu Input Field A input value which is highlighted with yellow grey Background means this value is flashing on the real display Multiple Input Fields If you reach a multiple input display the first part of 3 in this example of the input field is flashing to indicate input here Flashing input fields are changed with or U Multiple Choice Fields In a multiple choice field the last actual saved value is flashing Change with or and confirm with Definitions of terms What is a Set Temperature A Set Temperature is the target temperature you want operate the oven with What is a Gradient A Gradient is the slope of the heating up process to the specific Set Temperature It is indicated as C Minute Negative Gradients are not allowed The maximal value of a gradient is system depending and has a range and is pre defined by the factory setup What is a Hold Time A timer is used to specify how long a set temperature has to be hold The timer starts counting back when 98 of the set temperature is reached The maximal time you can set is 999 hours and 59 minutes This is equal to 41 days 15 hours and 59 minutes
9. 3 6 ESC restores the old value or if in step 2 and higher returns to 2 3 but changes to the actual step will not be saved 2 3 6 Set Gradient Step 2 O Change value A Accept value D 2 3 7 ESC restores the old value or if in step 2 and higher returns to 2 3 but changes to the actual step will not be saved 2 3 7 Set Holding Time Step 2 O O Change value Accept value and skips to the next input field or stores the time and go to 2 3 8 MM HH or if in step 2 and higher returns to 2 3 but changes to the actual step will not be saved Note Value of 00 00 means endless holding time and program will proceed to next step 2 3 8 Choose if a additional step is required Change answer dl Accept answer He If Yes selected step number will increment with 1 2 3 2 If No selected gt 2 3 11 18 Copyright 9 SalvisLab Edition 180311 2 3 9 End of programming sequence O O Change answer i PUPCLIINP ani 2 A Accept answer Mee Lie If Yes selected gt 2 3 11 If No selected gt 2 3 9 2 3 10 Confirming amp Saving the new program Confirmation that the edited program has been stored After a few seconds Display will return to 9 2 3 2 4 Menu Program Delete Delete an existing program A Accept menu 93 2 4 1 ESC returns to 2 4 2 4 1 Choose program to be deleted O O Change value _ Accept value D 2 4 2 ESC returns to gt 2 4
10. IBED IN THIS MANUAL 11 MAIN e KEE 12 A MAIN MENU TEMP amp OPTIONS sinen itn entne alee ses aa e RENE EN Me da ER EH 13 2 MAN MENU PROGRAM EE 14 2 1 MENU PROGRAM START eene teen teen Wats een ae eenen Weede vie rea ua EE dee 15 2 2 REID da a 16 2 3 MENU PROGRAM 1 hase asus haee asses eas eaae nnn 17 2 4 MENU PROGRAM DELETE east rvan aen RN EY n RR CEDE TA AY VERE SR DE VA TX XR EE EY Da Vy a e WR EE 19 2 5 MENU PROGRAM Y va X Del Xx A Xa POR Y eo a edd 19 MAIN MENU 1 11 adesse nn 20 4 MENU SERVICE MODE 15 2 npepe ENEE i RID aa a a NG Sa 22 STATUS DISPLAY Saurare ege ed E e ek gege 23 deeg ge ee d e E DEEN DE 23 5 STATUS DISPLAY MANUAL MODE DEFINED START DATE 23 6 STATUS DISPLAY MANUAL MODE PROCESS RUNNING 23 7 STATUS DISPLAY PROGRAM MODE DEFINED PROGRAM START 24 8 STA
11. Incucenter ICN52 118 User Manual salvisiv r Copyright SalvisLab Edition 180311 User Manual Incucenter ICN52 118 DECLARATON OF CONFORMITY NENNEN ENNEN NENNEN ENNEN NENNEN 4 IMPORTANT 5 INFORMATION FOR SERVICE an D DE eda 5 TECHNICAL e NEE 6 INTRODUCTION codec dae nte nata one aer d aa ba el ec rea Sa ana a enia ice t a a Soa ne Era 7 OVERVIEW 7 ME elle 7 CONSTRUCTION Sii ven ENEE E eege gege g 7 et dee ee EE 7 SAFETY POWER CUT OFF is onse ooren gig EE EEN init nde dna Avonden viene 7 GETTING STARTED us 8 5 Se SE abies ee SN E 8 INSTALLATION REQUIREMENTS nnn 8 St Ce er ph SE A LUUD Ue EE EN 8 CLEANING VR EAR CER DC 8 SYSTEM COMPONENTS wid geg mere erwin KREIS Fea See de 9 CONTROLLER denn ene ONSE Nie Wedde Kee dE NN ENNEN EEN dE a a aaa 10 KEY PAD GU DISRLAY EE 10 OPERATING a ere E sated adsl tide Pine wad ennen an EE 11 HOW INTERPRET DISPLAYS MESSAGES DESCR
