Home
AW-RP50 Simple Manual
Contents
1. 8 CAMERA Power All Off 2 POWER mpm Select POWER by F1 dcus rn v Press F1 ALL OFF Power All On Select ALL ON by F2 emi ap Press F2 ALL OW Basic Operation 1 How to adjust a camera 1 Press MENU button and select a function 2 How to control Pan Tilt Iris and Zoom 1 Press PC ACTIVE button Adjust PTZ SPEED dial and use PAN TILT lever ZOOM lever FOCUS dial and IRIS dial Y gt 6 O mS Y j L J 409 IRIS AUTO CAMERA STATUS SELECTION PT ACTIVE 7 y DOTEE 3 How to preset a camera position tt 1 Select a camera CAMERA STATUS O SELECTION move to the specific position press STORE button press PAGE button and hold down Number button STORE DELETE Advanced Operation 1 Camera Detailed Setting by OSD 1 Hold down the CAMERA OSD 2 Use F1 F2 to select an item 3 Top Menu 1 Camera Scene 2 System 3 Mlaintenance y MENU Camera Adjustment Press Menu f PAGE button lights on you switch ON Press number button of PRESET MEMORY MENU area 1 GAIN PED 2 R B GAIN 3 R B PED 4 AWB ABB 5 SHUTTE 6 DETAIL 7 SCENE MODE 8 CAMERA 9 SETUP 10 SYSTEM Turn F1 F2 to change mode or adjust Some settings AWB ABB MODE and so on require to execute At that time press F1 or F2 to execute Control Pan Tilt Hold down
2. 5 the data of the preset number 25 is deleted Setting the USER buttons meno tem Daas of operation performed __ On Enable B Registering functions in the SWLIMK This sets the link control between the unit and switcher Off Disable FASIST This is the bus switching setting This sets the focus assist function This displays icons at the bottom left of the images from the remote camera selected by the unit on the multi view display of the switcher This sends the tally information sent periodically by UDP from the switcher to the remote camera On Enable Off Disable On Enable Off Disable On Display Off Non display This sends the camera information of the remote camera selected to the switcher AWE is executed when the USER button in which AWB has been assigned is pressed When AWB is executed successfully the indicator of the button goes off conversely when it is not executed successfully it blinks ABB is executed when the USER button in which ABB has been assigned is pressed When ABB is executed successfully the indicator of the button goes off conversely when it is not executed successfully it blinks When the USER button in which POWER OFF has been assigned is held down the indicator of the button lights for an instant and power OFF is requested for all the remote cameras connected On Enable Off Disable USER buttons Set the MENU button to ON Press the MENU butto
3. AW RP50 Simple Manual Getting started Camera control has 2 kinds of protocol Serial RS422 IP Ethernet Both cables are CAT5 But CAT5 has 2 kinds of interconnections RS422 Serial Cross Cable because direct connection P Ethernet Straight Cable because it is connected to HUB Don t forget menu setting of RP5O SYSTEM CAMERA CTL CAM1 to CAM 100 e Select Serial or Network 1 CAMI v 2 CAM2 m Serial Network E Note for Serial Connection Connection with the AW HE50 AW HE50 Remote camera control signal AW RP50 LAN cable j ca Su RJ 45 relay adapter Monitor 1 Use straigh cables ca erf 5 or above for these connections 2 The muljfinterface cable AW CA20T6G is required for the serial Zonnection with the AW HE50 HE50 CAT5 cable must be cross type And You need Multi Interface Cable AW CA20T6G and RJ 45 relay adapter Connection with the AW HE100 120 LAT ERAS Remote camera control signal AW RP50 LAN cable cE HRACTITS Use straight cables category 5 or above for these connections HE120 CAT5 cable only There is no need to use special cable Auto Setup of IP Address IP Address Auto Setting f you cannot connect to a camera try to do auto setup MENU SYSTEM AUTO SET IP AUTO SET UP RENEW IP ADR and pres
