1. To end the test press Ctrl C hold down Ctrl and press C TD3200 PT 2 Type H1ABCDEFGH and press ENTER key The display will show ABCDEFGH on the first line Type PASSTHRU and press ENTER key The data will be passed through to the peripheral e g a printer These characters are not shown on the display HINUMBER12345 then press ENTER key The display will show NUMBER12345 on the first line end the test press Ctrl C hold down Ctrl and press For further testing of OPOS displays TD3900 follow the instructions in the readme doc file after software installation INTERFACE CONNECTION Serial Interface Connector Configuration The pin out configuration for the standard serial table display is a DB9F connector It plugs directly into the serial port of the computer DCD tied to pins 4 amp 6 NC 5 1 RXD from PC ers 2 DTR tied to pins 1 amp 6 HE 7 Ground DSR tied to pins 1 amp 4 DB9F to computer RTS tied to pin 8 CTS tied to pin 7 NC a ot O NA For pass through models the display cable comes with two connectors The DB9F is to be connected to the computer while the DB25M is for connection to the peripheral DCD tied to pins 4 amp 6 7 TXD to PC RXD from PC PE 2 DTR tied to pins 1 amp 6 Ground DSR tied to pins 1 amp 4 DB9F to computer RTS tied to pin 8 CTS tied to pin 7 NC SNS OA N NC T
2. GENER i L 1 1 0 1D 1 1 10 N 1 1 1 1 RST GENERAL SPECIFICATIONS OPTICAL Number of rows Number of digits row Dot matrix Digit height Digit width Character config Brightness typical Display color MTBF hours MECHANICAL Weight Dimensions in inches Width Depth Height ELECTRICAL Adapter input power Adapter output power ENVIRONMENTAL Operating temperature Storage temperature Relative Humidity Vibration 10 to 55 Hz Shock CABLES amp CONNECTORS Standard Interface cable Pass thru Display cable Power adapter 2 20 5 x 7 plus underline 0 20in 5 0mm 0 14in 3 5mm ASCII 690 cd m Green Blue 300 000 1 4 Ib 7 9 3 2 120VAC 60Hz optional 220VAC 50Hz 6VAC 1000mA 0 to 50 C 20 to 70 C 80 non condensing 4G s 40G s RJ11 male to display DB9 female to computer DB9 female to computer DB25 male to peripheral Phone jack male Phone jack female 11
3. message of up to 45 characters PASS THRU COMMAND SET TD3100 PT All software commands of the non pass thru model are available with following additional commands for pass thru control When power is turned on or after a reset command has been initiated all text is displayed on the table display 1 Data to Peripheral lt 01 gt 01 lt gt All data following this command will be sent to the peripheral until a Data to Display command is received Data to Display lt 21 gt lt 23 gt lt 02 gt 33 35 02 B All data following this command will be sent to the table display until a Data to Peripheral command is received HARDWARE CONFIGURATION Serial table displays were factory configured for serial RS232C interface using the following protocol 9600 Baud Rate 8 Data Bits 1 Stop Bit No Parity Other optional baud rates are available with factory settings Refer to the model identification chart for further information DISPLAY CHARACTER CODES 10 0 0 0 Ne D6 0 1 NG ps 0 0 1 0 N D4 0 1 0 1 0 1 0 1 D3 D2 D1 DO 0 11 2 4 0 0 0 0 0 DP SP 17 00010 2 2 B 0 0 1 1 3 DL C 0 4 DIM 4 D 0 1 0 1 5 MS E 0 1 1 0 6 amp F 0101 117 i G 1 0 BS H 1 0 0 1 9 HT I 1 0 1 OJA J 1 K 1 1 0
4. Models TD3000 Series Table Displays 2 by 20 character display USER MANUAL LOGIC SS CONTROLS NOTICE The manufacturer of the POS table display makes no representations or warranties either expressed or implied by or with respect to anything in this manual and shall not be liable for any implied warranties of fitness for a particular purpose or for any indirect special or consequential damages Information in this document is subject to change without notice and does not represent a commitment on the part of the manufacturer FCC NOTICE This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this manual may cause interference to radio communications It has been tested and found to comply with the limits for a Class A digital device pursuant to Subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference LOGIC CONTROLS INC 355 Denton Avenue New Hyde Park NY 11040 TEL 516 248 0400 FAX 516 248 0443 Email lci logiccontrols com http www logiccontrols com TABLE OF CONTENTS FEATURES sm 1 MODEL IDENTIFICATION Aase 2 CARTON CONTENTS ie