12. SalvisLab Edition 180311 Important Information Information for Service Please fill out all necessary information about your Vacucenter SERIAL NUMBER TYPE PHONE NUMBER SERVICE PURCHASE DATE SOFTWARE VERSION See Display during Power ON Copyright SalvisLab Edition 180311 Technical Data ICN 52 ICN 118 Outer Dimension Width mm 460 570 Height incl feet mm 525 650 Depth mm 590 720 Clearance distance from back wall mm 100 100 Clearance distance from side wall mm 100 100 Inner Dimension Width mm 340 450 Height mm 370 500 Depth mm 410 530 Internal Volume L 52 118 Wire shelf Standard max 2 8 2 8 Wire shelf dimension WxD mm 330x365 437x495 Distance between shelf mm 40 40 Max load per shelf kg 10 10 Max load per oven kg 40 40 Weight from oven empty kg 45 55 Temperature data Temperature Range approx gt 5 C oRt to ec 80 80 Temperature Variation at 37 C 0 5 0 5 at 50 C 0 7 0 8 Temperature fluctuation 2 at 37 C C 0 1 0 1 at 50 C C 0 1 0 2 Heating up time to 37 Min 25 41 to 50 Min 50 70 Recovering time after 30 sec door opening at 37 Min at 50 Min Electrical data Power supply 1096 50 60 Hz Volt 230 230 Nominal Wattage Watt 450 550 Energy consumption at 379C Watt 125 130 Housing protection EN 60529 IP20 IP20 Reco
13. TUS DISPLAY PROGRAM MODE PROGRAM RUNNING 24 9 CANCEL A RUNNING PROCESS BY ESC BUTTON 25 TO MESSAGES AND ERRORS areo Sana ga ENEE EEN ENEE EES 25 PRINTER OPERATION NEEN SEENEN Nu Bee NN EI ENEE haan de Suen eat A M wean 26 CONNECTING A PRINTER ENN e Dv Ee aa DEE 26 EXAMPLES FOR DIFFERENT 26 ge dn WEE a crc En a a a das a Da afa eR ai 27 WIRING DIAGRAM TEN EE 27 EE 28 DRAWING ed EET 28 APPENDIX ENEE EEN po arate vas neret alee ced pierre s di Ma 29 DRAWING IGN 2 29 2 Copyright 9 SalvisLab Edition 180311 APPENDIX D DRAWING SPARE PARTS APPENDIX E EEP SPARE PART NUMBERS Copyright 9 SalvisLab Edition 180311 CE DECLARATON CONFORMITY Wir We Renggli AG SalvisLab Nous Declaration of Conformity Name des Anbieters supplier s name nom du fournisseur Birkenstrasse 31 CH 6343 Rotkreuz Anschrift address adresse erkl ren in alleiniger Verantwortung dass das Produkt declare under our sole responsibility that the product d clarons sous notre seule responsabilit que le produit Incubator ICN 52 118 Year of Construction 2009 Bezeichnung Typ oder Modell Los Charge
14. eating element X9 Leer Empty A2 X11 Heizung Heating element X13 Display Display Elektroschema ICN 52 118 Wiring diagram ICN 52 118 020 De 1 _ UI D ee ix m E Ok J LI 57274 3 TM um z sut gp t3 Copyright SalvisLab Edition 180311 Appendix Drawing ICN52 28 Copyright SalvisLab Edition 180311 Appendix Drawing ICN118 07 TEE DEET KRISE 4 LUE Copyright 9 SalvisLab Edition 180311 29 Appendix D Drawing Spare Parts 19 20 21 22 30 Copyright SalvisLab Edition 180311 Appendix E Spare Part Numbers Position Part No Description 1 31W04141005 Panel New Version 2 31W04144155 Display Touch Panel 230V 3 31W04144154 Main PCB 230V 10 4 31W04144153 Main PCB 115V 10A 5 31W04142002 Air Inlet Protection Cover 6 31W04144014 Door Handle 7 31W04144013 Cable Relieve 8 31W04144018
15. emperature and Gradient O to next set of operating display Hold Time Dwell Time U returns to first set of operating display 6 Status Display Manual Mode Process Running Copyright 9 SalvisLab Edition 180311 Set Temperature and Actual Temperature O to next set of operating display Gradient and Hold Time O to next set of operating display Actual Date and Time O returns to first set of operating display 23 7 Status Display Program mode Defined Program Start Date If the programmed Start Date Time has achieved the system is running the selected program and the display switches to gt 8 Prog The LED Prog is flashing as long as the defined start date time has not been reached Start Date and Program number ESC Cancels the Start Date gt 9 8 Status Display Program mode Program Running The LED Prog is on during a programmed operation Prog Set Temperature and Actual Temperature O to next set of operating display Gradient O to next set of operating display Hold Time and actual Date and Time O to next set of operating display Program Number and Step Number U returns to first set of operating display If the program has finished a buzzer will sound and the following message will be shown Accept message 24 Copyright SalvisLab Edition 180311 9 Cancel a Running Process by ESC Button Pressing ESC stops a running heating cycle program 9 1 Safety questi