4. Down CONV Mode Squeeze SideCut LetterBox HDMI Color Other Next Page Other 1 2 Other 2 2 Other HE50 e Other Install Position Desktop Hanging Preset Speed 1730 Preset Scope Mode A Mode B Mode C Digital Zoom Enable Disable Speed With Zoom POS Focus Mode Manual Auto Focus ADJ With PTZ Off On Return e Other 2 2 Tally Enable Enable Disable OSD Off With Tally Off On OSD Status Off On Wireless Control Enable Disable What is SCOPE B Setting the operations to be performed when a preset operation is executed The operations which the remote camera is to performed when the preset operation is conducted can be set From the SETUP menu select PRESET and display SCOPE Then set the operations to be performed 2 5602 MODE Al The operations that the camera performs when a preset operation is executed differ depending on the mode selected Or f ita 148 De Pan tilt zoom focus Iris gam white balance Pan tilt zoom focus iris Pan tilt zoom focus Note This function takes effect when the unit is connected to the AW HESO It does not work with any other models 3
5. destal Return Matrix Matrix Type Normal EBU NTSC User Linear Matrix Color Correction Color Correction 2 2 Scene Matrix e Matrix Type Normal EBU NTSC User Linear Matrix Saturation Phase R B G R B R B G Color Correction 1 2 Saturation Phase B Mg MgR R Color Correction 2 2 Saturation Phase G G Cy Cy Cy_B B System HE120 e Genlock Horizontal Phase 2067 49 Horizontal Phase 6 0 e Output Format 1080 59 94i 720 59 94p 1080 29 97PsF Down CONV Mode Squeeze SideCut LetterBox HDMI Color RGB NOR RGB ENH YCbCr422 YCbCr444 Component Y Pb Pr RGB Frequency 59 94Hz 50Hz Color Bars Setup Off On e Other Next Page Other 1 3 Other 2 3 Other 3 3 Other HE120 e Other 1 3 Install Position Desktop Hanging Smart Picture Flip Off Auto e Flip Detect Angle 607120 Preset Speed 1730 Preset Scope Mode A Mode B Mode C Digital Zoom Enable Disable Speed With Zoom POS Return e Other 2 3 Focus Mode Auto Manual e Focus ADJ With PTZ On Off Digital Zoom Enable Disable e Max Digital Zoom x2 x10 Tally Enable Enable Disable Wireless Control Enable Disable Return Other 3 3 OSD Mix e SDI Out On Off e HDMI Out On Off e Component Out On Off e Video Out On Off OSD Off With Tally On Off OSD Status On O
6. e setting that is displayed differs between the AW HESO and other remote cameras Display that appears with the AW HE50 The current setting status is displayed in the LIMIT DOWN item f 3 LIMIT DOWN OFF Turn the F2 dial and then press J L it 3 LIMIT DOWN Onl Setting the right limit From tha SETUP menu select PTZ ADJ and display LIMIT RIGHT Then set the right limit The setting that is displayed differs between the AW HE50 and other remote camaras Display that appears with the AW HE50 The currant setting status is displayed in the LIMIT RIGHT item B LIMIT RIGHT 4 Df f Turn the F2 dial and then press J E 5 LIMIT RIGHT Onl Note Move the camera to the position where you want to limit at first Limit position becomes the position where you turn on Appendix Camera OSD CAMERA OSD HE120 1 Hold down the CAMERA OSD 2 Use F1 F2 to select an item 3 Top Menu Camera Scene Scene1 4 Scene Brightness Picture Matrix System Genlock Output Other Maintenance Firmware Version IP Network Initialize 4 Press Return to return to upper menu Camera Scene HE120 Scene Scenel 4 Brightness Picture Level Iris Mode Shutter Mode Step Synchro Gain AGC Max Gain Frame Mix ND Filter Return Picture Chroma Level 3 3 White Balance Mode AWB A AWB B 3200K 5600K R Gain 150 150 BGain 150 4150 Pedestal R Pedestal 8 Pe
7. ff Return CAMERA OSD HESO 1 Hold down the CAMERA OSD 2 Use F1 F2 to select an item 3 Top Menu Camera Scene FullAuto Manual1 3 Scene Contrast Picture Color Matrix System Genlock Output Other Maintenance Firmware Version IP Network Initialize 4 Press Return to return to upper menu Camera Scene HE50 Scene FullAuto 3 Contrast Contrast Mode Contrast Level 5 45 Shutter Mode Step Synchro Frame Mix AutoF Mix Max Gain 0 6 12 18dB Gain Auto 0dB 3dB 6dB 9dB 12dB 15dB 18dB AGC Max Gain 6dB 12dB 18dB Return Picture Chroma Level 3 3 AWB Mode AWB A AWB B ATW Detail Off Low High Flesh Tone Mode Off Low High DNR Off Low High DRS Off Low High Gamma Type Normal Cinema Off Gamma Level Low Mid High Normal Back Light Comp Off Onj Return Matrix Matrix Select Normal EBU NTSC USER Scene Matrix You can change at USER Matrix Select Normal EBU NTSC User 1 3 Saturation 01 Axis02 AxisO3 Axis04 Axis05 Axis06 Phase Saturation Phase 07 AxisO8 AxisO9 Axis10 Axis11 Axis12 Saturation Phase Axis13 Axis14 Axis15 Axis16 System HE50 e Genlock Horizontal Phase 2067 49 Subcarrier Phase e Coarse 0 45 90 135 180225 270 315 e Fine 12 127 H Phase SC Fine Step 1 10 e Output Format 1080 59 94i 720 59 94p 1080 29 97PsF