5. XD to peripheral RXD from peripheral 1 13 RIS Tb CTS tied to pin 20 a 14 25 Ground NC DB25M to peripheral NC 20 DTR tied to pin 5 21 25 NC CNO OTER DA SOFTWARE COMMANDS Logic Controls table displays are controlled by command codes and data from the computer The model of pole display that you have will determine which command set works with your pole Refer to the model identification chart for further information Commands are transmitted to the table display as ASCII codes The command codes listed below are expressed in hexadecimal base 16 numbers enclosed inside angle brackets lt gt in decimal numbers enclosed in parenthesis and in ASCII characters enclosed in curly brackets Do not include the brackets as part of the command 4 character denotes Ctrl in the keyboard Press and hold Ctrl then press the next key LOGIC CONTROLS COMMAND SET TD3000 1 Vertical Scroll Mode lt 12 gt 18 R Data is written into the second row and transferred to the first row when carriage return is received leaving the second row empty 2 Normal Display Mode lt 11 gt 17 Q Data can be written into either row Moves to the left most digit of the other row when line is full 3 Brightness Control lt 04 gt 04 D The brightness of the display can be adjusted using this command followed by a data byte lt FF gt lt 60 gt lt 40 gt or l
6. able to the table display Connect the DBYF connector to the computer s serial COM1 or COM2 port Plug the power adapter into a 120VAC outlet A start up text message LOGIC CONTROLS POS COMPONENTS will be present for a short time When this message disappears the cursor will be displayed at the left most digit of the top row Pass thru Models Installation 1 5 6 The table display can be used in a freestanding mode or mounted to the counter with the two holes at the rear of the unit Connect the DB25M connector to the peripheral device or a serial pass thru terminator optional accessory Turn on power of the peripheral device Connect the female phone jack of the power adapter to the male phone jack of the table display cable Connect the DBYF connector to the computer s serial COM1 or COM2 port Plug the power adapter into a 120VAC outlet start up text message LOGIC CONTROLS POS COMPONENTS will be present for a short time When this message disappears the cursor will be displayed at the left most digit of the top row FUNCTIONAL TEST The following test sequence will verify that your table display is working properly Before you start this procedure you must install the table display correctly as outlined under the INSTALLATION section The functional test should be done under MSDOS command prompt by booting up the computer in DOS mode or shell out to DOS prompt in window95 98 ME or COMMAND prompt in wind
7. en noes 2 INSTALEA HON pansrede at e Dd hgh 3 FUNCTIONAL TEST 2 2 4 INTERFACE 6 SOFTWARE COMMANDS 7 HARDWARE 9 DISPLAY CHARACTER 10 GENERAL SPEGIFIGATIONS 11 iii FEATURES The TD3000 family of table displays offers a wide range of high quality features and models to choice from Listed below are the features incorporated into each table display Not all features are available in all models The model identification chart will assist you in selecting the model best suited to your needs The TD3000 family has the industry standard 5mm high vacuum fluorescent 5x7 pixel display Features All Models e Bright green fluorescent display Supports high speed serial protocol up to 19 200 baud rate 1 stop bit Automatic message scrolling Two line display with 20 characters per line Matched optical lens for better viewing contrast Ergonomic design Direct RS232C interface Long life and trouble free operation Simple installation Available with 120V or 220V Power Adapters Features Model dependent Emulation of other popular command sets User definable character True RS232C pass thru Real time clock One time message scrolling Ability to disable attenti