16. l Ring indicator Signal ground DE 9 pin assigment Protective ground Examples for Different Printouts Printout of a stored program To print the content of stored programs go to Menu Print Program gt 2 5 Program Nr 1 Step 1 Set Temperature 310 Gradient 0 0 C Min Hold time 1 00HH MM Printout during a manual program cycle In order to get printouts for logging you must set the print interval see Print Interval gt 3 5 to a value greater than 00 00 otherwise it is disabled Manual Operation Programmed Operation Date 01 01 10 Date 01 01 10 Time 12 00 Time 12 00 Set Temperature 370950 Program 4 Act Temperature Se Step 2 Gradient 0 0 C Min Set Temperature 37 0 C Act Temperature 30E Gradient 0 0 C Min Hold time 1 00HH MM 26 Copyright SalvisLab Edition 180311 Appendix Wiring Diagram ICN A Regelplatine PCB board A2 Display Platine Display board o 1 5 Heizung Heating element Fl Hauptsicherung Main fuse o F2 Uebertemp Sich Over temp fuse E F3 Uebertemp Sich Over temp fuse Sicherung Regelplatine PCB fuse 2 T rschalter Door switch Netzanschluss Main power clamp X2 Strom Regelplatine Main power PCB vooooooooooooed 5232 5232 RSR KA RS232 Ext RS232 Ext X5 PH100 PH100 X Leer Empty 7 T rendschalter Door switch X8 Heizung H
17. mmended ambient values oC 15 25 15 25 RhF96 20 60 20 60 Equipment Temperature Controller LCD Yes Yes Timer Hours Min 999 59 999 59 RS232 Interface Yes Yes Automatic Restart after Power Cut Off Yes Yes Adjustable Print Interval Yes Yes Programming Program Step 50 15 50 15 Ramp function Yes Yes 1 Measured with 3 temperature probes on horizontal level divided in 1 3 of the chamber size 2 maximum temperature deviation in time for one temperature probe 3 to 98 of set temperature All technical specification are specified for units with standard equipment at an ambient temperature of 25 C 77 F and a voltage fluctuation of 10 The temperature data are evaluated in accordance to following DIN 12880 part 2 respecting the recommended wall clearances of 10 of the height width and depth of the inner chamber All indications are average values typical for units produced in series Differing ambient temperatures or variances in the design of individual equipment may produce different performance We reserve the right to alter technical specifications at all times without prior notice Copyright SalvisLab Edition 180311 Introduction Overview The Incucenter ICN is a Incubator with natural convection and a Microprocessor Controller with enhanced Fuzzy Logic It allows precise ramping of temperature as well as an excellent reproduction of temperature distribution in the chamber Special Insulation
18. n oder Seriennummer m glichst Herkunft und St ckzahl name type or model lot batch or serial number possibly sources and numbers of items nom type ou mod le no de lot d chantillon ou de s rie ventuellement sources et nombre d exemplaires auf das sich diese Erkl rung bezieht mit der den folgenden Norm en oder normativen Dokument en bereinstimmt to which this declaration relates is in conformity with the following standard s or other normative document s auquel se r f re cette d claration est conforme a la aux norme s ou autre s document s normatif s Titel und oder Nummer sowie Ausgabedatum der Norm en oder der anderen normativen Dokumente title and or number and date of issue of the standard s or other normative document s titre et ou no et date de publication de la des norme s ou autre s document s normatif s Gem ss den Bestimmungen der Richtlinien following the provisions of Directives conform ment aux dispositions des Directives falls zutreffend if applicable le cas ch ant Safety EN 61010 1 2001 Safety EN 61010 2 2003 Low voltage directive 2006 95 EC EMC directive 2004 108 EC Ort und Datum der Ausstellung Name Unterschrift oder Kennzeichnung des Befugten Place and date of issue name and signature or equivalent marking of authorised person Lieu et date nom et signature du signataire autoris Rotkreuz 12 10 2009 Marcel K ppeli Technical Manager 4 Copyright 9
19. on when stopping a running system O O Change answer i PPCL et Se A Accept answer ri If Yes selected gt 9 2 If No selected Back to running status 9 2 Conformation of cancelling a process Confirmation that the running process has been stopped After a few seconds display will return to Main Menu gt 1 10 Messages and Errors The messages and Errors are announced by Buzzer and can be confirmed by pressing Messages Indicates that no program is in memory A Accept message Indicates that the program memory is full A Accept message Indicates that the door is open manual process or starting a program dl Accept message Errors 100 Sensor or cable defect A Accept message Call Service Temperature exceeded security range level A Accept message Cool down oven If error persist call Service dl Accept message Call Service Copyright SalvisLab Edition 180311 25 Printer Operation Connecting a Printer Printer Requirements In order to connect a printer with the serial RS232 Interface of the System following requirements must be fulfilled Serial RS232 Interface Min 4800 Baud Transfer Rate Pin Layout RS232 DB9 Connector System Data carrier detect Data set ready Used Pins 2 TxD 3 RxD and 5 Signal Ground Receive data Request to send Data format 8 Data Bits 1 Stop Bit No Parity er lear to sen ifi Data terminal ready No specific protoco