8. n to light its indicator Set the PRESET MEMORY MENU 9 button SETUP to ON When the button is pressed and its indicator lights the SETUP menu is displayed on the LCD panel pue T Press the F1 dlal Turn the F1 dlal to display USER1 or USER2 1 051 Y SWLINK Ad Turn the F2 dial to select the Item to be assigned and press the F2 dial 1 USER1 v SWLINK Turn the F2 dial and then press J it 1 USER1 BUSCONTI The Movement Range of the Remote Camera Limiter Function Setting the upper limit From the SETUP menu select PTZ ADJ and display LIMIT UP Then set the upper limit The setting that is displayed differs between the AW HE50 and other remote cameras Display that appears with the AW HE50 The current setting status is displayed in the LIMIT UP item 2 LIMIT UP Off Tum the F2 dial and then press e d Z LIMIT UP On e Setting the left limit From tha SETUP menu select PTZ ADJ and display LIMIT LEFT Then set the laft limit The setting that is displayed differs between the AW HEB50 and other remote cameras Display that appears with the AW HE50 The current setting status is displayed in the LIMIT LEFT item 4 LIMIT LEFT Off Tum the F2 dial and then press it A LIMIT LEFT Onl Setting the lower limit From the SETUP menu select FTZ ADJ and display LIMIT DOWN Then set the lower limit Th
9. s the F2 dial 1 AUTO SETUP RENEM IP ADRI Turn the F2 to select YES and press the F2 dial C 003 003 5 1 1 ES 1 Manual Setup of IP Address IP Address Manual Setting MENU SYSTEM NETWORK temem Press F1 dial and turn F1 Select IP ADDRESS and Press the F2 dial Turn F2 dial Tibe PP Select IP address and press F2 Dial Factory Setting e Initialize MENU SYSTEM INITIALIZE 11 INITIALIZE Press the F1 dial Turn F2 dial and select ALL or SETUP and press F2 ALL The settings controlled by the unit are returned to the factory statuses SETUP Only the settings on the menus below are returned to the factory statuses CAMERA menu _ 2PowEeER lmay 2 SW LINK 3 SW DISP 4JOPERATE 5 PRESET ul a _ aswo sP IMIOPERATE iSIPRESET jg _ ekcoB tMENUCTL 10 MENU CTL Outlook JU 2 12 x 4 5 I Remote Camera Controller AV RPSO one CAMERA DAD G EEC ij _ ket USERT1 USER E jog OT CAMERA S TATUS SELECTION e PJ Power ON OFF of cameras Power ON OFF one camera 1 Select the camera Hold down the number button 2 Turn the F2 dial to select ON and Press the F2 dial Note Hold down the number button during setting Power ON OFF all cameras Menu
10. the PT ACTIVE Select a Camera SELECTION Adjust IRIS e Auto button lightson Auto iris e Auto button lights off ManualWris ZOOM lever Adjust FOCUS e Auto button lights on Auto focusing e Auto button lights off Manual focusing One touch autofocus Press focusing dial and autofocusing works Adjust PTZ SPEED dial e Clockwise Speed increases Counter clockwiseySpeed decreases Make a camera move by PAN TILT lever PRESET Camera Position Store How to store the camera position 1 Select a camera 1 5 Adjust the camera position Press the STORE button Press the PAGE button and then press the number button 1 Thisis page number 5 Hold down the number button 1 Thisis number of the page 2 Ifyou press 2 and 5 preset number becomes 25 p ow i PRESET Camera Position Recall Executing the preset data 1 Select a camera 1 5 2 Press the PAGE button and then press number button 1 Thisis page number 3 Press the number button 1 Thisis number of the page 4 The camera moves to the preset number position 1 Ifyou press 2 and 5 the camera moves to the preset number 25 Delete PRESET Camera Position Deleting the preset data 1 Select a camera 1 5 2 Press the DELETE 3 Press the PAGE button and then press the number button 1 This is page number 4 Hold down the number button 1 Thisis number of the page 5 If you press 2 and