8. on code Ability to change attention code MODEL IDENTIFICATION 5 EE IE Blank No Pass Thru PT Pass Thru 25 DB25F connector to computer POWER ADAPTER 120VAC COMMAND SET 1 220 0 LOGIC CONTROLS 1 LOGIC CONTROLS SERIAL PARALLEL INTERFACE WITH PASS THRU 0 SERIAL 9600 BAUD 2 SPECIAL COMMAND SET 1 Aedex emulation 1 SERIAL 600 BAUD 3 SEPCIAL COMMAND SET 2 Noritaki emulation 2 SERIAL 1200 BAUD 4 SPECIAL COMMAND SET 3 Epson D202 emulation 3 SERIAL 2400 BAUD 5 SPECIAL COMMAND SET 4 Ultimate PD1100XL XLT 4 SERIAL 4800 BAUD 9 OPOS COMMAND SET 5 SERIAL 19200 BAUD Default Values Call for description of Command Sets CARTON CONTENTS Table display pre assembled 2 Interface cable comes with DB9F connector to computer an RJ11 connector to table display as standard equipment Optional DB25F connector to computer is available Note This cable is only supplied with standard serial table displays with no pass thru function 3 Transformer adapter 120VAC to 6 0VAC optional 220VAC 4 Quick Installation Guide INSTALLATION Your TD3000 family of table displays has been pre assembled to make the installation as simple as possible Standard Models Installation 1 2 3 4 5 The table display can be used in a freestanding mode or mounted to the counter with the two holes at the rear of the unit Connect the RJ11 connector of the interface c
9. ows NT 2000 NOTE The actual key entries in the text below are enclosed within quotation marks Do not type the quotation marks as part of your entries This test procedure assumes the pole display is connected to COM1 of the computer If COM2 is being used type COM2 where COM1 is called out Close all opened application programs that use the same COM port before going into DOS command prompt Enter the following command lines to open the COM port for communication with the table display Type MODE COM1 96 N 8 1 and press the ENTER key Type TYPE gt and press the ENTER key TD3000 TD3300 TPD3400 TD3500 and TD3900 1 Type ABCDEFGH and press ENTER key The display will show on the first line 2 To end the test press Ctrl C hold down Ctrl and press TD3200 1 Type HT1ABCDEFGH and press ENTER key The display will show ABCDEFGH the first line 2 To end the test press Ctrl C hold down Ctrl and press C TD3100 PT TD3300 PT TD3400 PT and TD3500 PT 1 2 Type ABCDEFGH and press ENTER key The display will show ABCDEFGH on the first line Type APASSTHRU represents and press ENTER key The data will be passed through to the peripheral e g a printer These characters are not shown on the display Type H BNUMBER12345 then press ENTER key The display will show NUMBER12345 on the first line
10. t 20 gt 4 Back Space lt 08 gt 08 H The cursor position moves one digit to the left erasing the previous information 5 Horizontal Tab lt 09 gt 09 1 The cursor position shifts one digit to the right without erasing character at original cursor position 6 Line Feed lt 0 gt 10 J The cursor position moves to the same position in the other row In vertical scroll mode if cursor was in second row the cursor will not move and display will scroll up 7 Carriage Return lt 0D gt 13 M The cursor moves to the left most digit of the row it is in 7 10 11 12 13 Digit Select lt 10 gt 16 P Moves the cursor to any position on the display with this command followed by a data byte of lt 00 gt to lt 27 gt or in decimal 00 to 39 Cursor On lt 13 gt 19 S Turns on the cursor Cursor Off lt 14 gt 20 T Turns off the cursor Reset lt 1F gt 31 All characters are erased and all settings are returned to the power on reset conditions Down Load Font lt 03 gt lt X gt lt F gt lt F gt lt F gt lt F gt lt F gt Assign a keyboard key ASCII code lt 20 gt to lt 7F gt to a different style font The X represents the ASCII code for the selected key The F s represent the 5 segments that will make up the special font Message Scroll lt 05 gt lt X gt lt X gt lt X gt lt X gt lt 0D gt Scrolls a continuous
Download Pdf Manuals
Related Search
Related Contents
Miller Electric DVI-2 R User's Manual Sandberg Touch Screen Gloves White Dolphin™ Handheld Computer and HomeBase™ User's Guide PRODUCT AND TECHNICAL CATALOGUE Orifice Fittings and Equipment User Manual AMC 277 - Ministerio de Comercio Exterior y Turismo Microlevelling (T33) - Intrepid Geophysics safety precautions JVC Projector DLA-VS2000U User's Manual アフェレシス装置・器材の安全基準についての提案 Ver.1.1 Copyright © All rights reserved.