20. r goes back to 3 2 1 O O Change value Accept value and skips to the next input field HH MM If the Start Date Time is the past the display will return back to D 2 1 2 If your Start Date Time is in the future you will see the operating display 7 ESC restores the old value and skips back one input field MM 3 HH or goes back to 3 2 1 15 2 2 Menu Program New The storage capacity is Programs with 15 Steps Program Each Step contains Set Temperature Gradient and Hold Time The following sample assumes creating a Program 4 with 2 Steps 2 2 1 Create a new program 2 2 2 Set Temperature Step 1 2 2 3 Set Gradient Step 1 Create a new Program Accept menu gt 2 2 1 ESC returns to gt 2 OO Change value Accept value D 2 2 2 ESC returns to gt 2 2 Note Only free Program Numbers will appear in the display 5 Change value A Accept value 3 2 2 3 ESC restores the old value or returns to D 2 2 and the step 1 as well as selected program number is not stored OO Change value dl Accept value D 2 2 4 ESC restores the old value or returns to 2 2 and the step as well as selected program number is not stored Note A value of 0 0 means maximal heating power 2 2 4 Set holding time dwell time Step 1 U O Change value Accept value and skips to the next input field HH MM gt 2 2 5 ESC restores the old value and skips back one input field MM 3 HH or goes
21. s for creating editing deleting starting and printing programs O Scroll through the menu Accept menu gt 2 1 ESC returns to 1 Start a stored program O Scroll through the menu 1 Accept menu 2 1 1 ESC return to gt 2 Create a new program O Scroll through the menu Accept menu gt 2 2 1 ESC return to gt 2 Edit a stored existing program O Scroll through the menu Accept menu 2 3 1 ESC return to gt 2 Delete a stored program O Scroll through the menu Accept menu gt 2 4 1 ESC return to 2 Print a stored program O Scroll through the menu Accept menu gt 2 5 1 ESC return to 2 Copyright SalvisLab Edition 180311 2 1 Menu Program Start 2 1 1 Select Program 2 1 2 Choose type of program start 2 1 3 Set Start Date 2 1 4 Set Start Time Copyright 9 SalvisLab Edition 180311 Start an existing Program Accept menu gt 2 1 1 ESC returns to gt 2 O O Change value A Accept value D 2 1 2 ESC returns to 2 1 Note Only stored Program Numbers will appear in the display If no Program exist a message will be displayed O 9 Change answer Accept answer If Now selected Program starts immediately gt 6 If Later selected 2 1 3 ESC returns to gt 2 1 DO Change value A Accept value and skips to the next input field DD gt MM 3 YY or stores the date and go to gt 2 1 4 ESC restores the old value and skips back one input field o
22. se mild detergents No Acid or similar detergents should be used 8 Copyright 9 SalvisLab Edition 180311 System Components Air Exhaust Flap for Exhaust Air Inlet Door Handle Controller RS232 Interface Shelf Glider Wire Shelf Spring loaded door lock O Door Switch to indicate a open door alarm switch Copyright SalvisLab Edition 180311 Controller To control the system the controller has few easy to use buttons Simply turn press desired button All information are displayed on a Liquid Crystal Display LCD LED indicators for status of Power Heating and Program are used to indicate the main process status Buzzer is indicating audible Status or Alarm situation Keypad amp Display Buttons U Down Scroll through the menu structure U Plus Increase a value in flashing input fields select multiple choices Input value must flash to make button operable 5 Minus Decrease a flashing value select multiple choices Input value must flash to make O button operable Enter Confirm a menu selection a value input or an answer choice o 0 Escape Cancel actual operation goes back in Menu Structure quit actual state ON OFF Switch ON or OFF your System When ON LED is lit ED Indicators S al When lit Heat Power is on When lit You are running a program When flashing Delayed start for a program is entered 10 Copyright 9 SalvisLab Edition
23. skips to the nekt input field HH3 or saves the time and goes to gt 3 4 ESC restores the old value and or skips back one input field MM HH 3 4 Set allowed max Temperature Set the maximal possible temperature value for manual PL E operation Main Menu Temp amp Option Eua ER i UO Change value A Accept value 3 5 ESC restores value 3 5 Set Print interval for Printer Log via RS232 Interface Set the Print Interval time A value of 00 00 will disable printout of operating values O Change value A Accept value and skips to the nekt input field 55 and goes to 3 3 6 ESC restores the old value and or skips back one input field SS MM HH 3 6 Set automatic interval to scroll status displays Select if operation display will switch automatically instead of Pi manual switching by ae O Change value A Accept value D 3 7 20 Copyright SalvisLab Edition 180311 3 7 Select Baud Rate for RS232 Interface Available Baud Rate are 4800 9600 57600 115200 Accept value gt 3 8 3 8 Set Program End Buzzer Buzzer will give an audio signal when program has finished O O Change answer a Accept answer gt 3 9 3 9 Set Safety Alarm Buzzer In a case of an over temperature alarm situation the Buzzer will give an audio signal U 9 Change answer dl Accept answer 3 10 3 10 Set Offset between internal PT 100 Sensor and actual Display
24. storage of 50 programs with 15 program steps step 1 ramp 1 temperature and 1 Hold Time The programs remain stored in the memory even without external power Holding Time O 999h 59m The real time clock allows a process to be started at any time i e on December 6 2009 10 30 PM RS232 interface All data can be achieved with a printer or computer Door switch interrupts heating during open door Safety Power Cut Off DIN 12880 class 3 1 In case of over temperature a built in safety controller as a back up circuit takes over the control of the heating and will shutdown the oven There is also an additional mechanical over temperature device which shuts down the oven After a Power Cut Off the Controller restarts automatically and the last stored values will be maintained again only for Menu Temp amp Options High quality accurate PT 100 temperature sensor Superior Swiss Made manufacturing quality Copyright 9 SalvisLab Edition 180311 7 Getting Started Parts Delivered Your System will be delivered with following Parts 1 System Unit 2 Wire Shelf 1 Power Cord 1 User Manual Installation Requirements Electric power connection as per Serial Number plate on the inner door Installing Place shelf in appropriate position Plug cord Close door Switch power on Display shows current Software version during power on sequence To start oven see chapter Operating Menu Cleaning To clean the System u
25. wer A Accept answer If Now selected System will start immediately gt 6 If Option selected gt 1 3 ESC cancels and returns to gt 1 1 3 Set Gradient O O Change value A Accept value 3 1 4 ESC restores the old value or returns to 3 1 Note Value of 0 0 means maximum heating power up to set temperature 1 4 Set Holding Time dwell time U O Change value Accept value and skips to the next input field HH3 MM or stores the time and go to gt 1 5 ESC restores the old value and skips back one input field MM 3 HH or goes back to 3 1 Note Value of 00 00 means endless Holding Time 1 5 Set Start Date DO Change value A Accept value and skips to the next input field DDMMYY or stores the date and go gt 1 6 ESC restores the old value and skips back one input field YY9 MM 3 DD or goes back to 1 1 6 Set Start Time O O Change value A Accept value and skips to the next input field HH MM If Start Date Time is in the past you will see the operating display 6 If Start Date Time is in the future you will see the status display 5 ESC restores the old value and skips back one input field MMHH Copyright SalvisLab Edition 180311 13 2 Main Menu Program 2 1 Menu Program Start 2 2 Menu Program New 2 3 Menu Program Edit 2 4 Menu Program Delete 2 5 Menu Program Print 14 Program Operation The menu Program is divided in menu
Download Pdf Manuals
Related Search
Related Contents
ISO7000R Service Manual 取扱説明書 User Manual_Legion5500_V1.0.indd 取扱説明書 光BOX + START BOOK(PDF形式:18.8MB MANUAL DEL PROPIETARIO - Intex Development Company Limited Operational Procedures for the Thin Film Stress Instrument Hitachi ED-X45N data projector Union Switch & Signal - Ansaldo STS Copyright © All rights reserved.